HomeMy WebLinkAbout20211818 Ver 2_USACE Permit_20220714U.S. ARMY CORPS OF ENGINEERS WILMINGTON DISTRICT Action Id. SAW-2016-01125 County: Wake U.S.G.S. Quad: NC-Bayleaf GENERAL PERMIT (REGIONAL AND NATIONWIDE) VERIFICATION Permittee: Kris Bass Engineering Kris Bass Address: 219 E. Chatham Street, Suite 205 Cary, NC 27511 Size (acres) ~37 acres Nearest Town Raleigh Nearest Waterway UT to Lower Barton Creek River Basin Neuse USGS HUC 03020201 Coordinates Latitude: 35.918451 Longitude: -78.705392 Location description: The project site is south of Wood Valley Drive on the north side of Macon Road near its intersection with Macon Ridge Road in Raleigh, Wake County, North Carolina. Description of projects area and activity: This verification authorizes the permanent discharge of fill material within 40 linear feet (0.007 acres) of stream channel, the permanent discharge of fill material resulting in no loss of waters within 100 linear feet of stream channel, the permanent discharge of fill material within 0.028 acres of wetlands and the permanent discharge of fill material within 0.04 acres of open water. Applicable Law(s): ☒Section 404 (Clean Water Act, 33 USC 1344) ☐Section 10 (Rivers and Harbors Act, 33 USC 403) Authorization: NWP 3. Maintenance and NWP 18. Minor Discharges SEE ATTACHED NWP GENERAL, REGIONAL, AND/OR SPECIAL CONDITIONS Your work is authorized by the above referenced permit provided it is accomplished in strict accordance with the attached Conditions, your application signed and dated 3/7/2022, the ensuing administrative record and the enclosed plans. Any violation of the attached conditions or deviation from your submitted plans may subject the permittee to a stop work order, a restoration order, a Class I administrative penalty, and/or appropriate legal action. This verification will remain valid until the expiration date identified below unless the nationwide and/or regional general permit authorization is modified, suspended or revoked. If, prior to the expiration date identified below, the nationwide and/or regional general permit authorization is reissued and/or modified, this verification will remain valid until the expiration date identified below, provided it complies with all requirements of the modified nationwide permit. If the nationwide and/or regional general permit authorization expires or is suspended, revoked, or is modified, such that the activity would no longer comply with the terms and conditions of the nationwide permit, activities which have commenced (i.e., are under construction) or are under contract to commence in reliance upon the nationwide and/or regional general permit, will remain authorized provided the activity is completed within twelve months of the date of the nationwide and/or regional general permit’s expiration, modification or revocation, unless discretionary authority has been exercised on a case-by-case basis to modify, suspend or revoke the authorization. Activities subject to Section 404 (as indicated above) may also require an individual Section 401 Water Quality Certification. You should contact the NC Division of Water Resources (telephone 919-807-6300) to determine Section 401 requirements. For activities occurring within the twenty coastal counties subject to regulation under the Coastal Area Management Act (CAMA), prior to beginning work you must contact the N.C. Division of Coastal Management Morehead City, NC, at (252) 808-2808. This Department of the Army verification does not relieve the permittee of the responsibility to obtain any other required Federal, State or local approvals/permits. If there are any questions regarding this verification, any of the conditions of the Permit, or the Corps of Engineers regulatory program, please contact George Lyle Phillips III at (919) 554-4884 X25 or George.L.Phillips@usace.army.mil. Corps Regulatory Official: _____________________________________________________Date: 7/14/2022 Expiration Date of Verification: 3/14/2026 The Wilmington District is committed to providing the highest level of support to the public. To help us ensure we continue to do so, please complete the Customer Satisfaction Survey located at http://corpsmapu.usace.army.mil/cm_apex/f?p=136:4:0 Copy furnished: Colleen Cohn – NCDEQ-DWR – 3800 Barrett Drive, Raleigh, NC 27609 Action ID Number: SAW-2016-01125 County: Wake Permittee: Kris Bass Engineering, Kris Bass Project Name: Hsu Pond Spillway Repairs Date Verification Issued: 7/14/2022 Project Manager: George Lyle Phillips III Upon completion of the activity authorized by this permit and any mitigation required by the permit, sign this certification and return it to the following address: US ARMY CORPS OF ENGINEERS WILMINGTON DISTRICT Attn: George Lyle Phillips III Raleigh Regulatory Office U.S Army Corps of Engineers 3331 Heritage Trade Drive, Suite 105 Wake Forest, North Carolina 27587 or George.L.Phillips@usace.army.mil Please note that your permitted activity is subject to a compliance inspection by a U. S. Army Corps of Engineers representative. Failure to comply with any terms or conditions of this authorization may result in the Corps suspending, modifying or revoking the authorization and/or issuing a Class I administrative penalty, or initiating other appropriate legal action. I hereby certify that the work authorized by the above referenced permit has been completed in accordance with the terms and condition of the said permit, and required mitigation was completed in accordance with the permit conditions. _______________________________________ ______________________ Signature of Permittee Date SR 1833 - MACON ROAD Sheet 1 of 5 KB KB KB Kr i s B a s s E n g i n e e r i n g Ra l e i g h , N C Kr i s B a s s 91 9 . 9 6 0 . 1 5 5 2 ( c ) kb a s s @ k b e n g . o r g Ma c o n R o a d Ra l e i g h , N C HS U P o n d P r o j e c t HS U P O N D S P I L L W A Y I M P R O V E M E N T S FI N A L D R A W I N G F O R P E R M I T R E V I E W MACON ROAD HSU POND SPILLWAY REPAIRS 9313 MACON RD RALEIGH NC WAKE COUNTY DAM AND SPILLWAY AREA PROPERTY BOUNDARY VICINITY MAP PROJECT CONTACTS: PROJECT ENGINEER KRIS BASS ENGINEERING PHONE: 919.960.1552 EMAIL: KBASS@KBENG.ORG PRIMARY CONTRACTOR RUFTY HOMES PHONE:970.389.4014 EMAIL: MICHAEL@RUFTY.COM SCHEMATIC Sheet 2 of 5 Kr i s B a s s E n g i n e e r i n g Ra l e i g h , N C Kr i s B a s s 91 9 . 9 6 0 . 1 5 5 2 ( c ) kb a s s @ k b e n g . o r g Ma c o n P o n d R o a d Ra l e i g h , N C HS U P o n d P r o j e c t HS U P O N D S P I L L W A Y I M P R O V E M E N T FI N A L D R A W I N G F O R P E R M I T T I N G EXISTING DAM Feet 0 30 60 SCALE: 1IN=30FT MACON RD DRAIN PIPE ERODED SPILLWAY ROCK OUTCROP BROKEN CONCRETE/ DEBRIS EXISTING CONTOURS EXISTING WETLAND EXISTING WETLAND NEUSE BUFFER NEUSE BUFFER El e v a t i o n 353.00 354.00 355.00 356.00 357.00 358.00 359.00 360.00 361.00 362.00 363.00 364.00 365.00 366.00 367.00 368.00 369.00 370.00 371.00 372.00 0+ 0 0 . 0 0 0+ 0 5 . 0 0 0+ 1 0 . 0 0 0+ 1 5 . 0 0 0+ 2 0 . 0 0 0+ 2 5 . 0 0 0+ 3 0 . 0 0 0+ 3 5 . 0 0 0+ 4 0 . 0 0 0+ 4 5 . 0 0 0+ 5 0 . 0 0 0+ 5 5 . 0 0 0+ 6 0 . 0 0 0+ 6 5 . 0 0 0+ 7 0 . 0 0 0+ 7 5 . 0 0 0+ 8 0 . 0 0 0+ 8 5 . 0 0 0+ 9 0 . 0 0 0+ 9 4 . 5 0 Sheet 3 of 5 Kr i s B a s s E n g i n e e r i n g Ra l e i g h , N C Kr i s B a s s 91 9 . 9 6 0 . 1 5 5 2 ( c ) kb a s s @ k b e n g . o r g Ma c o n P o n d R o a d Ra l e i g h , N C HS U P o n d P r o j e c t HS U P O N D S P I L L W A Y I M P R O V E M E N T FI N A L D R A W I N G F O R P E R M I T T I N G FILL/IMPROVE CORNER LOWER DAM ~3FT REMOVE TREES CLEAR/GRUB FILL/SOFTEN SLOPE RE-ESTABLISH IN GRASS EXTEND PIPE OR ABANDON BACKFILL AREA STONE SPILLWAY W BOULDER STEP POOLS BOULDER TOE/ TERRACE NOTES: 1.PROJECT AREA: 0.5 AC 2.TREE REMOVAL: 25-30 3.EARTHWORK': 900CY 4.CLEAR AND GRUB: 0.2 AC 5.JUNCTION BOX 6.NEW PIPE: 40LF HDPE 7.BOULDERS: 150 TONS 8.CLASS 1 AND 2 STONE: 150 TONS 9.CLASS A AND B STONE: 50 TONS 10.PLANTING: 6,000 SF 11.SEEDING: 0.4 AC ADDITIONAL NEEDS 1, POND SIPHON 2. PUMPING 3. EROSION CONTROL MATTING BOULDER SPILLWAY PROFILE Feet 0 30 60 SCALE: 1IN=30FT PROPOSED CONTOURS TEMPORARY ACCESS PATH Sheet 4 of 5 Kr i s B a s s E n g i n e e r i n g Ra l e i g h , N C Kr i s B a s s 91 9 . 9 6 0 . 1 5 5 2 ( c ) kb a s s @ k b e n g . o r g Ma c o n P o n d R o a d Ra l e i g h , N C HS U P o n d P r o j e c t HS U P O N D S P I L L W A Y I M P R O V E M E N T FI N A L D R A W I N G F O R P E R M I T T I N G WETLAND IMPACT 580 SF TEMPORARY WETLAND IMPACT = 666 SF PERMANENT WETLAND IMPACTS = 580 SF OPEN WATER IMPACTS = 1,584 SF TOTAL IMPACTS: 2,830 SF = .065 AC TEMPORARY STREAM IMPACT = 100 LF PERMANENT STREAM IMPACT = 40 LF Feet 0 30 60 SCALE: 1IN=30FT WETLAND IMPACT 666 SFNEUSE BUFFER NEUSE BUFFER TEMPORARY BUFFER IMPACTS ZONE 1 = 362 SF ZONE 2 = 271 SF PERMANENT BUFFER IMPACT ZONE 1: 1,346 SF ZONE 2: 396 SF EXISTING DAM FOOTPRINT OPEN WATER IMPACT 1584SF TEMPORARY STREAM IMPACT 100 LF PERMANENT STREAM IMPACT 40 LF TEMPORARY BUFFER IMPACTS ZONE 1 = 362 SF ZONE 2 = 271 SF TOTAL = 633 SF PERMANENT BUFFER IMPACT ZONE 1 = 1,346 SF ZONE 2 = 396 SF TOTAL = 1,742 SF = 0.04 AC 360.00 362.00 364.00 366.00 368.00 370.00 372.00 374.00 376.00 378.00 380.00 0+00.00 0+59.38 Sheet 5 of 5 Kr i s B a s s E n g i n e e r i n g Ra l e i g h , N C Kr i s B a s s 91 9 . 9 6 0 . 1 5 5 2 ( c ) kb a s s @ k b e n g . o r g Ma c o n P o n d R o a d Ra l e i g h , N C HS U P o n d P r o j e c t HS U P O N D S P I L L W A Y I M P R O V E M E N T FI N A L D R A W I N G F O R P E R M I T T I N G SPILLWAY CROSS SECTION BOULDER SILL FILTER FABRIC FACE AND COARSE STONE BACKFILL SPILLWAY PLAN DETAIL MIXED STONE SPILLWAY WELL MIXED STONE SIZES FLAT INSTALLATION BOULDER STEPS 7 SETS, 10 FT SPACING LOW FLOW MICROPOOLS BOULDER WALL TIE-IN BOTH SIDES BOULDER EXIST SILL TIE TO NATURAL GRADE EXTEND BOULDER TOE ALL BOULDER SILLS AND STEPS TO BE BACKFILLED WITH MIXED SIZES OF COARSE STONE TO ELIMINATE GAPS POOLS TO BE LINED WITH MIXED STONE LOWERED BASEFLOW BOULDER FOR LOW FLOW CONTROL EXISTING PROPOSED