Loading...
HomeMy WebLinkAboutWQ0039488_Monitoring - 09-2022_20221013Monitoring Report Submittal Permit Number #* Name of Facility:* Month: * September Report Information WQ0039488 Courthouse Area WWTP Type * Revised - NDMR, NDAR-1, NDAR-2, NDMLR Confirmation Email Address:* Name of Submitter: * Signature: Date of submittal: Initial Review Year:* 2022 Upload Document* CHWWTP 10 13 22 5.02MB REVISED.PDF PDF Only Please upload one PDF containing all applicable monitoring reports (i.e., NDMR, NDAR-1, NDAR-2, NDMLR, GW-59). tsawyer@camdencountync.gov Thomas Sawyer AX94 ,93 ,2or ler Reviewer: Gerald, Wanda 10/13/2022 This will be filled in automatically Is the project number correct?* WQ0039488 Is the monitoring report accepted?* Yes No Regional Office* Washington Reviewer: _anonymous Review Date: 10/28/2022 FORM: NDMR 05-16 NON -DISCHARGE MONITORING REPORT (NDMR) Page of 14 Permit No.: WQ0039488 Facility Name: Courthouse Area WWTP County: Camden Month: September Year: 2022 PI: 001 Flow Measuring Point: ❑ Influent [1] Effluent ❑ No flow generated Parameter Monitoring Point: ❑ Influent Effluent ❑ Groundwater Lowering ❑ Surface Water Parameter Code -0 50050 00310 00940 31616 00610 00625 00620 - 00600 00400 00665 70300 00530 ® ru = Q Q a 0 z e�' E - u- c) E z f- � CL 2 a o c `° 0 1- 4 CO)� aE o u, cn to 1 24-hr 0720 hrs GPD 1 29,111 mg/L mgtL 21100 mL mg/L' mgfL ng/L mg/L su 7.1 mg6L mg/L mgtL 2 07:30 1 17,973 7.1 3 17,973 4 17,973 5 Holiday 17,973 6 07:20 1 27,435 71 7 07:20 1 26,741 5.1 < 1 0.28 1.2 1.4 3.14 6,9 2.08 < 2.5 8 07:20 1 35,871 7. 9 07:20 1 18,687 68 10 18,687 11 18,687 12 07:30 1 26,999 7.1 13 07:29 1 29,489 6.8 14 07:40 1 26,558 6.9 15 07:40 1 28,566 6.9 16 07:40 1 19,913 7 17 19,912 181 19,912 19 0720 1 26,187 7.1 20 07:56 1 30,134 6.9 21 07:30 1 30,798 6.7 22 07:20 1 31,650 < 2.0 < ] 0,35 1.54 2.29 4.52 6.7 2.76 < 2.5 23 07:20 1 21,374 6.7 24 21,373 25 21,373 26 07:40 1 17,977 6.9 27 07:20 1 27,869 6.9 28 07:15 1 29,948 6.9 29 07:41 1 29,422 6.8 301 07:40 1 1 30,563 7.1 31 Average: 24,5 11 2.55 1 00 0.32 1.37 1.85 3.83 2 42 0.00 Daily Maximum: 35,871 5.10 1.00 0.35 1.54 2.29 4.52 7.20 2.76 2.50 Daily Minimum: 17,973 Sampling Type: Recorder 2.00 Composite Composite 1.00 Grab 0.28 Composite 1.20 Composite 1.40 Composite' 3.14 Composite 6.70 Grab 2 08 Composite Composite' 2.50 Composite Monthly Limit: 99,890 10 14 4 10 4 2 15 Daily Limit: Sample Frequency: Continuous 2 X Month 3 X Year 2 X Month 2 X Month 2 X Month 2 X Month 2 X Month 5 X Week 2 X Month 3 X Year 2 X Month FORM: NDMR 05-16 NON -DISCHARGE MONITORING REPORT (DR) Page 9 of Permit No.: WQ0039488 Facility Name: Courthouse Area WWTP County: Camden Month: September PPI: 002 Flow Measuring Point: ❑Influent ❑Effluent ❑ No flow generated Parameter Monitoring Point: ❑ Influent ❑ Effluent ❑ Groundwater Lowering ❑ Surface Water Parameter Code ► 50050 00940 31616 00610 00620 00400 00665 '' 70300 76 W ® t3 Of 0 c O ar N L).c � LL t3 li,, O 0 c q �' 0 U V1 24-hr 1 hrs GPD mg/L #f100 mL mg/L mg/L su mgtL mg/L 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 Average: #DIVIOI Daily Maximum: 0 Daily Minimum: Sampiing Type: 0 Reorder Grab Grab Grab Grab Grab Grab Grab Monthly Limit: Daily Limit: 130,000 250 1.5 10 6.5-8 5 500 Sample Frequency: Continuous Monthly Monthly Monthly Monthly' Monthly Monthly Monthly FORM: NDMR 05-16 NON -DISCHARGE MONITORING REPORT (NDMR) Page of -- Permit No.: WQ0039488 Facility Name: Courthouse Area WWTP County: Camden Month: September PPI: 01 Flow Measuring Point: ❑ Influent ❑ Effluent ❑ No flow generated Parameter Monitoring Paint: ❑ Influent ❑ Effluent ❑ Groundwater Lowering ❑ Surface water Parameter Code — 60060 00940 31616 00610 00620 00400 00665 70300 a Q >_ Q c C E Q O �' Q :�. O E E < z CL V) > I p_u o 1 24-hr 07:20 hrs I GPD 1 608 mg/L /100 mL mg/L mg/L su mg/L mg/L 2 07:30 1 72 3 72 4 72 5 Holiday 72 6 07:20 1 168 4 7 07:20 1 1,084 134 22 0.16 1.43 6.9 1.18 630 8 07:20 1 0 9 07:20 1 0 10 0 11 0 121 07:30 1 0 13 07:29 1 0 14 07:40 1 0 15 07:40 1 0 16 07:40 1 186 17 185 181 185 19 07:20 1 0 20 07:56 1 0 21 07:30 1 0 22 07:20 1 0 23 07:20 1 0 24 0 25 0 26 07:40 1 0 27 07:20 1 0 28 07:15 1 0 29 07:41 1 976 30 07:40 1 25,394 31 Average: 969 134.00 2200 0.16 1.43 1.18 630.00 Daily Maximum: 25,394 134.00 2200 0.16 1,43 6.90 1.18 630.00 Daily Minimum: 0 Sampling Type: Recorder 134.00 Grab 2200 Grab 0.16 Grab 1.43 Grab 6.90 Grab 1,18 Grab 630.00 Grab Monthly Limit: Daily Limit: 130,000 250 1.5 10 6.5-8 5 500 Sample Frequency: Continuous' Monthly Monthly monthly Monthly Monthly Monthly Monthly FORM: NDMR 05-16 NON -DISCHARGE MONITORING REPORT (NDMR) Page Of Sampling Person(s) Certified Laboratories Name: Jovon D. Taylor Name: Environment 1, Inc. Name: 11 Name: Does all monitoring data and sampling frequencies meet the requirements in Attachment A of your permit? 0 Compliant PI Non -Compliant If the facility is non -compliant, please explain in the space below the reason(s) the facility was not in compliance. Provide in your explanation the date(s) of the non-compliance and describe the corrective action(s) taken. Attach additional sheets if necessary. PPI001 Over Limit on Phosphorus - Extra flows from schools starting up for the year. PPI003 Over Limit on TDS Operator in Responsible Charge (ORC) Certification Permittee Certification ORC: Jovon D. Taylor Permittee: Camden County Certification No.: 1010297 Signing Official: Charles A. Jones Jr Grade: 3 Phone Number: 252-333-7372 Signing Official's Title: Public Works Manager Has the ORC changed since the previous NDMR? El Yes E-1 No Phone Number: 252-340-3040 Permit Expiration: 1/31/2023 Alt A) Signature Date Signature Date By this signature, I certify that this report is accurrate and complete to the best of my knowledge. I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that all qualified personnel properly gathered and evaluated the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. plete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations. Mail Original and Two Copies to: Division of Water Resources Information Processing Unit 1617 Mail Service Center Raleigh, North Carolina 27699-1617