Loading...
HomeMy WebLinkAbout20141276 Ver 1_Stormwater Info_20141211WITHERS RAVEN EL EROSION CONTROL HOWARD /EMERSON TRACT - COMMERCIAL Cary, North Carolina Prepared For: NORTHWEST COMMUNITY CHURCH 7712 CARPENTER FIRE STATION RD CARY NC 27519 ATTN: MR. JOEL CARPENTER Prepared By: WITHERS & RAVENEL, INC 115 Mad(enan Drive Cary, North Carolina 27511 September 2014 W &R Project No. 02130427 INTRODUCTION The proposed Howard /Emerson Tract development is located at the intersection of Morrisville Parkway and White Oak Church Road in Cary, NC. The proposed development is a church with associated parking and infrastructure. It is less than 24% and is therefore considered low density The site in its existing conditions is approximately 80% wooded with some open space and impervious area. The site is bound by White Oak Church Road to west, Morrisville Parkway to the north and the American Tobacco Trail to the east - all of which are higher than the site. The site drains towards the center and is collected via an unregulated stream feature which exits the site along the southern boundary. The site is comprised of HSG "D" soils. A soils map is provided in the Background Data portion of this report. PLANNED EROSION AND SEDIMENTATION CONTROL PRACTICES 1. TEMPORARY GRAVEL CONSTRUCTION ENTRANCE /EXIT A temporary gravel construction entrance /exit will be installed at the entrance drive to the site to provide a buffer area for construction vehicles to drop their mud and sediment to avoid transporting it onto public roads. 2. SILT FENCE Silt fence will be installed in areas of fill around the perimeter of the site to maintain drainage into temporary diversion ditches. Silt fence will be used in natural outfall areas to prevent any sediment from leaving the site. 3. TEMPORARY DIVERSION DITCH Temporary diversion ditches will be provided to protect work areas from upslope runoff, and to divert sediment -laden water to appropriate traps or stable outlets. 4. PERMANENT DIVERSIONS Permanent diversion swales will be provided to divert water from areas where it is in excess to locations where it can be used or released without erosion or flood damage. 5. TEMPORARY SKIMMER SEDIMENT BASIN A temporary skimmer sediment basins will be installed at the project site to retain sediment on the construction site, and prevent sedimentation in the surrounding area. MAINTENANCE CONSIDERATIONS The church shall be responsible for periodic inspection and maintenance of all temporary erosion control measures and permanent stormwater devices. Any measure that fails to function as intended shall be repaired immediately. SEDIMENT BASINS s: \0159 \0102 \20 - tech \sedtrap.xls Latest Revision: 10/2/2014 7:48 AM Page 1 of 1 = ' PROJECT NAME Northwest Community Church - Commercial DATE September 30, 2014 PROJECT NO 130427 DESIGN PHASE PRELIM CONSTR /X / REVISION / X / RECORD OTHER (SPECIFY) LOCATION Wake County, North Carolina BY DJB CHECKED BY Temporary Sediment Basins Basin Dist. Area Drain. Area Intensity Cc (in /hr) Q10 Required (cfs) Storage Required Avg.Dims. SA (sf) Depth Width Length Bottom Dims. Top Dims. Provided Storage Provided SA (sf) Spillway Flow Depth Weir Width Width I Length Width I Length 1 I 7.88 ac 7.88 ac 0.40 7.08 22.32 I 14,180 cf 7,250 11.5' 40' I 80' 17' I 57' 69' 109' 1 36,800 cf 7,521 1.00' 8.0' s: \0159 \0102 \20 - tech \sedtrap.xls Latest Revision: 10/2/2014 7:48 AM Page 1 of 1 SKIMMER SIZING Calculate Skimmer Size Basin Volume in Cubic Feet Days to Drain* In NC assume 3 days to drain 36,800 Cu.Ft 3 Days Skimmer Size Orifice Radius Orifice Diameter 4.0 Inch 1.6 Inch[es] 3.1 Inch[es] Estimate Volume of Basin Length Width Top of water surface in feet 109 69 Feet VOLUME 48817.5 Cu. Ft. Bottom dimensions in feet 57 17 Feet Depth in feet 11.5 Feet TEMPORARY DIVERSION DITCHES DIVERSION DITCH LINER SUMMARY Permanent Diversion # Total Area (ac) Total Length Begin Elevation End Elevation A Elevation Tc Slope C Intensity Q Depth Shear Liner 1 5.18 1023.0 377.1 357.6 19.5 7.46 0.019 0.55 7.08 20.17 1.23 1.46 Synthetic Mat 2 0.95 256.7 368.7 361.5 7.2 2.22 0.028 0.58 7.08 3.90 0.64 1.12 Straw w/ Net 3 1.95 171.1 368.3 353.9 14.4 1.06 0.084 0.50 7.08 6.90 0.80 4.20 SC250 4 2.90 621.0 376.5 353.9 22.6 3.96 0.036 0.54 7.08 11.09 0.97 2.20 SC250 PERMANENT SWALES DIVERSION DITCH LINER SUMMARY Permanent Total Area Total Begin End A Tc Slope C Intensity Q Depth Shear Liner Diversion # (ac) Length Elevation Elevation Elevation 1 0.27 360.0 377.2 368.3 8.9 3.02 0.025 0.84 7.08 1.61 0.45 0.69 Straw w/ Net 2 0.17 106.0 367.8 362.5 5.3 0.90 0.050 0.76 7.08 0.91 0.36 1.12 Straw w/ Net 3 0.10 135.0 362.6 358.0 4.6 125 0.034 0.62 7.08 0.44 0.27 0.57 Straw w/ Net 4 0.16 220.0 358.0 355.6 2.4 2.83 0.011 0.62 7.08 0.70 0.38 0.26 Straw w/ Net 5 0.29 390.0 360.4 355.6 4.8 4.20 0.012 0.60 7.08 1.23 0.47 0.36 Straw w/ Net 6 0.21 246.0 360.4 355.3 5.1 2.41 0.021 0.68 7.08 1.01 0.40 0.52 Straw w/ Net 7 1.25 273.0 360.5 360.3 0.2 9.45 0.001 0.60 5.9 4.43 0.69 0.03 Straw w/ Net 8 0.40 438.0 360.5 355.2 5.3 4.62 0.012 0.63 7.08 1.78 0.55 0.42 Straw w/ Net 9 0.08 101.0 355.9 355.2 0.7 1.89 0.007 0.77 7.08 0.44 0.36 0.15 Straw w/ Net 10 0.09 64.0 359.0 355.9 3.1 0.62 0.048 0.84 7.08 0.54 0.29 0.88 Straw w/ Net 11 0.11 119.0 362.0 358.0 4.0 1.14 0.034 0.60 7.08 0.47 0.27 0.57 Straw w/ Net 12 0.12 136.0 367.7 361.0 6.7 1.09 0.049 0.60 7.08 0.51 0.28 0.86 Straw w/ Net 13 0.10 100.0 373.1 368.6 4.5 0.89 0.045 0.78 7.08 0.55 0.29 0.81 Straw w/ Net 14 0.02 25.0 371.2 368.6 2.6 0.22 0.104 0.60 7.08 0.08 0.13 0.84 Straw w/ Net 15 0.12 139.0 377.8 369.5 8.3 1.03 0.060 0.60 7.08 0.51 0.30 1.12 Straw w/ Net 16 0.69 103.9 365.5 360.2 5.3 0.88 0.051 0.84 7.08 4.10 0.65 2.07 SC250 17 0.76 125.4 360.2 358.5 1.7 1.69 0.014 0.86 7.08 4.63 0.76 0.64 Straw w/ Net 18 0.61 236.3 371.0 367.5 3.5 2.66 0.015 0.61 7.08 2.63 0.60 0.55 Straw w/ Net 19 0.08 58.2 371.0 367.5 3.5 0.53 0.060 0.57 7.08 0.32 0.23 0.86 Straw w/ Net 20 0.78 211.5 371.0 367.3 3.7 2.29 0.017 0.61 7.08 3.37 0.65 0.71 Straw w/ Net 21 0.26 283.9 383.8 370.0 13.8 1.94 0.049 0.58 7.08 1.07 0.38 1.15 Straw w/ Net 22 0.12 317.4 385.0 372.4 12.6 2.28 0.040 0.71 7.08 0.60 0.30 0.74 Straw w/ Net 23 2.40 265.7 361.0 351.4 9.6 2.06 0.036 0.52 7.08 8.84 0.88 1.98 Synthetic Mat 24 0.34 230.6 364.4 352.7 11.7 1.62 0.051 0.61 7.08 1.47 0.43 1.36 Straw w/ Net 25 0.38 221.2 354.3 352.7 1.6 3.33 0.007 0.81 7.08 2.18 0.65 0.29 Straw w/ Net 26 0.041 102.3 365.4 352.6 12.8 0.61 0.125 0.57 7.08 0.16 0.18 1.411 Straw w/ Net 27 0.081 106.0 353.6 352.6 1.0 1.71 0.009 0.76 7.08 0.43 0.34 0.201 Straw w/ Net 28 0.321 235.9 360.7 351.1 9.61 1.80 0.041 0.661 7.08 1.50 0.43 1.091 Straw w/ Net RIP RAP OULET PROTECTION ' '• 6 Structure= DATE: 10/01/2014 DESIGNED BY: Size= 42 in Q10 = DJB OJECT NAME: Northwest Community Church rp, PROJECT NO: 100.94 CHECKED BY OJECT LOCATION: Cary, NC 10.49 fps 130427 8.06.b.1: Storm Outlet Structure From Fig. 8.06.b.2: Structure= FES -10 Q10 /Qfull = 0.56 Size= 36 in V /Vfull = 1.02 Q10 = 26.81 cfs V = 7.0 fps Qfull = 48.02 cfs Vfull = 6.79 fps From Fig. 8.06.b.1: Zone = 6 From Fig. 8.06.b.2: D50 = 14 in DMAX = 21 in Riprap Class = 2 s Apron Thickness = 36 in 3 Apron Length = 30.0 ft Apron Width = 3 x Dia = 9.0 ft Length Storm Outlet Structure Structure= FES -20 Size= 42 in Q10 = 69.46 cfs Qfull = 100.94 cfs Vfull = 10.49 fps From Fig. 8.06.b.1: From Fig. 8.06.b.2: weMI S+ D50 DMAX Riprap Class Apron Thickness Apron Length Apron Width = 3 x Dia Q10 /Qfull = V /VfuII = V= 0.69 1.07 11.3 fps As 14 in 21 in 2 36 in 35.0 ft 11.0 ft • 1 =1 a a :,Lei I =M I Lei DATE: 10/01/2014 DESIGNED BY: DJB PROJECT NAME: Northwest Community Church PROJECT NO: CHECKED BY PROJECT LOCATION: Cary, NC 13427 Storm Outlet Structure Structure= FES -40 Q10 /Qfull = 0.76 Size= 24 in V /Vfull = 1.10 Q10 = 12.32 cfs V = 5.6 fps Qfull = 16.13 cfs Vfull = 5.13 fps From Fig. 8.06.b.1: Zone From Fig. 8.06.b.2: D50 Storm Outlet Structure Structure= FES -60 Size= 15 in Q 1 0 = 13.33 cfs Qfull = 48.73 cfs Vfull = 39.71 fps From Fig. 8.06.b.1: From Fig. 8.06.b.2: DMAX Riprap Class Apron Thickness Apron Length Apron Width = 3 x Dia Zone D50 D MAX Riprap Class Apron Thickness Apron Length Apron Width = 3 x Dia Q10 /Qfull = V /VfuII = V= E 8 in 12 in B 22 in 12.0 ft 6.0 ft 0.27 0.83 33.0 fps r 8 in 12 in B 22 in 7.5 ft 4.0 ft • r DATE: 10/01/2014 DESIGNED BY: DJB PROJECT thwest Community Church PROJECT NO: CHECKED BY PROJECT : Cary, NC 130427 Storm Outlet Structure Structure= FES -70 Q10 /Qful1 = 0.55 Size= 15 in V/Vfull = 1.02 Q10 = 4.32 cfs V = 6.6 fps Qfull = 7.90 cfs Vfull = 6.44 fps From Fig. 8.06.b.1: Zone = 2 From Fig. 8.06.b.2: D50 = 8 in DMAx = 12 in Riprap Class = B s Apron Thickness = 22 in 3 Apron Length = 7.5 ft Length Apron Width = 3 x Dia = 4.0 ft • r DATE: 10/01/2014 DESIGNED BY: DJB PROJECT thwest Community Church PROJECT NO: CHECKED BY PROJECT : Cary, NC 130427 Storm Outlet Structure Structure= TEMP FES Q10 /Qful1 = 0.73 Size= 18 in V/Vfull = 1.09 Q10 = 16.45 cfs V = 14.0 fps Qfull = 22.64 cfs Vfull = 12.81 fps From Fig. 8.06.b.1: Zone = 3 From Fig. 8.06.b.2: D50 = 10 in DMAx = 15 in Riprap Class = 1 s Apron Thickness = 24 in 3 Lim -0 Apron Length = 12.0 ft Length Apron Width = 3 x Dia = 5.0 ft Y V1111G COUNTY NORTH CAROLINA Environmental Services TEL 919 856 7400 FAx 919 743 4772 Water Quality Division 336 Fayetteville Street • Raleigh, INC 27602 www.wakegov.com 77, Environmental Services July 16, 2013 Steven Ball Registered Forester # 1723 Soil and Environmental Consultants, PA 11010 Raven Ridge Road Raleigh, NC 27614 WC -13 -003 TEL 919 856 7400 Fax 919 743 4772 Water Quality Division 336 Fayetteville Street • Raleigh, NC 27602 www.wakegov.com Wake County Project Name: Northwest Community Church Property Location/Directions: 10109 Morrisville Pkwy, PIN # 0724236305 Subject Stream: UT to Rocky Ford Branch Date of Determination: 7/10/13 Feature Not Subject Subject Start@ Stop@ Soil Survey USGS Topo A S03 B C D E Pond 1 Pond 2 Explanation: The feature(s) listed above has or have been located on the Soil Survey of Wake County, North Carolina or the most recent copy of the USGS Topographic map at a 1:24,000 scale. Each feature that is checked "Not Subject" has been determined not to be a stream or is not present on the property. Features that are checked "Subject" have been located on the property and possess characteristics that qualify it to be a stream. There maybe other streams located on your property that do not show up on the maps referenced above but, still may be considered jurisdictional according to the US Army Corps of Engineers and /or to the Division of Water Quality. Feature A starts at Flag S03 which is lust offsite from this parcel. This on -site determination shall expire five (S) years from the date of this letter. Landowners or affected parties that dispute a determination made by the DWQ or Delegated Local Authority may request a determination by the Director. An appeal request must be made within sixty (60) days of date of this letter or from the date the affected party (including downstream and /or adjacent owners) is notified of this Jordan Buffer Letter WC -13 -003 Page 2 of 2 letter. A request for a determination by the Director shall be referred to the Director in writing c% Ian McMillan, DWQ Wetlands /401 Unit, 1650 Mail Service Center, Raleigh, NC 27699 -1650. If you dispute the Director's determination you may file a petition for an administrative hearing. You must file the petition with the Office ofAdministrative Hearings within sixty (60) days of the receipt of this notice of decision. A petition is considered filed when it is received in the Office ofAdministrative Hearings during normal office hours. The Office of Administrative Hearings accepts filings Monday through Friday between the hours of 8 :00 am and 5: 00 pm, except for official state holidays. To request a hearing, send the original and one (1) copy of the petition to the Office ofAdministrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. The petition may also be faxed to the attention of the Office ofAdministrative Hearings at (919) 733 -3478, provided the original and one (1) copy of the document is received by the Office ofAdministrative Hearings within five (5) days following the date of the fax transmission. A copy of the petition must also be served to the Department of Natural Resources, c% Mary Penny Thompson, General Counsel, 1601 Mail Service Center, Raleigh, NC 27699 -1601. This determination is final and binding unless, as detailed above, you askfor a hearing or appeal within sixty (60) days. The owner /future owners should notify the Division of Water Quality (including any other Local, State, and Federal Agencies) of this decision concerning any future correspondences regarding the subject property (stated above). This project may require a Section 404/401 Permit for the proposed activity. Any inquiries should be directed to the Division of Water Quality (Central Office) at (919)- 807 -6301, and the US Army Corp of Engineers (Raleigh Regulatory Field Office) at (919) -554 -4884. If you have any questions regarding this determination, please contact me at (919) 856 -7541. Respectfully, Betsy Pearce, CFM, CPSWQ Environmental Engineer / Consultant cc: WC File Copy Attachment WITHERS & RAVENEL STORMWATER MANAGEMENT REPORT HOWARD /EMERSON TRACT - COMMERCIAL Cary, North Carolina Prepared For: NORTHWEST COMMUNITY CHURCH 7712 CARPENTER FIRE STATION RD CARY NC 27519 ATTN: MR. JOEL CARPENTER Prepared By: WITHERS & RAVENEL, INC 115 MacKenan Drive Cary, North Carolina 27511 Revised October 2014 W &R Project No. 02130427 "w1 frr � N CAR"', ,,• F S�jQ•.•r to. Z. Iq Jennifer C. Diaz, PE Clay Parrish, El HOWARD /EMERSON TRACT NORTHWEST COMMUNUNITY CHURCH - COMMERCIAL STORMWATER MANAGEMENT REPORT CARY, NORTH CAROLINA INTRODUCTION The proposed Howard /Emerson Tract development is located southwest of the intersection of Morrisville Parkway and White Oak Church Road in Cary, NC. The 20.07 acre development is proposed as a church with associated parking and infrastructure. It is less than 24% and is therefore considered low density. The site in its existing conditions is approximately 80% wooded with some open space and impervious area. The site is bound by White Oak Church Road to west, Morrisville Parkway to the north and the American Tobacco Trail to the east — all of which are higher than the site. The site drains towards the center and is collected via an unregulated stream feature which exits the site along the southern boundary. The site is comprised of HSG "D" soils. A soils map is provided in the Background Data portion of this report. Site outlined in blue. The impacts of the increased runoff from the development will be mitigated with a wet pond. The BMP will be oversized in order to accommodate future development. Although the proposed development is low density, the proposed BMP and storm drain network are designed to capture the proposed impervious area to the maximum extent practical in anticipation that future development would increase impervious area above 24% thereby making the site high density in the future. STORMWATER MANAGEMENT REQUIREMENTS The proposed development is with the Jordan Lake, Lower New Hope watershed. The site must therefore meet Town requirements relating to town wide ordinances and policies for stormwater NWCC - Commercial 1 W &R Project 02130427 Stormwater Management Plan Revised October 2014 HOWARD /EMERSON TRACT NORTHWEST COMMUNUNITY CHURCH - COMMERCIAL STORMWATER MANAGEMENT REPORT CARY, NORTH CAROLINA compliance. To meet these requirements the Nitrogen export rates from the site are to be reduced to 4.4 lbs /ac /yr; Phosphorus export rates to 0.78 lbs /ac /yr. This is accomplished through the use of a wet pond. Additionally, peak flows at the point of analysis shall be reduced to predevelopment levels for the 1 -year storm and larger storms must also be controlled to within the anticipated flows from R -40 zoning or 1o% of predevelopment flows, whichever is less. METHODOLOGY The stormwater study was conducted using the natural drainage features as depicted by LIDAR topography and existing field surveys. Proposed drainage areas were based on field survey data and proposed development within the drainage areas. The scope of work included the following analyses: Hydrology ❑ Simulation of the 1 -year, 2 -year, 5 -year, 10 -year, and loo -year rainfall events for the Cary, NC area ❑ Formulation of the 1 -year, 2 -year, 5 -year, 10 -year, and loo -year flood hydrographs for the pre- and post- development drainage areas Hydraulic ❑ Routing the 1 -year, 2 -year, 5 -year, so -year, predevelopment runoff from the site. ❑ Routing the 1 -year, 2 -year, 5 -year, 10 -year, and development runoff through the stormwater BMP. ❑ Analyzing results at the analysis point and soo -year flood hydrographs for soo -year flood hydrographs for post- The results of the hydrology calculations are used in the hydraulic analyses. The hydraulic design requires the development of stage- storage and stage- discharge functions for the BMP. The rainfall /runoff hydrographs, stage- storage, and stage- discharge functions have been compiled to create a computer routing simulation model using Bentley Systems PondPack v1o.o software. This PondPack model was then used to assess the peak water surface elevations in the BMP forthe design rainfall events. The PondPack modeling results are provided as appendices to this report. HYDROLOGY The SCS Method, in conjunction with NOAA Atlas 14 rainfall data for Raleigh- Durham International Airport, was used to develop runoff hydrographs for the storm events. This method requires three basic parameters: a curve number (CN), time of concentration (tc), and drainage area. Curve numbers were based on soil type and land use. Soil types were delineated from the Soil Survey of Wake County, North Carolina (November 1970). The curve numbers used in this study are listed in the PondPack section of this report. Time of concentration for pre- and post- development drainage areas were developed using the TR -55 method. A minimum time of concentration of 5 minutes was used for the proposed piped drainage systems. NWCC - Commercial 2 W &R Project 02130427 Stormwater Management Plan Revised October 2014 HOWARD /EMERSON TRACT NORTHWEST COMMUNUNITY CHURCH - COMMERCIAL STORMWATER MANAGEMENT REPORT CARY, NORTH CAROLINA HYDRAULICS Computer simulated reservoir routing of the 1 -year, 2 -year, 5 -year, io -year, and loo -year design storms utilized stage- storage and stage- discharge functions. Stage- storage functions were derived from the proposed geometry of the BMP. A non - linear regression relation for surface area versus elevation was derived for each BMP. This relation estimates the incremental volume of the basin to the stage or elevation of the basin. Stage- discharge functions were developed to size the proposed outlet structures for the BMP. NITROGEN EXPORT The Nitrogen and Phosphorus export rates for the development were calculated using Jordan/ Falls Lake Stormwater Nutrient Load Accounting Tool. All onsite drainage areas, including roadway and driveway improvements, were used in the nutrient export analysis. The worksheet used to calculate the nutrient export loading rate can be found in the appendices. CONCLUSIONS Quality Based upon the routing study, the proposed stormwater management plan has sufficient measures to provide the necessary removal of nutrients as required by Town policy. The proposed stormwater wet pond has been designed to store and treat the water quality volume (runoff associated with the first 1" of rainfall, WQv) generated by the contributing drainage area, and draw down that volume in at least z days, but no slower than 5 days. Because the runoff resulting from the first i" of rainfall is being discharged perthe NCDENR standards for a wet pond, the appropriate reduction credits were taken for the area draining through the BMP. The BMP treatment resulted in bringingthe total site's Nitrogen and Phosphorus export down to below target levels. Quantity The peak flows from the site have been attenuated for predevelopment levels. Furthermore, the proposed BMP has sufficient storage to safely pass the loo -year storm event without overtopping. Future Expansion The proposed SWMP and BMP have been designed with possible future development in mind. The BMP has been sized to accommodate an additional 2.5 acres of impervious area for both water quality and quantity control. This analysis of future impervious assumes that all of it drains to the BMP without additional bypass. Although this SWMP and BMP have accounted for future impervious area in this study, any expansion to the site will still be subject to Town of Cary standards at the time of site plan submittal. NWCC - Commercial 3 W &R Project 02130427 Stormwater Management Plan Revised October 2014 HOWARD /EMERSON TRACT NORTHWEST COMMUNUNITY CHURCH - COMMERCIAL STORMWATER MANAGEMENT REPORT CARY, NORTH CAROLINA DESIGN SUMMARY BMP #1 - WET POND DRAINAGE AREA =16.10 ACRES PERCENT IMPERVIOUS AREA = 44% (INCLUDES OFFSITE AND FUTURE DEVELOPMENT) • 2.5" DRAWDOWN ORIFICE AT EL 351.0 • 2 -3' WIDE PEAK CONTROL WEIRS AT EL = 352.5 5'x5' RISER, CREST EL = 353.5 36" 0 -RING RCP OUTLET EL = 344.00 Top OF DAM EL = 356.00 BMP #1- Wet Pond Routing Summary Storm Event Peak Water Surface Elevation Freeboard Qpeak Outflow (total) (ft) (ft) (cfs) 1 -Year 353.30 2.70 13.17 2 -Year 353.70 2.30 27.88 5 -Year 354.03 1.97 50.28 10 -Year 354.20 1.8o 64.3 loo -Year 354.51 1.49 90.54 PEAK ATTENUATION SUMMARY NWCC - Commercial 4 W &R Project 02130427 Stormwater Management Plan Revised October 2014 Pre Development Post Development Net Change Net Change Peak Flow Peak Flow w /BMP (cfs) NO Storm Event (cfs) (cfs) 1 -Year 35.91 17.45 -18.46 -51% 2 -Year 52.36 36.24 -16.12 -31% 5 -Year 71.30 64.62 -6.68 -9% 10 -Year 86.36 84.33 -2.03 -2% loo -Year 125.04 119.24 -5.8o -5% NWCC - Commercial 4 W &R Project 02130427 Stormwater Management Plan Revised October 2014 HOWARD /EMERSON TRACT NORTHWEST COMMUNUNITY CHURCH - COMMERCIAL STORMWATER MANAGEMENT REPORT CARY, NORTH CAROLINA BACKGROUND INFORMATION NWCC - Commercial W &R Project 02130427 Stormwater Management Plan Revised October 2014 35° 47 41" N 35° 47 23" N 3 Hydrologic Soil Group —Wake County, North Carolina 3 (NWCC - Commercial) N m m 687430 697450 687550 6976.10 687670 687730 68877% 687430 667490 687550 687610 687670 3 Map Scale: 1:2,600 if printed on A portrait (8.5" x 11 ") sheet. N — ,Meters n 0 35 70 140 210 0 100 200 400 600 Map projection: Web Mercator Comer coordinates: WGS84 Edge tics: UTM Zone 17N WGS84 U Natural Resources Web Soil Survey Conservation Service National Cooperative Soil Survey 687730 687790 3 m 35" 47 41" N M m R O M M O R O N M O M mR N M N M O M n N M O n N M 7/8/2014 Page 1 of 3 35° 47 23'N M 0 f0 U L 0 0 Z C •N 7 2 O p) U E Y E O O U IU 0 ' � S Z 0 U) U O O T Z O F- 0 O LL Z Ca C 0 Z W 0 W J a d C C m N o N o N p� > N o U N .O f/7 O .' U f0 Q L O N p O m > ` N N U �� f0 a f0 E N N 3c o o a U O C V V a Cp Q) (0 0 L N O N ❑ U U N N 0 N 7 C O U fOUA N U E U) N N cD E � R d N 13 LL CL 7 *y N N � Y OI• C U 7 cm o� U N N O y� O 3 � CD .N U f0 U In N L N U O IO E N L O U N f0 N TM C Q N > 0 U M O O C '^ E m �p N Cn y N U) Z U U N Z L a) Z U N O a� U E N L a) cn E 0 1 Lil m t N o t ;" c ' (C IC Q r f0 L N 1] Q t N U) Z CD a. ❑ ❑ a¢ C N N IC N C Z 0 U l91 r C O T U 0 N N N O r fLA O ' N C 7 0 N l0 C• V f0 N w E C r 7 r O N L f0 Q E �" N L L C O 0 O N � nL _O 7 N t •O l0 O N O U p N Q L N� O >, Cj, C C N O N f0 U L N N V) 0 0 p_ p — Z O _O U L Y E N L- N E M l0 J U) N Q C C N > E E cD 0 IC > L Z �' L `� Q U N N l0 m 0 N 0 f0 M E c C w T� �L d N� O)N f0 E O.LM TC O L� C N Q O T N U Co M '� L N M z❑ 0 0- M> p o m 'o o m ) U L 3 c m m Y'i Q m t r- Q- U) N W U Np �" E V) N 0 E C 7 C 7 p N j O l9 o M C 7 '` E L 0 C U w ,O U 0 '� 0 cn O` y 7 T � N L� 2+ .Q rn f0 O N N N IO l0 > L p N C 7 Q .� Q N U) N — Z E� — N O N f0 N E l�0 E O C .N N '0 W E A N N N d E p 0 0 (/) U M O N L_ Q Q U L y H O U) U) V) O ❑ N O E H U .- O a� La La > N o U T L 0 a m m m 0 r a f0 E m o o a �° a ❑ U U N Q N 9 r 'w ❑ Z in O= N 5 V) Z) U < � R d N 13 LL CL 7 *y C U 7 cm 3 � m N O C O C O N O rn O N O a� N a o M 0 a. ❑ 0 0 0 C ❑ ❑ ❑ o a. ❑ ❑ a¢ m< m'o U L) in Z c¢ a m m L) ❑ Z 0¢ a m m n 0[1 F1 11 11� t/ 9 H a� •0 V) o Vl i l a .o fn a UY Hydrologic Soil Group —Wake County, North Carolina Hydrologic Soil Group NWCC - Commercial Hydrologic Soil Group— Summary by Map Unit— Wake County, North Carolina (NC183) Map unit symbol Map unit name Rating Acres in AOI I Percent of AOI CrB Creedmoor sandy loam, D 2 to 6 percent slopes CrB2 Creedmoor sandy loam, D 2 to 6 percent slopes, moderately eroded CrC Creedmoor sandy loam, D 6 to 10 percent slopes CrC2 Creedmoor sandy loam, D 6 to 10 percent slopes, moderately eroded CrE Creedmoor sandy loam, D 10 to 20 percent slopes WyA Worsham sandy loam, 0 D to 3 percent slopes Totals for Area of Interest Rating Options Aggregation Method: Dominant Condition Component Percent Cutoff: None Specified Tie -break Rule: Higher 0.2 7.7 0.2 9.7 Iff 1.1 20.1 1.1% 38.4% 1.1% 48.3% 5.5% 5.7% 100.0% USDA Natural Resources Web Soil Survey 7/8/2014 Conservation Service National Cooperative Soil Survey Page 3 of 3 HOWARD /EMERSON TRACT NORTHWEST COMMUNUNITY CHURCH - COMMERCIAL STORMWATER MANAGEMENT REPORT CARY, NORTH CAROLINA BMP SIZING CALCULATIONS NWCC - Commercial W &R Project 02130427 Stormwater Management Plan Revised October 2014 Project Name: Howard /Eemerson Tract - Commercial City /State: Cary, NC BMP #1 Project #: 2130427 Date: 1- Oct -14 Table 10.3 Surface Area to Drainage Area Ratio for Permanent Pool Sizing for 90% Pollutant Removal Efficiency in the Piedmont % Impervious Permanent Pool Depth 3.0 4.0 5.0 6.0 (feet) 7.0 8.0 9.0 10 0.9 0.8 0.6 0.5 0.5 0.4 0.4 20 1.5 1.1 1.0 0.9 0.8 0.7 0.7 30 1.9 1.7 1.4 1.3 1.0 0.9 0.9 40 2.5 2.0 1.8 1.6 1.5 1.2 1.1 50 3.0 2.5 2.0 1.9 1.7 1.5 1.5 60 3.5 2.8 2.5 2.2 1.9 1.8 1.7 70 4.0 3.3 2.8 2.5 2.2 2.0 1.9 80 4.5 3.8 3.3 2.8 2.6 2.1 2.0 90 5.0 4.0 3.5 3.0 2.8 2.5 2.4 Source: NCDENP/DWQ Stormwater Best Management Practices, pg. 10 -15, July 2007 rev. 6/16/09 STORMWATER BMP #1- STORMWATER WET POND (25% TN Removal) Land Use Area (ac) % IA Imp. Area (ac) Impervious 3.44 100 3.44 Open Space 8.36 0 0.00 Future Impervious 2.50 100 2.50 OFFSITE impervious 1 1.80 1 60 1.08 Totals 1 16.10 1 1 7.02 Total % Impervious Surface Area = 43.6 % Surface Area of Permanent Pool: Average depth = 5.00 ft SA/DA ratio = 1.87 From Table 10.3 Minimum pond surface area (SA) = (DA * SA/DA ratio) /100 SA = 0.301 acres 13133 sq. ft. Normal pool elevation = 351.0 feet Surface area provided = 0.377 acres 16428 sq. ft. 1 -Inch Runoff Volume Calculation Using the runoff volume calculations in the "Simple Method" as described by Schueler (1987) Rv = 0.05 + 0.009(1) where, Rv = Runoff coefficient, in. /in. I = Percent impervious Rv = 0.44 in. /in. Total runoff volume from 1 -inch precipitation: Runoff volume, S = (Design rainfall) (Rv) (Drainage Area) S = 0.594 acre -ft 25871 cu. ft. Water quality pool elevation= 352.38 feet Overflow elevation= 352.50 feet Storage volume provided = 0.653 acre -ft 28445 cu.ft. K: \13 \13- 0420 \130427 - Northwest Community Church \H -H \Commercial \BMP #1 BMP #1 - Pond Design Project Name: Howard /Eemerson Tract - Commercial Project #: 2130427 City /State: Cary, NC BMP #1 Date: 1- Oct -14 STORMWATER BMP #1- STORMWATER WET POND (25% TN Removal) AVERAGE DEPTH Per NCDENR "Stormwater Best Management Practices ", the average depth of a wet pond is to be calculated by one of these two options: K: \13 \13- 0420 \130427- Northwest Community Church \H -H \Commercial \BMP #1 BMP #1 - Basin Sizing Incremental Accumulated Below Normal Contour Contour Contour Pool Contours Area Volume Volume (feet) (SF) (CF) (CF) 343.00 5809 Abot_ pond 344.00 6613 6207 6207 — Sediment Storage Volume 346.00 8366 14945 21151 350.00 12457 41375 62527 Abot shelf 350.50 13737 6546 69073 Aperm pool 351.00 16428 7531 76604 —Total Pond Volume PPS = Total Volume - Sediment Storage Volume = 70,397 cf OPTION 1: Average Depth = Permanent Pool Volume / Surface Area PPV = 70,397 cf SA = 16,428 sf day = 4.29 ft OPTION 2: Use the following equation: da„ = 0.25 x (1 + Abot_ shelf )+ (Abot_ shelf + Abot_oond) x Depth Aperm_ pool 2 Abot shelf day, = (0.25 x (1 + 13737 )) + ( 13737+ 5473 ) x 6.5 16428 2 13737 day = 5.27 ft Use Average Depth = 5.00 ft OPTION 2 K: \13 \13- 0420 \130427- Northwest Community Church \H -H \Commercial \BMP #1 BMP #1 - Basin Sizing Project Name: Howard /Eemerson Tract - Commercial Project #: 2130427 City /State: Cary, NC BMP #1 Date: 1- Oct -14 STORMWATER BMP #1- STORMWATER WET POND (25% TN Removal) Orifice Calculator Q = Cd *A *(2gh)'(1/2) 1" WATER QUALITY STORM VOLUME Variables Constants WQ Volume: 0.594 Acre -ft 25871 cf g = 32.2 ft/s2 Head / Driving Head: 1.38 ft 0.46 ft Cd= 0.6 Draw down time: 65 hrs 234099 s Orifice Area = 0.034 sq. ft Orifice Diameter = 2.491 in USE 2.5 INCH DIAMETER ORIFICE 4.873 sq. in K: \13 \13- 0420 \130427- Northwest Community Church \H -H \Commercial \BMP #1 BMP #1- Orifice Calculator HOWARD /EMERSON TRACT NORTHWEST COMMUNUNITY CHURCH - COMMERCIAL STORMWATER MANAGEMENT REPORT CARY, NORTH CAROLINA NITROGEN LOADING CALCULATIONS NWCC - Commercial W &R Project 02130427 Stormwater Management Plan Revised October 2014 Jordan Lake Developer Nutrient Reporting Form Please complete and submit the following information to the local government permitting your development project to characterize it and assess the need to purchase nutrient offsets. Contact and rule implementation information can be found online at http: / /Dortal.ncdenr.org/ web /wq /ps /nps /nutrientoffsetintro. PROJECT INFORMATION (for Jordan Lake) Applicant Name: Northwest Community Church Project Name: Howard /Eemerson Tract - Commercial Project Address (if available): Street: City /Town: County: Morrisville Parkway and White Oak Church Road, Cary, Wake Date: (mo/d/yr) Project Lat: (decimal degrees) Long: (decimal degrees) 7/10/2014 Location : 35.791340° 1 - 78.925725° Is this Redevelopment? Yes Development Type (Please check all that apply) X No Impervious Cover ( %): 1 % HIndustrial Commercial Mixed -Use Single Fam. Residential (Pre- Construction) Duplex Residential HMulti-Fam. Residential Impervious Cover ( %): 19% Institutional (Post- Construction) I H JORDAN WATERSHED INFORMATION Small Watershed ID (6 digits): (See next page or online map.) New Development Load Requirements (See individual rules 60150 for a full description of nutrient requirements.) Jordan Subwatershed (Please check one) Loading Rate Targets Offsite Thresholds Nitrogen (N) & Phosphorus (P) Z.Z N iDiaciyr 0.82 P Ib /ac /yr 4.4 N Ib /ac /yr 0.78 P Ib /ac /yr he offsite thresholds — see above) 6 N Ibs /ac Residential; 10 N Ibs /ac Commercial (must meet all onsite treatment requirements) (D) Upper New Hope EX Lower New Hope NUTRIENT OFFSET REQUEST(Must meet t Nitrogen Loading / Offset Needs (A) (B) (C) Untreated Treated Loading Rate Loading Rate Loading Rate Target (Ibs /ac /yr) (Ibs /ac /yr) (Ibs /ac /yr) 3.52 2.41 4.40 Phosphorus Loading / Offset Needs Z.Z N iDiaciyr 0.82 P Ib /ac /yr 4.4 N Ib /ac /yr 0.78 P Ib /ac /yr he offsite thresholds — see above) 6 N Ibs /ac Residential; 10 N Ibs /ac Commercial (must meet all onsite treatment requirements) (D) (E) (F) (G) Reduction Need Project Offset Delivery (Ibs /ac /yr) Size (ac) Duration (yrs) Factor ( %) B -C Control of Peak Stormwater Flow (1 year 24 hour design storm) 0.00 20.07 30 88% (A) Untreated Loading Rate (Ibs /ac /yr) (B) Treated Loading Rate (Ibs /ac /yr) (C) Loading Rate Target (Ibs /ac /yr) (D) Reduction Need (Ibs /ac /yr) B - C (E) Project Size (ac) (F) Offs Duration 0.83 0.49 0.78 0.00 20.07 30 Control of Peak Stormwater Flow (1 year 24 hour design storm) Calculated Predevelopment Peak Flow 35.91 Calculated Post Development Peak Flow 17.45 (H) State Buy Down Amount (Ibs) D`E'F`G 0 (G) (H) et Delivery State Buy Down (yrs) Factor ( %) Amount (Ibs) D "E'F`G 91% 0 Flow Control Method Wet Detention Pond Authorizing Local Government Name: Town of Cary Staff Name: I Matt Flynn Staff Email: matt.flynn @townofcary.org Phone: 919.469.4347 Jordan Nutrient Load Reporting Form. September 12, 2012 Physiographic /Geologic Region: Piedmont Soil Hydrologic Group D Precipitation location: Raleigh COLUMN 1 -- NON- RESIDENTIAL LAND USES 874,191 TN EMC I TP EMC (rng /L) (mg /L) COMMERCIAL Howard /Eemerson Tract - Commercial Post - Development (ftz) Pre- Development (ftz) Parking lot 1.44 0.16 -ac lots 111,302 Roof 1.08 0.15 18,594 Open /Landscaped 2.24 0.44 1 -ac lots INDUSTRIAL Parking lot 1.44 0.39 2-ac lots Roof 1.08 0.15 Multi- family Open /Landscaped 2.24 0.44 Townhomes TRANSPORTATION High Density (interstate, main) 3.67 0.43 Custom Lot Size Low Density (secondary, feeder) 1.4 0.52 PART B Roadway Rural 1.14 0.47 12,900 1.0 1.44 Parking lot Sidewalk 1.4 1.16 32,000 Sidewalk /Patio PERVIOUS Lawn Managed pervious 3.06 0.59 3.06 416,523 1.47 Unmanaged (pasture) 3.61 1.56 244,917 Open water* Forest 1.47 0.25 616,374 295,772 JURISDICTIONAL LANDS* Natural wetland Riparian buffer Open water LAND TAKEN UP BY BMPs 1.08 0.15 *Jurisdictional land uses are not included in nutrient /flow calculations. Total Development Area (ft 2): 874,191 Development Name: Howard /Eemerson Tract - Commercial Model Prepared By: JCD COLUMN 2 -- RESIDENTIAL LAND USES Custom Age TN EMC TP EMC Pre- Post - Lot Size Development Development (ac) (yrs) (mg /L) (mg /L) (ftz) (ftz) PART A %-ac lots -ac lots Y. -ac lots 1 -ac lots 2-ac lots Multi- family Townhomes Custom Lot Size PART B Roadway 1.4 0.52 0.39 0.39 0.15 1.16 0.44 0.59 0.25 -- 0.15 Driveway 1.0 1.44 Parking lot 1.44 Roof 1.08 Sidewalk /Patio 1.4 Lawn 2.24 Managed pervious 3.06 Forest 1.47 Natural wetland* Riparian buffer* Open water* LAND TAKEN UP BY BMPs -- 1.0.0 8 LAND USE AREA CHECK Total Development Area Entered (ft'): 874,191 Total Pre - Development Calculated Area (ft): 874,191 Total Post - Development Calculated Area (ftz): 874,191 Type of BMP: If BMP is undersized, indicate the BMP's size relative to the design size required to capture the designated water quality depth (i.e. 0.75 = BMP is 75% of required design size): *For water harvesting BMP, enter percent volume reduction in decimal form. Catchment 1: Catchment 2: Catchment 3: Catchment 4: Catchment 5: Catchment 6: Drainage Area Land Use MMERCIAL Parking lot Roof Open /Landscaped )USTRIAL Parking lot Roof Open /Landscaped ANSPORTATION High Density (interstate, main) Low Density (secondary, feeder) Rural Sidewalk SC. PERVIOUS 2 -ac lots (New) 2 -ac lots (Built after 1995) 2 -ac lots (Built before 1995) 1 -ac lots (New) 1 -ac lots (Built after 1995) 1 -ac lots (Built before 1995) -ac lots (New) % -ac lots (Built after 1995) % -ac lots (Built before 1995) Y -ac lots (New) Y -ac lots (Built after 1995) X -ac lots (Built before 1995) % -ac lots (New) A -ac lots (Built after 1995) %-ac lots (Built before 1995) Townhomes (New) Townhomes (Built after 1995) Townhomes (Built before 1995) Multi- family (New) Multi- family (Built after 1995) Multi- family (Built before 1995) Custom Lot Size (New) Custom Lot Size (Built after 1995) Custom Lot Size (Built before 1995) Sidewalk Lawn Managed pervious Forest NO TAKEN UP BY BMP TOTAL AREA TREATED BY BMP (ftz): TOTAL AREA TREATED BY SERIES (ft): ......................."" BMP #1 Wet Detention Pond CATCHMENT 1 ----------------------------- BMP #2 BMP #3 no no no no no no no no no no no no no no no Area treated Area treated Area Treated by BMP #3 that is not by BMP by BMP #2 that is not treated by BMPs #1 treated by BMP #1 (ft z) or #2 1ft' 1 (ft) 106,300 16,042 16,042 325,907 158,617 622,908 0 0 622,908 3. Development Summary Development: Howard /Eemerson Tract - Commercial Prepared By: JCD Date: October 2, 2014 WATERSHED SUMMARY Ver2.0 REGION: Piedmont TOTAL DEVELOPMENT AREA (ft ): 874,191 Percent Impervious ( %) 17% 17% 0% Pre - Development Conditions Post - Development Conditions Post - Development w/ BMPS Percent Impervious 1,5% 18.5% 1815% ( %) Total Nitrogen Loading (lb /ac /yr) 189% 98% Annual Runoff Volume Total Phosphorus EMC (mg/L) -18% -59% (c.f.) 209,338 716,782 657,865 Total Nitrogen EMC 0.26 1.08 0.15 (mg/L) 1.87 1.58 1.18 Total Nitrogen Loading 1.20 0.15 Permeable (lb /ac/yr) 1.22 3.52 2.41 0% 1.44 0.39 Total Phosphorus EMC (mg /L) 0.59 0.48 0.24 user defined 1.08 0.15 Total Phosphorus Loading (lb /ac /yr) 0.38 0.83 0.49 Percent Difference Between: Negative percent difference values indicate a decrease in runoff volume, pollutant concentration or pollutant loading. Positive values indicate an increase. BMP SUMMARY Ver2.0 BMP VOLUME REDUCTIONS /EFFLUENT CONCENTRATIONS Pre -Dev. & Post -Dev. without BMPs Pre - Development & Post - Development with BMPs Post -Dev without BMPs & Post -Dev with BMPs Percent Impervious ( %) 17% 17% 0% Annual Runoff Volume (c.f.) 242% 214% -8% Total Nitrogen EMC (mg/L) -16% -37% -25% Total Nitrogen Loading (lb /ac /yr) 189% 98% -32% Total Phosphorus EMC (mg/L) -18% -59% -50% Total Phosphorus Loading (lb /ac /yr) 1 117% 1 29% 1 -41% Negative percent difference values indicate a decrease in runoff volume, pollutant concentration or pollutant loading. Positive values indicate an increase. BMP SUMMARY Ver2.0 BMP VOLUME REDUCTIONS /EFFLUENT CONCENTRATIONS `if treating commercial parking lot, TP effluent concentration = 0.16 mg/L Return to Instructions [ Return to Watershed Characteristics I Return to BMP Characteristics l Print Summary I CATCHMENT 1 Volume Reduction TN Effluent Concen. TP Effluent Concen. CATCHMENT 4 (%) (mg/L) (mg/L) Bioretention with BMP1 BMP2 BMP3 MIS 50% 0.95 0.12 Bioretention without BMP3 BMP1 BMP2 MIS 35% 1.00 0.12 Dry Detention Pond 0% 1.20 0.20 Grassed Swale 0% 1.21 0.26 1.08 0.15 Green Roof 50% Level Spdr, Filter 40% Strip 1.20 0.15 Permeable Pavement* 0% 1.44 0.39 Sand Filter 5% 0.92 0.14 Water Harvesting user defined 1.08 0.15 Wet Detention Pond 10% 1.01 0.11 Wetland 20% 1.08 0.12 `if treating commercial parking lot, TP effluent concentration = 0.16 mg/L Return to Instructions [ Return to Watershed Characteristics I Return to BMP Characteristics l Print Summary I CATCHMENT 1 CATCHMENT 2 CATCHMENT 3 CATCHMENT 4 CATCHMENTS CATCHMENT 6 BMP1 BMP2 BMP3 BMP1 BMP2 BMP3 BMP1 BMP2 BMP3 BMP1 BMP2 BMP3 BMP1 BMP2 BMP3 BMP1 BMP2 BMP3 39% - -- -- - -- Catchment Outflow Phosphorus EMC (mg/L) 0.134 Wet Detention Pond Catchment Outflow Total Phosphorus (lb /ac /yr) 0.311 - - -- Total Area Treated - Percent Reduction in Phosphorus Load ( %) 61% - -- -- - -- Total Inflow Volume 589,161 - - -- - -- -- - - - -- - -- - - - - - (c.f.) Percent Volume Reduced 10% Inflow Nitrogen EMC (mg/L) 1.57 Total Inflow Nitrogen (lb /ac /yr) 4.04 - - -- - -- Inflow Phosphorus EMC (mg/L) 0.306 -- - Total Inflow Phosphorus (lb /ac /yr) 0.79 BMP Outflow Nitrogen (Ibs /ac /yr) 2.48 - - -- - - - -- - - -- - -- - - - - - BMP Outflow Phosphorus (Ibs /ac /yr) 0.31 - - -- - - - - - - -- - -- - - - -- - Catchment Outflow Nitrogen EMC (mg/L) 1.07 - - -- - - Catchment Outflow 2.48 - - - - Total Nitrogen (lb /ac /yr) Percent Reduction in Nitrogen Load ( %) 39% - -- -- - -- Catchment Outflow Phosphorus EMC (mg/L) 0.134 _ Catchment Outflow Total Phosphorus (lb /ac /yr) 0.311 - - -- - - Percent Reduction in Phosphorus Load ( %) 61% - -- -- - -- HOWARD /EMERSON TRACT NORTHWEST COMMUNUNITY CHURCH - COMMERCIAL STORMWATER MANAGEMENT REPORT CARY, NORTH CAROLINA PONDPACK ROUTING CALCULATIONS NWCC - Commercial W &R Project 02130427 Stormwater Management Plan Revised October 2014 pre R Q Q 5' O to bmp Q Q x N O A w bmp PRE �©v 76 bypass Q Q W O A& o Job File: K: \13 \13- 0420 \130427- Northwest Community Church \H -H \Commercial \NWCC- COMM.PPW Rain Dir: K: \13 \13- 0420 \130427- Northwest Community Church \H -H \Commercial\ JOB TITLE Project Date: 7/9/2014 Project Engineer: jdiaz Project Title: 2130427 Project Comments: Revised 10/1/14 SIN: Bentley Systems, Inc. Bentley PondPack (10.00.027.00) 4:59 PM 10/1/2014 Table of Contents Table of Contents i * * * * * * * * * * * * * * * * * * * * ** MASTER SUMMARY * * * * * * * * * * * * * * * * * * * * ** Watershed....... Master Network Summary ............. 1.01 * * * * * * * * * * * * * * * * ** DESIGN STORMS SUMMARY * * * * * * * * * * * * * * * * * ** RDU 24 Hour Desi Design Storms ...................... 2.01 * * * * * * * * * * * * * * * * * * * * ** TC CALCULATIONS * * * * * * * * * * * * * * * * * * * ** BYPASS.......... Tc Calcs ........................... 3.01 PRE ............. Tc Calcs ........................... 3.03 TO BMP.......... Tc Calcs ........................... 3.05 * * * * * * * * * * * * * * * * * * * * ** CN CALCULATIONS * * * * * * * * * * * * * * * * * * * ** BYPASS.......... Runoff CN -Area ..................... 4.01 PRE ............. Runoff CN -Area ..................... 4.02 TO BMP.......... Runoff CN -Area ..................... 4.03 * * * * * * * * * * * * * * * * * * * * * ** POND VOLUMES * * * * * * * * * * * * * * * * * * * * * ** BMP ............. Vol: Elev -Area ..................... 5.01 SIN: Bentley PondPack (10.00.027.00) 4:59 PM Bentley Systems, Inc. 10/1/2014 Table of Contents Table of Contents (continued) ii * * * * * * * * * * * * * * * * * * ** OUTLET STRUCTURES * * * * * * * * * * * * * * * * * * * ** Outlet 1........ Outlet Input Data .................. 6.01 Composite Rating Curve ............. 6.04 SIN: Bentley Systems, Inc. Bentley PondPack (10.00.027.00) 4:59 PM 10/1/2014 Type.... Master Network Summary Page 1.01 Name.... Watershed File.... K: \13 \13- 0420 \130427- Northwest Community Church \H -H \Commercial \NWCC- comm.ppw MASTER DESIGN STORM SUMMARY Network Storm Collection: RDU 24 Hour Desi Total Depth Return Event in 1 2.8300 2 3.4400 5 4.3000 10 4.9800 100 7.3700 Rainfall Type --------------- - Time -Depth Curve Time - Depth Curve Time -Depth Curve Time -Depth Curve Time -Depth Curve RNF ID RDU NOAA lyr RDU NOAA 2yr RDU NOAA 5yr RDU NOAA 10yr RDU NOAA 100yr MASTER NETWORK SUMMARY SCS Unit Hydrograph Method ( *Node= Outfall; +Node = Diversion;) (Trun= HYG Truncation: Blank =None; L =Left; R =Rt; LR= Left &Rt) SIN: Bentley PondPack (10.00.027.00) 4:59 PM Bentley Systems, Inc. 10/1/2014 Max Return HYG Vol Qpeak Qpeak Max WSEL Pond Storage Node ID Type Event ac -ft Trun hrs cfs ft ac -ft ----------- BMP - - - - -- IN - - -- POND - - - - -- 1 ---- - - - - -- 2.238 -- --- - - - - -- 12.1000 -- - - - - -- 48.71 -- - - - - -- ------ - - - - -- BMP IN POND 2 2.971 12.1000 63.51 BMP IN POND 5 4.037 12.1000 78.65 BMP IN POND 10 4.898 12.1000 90.47 BMP IN POND 100 7.988 12.1000 118.20 BMP OUT POND 1 2.216 R 12.3000 13.17 353.30 1.054 BMP OUT POND 2 2.948 R 12.2500 27.88 353.70 1.265 BMP OUT POND 5 4.012 R 12.2000 50.28 354.03 1.443 BMP OUT POND 10 4.872 R 12.1500 64.39 354.20 1.538 BMP OUT POND 100 7.961 R 12.1500 90.54 354.51 1.715 BYPASS AREA 1 .512 12.1000 10.98 BYPASS AREA 2 .731 12.1000 15.79 BYPASS AREA 5 1.063 12.1000 21.27 BYPASS AREA 10 1.339 12.1000 25.62 BYPASS AREA 100 2.368 12.1000 36.67 SIN: Bentley PondPack (10.00.027.00) 4:59 PM Bentley Systems, Inc. 10/1/2014 Type.... Master Network Summary Page 1.02 Name.... Watershed File.... K: \13 \13- 0420 \130427- Northwest Community Church \H -H \Commercial \NWCC- comm.ppw MASTER NETWORK SUMMARY SCS Unit Hydrograph Method ( *Node = Outfall; +Node = Diversion;) (Trun= HYG Truncation: Blank =None; L =Left; R =Rt; LR= Left &Rt) SIN: Bentley PondPack (10.00.027.00) 4:59 PM Bentley Systems, Inc. 10/1/2014 Max Return HYG Vol Qpeak Qpeak Max WSEL Pond Storage Node ID ----------- - - Type - - -- - - -- Event - - - - -- ac -ft ---- - - - - -- Trun -- hrs --- - - - - -- cfs ft ac -ft -- - - - - -- -- - - - - -- ------ - - - - -- *POST JCT 1 2.728 R 12.2000 17.45 *POST JCT 2 3.678 R 12.2000 36.24 *POST JCT 5 5.075 R 12.1500 64.62 *POST JCT 10 6.211 R 12.1500 84.33 *POST JCT 100 10.328 R 12.1500 119.24 PRE AREA 1 1.688 12.1000 35.91 PRE AREA 2 2.428 12.1000 52.36 PRE AREA 5 3.561 12.1000 71.30 PRE AREA 10 4.507 12.1000 86.36 PRE AREA 100 8.048 12.1000 125.04 *PRE JCT 1 1.688 12.1000 35.91 *PRE JCT 2 2.428 12.1000 52.36 *PRE JCT 5 3.561 12.1000 71.30 *PRE JCT 10 4.507 12.1000 86.36 *PRE JCT 100 8.048 12.1000 125.04 TO BMP AREA 1 2.238 12.1000 48.71 TO BMP AREA 2 2.971 12.1000 63.51 TO BMP AREA 5 4.037 12.1000 78.65 TO BMP AREA 10 4.898 12.1000 90.47 TO BMP AREA 100 7.988 12.1000 118.20 SIN: Bentley PondPack (10.00.027.00) 4:59 PM Bentley Systems, Inc. 10/1/2014 Type.... Design Storms Name.... RDU 24 Hour Desi Page 2.01 File.... K: \13 \13- 0420 \130427- Northwest Community Church \H -H \Commercial \NWCC - comm.ppw Title... Project Date: 7/9/2014 Project Engineer: jdiaz Project Title: 2130427 Project Comments: Revised 10/1/14 DESIGN STORMS SUMMARY Design Storm File,ID = RDU 24 Hour Desi Storm Tag Name = 1 ---------------------------------------------------------------- - - - - -- Data Type, File, ID = Time -Depth Curve RDU NOAA 1yr Storm Frequency = 1 yr Total Rainfall Depth= 2.8300 in Duration Multiplier = 1 Resulting Duration = 23.9999 hrs Resulting Start Time= .0000 hrs Step= .0833 hrs End= 23.9999 hrs Storm Tag Name = 2 Data Type, File, ID = Time -Depth Curve RDU NOAA 2yr Storm Frequency = 2 yr Total Rainfall Depth= 3.4400 in Duration Multiplier = 1 Resulting Duration = 23.9904 hrs Resulting Start Time= .0000 hrs Step= .0833 hrs End= 23.9904 hrs Storm Tag Name = 5 Data Type, File, ID = Time -Depth Curve RDU NOAA 5yr Storm Frequency = 5 yr Total Rainfall Depth= 4.3000 in Duration Multiplier = 1 Resulting Duration = 23.9904 hrs Resulting Start Time= .0000 hrs Step= .0833 hrs End= 23.9904 hrs Storm Tag Name = 10 Data Type, File, ID = Time -Depth Curve RDU NOAA 10yr Storm Frequency = 10 yr Total Rainfall Depth= 4.9800 in Duration Multiplier = 1 Resulting Duration = 23.9904 hrs Resulting Start Time= .0000 hrs Step= .0833 hrs End= 23.9904 hrs Storm Tag Name = 100 Data Type, File, ID = Time -Depth Curve RDU NOAA 100yr Storm Frequency = 100 yr Total Rainfall Depth= 7.3700 in Duration Multiplier = 1 Resulting Duration = 23.9990 hrs Resulting Start Time= .0000 hrs Step= .0833 hrs End= 23.9990 hrs SIN: Bentley Systems, Inc. Bentley PondPack (10.00.027.00) 4:59 PM 10/1/2014 SIN: Bentley Systems, Inc. Bentley PondPack (10.00.027.00) 4:59 PM 10/1/2014 Type.... Tc Calcs Name.... BYPASS Page 3.01 File.... K: \13 \13- 0420 \130427- Northwest Community Church \H -H \Commercial \NWCC - comm.ppw .......................................... ............................... ......................................... ............................... TIME OF CONCENTRATION CALCULATOR ......................................... ............................... ......................................... ............................... Segment #1: Tc: Kirpich (TN) Hydraulic Length 841.00 ft Slope .042000 ft /ft Multiplier 1.000 (Tc Adjustment) Avg.Velocity 2.97 ft /sec Segment #1 Time: .0787 hrs ------------------------------------------------------------------ - - - - -- ------------------ - - - - -- Total Tc: .0787 hrs Calculated Tc < Min.Tc: Use Minimum Tc... Use Tc = .0833 hrs SIN: Bentley Systems, Inc. Bentley PondPack (10.00.027.00) 4:59 PM 10/1/2014 Type.... Tc Calcs Name.... BYPASS Page 3.02 File.... K: \13 \13- 0420 \130427- Northwest Community Church \H -H \Commercial \NWCC - comm.ppw ------------------------------------------------------------------------ Tc Equations used... ------------------------------------------------------------------ - - - - -- Kirpich (TN) Tc = 0.00013 * (Lf* *0.77) * (Sf * *- 0.385) * Mt Where: Tc = Time of concentration, hrs Lf = Flow length, ft Sf = Slope, ft /ft Mt = Tc Multiplier (Tc adjustment) SIN: Bentley Systems, Inc. Bentley PondPack (10.00.027.00) 4:59 PM 10/1/2014 Type.... Tc Calcs Name.... PRE Page 3.03 File.... K: \13 \13- 0420 \130427- Northwest Community Church \H -H \Commercial \NWCC - comm.ppw .......................................... ............................... ......................................... ............................... TIME OF CONCENTRATION CALCULATOR ......................................... ............................... ......................................... ............................... Segment #1: Tc: Kirpich (TN) Hydraulic Length 841.00 ft Slope .042000 ft /ft Multiplier 1.000 (Tc Adjustment) Avg.Velocity 2.97 ft /sec Segment #1 Time: .0787 hrs ------------------------------------------------------------------ - - - - -- ------------------ - - - - -- Total Tc: .0787 hrs Calculated Tc < Min.Tc: Use Minimum Tc... Use Tc = .0833 hrs SIN: Bentley Systems, Inc. Bentley PondPack (10.00.027.00) 4:59 PM 10/1/2014 Type.... Tc Calcs Name.... PRE Page 3.04 File.... K: \13 \13- 0420 \130427- Northwest Community Church \H -H \Commercial \NWCC - comm.ppw ------------------------------------------------------------------------ Tc Equations used... ------------------------------------------------------------------ - - - - -- Kirpich (TN) Tc = 0.00013 * (Lf* *0.77) * (Sf * *- 0.385) * Mt Where: Tc = Time of concentration, hrs Lf = Flow length, ft Sf = Slope, ft /ft Mt = Tc Multiplier (Tc adjustment) SIN: Bentley Systems, Inc. Bentley PondPack (10.00.027.00) 4:59 PM 10/1/2014 Type.... Tc Calcs Name.... TO BMP Page 3.05 File.... K: \13 \13- 0420 \130427- Northwest Community Church \H -H \Commercial \NWCC - comm.ppw .......................................... ............................... ......................................... ............................... TIME OF CONCENTRATION CALCULATOR ......................................... ............................... ......................................... ............................... Segment #1: Tc: User Defined Segment #1 Time: .0833 hrs ------------------------------------------------------------------ - - - - -- ------------------- - - - - -- Total Tc: .0833 hrs Calculated Tc < Min.TC: Use Minimum Tc... Use Tc = .0833 hrs ------------------ - - - - -- SIN: Bentley Systems, Inc. Bentley PondPack (10.00.027.00) 4:59 PM 10/1/2014 Type.... Tc Calcs Name.... TO BMP Page 3.06 File.... K: \13 \13- 0420 \130427- Northwest Community Church \H -H \Commercial \NWCC - comm.ppw ------------------------------------------------------------------------ Tc Equations used... ------------------------------------------------------------------ - - - - -- User Defined Tc = Value entered by user Where: Tc = Time of concentration SIN: Bentley Systems, Inc. Bentley PondPack (10.00.027.00) 4:59 PM 10/1/2014 Type.... Runoff CN -Area Name.... BYPASS Page 4.01 File.... K: \13 \13- 0420 \130427- Northwest Community Church \H -H \Commercial \NWCC - comm.ppw RUNOFF CURVE NUMBER DATA ........................................... ............................... ........................................... ............................... SIN: Bentley Systems, Inc. Bentley PondPack (10.00.027.00) 4:59 PM 10/1/2014 Impervious Area Adjustment Adjusted Soil /Surface Description CN acres %C %UC CN -------------------------- - - - - -- open - - -- 80 --- - - - - -- 2.710 - - - -- - - - -- - - - - -- 80.00 woods 77 2.820 77.00 Impervious Areas 98 .240 98.00 COMPOSITE AREA & WEIGHTED CN - - -> ............................................ ............................................ 5.770 ............................... ............................... 79.28 (79) SIN: Bentley Systems, Inc. Bentley PondPack (10.00.027.00) 4:59 PM 10/1/2014 Type.... Runoff CN -Area Name.... PRE Page 4.02 File.... K: \13 \13- 0420 \130427- Northwest Community Church \H -H \Commercial \NWCC - comm.ppw RUNOFF CURVE NUMBER DATA ........................................... ............................... ........................................... ............................... Impervious Area Adjustment Adjusted Soil /Surface Description CN acres %C %UC CN open 80 5.920 5.00 80.45 woods 77 14.150 77.00 COMPOSITE AREA & WEIGHTED CN - - -> 20.070 78.02 (78) ............................................ ............................... ............................................ ............................... SIN: Bentley Systems, Inc. Bentley PondPack (10.00.027.00) 4:59 PM 10/1/2014 Type.... Runoff CN -Area Name.... TO BMP Page 4.03 File.... K: \13 \13- 0420 \130427- Northwest Community Church \H -H \Commercial \NWCC - comm.ppw RUNOFF CURVE NUMBER DATA ........................................... ............................... ........................................... ............................... SIN: Bentley Systems, Inc. Bentley PondPack (10.00.027.00) 4:59 PM 10/1/2014 Impervious Area Adjustment Adjusted Soil /Surface Description CN acres %C %UC CN -------------------------- - - - - impervious -- - - -- 98 --- - - - - -- 3.440 - - - -- - - - -- - - - - -- 98.00 open 80 8.360 80.00 Future 98 2.500 98.00 Off -Site 80 1.800 60.00 90.80 COMPOSITE AREA & WEIGHTED CN - - -> 16.100 87.85 (88) SIN: Bentley Systems, Inc. Bentley PondPack (10.00.027.00) 4:59 PM 10/1/2014 Type.... Vol: Elev -Area Name.... BMP Page 5.01 File.... K: \13 \13- 0420 \130427- Northwest Community Church \H -H \Commercial \NWCC - comm.ppw Elevation Planimeter Area Al +A2 +sgr(A1 *A2) Volume Volume Sum (ft) (sq.in) ------------------------------------------------------------------------ (sq.ft) (sq.ft) (ac -ft) (ac -ft) 351.00 - - - -- 16428 0 .000 .000 352.00 - - - -- 20161 54788 .419 .419 353.00 - - - -- 21974 63183 .483 .903 354.00 - - - -- 23843 68706 .526 1.429 355.00 - - - -- 25769 74399 .569 1.998 356.00 - - - -- 27751 80262 .614 2.612 POND VOLUME EQUATIONS * Incremental volume computed by the Conic Method for Reservoir Volumes. Volume = (1/3) * (EL2 -EL1) * (Areal + Area2 + sq.rt.(Areal *Area2)) where: EL1, EL2 = Lower and upper elevations of the increment Areal,Area2 = Areas computed for EL1, EL2, respectively Volume = Incremental volume between EL1 and EL2 SIN: Bentley Systems, Inc. Bentley PondPack (10.00.027.00) 4:59 PM 10/1/2014 Type.... Outlet Input Data Name.... Outlet 1 Page 6.01 File.... K: \13 \13- 0420 \130427- Northwest Community Church \H -H \Commercial \NWCC - comm.ppw REQUESTED POND WS ELEVATIONS: Min. Elev.= 351.00 ft Increment = .20 ft Max. Elev.= 356.00 ft OUTLET CONNECTIVITY - - -> Forward Flow Only (UpStream to DnStream) < - -- Reverse Flow Only (DnStream to UpStream) < - - -> Forward and Reverse Both Allowed Structure ----------- - - - - -- No. - - -- Outfall - - - - - -- E1, ft --- - - - - -- E2, ft --- - - - - -- Weir- Rectangular WO - - -> CO 352.500 356.000 Inlet Box RO - - -> CO 353.500 356.000 Orifice - Circular 00 - - -> CO 351.000 356.000 Culvert - Circular CO - - -> TW 344.000 356.000 TW SETUP, DS Channel SIN: Bentley Systems, Inc. Bentley PondPack (10.00.027.00) 4:59 PM 10/1/2014 Type.... Outlet Input Data Name.... Outlet 1 Page 6.02 File.... K: \13 \13- 0420 \130427- Northwest Community Church \H -H \Commercial \NWCC - comm.ppw OUTLET STRUCTURE INPUT DATA Structure ID Structure Type -------- - - - - -- # of Openings Crest Elev. Weir Length Weir Coeff. WO Weir - Rectangular ---------------- 1 352.50 ft 6.00 ft 3.100000 Weir TW effects (Use adjustment equation) Structure ID = RO Structure Type = Inlet Box ------------------------------------ # of Openings = 1 Invert Elev. = 353.50 ft Orifice Area = 25.0000 sq.ft Orifice Coeff. _ .600 Weir Length = 14.00 ft Weir Coeff. = 3.100 K, Reverse = 1.000 Mannings n = .0000 Kev,Charged Riser = .000 Weir Submergence = No Structure ID = 00 Structure Type = Orifice- Circular ------------------------------------ # of Openings = 1 Invert Elev. = 351.00 ft Diameter = .2083 ft Orifice Coeff. _ .600 SIN: Bentley Systems, Inc. Bentley PondPack (10.00.027.00) 4:59 PM 10/1/2014 Type.... Outlet Input Data Name.... Outlet 1 Page 6.03 File.... K: \13 \13- 0420 \130427- Northwest Community Church \H -H \Commercial \NWCC - comm.ppw OUTLET STRUCTURE INPUT DATA Structure ID = CO Structure Type = Culvert - Circular ------------------------------------ No. Barrels = 1 Control K = Barrel Diameter = 3.0000 ft Upstream Invert = 344.00 ft Dnstream Invert = 342.15 ft Horiz. Length = 187.00 ft Barrel Length = 187.01 ft Barrel Slope = .00989 ft /ft OUTLET CONTROL DATA... Mannings n = .0130 Ke = .5000 Kb = .007228 Kr = .5000 HW Convergence = .001 INLET CONTROL DATA... Equation form = 1 Inlet Control K = .0098 Inlet Control M = 2.0000 Inlet Control c = .03980 Inlet Control Y = .6700 T1 ratio (HW /D) = 1.155 T2 ratio (HW /D) = 1.302 Slope Factor = -.500 (forward entrance loss) (per ft of full flow) (reverse entrance loss) +/- ft Use unsubmerged inlet control Form 1 equ. below T1 elev. Use submerged inlet control Form 1 equ. above T2 elev. In transition zone between unsubmerged and submerged inlet control, interpolate between flows at T1 & T2... At T1 Elev = 347.47 ft - - -> Flow = 42.85 cfs At T2 Elev = 347.91 ft - - -> Flow = 48.97 cfs Structure ID = TW Structure Type = TW SETUP, DS Channel ------------------------------------ FREE OUTFALL CONDITIONS SPECIFIED CONVERGENCE TOLERANCES... Maximum Iterations= 40 Min. TW tolerance = .01 ft Max. TW tolerance = .01 ft Min. HW tolerance = .01 ft Max. HW tolerance = .01 ft Min. Q tolerance = .00 cfs Max. Q tolerance = .00 cfs SIN: Bentley Systems, Inc. Bentley PondPack (10.00.027.00) 4:59 PM 10/1/2014 Type.... Composite Rating Curve Name.... Outlet 1 Page 6.04 File.... K: \13 \13- 0420 \130427- Northwest Community Church \H -H \Commercial \NWCC - comm.ppw * * * ** COMPOSITE OUTFLOW SUMMARY * * ** WS Elev, Total Q Notes ---------- - - - - -- -- - - - - -- Converge ------------------------- Elev. Q TW Elev Error ft cfs ft + / -ft Contributing Structures -- - - - - -- 351.00 - - - - - -- .00 -- - - - - Free -- - - - -- Outfall -------------------------- (no Q: WO,RO,OO,CO) 351.20 .05 Free Outfall OO,CO (no Q: WO,RO) 351.40 .09 Free Outfall OO,CO (no Q: WO,RO) 351.60 .11 Free Outfall OO,CO (no Q: WO,RO) 351.80 .14 Free Outfall OO,CO (no Q: WO,RO) 352.00 .15 Free Outfall OO,CO (no Q: WO,RO) 352.20 .17 Free Outfall OO,CO (no Q: WO,RO) 352.40 .19 Free Outfall OO,CO (no Q: WO,RO) 352.50 .19 Free Outfall OO,CO (no Q: WO,RO) 352.60 .79 Free Outfall WO,OO,CO (no Q: RO) 352.80 3.24 Free Outfall WO,OO,CO (no Q: RO) 353.00 6.70 Free Outfall WO,OO,CO (no Q: RO) 353.20 10.88 Free Outfall WO,OO,CO (no Q: RO) 353.40 15.65 Free Outfall WO,OO,CO (no Q: RO) 353.50 18.23 Free Outfall WO,OO,CO (no Q: RO) 353.60 22.32 Free Outfall WO,RO,OO,CO 353.80 33.78 Free Outfall WO,RO,OO,CO 354.00 48.08 Free Outfall WO,RO,OO,CO 354.20 64.56 Free Outfall WO,RO,OO,CO 354.40 82.95 Free Outfall WO,RO,OO,CO 354.60 96.48 Free Outfall WO,RO,OO,CO 354.80 101.89 Free Outfall WO,RO,OO,CO 355.00 104.87 Free Outfall WO,RO,OO,CO 355.20 106.56 Free Outfall WO,RO,OO,CO 355.40 107.61 Free Outfall WO,RO,OO,CO 355.60 108.65 Free Outfall RO,CO (no Q: WO,O0) 355.80 109.69 Free Outfall RO,CO (no Q: WO,O0) 356.00 110.71 Free Outfall RO,CO (no Q: WO,O0) SIN: Bentley Systems, Inc. Bentley PondPack (10.00.027.00) 4:59 PM 10/1/2014 Appendix A Index of Starting Page Numbers for ID Names - - - -- B ----- BMP... 5.01 BYPASS... 3.01, 4.01 - - - -- 0 - - - -- Outlet 1... 6.01, 6.04 - - - -- P ----- PRE ... 3.03, 4.02 - - - -- R - - - -- RDU 24 Hour Desi... 2.01 - - - -- T - - - -- TO BMP... 3.05, 4.03 - - - -- W ----- Watershed ... 1.01 A -1 SIN: Bentley Systems, Inc. Bentley PondPack (10.00.027.00) 4:59 PM 10/1/2014 Survey linear wetland (not flagged) 22 tt 16 , l Project No. 12088.WI Project Mgr.: 515 Scale: I" =300' 5/14/13 Legend Pond Site should be reviewed by USACE and Town of Cary Jurisdictional Wetland S03 Start CH .X.. _ W G;7 Possbily isolated 15 tt 08 (may be isolated) 01 -07 tt PL Wetland may be isolated Figure 3- Wetland Sketch Map NW Comm Church Wake County, NC Wake County G15 Weak Soils Marginal Wetland Evaluation Area o Unimportant Intermittent ® Jurisdictional Linear Wetland S02 Start linear wetland 23 -25 tt CH (may be off property) May be isolated pond in high ground 36 26 &59tt PL Detailed Delineation of Waters of the US Suitable for Preliminary Planning ONy S &EC rcawes the right b, modify this map based on more ➢eltlwork, and any d➢rer additional informa[wn. Apprordmatione were mapped using topographic maps, air photos and ground IruNing. h the site is goivg m be disturbed, S &EC's deta➢e➢ delineation should be approved and P,rmitted by the U.S. Army Corps of Engineers as regviretl. U [he user of Chia work desires an accurate map of the regulated featwea flagged by S &EC, they should retain a rvC Registered Profeeaional Land Surveyor [a ' locate SffiEC's ➢agging. ------ .I_..1�110 11 I &: Etivironme°ntal Consultants,, F'1 11010 Raven Ridge Rd.- Raleigh, NC 2;'614 (919) 846 -5900 a (919) 8 46-946 7 Ofeb Page: ivww.:iandEC.corn 0 w z Q- a rn 0 a a 0 N N O 0 u 0 0 a w 0 0 0 i U 3 z i 0 110111161 SITE PLANS FOR U J � U O ED r. � � M C' � N Z :2 O O Q U [if O O UI Z Z w 0=w U af 0 Oaf rh Z d TFiVVEST (ZC)MMLJ 41T)( (zFiLil (zFi N .. 2af 00-d u LL- CADV KIC"IDT" CADC"11 IKIA INDEX OF SHEETS SHEET # TITLE SHEET # TITLE FIRST SUBMITTAL: JULY 9, 2014 C0.0 COVER SHEET SD -302 CHAPEL COMPOSITION OVERLAY 0.2 EXISTING CONDITIONS SD -303 CHAPEL SCALE OVERLAY SECONDSUBMITTAL: OCT 2 2014 0.1 EXISTING CONDITIONS SD -304 CHAPEL PROPORTION OVERLAY / C2.0 SITE PLAN SD -305 CHAPEL RHYTHM OVERLAY VICINITY MAP �r � � C2.1 DETAILED SITE PLAN SD -306 CHAPEL TRANSPARENCY OVERLAY r ` I� / C3.0 UTILITY PLAN SD -307 CHAPEL ARTICULATION OVERLAY C3.1 DETAILED UTILITY PLAN SD -308 CHAPEL EXPRESSION OVERLAY C4.0 GRADING PLAN SD -309 CHAPEL COLOR OVERLAY C4.1 DRAINAGE PLAN C5.0 PRE DEVELOPMENT EROSION CONTROL PLAN OJ C5.1 POST DEVELOPMENT EROSION CONTROL PLAN �!� C6.0 R001 PLAN AND PROFILE � \ ��� 'T I C6.1 R001 PLAN AND PROFILE ���� C7.0 STORMWATER MANAGEMENT PLAN Y - - - - -- MORRISVILLE PKy C8.0 STORM AND EROSION CONTROL DETAILS MORRISVILLE P Y �� ` C8.1 UTILITIES DETAILS 1 1 C8.2 UTILITIES AND SITE DETAILS I I SITt I 0 1 C8.3 SITE DETAILS 1-1.0 OVERALL LANDSCAPE PLAN C � 1 I L1.1 LANDSCAPE NOTES AND DETAILS L2.0 LIGHTING PLAN JIW 0 M I n I N , ` I - SD -101 WORSHIP BUILDING FLOOR PLAN I I I I 0 SD -200 WORSHIP BUILDING ELEVATION ti O y CHURCH I I / / SD -201 WORSHIP BUILDING MATERIAL OVERLAY ri z SD -202 WORSHIP BUILDING COMPOSITION OVERLAY tiG I SITE I / � C: SD -203 WORSHIP BUILDING SCALE OVERLAY X �I I V SD -204 WORSHIP BUILDING PROPORTION OVERLAY / SD -205 WORSHIP BUILDING RHYTHM OVERLAY SD -206 WORSHIP BUILDING TRANSPARENCY OVERLAY S n t S SD -207 WORSHIP BUILDING ARTICULATION OVERLAY C� / I I� SD -208 WORSHIP BUILDING EXPRESSION OVERLAY SD -209 WORSHIP BUILDING COLOR OVERLAY SD -301 CHAPEL MATERIAL OVERLAY ROAD CLASSIFICATION: SD -302 CHAPEL COMPOSITION OVERLAY POSTED SPEED DESIGN SPEED LENGTHS: I ' ROADWAY CLASSIFICATION I I _ NOTES: (MPH) (MPH) (LF) I - 1. UNLESS EXPLICITLY SPECIFIED IN THE NOTES ON THIS SITE PLAN, THE DEVELOPMENT OF THIS PROJECT, R001 MAJOR LOCAL (PRIVATE) 25 25 1616 _ _ INCLUDING ANY SUBSEQUENT SITE PLANS, SHALL COMPLY WITH THE CARY LAND DEVELOPMENT ORDINANCE (LDO) AND ALL OTHER APPLICABLE REGULATIONS AND GUIDELINES. IN THE EVENT OF A DISCREPANCY BETWEEN THIS APPROVED SITE PLAN AND THE APPLICABLE REGULATIONS OR GUIDELINES, AND ABSENT PLAN OR OTHER RELATED APPROVAL, THE APPLICABLE REGULATION OR GUIDELINE SHALL I r I I l I APPLY. PROJECT SPECIAL CONDITIONS I I- :�:�" � I 2. NO CHANGES TO ANY ASPECT OF THIS SITE PLAN, INCLUDING BUT NOT LIMITED TO, LANDSCAPING, �/ I I GRADING, ARCHITECTURAL DESIGN (ESPECIALLY COLORS), LIGHTING, OR UTILITIES SHALL BE MADE 1. THIS PROJECT HAS THE FOLLOWING REZONING CONDITIONS PER CASE 13- REZ -29: I I `..:._ -' J i I I I WITHOUT THE APPROVAL OF THE DEVELOPMENT REVIEW COMMITTEE OF THE TOWN OF CARY. 3. THE ESTABLISHMENT OF PERMANENT GROUND COVER WILL BE ESTABLISHED IN 15 WORKING DAYS OR 1.1. USES SHALL BE LIMITED TO RESIDENTIAL AND /OR RELIGIOUS ASSEMBLY USES. I I f )� •� 90 CALENDAR DAYS, WHICH EVER IS FIRST. 1.2. RESIDENTIAL USE SHALL BE LIMITED TO A MAXIMUM OF 48 DETACHED DWELLINGS. I I I W E 4. THE REQUEST FOR DEVELOPER AGREEMENT WILL BE SUBMITTED PRIOR TO BIDDING THE PROJECT OR 1.3. RELIGIOUS ASSEMBLY USE SHALL NOT EXCEED 20,000 SF. I I THE DEVELOPER FORFEITS THEIR REQUEST FOR A DEVELOPER AGREEMENT. 1.4. ANY RELIGIOUS ASSEMBLY ACCESSORY DAY CARE OR SCHOOL USE SHALL BE LIMITED TO NO I 5. THE DEVELOPER WILL BE RESPONSIBLE FOR ALL INSTALLATION COSTS ASSOCIATED WITH STREET LIGHTING S MORE THAN 38 CHILDREN OR STUDENTS. I , �� ALONG PROPOSED STREETS ADJACENT STREETS AND THOROUGHFARES AS REQUIRED PER TOWN OF 2. ROAD IMPROVEMENT NOTES CARY STATEMENT No.13. THE DEVELOPER SHALL CONTACT PROGRESS ENERGY AFTER PLAN APPROVAL ROAD IMPROVEMENTS TO WHITE OAK CHURCH RD AND MORRISVILLE PKY. ARE SHOWN ON THE AND PRIOR TO CONSTRUCTION IN ORDER TO DEVELOP A STREET LIGHTING PLAN FOR THE ESTATES AT PATES POND (F.K.A. HOWARD /EMERSON SUBDIVISION) PROJECT (14 -SB -014) AND THE SITE SUBDIVISION PLANS. D E V E L O P E WOWNER FRONTAGE OF THE NORTHWEST COMMUNITY CHURCH SITE. THE IMPROVEMENTS ALONG THE 6. THIS DESIGN MEETS ALL CURRENT TOWN OF CARY STANDARD SPECIFICATIONS AND DETAILS EXCEPT FRONTAGE OF THE RESIDENTIAL AND NORTHWEST COMMUNITY CHURCH SITE (NWCC) WILL BE WHERE SPECIFICALLY NOTED BELOW: COMPLETED BY EACH RESPECTIVE PROJECT USING THE 14 -SB -014 PLAN SET. THE FIRST • NONE CERTIFICATE OF OCCUPANCY FOR THE SINGLE FAMILY RESIDENTIAL WILL NOT BE ISSUED UNTIL THE 9. THE GRADING PERMIT WILL NOT BE ISSUED UNTIL THE TOWN OF CARY HAS RECEIVED NOTIFICATION ROAD IMPROVEMENTS ALONG THE FRONTAGES OF THE ESTATE AT YATES POND (F.K.A NORTHWEST COMMUNITY CHURCH FROM THE ECOSYSTEM ENHANCEMENT PROGRAM OR AN APPROVED NUTRIENT OFFSET BANK THAT A HOWARD /EMERSON SUBDIVISION) ARE COMPLETED AND THE CERTIFICATE OF OCCUPANCY WILL NOT BE ISSUED FOR THE CHURCH UNTIL ROAD IMPROVEMENTS ALONG THE CHURCH FRONTAGES IS RECIPT HAS BEEN ISSUED TO THE DEVELOPER AND THE LOCAL GOVERNMENT STATING THE NITROGEN COMPLETED. IF THE NWCC SITE DOES NOT GO TO CONSTRUCTION CONCURRENTLY, THEN A BUY DOWN HAS BEEN COMPLETED. IF REQUIRED. PHASING PLAN FOR THAT PORTION OF THE ROAD IMPROVEMENTS WILL BE SUBMITTED TO THE TOWN 10109 MORRISVILLE PKWY 10. SIGN PERMITTING IS A SEPARATE APPROVAL PROCESS AND HAS NOT BEEN REVIEWED OR APPROVED OF CARY AND NCDOT FOR APPROVAL. APEX NC 27523 WITH THIS SITE PLAN. A MASTER SIGN PLAN SHALL BE APPROVED BY THE PLANNING DEPARTMENT 3. SEWER SYSTEM PRIOR TO ISSUANCE OF ANY CERTIFICATE OF OCCUPANCY (CO) WITHIN THE DEVELOPMENT. 3.1. THIS PROJECT DEPENDS ON MULTIPLE DOWNSTREAM SEWER FACILITIES BEING APPROVED, ATTN: MR. JOEL CARPENTER 11. DEVELOPER IS RESPONSIBLE FOR FOR COORDINATING ATT CONNECTION APPROVAL WITH ALL CONSTRUCTED AND ACCEPTED BY THE TOWN OF CARY. UPON COMPLETION OF THE PROJECTS APPROPRIATE JURISDICTIONS, COUNTY, NCDOT, ETC. LIST BELOW, THE TOWN OF CARY WILL ACCEPT THE SEWER SHOWN IN THIS SITE PLAN FOR 12. THE FOLLOWING MINOR MODIFICATIONS TO THE TOWN'S DEVELOPMENT STANDARDS HAVE BEEN APPROVED ACTIVE FLOW. IN ACCORDANCE WITH SECTION 3.19 AND OTHER APPLICABLE SECTIONS OF THE LDO: 3.1.1. CONSTRUCTION OF GRAVITY SEWER OUTFALL AND THE PINE RAIL LN PUMP STATION WITH FORCEMAIN DISCHARGING TO TOWN OF CARY GRAVITY SEWER SYSTEM. OR NONE 3.1.2. CONSTRUCTION OF TWO TEMPORARY PUMP STATIONS ON SITE WITH FORCEMAIN(S) SEE SEPARATE SITE PLAN # (14- SP -XXX) DISCHARGING TO THE TOWN OF CARY GRAVITY SEWER SYSTEM AT THE WHITE OAK CHURCH SEWER OUTFALL (TOC PROJ # 14 -SP -051). PREPARED BY: 3.1.3. CONSTRUCTION OF WHITE OAK CHURCH SEWER OUTFALL AND CONNECTION TO THE EXISTING GREEN LEVEL INTERCEPTOR (TOC PROJ. #14 -SP -051). 4. CHAMPION TREE 4.1. IF ANY OF THE CHAMPION TREES RETAINED IN THIS PLAN DIE WITHIN ONE YEAR OF THE Q COMPLETION OF DEVELOPMENT ACTIVITY ON THE PROPERTY, THE OWNER SHALL BE REQUIRED Town of Cary TO REPLACE THAT TREE IN ACCORDANCE WITH SECTION 7.2.5 (D) OF THE LAND DEVELOPMENT WITHERS RAVENEL Engineering Department KNOW WHAT'S BELOW. ORDINANCE. ``°° CALL BEFORE YOU DIG. 4.2. PER SECTION 7.2.5(D) OF THE LDO, TREES IDENTIFIED AS REPLACEMENTS FOR CHAMPION Approved Utility Extensions ��> �N Rp , PERIOD rOFBAT�EgO�ED FROM THREPLACEMENT BE REESI THAT THROUGH AN SURVIVEESTABLISHMENT ENGINEERS I PLANNERS I SURVEYORS Water Permit # ° �pFESSQ ; ESTABLISHMENT PERIOD SHALL BE REPLACED BY THE DEVELOPER. �p Cary Project Number 14 -SP -049 115 MacKenan Drive Cary, North Carolina 27511 tel: 919 - 469 -3340 www.withersravenel.com License No. C -0832 Sewer Permit # P �I I \Y Cary HTE Number 15 -0029 Revision Date B E L By' NOT APER VE02WO6CO SfRUCTION Approved by the Town of Cary Development Review Committee FNGINEE� ° '' ° ° °1!.-81A RD A Po% Planner Dote 0 0 V1 D 0 U U 3 m W J �I o 0 I, THOMAS M. GRZEBIEN, CERTIFY THAT THIS PLAT WAS DRAWN UNDER MY SUPERVISION FROM AN ACTUAL SURVEY MADE UNDER MY SUPERVISION (DEED DESCRIPTIONS RECORDED IN BOOK /PAGE AS SHOWN UNDER \ -\ \ RBFC 3/4" IPF "SOURCE OF TITLE "); THAT THE BOUNDARIES NOT SURVEYED ARE CLEARLY INDICATED AS DRAWN FROM INFORMATION SHOWN ON THE FACE OF THIS MAP; THAT THE RATIO OF PRECISION AS CALCULATED IS \ CMF 1:10,000 +; AND THAT THIS PLAT WAS PREPARED IN ACCORDANCE WITH G.S. 47 -30 AS AMENDED. WITNESS \ \FERRELL RD., S.R. 1 627 ■ MY ORIGINAL SIGNATURE, REGISTRATION NUMBER, AND SEAL THIS DAY OF A.D. 20 -. \ \ ( 1 10' PUBLIC RIM j U PRELIMINARY MAP THOMAS M. GRZEBIEN, P.L.S. # 4695 \ RBFC FOR REVIEW PURPOSES ONLY �\ -P NORTHWEST COMMUNITY \\ NOWORFORMERLY `y CHURCH OF CARY, INC DB 15709, PG. 2202 PIN: 0724 -14 -8044 I, THOMAS M. GRZEBIEN, PROFESSIONAL LAND SURVEYOR # 4695, CERTIFY THAT: \ WAKE ZONING: R40W THIS PLAT IS OF A SURVEY OF AN EXISTING PARCEL OR PARCELS OF LAND AND DOES NOT CREATE A \ . \ / (TRACT 'l PER HOWARD x\ D NEW STREET OR CHANGE AN EXISTING STREET. \ j / II BOUN ARY SURVEY BY WSP; PRELIMINARY MAP SEE "MAP REFERENCES ") \ �\ THOMAS M. GRZEBIEN, P.L.S. # 4695 FOR REVIEW PURPOSES ONLY R DISC / I, THOMAS M. GRZEBIEN, CERTIFY THAT THIS PROJECT WAS COMPLETED UNDER MY DIRECT AND RESPONSIBLE CHARGE FROM ACTUAL GROUND AND AIRBORNE SURVEYS MADE UNDER MY SUPERVISION; THAT THE \ / RBFC HORIZONTAL AND VERTICAL ACCURACIES MEET OR EXCEED THE NATIONAL MAP ACCURACY STANDARDS; THAT ° THE DATA WAS OBTAINED BETWEEN OCTOBER 16, 2013 AND FEBRUARY 3, 2014; THAT THE SURVEY WAS COMPLETED ON FEBRUARY 5, 2014; AND THAT ALL PRELIMINARY L A RE BASED ON NAVD88. MAP P / II UP \ f° THOMAS M. GRZEBIEN, P.L.S. # 4695 DATE / II / FOR REVIEW PURPOSES ONLY NOW OR FORMERLY / / SINK HOLE - /DID ° / / ' II / / N T HIT IPE F NORTHWEST COMMUNITY CHURCH / / BOTTOM LEV: 73.4' F° CMF■ OF CARY, INC / / rr DB 15709, PG. 2202 J II / Fo PIN: 0724 -14 -8044 / / W / ' L - WAKE ZONING: R40W /II / � / PINE 1 +� -PINE °� �a� - • - _ . _ _ - (TRACT 'C' PER HOWARD BOUNDARY �R /W rr UPrr - _ _ SURVEY BY WSP; SEE "MAP REFERENCES ") / / II / . / \ // ,� ••• '• �aOUt- _a_ _ /' PINE 8 _ / S � RBFC a� �a� i� // lO / 4 Fpo CA - �-� � a RBFC � //� a UfZ II - � / \vJ� _ .• IN PINE 12 _ PI .- � E 0 �� _ - - -- - NE 14 - - - °/� PINE 13 -PINE 15 1/2" IPF CMF NOW OR FORMERLY ♦RBFC \ \ BETTY L. LANIER 11 /4" IPF and husband NOTE: SEE SHEET 0.2 FOR 1 VIRGIL W. LANIER L6 IN6 72 34- 16 r� WAKE ZONING: R 40W THE GENERAL NOTES , C LEGEND, AND TITLE, MAP, / NOW OR FORMERLY KAYE MANGUM HOWARD EASEMENT AND ZONING B C F° J DB 13188, PG. 1610 PIN: 0724 -34 -1025 7 �CME .•T F ° 11 11 n 3,959 S.F. ! WAR ACRES REFERENCES (TRACT'S' PER HOWARD BOUNDARY SURVEY BY WSP; SEE "MAP \ \ : REFERENCES ") �-� \ \ RBFC \ \ OF \ \ o o C F5 \ ` \ 9/16" IPF \ '\ ASPHALT 0.55' NE OF CP \ P ATH 1 :\ \ E I E 1 � \+PI E 3 IN 1 i\ \ PINE 12 PINE 13' PIN 1� *PINE 15 13 NE 21 1 \ C 0 1 REIS (S R/W OF SR 1600 & W R/W OF ATT) S15'5 '46 "E, 36.54 1 1 514'46' 2 "E, 169.71' CMFf 1111 111 \': ? 0 +OAK 21 1 1� 1 n 1 I -A 1 Fo (60. P 15 RCP- F- 41 SPINE 16 (P 11 11 SBT &T UTILITY POLE : UP -&PINE 12 E 1 " % - -- - - 18" RCP Fo- •, ...375.58 • ' / F RB COMPUTED CORNER TO CMF3:-. N50'06'23 "W, 0.$8' / CMF3 iCOMPUTED CORNER -TO CMF4: N74'10'11 "W, 1.65' / 1.5 STORY 378. 5' a BRICK HOUSE / a PATIO U K I / .: ELL Al ;SEPTIC LO _ / Up rr rr ;UP I n: SHELTER......... / r379.03' CO T'' -�� WELL PUMP / - v . ... - - -- - GRAVEL DRIVE I / 379.45' of o /_/ / M� I l a n 379.20' W C L 30" f 1 ...... �UP � .............. 378.57`: 376.08' CL 377.59' a COMPUTEI . �/ / /. •••�••• F21 L1 .COMPUTED CORNER TO�CMF2 (B N): N7T43'38 "W, 1.37 CMF1 / COMPUTED CORNER TO C (CHIPPED): N84 37 23 W 1.11' COMPUTED CORNER C t0 (CHIPPED): 584'22'20 "W, 1.08,- 601 0 rn 30' CP &L EASEMENT; � -DB 1935, PG. 618 : N { / / / /:• DB 2185, PG. 451 NO PER'DB 3315, G. 457, THE RIGHT- F -WAY OF WHIT OAK CHURCH ROAD / :.z THROU H THE NWCC T CT WAS ESTABLISHED USING 0TH 25' AND 0' RIGHT LEFT OFFSETS" RIGHT/ LEFT % -/ ;OF TH CENTER OF AVEMENT AS LOCATED I o DURI G ',THE COURSE OF THI S SURVEY._ C i 35" WHITE OAK 1 ° 18" i 473.76' 18° RCPT' ,374.78 .... RIP ...... " •. I ` � UNDERGROUND DROP DIRECTION UNKNOWN 31 M ........ I \ m 30' C &L EASEMENT / 154DB 19 , PG. 618�� DB 2185, PG. 451 / 0 / a I 3 I � LLJ / NO E: PER DB 3315, PG. 457, T RIGHT -OF -WAY OF WHITE 11 F. AK CHURCH ROAD THROUGH I THE NWCC TRACT WAS : UP GRAVEL /ASPHALT DRIV E SES /W r NORTH OF PROPERTY INE A D C SSE E TABLISHED' USING BOTH 25' l PROPERTY LINE 58' E ST OF R /W) A D 30' RIGHT /LEFT OFFSETS 0 THE CENTER OF PAVEMENT i RBFC _ - -_ S LOCATED DURING THE - 74.91' URSE OF THIS SURVEY.' ����I_ I i L 1* I L� OB I II ^�� : I I I I \ \ • APPEARS TO BE ABANDONED; 1 -PINE 11 NO SBT &T EASEMENTS FOUND ■CMF (SEE GEN. NOTE E GUY ANCHOR ONLY (NO ES -ro _ / - /CONNECTED TO POLE) 377.97 5 RC 377.72' -PINE 22' NOTE: PER DB 2071 PG. 474 AND DB 22 0 PG. 469 UNDERGROUND DROP +OAK 27 DIRECTION UNKNOWN THE RIGHT -OF -WAY OF MORRISVILLE PAR AY THROUGH UP RIG T/ EFTCOFFFSET OF A THE S CENTER IED PAVEMENT AS SEMENT DB 1935, PG. 618 -GUM 16 DB 216s, Pc. 451 l� +GUM 1 LOCATED DURING THE COURSE OF HIS SURVEY. \\ M GUM 20+ +GUM 28 �- -PINE 11 0 \, 1 I 1 j1 3;1 1 r 1 1 PINE 12 INE 14 I 1 1 1 1: :1 1:• OAK 1,++PIN 16 : 1 1 '• it li .1 I: j1 1 1 II I. +PINE 14 1 I - 1 1 1 1' �-Gl 20 I .:GUM 1 .INE 24 I 1: 1 1 I A-}OAK 23 ULTIVATED FI �\ w/ S LE WIRE FENCE /' 'o FEIJCE POST (TYP \ i , f • �� POND 2 � � '•.,• � • /� �� � .. i ' \(SEE GEN. NOTE #8) WATER ELEVATION AS \ OF 12/17/13: 367.2' NORT EST COMMUNI DB 15709 PG. 2202 022,PIN: 0724 -23 -0269 54 S.F. / 23.472 j / DILAPI TED B RBED WIRE ENCE R MNANT N88'S9 4 W ............. " � ..' 440.00' 4' WHITE O��AKK", 11 , „ .. r ,. UM)12< \_\ \ 1 1 ': � 1 +PINE 13 RBFC 11 11 \ - 12.15 PINE 10+ 1/2" IPF •:1� 11 �: \ \ \\ �. (q 1 i V - GUM 13+ PINE 11+ m 11 •t PINE 14 + + 0 1 1 •, I �•\ \ PINE 16 X m 95.92, 1 1 I +PINE 10 Co I 1 :1 1 co I -PINE 0 PINE 16 RBFC ........_�� +PINE 19 1 1 EI li INE 14 \ IE \ PINE 13 .. - -- PINE 4�4* it li �- +PINE 15 I 1 it 1: -PINE 15 +OUM 12 1 1: \ PINE 12 1 ; \ \ -GUM 11 INE 16 1 1: POPLAR 20 I li POPLAR 20 O I I I ;I li I^ u 1 I �I I: UM 1\ I 1 1 i INE I 1 1 1 INE 1 II 11 E +OAK 12 I I I i I ,.,. OAK 11 \ +OAK 19 EI I: \ I I -PINE 17 I I t I it I, I EI I. EI I. i y I Ak 16 AK i + � 1/2" OF I I AK fV EI I E IE AK 5 �� -i / E� (• I I HI KO�R,Y 15 11 2Y 2 I I it � I I• E 11 Uj E I• I I o ) i III i 11 �O NOW RFORMERLY - 11� lq COP ERL AF CO,MMU,NITY 13 II E SSOCIATION, INC. ? II E (CO MON OPEN SPACE) B 14128' PG ' 620 PIN: 0724 -33 -1006 II' �Y 13 CA Y ZONING: PDDMajor E I( ' !I R12+ kOAK 17 3UM 15 ii 1 I N8951105 140.97' (77E) I 4 OR TTW OU WAKE F AIRDB 9561 PIN072 I'�I CARY ZONING: R/R WIF 3) i � �WF53 / LINE TABLE LINE LENGTH BEARING L1 5.00 N89 °39'32 "W L2 61.13 N49 °16'52 "E L3 63.16 S83 °40'1 0 "E L4 28.74 N52 *19'50 "E L5 76.00 N52 *19'50 "E L6 1.03 S88-26'1 8"E L7 155.01 S11'18'24 "W CURVE TABLE CURVE RADIUS LENGTH DELTA BEARING DISTANCE C1 14843.13 230.41 0 °53'22" NO2'40'36 "E 230.41 C2 4277.38 106.17 1'25'20" S84 °22'48 "E 106.16 C3 947.44 620.54 37 °31'37" N76 °08'42 "E 609.51 C4 2192.39 193.28 5 °03'04" N54 °51'21 "E 193.22 C5 3769.72 457.09 1 6 °56'50" N13 °07'04 "W 456.81 C6 13869.721 110.05 1 1 °37'46" N16'20'47 "W 110.04 0i o Z N r M ¢ 00 w o m¢ � z 00 Cn c� ¢ U M Z GRAPHIC SCALE 60 0 30 60 120 ( IN FEET ) 1 inch = 60 ft. 14 -SP -049 HTE #: 15 -0029 APPROVED BY THE TOWN OF CARY DEVELOPMENT REVIEW COMMITTEE PLANNER Date 0 0owsp ,.,o,- 0,0 15401 Weston Parkway Suite 100 Cary, NC 27513 919.678.0035 www.wspgroup.com /usa PRELIMINARY NOT RELEASED FOR CONSTRUCTION INC LICENSE # F -0891 z 01 U Z f1 0 t.J Q J 0 0 �o Q Q zQ� U U Uj� Uj C'4 G U LL z OWE O V zQ L U U z U W wU / N ti U N= I..L Z O U z 0 Z REVISIONS 1 2 3 PROJECT #:11370024.000 DATE: 5/20/14 DRAWN BY: JMS/TMG CHECKED BY: TMG TITLE EXISTING CONDITIONS SHEET 0.1 NOW OR FORMERLY SANDRA B. EMERSON DB 7068, PG. 354 PIN: 0724 -24 -8313 WAKE ZONING: R -40W 1/2" IPF IPF"\ X27 ■cMF U - ORMERLY \\ COMMUNITY�� F CARY, INC PG. 2202 4 -14 -8044 IING: R -40W o IER HOWARD 0 JRVEY WSP; i EFERENC ES ") V N \\ O \\ x U I C U ' C ' v a , 0 30' CP &L EASEMENT DB 3221, PG. 166 / q/ NOW OR FORMERLY MASUD BEROZ DB 14410, PG. 1277 PIN: 0724 -34 -4670 / WAKE ZONING: R -40W U /�j� /�\ \ 7 u / wY Aklz up ti UP / 696h UP OO \ NOW OR FORMERLY ■CMF•' +. WILLIAM A. FERRELL ./ QF F G "IPF G� O� DORIS and WIFE P. FERRELL / F° QP 369.76 -70 NOW OR FORMERLY n 7 \ DB 1928, PG. 639 �� / y COPPERLEAF COMMUNITY PIN: 0724 -34 -1418 / y1� � ASSOCIATION, INC. O WAKE ZONING: R -40W - cj ,'.I, p (COMMON OPEN SPACE) - / F° GQ �% DB 14128, PG. 620 -A \ / PIN: 0724 -34 -7254 0 370.61' ASPHALT DRIVE "END" PAINTED CARY ZONING: PDDMajor U IN YELLOW GAS LINEPAI / 372.3 ' \ NOTE: NO EASEMENT FOUND i/ �g Q �o �`•. /I �- 372.3 ' Fo CMF -w_30' CP &L EASEMENT DB 3221, PG. 166 \ \ I CMF Zzz O� \ \ / " \ \ CMF • NOW OR FORMERLY / RBFC \\ \\ ��' F° BETTY L. LANIER \ 1 /4" IPF and husband VIRGIL W. LANIER L6 % -- DB 6445, PG. 277 PIN: 0724-34-3162 WAKE ZONING: NG: R -4 0W I I RBFC� I ' M/ I;r' OF F, N— //� ■0 001 U 3 ,. •' •�' PINE 1 + PINt1 J �I a 0 0 CMF■ +PINE 15 PINE 15+ +PINE 13 RBS (S R/W T CMF TO +OAK 21 NOW OR FORMERLY KAYE MANGUM HOWARD F °�I DB 13188, PG. 1610 yI PIN: 0724 -34 -1025 3,959 S.F. / 0.091 ACRES (TRACT 'E' PER HOWARD BOUNDARY E� C \\ 1 \ '• SURVEY BY WSP; SEE "MAP .,\ \ \ '• REFERENCES FRBFC \ \ CMFS i \ �\ �. 9/16" IPF ASPHALT H ALT 0.55' NE OF CP \i 1 •1• PATH :\ \ It \, E 1 E 3 IN 1,\ '.1 v (� PIN 12� : 1 \' \ i\ \ 1 \'. --A ENE 21 \\ \\ CEO 1 SR 1600 & W R/W OF ATT) \\ \\ 0 CMF : S15'5 '46 "E, 36.54 1 \ O C) 1 \'� CMFI5,• S14'46' 2 "E, 169.71' CMF -OAK 21 1 \ 1 \ 1 a Lit \\ 1\ 1: 1 \ 1 1 1 1 -PINE 11 -04 1 \ � 1 I 1 1 PINE 12 PINE 14 1 1 1 it \: OAK i1 + +PIN 16 1 1: 1 1�. I. I -PINE 14 1 I 1 � - 1 1 1 1 1• I 1 1: 1 1'• 11 \II ?I I \ OAK 23 GENERAL NOTES 1. THE FOLLOWING INFORMATION WAS USED TO OBTAIN NC GRID NAD83(2011) /NAVD88 STATE PLANE COORDINATES (SPC) FOR THIS PROJECT: CLASS OF SURVEY: URBAN LAND SURVEYS (CLASS A) POSITIONAL ACCURACY: 0.02' GPS FIELD PROCEDURE: VRS DATES OF SURVEY: 10/24/13 AND 10/28/13 DATUM /EPOCH: NAD83(2011), EPOCH 2010.00 PUBLISHED /FIXED CONTROL USED: VRS, NCRD GEOID MODEL: NCGEOID12A COMBINED GRID FACTOR: 0.99990426 UNITS: US SURVEY FEET GRID /GROUND POINT: Y(N) 744,040.14 X(E) 2,022,781.40 2. ALL DISTANCES ARE HORIZONTAL GROUND DISTANCES IN U.S. SURVEY FEET UNLESS OTHERWISE NOTED. 3. AREAS SHOWN HEREON WERE COMPUTED USING THE COORDINATE COMPUTATION METHOD. 4. LINES NOT SURVEYED ARE SHOWN AS BROKEN LINES FROM INFORMATION REFERENCED ON THE FACE OF THIS PLAT. 5.[DELETED] 6. PROPERTY SUBJECT TO ALL EASEMENTS AND RESTRICTIONS OF RECORD. THIS PLAT IS A CORRECT REPRESENTATION OF THE LAND PLATTED AND HAS BEEN PREPARED IN CONFORMITY WITH NORTH CAROLINA STANDARDS, G.S. 47 -30, AND REQUIREMENTS OF LAW, BUT A NORTH CAROLINA LICENSED ATTORNEY -AT -LAW SHOULD BE CONSULTED REGARDING CORRECT OWNERSHIP, WIDTH, AND LOCATION OF EASEMENTS AND OTHER TITLE QUESTIONS REVEALED BY TITLE EXAMINATION. 7. SUBJECT PROPERTY IS NOT LOCATED WITHIN A FLOOD HAZARD AREA ACCORDING TO FLOOD INSURANCE RATE MAP 3720072400J, PANEL 0724 DATED MAY 2, 2006. 8. BUFFERS, PONDS, AND WETLAND FEATURES SHOWN ON THE HOWARD PROPERTY WERE DELINEATED BY S &EC ON 5/14/13, APPROVED BY WAKE COUNTY ON 7/16/13, AND CONFIRMED BY THE USACE ON 10/1/13. WETLAND FEATURES SHOWN ON THE EMERSON PROPERTY WERE DELINEATED BY S &EC ON 7/25/13, APPROVED BY WAKE COUNTY ON 8/20/13, AND APPROVED BY THE USACE ON 1011113. SEE THE S &EC AND WAKE COUNTY REPORTS FOR MORE INFORMATION ON THE VARIOUS FEATURES. 9. LOCATION OF UTILITIES, WHETHER PUBLIC OR PRIVATE, IS BASED UPON FIELD AND PHOTOGRAMMETRIC LOCATION OF VISIBLE APPURTENANCES IN CONJUNCTION WITH THE LOCATION OF UNDERGROUND UTILITY MARKING PAINT BY 811 AND IS APPROXIMATE ONLY. IT IS THE CONTRACTOR'S RESPONSIBILITY TO VERIFY LOCATION PRIOR TO COMMENCEMENT OF ANY CONSTRUCTION. WSP CANNOT ASSUME RESPONSIBILITY FOR MISIDENTIFICATION OR OMISSION OF UNDERGROUND UTILITIES. DUE TO OSHA REQUIREMENTS PERTAINING TO CONFINED SPACE ENTRY, PIPE SIZES, INVERT ELEVATIONS, ETC., WILL ONLY BE PROVIDED IF FIELD PERSONNEL ARE ABLE TO OBTAIN WITHOUT BREAKING THE PLANE OF THE TOP OF THE STRUCTURE. 10. A PORTION OF THE PLANIMETRIC AND TOPOGRAPHIC LOCATION ON THIS MAP IS BASED ON PHOTOGRAMMETRIC MAPPING OF IMAGERY COLLECTED ON DECEMBER 17, 2013. THE IMAGERY CAPTURED IS SUITABLE TO CREATE 1"=50' SCALE MAPPING AND CONTOURS AT AN INTERVAL OF 1'. THE MAPPING MEETS NATIONAL MAP ACCURACY STANDARDS FOR 1"=50' SCALE MAPPING. DATA PROVIDED WHERE CLEAR AND VISIBLE ON THE IMAGERY IS WITHIN 0.85' OF ITS TRUE POSITION. SOURCE OF TITLE HOWARD: DB 13188, PG. 1610 PIN: 0724 -23 -6305 (TRACTS A & B) PIN: 0724 -34 -1025 (TRACT E) EMERSON /WASHBURN: DB 12448, PG. 2709 PIN: 0724 -22 -1707 (LOT 1) PIN: 0724 -22 -4623 (LOT 2) PIN: 0724 -22 -0573 (LOT 3) PIN: 0724 -22 -0336 (LOT 6) PIN: 0724 -22 -3238 (LOT 7) PIN: 0724 -22 -2025 (LOT 7A) MAP REFERENCES BM 1971, PG. 112; BM 1978, PG. 467; BM 1979, PG. 676; BM 1987, PG. 1607; BM 1995, PG. 270; BM 1996, PG. 986; BM 1997, PG. 1003; BM 2002, PG. 1438; BM 2008, PG. 1689 MAP ENTITLED "BOUNDARY SURVEY, PROPERTY OF KAYE MANGUM HOWARD, DB 13188, PG. 1610" BY WSP DATED NOVEMBER 1, 2013, LAST REVISED AND SIGNED /SEALED BY THOMAS M. GRZEBIEN, P.L.S. #4695 ON NOVEMBER 18, 2013 MAP ENTITLED "BOUNDARY SURVEY, PROPERTY OF SCOTT A. WESTWOOD AND SANDRA B. EMERSON, WHITE OAK CHURCH ROAD, APEX" BY WSP DATED DECEMBER 30, 2013 AND SIGNED /SEALED BY THOMAS M. GRZEBIEN, P.L.S. #4695 ON JANUARY 4, 2014 OTHER REFERENCES AMERICAN TOBACCO TRAIL RIGHT -OF -WAY: DB 1940, PG. 83 MORRISVILLE PARKWAY RIGHT -OF -WAY: DB 2071, PG. 474; DB 2270, PG. 469 WHITE OAK CHURCH ROAD RIGHT -OF -WAY: DB 3315, PG. 457 AND 458 TRACTS A /B /E AND LOTS 1/2/3/6/7/7A WERE ANNEXED INTO THE TOWN OF CARY PER ORDINANCE # 13 -A -24 EASEMENTS OF RECORD HOWARD: 30' CP &L EASEMENTS (CENTERED ON APPURTENANCES): DB 1935, PG. 618; DB 2185, PG. 451 UNITED STATES OF AMERICA PERPETUAL AND ASSIGNABLE EASEMENT AND RIGHT -OF -WAY (SEE LEGEND): DB 1940, PG. 83 EMERSON /WASHBURN: 30' CP &L EASEMENTS (CENTERED ON APPURTENANCES): DB 1935, PG. 695; DB 1949, PG. 644; DB 3348, PG. 330 CP &L BLANKET EASEMENT: DS 1937, PG. 15 ZONING TOWN OF CARY CLASSIFICATION: R40CU (TRACTS A /B /E AND LOTS 1/2/3/6/7/7A PRELIMNARY MAP FOR REVIEW PURPOSES ONLY LEI RBFC • AST 1105 0 CO • O CMF ■ C EOI IPF • IRF • A RRSF • RBF • RBFC • -R/W- - - - - - - - - - - - - - - - - - --- 0 mmmmmmmmmm OAK 21+ ED 0 CA o —UE— —UE— —UE UFO FO FO GAS UM o UP • WV 9 WF01 o SEND 1/2" REBAR w/ CAP FOUND ABOVE GROUND STORAGE TANK (OIL) ADDRESS BUSH /SHRUB CLEANOUT COMPUTED POINT CONCRETE RIGHT -OF -WAY MONUMENT FOUND GUY ANCHOR END OF S.U.E. INFORMATION EXISTING EASEMENT (AS LABELED) IRON PIPE FOUND IRON ROD FOUND LIGHT POLE MAIL BOX PROPERTY LINE PROPERTY LINE (NOT SURVEYED) RAILROAD SPIKE FOUND REBAR FOUND REBAR w/ CAP FOUND RIGHT -OF -WAY (NOT SURVEYED) SATELLITE DISH SIGN STORM PIPE STORM PIPE (APPROXIMATE DIRECTION) TELEPHONE PEDESTAL TOWN OF CARY ETJ TREE (TYPE /DIAMETER) TREE FROM ELLIS FORESTRY REPORT TREE (CONIFEROUS) TREE (DECIDUOUS) TREE LINE UNDERGROUND CABLE BOX UNDERGROUND ELECTRIC UNDERGROUND FIBER OPTIC BOX UNDERGROUND FIBER OPTIC PAINT MARKS UNDERGROUND GAS PAINT MARKS UNDERGROUND UTILITY MARKER UNITED STATES OF AMERICA PERPETUAL AND ASSIGNABLE EASEMENT AND RIGHT -OF -WAY UTILITY POLE UTILITY LINE (OVERHEAD) WATER VALVE / BLOW OFF WETLAND FLAG i; o Z n1 < M wm m L� z 00 N E V) 0 Q U m Z GRAPHIC SCALE 60 0 30 60 120 ( IN FEET ) 1 inch = 60 ft. 14 —SP -049 HTE #: 15 -0029 APPROVED BY THE TOWN OF CARY DEVELOPMENT REVIEW COMMITTEE PLANNER Date U ,�mwsp 15401 Weston Parkway Suite 100 Cary, NC 27513 919.678.0035 www.wspgroup.com /usa PRELIMINARY NOT RELEASED FOR CONSTRUCTION NC LICENSE # F -0891 z U) U Z f1 0 V Q J 0 O z O Z O \` Q z Q U U U� G U Z OWE O V zQ U) wU U z W ry >- W< U N= L.L Z O � U z O REVISIONS PROJECT #:11370024.000 DATE: 5/20/14 1 DRAWN BY: JMS/TMG CHECKED BY: TMG TITLE EXISTING CONDITIONS SHEET 0.2 0 z i a a 0 O 0 D O 0 0 0 a L 3 0 a 0 N U / U U z z rn 3 0 0 0 .0 0 U 0 U / L 3 L U E 0 U a� 3 0 z N a O i 0 N 0 0 M i Y ° \ r P�' CHAPEL _ 2,552 SF GENERAL NOTES: 1. ALL CONSTRUCTION MOST BE PERFORMED IN ACCORDANCE WITH THE CURRENT TOWN OF CARY STANDARD SPECIFICATIONS AND DETAILS. 2. SEE THE TOWN OF CARY LAND DEVELOPMENT ORDINANCE FOR PORCHES, DECKS, GARAGES, ETC. 3. UTILITY AND PIPELINE EASEMENTS SHALL BE RECORDED AFTER CONSTRUCTION IS COMPLETED PRIOR TO ISSUANCE OF A CERTIFICATE OF OCCUPANCY (CO). 4. BOUNDARY INFORMATION IS BASED ON SURVEY BY WSP. 5. DESIGN BASED ON TOPOGRAPHIC SURVEY BY WSP. & CONTRACTOR SHALL VERIFY LOCATION OF ALL EXISTING UTILITIES PRIOR TO CONSTRUCTION. LOCATION OF EXISTING UTILITIES SHOWN ON PLANS IS BASED ON BEST AVAILABLE INFORMATION BUT CAN BE CONSIDERED ONLY AS APPROXIMATE. 7. ALL HANDICAP RAMPS SHALL BE CONSTRUCTED IN ACCORDANCE WITH CURRENT TOWN OF CARY STANDARD DETAILS. & ALL SPECIALTY STREET SIGNS AND POST SHALL BE SUBMITTED TO THE TOWN FOR REVIEW AND APPROVAL PRIOR TO INSTALLATION. 9. THE DEVELOPER WILL BE RESPONSIBLE FOR ALL INSTALLATION COST ASSOCIATED WITH STREET LIGHTING ALONG ALL PROPOSED STREETS, ADJACENT STREETS AND THOROUGHFARES AS REQUIRED PER TOWN OF CARY POLICY STATEMENT NO. 13. THE DEVELOPER SHALL ALSO CONTACT CAROLINA POWER AND LIGHT COMPANY IN ORDER TO DEVELOP A STREET LIGHTING PLAN FOR THE SITE /SUBDIVISION PLAN PRIOR TO CONSTRUCTION. 10. ADJACENT OPEN SPACE WILL BE RECORDED AS LOTS ARE RECORDED. OPEN SPACE SEPARATING TWO PARCELS WILL BE RECORDED APPROXIMATELY HALFWAY BETWEEN THE PHASES WITH THE ADJACENT PHASE. 11. STORMWATER DETENTION DEVICES VISIBLE FROM THE REAR YARD OF ANY ADJOINING DWELLING SHALL BE SCREENED FROM OFF -SITE VIEWS. EXCEPT WHERE DEVICE PLANTINGS ALSO SERVE AS BUFFER PLANTING MATERIALS. 12. THIS PROJECT IS REQUIRED TO MEET ALL OF THE REQUIREMENTS RELATIVE TO BEST MANAGEMENT PRACTICES AND ENGINEERED STORM WATER CONTROL STRUCTURES AS OUTLINED IN THE TOWN OF CARY LAND DEVELOPMENT ORDINANCE 13. TREES SHALL NOT BE PLANTED IN ANY TOWN OF CARY SANITARY SEWER EASEMENTS. 14. IF THERE WILL BE A TRASH COMPACTOR ON THE SITE A CONNECTION TO SANITARY SEWER & A COVERED DUMPSTER WILL BE REQUIRED. 15. IF ANY EXTERIOR WALLS ARE LOCATED WITHIN THREE FEET OF A PROPERTY LINE, THE FOLLOWING NOTE APPLIES: PER THE NORTH CAROLINA STATE BUILDING CODE SECTION R302.1 EXTERIOR WALLS: EXTERIOR WALLS WITH A FIRE SEPARATION DISTANCE LESS THAN THREE FEET SHALL HAVE NOT LESS THAN A ONE -HOUR FIRE - RESISTIVE RATING WITH EXPOSURE FROM BOTH SIDES. 16. ALL STRUCTURES WITHIN THE BOUNDARIES OF THE SITE ARE REQUIRED TO OBTAIN INDIVIDUAL PERMITS FROM THE TOWN OF CARY INSPECTIONS & PERMITS DEPARTMENT. THIS WOULD INCLUDE RETAINING WALLS AND FISHING PIER. / 17. ALL STREETS, DRIVES, PARKING AREAS, SIDEWALKS, ETC. NOT LOCATED WITHIN A PUBLIC R/W WILL BE CLEARLY IDENTIFIED AS PUBLIC VEHICLE ACCESS AREAS DEEDED TO THE OWNER, THE MAINTENANCE OF WHICH IS NOW AND FOREVERMORE THE RESPONSIBILITY OF SAID OWNER. THE t ° , ,_ . � . •._ : • � � DOCUMEN T S W I LL I NCLUDE A STATEMENT (COVENANT) TO TH E E FF EC T THAT "A LL S TR EE T S DRIVES PARKING AREAS A ND SIDEWALKS NOT LOCATED FRONT OF BLDG WITHIN THE PUBLIC R / W ARE PRIVATE PROPERTY ( SUBJECT TO PUBLIC VEHICLE ACCESS EASEMENTS THE MAINTENANCE OF WHICH IS THE SOLE ♦ :.... ; .•. .:. � � ° / / / ♦ ;r::.;' FOR ADDRESSING PURPOSES / i I RESPONSIBILITY OFTHE OWNER NOW AND IN PERPETUITY." THE TOWNOF CARY IS NOT RESPONSIBLE FOR ANY MAINTENANCE. 18 . R DEVELOPER IS RESPONSIBLE BLE FOR COORDINATING ATT CONNECTION APPROVAL J NCDO T, ETC WITH ALL APPROPRIATE JURISDICTIONS, COUNTY, 1 / / ♦♦ / kO ACCESSIBLE ROUTE .00 \ \ � �' � ♦ � ` / I IW ROADWAY IMPROVEMEN S PER 14 -SB -014 THE ESTA S AT a YATES POND SUBDIVISI IN PLANS. CONSTRUCT 'TO B / / gJF`` la ZONING CONDITIONS 13- REZ -29 R r COORDINATED WITH TIM( G OF SUBDIVISION PROJECT, E / ♦ �yQ�' I I Iz A. USES SHALL BE LIMITED TO RESIDENTIAL AND /OR RELIGIOUS ASSEMBLY USES. \ FRONTAGE IMPROVEMENT /� -I I Q B. RESIDENTIAL USE SHALL BE LIMITED TO A MAXIMUM OF 48 DETACHED DWELLINGS. `ALONG THE CHURCH PRO CT / ♦ k� / \ / I I J C. RELIGIOUS ASSEMBLY USE SHALL NOT EXCEED 20,000 SF. SHALL BE COMPLETED PRIG '�, / 1 / �� / L \ I Iml D. ANY RELIGIOUS ASSEMBLY ACCESSORY DAY CARE OR SCHOOL USE SHALL BE LIMITED TO NO MORE THAN 38 CHILDREN OR STUDENTS. 00 �`��'. C.O. OF THE CHURCH / < \\ \ I } LLJ el \ ` 20 TO UTILITY / \ EASEMENT \ 20' TOC UTILITY \ \ \ \ EASEMENT P / J \ \ \ \ / a ` ` C I ROUTE oo C25 .W AASHTO INTERSECTION SIGHT DISTANCE TRIANGLE SUMMARY Calculated - - - - -- ----------- - - - - -- '. Street Name (Approaching Street Stop Condition ) Design Speed of Through Street Grade of Approach Left Turn Time Gap sec. --------- P_E_DESTRIAN CONNECTION TO T_H_E __- -- Left Turn Sight Distance ft. Right Turn Sight Distance ft. \ ROAD R001 — ___ - ---- AMERICAN TO.BACC-a TRAIL I ' 6.50 276 239 MORRISVILLE PKWY ROAD R001 50 THIS PRIVATE SPUR TO 7.50 6.50 � 478 — BE CONSTRUCTED BY PUBLIC UTILITIES: - -- — � I THE RESIDENTIAL 0 R� __ --' ,_ - -- -� 124 I II I '..O FORMERLY DEVELOPER OF 14 -SB -014 OR RECLAIMED WATER TAPS: 0 ________ ____ __ ____ AMER\CAo P�c ` MMUNIT COPPERL� ; : CbMMUNITY ASSOCIATION, INC. CHURCH IF EASEMENT r -__ MON OPEN SPACE) 14128, PG. 620 FROM COPPERLEAF HOA CAN BE OBTAINED MINIMUM PARKING REQUIRED: 419 CHURCH SEATS / 3 = 140 SEATS PARKING SPACES PROVIDED: 158 (7 ACCESSIBLE) BIKE RACKS REQUIRED: 2 BIKE RACKS PROVIDED: 2 HANDICAPPED PARKING REQUIRED: Mown I PIN: 0724 -33 -1006 NOW OR FORMERLY ROADWAY SETBACKS: 50' Y\ZONING: PDDMajor COUNTY OF WAKE and TOWN OF CARY FIRE LANE (LF): 456 ATT BUFFER \ DB 9561, PG. 1709 CARY ZONING: 9R/R ° \ r P�' CHAPEL _ 2,552 SF GENERAL NOTES: 1. ALL CONSTRUCTION MOST BE PERFORMED IN ACCORDANCE WITH THE CURRENT TOWN OF CARY STANDARD SPECIFICATIONS AND DETAILS. 2. SEE THE TOWN OF CARY LAND DEVELOPMENT ORDINANCE FOR PORCHES, DECKS, GARAGES, ETC. 3. UTILITY AND PIPELINE EASEMENTS SHALL BE RECORDED AFTER CONSTRUCTION IS COMPLETED PRIOR TO ISSUANCE OF A CERTIFICATE OF OCCUPANCY (CO). 4. BOUNDARY INFORMATION IS BASED ON SURVEY BY WSP. 5. DESIGN BASED ON TOPOGRAPHIC SURVEY BY WSP. & CONTRACTOR SHALL VERIFY LOCATION OF ALL EXISTING UTILITIES PRIOR TO CONSTRUCTION. LOCATION OF EXISTING UTILITIES SHOWN ON PLANS IS BASED ON BEST AVAILABLE INFORMATION BUT CAN BE CONSIDERED ONLY AS APPROXIMATE. 7. ALL HANDICAP RAMPS SHALL BE CONSTRUCTED IN ACCORDANCE WITH CURRENT TOWN OF CARY STANDARD DETAILS. & ALL SPECIALTY STREET SIGNS AND POST SHALL BE SUBMITTED TO THE TOWN FOR REVIEW AND APPROVAL PRIOR TO INSTALLATION. 9. THE DEVELOPER WILL BE RESPONSIBLE FOR ALL INSTALLATION COST ASSOCIATED WITH STREET LIGHTING ALONG ALL PROPOSED STREETS, ADJACENT STREETS AND THOROUGHFARES AS REQUIRED PER TOWN OF CARY POLICY STATEMENT NO. 13. THE DEVELOPER SHALL ALSO CONTACT CAROLINA POWER AND LIGHT COMPANY IN ORDER TO DEVELOP A STREET LIGHTING PLAN FOR THE SITE /SUBDIVISION PLAN PRIOR TO CONSTRUCTION. 10. ADJACENT OPEN SPACE WILL BE RECORDED AS LOTS ARE RECORDED. OPEN SPACE SEPARATING TWO PARCELS WILL BE RECORDED APPROXIMATELY HALFWAY BETWEEN THE PHASES WITH THE ADJACENT PHASE. 11. STORMWATER DETENTION DEVICES VISIBLE FROM THE REAR YARD OF ANY ADJOINING DWELLING SHALL BE SCREENED FROM OFF -SITE VIEWS. EXCEPT WHERE DEVICE PLANTINGS ALSO SERVE AS BUFFER PLANTING MATERIALS. 12. THIS PROJECT IS REQUIRED TO MEET ALL OF THE REQUIREMENTS RELATIVE TO BEST MANAGEMENT PRACTICES AND ENGINEERED STORM WATER CONTROL STRUCTURES AS OUTLINED IN THE TOWN OF CARY LAND DEVELOPMENT ORDINANCE 13. TREES SHALL NOT BE PLANTED IN ANY TOWN OF CARY SANITARY SEWER EASEMENTS. 14. IF THERE WILL BE A TRASH COMPACTOR ON THE SITE A CONNECTION TO SANITARY SEWER & A COVERED DUMPSTER WILL BE REQUIRED. 15. IF ANY EXTERIOR WALLS ARE LOCATED WITHIN THREE FEET OF A PROPERTY LINE, THE FOLLOWING NOTE APPLIES: PER THE NORTH CAROLINA STATE BUILDING CODE SECTION R302.1 EXTERIOR WALLS: EXTERIOR WALLS WITH A FIRE SEPARATION DISTANCE LESS THAN THREE FEET SHALL HAVE NOT LESS THAN A ONE -HOUR FIRE - RESISTIVE RATING WITH EXPOSURE FROM BOTH SIDES. 16. ALL STRUCTURES WITHIN THE BOUNDARIES OF THE SITE ARE REQUIRED TO OBTAIN INDIVIDUAL PERMITS FROM THE TOWN OF CARY INSPECTIONS & PERMITS DEPARTMENT. THIS WOULD INCLUDE RETAINING WALLS AND FISHING PIER. / 17. ALL STREETS, DRIVES, PARKING AREAS, SIDEWALKS, ETC. NOT LOCATED WITHIN A PUBLIC R/W WILL BE CLEARLY IDENTIFIED AS PUBLIC VEHICLE ACCESS AREAS DEEDED TO THE OWNER, THE MAINTENANCE OF WHICH IS NOW AND FOREVERMORE THE RESPONSIBILITY OF SAID OWNER. THE t ° , ,_ . � . •._ : • � � DOCUMEN T S W I LL I NCLUDE A STATEMENT (COVENANT) TO TH E E FF EC T THAT "A LL S TR EE T S DRIVES PARKING AREAS A ND SIDEWALKS NOT LOCATED FRONT OF BLDG WITHIN THE PUBLIC R / W ARE PRIVATE PROPERTY ( SUBJECT TO PUBLIC VEHICLE ACCESS EASEMENTS THE MAINTENANCE OF WHICH IS THE SOLE ♦ :.... ; .•. .:. � � ° / / / ♦ ;r::.;' FOR ADDRESSING PURPOSES / i I RESPONSIBILITY OFTHE OWNER NOW AND IN PERPETUITY." THE TOWNOF CARY IS NOT RESPONSIBLE FOR ANY MAINTENANCE. 18 . R DEVELOPER IS RESPONSIBLE BLE FOR COORDINATING ATT CONNECTION APPROVAL J NCDO T, ETC WITH ALL APPROPRIATE JURISDICTIONS, COUNTY, 1 / / ♦♦ / kO ACCESSIBLE ROUTE .00 \ \ � �' � ♦ � ` / I IW ROADWAY IMPROVEMEN S PER 14 -SB -014 THE ESTA S AT a YATES POND SUBDIVISI IN PLANS. CONSTRUCT 'TO B / / gJF`` la ZONING CONDITIONS 13- REZ -29 R r COORDINATED WITH TIM( G OF SUBDIVISION PROJECT, E / ♦ �yQ�' I I Iz A. USES SHALL BE LIMITED TO RESIDENTIAL AND /OR RELIGIOUS ASSEMBLY USES. \ FRONTAGE IMPROVEMENT /� -I I Q B. RESIDENTIAL USE SHALL BE LIMITED TO A MAXIMUM OF 48 DETACHED DWELLINGS. `ALONG THE CHURCH PRO CT / ♦ k� / \ / I I J C. RELIGIOUS ASSEMBLY USE SHALL NOT EXCEED 20,000 SF. SHALL BE COMPLETED PRIG '�, / 1 / �� / L \ I Iml D. ANY RELIGIOUS ASSEMBLY ACCESSORY DAY CARE OR SCHOOL USE SHALL BE LIMITED TO NO MORE THAN 38 CHILDREN OR STUDENTS. 00 �`��'. C.O. OF THE CHURCH / < \\ \ I } LLJ el \ ` 20 TO UTILITY / \ EASEMENT \ 20' TOC UTILITY \ \ \ \ EASEMENT P / J \ \ \ \ / a ` ` C I ROUTE oo C25 .W LAYGROUN 1.01( \ ,\ \ °o ACCESSIBLE ROUTE / 'o, i \ e \ 3' TOC COMM / / EASEMENT / \ ♦ \ / OUTDOOR BAPTISTRY / / /\ �O\ \ �` �` �` i/ / / BMP A tz- 000l oo, IMPROVEMENTS `� / `,` ` \ I \ �► 1 :1 PROPOSED 6,042 FURCH I \ �, \ / , �\ PER 1 4 — S B — 01 4 lo, 1' \ \ BMP 1 ;f , 20' PRIVATE STORM ` SEMENT FRONT OF BLDG ` I FOR ADDRESSING PURPOSE NOW OR FORMERLY �\ �� + ILL, J / / ♦ k 5� v %' / / / \ \ \ \ CL I / l ^ / KAYE MANGUM HOWARD I I ,IQ BUFFER ENCROACMENT AREA DB 13188, PG. 1610 `� I I IN I DUE TO INFRASTRUCTURE PIN: 0724 -23 -6305 I- w WAKE ZONING:R -40W ` I f TO BE REPLANTED TO OPAQUE \ 1 BUFFER STDS \ \ \ \ \ I I 10,208 SF N STORMWATER ACCESS AND rn & l o MAINTENANCE EASEMENT ♦ \ ,� \ \ SIDEWALK ESMT 2' OFF I `;I BACK OF SIDEWALK \ \ I ' % i I II I I 5' SIDEWALK TO ♦ ♦ / 1 I I I EXISTING BUILDING ON SITE I I BUFFER MAKE UP AREA ♦ - I10,530 SF ♦ \ ` 1 I III I + I II \ I I 1 � • TRACT A NOW OR FORMERLY ' ' • :'- • _ _ I I H KAYE MANGUM HOWARD w Ln ULTIMATE 30' PIN30724 23 -6305 N w . I I COMBINED 50' TOC UTILITY Q L — — — — - -� STREETYARD AROUND EASEMENT, ACCESS EASEMENT, w SPEED TIE TO EOP STOP THE EXISTING HOUSE TO 1,022,454 S.F./ 23.472 ACRES AND STORM DRAINAGE EASEMENT o LIMIT PER 14 -SB -014 ; I I I I BE PLANTED WHEN THE (PER HOWARD BOUNDARY SURVEY BY WSP) Ln 2 5 T — I I I I STRUCTURE IS REMOVED ° I + I T EXISING BRICK I OUT OF THE YARD AND I C, I BUILDING TO REMAIN CAN BE VEGETATED N I + + + I I UNTIL PHASE 2 OF ROADWAY IMPROVEMENTS CHURCH CAMPUS N I II I I+ SIGHT DIST. O REQUIRES REMOVAL I PER 14 -SB -014 THE ESMT o I I I I ESTATES AT YATES POND T 0 II DI PLANS. 010 RR VI PKWY CONSTRUCTIONOBE O - I` Exaoo COORDINATED WITH �' �:•I \ \ I I I TIMING Ur SUBDIVISION PROJECT SIDEWALK ESMT 2' OFF I I I I \ y } 3' TOC COMMON UTILITY BACK OF SIDEWALK ' I — I - - — — — __ �'-- — TREETS — - - -__ — — D _ — — — — 30 _ S _ CAP �•. ,...,. IT .........:: _ -- - 0 +00 I I 1 1 +00 it 12 +00 13 +00 � 14+ i I ► I —+ 00 I 15 +00 16 +00 - i I I ► 18 +00 A - _ 19 +00 7—At -a-- No. Revision Date B Designer TLM AASHTO INTERSECTION SIGHT DISTANCE TRIANGLE SUMMARY Calculated Calculated Street Name (Through Traffic Street Name (Approaching Street Stop Condition ) Design Speed of Through Street Grade of Approach Left Turn Time Gap sec. Right Turn Time Gap sec. Left Turn Sight Distance ft. Right Turn Sight Distance ft. ROAD R002 ROAD R001 25 -1.78 7.50 6.50 276 239 MORRISVILLE PKWY ROAD R001 50 1.52 7.50 6.50 551 478 0 PUBLIC UTILITIES: 8'' WATER LINE (LF): 1805 RECLAIMED WATER LINES (LF): LAYGROUN 1.01( \ ,\ \ °o ACCESSIBLE ROUTE / 'o, i \ e \ 3' TOC COMM / / EASEMENT / \ ♦ \ / OUTDOOR BAPTISTRY / / /\ �O\ \ �` �` �` i/ / / BMP A tz- 000l oo, IMPROVEMENTS `� / `,` ` \ I \ �► 1 :1 PROPOSED 6,042 FURCH I \ �, \ / , �\ PER 1 4 — S B — 01 4 lo, 1' \ \ BMP 1 ;f , 20' PRIVATE STORM ` SEMENT FRONT OF BLDG ` I FOR ADDRESSING PURPOSE NOW OR FORMERLY �\ �� + ILL, J / / ♦ k 5� v %' / / / \ \ \ \ CL I / l ^ / KAYE MANGUM HOWARD I I ,IQ BUFFER ENCROACMENT AREA DB 13188, PG. 1610 `� I I IN I DUE TO INFRASTRUCTURE PIN: 0724 -23 -6305 I- w WAKE ZONING:R -40W ` I f TO BE REPLANTED TO OPAQUE \ 1 BUFFER STDS \ \ \ \ \ I I 10,208 SF N STORMWATER ACCESS AND rn & l o MAINTENANCE EASEMENT ♦ \ ,� \ \ SIDEWALK ESMT 2' OFF I `;I BACK OF SIDEWALK \ \ I ' % i I II I I 5' SIDEWALK TO ♦ ♦ / 1 I I I EXISTING BUILDING ON SITE I I BUFFER MAKE UP AREA ♦ - I10,530 SF ♦ \ ` 1 I III I + I II \ I I 1 � • TRACT A NOW OR FORMERLY ' ' • :'- • _ _ I I H KAYE MANGUM HOWARD w Ln ULTIMATE 30' PIN30724 23 -6305 N w . I I COMBINED 50' TOC UTILITY Q L — — — — - -� STREETYARD AROUND EASEMENT, ACCESS EASEMENT, w SPEED TIE TO EOP STOP THE EXISTING HOUSE TO 1,022,454 S.F./ 23.472 ACRES AND STORM DRAINAGE EASEMENT o LIMIT PER 14 -SB -014 ; I I I I BE PLANTED WHEN THE (PER HOWARD BOUNDARY SURVEY BY WSP) Ln 2 5 T — I I I I STRUCTURE IS REMOVED ° I + I T EXISING BRICK I OUT OF THE YARD AND I C, I BUILDING TO REMAIN CAN BE VEGETATED N I + + + I I UNTIL PHASE 2 OF ROADWAY IMPROVEMENTS CHURCH CAMPUS N I II I I+ SIGHT DIST. O REQUIRES REMOVAL I PER 14 -SB -014 THE ESMT o I I I I ESTATES AT YATES POND T 0 II DI PLANS. 010 RR VI PKWY CONSTRUCTIONOBE O - I` Exaoo COORDINATED WITH �' �:•I \ \ I I I TIMING Ur SUBDIVISION PROJECT SIDEWALK ESMT 2' OFF I I I I \ y } 3' TOC COMMON UTILITY BACK OF SIDEWALK ' I — I - - — — — __ �'-- — TREETS — - - -__ — — D _ — — — — 30 _ S _ CAP �•. ,...,. IT .........:: _ -- - 0 +00 I I 1 1 +00 it 12 +00 13 +00 � 14+ i I ► I —+ 00 I 15 +00 16 +00 - i I I ► 18 +00 A - _ 19 +00 7—At -a-- No. Revision Date B Designer TLM Scale 1 " =60' Drawn By Date BCP /TLM 06/26/2014 Checked By Job No. ET 02130427.00 Northwest Community Church Town of Cary Wake County North Carolina SITE PLAN 22 +0 PROPERTY OWNER: NORTHWEST COMMUNITY CHURCH OF CARY, INC. 10109 MORRISVILLE PKWY CARY, NC 27519 PIN: 0724230269 (PORTION OF) REAL ID: 0421237 (PORTION OF) DB 15709 PG 2202 ZONING: R40W OVERLAY DISTRICT: VERY LOW CONSERVATION RESIDENTIAL PROJECT AREA: 20.07 ACRES SITE DATA BUILDING SUMMARY: CLASSIFICATION CHURCH FLOOR AREA (SF) 16,042 CHAPEL FLOOR AREA (SF): 2,552 EXISTING HOUSE TO REMAIN (SF) 1,400 TOTAL SF: 19,994 25 25 PROPOSED USE: RELIGIOUS ASSEMBLY IMPERVIOUS SUMMARY: TOTAL IMPERVIOUS AREA (AC): 3.72 TOTAL IMPERVIOUS PERCENTAGE: 19% DISTURBANCE SUMMARY: TOTAL DISTURBED AREA (AC): 11.4 TOTAL WETAND IMPACT (AC): 0 PUBLIC UTILITIES: 8'' WATER LINE (LF): 1805 RECLAIMED WATER LINES (LF): 0 SEWER LINES (LF): 124 WATER TAPS: 2 RECLAIMED WATER TAPS: 0 SEWER TAPS: 2 PROJECTED SEWER FLOW (GPD): 1,800 GPD 20,000 sf x 0.09 gpd per sf = 1,800 gpd PARKING COUNT: 1 SPACE PER 3 SEATS PROVIDED MINIMUM PARKING REQUIRED: 419 CHURCH SEATS / 3 = 140 SEATS PARKING SPACES PROVIDED: 158 (7 ACCESSIBLE) BIKE RACKS REQUIRED: 2 BIKE RACKS PROVIDED: 2 HANDICAPPED PARKING REQUIRED: 6 SPACES HANDICAPPED PARKING PROPOSED: 7 SPACES ROADWAY SETBACKS: 30' PRIVATE ROADWAY (LF): 1616 FIRE LANE (LF): 456 ROAD CLASSIFCATION TABLE ROADWAY CLASSIFICATION POSTED SPEED DESIGN SPEED LENGTHS: (MPH) (MPH) (LF) R001 MAJOR LOCAL (PRIVATE) 25 25 1616 GRAPHIC SCALE 60 0 30 60 120 f a ° � ,``NI CAR ° °° KNOW WHAT'S BELOW. NORT H CALL BEFORE YOU DIG. `00`e �`�,,�- pFESS /p by -ee P Cary ' c� ( Y Project Number 14 -SP -049 Cary HTE Number 15 -0029 NOT APER VE021 6CO SIRUCTION Approved by the Town of Cary Development Review Committee eee' C VCIO ,```a RD P0% Planner Dote /111111111` WITHERS RAVEN EL ENGINEERS I PLANNERS I SURVEYORS 111 MacKenan Drive Cary, North Carolina 27511 tel: 919- 469 -3340 www.withersravenel.com License No. C -0832 Sheet No. C2.0 0 w z a M O V N 0 a 0 0 0 ID 3 3 a w z 0 0 z a 0 a 0 a U U z z i 0 / ERICA PUgUC PRIVATE TRAIL SURFACE TO T� IAI�F/ttiSFi ��H \ r� AM [;100 EXISTING A�T TRAIL SUR E APPROX. EL 3;71.32 I I� r� ;BRA 50' A�T BUFFER Lu / Yd ? t0 Z ? z Z/ z / Z z Z M? N RIVATE TRAIL SURFIC TI�INFLUSO WITH W Z Z- \ �� 365.33- i=3F,5 7n I "oo \ \ 1 \ / / \ �\ l000, 1000' LU_ \ \ \ =mom \ \ \ \\\ \ \ \ \ 1 \ �z-, y \I 1X& \ \r \ \ \I� 1 \19 11II \ 1 1 1I �1III� 1 I �o \ 1 Illio NOW OR FORMERLY I I I KAYE MANGUM HOWARD N II I IN DB 13188, PG. 1610 z I III PIN: 0724 -23 -6305 WAKE ZONING: R-40W w z No. Revision Date B a`'' III 0 ��I11 y„o0� Ill��u Ym� III Q_ N UJ Flo UJ 4U 1 N W _:�: hl II LNpl II ° II o II N II I III IIV II � 11 cv _ Ill" h � I \I II I I I I II I III N I I I IINt 1, l ,Y+001 III I � I / Designer TLM Scale 1 " =60' Drawn By Date BCP /TLM 06/26/2014 Checked By Job No. ET 02130427.00 Northwest Community Church Town of Cary Wake Coun North Carolina PRIVATE TRAIL SURFAC� -TO TIE IN FLUSH WITH ,1 EXISTING ATT TRAIL SURFACE, APPROX EL 365.1' 4- /- 16R-FOf2MERLY / - - - i / ' IMMUNITY ASS6CIATION, INC. 109OPE"PACE)/ 14128, PG. 620 I 1: 0724- 334006- - / \ - - - NOW OR FORMERLY ZONING: PDDMajor COUNTY OF WAKE and TOWN OF CARY DB 9561, PG. 1709 I / - PIN: 0724 -21 -9914 v CARY ZONING: R/R NORTH GRADING & EROSION CONTROL NOTES 1. CONTRACTOR SHALL CONSTRUCT DIVERSION DITCHES AS NECESSARY TO ENSURE ALL SEDIMENT IS DIRECTED INTO EROSION CONTROL MEASURES. 2. ALL CATCH BASINS SHALL BE PROTECTED PER TOC ST. 04000.14 UNLESS NOTED OTHERWISE. 3. CONTRACTOR SHALL VERIFY LOCATION OF ALL EXISTING UTILITIES PRIOR TO CONSTRUCTION. LOCATION OF EXISTING UTILITIES SHOWN ON PLANS IS BASED ON BEST AVAILABLE INFORMATION BUT CAN BE CONSIDERED ONLY AS APPROXIMATE. 4. CONTRACTOR SHALL ENSURE GRADING OPERATION IS CONDUCTED IN A MANNER THAT DOES NOT ALLOW ANY SEDIMENT INTO CREEKS. 5. ALL STORM DRAINAGE PIPE SHALL BE PROTECTED DURING CONSTRUCTION IN ACCORDANCE WITH TOC STD. DETAIL 04000.12. 6. CONTRACTOR SHALL PROVIDE RIP RAP LINED TAIL DITCHES AT THE STORM DRAINAGE PIPE DISCHARGE POINTS AS REQUIRED TO ENSURE POSITIVE DRAINAGE. 7. SEDIMENT BASINS SHALL BE KEPT OUT OF WETLAND AREAS. 8. A PRE - CONSTRUCTION MEETING MAY BE REQUIRED FOR THIS CONSTRUCTION. 9. ANY TOPSOIL THAT IS WASTED OFFSET SHALL BE PERMITTED OR PLACED IN FILL AREAS AS SHOWN ON THE PLANS. 10. TREE PROTECTION FENCING SHALL BE INSTALLED AND INSPECTED PRIOR TO ISSUANCE OF A GRADING PERMIT. 11. ALL CATCH BASIN HOODS SHALL BE STAMPED "DRAINS TO RIVER" WITH 3/4" HIGH LETTERING. 12. ALL STREETS ADJACENT TO THE PROJECT SHALL BE KEPT CLEAN AT ALL TIMES OR A WASH STATION WILL BE REQUIRED. 13. THE PROJECT WILL MEET ALL REQUIREMENTS RELATIVE TO BEST MANAGEMENT PRACTICES AND ENGINEERED STORMWATER CONTROL STRUCTURES AS OUTLINED IN THE TOWN OF CARY LAND DEVELOPMENT ORDINANCE. 14. RISER STRUCTURES MUST BE ON SITE PRIOR TO ISSUANCE OF A GRADING PERMIT. 15. A BUILDING PERMIT SHALL BE ISSUED FOR EACH LOT THAT IS CLEARED INDIVIDUALLY. IF MULTIPLE LOTS ARE CLEARED SIMULTANEOUSLY AND THE COMBINED DENUDED AREA IS OVER 12,000 SO. FT. AN EROSION CONTROL PLAN & A BUILDING PERMIT FOR EACH LOT TO BE CLEARED WILL HAVE TO BE SUBMITTED BEFORE THIS CLEARING BEGINS UNLESS INCLUDED AS PART OF THESE PLANS. 16. ALL REQUIREMENTS OF THE NPDES PERMITS SHALL BE MET. 17. A GRADING PERMIT WILL NOT BE ISSUED UNTIL THE TOWN OF CARY HAS RECEIVED NOTIFICATION FROM THE ECOSYSTEM ENHANCEMENT PROGRAM OR AN APPROVED NUTRIENT OFFSET BANK THAT A RECEIPT HAS BEEN ISSUED TO THE DEVELOPER AND THE LOCAL GOVERNMENT STATING THE NITROGEN BUY DOWN HAS BEEN COMPLETED. 18. ALL LEVEL SPREADERS ON THE PROJECT MUST BE LOCATED ON COMMON OPEN SPACE, HAVE AN ACCESS AND MAINTENANCE EASEMENT LOCATED AROUND THEM AND INCLUDE AN OPERATIONS AND MAINTENANCE AGREEMENT. Peak Attenuation Summa METHOD OF WATERSHED PROTECTION: 1V c THIS PHASE MEETS THE TOWN OF CARY RESERVOIR WATERSHED PROTECTION ORDINANCE (JORDAN LAKE WATERSHED) AS A HIGH DENSITY USE WITH THE PROJECT IMPERVIOUS PERCENTAGE LESS THAN 70 %. BMP'S ARE PROPOSED TO MEET WATERSHED REQUIREMENTS. -BMF' ---- i THE PROPOSED BMP'S CONSIST OF A WET DETENTION BASIN. THIS PROJECT MEETS ALL OF THE REQUIREMENTS RELATIVE TO BEST MANAGEMENT PRACTICES AND ENGINEERED STORMWATER CONTROL STRUCTURES AS OUTLINED IN THE TOWN OF CARY LAND DEVELOPMENT ORDINANCE, CHAPTER 4, PART 4.6. \ / I GRADING PLAN BMP DESIGN NOTES: THE BMP SHOWN ON THIS PLAN IS DESIGNED TO THE TOWN STANDARDS OF 2014 IN EFFECT AT THE TIME OF THIS PLAN APPROVAL. THE BMP IS DESIGNED FOR 37% MAXIMUM IMPERVIOUS (FOR FUTURE SITE EXPANSION), THE CURRENT PLAN HAS 18% IMPERVIOUS. GRAPHIC SCALE 60 0 30 60 120 r ESSIp Ll y P Dr NL NOT APER VE0216( 6C0 31RUCTION FHGINE�� R D S P �.�. Cary Project Number 14 -SP -049 Cary HTE Number 15 -0029 Approved by the Town of Cary Development Review Committee Planner WITHERS & RAVEN EL ENGINEERS I PLANNERS I SURVEYORS 111 MacKenan Drive Cary, North Carolina 27511 tel: 919 - 469 -3340 www.withersravenel.com License No. C -0832 Date Sheet No. C4.0 Pre Development Post Development Net Change Net Change Peak Flow Peak Flow w /BMP (cfs) ( %) Storm Event (cfs) WS) 1 -Year 35.91 17.45 -18.46 -51% 2 -Year 52.36 36.24 -16.12 -31% 5 -Year 71.30 64.62 -6.68 -9% 10 -Year 86.36 84.33 -2.03 -2% loo -Year 125.04 1 119.24 -5.8 -5% METHOD OF WATERSHED PROTECTION: 1V c THIS PHASE MEETS THE TOWN OF CARY RESERVOIR WATERSHED PROTECTION ORDINANCE (JORDAN LAKE WATERSHED) AS A HIGH DENSITY USE WITH THE PROJECT IMPERVIOUS PERCENTAGE LESS THAN 70 %. BMP'S ARE PROPOSED TO MEET WATERSHED REQUIREMENTS. -BMF' ---- i THE PROPOSED BMP'S CONSIST OF A WET DETENTION BASIN. THIS PROJECT MEETS ALL OF THE REQUIREMENTS RELATIVE TO BEST MANAGEMENT PRACTICES AND ENGINEERED STORMWATER CONTROL STRUCTURES AS OUTLINED IN THE TOWN OF CARY LAND DEVELOPMENT ORDINANCE, CHAPTER 4, PART 4.6. \ / I GRADING PLAN BMP DESIGN NOTES: THE BMP SHOWN ON THIS PLAN IS DESIGNED TO THE TOWN STANDARDS OF 2014 IN EFFECT AT THE TIME OF THIS PLAN APPROVAL. THE BMP IS DESIGNED FOR 37% MAXIMUM IMPERVIOUS (FOR FUTURE SITE EXPANSION), THE CURRENT PLAN HAS 18% IMPERVIOUS. GRAPHIC SCALE 60 0 30 60 120 r ESSIp Ll y P Dr NL NOT APER VE0216( 6C0 31RUCTION FHGINE�� R D S P �.�. Cary Project Number 14 -SP -049 Cary HTE Number 15 -0029 Approved by the Town of Cary Development Review Committee Planner WITHERS & RAVEN EL ENGINEERS I PLANNERS I SURVEYORS 111 MacKenan Drive Cary, North Carolina 27511 tel: 919 - 469 -3340 www.withersravenel.com License No. C -0832 Date Sheet No. C4.0 ° z a M N a 0 0 0 0 0 0 L i i a J a w cc a z a 0 z z a C) z 0 a 0 0 v / U U z z i 3 0 0 c 0 u 2 c 0 U ° a U / L 3 L U E E U L 0 z N a O i 0 N a 0 M i Y ___ I?, T 0g ACC0 x_ a a F_ / / �0 / A No. Revision Date B Designer TLM Scale AS NOTED F M Date \ = °W 06/26/2014 z Job No. �. o y ` o \ 10 \ c0 1+ N 1 1 1 1 1 I I I 0 NOW OR FORMERLY to I + KAYE MANGUM HOWARD N N DB 13188, PG. 1610 Z w I PIN: 0724 -23 -6305 w U Z WAKE ZONING: R-40W w z I 0 I of d 0 qt 0 �-°ol m Q_ o I D! LJ 4 W J.- = W O _N J I W Z M N IN LNOIa 0! ►I 0 + I° N I I I I I I I I IO I O I IN N I I I I I I I I I Io I I o I Nt I a I j0 +001 0 I I I I I II I I' IR �z No. Revision Date B Designer TLM Scale AS NOTED Drawn By Date BCP /TLM 06/26/2014 Checked By Job No. ET 02130427.00 – I-.. — — — — — — Northwest Community Church Town of Cary Wake Coun North Carolina ` PRIVATE TRAIL SURFACE TO TIE IN FLUSH WITH EXISTING ATT TRAIL SURFACE, APPROX EL 365.1' OR FORMERLY I OMUNITY ASSOCIATION, INC. I ON OPEN SPACE) 14128, PG. 620 I -- - -R,4W 0724 -33 -1006 NOW OR FORMERLY TONING: PDDMajor I COUNTY OF WAKE and TOWN OF CARY \ DB 9561, PG. 1709 \ I PIN: 0724 -21 -9914 CARY ZONING: R/R DRAINAGE PLAN , ..� \ O2 \ i � I I � � a dl _ cF GRADING & EROSION CONTROL NOTES 1. CONTRACTOR SHALL CONSTRUCT DIVERSION DITCHES AS NECESSARY TO ENSURE ALL SEDIMENT IS DIRECTED INTO EROSION CONTROL MEASURES. 2. ALL CATCH BASINS SHALL BE PROTECTED PER TOC ST. 04000.14 UNLESS NOTED OTHERWISE. 3. CONTRACTOR SHALL VERIFY LOCATION OF ALL EXISTING UTILITIES PRIOR TO CONSTRUCTION. LOCATION OF EXISTING UTILITIES SHOWN ON PLANS IS BASED ON BEST AVAILABLE INFORMATION BUT CAN BE CONSIDERED ONLY AS APPROXIMATE. 4. CONTRACTOR SHALL ENSURE GRADING OPERATION IS CONDUCTED IN A MANNER THAT DOES NOT ALLOW ANY SEDIMENT INTO CREEKS. 5. ALL STORM DRAINAGE PIPE SHALL BE PROTECTED DURING CONSTRUCTION IN ACCORDANCE WITH TOC STD. DETAIL 04000.12. 6. CONTRACTOR SHALL PROVIDE RIP RAP LINED TAIL DITCHES AT THE STORM DRAINAGE PIPE DISCHARGE POINTS AS REQUIRED TO ENSURE POSITIVE DRAINAGE. 7. SEDIMENT BASINS SHALL BE KEPT OUT OF WETLAND AREAS. 8. A PRE - CONSTRUCTION MEETING MAY BE REQUIRED FOR THIS CONSTRUCTION. 9. ANY TOPSOIL THAT IS WASTED OFFSET SHALL BE PERMITTED OR PLACED IN FILL AREAS AS SHOWN ON THE PLANS. 10. TREE PROTECTION FENCING SHALL BE INSTALLED AND INSPECTED PRIOR TO ISSUANCE OF A GRADING PERMIT. 11. ALL CATCH BASIN HOODS SHALL BE STAMPED "DRAINS TO RIVER" WITH 3/4" HIGH LETTERING. 12. ALL STREETS ADJACENT TO THE PROJECT SHALL BE KEPT CLEAN AT ALL TIMES OR A WASH STATION WILL BE REQUIRED. 13. THE PROJECT WILL MEET ALL REQUIREMENTS RELATIVE TO BEST MANAGEMENT PRACTICES AND ENGINEERED STORMWATER CONTROL STRUCTURES AS OUTLINED IN THE TOWN OF CARY LAND DEVELOPMENT ORDINANCE. 14. RISER STRUCTURES MUST BE ON SITE PRIOR TO ISSUANCE OF A GRADING PERMIT. 15. A BUILDING PERMIT SHALL BE ISSUED FOR EACH LOT THAT IS CLEARED INDIVIDUALLY. IF MULTIPLE LOTS ARE CLEARED SIMULTANEOUSLY AND THE COMBINED DENUDED AREA IS OVER 12,000 SO. FT. AN EROSION CONTROL PLAN & A BUILDING PERMIT FOR EACH LOT TO BE CLEARED WILL HAVE TO BE SUBMITTED BEFORE THIS CLEARING BEGINS UNLESS INCLUDED AS PART OF THESE PLANS. 16. ALL REQUIREMENTS OF THE NPDES PERMITS SHALL BE MET. 17. A GRADING PERMIT WILL NOT BE ISSUED UNTIL THE TOWN OF CARY HAS RECEIVED NOTIFICATION FROM THE ECOSYSTEM ENHANCEMENT PROGRAM OR AN APPROVED NUTRIENT OFFSET BANK THAT A RECEIPT HAS BEEN ISSUED TO THE DEVELOPER AND THE LOCAL GOVERNMENT STATING THE NITROGEN BUY DOWN HAS BEEN COMPLETED. 18. ALL LEVEL SPREADERS ON THE PROJECT MUST BE LOCATED ON COMMON OPEN SPACE, HAVE AN ACCESS AND MAINTENANCE EASEMENT LOCATED AROUND THEM AND INCLUDE AN OPERATIONS AND MAINTENANCE AGREEMENT. GRAPHIC SCALE 60 0 30 60 120 P RE ' SEAL NOT AP R VE021 6CO SfRUCTION "Cl 'kA R NORTH AB10 KNOW WHAT'S BELOW. CALL BEFORE YOU DIG. Cary Project Number 14 -SP -049 Cary HTE Number 15 -0029 Approved by the Town of Cary Development Review Committee Planner WITHERS & RAVEN EL ENGINEERS I PLANNERS I SURVEYORS 111 MacKenan Drive Cary, North Carolina 27511 tel: 919- 469 -3340 www.withersravenel.com License No. C -0832 Dote Sheet No. C4.1 B z z W a s a 0 N O o O O o0 v L 3 a z W < z Q w a 0 0 U / U U 3 z it 0 0 0 U 0 U / L 3 L U E E U L 0 z N a O i 0 N o O i i Y a a _170 •.. POND WATER ELEVATION AS OF 12/17/13: 367.2' / / / / / / l\ �•.. • •.tea / I � / / / ' a / / / / / - - / / / / /• _3651 _360 - - SJARMWATEiQ BMP MAINTENANPE ANB AE 355 \ 345 10 �. FO s C POOL 16,400 SF AT EORM = 351..0 / / 10' AQUATIC SHELF / FROM -EL -350.5 TO 351.5 AT 10:1 j I I `360 SS o 1 � to M r I� n I I / M 19 000 M H \� - *PINE +11I1NE -WAY OF WHITE OAK F WAS ESTABLISHED - - > OF THE CENTER OF / •. k0� A OF -THIS SURVEY. BMP #1 - WET DETENTION POND - I"= 30' * DRAWDOWN PIPE TO TURN UP 1' INSIDE STRUCTURE TO ESTABLISH NORMAL POOL BMP #1 DATA PLANT SCHEDULE PEAK CONTROL WEIR: 352.5( DRAWDOWN ORIFICE *: 350.0( BOTTOM DRAIN: 344.2C PEAK CONTROL WEIR: 352.5( NORTHERN WALL SOUTHERN WALL TOP: 355.5 (TYP) WESTERN WALL * DRAWDOWN PIPE TO TURN UP 1' INSIDE STRUCTURE TO ESTABLISH NORMAL POOL 5' (TYP) EASTERN WAL 6 "(TYP) �UJL RISER DETAILS N.T.S. RISER CREST: 353.50 (TYP) 6" (TYP) RISER CREST: 353.50 36" OUTLET INV: 344.00 CLAY LINER SPECIFICATIONS THE CLAY LINER FOR THE WET POND SHALL BE AT LEAST 8" THICK AND MEET THE FOLLOWING SPECIFICATIONS: • UNIFIED SOIL CLASSIFICATION SYSTEM DESIGNATION OF CL, CH, ML,SC • MINIMUM OF 40% PASSING #200 SIEVE • MINIMUM PLASTICITY INDEX OF 12 • MAXIMUM INFILTRATION RATE OF 0.01 IN /HR. • A MINIMUM OF 2 TESTS OF EACH ABOVE PARAMETER SHALL BE COMPLETED BY THE CONTRACTOR ON THE LINER MATERIAL AND PRESENTED TO THE ENGINEER FOR APPROVAL. • COMPACTION TO A MINIMUM OF 93% PER ASTM D698, AND WITHIN 3% OF THE OPTIMUM MOISTURE CONTENT (1 COMPACTION DENSITY TEST PER 2500 SO. FT.) THE CLAY LINER SHALL BE PLACED UNDER THE BOTTOM OF THE BMP PERMANENT POOL TO A THICKNESS OF 8 INCHES. A MINIMUM OF 4 INCHES OF TOPSOIL SHALL BE THE FINISHED GRADE AS SHOWN ON THE DRAWINGS AND /OR DETAILS. CARE SHALL BE TAKEN WHEN TRACKING IN THE TOPSOIL TO NOT PUNCTURE OR DAMAGE THE CLAY. A CLAY /SOIL MIXTURE MAY BE USED IF THE ABOVE SPECIFICATIONS ARE SATISFIED AND WITH WRITTEN APPROVAL BY THE ENGINEER. GRAPHIC SCALE 30 0 15 30 60 SHALLOW LAND (NORMAL POOL TO 6" ABOVE) = 2,848 S.F. 50 HERB. PLANTS / 200 S.F. (2,848 S.F.) = 712 PLANTS DIMENSIONS ELEV. POND BOTTOM BOTANICAL NAME 343.0 TOP OF BERM CALIPER 356.0 NORMAL POOL 16,400 SF 351.0 DRAWDOWN ORIFICE* 2.5" 350.0 PEAK CONTROL WEIR x2 3' WIDE (2 SIDES) 352.5 RISER CREST ELEVATION 5' ID x 5' ID 353.5 OUTLET PIPE INVERT UP 187 LF 36" O-RINGI RCP@ 1.0% 344.0 OUTLET PIPE INVERT DOWN 342.15 * DRAWDOWN PIPE TO TURN UP 1' INSIDE STRUCTURE TO ESTABLISH NORMAL POOL BMP #1 DATA PLANT SCHEDULE PEAK CONTROL WEIR: 352.5( DRAWDOWN ORIFICE *: 350.0( BOTTOM DRAIN: 344.2C PEAK CONTROL WEIR: 352.5( NORTHERN WALL SOUTHERN WALL TOP: 355.5 (TYP) WESTERN WALL * DRAWDOWN PIPE TO TURN UP 1' INSIDE STRUCTURE TO ESTABLISH NORMAL POOL 5' (TYP) EASTERN WAL 6 "(TYP) �UJL RISER DETAILS N.T.S. RISER CREST: 353.50 (TYP) 6" (TYP) RISER CREST: 353.50 36" OUTLET INV: 344.00 CLAY LINER SPECIFICATIONS THE CLAY LINER FOR THE WET POND SHALL BE AT LEAST 8" THICK AND MEET THE FOLLOWING SPECIFICATIONS: • UNIFIED SOIL CLASSIFICATION SYSTEM DESIGNATION OF CL, CH, ML,SC • MINIMUM OF 40% PASSING #200 SIEVE • MINIMUM PLASTICITY INDEX OF 12 • MAXIMUM INFILTRATION RATE OF 0.01 IN /HR. • A MINIMUM OF 2 TESTS OF EACH ABOVE PARAMETER SHALL BE COMPLETED BY THE CONTRACTOR ON THE LINER MATERIAL AND PRESENTED TO THE ENGINEER FOR APPROVAL. • COMPACTION TO A MINIMUM OF 93% PER ASTM D698, AND WITHIN 3% OF THE OPTIMUM MOISTURE CONTENT (1 COMPACTION DENSITY TEST PER 2500 SO. FT.) THE CLAY LINER SHALL BE PLACED UNDER THE BOTTOM OF THE BMP PERMANENT POOL TO A THICKNESS OF 8 INCHES. A MINIMUM OF 4 INCHES OF TOPSOIL SHALL BE THE FINISHED GRADE AS SHOWN ON THE DRAWINGS AND /OR DETAILS. CARE SHALL BE TAKEN WHEN TRACKING IN THE TOPSOIL TO NOT PUNCTURE OR DAMAGE THE CLAY. A CLAY /SOIL MIXTURE MAY BE USED IF THE ABOVE SPECIFICATIONS ARE SATISFIED AND WITH WRITTEN APPROVAL BY THE ENGINEER. GRAPHIC SCALE 30 0 15 30 60 SHALLOW LAND (NORMAL POOL TO 6" ABOVE) = 2,848 S.F. 50 HERB. PLANTS / 200 S.F. (2,848 S.F.) = 712 PLANTS PLANT TYPE QTY KEY BOTANICAL NAME COMMON NAM17 ROOT CALIPER NOTES HERBACEOUS 238 SM Asclepias incornoto Swamp Milkweed CONT. 4" Pot 24" O.C. 1 j � � � j � � • j � j � j � j 0 � j O. j � j i, 237 TS Carex stricto Tussock Sedge CONT. 4" Pot 24" O.C. .............. .............. 237 JW Eupotorium purpureum Joe -pye weed CONT. 4" Pot 24" O.C. No. Revision Date B Designer TLM NOTE: TRASH RACK IS REQUIRED ON THE RISER Drawn By Date BCP /TLM SEE DETAIL THIS SHEET Checked By Job No. ET WATER LEVEL DURING STORM TEMPORARY SKIMMER TOP OF DAM 1 j � � � j � � • j � j � j � j 0 � j O. j � j i, 100 -YR WSE TOP OF RISER .............. .............. NOTE: STAKE THE SEDIMENT CLEANOUT No. Revision Date B Designer TLM NOTE: TRASH RACK IS REQUIRED ON THE RISER Drawn By Date BCP /TLM SEE DETAIL THIS SHEET Checked By Job No. ET WATER LEVEL DURING STORM TEMPORARY SKIMMER TOP OF DAM 100 -YR WSE TOP OF RISER NOTE: STAKE THE SEDIMENT CLEANOUT 10' '� ELEVATION TO 1' ABOVE THE VEGETATED „ PEAK FLOW ATTENUATION POOL 6 RISER �' FOREBAY BOTTOM ELEVATION - SHELF FOREBAY 1 PERMANENT POOL 1 0:1 10' WIDE VEGETATED SHELF TO c� ? PERMANENT 10' EXTEND TO A DEPTH OF 6" ABOVE - POOL DEPTH VEGETATED AND BELOW THE PERMANENT POOL _ l SHELF - BOTTOM .• EARTH DAM 1(- ANTI- FLOATATION DEVICE FOREBAY DRAIN (SEE DETAIL THIS SHEET) ANTI -SEEP COLLAR I I - BMP CROSS SECTION I -_ .--I I F _ _ NTS RCP OUTLET PIPE I I- No. Revision Date B Designer TLM Scale AS NOTED Drawn By Date BCP /TLM 06/26/2014 Checked By Job No. ET 02130427.00 NOTE: SKIMMER MAY VARY SLIGHTLY FROM ILLUSTRATION OUTLET END; CONNECTION TO OUTLET PIPE OR RISER VENT SCREEN ACCESSIBLE THROUGH DOOR FLOAT BARREL PIPE LONGER THAN SHOWN NOT INCLUDED WITH SKIMMER SUPPLIED BY USER FLEXIBLE JOINT (NOT TO EXCEED 3' IN LENGTH) TEMPORARY SEDIMENT DEVICE DEWATERING SKIMMER DETAIL NTS Northwest Community Church Town of Cary Wake County PLAN VIEW CONCRETE ENCASEMENT AT 3000 P.S.I. OR PRE -CAST COLLAR TRASH SCREEN POND BOTTOM TAMPED BLOCKING NOTES: BACKFILL SECTION VIEW 1. ONLY MANUFACTURED VALVE BOX EXTENSIONS SHALL BE ALLOWED. 2. VALVE OPERATING NUT MUST BE EXTENDED SO THAT THE DEPTH IS NO GREATER THAN 5' FOREBAY DRAIN DETAIL MANUUFACTURER APPROVEDftEXT NOSIONHKIT, SURFACE USING A 3. PRECAST CONCRETE ENCASEMENT IS ALLOWED OUTSIDE OF PAVED AREAS. 4. IF FISHING PIER IS CONSTRUCTED AS SHOWN ON THESE PLANS, VALVE BOX SHALL EXTEND TO DECK ELEVATION OF FISHING PIER. OTHERWISE, VALVE BOX TO EXTEND TO TOP OF FOREBAY BERM AS SHOWN IN DETAIL. North Carolina STORMWATER MANAGEMENT PLAN HAND WHEEL IN VALVE BOX RISER CREST OPEN END 4" DIP NORMAL POOL 'O -RING' JOINT 4" DIP TEE - ORIFICE HOLE DRILLED IN 4" DIP CAP 4" DIP -1 POND BOTTOM 4" NRS GATE VALVE (SET IN GROUT) GRATED COVER ACCESS CENTERED OVER STEPS 6" SLAB TOP STAINLESS STEEL STEM SUPPORTS AT 3' O.C. PRECAST REINFORCED BOX 6" THICK SIDEWALL (MIN) MANHOLE STEPS (SEE NCDOT 840.66) 1/4 "x 2" STEEL STRAP W/ 2 - 3/4" ANCHOR BOLTS 2 STRAPS REQ'D GROUT EACH SIDE 6" DIP�_R CAP JOINT SEALED WITH A -LOK NEOPR GASKET (OR APPROVED EQUAL) CAST IN MANHOLE WALL CLASS III 0 -RING RCP INV. OUT `r�, PAVED i f 6 "GROUT :u !. TOP OF • '� ANTI- FLOATATION BMP RISER & DRAWDOWN DEVICE DETAIL VALVE BOX COVER TRASHRACK FOR PEAK CONTROL WEIR #4 REBAR GALVANIZED WITH EPDXY COATING BOLTED TO FRONT OF STRUCTURE WITH STEEL CLAMPS AND CONCRETE ANCHOR BOLTS NTS GRATE OFFSET OVER STEPS 6" PRECAST CONCRETE a: TOP SLAB W/ GRATE ° VOID SPACE ° WEIR OPENING 4' • ° a ' a . 5' x 5' (ID) PRECAST MAX REINFORCED BOX TOP SLAB AND TRASH RACK DETAIL 5.5 5.5'� ELEVATION #4 REBAR 12" O.C. EACH WAY NTS 1/2" PREFORMED JOINT FILLER, 12" WIDE 2000 PSF MIN. 8 °° BEARING CAPACITY BENEATH COLLAR SECTION ANTI -SEEP COLLAR NTS I V V 1 LJ 1. RISER BARREL, SKIMMER AND OUTLET PIPE SHALL BE INSTALLED AT PRIOR TO THE BEGINNING OF OVERALL SITE GRADING AND SHALL BE UTILIZED AS A SEDIMENT CONTROL DEVICE DURING ROADWAY AND UTILITY CONSTRUCTION. ONCE THE SITE HAS BEEN STABILIZED AND GRADING IS COMPLETED THE BASIN SHALL BE CLEANED OUT AND STABILIZED. THE SKIMMER DEVICE SHALL BE REMOVED, THE BOTTOM DRAIN CLOSED AND THE NORMAL POOL ESTABLISHED. 2. ALL CONSTRUCTION TO BE IN ACCORDANCE WITH ALL TOWN OF CARY STANDARDS AND SPECIFICATIONS. THIS PROJECT WILL MEET ALL OF THE REQUIREMENTS RELATIVE TO BEST MANAGEMENT PRACTICES AND ENGINEERED STORMWATER CONTROL STRUCTURES AS OUTLINED IN THE TOWN OF CARY LAND DEVELOPMENT ORDINANCE (CHAPTER 4, PART 4.6, LDO). GRAPHIC SCALE 50 0 25 50 100 a ° KNOW WHAT'S BELOW. �o��Nt CgR''o CALL BEFORE YOU DIG. pF ESS /p q eee P '�ME LI Y Cary Project Number 14-02 -049 Cary HTE Number 15 -0029 NOT APER VEN 6CO SZ-RUCTION Approved by the Town of Cary Development Review Committee °``a �'F;,���,A RD � P�.�`° Planner Dote ln►n�`` WITHERS RAVEN EL ENGINEERS I PLANNERS I SURVEYORS 111 MacKenan Drive Cary, North Carolina 27511 tel: 919 - 469 -3340 www.withersravenel.com License No. C -0832 Sheet No. C7.0