Loading...
HomeMy WebLinkAboutRevised C22007- Sand Filter_CalcsProject: Huber Technology Date: 08.19.2022 Revision: Project No:C22007 By:MD Location: Input values in red Drainage Area 8.33 ac Impervious Area 5.98 ac Percent Impervious 71.81 % Design Rainfall 1.0 in "Schueler's Method" Formula Rv = 0.05 + 0.009(I) where Rv = 0.70 in/in Water Quality Volume Calculation WQv = (Design Rainfall) (Rv) (Drainage Area) WQv = 0.48 ac-ft 21048 ft3 15786 Discounted Design Volume Modified Curve Number: Modified Curve Number CNm = 1000 / [10 + 5P + 10WQv - 10(WQv 2 + 1.25WQvP) CNm = 97 From HydroCAD: WQv Peak 13.72 cfs Sand Filter Sizing Rv = Runoff Coefficient = stormwater runoff (inches) / stormwater rainfall (inches) I = Percent Impervious = drainage area (acres) / impervious portion of the drainage area (acres) 101 N Tryon St., Suite 1400, Charlotte, NC 28202 Tel 704.334.7925 www.stewartinc.com Release Rates: WQv release = 0.115 cfs over 51 hrs Sand Filter Sizing: Filter bed depth (df) 2.50 ft Coeff. of permeability (k) 3.50 ft/day Filter bed drain time (t) 2.125 days hmax filter 4.00 ft (height from top of sand to spillway) hf 2.00 ft Required volume of Sediment Chamber (Vs) = 7893.0 cf Required surface area of Sed. Chamber (As) = 1973.3 sf Required surface area of Sand Filter (Af) = 1973.3 sf Total Surface Area of Pond =3946.5 sf 2700 sf OK 16200 cf OK 2700 sf OK Elevation Area (sq ft) Area (ac)Avg Area Inc Height (ft) Inc Vol (ac-ft) Acc Vol (ac-ft) Ht (ft) 769.00 5400 0.1240 0.1240 0 0.000 0.000 0.00 770.00 6426 0.1475 0.1357 1.00 0.136 0.136 1.00 771.00 7524 0.1727 0.1601 1.00 0.160 0.296 2.00 772.00 8694 0.1996 0.1862 1.00 0.186 0.482 3.00 Underdrain System Design: Minimum drawdown discharge: WQv = 21048 ft3 Drawdown = 0.1146 cfs Perforation Capacity: Total pipe length 180 ft pipes spaced 10' o.c. maximum Number of perforations 2880 holes (3/8" holes spaced 3" o.c., along 4 rows spaced at 90°) 50% of perforations 1440 holes h 2.00 ft Capacity per hole 0.008 cfs Total capacity 11.891 cfs Perforation capacity > filter capacity?YES Underdrain Pipe Capacity: Pipe size 6 inch Pipe slope 0.005 ft/ft Capacity of pipe 0.395 cfs 50% assuming clogging 0.198 cfs Capacity of pipe half clogged > filter capcity?YES Provided Af = Af =(WQv) (df) (k) (t) (hf + df) Provided Vs = Provided As = 101 N Tryon St., Suite 1400, Charlotte, NC 28202 Tel 704.334.7925 www.stewartinc.com Denver, NC + 1.25WQvP)0.5 ] 101 N Tryon St., Suite 1400, Charlotte, NC 28202 Tel 704.334.7925 www.stewartinc.com Qo (cfs) 0.0000 0.1531 0.1969 0.2406 (3/8" holes spaced 3" o.c., along 4 rows spaced at 90°) (WQv) (df) (k) (t) (hf + df) 101 N Tryon St., Suite 1400, Charlotte, NC 28202 Tel 704.334.7925 www.stewartinc.com