Loading...
HomeMy WebLinkAbout20220785 Ver 1_Pre-Filing Meeting_20220419Da t e P l o t t e d : M a r 1 7 , 2 0 2 2 - 5 : 4 3 p m P l o t t e d B y : K S T O N E Z : \ C A D \ 2 0 2 0 \ 2 0 0 2 0 4 H _ W i l l i a m s G r o v e P h a s e 4 \ C I V I L \ D e s i g n \ D r a w i n g \ C A D \ W E T L A N D S I M P A C T S \ W E T L A N D S - S I T E P L A N . d w g WI L L I A M S G R O V E - P H A S E 4 RE S I D E N T I A L S U B D I V I S I O N R E V I S I O N S # DA T E DE S C R I P T I O N BY DATE SCALE DRAWN BY NSR JOB NUMBER DRAWING FILE LAYOUT TAB 1051 N. Winstead Avenue - P.O. Box 7533 Rocky Mount, North Carolina 27804 North Carolina Firm No. P-0551 V: 252.977.3124 F: 252.985.6026 JoynerKeeny Planning, Surveying & Engineering JK PLLC 200204I PRELIMINARY NOT FOR CONSTRUCTION 100 0 100 200 SCALE: 1" = 100 Feet RA-20-CU DIMENSIONAL REQUIREMENTS MINIMUM LOT SIZE = 20,000 SF MINIMUM LOT WIDTH = 100 FEET BUILDING SETBACKS: ROAD RIGHT-OF-WAY = 35 FEET SIDE PROPERTY LINE = 12 FEET CORNER SIDE PROPERTY LINE = 17.5 FEET REAR PROPERTY LINE = 25 FEET SI T E P L A N - S H . 1 O F 2 1"=100' WETLANDS IMPACT DRAWINGS WL- 04 SITE PLAN - SH. 1 OF 2 WE T L A N D S I M P A C T D R A W I N G S 03/17/2022 REPRESENTATIVE BUILDING, PATIO, AND DRIVEWAY LOCATIONS SHOWN ON LOTS HAVING BUFFERS OR WETLANDS. FINAL BUILDING SIZE AND LOCATION NOT DETERMINED AT THIS TIME. Da t e P l o t t e d : M a r 1 7 , 2 0 2 2 - 5 : 4 3 p m P l o t t e d B y : K S T O N E Z : \ C A D \ 2 0 2 0 \ 2 0 0 2 0 4 H _ W i l l i a m s G r o v e P h a s e 4 \ C I V I L \ D e s i g n \ D r a w i n g \ C A D \ W E T L A N D S I M P A C T S \ W E T L A N D S - S I T E P L A N . d w g WI L L I A M S G R O V E - P H A S E 4 RE S I D E N T I A L S U B D I V I S I O N R E V I S I O N S # DA T E DE S C R I P T I O N BY DATE SCALE DRAWN BY NSR JOB NUMBER DRAWING FILE LAYOUT TAB 1051 N. Winstead Avenue - P.O. Box 7533 Rocky Mount, North Carolina 27804 North Carolina Firm No. P-0551 V: 252.977.3124 F: 252.985.6026 JoynerKeeny Planning, Surveying & Engineering JK PLLC 200204I PRELIMINARY NOT FOR CONSTRUCTION 100 0 100 200 SCALE: 1" = 100 Feet RA-20-CU DIMENSIONAL REQUIREMENTS MINIMUM LOT SIZE = 20,000 SF MINIMUM LOT WIDTH = 100 FEET BUILDING SETBACKS: ROAD RIGHT-OF-WAY = 35 FEET SIDE PROPERTY LINE = 12 FEET CORNER SIDE PROPERTY LINE = 17.5 FEET REAR PROPERTY LINE = 25 FEET SI T E P L A N - S H . 2 O F 2 1"=100' WETLANDS IMPACT DRAWINGS WL- 05 SITE PLAN - SH. 2 OF 2 WE T L A N D S I M P A C T D R A W I N G S 03/17/2022 TEMPORARY WETLANDS IMPACT PERMANENT WETLANDS IMPACT INSET SCALE: 1" = 20 Feet SWAMP REPRESENTATIVE BUILDING, PATIO, AND DRIVEWAY LOCATIONS SHOWN ON LOTS HAVING BUFFERS OR WETLANDS SHOWN TO ILLUSTRATE THERE IS SUFFICIENT SPACE TO BUILD HOMES WITHOUT DISTURBING BUFFERS OR WETLANDS. FINAL BUILDING SIZE AND LOCATION NOT DETERMINED AT THIS TIME.