Loading...
HomeMy WebLinkAboutWQ0043896_Final Permit_20221104WGLA Engineering WGLA Engineering, PLLC 724 5th Avenue West Hendersonville, NC 28739 (828) 687-7177 wgla.com November 2, 2022 Mr. Tim Heim, P.E. Water Quality Section NCDEQ 2090 US Highway 70 Swannanoa, North Carolina 28778 RE: City of Hendersonville Judges Tract Sewer Extension Dear Mr. Heim: 303 NUV " 3 2022 Water Quality Regional Operations Asheville Regional Office Please find enclosed a submittal package for the proposed sewer extension to serve a future development adjacent to Interstate 26. Note this is a zero flow extension as there is not a specific user identified for the property. The line is being installed in conjunction with a proposed access road. This is a proposed extension of the City of Hendersonville system. In addition to the completed fast track application (original and one copy), the following items are included with this letter: -application fee of $480.00 -site maps Note that we have not included a flow tracking form since there is no flow associated with this application. If you have any questions or need additional information, don't hesitate to contact our office. Sincerely, WGLA Engineering, PLLC William R. Buie, P.E. CIVIL ENGINEERS & LAND PLANNERS - Wild `6uuaau!6u3 V1OM O ) co .0-19E040.11 0 W 0 0 0 0 au 0 0 Lfl FP r 9-` e -� r" EP O pdl-r -.1//2 oww Security features. Details on bank. DocuSign Envelope ID: C3028C46-ED2C-4858-8B50-93973D0A886A DWR Division of Water Resources State of North Carolina Department of Environmental Quality Division of Water Resources 15A NCAC 02T .0300 — FAST TRACK SEWER SYSTEM EXTENSION APPLICATION FTA 04-16 & SUPPORTING DOCUMENTATION Application Number: (to be completed by DWR) All items must be completed or the application will be returned I. APPLICANT INFORMATION: 1. Applicant's name: City of Hendersonville Water and Sewer Department (company, municipality, HOA, utility, etc.) 2. Applicant type: ❑ Individual ❑ Corporation El General Partnership ❑ Privately -Owned Public Utility 0 Federal 0 State/County ® Municipal 3. Signature authority's name: Lee Smith per 15A NCAC 02T .0106(b) Title: Utilities Director 4. Applicant's mailing address: 305 Williams Street City: Hendersonville State: NC Zip: 28792- 5. Applicant's contact information: Phone number: (828) 697-3073 Email Address: lsmith@hvinc.gov II. PROJECT INFORMATION: 1. Project name: Judges Tract Sewer Extension 2. Application/Project status: ® Proposed (New Permit) ❑ Existing Permit/Project If a modification, provide the existing permit number: WQ00 and issued date: If new construction but part of a master plan, provide the existing permit number: WQ00 3. County where project is located: Henderson 4. Approximate Coordinates (Decimal Degrees): Latitude: 35.301°Longitude: -82.412° 5. Parcel ID (if applicable): 9558-22-1126 (or Parcel ID to closest downstream sewer) III. CONSULTANT INFORMATION: 1. Professional Engineer: William R. Buie License Number: 022989 Firm: WGLA Engineering, PLLC Mailing address: 724 5th Avenue West City: Hendersonville State: NC Zip: 28739- Phone number: (828) 687-7177 Email Address: wbuie@wgla.com IV. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION: 1. Facility Name: Hendersonville WWTP Permit Number: NC0025534 Owner Name: City of Hendersonville V. RECEIVING DOWNSTREAM SEWER INFORMATION (if different than WWTF): 1. Permit Number(s): WQ Downstream (Receiving) Sewer Size: inch System Wide Collection System Permit Number(s) (if applicable): WQCS Owner Name(s): 0 Other 73c3.7, NU V 3 1011 r! Water Quality Regional Operations Asheville Regional Office FORM: FTA 04-16 Page 1 of 5 DocuSign Envelope ID: C3028C46-ED2C-4858-8B50-93973D0A886A VI. GENERAL REQUIREMENTS 1. If the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached? ❑ Yes ❑No ®N/A 2. If the Applicant is a Developer of lots to be sold, has a Developer's Operational Agreement (FORM: DEV) been attached? ❑ Yes ❑No ®N/A 3. If the Applicant is a Home/Property Owners' Association, has an Operational Agreement (FORM: HOA) been attached? ❑ Yes ❑No ®N/A 4. Origin of wastewater: (check all that apply): ❑ Residential Owned ❑ Retail (stores, centers, malls) ❑ Residential Leased ❑ Retail with food preparation/service ❑ School / preschool / day care ❑ Medical / dental / veterinary facilities 111 Food and drink facilities ❑ Church ❑ Businesses / offices / factories ❑ Nursing Home ❑ Car Wash ❑ Hotel and/or Motels ❑ Swimming Pool /Clubhouse ❑ Swimming Pool/Filter Backwash ® Other (Explain in Attachment) 5. Nature of wastewater : 100 % Domestic/Commercial % Commercial % Industrial (See 15A NCAC 02T .0103(20)) >Is there a Pretreatment Program in effect? ❑ Yes ❑ No 6. Has a flow reduction been approved under 15A NCAC 02T .0114(f)? ❑ Yes ❑ No ➢ If yes, provide a copy of flow reduction approval letter 7. Summarize wastewater generated by project: Establishment Type (see 02T.0114(f)) Daily Design Flow a,b No. of Units Flow Sewer line is for future development gal/ 0 GPD gal/ GPD gal/ GPD gal/ GPD gal/ GPD gal/ GPD Total 0 GPD a See 15A NCAC 02T .0114(b), (d), (e)(1) and (e)(2) for caveats to wastewater design flow rates (i.e., minimum flow per dwelling; proposed unknown non-residential development uses; public access facilities located near high public use areas; and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in G.S. 42A-4). b Per 15A NCAC 02T .0114(c), design flow rates for establishments not identified [in table 15A NCAC 02T.0 114] shall be determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data. 8. Wastewater generated by project: 0 GPD (per 15A NCAC 02T .0114) ➢ Do not include future flows or previously permitted allocations If permitted flow is zero, indicate why: ❑ Pump Station or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line ❑ Flow has already been allocated in Permit Number: ❑ Rehabilitation or replacement of existing sewer with no new flow expected ❑ Other (Explain): FORM: FTA 04-16 Page 2 of 5 DocuSign Envelope ID: C3028C46-ED2C-4858-8B50-93973D0A886A VII. GRAVITY SEWER DESIGN CRITERIA (If Applicable) - 02'F .0305 & MDC (Gravity Sewers): 1. Summarize gravity sewer to be permitted: Size (inches) Length (feet) Material 8 205 PVC/SDR-35 8 244 DIP > Section II & III of the MDC for Permitting of Gravity Sewers contains information related to design criteria ➢ Section III contains information related to minimum slopes for gravity sewer(s) ➢ Oversizing lines to meet minimum slope requirement is not allowed and a violation of the MDC VIII. PUMP STATION DESIGN CRITERIA (If Applicable) — 02T .0305 & MDC (Pump Stations/Force Mains): COMPLETE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT 1. Pump station number or name: 2. Approximate Coordinates (Decimal Degrees): Latitude: . Longitude: - . 3. Design flow of the pump station: 4. Operational point(s) of the pump(s): millions gallons per day (firm capacity) gallons per minute at 5. Summarize the force main to be permitted (for this Pump Station): feet total dynamic head (TDH) Size (inches) Length (feet) Material 6. Power reliability in accordance with I5A NCAC 02T .0305(h)(1): ❑ Standby power source or pump with automatic activation and telemetry - 15A NCAC 02T .0305(h)(1)(B): ➢ Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day ➢ Must be permanent to facility Or if the pump station has an average daily flow Less than 15,000 gallons per day: ❑ Portable power source with manual activation, quick -connection receptacle and telemetry - 15A NCAC 02T .0305(h)(1)(C) or ❑ Portable pumping unit with plugged emergency pump connection and telemetry - 15A NCAC 02T .0305(h)(1)(C): ➢ It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant (draft agreement) and is compatible with the station. > If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided in the case of a multiple station power outage. FORM: FTA 04-16 Page 3 of 5 DocuSign Envelope ID: C3028C46-ED2C-4858-8B50-93973D0A886A IX. SETBACKS & SEPARATIONS — (02B .0200 & 15A NCAC 02T .0305(0): 1. Does the project comply with all separations found in 15A NCAC 02T .0305(f) & (g) ➢ 15A NCAC 02T.0305(f) contains minimum separations that shall be provided for sewer systems: ® Yes ❑ No Setback Parameter* Separation Required Storm sewers and other utilities not listed below (vertical) 24 inches Water mains (vertical -water over sewer including in benched trenches) 18 inches Water mains (horizontal) 10 feet Reclaimed water lines (vertical - reclaimed over sewer) 18 inches Reclaimed water lines (horizontal - reclaimed over sewer) 2 feet **Any private or public water supply source, including any wells, WS-I waters of Class I or Class II impounded reservoirs used as a source of drinking water 100 feet **Waters classified WS (except WS-I or WS-V), B, SA, ORW, HQW, or SB from normal high water (or tide elevation) and wetlands (see item IX.2) 50 feet **Any other stream, lake, impoundment, or ground water lowering and surface drainage ditches 10 feet Any building foundation 5 feet Any basement 10 feet Top slope of embankment or cuts of 2 feet or more vertical height 10 feet Drainage systems and interceptor drains 5 feet Any swimming pools 10 feet Final earth grade (vertical) 36 inches > 15A NCAC 02T.0305(g) contains alternatives where separations in 02T.0305(f) cannot be achieved. ➢ **Stream classifications can be identified using the Division's NC Surface Water Classifications webpage > If noncompliance with 02T.0305(f) or (g), see Section X of this application 2. Does the project comply with separation requirements for wetlands? (50 feet of separation) ❑ Yes ❑ No ® N/A ➢ See the Division's draft separation requirements for situations where separation cannot be meet > No variance is required if the alternative design criteria specified is utilized in design and construction > As built documents should reference the location of areas effected 3. Does the project comply with setbacks found in the river basin rules per 15A NCAC 02B .0200? ❑ Yes ❑ No ® N/A > This would include Trout Buffered Streams per 15A NCAC 2B.0202 4. Does the project require coverage/authorization under a 404 Nationwide or individual permits or 401 Water Quality Certifications? > Information can be obtained from the 401 & Buffer Permitting Branch III Yes ®No 5. Does project comply with 15A NCAC 02T.0105(c)(6) (additional permits/certifications)? ® Yes ❑ No Per 15A NCAC 02T.0105(c)(6), directly related environmental permits or certification applications are being prepared, have been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent permits (erosion and sedimentation control plans, stormwater management plans, etc.). 6. Does this project include any sewer collection lines that are deemed "high -priority?" Per 15A NCAC 02T.0402, "high -priority sewer" means "any aerial sewer, sewer contacting surface waters, siphon, or sewer positioned parallel to streambanks that is subject to erosion that undermines or deteriorates the sewer. ❑ Yes ® No ❑ N/A > If yes, include an attachment with details for each line, including type (aerial line, size, material, and location). High priority lines shall be inspected by the permittee or its representative at least once every six -months and inspections documented per 15A NCAC 02T.0403(a)(5) or the permitee's individual System -Wide Collection permit. FORM: FTA 04-16 Page 4 of 5 DocuSign Envelope ID: C3028C46-ED2C-4858-8B50-93973D0A886A X. CERTIFICATIONS: 1. Does the submitted system comply with 15A NCAC 02T, the Minimum Design Criteria for the Permitting of Pump Stations and Force Mains (latest version), and the Gravity Sewer Minimum Design Criteria (latest version) as applicable? ®Yes ❑No If No, complete and submit the Variance/Alternative Design Request application (VADC 10-14) and supporting documents for review. Approval of the request is required prior to submittal of the Fast Track Application and supporting documents. 2. Professional Engineer's Certification: I William R. Buie, P.E. attest that this application for (Professional Engineer's name from Application Item III.1.) Judges Tract Sewer Extension has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans, specifications, engineering calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains (latest version). Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. NOTE — In accordance with General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000, as well as civil penalties up to $25,000 per violation. North Carolina Professional Engineer's seal, signature, and date: 3. Applicant's Certification per 15A NCAC 02T .0106(b): I, Lee Smith, Utilities Director (Signature Authority's name & title from Application Item I.3.) Judges Tract Sewer Extension has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. I understand that any discharge of wastewater from this non - discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties, injunctive relief, and/or criminal prosecution. I will make no claim against the Division of Water Resources should a condition of this permit be violated. I also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. attest that this application for NOTE — In accordance with General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. Signature: Leeterniti Oct 31,202210:02EDT) Date: Oct 31, 2022 FORM: FTA 04-16 Page 5 of 5 20221031 _FTARev_22111 Final Audit Report 2022-10-31 Created: 2022-10-31 By: Deborah Sholl (dsholl@hvInc.gov) Status: Signed Transaction ID: CBJCHBCAABAAAeEMZdOw09xkUW51vFiJNAZmVperFBP- "20221031 _FTARev_22111 " History n Document created by Deborah Sholl (dsholl@hvInc.gov) 2022-10-31 - 12:05:32 PM GMT E-21 Document emailed to Lee Smith (Ismith@hvinc.gov) for signature 2022-10-31 - 12:07:45 PM GMT t Email viewed by Lee Smith (Ismith@hvinc.gov) 2022-10-31 - 2:01:55 PM GMT aQ Document e-signed by Lee Smith (Ismith@hvinc.gov) Signature Date: 2022-10-31 - 2:02:35 PM GMT - Time Source: server ® Agreement completed. 2022-10-31 - 2:02:35 PM GMT Adobe Acrobat Sign Sewer Layers Gravity Main ♦ Public Gravity Main ♦ Public Force Main ♦ Proposed Gravity Main — • Abandoned Water Layers Fire Hydrants T City Fire Hydrant Water Main — City Water Main — Private Fire Line — Proposed Water Main Abandoned Water Main Road Layers - State Maintained Road __ Non -State Maintained Road CITY OF HENDERSONVILLE UTILITY AVAILABILITY Judges Tract MAY 2022 Judes Tract PIN:'9588-22-1126 Blue Ridge'Fire District Fire Chief:' W Sheehan The City of Hendersonville makes every effort to confirm the accuracy of this information; however, it does not warrant or guarantee that any information provided is accurate or current. rZ:\GIS\Wat Se�wweMD p \WSLGIS-Projects\Water. wer.pAvailability Maps 250 500 750 1,00( GoMaps EbbYAManor zh Existing Sewer Line Zct.•UpwarcisR.'dp�n.Rc/ ...U.p. l Std'CJpw�rd'Rd Upavard'RdU,pwai,d�Rcl�tr}�War d �.Ji poppy'AcresoLr» November 2, 2022 THIS IS NOTASURVEY. All information or data provided, whether subscribed, purchased or otherwise distributed, whether in hard copy or digital media, shall be at the user's own risk. Henderson County makes no warranties or guarantees, including the warranties of merchantability or of fitness for a particular purpose. Map data is not appropriate for, and is not to be used as, a geodetic, legal, or engineering base system. The data is not intended as a substitute for surveyed locations such as can be determined by a registered Public Land Surveyor, and does not meet the minimum accuracy standards of a Land Information System/Geographic Information System Survey in North Carolina (21 NCAC 56.1608). 1:10,045 0 0.075 0.15 0 0.125 0.25 0.3 mi LI 0.5 km