Loading...
HomeMy WebLinkAboutWQ0043418_More Information (Received)_20221103 PA R ' MOJp4ji E N G 1 N E E R 1 N 1 C. 1 2 2 CINEMA DRIVE W I L M I N G T O N , NC 2 8 4 0 3 9 1 0 - 7 9 1 - 6 7 0 7 ( O ) 9 1 0 - 7 9 1 - 6 7 6 0 ( F ) LETTER OF TRANSMITTAL To: NCDENR: PERCS Unit Date 11/2/2022 512 N.Salisbury Street,Suite 925 Raleigh, NC 27604 Re: Covey Commons Low Pressure Sewer resubmittal Attn: Charlie Miller, PE Project No. 16146.PE IWe are sending: ® Originals ®Prints ❑ Shop Drawings ►1 Calculations The following items: ❑ Correspondence ® Plans ® Specifications ® Other as listed below Quantity Date Dwg.No. Description 2 Updated C-5.1 `ECEIVED 2 Updated Exhibit �OV 0J pU2 1 Response Letter NMIPWRINPDES Issue Status: ®For Approval ❑As Requested ❑ Construction ❑Bid ❑ For Your Use ❑ For Review and Comment ❑Approved as Noted ❑ See Remarks Action Taken: ❑ No Exceptions Taken ❑ Make Corrections Noted ❑ Amend&Resubmit ❑ Rejected-See Remarks ❑ Approved as Submitted ❑ Other Remarks: Resubmittal for WQ0043418 Cc: Signed: Tim Clinkscales, PE PLS pARAmouNTE E N G 1 N E E R 1 N G, 1 N C. kaF' EWP d kj?"4 November 1, 2022 vcoavcivaiogb Charlie Miller NCDENR PERCS Unit 512 N. Salisbury Street, Suite 925 Raleigh, NC 27604 RE: Request for Additional Information - Covey Commons Low Pressure Sewer WQ0043418 Dear Charlie, On behalf of Lot 1 Development, we are submitting a response to your comments emailed 7/20/2022. Please find your comments listed below with our response provided in bold. Application/FTSE: 1. In Section VIII (4) you checked that the project requires 401/404 certifications. Please confirm that these certifications are not required for this project. • These are not required for this project Plans: 1. Profile STA 10+35 to 10+55 on Sheet C-5.0 specifies ductile iron pipe to be installed for the section of 3-inch force main under the two 60-inch RCP drainage pipes. It is recommended that you specify some other pipe material, such as C900, due to the limited availability of ductile iron pipe. • Noted,we will work with contractor/CFPUA for acceptable alternative if needed, contractor has ordered the DIP per my understanding 2. Profile STA 10+50 on Sheet C-5.1 is unclear if 18-inches of separation is achieved between the 3-inch sewer line and the 15-inch RCP drainage line. Please add a note or leader that positively identifies that the minimum 18-inches of separation is achieved per 15A NCAC 02T .0305 (f). • A note added to Sheet C-5.1 but the crossing is shown on C-5.0 having the minimum of 18-inches of cover Calculations: 1. It appears that the statistically likely number of pumps on was not used in the flow calculations. The rational method cannot be used in lieu of the statistically likely number of pumps on. Please revise the calculations to account for the 1 2 2 CINEMA D R I V E, W I L M I N G T ❑ N , NC 2 8 4 ❑ 3 PH : ( 9 1 ❑ ) 7 9 1 - 6 7 ❑ 7 F A X : ( 9 1 ❑ ) 7 9 1 - 6 7 6 ❑ PJIPp:NT:E . statistically likely number of pumps to be on. If this results in the system being undersized, you must also revise the application and plans to account for the changes per 15A NCAC 02T .0305 (j)(1). • We have updated for the probability method 2. Each simplex grinder pump shows a discharge flow of 30 gpm and a head of 26.61 ft which appears to be outside of the pump curve. Please modify the calculations such that a possible flow and pump head can be achieved per 15A NCAC 02T .0305 (b)(2). • Revised numbers are provided Thank you for your attention to this matter. If you have any questions regarding any of this information or require additional material, please feel free to call. Thank you for your time and effo Sincerely, Paramounte Engineering,Inc. 1 2 2 CINEMA D R I V E, W I L M I N G T O N . NC 2 B 4 O 3 PH : ( 9 1 ❑ ) 7 9 1 - 6 7 ❑ 7 F A X : ( 9 1 ❑ ) 7 9 1 - 6 7 6 ❑