Loading...
HomeMy WebLinkAboutNC0027103_Permit Modification_20110314AVA NCDENR North Carolina Department of Environment and Natural Resources Division of Water Quality Beverly Eaves Perdue Coleen H. Sullins _ __.__.._ .__.._._ _ Dee Freeman Governor Director Secretary MAR 1 4 2011 Mr. McDuffie Cummings, Town Manager Town of Pembroke P. O. Box 866 Pembroke, NC 28372 Subject: NPDES Permit Modification Permit Number NC0027103 Town of Pembroke WWTP Robeson County Dear Mr. Cummings: Division personnel have reviewed and approved your application for minor modification of the subject permit. Accordingly we are forwarding the attached modified permit page. Please remove the existing "Effluent Limitations And Monitoring Requirements" page and replace it with the one attached to this letter. This modification removes the effluent monitoring requirement for cadmium. The modification was based upon the following factors: 1) your statement that the flow to the WWTP is 100% domestic, with no contributions from industrial discharges, and 2) a reasonable potential analysis based upon effluent data submitted by the facility was conducted, which showed the discharge exhibited no reasonable potential to cause the water quality standard for cadmium to be exceeded in the receiving stream. This modification is issued pursuant to the requirements of North Carolina General Statute 143-215.1 and the Memorandum of Agreement between North Carolina and the U.S. Environmental Protection Agency dated October 15, 2007 (or as subsequently amended). Please note that this permit is not transferable except after notice to the Division. The Division may require modification or revocation and reissuance of the permit. This permit does not affect the legal requirements to obtain other permits which may be required by the Division of Water Quality or permits required by the Division of Land Resources, the Coastal Area Management Act or any other Federal or Local governmental permit that may be required. If you have any questions concerning this permit, please contact Bob Sledge at telephone number (919) 807-6398 or via e-mail at bob.sledge@ncdenr.gov. cerely, )1(. (.1`)d. Coleen H. Sullins cc: Central Files Fayetteville Regional Office/Surface Water Protection Section NPDES Permit File ec: Aquatic Toxicology Unit EPA Region 4 — Pamela Myers 1617 Mail Service Center, Raleigh, North Carolina 27699-1617 Location: 512 N. Salisbury St: Raleigh, North Carolina 27604 Phone: 919-807-6300 \ FAX: 919-807-6492 \ Customer Service: 1-877-623-6748 Internet: www.ncwaterquality.org An Equal Opportunity i Affirmative Action Employer NoprthCarolina Naturally Permit NC0027103 A. (1.) EFFLUENT LIMITATIONS AND MONITORING REQUIREMENTS During the period beginning on the effective date of this permit and lasting until expiration, the permittee is authorized to discharge from outfall 001. Such discharges shall be limited and monitored by the Permittee as specified below: EFFLUENT CHARACTERISTICS LIMITS MONITORING REQUIREMENTS Monthly Average Weekly Average Daily Maximum Measurement Frequency Sample Type Sample Location Flow 1.33 MGD Continuous Recording Influent or Effluent Temperature, °C Daily Grab Effluent Temperature, °C (June 1 - September 30) 3/Week Grab Upstream Et Downstream Temperature, °C (October 1 - May 31) WeeklyGrab Upstream Et 1 Downstream BOD, 5-day, 20° C 2 18.0 mg/L 27.0 mg/L 3/Week Composite Influent Et Effluent Total Suspended Solids (TSS) 2 20.0 mg/L 30.0 mg/L 3/Week Composite Influent Et Effluent Ammonia as Nitrogen (NH3-N) 12.0 mg/L 35.0 mg/L 3/Week Composite Effluent Dissolved Oxygen (DO) Not less than 5.0 mg/L daily average 3/Week Grab Effluent Dissolved Oxygen, mg/L (DO) (June 1 - September 30) 3/Week Grab Upstream Et Downstream 1 Dissolved Oxygen, mg/L (DO) (October 1 - May 31) WeeklyGrab Upstream Et 1 Downstream Fecal Coliform (Geometric mean) 200/100 ml 400/100ml 3/Week Grab Effluent pH Not more than 9.0 S.U. nor less than 6.0 S.U. 3/Week Grab Effluent Total Residual Chlorine 3 28 pg/L 3/Week Grab Effluent Total Kjeldahl Nitrogen (TKN) Monitor and Report, mg/L Monthly Composite Effluent Nitrite/Nitrate Nitrogen (NO2-N + NO3-N) Monitor and Report, mg/L Monthly Composite Effluent Total Nitrogen (TN) TN = (NO2-N + NO3-N) + TKN Monitor and Report, mg/L Monthly Calculated Effluent Total Phosphorus (TP) Monitor and Report mg/L Monthly Composite Effluent Chronic Toxicity 4 Quarterly Composite Effluent Pollutant Analysis 5 Annually Composite Effluent Footnotes: 1. Sample locations: Upstream = CSX R.R. Trestle (above plant), Downstream = at Bridge SR 1554. 2. The monthly average effluent BOD5 and Total Suspended Solids concentrations shall not exceed 15 percent of the respective monthly average influent value (85% removal). 3. Total Residual Chlorine compliance is required for chlorine or chlorine derivative used for disinfection. The Division shall consider all effluent TRC values reported below 50 ug/l to be in compliance with the permit. However, the Permittee shall continue to record and submit all values reported by a North Carolina certified laboratory (including field certified), even if these values fall below 50 ug/l. 4. Chronic Toxicity (Ceriodaphnia) P/F at 1.7%; January, April, July, and October. See Special Condition A.(2.) of this permit. Quarterly sampling shall be conducted at the same time as metal and other effluent parameters sampling is conducted. 5. See Condition A. (3.) of this permit. There shall be no discharge of floating solids or visible foam in other than trace amounts. Town of Pembroke POST OFFICE BOX 866 PEMBROKE, NORTH CAROLINA 28372 MILTON R. HUNT MAYOR McDUFFIE CUMMINGS MANAGER AMIRA HUNT CLERK NCDENR/Division of Water Quality NPDES Surface Water Protection Section 1617 Mail Service Center Raleigh, NC 27699-16147 Dear Surface Water Protection Section: COUNCILMEN: LARRY BROOKS LARRY McNEILL GREGORY CUMMINGS ALLEN G. DIAL The Town of Pembroke is requesting a minor permit modification of NPDES Permit NC0027103. The Town of Pembroke wishes to remove cadmium as a monthly monitoring requirement. The current permit went into effect October, 2009. Since that time Pembroke has performed 14cadmium analyses that were all less than the detection level. In fact all cadmium analyses dating back to 2005 have been below detection. Our waste stream is 100% domestic and we have no industrial dischargers. In light of the above data we are requesting that the cadmium monitoring be removed. Over the life of the permit approximately $3400 could be allocated to maintenance or the purchase of new equipment, which is vital to daily wastewater treatment, especially small systems. The current economy has forced Pembroke to search all avenues for efficiency and still fulfill all obligations. The Town of Pembroke appreciates your cooperation and anticipates that together we can protect public health and the environment. Please contact Rhonda Locklear at 910-521-2989 if you have any questions. Sincerely, r rM u e Cfit; ummings DENR-WAi ER QUALITY POINT. SOURCE BRANCH Town of Pembroke WWTP Cadmium Data 10/2009 - 11/2010 Permit Version Facility County Region Outfall Month Day Year Comment Parameter Param Class Sample UoM Value Modifier Cell Type Lon Subbasin NC0027103 3.00 Town of Pembroke - Pembroke WWTP Robeson Fayetteville 001 10 9 2009 01027- Cadmium, Total (as Cd) Metal Grab ugA 1. LESSTHAN DLYVALUE Effluent 03-07-51 NC0027103 3.00 Town of Pembroke - Pembroke WWTP Robeson Fayetteville 001 11 23 2009 01027- Cadmium, Total (as Cd) Metal Grab ug/I 1. LESSTHAN DLYVALUE Effluent 03-07-51 NC0027103 3.00 Town of Pembroke - Pembroke WWTP Robeson Fayetteville 001 12 2 2009 01027- Cadmium, Total (as Cd) Metal Grab ug/I 1. LESSTHAN DLYVALUE Effluent 03-07-51 NC0027103 3.00 Town of Pembroke - Pembroke WWTP Robeson Fayetteville 001 1 8 2010 01027- Cadmium, Total (as Cd) Metal Grab ug/I 1. LESSTHAN DLYVALUE Effluent 03-07-51 NC0027103 3.00 Town of Pembroke - Pembroke WWTP Robeson Fayetteville 001 2 17 2010 01027 - Cadmium, Total (as Cd) Metal Grab ugA 1. LESSTHAN DLYVALUE Effluent 03-07-51 NC0027103 3.00 * Town of Pembroke - Pembroke WWTP Robeson Fayetteville 001 3 1 2010 01027 - Cadmium, Total (as Cd) Metal Grab ug/I 1. LESSTHAN DLYVALUE Effluent 03-07-51 NC0027103 3.00 Town of Pembroke - Pembroke WWTP Robeson Fayetteville 001 4 7 2010 01027- Cadmium, Total (as Cd) Metal Grab ug/I 1. LESSTHAN DLYVALUE Effluent 03-07-51 NC0027103 3.00 Town of Pembroke - Pembroke WWTP Robeson Fayetteville 001 5 5 2010 01027 - Cadmium, Total (as Cd) Metal Calculated ug/I 1. LESSTHAN DLYVALUE Effluent 03-07-51 NC0027103 3.00 Town of Pembroke - Pembroke WWTP Robeson Fayetteville 001 6 9 2010 01027- Cadmium, Total (as Cd) Metal Grab ug/I 1. LESSTHAN DLYVALUE Effluent 03-07-51 NC0027103 3.00 Town of Pembroke - Pembroke WWTP Robeson Fayetteville 001 7 6 2010 01027- Cadmium, Total (as Cd) Metal Grab ug/I 1. LESSTHAN DLYVALUE Effluent 03-07-51 NC0027103 3.00 Town of Pembroke - Pembroke WWTP Robeson Fayetteville 001 8 2 2010 01027 - Cadmium, Total (as Cd) Metal Grab ug/I 1. LESSTHAN DLYVALUE Effluent 03-07-51 NC0027103 3.00 Town of Pembroke - Pembroke WWTP Robeson Fayetteville 001 9 14 2010 01027 - Cadmium, Total (as Cd) Metal Grab ug/I 1. LESSTHAN DLYVALUE Effluent 03-07-51 NC0027103 3.00 Town of Pembroke - Pembroke WWTP Robeson Fayetteville 001 10 5 2010 01027 - Cadmium, Total (as Cd) Metal Grab ug/I 1. LESSTHAN DLYVALUE Effluent 03-07-51 NC0027103 3.00 Town of Pembroke - Pembroke WWTP Robeson Fayetteville 001 11 23 2010 01027 - Cadmium, Total (as Cd) Metal Grab ug/I 1. LESSTHAN DLYVALUE Effluent 03-07-51 ciatow POST OFFICE BOX 866 PEMBROKE, NORTH CAROLINA 28372 OFFICE OF THE MANAGER March 30, 2010 Point Source Branch Surface Water Protection Section Division of Water Quality 1617 Mail Service Center Raleigh, NC 27699-1617 Subject: Delegation of Signature Authority Town of Pembroke Wastewater Treatment Plant NPDES No. NC0027103 To Whom It May Concern: MUNICIPAL BUILDING 100 SOUTH UNION CHAPEL ROAD APR 12010 POINT Ou�,t.; _,rry / N 4 By notice of this letter, I hereby delegate signatory authority to each of the following individuals for all permit applications, discharge monitoring reports, and other information relating to the operations at Town of Pembroke Wastewater Treatment Plant as required by all applicable federal, state, and local environmental agencies specifically with the requirements for signatory authority as specified in 15A NCAC 2B.0506. Rhonda Hagan Locklear Water and Wastewater Director If you have any questions regarding this letter, please feel free to contact me at 910-521- 9758. Sincerely, Mc uffie Cummin cc: Fayetteville Regional Office, Surface Water Protection Section Technical Assistance and Certification Unit PHONE (910) 521-9758 • FAX (910) 521-0472 E-MAIL: MCDUFFIE@PEMBROKENC.COM TOWN OF PEMBROKE PO BOX 866 PEMBROKE NC 28372 91 0-521 -9758 (PHONE) 91 0-52 1 -0472 (FAX) TRANSMITTAL SHEET TO: FROM: Michelle Scott McDuffle Cummings COMPANY DATE: DIVISION OF WATER QUALITY 03-31-2010 REFERENCE: Delegation of Signature Authority Per your request. Please feel free to call if you have additional questions. SHEETS: