HomeMy WebLinkAboutSW6221006_Supplement-EZ Form_20221025SUPPLEMENT-EZ COVER PAGE
FORMS LOADED
IPROJECT INFORMATION
1 Project Name
2 Project Area (ac)
3 Coastal Wetland Area ac
4 Surface Water Area ac
5 Is this project High or Low Density?
6 Does this project use an off -site SCM?
+/-20,000-SF Distribution Facility Expansion for
CCBCC-Fayetteville
13.7
0
0
High
No
COMPLIANCE WITH 02H .1003(4)
7
Width of vegetated setbacks provided feet
No surface water on project area
8
Will the vegetated setback remain vegetated?
N/A
9
If BUA is proposed in the setback, does it meet NCAC 02H.1003 4 c-d ?
N/A
10
Is streambank stabilization proposed on this project?
NUMBER AND TYPE OF SCMs:
11
Infiltration System
12
Bioretention Cell
13
Wet Pond
1
14
Stormwater Wetland
15
Permeable Pavement
16
Sand Filter
17
Rainwater Harvesting RWH
18
Green Roof
19
Level Spreader -Filter Strip (LS-FS)
20
Disconnected Impervious Surface DIS
21
Treatment Swale
22
Dry Pond
23
StormFilter
24
Silva Cell
Bayfilter
IFilterra
25
26
FORMS LOADED
IDESIGNER CERTIFICATION
27
Name and Title:
28
Organization:
29
Street address:
30
City, State, Zip:
31
Phone numbers :
32
Email:
Ethan Hart, P.E. - Civil Engineer
Fitts and Goodwin, Inc.
120 Corporate Blvd.
West Columbia, SC 29169
(803) 331-2991
ehart(a-)strateaisse.com
Certification Statement:
I certify, under penalty of law that this Supplement-EZ form and all supporting information were prepared under my direction or supervision; that the
information provided in the form is, to the best of my knowledge and belief, true, accurate, and complete; and that the engineering plans, specifications,
operation and maintenance agreements and other supporting information are consistent with the information provided here.
Seal
Signature of Designer
Date
DRAINAGE AREAS
1
Is this a high density project?
Yes
2
If so, number of drainage areas/SCMs
1
3
Does this project have low density areas?
No
4
If so, number of low density drainage areas
0
5
Is all/part of this project subject to previous rule
versions?
No
FORMS LOADED
DRAINAGE AREA INFORMATION
Entire Site
1
4 Type of SCM
Wet Pond
Wet Pond
5
JTotal drainage area (sq ft
596772
351529
6
Onsite drainage area (sq ft
596772
351529
7
Offsite drainage area (sq ft
0
0
8
Total BUA in project (sq ft
325828 sf
325828 sf
9
New BUA on subdivided lots (subject to
ermitting) (sq ft
10
New BUA not on subdivided lots (subject to
ermittin s
31798 sf
31798 sf
11
Offsite BUA (sq ft
12
1 Breakdown of new BUA not on subdivided lots:
- Parking (sq ft
31798 sf
31798 sf
- Sidewalk (sq ft
- Roof (sq ft
- Roadway s ft
- Futures ft
- Other, please specify in the comment box
below (sq ft
294030 sf
13
New infiltrating permeable pavement on
subdivided lots (sq ft
294030 sf
14
New infiltrating permeable pavement not on
subdivided lots (sq ft
15permitting)
Existing BUA that will remain (not subject to
s ft
16
Existing BUA that is already permitted (sq ft
17
Existing BUA that will be removed (sq ft
18
Percent BUA
55%
93%
19
Design storm inches
1.0 in
1.0 in
20
Design volume of SCM cu ft
47195 cf
47195 cf
21
lCalculation method for design volume
Simple
Simple
ADDITIONAL
INFORMATION
22
Please use this space to provide any additional information about the
drainage area(s):
Expansion to existing site resulting in a net increase of 0.73-ac (31,798-sf)
impervious area.
WET POND
Drainage area number 1
]ra,
Minimum re uired treatment volume cu ft
3850 cf
GENL MDC FROM 02H .1050
3
Is the SCM sized to treat the SW from all surfaces at build -out?
Yes
4
Is the SCM located away from contaminated soils?
Yes
5
What are the side slopes of the SCM (H:V)?
3:1
6
Does the SCM have retaining walls, gabion walls or other engineered
side slopes
No
7
Are the inlets, outlets, and receiving stream protected from erosion
10- ear storm)?
Yes
8
Is there an overflow or bypass for inflow volume in excess of the
desi n volume?
Yes
9
What is the method for dewatering the SCM for maintenance?
Pump (preferred)
10
If applicable, will the SCM be cleaned out after construction?
Yes
11
Does the maintenance access comply with General MDC (8)?
Yes
12
Does the drainage easement comply with General MDC (9)?
Yes
13
If the SCM is on a single family lot, does (will?) the plat comply with
General MDC 10 ?
N/A
14
Is there an O&M Agreement that complies with General MDC (11)?
Yes
15
Is there an O&M Plan that complies with General MDC (12)?
Yes
16
Does the SCM follow the device specific MDC?
Yes
17
Was the SCM designed by an NC licensedprofessional?
Yes
WET POND
MDC FROM 02H .1053 MMMA
18
Sizing method used
HRT
19
Has a stage/storage table been provided in the calculations?
Yes
20
Elevation of the excavated main pool depth (bottom of sediment
removal) (fmsl
Elevation of the main pool bottom (top of sediment removal) (fmsl)
Elevation of the bottom of the vegetated shelf (fmsl)
Elevation of the permanent pool (fmsl)
Elevation of the top of the vegetated shelf (fmsl)
Elevation of the temporary pool (fmsl)
85.50
86.00
21
22
90.13
23
90.63
24
91.13
25
93.63
26
Surface area of the main permanent pool (square feet)
10223
27
Volume of the main permanent pool (cubic feet)
28367 cf
28
Average depth of the main pool (feet)
3.22 ft
29
Average depth equation used
Equation 3
30
If using equation 3, main pool perimeter (feet)
529.0 ft
31
If using equation 3, width of submerged veg. shelf (feet)
3.0 ft
32
Volume of the forebay (cubic feet)
4433 cf
33
Is this 15-20% of the volume in the main pool?
Yes
34
Clean -out depth for forebay (inches)
37 in
35
Design volume of SCM (cu ft)
47195 cf
36
Is the outlet an orifice or a weir?
Orifice
37
If orifice, orifice diameter (inches)
3 in
38
If weir, weir height (inches)
39
If weir, weir length (inches)
40
Drawdown time for the temporary pool (days)
2.31
41
Are the inlet(s) and outlet located in a manner that avoids short-
circuiting?
Yes
42
Are berms or baffles provided to improve the flow path?
Yes
43
Depth of forebay at entrance (inches)
48 in
44
Depth of forebay at exit (inches)
43 in
45
Does water flow out of the forebay in a non -erosive manner?
Yes
46
Width of the vegetated shelf (feet)
6 ft
47
Slope of vegetated shelf (H:V) _
Does the orifice drawdown from below the top surface of the
permanentpool?
6:1
48
No
49
Does the pond minimize impacts to the receiving channel from the 1-
r, 24-hr storm?
Yes
50
Are fountains proposed? (If Y, please provide documentation that
MDC(9) is met.
No
51 Is a trash rack or other device provided to protect the outlet system?
52 Are the dam and embankment planted in non -clumping turf grass?
53 Species of turf that will be used on the dam and embankment
Yes
Yes
Bermuda
54
Hasa planting plan been provided for the vegetated shelf?
Yes
ONAL INFORMATION
551 Please use this space to provide any additional information about the
wet pond(s):
Wet Pond 3 2:26 PM 10/25/2022