HomeMy WebLinkAboutSW6220904_Plansheet - Other_202211021/2" Q
EIR I
1
1
I
1
1
I
1
1
1
1
I
1
VICINITY MAP
1
\
1
N/F
\ OT TO SCALE
\�
HENRY BROWN
DB 107, PG 330
\
\
I
2 1/2" EIP 1
\
LEANING
\ ERS 1 "ANGLE
J IRON
N/F
PAUL W. WILKES & WIFE,
HEDI J. WILKES
DB 688, PG 459
_ r
_ � 1
32
U��11
INV ^/1
323.9 / I
1
N/F I
ARNOLD R. BOWEN & WIFE,
SYLVIA G. BOWEN
DB 262, PG 473 1
1
I
1
1
1
1 -
I '
1
,ECM WITHI
1" EIP 1
1/2°Y\
EIP 1 ERS
1
N/F I
RICHARD L. MUMMA JR. & WIFEI
SHARON D. MUMMA 1
DB 834, PG 150 I
o�
>- U
Q J
� m
O a
J �
J �
U
j I
IECS 1
1 LRJ
1
I
1
1
I
1
1
I ECG
EPK
Know what's below.
Call before you dig.
LEGEND:
PK 0 PK—PK NAIL
ECMZ ECM —EXISTING CONCRETE MONUMENT
EIP (0 EIP—EXISTING IRON PIPE
EIR OO EIR—EXISTING IRON ROD
EIS O EIS —EXISTING IRON STAKE
EPKO EPK—EXISTING PK NAIL
ECSO ECS—EXISTING COTTON SPINDLE
SPKO SPK—SET PK NAIL
C COMPUTED POINT
N/F — NOW OR FORMERLY
R/W — RIGHT OF WAY
RCP — REINFORCED CONCRETE PIPE
PROPERTY LINE
ADJACENT PROPERTY LINE
TIE LINE
RIGHT—OF—WAY
11GT UNDERGROUND TELEPHONE LINE
// OVERHEAD UTILITY
X FENCE LINE
TREE LINE
325 MAJOR CONTOUR
322 MINOR CONTOUR
x 329.34' SPOT ELEVATION
BENCHMARK
MB MAILBOX
pp UTILITY POLE
0 TELEPHONE PEDESTAL
FIRE HYDRANT
0 WATER METER
ASPHALT
SOIL
UNSUITABLE SOILS
PROPOSED FIRE HYDRANT
0 PROPOSED WATER METER
4 PROPOSED BALL VALVE
TH PROPOSED TAP SLEEVE AND VALVE
T . PROPOSED BLOW OFF
[ 1 PROPOSED TEE
�—/ PROPOSED 22.5- BEND
�— PROPOSED 11.25- BEND
PROPOSED PLUG
N/F
SHAUNNA MARIE DUNLAP
DB 661, PG 763
\��u
UTILITY NOTES
1. THE CONTRACTOR SHALL MAINTAIN A SET OF RED LINE AS—BUILTS
DURING THE CONSTRUCTION OF THE WATER LINE. ALL DEVIATIONS
FROM THE PLAN SHALL BE NOTED ON THE AS —BUILT DRAWINGS. ALL
VALVES AND CHANGE IN DIRECTION OF THE WATER LINE SHALL BE
LOCATED WITH A MINIMUM OF TWO DISTANCES FROM A KNOWN
OBJECT. THE CONTRACTOR WILL PROVIDE THE AS —BUILT DRAWINGS
TO THE OWNER TO BE USED FOR THE WATER LINE CERTIFICATION AT
THE COMPLETION OF THE PROJECT.
2. HORIZONTAL DIMENSIONS GIVEN FOR UNDERGROUND UTILITY TIES ARE
APPROXIMATE UNLESS OTHERWISE NOTED.
3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR CONTACTING ALL
UTILITY COMPANIES AFFECTED BY THE PROPOSED WORK.
4. THE GENERAL CONTRACTOR SHALL OBTAIN ALL NECESSARY PERMITS
TO COMPLETE THE PROPOSED WORK, AND SHALL COMPLY WITH ALL
LOCAL, STATE, AND FEDERAL REGULATIONS
5. PIPE SHALL BE LAID UPSTREAM WITH THE SPIGOT ENDS POINTING
DOWNSTREAM. ALL PIPES SHALL BE PLACED TRUE TO LINE AND
GRADE WITH ENDS ABUTTING, CAREFULLY CENTERED, AND WITH A
SMOOTH INVERT AT THE JOINT.
6. MINIMUM SEPARATION BETWEEN SEWER (STORM OR SANITARY) AND
WATER LINES SHALL BE 10' HORIZONTAL OR 18" VERTICAL UNLESS
NOTED OTHERWISE. MINIMUM VERTICAL SEPARATION BETWEEN
SANITARY SEWER AND STORM SEWER SHALL BE 24" UNLESS NOTED
OTHERWISE.
7. ALL MAINS, LATERALS AND APPURTENANCES SHALL BE TESTED IN
ACCORDANCE WITH HOKE COUNTY PUBLIC WORKS AND NCDEQ
TECHNICAL SPECIFICATIONS.
8. ALL MATERIALS SHALL BE APPROVED BY HOKE COUNTY PUBLIC
WORKS BEFORE INSTALLATION.
9. THE CONTRACTOR SHALL NOTIFY THE ENGINEER OF RECORD AND
HOKE COUNTY PUBLIC WORKS A MINIMUM OF 48 HOURS BEFORE
CONSTRUCTION OF THE WATER LINE BEGINS. THE CONTRACTOR
N/F
ELIZABETH MARIE DAYTON—FRUM
DB 1178, PG 995
/r \I .�� \1�
SHALL ALSO NOTIFY THE ENGINEER OF RECORD AND HOKE COUNTY
PUBLIC WORKS 48 HOURS IN ADVANCE OF ALL TESTING.
10. EXISTING UTILITIES NOT FOUND IN THE FIELD DURING SURVEY MAY
REQUIRE DEMOLITION. NO UTILITIES SHALL BE LEFT IN PLACE THAT
CROSS THE NEW LOTS UNLESS RUNNING ALONG A LOT LINE. IF
ADDITIONAL UTILITIES ARE FOUND, CONTACT ENGINEER PRIOR TO
DEMOLITION.
11. ALL ELEVATIONS ARE IN NAVD 88 DATUM.
12. ALL UTILITY STRUCTURES SHALL BE LOAD RATED FOR THE
APPROPRIATE DEAD LOAD PLUS HL-93 LIVE LOAD. SUCH
STRUCTURES SHALL BE DESIGNATED AND CERTIFIED BY A LICENSED
PE OR DESIGNATED AS MEETING NCDOT STANDARD SPECIFICATIONS
AND DRAWINGS.
13. ELECTRICAL POWER AND COMMUNICATIONS FACILITIES SHOULD
CONFORM TO THE CURRENTLY APPLICABLE NATIONAL ELECTRICAL
SAFETY CODE EXCEPT VERTICAL CLEARANCES SHALL BE NO LESS
THAN 18 FEET IN ANY CASE.
14. ALL NON—FERROUS PIPELINES SHALL BE INSTALLED WITH A
LOCATING TAPE.
*PUBLIC SEWER NOT AVAILABLE.
SEWAGE WILL BE TREATED BY
SEPTIC SYSTEMS ON INDIVIDUAL
LOTS.
3
N/F
DARNELL & JANET MORGAN
DB 274, PG 540
PC 2-74, MAP 4
NC GRID NAD 83 (2011)
I
I
I
I
HERBB l
N/F
CAROLYN JEAN LEWIS
DB 161, PG 403
1 \
GRAPHIC SCALE
( IN FEET )
1 inch = 100 ft.
A
N/F
PATRICK J. SIMPSON & WIFE,
KARA SIMPSON
DB 1018, PG 839
PC 3-82, MAP 2
400
4Dsite
solutions
civil engineering I land surveying
409 Chicago Drive, Suite 112, Fayetteville, NC 28306
office 1910-426-6777 fax 1910-426-5777 license number I C-2354
wwwAD site solutions.com
.•••• ••.
•% `9 i
• 4� SEA
• 0274
CC)1 1111g���```
08-U"i-.2.2
REVISIONS
PROJECT NAME
HIDDEN
VALLEY
SUBDIVISION
OVERALL UTILITY
PLAN
PIN: 584950001083
CLIENT
TG VENTURES LLC
9820 US Hwy 301 North
Lumberton, North Carolina 28360
Phone: (910) 802-4959
PROJECT INFORMATION
DESIGNED BY:
BRETT
DRAWN BY:
BRETT
CHECKED BY:
SCOTT
PROJECT NUMBER:
1860
DRAWING SCALE
HORIZONTAL: 1 "=100'
DATE RELEASED
AUGUST 9, 2022
SHEET NUMBER
THE CONTRACTOR MUST CONTACT NORTH CAROLINA ONE CALL CENTER AT 1-800-632-4949 A MINIMUM OF 72 HOURS PRIOR TO DIGGING IN ORDER TO HAVE THE EXISTING UTILITIES LOCATED
C-400