Loading...
HomeMy WebLinkAboutNC0023299_Staff Report_19960110CC: Permits and Engineering Technical Support Branch County Health Dept. Central Files WSRO SOC PRIORITY PROJECT: Yes No X If Yes, SOC No. To: Permits and Engineering Unit Water Quality Section Attention: Jeannette Powell (Review Engineer) Date: 960110 NPDES STAFF REPORT AND RECOMMENDATION County Guilford Permit No. NC0023299 PART I - GENERAL INFORMATION 1. Facility and Address: Ms. Barbara Norcom, Director of Operations Oakwood Land Dev. Corp. 7025 Albert Pick Rd. Suite 301 Greensboro, NC 27409 2. Date of Investigation: 960110 3. Report Prepared by: Ron Linville 4. Persons Contacted and Telephone Number: Richard Jenkins 910/656-7100 Barbara Norcom 910/855-2526 5. Directions to Site: From Greensboro I-85/40 take Randleman Rd south then left on Sheraton Park Rd. WWTP will be on left approx. 3/4 mile just before large lake. 6. Discharge Points(s), List for all discharge points: Latitude: 35058'12" Longitude: 79047'43" U.S.G.S. Quad No. D19NE U..S.G.S.,Quad Name Pleasant Gdn. 7. Site size and expansion area consistent with application ? X Yes No If No, explain: 8. Topography (relationship to flood plain included): Not in floodplain but adjacent to discharge from lake. 9. Location of nearest dwelling: None known within 1000'. 10. Receiving stream or affected surface waters: UT Polecat Creek a. Classification: WS-III b. River Basin and Subbasin No: CPF 0306 c. Describe receiving stream features and pertinent downstream uses: Stream has very little flow during dry weather and has a history of appearing black and having eutrophic conditions probably from solids escaping the WWTP. Mats of material and bubbles are often observed arising from the bottom of the stream near the WWTP. Noxious conditions have been alleviated by stream pumping by the ORC at the direction of the Permittee. Part II DESCRIPTION OF DISCHARGE AND TREATMENT WORKS 1. a. Volume of Wastewater to be permitted: 0.070 MGD (Ultimate Design Capacity) b. What is the current permitted capacity of the Waste Water Treatment facility? Same. c. Actual treatment capacity of the current facility (current design capacity)? 0.070 MGD with sandfilters activated. d. Date(s) and construction activities allowed by previous Authorizations to Construct issued in the previous two years. A2C issued in March, 1994 for construction of dual tertiary sand filters and a UV disinfection unit. The Region understands that the above construction has been postponed until a determination has been made as to a possible connection to a POTW in Greensboro. e. Please provide a description of existing or substantially constructed wastewater treatment facilities: Extended aeration treatment plant with influent pump station and two parallel aeration systems with diffused aeration, aerated sludge holding tank, continuous flow recorder measuring device and standby power and gas chlorinator. System may not always be operated as a parallel system and old sandfilters are not utilized. f. Please provide a description of proposed wastewater treatment facilities. See A2C above. g Possible toxic impacts to surface waters: BOD concerns and public water supply concerns. NPDES Permit Staff Report Version 10/92 Page 2 h. Pretreatment Program (POTWs only): in development approved • should be required not needed 2. Residuals handling and utilization/disposal scheme: a. If residuals are being land applied, please specify DEM Permit No. NA . Residuals Contractor: Richard Jenkins Telephone No. Same as above. b. Residuals stabilization: PSRP PFRP Other c. Landfill: d. Other died tolPOTWlination GreensboroeasSneeded): Pumped and ha 3. Treatment plant classification (attach completed rating sheet). II 4. SIC Code(s) : 6515 Primary 08 Secondary _ Main Treatment Unit Code: 060 8 PART III - OTHER PERTINENT INFORMATION. 1. Is this facility being constructed with Construction Grant Funds or are any public monies involved. (municipals only)? 2. Special monitoring or limitations (including toxicity) requests: None. 3. Important SOC, JOC or Compliance Schedule dates: (Please indicate) Submission of Plans and Specifications Begin Construction Complete Construction 4. Alternative Analysis Evaluation: Has the facility evaluated all of the non -discharge options available. Please provide regional perspective for each option evaluated. Date NPDES Permit Staff Report Version 10/92 Page 3 Spray Irrigation: Not enough land withoututilizing developable, property. Connection to Regional Sewer System: Connection is being pursued by Oakwood and may be possible within three years. Subsurface: Not enough land without using developable property. Other disposal options: 5. Other Special Items: Associated creek conditions are not good and complaints have been investigated by the WSRO due to the water supply concerns. Recommend that the Water Supply Section also be allowed to comment on this discharge as well as the City of Randleman. An alternatives analysis was submitted to the Division on October 12, 1993. This alternatives study should be reevaluated prior to Dec. 31, 1996 due to- the enhanced potential for public sewer in the Pleasant Garden community and reported recent discussions between the City of Greensboro and Oakwood Land Development Corp (owners of the Woodlake MHP WWTP). Conditions in the creek may be somewhat due to low flows during summer months and backed up waters; however, the Region still believes that solids are likely to be escaping into the stream from time to time. PART IV - EVALUATION AND RECOMMENDATIONS The WSRO recommends that the permit be reissued with a stipulation that the sandfilters and ultraviolet disinfection be installed withintwo years of permit issuance or connect to the public sewer. The facility should also be required to connect to the POTW.within 180 days of economically feasible availability regardless of any upgrades. This recommendation is based on Part II Section B.2. and Section 4.13. of the existing NPDES Permit. S}rgnature of report preparer -7 QualitRegional Supervisor e NPDES Permit Staff Report Version 10/92 / 99,6 Page 4 11 ' At-4E a 859, \--ZV7 1 vilTs a 8: