HomeMy WebLinkAboutWQ0003626_Engineering Certification_20130731Permit No. WQ0003626 Campbell Soup Supply Company, LLC Maxton Plant& Silgan Can Company WWTP ENGINEERING CERTIFICATION Wastewater Irrigation System July 31, 2013 Robeson County ❑ Partial ® Final In accordance with 15A NCAC 02T .0116, I, Daniel B. Wilkinson. as a duly registered Professional Engineer in the State of North Carolina, having the Permittee's authorization to © periodically 0 weekly ❑ fully observe the construction of the permitted facility, hereby state to the best of my abilities that due care anddiligence was used in the observation of the construction, such that the facility was built within substantial compliance and intent of this permit, the Division approved plans and specifications, and other, supporting documentation. ❑ Any variation to this permit, the Division approved plans and specifications, and other supporting documentation has been documented in the attached as -built drawings, and shall serve as the Permittee's minor modification request to amend the permit accordingly. Provide a brief narrative description of any variations: Tha attachpri mPmnrandrrm is a summary _of minnr variations frnm the approved plans and specifications through construction of Phase II. Daniel`B: Wilkinson Professional Engineer's Name Dewberry Engineers, Inc. Engineering Firm 2301 Rexwoods Drive_ Suite 200 Mailing Address Raleigh i 27607 City I State Zip 919-881-9939 I dwilkinson©dewberry.com Telephone 1 ° E-mail NC PE Seal, Signature & Date THE COMPLETED ENGINEERING CERTIFICATION, INCLUDING ALL SUPPORTING INFORMATION AND MATERIALS, SHALL BE SENT TO THE FOLLOWING ADDRESS: NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES DIVISION OF WATER QUALITY AQUIFER PROTECTION SECTION LAND APPLICATION UNIT By U.S. Postal Service; By Courier/Special Delivery: 1636 MAIL SERVICE CENTER 512 N. SALISBURY ST. RALEIGH, NORTH CAROLINA 27699-1636 RALEIGH, NORTH CAROLINA 27604 WQ0003626 Version 3.2 Shell Version 130607 Page 11 of 11 Dewberry° MEMORANDUM Date: 20 December 2013 To: Nathaniel Thornburg, NCDENR, Aquifer Protection Section — Land Application Unit Fiore: Daniel Wilkinson, PE Subject: Final Engineering Certification — Campbell Soup Supply Company,. Maxton, NC, (WQ0003626) Message: Dewberry. is providing final engineering certification for construction of Phase II of the wastewater storage lagoons at the Campbell Soup Supply Company (CSSC) in Maxton, NC (Non -Discharge Permit WQ0003626). Phase II improvements generally consist of construction of Lagoon 2 (approximately 26 million gallons storage) with HDPE liner, the force main from the existing irrigation pumps to Lagoon 2, the lagoon wash down hydrant system, piping interconnections between Lagoon 2 and the lagoon pumping station and Lagoon 1. CSSC has contracted with BMCO Construction to serve as general contractor for construction of the lagoons and pump station. CSSC has contracted separately with Plastic Fusion Fabricators for installation of the lagoon liner systems. CSSC has contracted with Yonkers Industries to provide daily construction management and oversight services. CSSC has contracted with Froehling & Robertson, Inc. to provide third part quality control testing services. CSSC has contracted with Dewberry to provide construction phase engineering services. Construction phase engineering services has included addressing questions regarding select submittals upon request and periodic inspections. Engineering inspections for Phase. II construction were conducted. by Ryan. Ames on 20 November, 4 December, 12 December, and 17 December, 2013. Dan Wilkinson also attended the 17 December site visit to observe substantial completion of Phase II construction. Upon completion of Lagoon 1 and acceptance of the partial certification dated 30 October 2013, Lagoon 1 was placed in service, and B Field was taken out of service so that Lagoon 2 grading and berm construction could be completed. This final certification is being provided based on substantial completion of the Lagoon 2 liner system. As of the writing of this memo the liner deployment, seaming and QA/QC testing has been completed. Per discussion with the Fayetteville regional office, providing the certification and liner QA/QC data at this stage allows for review and acceptance of the liner system prior to introducing wastewater into the lagoon. The following punch list items remain to be completed: • Backfill and compact anchor trench; • Install batten strips to seal liner to the top of the level sensor stilling well in Lagoon 2;. • Finish grading on outer slopes of Lagoon 2 berm; • Finish grading of lagoon pump station access road and storm drainage swale and placement of gravel on the access road; • Installation of pipe bollards around lagoon pump station; • Installation of flexible couplings on lagoon pump station suction and discharge piping; • Installation of ladder and hand rail on pump station wet well; • Install concrete collars around valve boxes on buried valves for wash down hydrant system; • Reinstall fencing and second motorized gate; • Seeding and stabilization; • Removal of temporary erosion and sediment control measures. Memorandum j 1 of 2 Dewberry MEMORANDUM These punch list items do not affect the primary functions of the lagoon system and related pumps, force mains, and control systems. Completion of most punch list items is anticipated in January 2014, however it may be necessary to complete final seeding and removal of temporary erosion and sediment control measures during the spring of 2014. Record drawings will be provided after punch list items are completed. The following is a summary of minor variations from the approved plans and specifications through substantial completion of Phase 11: • The electrical enclosure for the lagoon pump station control panel and MCC-B was originally designed for outdoor service. Concrete masonry walls were extended around the landing where the electrical enclosure was located, and a roofwas constructed over this area. This modification was made in the field at the owner's request to provide additional protection against vandalism for the electrical equipment. These changes do not affect the intended function of the system. • The 12-inch valve on the force man from the irrigation pump station to Lagoon 2, downstream of the magnetic flow meter and motorized flow control valve, was installed in a concrete vault instead of direct burial. The valve was supplied with an actuator that was not suited for direct burial. For construction schedule purposes, the valve was installed in a vault rather than re- ordering the valve. This change does not affect the intended function of the system. • The 12-inch valve on the force man from the irrigation pump station to Lagoon 2, downstream of the wash down branch pipes, was installed in a concrete vault instead of direct burial. The valve was supplied with an actuator that was not suited for direct burial. For construction schedule purposes, the valve_was installed in a vault rather than re -ordering the valve. This change does not affect the intended function of the system. • The Lagoon 2 level sensor stilling well was intended to be installed on the top of the berm, outside the liner anchor trench, as shown on Sheet C-9 of the approved plans. The stilling well was constructed prior to construction of much of the Lagoon 2 berms. Due to a layout error, the stilling well was located inside the anchor trench. A decision was made on site not to move the stilling well. A boot was constructed of textured HDPE liner material and extended to the top of the stilling well. The top of the stilling well is slightly higher than the top of the berm and less than two feet above the lowest point at which the berm intersects the stilling well, therefore the stilling well is expected to be outside the high water line of Lagoon 2. This change does not affect the intended function of the system. Quality control reports for the installation of the HDPE liner in Lagoon 2 are included with this certification. Field quality control and testing reports include: subgrade inspection and acceptance certificates, daily trial weld testing data, numbered panel layout, daily deployment log with non destructive (pressure) testing data, field destructive testing results, and a repair log with locations of each repair described. Reports for third -party destructive testing is also included. The cover letter for the third -party destructive test report by Froehling & Robertson summarizes the minimum requirements for test results and indicates that all destructive tests met passing criteria. CC: Jim Barber, NCDENR Fayetteville Regional Office, Aquifer Protection Section Greg Westbrook, CSSC Jamie Collins, CSSC Sam Howell — Yonkers Katie Jones - Dewberry Ryan Ames - Dewberry Memorandum 12 of 2 Field Test Data www.dewberry.com PLASTIC FUSION FABRICATORS, INC. TRIAL SEAM LOG NO. DATE TIME AMB. TEMP TYPEJ NO. TEMP. ' SPEED SHEAR SHEAR SHEAR PEEL PEEL PEEL OP. D,4,1__ arvi 11A5 -3 e° s\do 4 W-` 5. 1--M_ I 0 1? 3 1);16 13)0 157 145 151 13 I, S\i 3e --71.7 411/45° 5.5 1 °C.) 1015 11-7 \\„R ilfli- 138 pP5 1).3 137 )G"i 15 LI- 1 5 tv II) 07 12,D 1119 117 /00 ih. /3 5 a., .-. vAs- '' 71-1 4-\s' q,g )(v3 li.;_\ ok-k. 0_0 1)ci p.ib 1..1, ia_l 135 -Arto cAvol. s.-' ‘.;_5 'k 2_ \\A 33 11 la V 7 3 21 - .."-) la--ns T-3\4 Y1' ,. 5-A. " iso/Ao° 4efriAAA 1V . )52 1S'k . 0-1 " fgo..111Prr ))? prr °- 6"G`) -11A /) '0 ° 0 )5., )5'-lo 1551 1)3 lb? OK 11°\ 116 ji7 5,j2 g'\ --i-,' c- 13, °W-3 0. sbo Tr? it 1 b° 5, b )5 I I 11-14- ) il el) 133 )21 117 jgb 'al DT, 12-.5-13 1..).‘14r--s .71,(), 1)-.)1Y) 15.2,, 10_, 152_ til... 115 /e3.5 i ILI- 115 kit+ .-r. N., .7-?-2 910' 9\-° l50 ' 15.5- 1_5 10-, I,2° P,I in 122— II? 3'.. r1.5 tg,sb a -V./..)1.,0° 4.,,-)-0! ,I -__-,' 2. ! b ! t; '..1 - iie Hs ,-.7---- , \ ) G 5_./ nil Ell KO 1151 1 ° 11) 5 Mal i 55 • 03 0j/c' '7 b GN. riell1/371 13 INE1h5 / 2-- /b-5' VII its rigi k,),_ -OS r)-1,•ri /at q5 71-1 tnb . 5,S /37 IT p'f. 113 HQ, ia.0 114- )13 loli. .215-- 0 y iv ' 5.-5 11 13 G i - 3 (s, li 6 ' 3-: /0 9 /27 /07 ibe ,,i2„ NIL 71 g 79-0 Tilb )t)I - f ,i) 19 15 1 jr),F pe iae 0 IT 1,z3 -7-)-.1 ID° ,..s ) / 3a / dO )2. 113 3 1 3c) A443 7,' 30 . ,/ 777 li/C 5,S" )7) /7/ /f3 1/7 0..6) /3/, 4,L. 2- --)_, ec? -26b 4- lo ' ' it,• 1 70 ZS 11111 0-5 i7S /2-2. i1A, I Mily 73' laIll 1Y ' . p 114\ )17 STA . in, A), 112_ A_I-195' i k.)? p., _ a,561/444 It4,-4L tpfe 1 (0 : I -- I 3-0 ti°\ PLASTIC FUSION FABRICATORS, INC. TRIAL SEAM LOG NO. DATE TIME AMB. TEMP TYPE/ ' NO., TEMP.. . SPEED ' ; SHEAR SHEAR SHEAR . • ' PEEL PEEL " 'PEEL ' OP: 0. 13-13 :uo - . CI.. 71 hrfank VI \ ., 1 7 i fl 12.,E ;\ . \.*24. 117 133 ill AP a-' \1-A3 \''> '\) S 1:oT a-- 2Av146 t or Ili).. i% ? 1 s. ? _ (, 1 g 1.1 6 ► l 8' 1171. IV') II 7 • /► Lt.5 11,!4 • ►i `))1t) '1'i -1.- i!/-)1I Ar ' 1'0414 I lA 1 71- 1 0 °\ 11 Q1 1 `2,1 . I 1 °1 11 C7 id..,) 1 q . Pt1,k, 1'Y1,p, ,\1- g A-1\0 13. - '. ( • 3, S VS/MA IbI'(w.A„t- 1 to to s t 3 1 L4F f a 1 11 b . Ili • ) rot la-3 1 l c\ PLASTIC FUSION FABRICATORS, INC, DAILY DEPLOYMENT DEPLOYMENT PANEL ROLL WIDTH LENGTH NO, NO. I OS a.-,S ciA/ -1-(5 3 31 ( V-6. 14' S a.1-1- 5L(51 (P 0' lito r 33 I 514' 31- 35' 5-bi. it 37\ if 2,(,.., t/ )4-5 S1,451 DATE: 41A3 • SEAMING RECORD PRESSURE TEST QC INIT. PSI TIME SEAM NO. OPER. MACH. NO LF OF WELD START/ STOP START / STOP i - Al '6 5 6i5 .v)-.--, 0 5 0 "POI 71 t 1) .2-3 ii,,),-, `7 77 5 _,`-. 2 lb 7i)--1, 7f, 14 3- 0 J, k "Pt/D 5' 5 le) 31) 71,16 1';'6° 4'-5 AvA 5,u-D .1.' 'M 3 o 7/gi 73 ILL, 177 SLQ.' 7d I 6 1/ r W31 le-7. g'4,715' 3( ?O 7t9q' 7a1 --Jq TO 5T2: 16 70 71qb 7t15( .41,4 °I kil... TO s-5-'21 3d la •-My/ 71S7 ‘,‘- • 13 4 tail 5-Do C-).S.2' pi 36 71 s•6 7/•55 pi- l( :1,12_. 7‘ LI '-'52-: ff - - .-36( 7 ic—z_.7tct7 ii-n_ A/6 5--ob 5-5-i.; lr 36 F110 'ti PLASTIC FUSION FABRICATORS, INC. DAILY DEPLOYMENT DEPLOYMENT • PANEL NO, ROLL NO. WIDTH LENGTH 0 af) gs1-(s si45 DATE: 1/1-,q--- A,0)3 SEAMING RECORD PRESSURE TEST QC INIT. PSI TIME SEAM NO. OPER. MACH. NO LF OF WELD START/ STOP START / STOP 47, ' / 3 irkh -yd7) grls: a0 itr OW tol,),5 & 711) 4.224 S' 3 b ib ()if/3A Slid 13-15j j'4. .7/2 CV,' Yl) A • 1LIV P 2 / 102/7 . . PLASTIC FUSION FABRICATORS, INC. DAILY DEPLOYMENT DEPLOYMENT PANEL NO. ROLL NO. WIDTH LENGTH I6 ° . a e /sly.' ' F1' jr lA 377' aA i 5- y. aa,,.1- a. (#; ,Z.3 /a 2— „C .3 ) s "L-) il1 1 ' a.? 11- tom ' 41 3`) ' 31 4! 93. 2-41 (65 1 ?' ?,3 it T L1ctl: 37 . q.3 I IN', 115a: (ii ak -3 ( `)a°-- 93 1 44 93 \ J 5 , i S' S . 55' Di ,.V 55 5 q • DATE: i1'd5-d0/3 SEAMING RECORD `� PRESSURE TEST QC INIT. PSI TIME SEAM NO. OPER. MACH. NO LF OF WELD START / STOP START / STOP 15-42 ktk, 1737 q-1,' 311 31) iv 30 ii) kw /1,-) MA 'O ug l ' ad -jc) ,Ui'n ,tfl11' 1 FL ?JO.:/ c31k, '1 lib 7' 16 70 iovii-1.10 •'' SS' cr,I WO n..t s 10 ?s Os el ci 11-.• /" - it-0 ;ai3 12. 1 ( 'ji 5S' iota . r A,S Cab 3R ;..' 3O 10 314t its old'etI /-z,U 1n•A 5Gb e2a,` 3d n 4' 1d;3-4 L2 3 `' 1iD5 S'fii) L)? ' b 3 7 —21'�4 2r i 1-)-9- ) 7'77 ( . 11 aVf) e 5 c, +- z,'� in4 5d D ? 9 'O. 90 } l 1 °l, Its 21.I- Z52-a2G+ hm incti 2db 9d o ,alb _050 L7 4• 777 V' -30 7 (j 1 /,'Zii :25, ` ,j 2J 11'25 W-1Gt o-= ft, , Soo q v 3o /,s- /'?,'5C AI- 4',4. 7)7 311, id lb 116P PM D-33 A ba 4 )-J 3D 1112/6 /JrOa 31 -'33- 1m 4 S'D b 1 ,6 " 30 30 At 0 aV ' 3+; 2-LfA 11).. Ile '94 3a r,q1 1 6 i l -354 A j 7-3'7 ail. 30 s 0 " , di, 1'2-1 3L-) 5 cJ A. -10 II? ` -,'6 7 u ,,z G¢ L. 2,,17 35- 34- At TOD iCif' ,v 5v ,..tz., ,7,i/7 34-37 kJ.. `7`17 qg la yd zi'93 i'9? 3.7,,3i t3 500 W' 30 3d '1f ozj4.i 3F` 3( sA, iJf) "e21 3U 2,145 S: f�4e 1c - za, s 3i) 3 2/ U 5 alto *4v1 Sot 7?i 30 3d al9s aTO yi`O." IMA 3- A._ ?/U Y" -3a 36 trj /1•8.5. yz4 3 A,,.- 777 ' 7' 3d o 3,0( 3 d 11j- 94 Alb COO i6` 36 30 3t U --- 5167 i `9•6•' SSA ?Ld L/ff' 34 3a ./1 31I1, 31R3i.F- PLASTIC FUSION FABRICATORS, INC. DAILY DEPLOYMENT DEPLOYMENT PANEL ROLL WIDTH LENGTH NO. NO. Y) O5 6 t' eft n 1 (a' 4t 55' 5(i va..i r Sod., WI 55 ,16, j g-3, 5 ' a"fc, a Z,V O'i 0,6 Y'l LO 47 ' 1. 1'1 'Jo ivy K2_. (4' DATE: 11 " L O'41073 SEAMING RECORD PRESSURE TEST QC INIT. PSI TIME SEAM NO. OPER. MACH. NO LF OF WELD; START / _ STOP START / STOP .y 5 Q L � 1K. W 'b , 1 , U 36 91.2 `? ` 2-s 4 L 7 j/, '110'0 . 5;a' -nr . _ ? b 9 t•&- ° t t°7 ` - 4K ivi i5, 5'! ,_--�'2' 3 0 D qj 2i`3 l ()y '/9- 5'b Mil v 3b ilr i'U 30 i!' 11 ,iil 9G- 'i',k,:r5 s'1�.$--'5-4` 7 0 3D i.il. ' 1121 citi36 Q - 5'} -,,., -Net, 3' 30 31) °r ya c/- 52- iiii6 9 i0 SY 3b 3b /, ,s opio 5, -53 (Ti* it4 _ 70 16 30 11) 10127 5 ~ 0 A/5 i b 5 Ft 3O 3b /01f2,5 JO%'? 51/"55 611, 2 1` 3 90 610 10L3 5-I-56, %m'A 0U 71' 36 3) ea 'PSI , s-1 -57ja '44 tr 36 ?p 107 i`5.2, 5-2-5? SKI 7/4) VI --11 36 /WOO 10:e V~ bb -, /1,, 76..6 gall di) 36 /01t) )014,s '/ -4- 06-b/ (IAL`7 O ' 3d 36 j1j 1 4/`6 _ c A 74-L) ibP' 36. PO / p 13 s f 114- 0. ?- 55 c'!' /'c, g- t6 / 5-' 78 36 VS'VS1 tr Sir [�27. ?8 D � 74) 10 IOT /0� 5'�_ 12s j9` 4'6 Al,- 77? 2?7- 33 33 f; 36 Tf,✓ --, Jg, `ts iit -pm_ ft/6 pi 3 /D 9.3 , f 43Ail us- coi ojL PLASTIC FUSION FABRICATORS, INC. DAILY DEPLOYMENT DEPLOYMENT PANEL ROLL WIDTH LENGTH O. !/N_ tlNO. 'N A-j 'J'` _r La' if J, 5 / r� is 1 ‘f ( g•104 (97 NI-1 4 / 47 91. o ` o ld. (, i fig. 497' 10.: � 11 2' ---741.1 Ski " 7n ta(. DATE: Ja.- / - c0)3 SEAMING RECORD PRESSURE TEST QC INIT. PSI TIME SEAM NO. OPER. MACH. NO LF OF WELD START / STOP START / STOP J_, 9 *A 5a-d �5-.'_ 30 'YO 1Ir 14.3 ,q-(5 £L, `777' Sb : 30 , 31) 71d�'"L - 747 GS-b,, dt ,,, 7b-o SCO i) 30 `70-S' `7! O CgL.-b 7 Ate, ;'OJ S'6PA 30 30 T7 -/ 7 h 17-6q LL, 77 Or 3tl 30 7W 74)3 6 9' 71 LI k. 74,0 9 6g 3O so 7! 17 7r yz •/ gOd 3SV 30 3D 7!i9 71/A _71-7.3rf 7/-7i' Atiti 51) I)P. 16 -,5b -7I11 7I `7 -7 L1 / . L 777 L `, , 30 , 30 71,0e 7: r'3 7G`77 3', it -) (-?IS o 3 U 30 70S 7U 4J-Ui /'-,/-, 777 215 30 10 16,7,0 Ik2,5 79-1)' ,4 6 5bD aa,.s 3v 3o iri2d iita,s' 7L.-73 6 AS gab xl,s -31) 3v n 9u 1i.91 7N- ?c 7,1t -)(.0 xi,s 3o -3b /rigs pl'SO L[JLS Ai- PLASTIC FUSION FABRICATORS, INC. A DAILY DEPLOYMENT DEPLOYMENT PANEL ROLL WIDTH LENGTH NO. NO. 7V- 5 \ &LL s 971. °1 5 n -1�: 5 l il D. 5b - fr• 2. 51 .t • )y' V 7 51 u,,.s sy11 Li S I .5 60' Fs- 51 (9,,,s b2-' ? t, S 1 iAT (, 3' in 51 i.gii' ' L FS 71 ,1,5 619' 611. sz. 407 t) 51 G G " t? 52 L /5 9. S 52-- a' 1,7 sue.- ms U r' DATE: ,%L SEAMING RECORD PRESSURE TEST QC INIT. PSI TIME SEAM NO. OPER. MACH. NO LF OF WELD START / STOP START / STOP -27-7 s, 7i o r-idis 30 30 p1(US I1!!!7 --. _?:': ) 777 )a ` 3b 30 11i 1S' lIi2G A -Kb /L 1., z21 ,5 r' JO 36 /JO'? • 1I i /c'' .6.: )-r' L1k, 76.0 !c 36 36 InoV /103 1-17_` '41)-. fiA 7(,•D .31' 30 3D 3b)-2. 3'27 ?).`F3 1t.1.. 777 °l' 30 30 /t;zs 11i3() ?3�?�- ►1v.7,77 7' "D 10 ili�7 11:3`t-- S3qs it,t1/4-. 777 55-' 0 30 111,y.' /1i56 S'n. 3 3‘2 70 90 20 11;111 11,:cii- Y Vi ('Lk, 7Z7 29' 30 3D 1.2(1S. 1a110 $ 7 j ? / k_ Z 77 5t,' 71 31 03 l .21 Vg---91) 6 JI 12, 760 22-• $ 31) 3o is j o 14 51 ' U-°,0 ci-tit, 7/O --5-R' 31 -Jd iils ii4U 91)111 X,k.777r 5ci' 31 31 lift 1i95 9 -ell- 41L ? 4 0 58' 31 71 I i 5O 1. s's' q-1: 613 ,_L, 777 0-- 32_ 3 z. /i:5`; :4 ue i3-°I 3j. il• 7�0 (0b 11 31 21 dr) 24. US lv,15 JCL. 727 60,4 3o 3o 2/67 atru 75-96 3, IL 160 Gp° 31 31 z1 i7 •2.12: 16 - 3 7 / LS 777 (4' 3 z 31--- z123 -1 PLASTIC FUSION FABRICATORS, INC. DAILY DEPLOYMENT DEPLOYMENT LENGTH PANEL NO. ROLL NO. WIDTH q c\. S T. ,D rt>a ' /, 5' (0) -.-s- -) L 5' 0-357 . 1-5' /b(157 1,s'' 1O 5-7 ,a' /p? s7 1` e 5'3 / 5'' G(-1 5.3 (rya' [11-). -'3 zz,s .Li'' DATE: )a' ia.010) 3 R SEAMING RECORD PRESSURE TEST QC INIT. PSI TIME SEAM NO. OPER. MACH. NO LF OF WELD START / STOP START / STOP `1-°)( a 71,-d '- ?rJ )u )15'6' 07iA 5'11 6 "/.1 7 77 ,22I S 26 36 )O 9s' 1M.6 IN , -)'77 58 30 ib at uu Aa , )oD UiG 1 Si A. 74d q 7 ' 21 U .21-al Zi le /O/-/02- cif- 77? 5--'j' v 36 GD ). U67 /..J -1)1u3 r & /7t43 G 6 ' 10 36 .2to 3 6-ei it,? -lob itvL, 777 63' 3d P-- -71.bs' tilt) !o 4'/0 c.6it 71, 4.3 ` 3v 36 2104 9 J/ /D5-/l/( /L/io `777 ,g9; ltr 30 2Zd7 .v/Z, tO j-1D .4 Ct f , ,k 4.1(3. .7o 36 /LO 1 a DS" /6610'7r'JL ‘7Ga 01 5() 3/ z107 zl/J //7i/Ot itiL 777 h ' -3(f -ya fiol / 10-111, c511L 7 (41' Yo 36 d1/U 4115' 110 -//l if,41 777 (D,' 5o „c IL- JL 17 J1/-J12.. •3'f? 7(,11 66 16 36 2,)/� .20 79-7 i 74,6 .// ' T3 kt. 1A . J?''Ls C013 6 5; f PLASTIC FUSION FABRICATORS, INC. DAILY DEPLOYMENT DEPLOYMENT PANEL ROLL WIDTH LENGTH NO. NO. 10 ja CGS, G1q- � :/ „ (Is 5' ' a5- 1 SI !J•53 /7: Jl1. 5a) /1.a 51 (1 to S-'\ L 0 , >tiS c' aa_, s sr DATE: 7cL-.k%I3 SEAMING RECORD PRESSURE TEST QC INIT. PSI TIME SE/NM NO. OPER. MACH. NO LF OF WELD START / STOP START / STOP to'1,- PS SA,, 74'0 ; i 5 d a` 1S / 1 a tJ 3 `l1 v- AA, '777 gift,:3 U- 30 VI 0 t 3` 111/-1;7 .. 71ft ,2L.3 'M 30 -7.1 aG 3i 0 PP5.-N f , iI ki 777 /?3' 30 ao -3 1) I ?up /17-161% 1'l2 7b1) 2 ' ' 3 3J RACP 'o3 - /J1,`/I P` J-t2.: 7 30 31 3/17 1r2 _ (i2.-iel ,(.. . 777 >'' lid 34) 14.P. 3t3 P l -P-P did. 7(d0 Ti 311 3 d 3132— 3137 -pi iehc . 177 S L' 5o 50 3t 37 349 ),vJL dill, 74.0 501' 3e 30 747 31v, ja1�123 ► ,. 7 '7 5 ' 30 36 31,5 3f s- J 5 p.4- j /L a l .1'4' N 30 tioo ,t 0 s' ilt-I ?_ /2,. 777 q ' 3 11 ,0 9115. ¢1 /sflL - — 3 y l771 ' . 6' N 4"NJ- 4p121,1,- PLASTIC FUSION FABRICATORS, INC. DAILY DEPLOYMENT DEPLOYMENT PANEL ROLL WIDTH LENGTH NO. NO. IV rt. .� d3%. 5 [37-5 7 n lc), /3-q- ‘-a 5 r /35 41 57" /1(60 sr 13` TT/ is-' 19' DATE: iar' 1✓0,.? SEAMING RECORD PRESSURE TEST QC INIT. PSI TIME SEAM NO. 1 OPER. MACH. ' NO LF OF WELD START / STOP START / STOP 616 744 /uFl 3 3o J `,q6 )t ,,-1 6 ,7 ;, , 777 s2; 3 A %V if °�I ia'.. 2 p I , " 71 I d 3,6 qr l9 Us() 3 iicf JAI -130 n 724 s.z , 3 )o 1,10 s /..70-tf1 /L,Ai. 7y� 1 ;lti 36 liv of-1 /v-/ L J)I 7(,>O SO' ,3-6 3l) v fa aO J 3 2173 X) 7 f 7 51' 3rf `ij c.b /11. '-Oi /39-13 ri. 77'7 50' 33 56 /002 10/ 4351/34 U',/ - V 3t! 70 10'O5. lot 10 0141 liivi. '717 I/i' Ai 30 /0:i-o / 82. 43 ?-/.4 A,X , 777 1q' 3o 10: V /013 Z, ilic-/3?(11,if.Z 21 t' , 7G //dZ /1D7 -i i , s Q <L � � �' ! F /4" 3 d 39 6•'Jr z/ , f U -// 1 cJ A. 7(Q j2b' i/J i0 figi.4 //yl-ip 15,770 FtL kgrc), Pouf PLASTIC FUSION FABRICATORS, INC. GEOMEMBRANE SEAM DESTRUCTIVE SAMPLE LOG SAMPLE NO. SEAM NO MACH. NO. QC , MON. SAMPLE 1 SAMPLE 2 SAMPLE 3 SAMPLE 4 SAMPLE 5 REMARKS PEEL SHEAR PEEL SHEAR PEEL SHEAR. PEEL SHEAR PEEL SHEAR t I i'l. 51)0 la°1 i-t) ►1a5 ►a-) 1\1 1143 131 1"30 11,b In Ia-1 I0 1a ,1a3 1�4- sbu' sue. 1, ' /3 TY? lby 1a.9- i' M- in la"1 1 _7 i14_ Lab ibz, no_ ia\ 157 1UR- i - 1t01) 'no'suw . 3 3/ 1- it.o Iat la\ ibb Iat 1D14 1(Lt> ►Q7.)15_ 1b0 134 lig iS°t 13D 13'.) NE) ago s„' y- 415 5OO 13,\ \\5 157,130 1\\ 15.. 11\ 1110 151 i'.D iILI- 11tq I-. i\s 153 33u' 5ky. 5 5/ to -?7 lam 1\4 140.1 Ia3 Illo 151 Pt. 11\0 144 1m 111, 152► 11s i1'1. IS'2. -'-it'' S,A-v, (p 6/"1 -I.n lt' la,v in ill, Ili 1v° 0.4 ias- 1515 la.,k 1311, 12. 13'2 113 161t 1's'7 a\o°Sc I S u' sr).„ -No,„, 7 1 1 S s 01%. 13s 111 167 13 5 134 15C 13r in. IT) 1 a,1e 11? vs-) our iv2i 7 8'7 °i -Fr/ 1 \j 1Y)-. 1 t,,)_ loco 10,1 I V7 no l a.S I b3 ) l l 110 OD 11 b 1 ,,1- i la l alb' S»ti\ °t J I n sin 03 131 l (93 ita I a.4- i t2 4- i 3 i i �t. ! b- J 3 l- 1)3 lob I' 6.. Y2,Z 4 2_ 5 Ito' Su,\A-1-. 10 1v (11 . ? _1\D) 1\0\ 1k \ 1\b ,_115 t51 11? 15$ I\- 1:Z1 1192- 119- 11g ibb s'So` $0 1l \\/I1-- sob la.°1 Ib2, 1b3 to, 111- llb _}Q7 WA- la+, 1103 lat. 1 ..1 l}Os 1t1, . Ita9 i0, 3()1\). Suv.. N 0-- ik/13 50v \-11 i-3b \II- 1\1. \ 3_ 1b°\ tat. 133 1\010 133 '132 . il. b I7.2 1N, nob ifn' v1z 1 ► it" 5ov 131 1\5 I' tag 13' 1\+\ Ixtp la.t:, 1? _ IaS 116 I1eb 12 ice- }v 5•u` jov-1,.., lt? 13/15 ?17 1'31 10) 155 ta.°i.131, 15(a 1d2 ix% 154 1 ,--) 12‘2155 ia5 lad i57 1-1010'� ) ' 45/I1: 111 137 1a1... M 1')- 13V Ite(O 13 1�\ 1 °\ 13`�1i 11 11 \ 143 115 1‘?1•53 ' co i ;fir !Silo ells \'t ..) 135 \'11 \-' 1 `1 q \- 13 °\ \-1 5 13°) 11,1 1 %3 14 \ 111-0 Old S 5' S oN., -. 12 ')-,\-ra5 509 1\ 5 ,ate 1g2 1\'4- la3 ►g1 13eA 134- 11°1 135 111-. I VI. 131 115 13 3 -7` \,3Ltr 1? 31/3z. T71A9 1st, ta\• ITlo___Va1) ab 177 141---118 ISS i9? IDS I1i7 143 IX IF% 1151' -Yi+ _ 1., , 3't f 3? Soo 13g 1/),°t_ t 1 ? 133 115 17 (0 13 7..14 1 E 1 \\°\ 1\5 1? $ 135 13b l? b LH,' 6,1,3i- ' It ' foie b frt f 15 '7bo 1..'°\,13,w- l °l)...14814° ► V \ Wt.Wt. t u11, 1 t `i-,. \5l 1' .7 1411 1`i3 .11 t 1c1b ?7,1 '-a.v( i Top Its Ia`°\ 1107 Its ii7 167 1.31, i.3 163 Ittb lat9 itP, 1?1 fib ib -3` -6uk&-k rid. S 3/ 54. 5 U,,c, 1.0 1,,,.-, Ill I .... I bolt 17 t l ? 1 m t i 4- 1311),(0 171 I 19- 17.3 Sx; . c7 /(3 svo _, 19Z .1`Ii4-. lbtA7 131, 107 13(9 135 1 fool 13(,_ _3z_ 171 )17 132 1(1,7 )1' K-Jk PLASTIC FUSION FABRICATORS, INC. GEOMEMBRANE SEAM DESTRUCTIVE SAMPLE LOG %Kr�L PbJ SAMPLE NO. SEAM NO. MACH. NO. QC MON. SAMPLE 1 SAMPLE 2 SAMPLE.3 SAMPLE 4 ' SAMPLES REMARKS PEEL SHEAR PEEL SHEAR PEEL SHEAR PEEL SHEAR PEEL SHEAR A.,A- 1 / v- 50•K) I'3 135 '12_ t 1tl- I`ti3 115 I\1 133 I/3 115 -113 I`jO )fig 116 175 aoY Go-- . g)..,5 04 J bs f l7 )3°v as 10 131 133 I bb 135 133 110 135 )14- J la7 of )z‘,. • Ado i 4 s' ,a, a, 1,, is/LA/ .tp-,0 no 11 \ Ibs 11) 13z- 171 iac 13s )72- 131 133 t77 13.E 13( 10 701501 ,t 1 W Lc, 0) ta,k.N- ,\°\ f-1 \ 1'1.,, 133 lib las )aL 1 b°1 lX1 133 111 12 1a1 172- 5 115' Sup, N • W i9tli<l so-v ►a.', Iva 114- Imo- I)- 1/3 1a5 137 1?3 1)b 131 172 116 )3 9- 175 'foss ' S6%- l-, 671d,) 777 in 11..E 1°7 + (°1 13; 1i3 1'33 1").:5 173 147 )14; 17 4- 1'fL. t2I. ) 7+ 'd t u ' S41; 0 71/73 Sov, 1.0..11 ia.b 1b 1i'/. la \ '00 11 t,. 1\ 171 1-11 I15 1617 11b 11g. II,7 (ab' sv,4v,\ '; .73 74?- f' Sup.' (-0 t °t 17t' ►La Ia). Ibg 11q 1 171- 132 )17 ) O 1A.4 Hi- i,L, ' 1bu s06,N :--, - in ?bv , (IT 1)Z 171-rd7 112 173 ►i /ug •t75 !t J)s 171> 12 )13 173 5r' S0w 3 "/~fib Tr? I1Al 107- 1&1hP..F161,1 i W. f1`F1'i' i J,,25 123 /41 la7 /1�/I�� 14' 1)Ur � g�/°1t7 71,-0 lad laI / b' 13.) ) . /G( 115 /31 1 ! 13z167 101 jz - /4S 13 ' tots r 35 0 (i°? 777 1.2' 1 J 7), 13$' 115 170 l y 176 -l19 2 117 )71-Ja3 la 7 In' wi- D - ao5/ 777 J,?2 1_15J(,01 )3 lao IG.3 3C> 0-1�D J�1 1013 /6l l�+' )3/ / ' t0, 37 1 yerl -7 tab ) 117 )5 )D 1t.t / °I �S 11 Is't /&I /,44 /5� l 8'I0 1�cS 1�� 1 v4A-1 � � a�,3 1\1'1r -i "l I16 . 1ST 1 jI5 /51 U5 1.1 -150 113 Ian .15't13L 11 g IS CD' 1th?t 3) 11s )10 7 37 '/e )11 � 941 1 I to /3- --'= � 1 �'�' 117 �� 0 tfi 118 1�3 s 1 , �q �..b rt' uo la3 �a� l `?-fib � � 1a. 1 D7 1 s �� 1 13 �, I y- /1 t) /b (915- 7 1)c 11 z 1f )) P 11 1—/5 .l j 9' 4) 13.1/i33 -777 1aS ) ' 15-7_13 in- 156 I & / 5 J� F/3b 1fl./4o )33 iv//'g s'+�sfi �t '14-033 `16o I3 1121 IS a11Y 131- l`j 131-, I 110 5 / � I3 3 III /s v a l � 11 3 f�� ' GJ-t 11 s 43 0000 ?(9,0 )33 /2'7)56 J 4 ilc / dig in /111 /a- /3_..iyj A 11j lc) l' 1 rk- kurt, Pore PLASTIC FUSION FABRICATORS, INC. �,,,,. `PbAA GEOMENIBRANE REPAIR / TESTING LOG REPAIR NO. REPAIR DATE REPAIR TYPE SIZE OPER. MACHINE Na TEST TYPE TEST RESULTS - QA MON. REMARKS' I Ii-$1.13 OS- 1 _a'X y ' PP% sz I P ,'• ,/2 sob' go,.., b5-). 0,' y' pi'p' S (196' -11 3 Di- 3. ,.,,TX `)' \ - ,v3 )--3A- SthANR bi oS 4- (9'Xy 3v' �-4/5 33D' Sbhih S b5-5 oa'xkr 5 VI, a7 D' 51)1;-, (O p- 6 ' X I' - a)t2' s,,kik 5-{,f7 s 7/V iSU• 5.„ xti . I 1 1)5- a' ti ; ► 5- Y/0 5 t 15„,, 10 DS-It. y v' S-) Ji( )1 1- Ds- it a'X v' Ss-o So..'t, 5- 0 /,2.. 300 ,,,- , rz. ,-� a'k o' , s - I�,} r3 � l3 Ca' [/ � i LQ' $�,-�1. s 12/n Z.D. \. 1 ®s , \A` SN V I , 1 s,,k� Si3/I5 4�b'sDw b 15 .'yv' i 17 - n a' �i ' -62 5 5 ` 1 r q 9/ a ti ,, `,, ''''.1:,. 5. 7/57' 94' Anfi .)-- 11-a°\-11 P . 19 ' • s z i P S_I Vi t, /Y ' say REPAIR TYPE: P - PATCH GW — GRIND AND wrI n r _ (-era .- RESULT CODES P PASS F - FAIL TEST CODES: V - VACUM TEST S - SPARK TEST TW-T"WELD - ut5I RUCTIVE SAMPLE I7D' "t 4 n/ sr !r} N rift/a, PLASTIC FUSION FABRICATORS, INC. )-`�r '` Pn14 GEOMEMBRANE REPAIR / TESTING LOG REPAIR NO. REPAIR DATE.' REPAIR ; TYPE ' SIZE OPER_ MACHINE NO. TEST TYPE TEST RESULTS' QA MON. REMARKS ' 3 la- a-' 13 DS- a--2— a' x q ' pi S 2_ V P s- s 3/5 q. ,' 2' W 61- (4,4 D--3 (5`Xy-' 5-c,�/� 11' t�,bT .5 P 1' s-is/i 3 A-' dt P I' T " 16/71 ti 0-7 P a; 1 is/9s el'Nam, S-1/kit .G °I �0 cr;tie - a- 2 X y IQ a'x \) , r S LyfGs /95`codt-\ q 5/64 5 U'sv,: , as' a.k, a')C 9' aD ,i)s- -a,o- \ ;\-' skt.i ' t ds:h01 Ei_9° 'cottl- `}- . ADS 3 O a X 41 5-- 71/73 ka *41 36 bg- 21, _' X q I s ,?,V.77 5 c 01- la- a- a . 1' , s' s-7I/73 4t 3 g , )Qi-; I' il ,4.'r -`� b 'Sr 1 /intt S 3e-1 3 1' -I) 1 1 -L1 p , 1 i° ` 9- I kit if 3 ' sup q P.? i AS! 3 5a4 13 U:1--' a-1J YEK-7. ( N 5 `' P'aiU 1 A s-r 7'S, REPAIR TYPE: P - PATCH RESULT CODES: P - PASS TEST CODES: V - VACUM TEST GIN - GRIND AND WELD F - FAIL S - SPARK TEST C - GAP TW - "T" WELD DS - DESTRUCTIVE SAMPLE ,rn.4/4 oK 72//9" PLASTIC FUSION FABRICATORS, INC. GEOMEMBRANE REPAIR / TESTING LOG REPAIR NO. REPAIR DATE . REPAIR TYPE SIZE OPER. MACHINE NO. TEST TYPE TEST RESULTS' CIA MON. REMARKS '- (a)-a-)3 ii.i2A, 11 PIN 5-2" I1 P --7 i ' 5 Li- 6 1' t 15''Suti.i L i 1' P-7 a' Sum 3 ki IS` 1' 1` (tZ-- I Stl 'k 1 \te 1' Pb.9('ci141) 3; Sb ) . s)1 ('.611 Cj l 1' P` sa ) ' stit 3 s .� I -a )' \IA,w �' p-64 (' 0,,r1". 3. Ja,-3 -13 Wb\t, ,, (Q'X 5.0. _ P- Z l () ' ►�WW T S' [ 6'xSa" /3-yj ''lUer . 1;1 5 i' �)(50 P-zs (t ' » , To. 5 u\ ' .SO' z _ r-' -1 1-b-t3 Dc- ?3 a'x `i ' 5-7°r/Po 1't'ma sti\ D -sLI 3:X1 1 s-2/)D 13'1A.),-: b\ 0-35 el,,Xy' s e,U/ 7 JO'f0:c 673 I,1 13 P S Y). 5--byJl2 4- iuirJ4 if.'t p ' Y-15 i 'w - j 5 P i' v'-1 1' 0.td- 3' N L Ia-►a.-1 P f ' - P'1- T'wt-.S. A REPAIR TYPE: P - PATCH RESULT CODES: P - PASS —"ST CODES: V - VACUM TEST GW - GRIND AND WELD F - FAIL S - SPARK TEST C - CAP 7W - "T" WELD r-4 DS - DESTRUCTIVE SAMPLE PLASTIC FUSION FABRICATORS, INC. GEOMEMBRANE. REPAIR / TESTING. LOG REPAIR NO.� li 7 S to-e1 7)/Y 7.� 75. 7 b. 77 bs r 7 r5 REPAIR DATE' I�r13�13 i'`13' 13'. REPAIR TYPE Q 3r m iJal)Zw►�;,�, Cn t)s-yl <D 5- b v 3 SIZE. )' 11 A x �r ax ' ax 61)(50' 1' I' REPAIR TYPE: P'- PATCH RESULT CODES: P PASS TEST CODES: V=.VAGUM-TEST :OPER... MACHINE NO. :TEST, TYPE :TEST, RESULTS'? V. p 10-7 A :PT ;i. GW ,= GRIND AND WELD. C - CAP. F - FAIL S;- SPARK`TEST ;I QA'MON. REMARKS P-5 q.' Wert I , p- b ";at 5i1V' 5 ll b/izoi .-1��...I,.r.,.�►v Ia?J' g2/i) s '►:- 73 •11 1£/41--f` 5•I -_/ 4_ °1. Wes S� IpVjD , IS'1j4li7r, p" : li'5Gr-k Owy'50' F-:74/4y ./2; /3'177 9 a rfi 1.'1 DS - DESTRUCTIVE SAMPLE. PLASTIC FUSION FABRICATORS, INC. GEOMEMBRANE REPAIR / TESTING LOG REPAIR NO. REPAIR DATE REPAIR TYPE SIZE OPER. MACHINE NO. TEST TYPE TEST RESULTS CIA MON. REMARKS e al 1171'3 -0 usl,ti,-,C? 1, 5-2— J P P-1Ui 4I 64.00 AEI D V,ILA y{ p,9b �,Jtnj� �, tt. a) U � 1 ) P-91 y > , � a c\a� v4 I t > nY /-Fs y'X.I,l a'Pu 93 i-r3-13 \) , ) V P� 4's.h, a' IA, el`- is-Ib- i P, c�' x la' A PT P'Fs s " sett, D °y5 it,1. L'X )i' APB P-ia) s's,,,I- 7' P-)2Y L'ANf-.)- 1'N, °! (v is-16'13 ¢P;p� ,s�;11-l'olk. Ia•)(1 : ti r N. REPAIR TYPE: P - PATCH GW - GRIND AND WELD. C - CAP TIN - "T' WI Il RESULT CODES: P - PASS F - FAIL TEST CODES: V - VACUM TEST S - SPARK TEST APT- - MrPrtss,,c e^-t. ies . SV Kmtt. • "1- - • &r: : • `--11111. 4,- . • ' t, " tb t N9 45A 1 . `rd• _ _ _ ' r— --,..,--- ,;4 c......, • A.0,' c.- • ' ' • ,,..- 1 ' :-.‘,.P., 4-2,5, ,,,-,-----,,-..-:- -,,- :,.":.r.1;•=';;.,-.; ., J. ' ':-..: "."-- -----,.. '.. .,---.4.4.:...„-;,,,-.4v- -„..,v, :-..,,,.,,,, ,...?,4 -"""' „.,..--- , ,, -.,--.--.--.-,...-- --v-iv,..- eZ:r P-71 L 1 P- P• I P- 1 p - (°5' 64 •: R- R- o_ 111115:in ' t . \ , Lab Test Data www.dewberry.com FROEHLING & ROBERTSON, INC. Engineering Stability Since 1881 327 East Jenkins Street Fayetteville; North Carolina 28306 I USA T 910.323.9832 I F 910.323.5455 NC License # F-0266 December 18, 2013 Mr. Gregory D. Westbrook Design Engineer Campbell Soup Supply Co., LLC Maxton Manufacturing Facility 2120 NC HWY 71 North Maxton, North Carolina 28364 Reference: Results of Geomembrane Liner Destructive Testing "B" Field Expansion — Lagoon No. 2 Campbell Soup Supply Company, LLC Maxton, North Carolina F&R Record No. 64R-0033 Dear Mr. Westbrook: This letter transmits the results of destructive testing (peel and shear) performed on samples of the HDPE geomembrane liner installed by Plastic Fusion Fabricators, Inc. on Lagoon No. 2 at the subject site. The samples were obtained by Plastic Fusion Fabricators, Inc. during the period from December 3 to December 16, 2013 and given to F&R for testing. The samples were tested in accordance with ASTM D6392-12, Standard Test Method for Determining the Integrity of Non -Reinforced Geomembrane Seams Produced Using Thermo -Fusion Methods as prescribed in the project specifications. h results met "fhe miriiinumvalueseels 121 lbf n:' shearijl`;for. 60 milLghiickness�:geomembrane:-as 7indicated itUtfie. Iff oJett7specifications Table 1.12.6A, Minimum Weld Values for HDPE Geomembranes for Fusion Welded Seams. cf fie EP71Break asC, ifiCallonkCod`e {SEMPlisted on the attached results is referenced in Figure 3, Locus -of - Break Codes for Dual Hot Wedge Seams in Unreinforced Membranes Tested for Seam Strength in Shear and Peel Modes, included in the attached ASTM D6392 iThedbr a c(es&iption for the3SEjl•cn:�_eiis (!sted0 :„.as 4..break_.rn the=Quterredge o#`the'rseam ineitt-fd thelopyor botternisheet3 Corporate HQ: 3015 Dumbarton Road Richmond, Virginia 23228 T 804.264.2701 F 804.264.1202 www.fandr.com VIRGINIA • NORTH CAROLINA • SOUTH CAROLINA • MARYLAND • DISTRICT OF COLUMBIA A Minority -Owned Business F&R, Inc. appreciates the opportunity to provide destructive testing services during this phase of your project as your materials consultant. If you have any questions, please feel free to contact us at your convenience. Sincerely, FROEHLING & ROBERTSON, INC. ,LS Michael W. Sloan, PE Senior Engineer A. Craig Mintz_ Fayetteville Branch Manager Attachments: Peel and Shear Test Results,Destructive Seam Testing ASTM D6392 64R0033, Campbell Soup, B Field Expansion\Peel & Shear\Peel And Shear Results Letter.doc Campbell Soup Supply Company— Report No. 1 "6" Field Expansion - Maxton, NC F&R Record No. 64R-0033 November 15, 2013 2 PEEL AND SHEAR TEST RESULTS DESTRUCTIVE SEAM TESTING ASTM D 6392 CLIENT: CLIENT PROJECT: PROJECT NO.: LAB ID NO.: MATERIAL: SEAM TYPE: Geotechnics INTEGRITY IN TESTING FROEHLING & ROBERTSON, INC. CAMPBELL'S SOUP SUPPLY "B" FIELD EXPANSION L13118-03 L13118-03-01 60 MIL HDPE DOUBLE FUSION SAMPLE I.D.: DS-1 PEEL ADHESION REPLICATE No. PEAK LOAD EPA BREAK CLASSIFICATION PEEL INCURSION (Ibs/in) CODE (%) OUTSIDE -TRACK (WELD 'A") 1 121.0 SE1 <10 2 121.8 SE1 <10 3 121.0 SE1 <10 4 122.7 SE1 <10 5 125.7 SE1 <10 AVERAGE 122.4 STD. DEV. 1.75 INSIDE TRACK (WELD-"B") 1 113.6 SE1 <10 2 114.6 SE1 <10 3 121.1 SE1 <10 4 123.7 SE1 <10 5 125.0 SE1 <10 AVERAGE 119.E STD. DEV: 4.67 BONDED SEAM (SHEAR) STRENGTH REPLICATE No. PEAK LOAD (Ibs/in) EPA BREAK CLASSIFICATION CODE 1 144.3 SE1 2 150.6 SE1 3 144.9 SE1 4 145.4 SE1 5 146.9 SE1 AVERAGE 146.4 STD. DEV. 2.26 CHECKED BY: C'.' DATE: -6-1� C:1Exca Temptatesl(HDP&S-DFusion.x(s]Sheet1 11GEDSERVER1Date DdvelSynthatics12013 SYNTHETICS1118 - PEA - CAMPBELLSI(L13118.03 CAMPBELLS DS-1.xis(Sheetl L13118-03-01 1216/13 544 Braddock Avenue • East Pittsburgh,: PA 15112 • 412-823-7600 • FAX 412-823-8999 • www.geotechnics.net PEEL AND SHEAR TEST RESULTS DESTRUCTIVE SEAM TESTING ASTM D 6392 CLIENT: CLIENT PROJECT: PROJECT NO.: LAB ID NO.: MATERIAL: SEAM TYPE: eotechnics FROEHLING & ROBERTSON, INC.. CAMPBELL'S SOUP SUPPLY "B" FIELD EXPANSION L13118-03 L13118-03-02 60 MIL HDPE DOUBLE FUSION SAMPLE I.D.: DS-2 PEEL ADHESION INTEGRITY IN TESTING INTEGRITY IN TESTING REPLICATE No. PEAK LOAD EPA BREAK CLASSIFICATION PEEL INCURSION (Ibs/in) CODE (%) OUTSIDE TRACK (WELD "A') 1 113.9 SE1 <10 2 116.7 SEI <10 3 111.7 SE1 <10 4 113.6 SE1 <10 5 _ 112.4 SE1 <10 AVERAGE 113.7 STD. DEV. 1.72 INSIDE TRACK (WELD "B') 1 107.8 SE1 <10 ` 2 116.0 SE1 <10 3 111.2 SE1 <10 4 106.9 SE1 <10 5 114.8 SE1 <10 AVERAGE 111.3 STD. DEV. 3.63 BONDED SEAM (SHEAR) STRENGTH REPLICATE No. PEAK LOAD (Ibs/in) EPA BREAK CLASSIFICATION CODE 1 149.8 - SEI 2 149.1 SE1 3 149.2 SE1 4 147.3 SE1 5 148.7 SE1 AVERAGE 148.8 STD. DEV. 0.84 CHECKED BY: 0 DATE: t-a - % - i 3 C:IExcellTemplatesl(HDPSS-DFuslon x'siSheetl 1VGEOSERVER1Data DmelSynthslics12013 SYNTHETICS1118 - F&R - CAMPBELLSI]L13118.03 CAMPBELLS 0S-1,xls]Sheet1 L13118-03-02 12013 544 Braddock Avenue • East Pittsburgh, PA 15112 • 412-823-7600 • FAX 412-823-8999 • www.geotechnics.net PEEL AND SHEAR TEST RESULTS DESTRUCTIVE SEAM TESTING ASTM D 6392 CLIENT: CLIENT PROJECT: PROJECT NO. LAB ID NO.: MATERIAL: SEAM TYPE: FROEHLING & ROBERTSON, INC. CAMPBELL'S SOUP SUPPLY "B" FIELD EXPANSION L13118-03 L13118-03-03 60 MIL HDPE DOUBLE FUSION SAMPLE I.D.: DS-3 PEEL ADHESION otechnics INTEGRITY IN TESTING REPLICATE No. PEAK LOAD EPA BREAK CLASSIFICATION PEEL INCURSION (Ibsen) CODE (%) OUTSIDE TRACK (WELD "A') , 1 126.3 SE1 _ <10 2 130.9 SE1 <10 3 123.5 SE1 <10 4 118.2 SE1 <10 5 1-17.2 SE1 <10 AVERAGE 123.2 STD. DEV. 5.10 INSIDE TRACK (WELD "B") 1 121.7 SE1 <10 2 120.0 SE1 <10 3 109.3 SE1 <10 4 127.1 SE1 <10 5 132.7 SE1 <10 AVERAGE 122.2 STD.' DEV. 7.82 BONDED SEAM (SHEAR) STRENGTH REPLICATE No. PEAK LOAD (Ibs/in) EPA BREAK CLASSIFICATION CODE 1 148.6 SE1 2 153.7 SE1 3 149.9 SE1 4 150.1 SE1 5 150.7 SE1 AVERAGE 150.6 STD. DEV. 1.69 CHECKED BY: )' O DATE: I a-' (a- 13 C:1Exco6Temp la:esl(HDP& S-DFuSion_x4]Sheetl 11GEOSERVERIData DrivalSynthaCcal2013 SYNTNETICS1118 - F&R - CAMPBELLSI(L13118.03 CAMPBELLS DS•2ad51Sheet1 L13116.03-03 12I6/13 544 Braddock Avenue • East Pittsburgh, PA 15112 • 412-823-7600 • FAX 412-823-8999 • www.geotechnics.net PEEL AND SHEAR TEST RESULTS DESTRUCTIVE SEAM TESTING ASTM D 6392 eotechnics INTEGRITY IN TESTING CLIENT: FROEHLING & ROBERTSON, INC. CLIENT PROJECT: CAMPBELL'S SOUP SUPPLY "B" FIELD EXPANSION PROJECT NO.: L13118-03 LAB ID NO.: L13118-03-04 MATERIAL: 60 MIL HDPE SEAM TYPE: DOUBLE FUSION SAMPLE I.D.: DS-4 PEEL ADHESION REPLICATE No. PEAK LOAD (Ibsen) EPA BREAK CLASSIFICATION CODE PEEL ' INCURSION (%) OUTSIDE TRACK (WELD "A") 1 123.7 , SE1 <10 2 121.6 SE1 <10 3 123.2 SE1 <10 4 122.9 SE1 <10 5 . 120.7 SE1 • <10 AVERAGE 122.4 STD. DEV. 1.11 INSIDE TRACK (WELD "B") 1 122.3 SE1 <10 2 1.08.2 SE1 <10 3 122.9 SE1 <10 4 106.1 SE1 <10 5 118.7 .SE1 <10 AVERAGE 115.6 STD. DEV. 7.11 BONDED SEAM (SHEAR) STRENGTH REPLICATE No. PEAK LOAD (Ibs/in) EPA BREAK CLASSIFICATION CODE 1 151.0 SE1 2 152.1 SE1' 3 151.9 SE1 4 156.3 SE1 5 151.9 SE1 AVERAGE 152.6 STD. DEV. 1.87 CHECKED BY: T O DATE: f 3 C:1ExcellTempfetest1HOP&S-DFuao i.xisjSheotl AGEOSERVER1Data DrivelSynthettcs12013 SYNTHETICS 118 - F&R - CAMPBELL51(L13118-03 CAMPBELLS DS•3.xls1Sheetl L13118-03.04 1216113 544 Braddock Avenue • East Pittsburgh, PA 15112 • 412-823-7600 • FAX 412-823-8999 • www.geotechnics.net PEEL AND SHEAR TEST RESULTS DESTRUCTIVE SEAM TESTING ASTM D 6392 CLIENT: CLIENT. PROJECT:` PROJECT NO.: LAB ID NO.: MATERIAL: SEAM TYPE: eotechnics FROEHLING & ROBERTSON,;INC.. CAMPBELL'S SOUP SUPPLY "B" FIELD EXPANSION L13118-03 L13118-03-05 60 MIL HDPE DOUBLE FUSION SAMPLE I.D.: DS-5 PEEL ADHESION INTEGRITY IN TESTING REPLICATE No. PEAK LOAD EPA BREAK CLASSIFICATION PEEL INCURSION (Ibs/in) CODE (%) OUTSIDE TRACK (WELD "A") 1 -. 130.3 SE1 <10 2 122.5 SE1 <10 3 124.0 SE1 <10 4 ' . 120.9 SE1 <10 5. 121.8 . SE1 <10 AVERAGE 'f 239 STD. DEV. 3.36 INSIDE TRACK (WELD "B") 1 124.7 SE1 <10 2 114.0 SE1 <10 3 111.1 SE1 <10 4 -113.1 SE1 <10 5 116.8 SE1 . <10 AVERAGE 115.9 STD. DEV.. 4.75 . BONDED SEAM (SHEAR) STRENGTH REPLICATE No. PEAK LOAD (Ibsen) EPA BREAK CLASSIFICATION CODE 1 145.8 SE1 2 154.7 SE1 3 149.9 SE1 4 144.6 SE1 5 150.6 SE1 AVERAGE 149.1 STD. DEV. 3.62 CHECKED BY I= U DATE: I G -13 C;1ExcehTemptales))HDP8S-DFusion.xtsj$tiest1 11GEOSERVERIData DrivelSyntheUes12013 SYNTHETtCS11_18 - F&R-CAMPBELLS1{L131 t8-03 CAMPBELLS DS-0,x's)Shaet1 113118-03-05 1216113 544 Braddock Avenue • East Pittsburgh, PA 15112 • 412-823-7600. • FAX 412-823-8999 • www.geotechnics.net PEEL AND SHEAR TEST RESULTS DESTRUCTIVE SEAM TESTING ASTM D 6392 CLIENT: CLIENT PROJECT: PROJECT NO.: LAB ID NO.: MATERIAL: SEAM TYPE: FROEHLING & ROBERTSON, INC. CAMPBELL'S SOUP SUPPLY "B" FIELD EXPANSION L13118-03 L13118-03-06 60 MIL HDPE DOUBLE FUSION SAMPLE I.D.: DS-6 PEEL ADHESION technics INTEGRITY IN TESTING TESTING REPLICATE No. PEAK LOAD EPA BREAK CLASSIFICATION PEEL INCURSION (Ibs/in) . . CODE (%) OUTSIDE TRACK (WELD A") 1 124.6 SE1 <10 2 138.7 SE1 <10 3 121.0 SE1 <10 4 127.7 .SE1 <10 5 132.2 SE1 <10 AVERAGE 128:8 STD. DEV. 6.15 • INSIDE TRACK :(WELD 'B"). 1 114.0 SE1 <10 2 124:0 SE1 <10 3 109.7 SE1 <10 4 116.0 SE1 <10 5 129.3 SE1 <10 AVERAGE ..118.6 STD. DEV. 7.08 BONDED SEAM (SHEAR) STRENGTH REPLICATE No. PEAK LOAD (Ibs/in) EPA BREAK CLASSIFICATION CODE 1 152.8 SE1 2 145.1 SE1 3 146.4 SE1 4 149.6 SE1 5 151.4 SE1 AVERAGE 149.1 STD. DEV. 2.92 CHECKED BY: 7• C:i DATE: ,'( a-' (3 C:tExeelfTemplatesl(HDP&S-DFuitcn.xls]Sheet1 11GEDSERVER\Data DitvelSynlhat cs12013 SYNTHETICS1118 - PEA- CAMP8ELLS4L13118-03 CAMPBELLS DS-5,xlsISheett' L13118-03-06 1216113 544 Braddock Avenue • East Pittsburgh, PA 15112 • 412-823-7600 • FAX 412-823-8999 • www.geotechnics.net PEEL AND SHEAR TEST RESULTS DESTRUCTIVE SEAM TESTING ASTM D 6392 eotechnics INTEGRITY IN TESTING CLIENT: FROEHLING & ROBERTSON, INC. CLIENT PROJECT: CAMPBELL'S SOUP SUPPLY "B" FIELD EXPANSION PROJECT NO.: L13118-03 LAB ID NO.: L13118-03-07 MATERIAL: 60 MIL HDPE SEAM TYPE: DOUBLE FUSION SAMPLE I.D.: DS-7 PEEL ADHESION REPLICATE No. PEAK LOAD (Ibs/in) EPA BREAK CLASSIFICATION CODE _ PEEL. INCURSION (%) OUTSIDE TRACK (WELD 'A") 1 121.5 SE1 <10 2 118.8 SE1 <10 3 115.9 SE1 <10 4 124.5 SE1 <10 5 126.0 SE1 <10 AVERAGE 121.3 STD. DEV. 3.68 INSIDE TRACK (WELD "B") 1 113.7 SE1 <10 2 114.2 SE1 <10 3 112.7 SE1 <10 4 122.0 SE1 <10 5 121.0 SE1 <10 AVERAGE 116.7 STD. DEV. 3.95 BONDED SEAM (SHEAR) STRENGTH REPLICATE No. PEAK LOAD (IbsIin) EPA BREAK CLASSIFICATION CODE 1 147.7 SE1 2 143.6 SE1 3 147.2 SE1 4 153.2 SE1 5 148.4 SE1 AVERAGE 148.0 STD. DEV.. 3.08 CHECKED BY: 110 DATE: I a- (o -( 3 CAExceaTemplales\ NOP&S•DFusion.xlejSheetl IIGEOSERVERIData DrivelSynthellcs12D13 SYNTHETICSN 18 - F&R - CAM.iPBELLSl L13118-03 CAMPBELLS DS-6.xlslSheetl L13118-03-07 12/6413 544 Braddock Avenue • East Pittsburgh, PA 15112 • 412-823-7600 • FAX 412-823.8999 • www.geotechnics.net PEEL AND SHEAR TEST RESULTS DESTRUCTIVE SEAM TESTING ASTM D 6392 CLIENT: CLIENT PROJECT: PROJECT NO.: LAB ID NO.: MATERIAL: SEAM TYPE: Gtechnics FROEHLING & ROBERTSON, INC. CAMPBELLS SOUP SUPPLY "B" FIELD EXPANSION L13118-03 L13118-03-08 60 MIL HDPE DOUBLE FUSION SAMPLE I.D.: DS-8 PEEL ADHESION INTEGRITY IN TESTING IN TESTING REPLICATE No. PEAK LOAD (Ibsen) EPA BREAK CLASSIFICATION CODE PEEL INCURSION (%) - OUTSIDE TRACK (WELD "A') . 1 115.3 SE1 <10 2 122.3 SE1 <10 3 122.3 SE1 <10 4 120.3 SE1 <10 5 . 118.8 SE1 <10 AVERAGE 119.8 STD. DEV. 2.61 INSIDE TRACK (WELD 'B") 1 107.4 SE1 <10 2 114.5 SE1 <10 3 120.0 SE1 <10 4 115.3 SE1 <10 5 • 118.6 SE1 <10 AVERAGE 115.2 STD. DEV. 4.38 BONDED SEAM (SHEAR) STRENGTH REPLICATE - No. PEAK LOAD (Ibs/in) EPA BREAK CLASSIFICATION CODE 1 149.4 SE1 2 150.4 SE1 3 150.0 SE1 4 153.8 SE1 5 150.2 SE1 AVERAGE 150.8 STD. DEV. 1.56 CHECKED BY: TO DATE: 101- - - (3 C:1ExcellTemplatesl(H DP&S-DFusan.xls]Sheel1 \1GEOSERVER1Data DrivelSynthetln12013 SYNTHETICS1118 - F&R - CAMPBELLS4(L13118-03 CAMPBELLS DS7:xds]Shee11 L13118-03-08 1216113 544 Braddock Avenue • East Pittsburgh, PA 15112 • 412-823-7600 • FAX 412-823-8999 • www.geotechnics.net PEEL AND SHEAR TEST RESULTS DESTRUCTIVE SEAM TESTING AVM 'D 6392 eotechnics INTEGRITY IN TESTING CLIENT: FROEHLING & ROBERTSON, INC.. CLIENT PROJECT: CAMPBELL'S SOUP SUPPLY "B" FIELD EXPANSION PROJECT NO.:.L13118-03 LAB ID NO.: L13118-03-09 MATERIAL: 60 MIL HDPE SEAM TYPE: DOUBLE FUSION SAMPLE I.D.: DS-9 PEEL ADHESION REPLICATE No. PEAK LOAD EPA BREAK CLASSIFICATION PEEL INCURSION (Ibs/in) CODE (%) OUTSIDE TRACK (WELD 'A") 1 124.0 SE1 <10 2 121.1 SE1 <10 3 121.4 SE1 <10 4 . 132.8 SE1 <10 5 122.2 SE1 <10 AVERAGE 124.3 STD. DEV. 4.37 INSIDE TRACK (WELD "B") 1 118.1 SE1 <10 2 117.8 SE1 <10 3 114.9 SE1 <10 4 121.7 SE1 <10 5 120.5 SE1 <10 AVERAGE 118.6 STD. DEV. 2.36 BONDED SEAM (SHEAR) STRENGTH REPLICATE No. PEAK LOAD (IbsTn) EPA BREAK CLASSIFICATION CODE 1 153.8 SE1 2 149.6 SE1 3» 151.3 SE1 4 150.5 SE1 5 _ 149.5 SE1 AVERAGE 150.9 STD. DEV. 1.57 CHECKED BY: 12-(_) DATE: /a - 6 ' (3 C:1ExcellTemplate5 DPBS•DFusion,xla]Sheel1 11GEOSERVERRData Drive1Synthetl s12013 SYNTHETICS1118 - F8R - CAMPBELLSI(L13118.03 CAMPBELLS DS-8.x{sjSheet1. L13118-03-09 1216113 544 Braddock Avenue • East Pittsburgh, PA 15112 • 412-823-7600 • FAX 412-823-8999 • www.geotechnics.net PEEL AND SHEAR TEST RESULTS DESTRUCTIVE SEAM TESTING ASTM D 6392 CLIENT: CLIENT PROJECT: PROJECT NO.:, LAB ID NO. MATERIAL: SEAM TYPE: 'eotechnics FROEHLING & ROBERTSON, INC. CAMPBELL'S SOUP SUPPLY "B" FIELD EXPANSION L1.3118-03 L13118-03-10 60 MIL HDPE DOUBLE FUSION SAMPLE I.D.: DS-10 PEEL ADHESION INTEGRITY IN TESTING REPLICATE No. PEAK LOAD EPA BREAK CLASSIFICATION PEEL INCURSION (Ibsen) CODE (%) OUTSIDE TRACK (WELD 'A` 1 126.4 SE1 <10 2 112.5 SE1 <10 3 122.7 SE1 <10 4 118.9 SE1 <10 5 125.2 SE1 <10 AVERAGE 121.1 STD. DEV. 5.02 INSIDE TRACK (WELD "B') 1 122.4 SE1 <10 2 115.5 SE1 <10 3 110.5 . SE1 <10 4 109.4 SE1 <10 5 120.9 SE1 <10 AVERAGE 115.7 STD. DEV. 5.27 BONDED SEAM (SHEAR) STRENGTH REPLICATE No. PEAK LOAD (Ibs/in) EPA BREAK CLASSIFICATION CODE 1 146.6 SE1 2 150.9 SE1 3 147.2 SE1 4 142.4 SE1 5 147.4 SE1 AVERAGE. 146.9 STD. DEV. 2.71 CHECKED BY: To DATE: ,' 6-13 C:1ExeeflTemplateslIHDP&S-DFuslon:xls[Sheet1 \%GEOSERVER1Data'DrivelSyntheticsl2O13 SYNTHETICSI118 - F8R - CAMPBELLSI[L13118-C3 CAMPBELLS DS•9.xlsjSheetl L13118.03-10 12/6/13 544 Braddock Avenue • East Pittsburgh, PA 15112 • 412-823-7600 • FAX 412-823-8999 • www.geotechnics.net PEEL AND SHEAR TEST RESULTS DESTRUCTIVE SEAM TESTING ASTM D 6392 eotechnics INTEGRITY IN TESTING CLIENT: FROEHLING & ROBERTSON, INC.: CLIENT PROJECT: CAMPBELL'S SOUP SUPPLY "B" FIELD EXPANSION PROJECT NO:: L13118-03 LAB ID NO.: L13118-03-11 MATERIAL: 60 MIL HDPE SEAM TYPE: DOUBLE FUSION SAMPLE I.D.: DS-11 PEEL ADHESION REPLICATE No. PEAK LOAD EPA BREAK CLASSIFICATION PEEL INCURSION (Ibs/in) CODE (%) OUTSIDE TRACK (WELD 'A") 1 122.0 SE1 <10 2 119.8 SE1 <10 3 121.2 SE1 <10 4 119.1 SE1 _ <10. 5-" 119.7 SE1 <.10 AVERAGE 120.4 STD. DEV. 107 INSIDE TRACK (WELD "B") 1• 123.5 SE1 <10 2 110.0 SE1 <10 3 106.0 SE1 <10 4 122.1 SE1 <10 5 .- 122.2 SE1 <10: AVERAGE 116.8 STD. DEV. 7.28 BONDED SEAM (SHEAR) STRENGTH REPLICATE No. PEAK LOAD (Ibs/in) EPA BREAK CLASSIFICATION CODE 1 144.2 SE1 2 149.6 SE1 3 147.6 SE1 4 145.4 SE1 5 146.9 SE1 AVERAGE 146.7 STD. DEV. 1.85 CHECKED BY: 116. DATE: 1"'-6)' (3 C:1Exeel TomplataallHDP&S-DFusion.xlsjSheet1 'BGEOSERVERIData DrivelSynthetics12013 SYNTHETICSt118 - F8R - CAMPBELLSI(L13118-03 CAMPBELLS DS-10.x1sISheetl L13118-03-11 1216/13 544 Braddock Avenue • East Pittsburgh, PA 15112 • 412-823-7600 • FAX 412-823-8999 • www.geotechnics.net PEEL AND SHEAR TEST RESULTS DESTRUCTIVE SEAM TESTING ASTM D 6392 CLIENT: CLIENT PROJECT: PROJECT NO.: LAB ID NO.: MATERIAL: SEAM TYPE: SAMPLE I.D.: eotechnics FROEHLING & ROBERTSON, INC. CAMPBELL'S SOUP SUPPLY "B" FIELD EXPANSION L13118-03 L13118-03-12 60 MIL HDPE DOUBLE FUSION DS-12 PEEL ADHESION INTEGRITY 1N TESTING REPLICATE No. PEAK LOAD EPA BREAK CLASSIFICATION PEEL INCURSION (IbsM) CODE (%) OUTSIDE TRACK (WELD "A") 1 119.4 SE1 <10 2 121.1 SE1 <10 3 123.2 SE1 <10 .4 115.0 •SE1 <10 5 118.3 SE1 <10 AVERAGE 119.4 STD. DEV. 2.75 INSIDE TRACK (WELD "B") 1 113.7 SE1 <10 2 120.2 SE1 <10 3 117.7 SE1 <10 4 126.5 SE1 <10 5 . 121.8 SE1 <10 AVERAGE 120.0 STD. DEV. 4.25 BONDED SEAM (SHEAR) STRENGTH REPLICATE No. PEAK LOAD (Ibs/in) EPA BREAK CLASSIFICATION CODE 1 141.6 SE1 2 148.7 SE1 3 144.9 SE1 4 145.2 SE1 5 146.1 SE1 AVERAGE 145.3 STD. DEV. 2.28 CHECKED BY: TO DATE: /ae 6 r- IT CAExee lTemplalest[HDPBS-DFusion.xlsISheat t 11GEOSERVER1Data DrivalSynthaUcM2013 SYNTHETICS\118 - F&R - CAMPBELLSI[L13118-03 CAMPBELLS DS-11,xisISheet1 L13110•03-12 1213J13 544 Braddock Avenue • East Pittsburgh, PA 15112 • 412-823-7600 • FAX 412-823-8999 • www.geotechnics.net PEEL AND SHEAR TEST RESULTS DESTRUCTIVE SEAM TESTING ASTM D 6392 CLIENT: CLIENT PROJECT: PROJECT NO.: LAB ID NO.: MATERIAL: SEAM TYPE: eotechnic'$ FROEHLING & ROBERTSON, INC. CAMPBELL'S SOUP SUPPLY "B" FIELD EXPANSION L13118-03 L13118-03-13 60 MIL HDPE DOUBLE FUSION SAMPLE I.D.: DS-13 PEEL ADHESION INTEGRITY IN TESTING REPLICATE No. PEAK LOAD (Ibs/in) EPA BREAK CLASSIFICATION CODE PEEL INCURSION (%) OUTSIDE TRACK (WELD 'A") 1 118.4 SE1 <10 2 121.9 SE1 <10 3 118.4 SE1 <10 4 117.0 SE1 <10 5 , 118.0. SE1 : <10 AVERAGE 1187 STD. DEV. 1.66 , . INSIDE TRACK (WELD "B") 1 109.4 SE1 <10 2 129.4 SE1 <10 3 112.7 SE1 <10 4 111.6 SE1 <10 5 119.7 SE1 <10 AVERAGE 116.E STD. DEV. 7.29 BONDED SEAM (SHEAR) STRENGTH REPLICATE No. PEAK LOAD (ibsrn) EPA BREAK CLASSIFICATION CODE 1 144.6 SE1 2 147.0 SE1 3 138.9 SE1 4 141.7 SE1 5 145.5 SE1. AVERAGE 143.5 STD. DEV. 2.89 CHECKED BY: TO DATE: / t7 C:IExcellTemplalesl[HDPBS-OFusion xls]Sheetl \1GEOSERVERIData DrivelSyntheUce12013 SYNTHETICS1116 - F&R - CAMPBELLSI[L13118-03 CAMPBELLS DS-12.xls1Sheett L13118-03-13 12013 544 Braddock Avenue • East Pittsburgh, PA 15112 • 412-823-7600 • FAX.412-823-8999 • www.geotechnics.net PEEL AND SHEAR TEST RESULTS DESTRUCTIVE SEAM TESTING ASTM D 6392 CLIENT: CLIENT PROJECT: PROJECT NO.: LAB ID NO.: MATERIAL: SEAM TYPE: eotechnics INTEGRITY IN TESTING FROEHLING & ROBERTSON, INC.. CAMPBELL'S SOUP SUPPLY "B" FIELD EXPANSION L13118-03 L13118-03-14 60 MIL HDPE DOUBLE FUSION SAMPLE 1.D.: DS-14 PEEL ADHESION REPLICATE No. PEAK LOAD EPA BREAK CLASSIFICATION PEEL INCURSION (Ibs/in) CODE (%) OUTSIDE TRACK (WELD "A") 1 119.8 SE1 <10 2 120.8 SE1 <10 3 119.9 SE1 <10 4 121.2 SE1 <10 5 117.5 SE1 <10 AVERAGE 119.8 STD. DEV. 1.28 INSIDE TRACK (WELD "B") 1 119.6 SE1 <10 2 121.7 SE1 <10 3 123.0 SE1 <10 4 117.7 SE1 <10 5 113.7 SE1 <10 AVERAGE 119.1 STD. DEV. 3.27 BONDED SEAM (SHEAR) STRENGTH REPLICATE No, PEAK LOAD (Ibs/in) EPA BREAK CLASSIFICATION CODE 1 149.6 SE1 2 151.4 SE1. 3 150.1 SE1 4 149.4 SE1 5. 148.7 SE1 AVERAGE 149.8 STD. DEV: 0.90 CHECKED BY: T d DATE: / a.- 6 - (3 CAExceRTemPjitest(HOP8S-13Fustan.xlslSheeN 1tGEOSERVER\Data DrivelSynthsllos12013 SYNTHETICS11.18 - F8R-CAMPBELLSllL13118O3 CAMPBELLS DS.13.xisJSheet1 L13118-03-14 1218113 544 Braddock Avenue • East Pittsburgh, PA 15112: • 412-823-7600 • FAX 412-823-8999 • www.geotechnics.net PEEL AND SHEAR TEST RESULTS DESTRUCTIVE SEAM TESTING ASTM l3 6392 CLIENT: CLIENT PROJECT: PROJECT NO.: LAB ID NO.: MATERIAL: SEAM TYPE: eotechnics FROEHLING & ROBERTSON,.INC. CAMPBELL'S SOUP SUPPLY "B" FIELD EXPANSION L13118-03 L13118-03-15 60 MIL HDPE DOUBLE FUSION SAMPLE I.D.: DS-15 PEEL ADHESION INTEGRITY IN TESTING REPLICATE No. PEAK LOAD EPA BREAK CLASSIFICATION PEEL INCURSION (Ibs/in) CODE (%) OUTSIDE TRACK (WELD "Al 1 122.8 SE1 <10 2 120.1 SE1 <10. 3 119.5 SE1 <10 4 114.0 SE1 <10 5 120.1 SE1 <10 AVERAGE 119.3 STD. DEV. 2.89 INSIDE TRACK (WELD "B") 1 130.6 SE1 <10 2 126.6 SE1 <10 3 130.6 SE1 <10 4 122.4 SE1 <10 5 122.3 SE1 <10 AVERAGE 126.5 STD. DEV. 3.69 BONDED SEAM (SHEAR) STRENGTH REPLICATE No. PEAK LOAD (Ibs/in) EPA BREAK CLASSIFICATION CODE 1 155.0 SE1 2 150.8 SE1 3 150.8 SE1 4 148.5 SE1 5 150.9 SE1 AVERAGE 151.2 STD. DEV. 2.10 CHECKED BY: j- d DATE: I - 12 C: Exce1lT.mplatasl(HDP&S-0Fusfon,xlsj5heet1 NGEOSERVERRData DrlvelSynthatics12013 SYNTHETICSl118 - FSR-CAMPBELLS\(L13118-03 CAMPBELLS DS-14;xlsjSheetl L13118-03.15 544 Braddock Avenue • East Pittsburgh, PA 15112 • 412-823-7600 • FAX 412-823-8999 • www.geotechnics.net PEEL AND SHEAR TEST RESULTS DESTRUCTIVE SEAM TESTING ASTM D 6392 CLIENT: CLIENT PROJECT: PROJECT NO.: LAB ID NO.: MATERIAL: SEAM TYPE: ea#echnics FROEHLING & ROBERTSON, INC. CAMPBELL'S SOUP SUPPLY "B" FIELD EXPANSION L13118-03 L13118-03-16 60 MIL HDPE DOUBLE FUSION SAMPLE I.D.: DS-16 PEEL ADHESION, INTEGRITY IN TESTING REPLICATE No. PEAK LOAD EPA BREAK CLASSIFICATION PEEL INCURSION (Ibs/in) CODE (%) OUTSIDE TRACK (WELD "A") 1 108.4 SE1 <10 2 107.5 SE1 <10 3 106.8 SE1 <10 4 112.2 SE1 <10 5 106.7. SE1 <10 AVERAGE 108.3 STD: DEV. 2.03 INSIDE TRACK (WELD "B') 1 130.3 SE1 <10 2 126.2 SE1 <10 3 114.6 SE1 <10 4 126.7 SE1 <10 5 107.5 SE1 <10 AVERAGE 121.1 STD. DEV. 8.59 BONDED SEAM (SHEAR)STRENGTH REPLICATE No. PEAK LOAD (Ibs/in) EPA BREAK CLASSIFICATION CODE 1 153.4 SE1 2 149.2 SE1 3 148.0 SE1 4 149.0 SE1 5 146.5 SE1 AVERAGE 149.2 STD. DEV. 2.30 CHECKED BY: 11--45 DATE: ) 6- l 3 C:1Excel1Templates11HOPES-DFuston xls1Sheet1 t1GEOSERVER1Data DrivelSynthe Ica12013 SYNTHETICS 118 • FER-CAMPBELLSV(113118-03 CAMPBELLS DS•15;xlsjSheefl L13118-03.16 12/6/13 544 Braddock Avenue • East Pittsburgh, PA 15112 • 412-823-7600 • FAX 412-823-8999 • www.geotechnics.net PEEL AND SHEAR TEST RESULTS DESTRUCTIVE SEAM TESTING ASTM D 6392 CLIENT: CLIENT PROJECT: PROJECT NO.: LAB ID NO.: MATERIAL: SEAM TYPE: eotechni.cs FROEHLING & ROBERTSON, INC.. CAMPBELL'S SOUP SUPPLY "B" FIELD EXPANSION L13118-03 L13118-03-17 60 MIL HDPE DOUBLE FUSION • SAMPLE I.D.: DS-17 PEEL ADHESION INTEGRITY IN TESTING REPLICATE No. PEAK LOAD EPA BREAK CLASSIFICATION PEEL INCURSION (lbs/in) CODE, .." (%) OUTSIDE TRACK (WELD 'A, 1 112.7 SE1 <10 2 119.6 SE1 <10 3 114.5 _. SE1 <10 4 115.2 SE1 <10 5 _ . 114.0 SE1 .: <10 AVERAGE 115.2 STD. DEV. 2:35 INSIDE TRACK (WELD .,,B, 1 1130 SE1` <10 2 114.9 SE1 <10 3 113.2 SE1 <10 4 108.3 SE1. <10 5 120.5 SE1 <10 AVERAGE 1140 STD. DEV. 3.93 BONDED SEAM (SHEAR) STRENGTH REPLICATE No.. PEAK . LOAD (Ibs/in). EPA BREAK CLASSIFICATION CODE 1 146.7. ' SE1 2 144.4 SE1 3 143.8 SE1 4 142.1 SE1 5 144:4 SE1 AVERAGE 144.3 STD. DEV. 1.47 CHECKED BY: 7 0 DATE: I c)-e- 6 1 CAExee0Tamplalea1HHOPES-DFusian.xle]Sheell 11GEOSERVERRData DrivelSynthe6c312013 SYNTHETICStl18 - FAR - CAMPBELLSI[L13118.03 CAMPBELLS DS-16.x13ISheet1 L13118-03-17 544 Braddock Avenue • East Pittsburgh, PA 15112 • 412-823-7600 • FAX 412-823-8999 www.geotechnics.net PEEL AND SHEAR TEST RESULTS gtechnics DESTRUCTIVE SEAM TESTING INTEGRITY IN TESTING ASTM D 6392 CLIENT: CLIENT PROJECT: PROJECT NO.: LAB ID NO.: MATERIAL: SEAM TYPE: FROEHLING & ROBERTSON, INC.. CAMPBELL'S SOUP SUPPLY "B" FIELD EXPANSION L13118-03 L13118-03-18 60 MIL HDPE DOUBLE FUSION SAMPLE I.D.: DS�18 PEEL ADHESION REPLICATE No. PEAK LOAD EPA BREAK CLASSIFICATION PEEL INCURSION (Ibsen) CODE (%) OUTSIDE TRACK (WELD "A") 1 116.7 SE1 <10 2 114.3 SE1 <10 3 135.3 SE1 <10 4 134.6 SE1 <10 5 138.0 SE1 <10 AVERAGE 127.8 STD. DEV. 10.12 INSIDE TRACK (WELD "B") 1 123.8 SE1 <10 2 114.7 SE1 <10 3 116.0 SE1 <10 4 113.4 SE1 <10 5 114.9 SE1 <10 AVERAGE 116.6 . STD. DEV. 3.71 BONDED SEAM (SHEAR) STRENGTH REPLICATE No. PEAK LOAD (Ibs/in) EPA BREAK CLASSIFICATION CODE 1 158.1 SE1 2 155.4 SE1 3 155.6 SE1 4 155.3 SE1 5 153.9 SE1 AVERAGE 155.7 STD. DEV. 1.36 CHECKED BY: PO DATE: , I a- — 6 - %3 C,1E ceetTempletesttHDPBS-DFuslon.xlsiSheet1 ItGEOSERVER1Data OrivalSynthatics12013 SYNTHETIC31118 - F&R - CAMPBELLSt{L13118.03 CAMPBELLS DS-17ads1Sheett L13118-03-18 12/6/13 544 Braddock Avenue • East Pittsburgh, PA 15112 • 412-823-7600 • FAX 412-823-8999 • www.geotechnics.net PEEL AND SHEAR TEST RESULTS DESTRUCTIVE SEAM TESTING ASTM D 6392 CLIENT: CLIENT PROJECT: PROJECT NO.: LAB ID NO.: MATERIAL: SEAM TYPE: eotechnics FROEHLING & ROBERTSON, INC. CAMPBELL'S SOUP SUPPLY "B" FIELD EXPANSION L13118-03 L13118-03-19 60 MIL HDPE DOUBLE FUSION SAMPLE I.D.: DS-19 PEEL ADHESION INTEGRITY 1N TESTING REPLICATE No. PEAK LOAD (Ibs/in) EPA BREAK CLASSIFICATION CODE PEEL INCURSION .. (%) OUTSIDE TRACK (WELD "A") 1 124.1 SE1 <10 2 127.0 SE1 <10 3 120.2 SE1 <10 4 124.6 SE1 <10 5 .121.2 SE1 <10 . AVERAGE 123.4 . STD. DEV. 2.45 INSIDE TRACK (WELD "B") 1 116.2 SE1 <10 2 117.1 SE1 <10 3 121.4 SE1 • <10 4 110.7 SE1 <10 5 115.6 SE1 _ <10 AVERAGE 116.2 STD. DEV. 3.42 BONDED SEAM (SHEAR) STRENGTH REPLICATE No. ,PEAK LOAD (Ibsen) . EPA BREAK CLASSIFICATION CODE 1 152.3 SE1 2 148.1 SE1 3 148.4 SE1 4 149.1 SE1 5 147.4 SE1 AVERAGE . 149.1 STD.: DEV. 1.71 CHECKED BY: J DATE: )d-_ %- / 3 CAExcertTempTatesl(HDPBs-DFueion, xlslSh eat1 11GEOSERVER1Data DiivrASynthetln12013 SYNTHETICSN 18 . F&R - CAMPBELLS%(L13118-03 CAMPBELLS DS•1B:xIeJShee11 L13118.03-19 544 Braddock Avenue • East Pittsburgh, PA 15112 • 412-823-7600 • FAX 412-823-8999 • www.geotechnics.net PEEL AND SHEAR TEST RESULTS DESTRUCTIVE SEAM TESTING ASTM D 6392 CLIENT: CLIENT PROJECT: PROJECT NO.: LAB ID NO.: MATERIAL: SEAM TYPE: FROEHLING & ROBERTSON, INC. CAMPBELL'S SOUP SUPPLY "B" FIELD EXPANSION L13118-03 L13118-03-20 60 MIL HDPE DOUBLE FUSION SAMPLE I.D.: DS-20 PEEL ADHESION technics INTEGRITY IN TESTING INTEGRITY IN TESTING REPLICATE No; PEAK LOAD EPA BREAK CLASSIFICATION PEEL INCURSION (lbs/in) • CODE (%) OUTSIDE TRACK (WELD 'A") 1 130.4 SE1 <10 2 134.2 SE1 <10 3 131.6 SE1 <10 4 133.1 SE1 <10 5 136.2 SE1 <10 AVERAGE 133.1 STD. DEV. 2.02 INSIDE TRACK (WELD "B") 1 120.2 SE1 <10 2 126.4 SE1 <10 3 129.6 SE1 <10 4 125.6 SE1 <10 5 129.4 SE1 <10 AVERAGE 126.2 STD. DEV. 3.41 BONDED SEAM (SHEAR) STRENGTH REPLICATE No. PEAK LOAD (Ibs/in) EPA BREAK CLASSIFICATION CODE 1 158.6 SE1 2 159.7 SE1 3 156.7 SE1 4 155.5 SE1 5 156.0 SE1 AVERAGE 157.3 STD. DEV. .. 1.60 CHECKED BY: T" 0 DATE: 1 " 1? C:tExcellTempfateel[HDPBS-DFusion xlsJSheet1 NGEOSERVER1Data DrivelSyntheticst2013 SYNTHETICS1118 - F8R - CAMPBELLSt(L13118-03 CAMPBELLS DS-19.xlejSheett L13118-03-20 1218113 544 Braddock Avenue • East Pittsburgh, PA 15112 • 412-823-7600 • FAX 412-823-8999 • www.geotechnics.net PEEL AND SHEAR TEST RESULTS DESTRUCTIVE SEAM TESTING ASTM D 6392 CLIENT: CLIENT PROJECT: PROJECT NO.: LAB ID NO.: MATERIAL: SEAM TYPE: eotechnics FROEHLING & ROBERTSON, INC. CAMPBELL'S SOUP SUPPLY "B" FIELD EXPANSION L13118-03 L13118-03-21 60 MIL HDPE DOUBLE FUSION SAMPLE I.D.: DS-21 PEEL ADHESION INTEGRITY IN TESTING REPLICATE No. PEAK LOAD EPA BREAK CLASSIFICATION PEEL INCURSION (Ibs/in) CODE (%) OUTSIDE TRACK (WELD "A") - 1 125.7 SE1 <10 2 114.1 SE1 <10 3 123.2 SE1 <10 4 124.4 SE1 <10 5 125.7 SE1 <10 AVERAGE 122.6 STD. DEV. 4.36 INSIDE TRACK (WELD "B") 1 .116.7 SE1 <10 2 127.4 ... SE1 <10 3 117.7 SE1 <10 4 116.1 SE1 <10 5 117.0 SE1 <10 AVERAGE' 119.0 STD. DEV. 4.24 BONDED SEAM (SHEAR) STRENGTH REPLICATE No.. PEAK LOAD (Ibslin) EPA BREAK CLASSIFICATION CODE 1 146.2 SE1 2 142.4 SE1 3 142.9 SE1 4 144.9 SE1 5 . 144.3 SE1 AVERAGE 144.1 STD. DEV. 1.37 CHECKED BY: 5s' c. DATE: I a- - 6— I ? C:1ExcellTempletesl(HDPSS DFusianits}Sheatl 11GEOSERVER\Dala DrivelSynthelk512013 SYNTHETICS1118 - FBA - CAMPBELLSI(L13118-03 CAMPBELLS DS-20.xls1SheeU L'13118-03-21 '1218113 544 Braddock Avenue • East Pittsburgh, PA 15112 • 412-823-7600 • FAX 412-823-8999 • www.geotechnics.net PEEL AND SHEAR TEST. RESULTS DESTRUCTIVE SEAM TESTING ASTM D 6392 CLIENT: CLIENT PROJECT: PROJECT NO.: LAB ID NO.: MATERIAL: SEAM TYPE: FROEHLING. & ROBERTSON, INC. CAMPBELL'S SOUP SUPPLY "B" FIELD EXPANSION L13118-03 L13118-03-22 60 MIL HDPE DOUBLE FUSION SAMPLE I.D.: DS-22 PEEL ADHESION technics INTEGRITY IN TESTING INTEGRITY IN TESTING REPLICATE No. PEAK LOAD (Ibs/in) EPA BREAK CLASSIFICATION CODE PEEL INCURSION (%) OUTSIDE TRACK (WELD "A") 1 120.8 SE1 <10 2 120.3 SE1 <10 3 118.9 SE1 <10 4 120.0 SE1 <10 5 124:6 SE1 <10 • AVERAGE 120.9 STD. DEV. 1.94 INSIDE TRACK (WELD "B") 1 119.9 SE1 <10 2 119.8 SE1 <10 3 113.7 SE1 <10 4 119.4 SE1 <10 5 115.8 SE1 <10 AVERAGE 117.7 - STD. DEV. 2.52 BONDED SEAM (SHEAR) STRENGTH REPLICATE No. PEAK LOAD (Ibs/in) EPA BREAK CLASSIFICATION CODE 1 147.0 SE1 2 143.9 SE1 3 143.9 SE1 4 142.5 SE1 5 143.6 SE1 AVERAGE 144.2 STD. DEV. 1.50 CHECKED BY: DATE: (- 12 CAExceATemplateM[HDPBS-0FuslonxlsiShaN1 1tGE0SERVER10ata DrivetSynthetJcs12013 SYNTHETICS1118 - F&R - CAMPBELLSI(L13118-03 CAMPBELLS DS-21.xis]Sheet1 L13116.03-22 12/6/13 544 Braddock. Avenue • East Pittsburgh, PA 15112 • 412-823-7600 • FAX 412-823-8999 • www.geotechnics.net PEEL AND SHEAR TEST RESULTS DESTRUCTIVE SEAM TESTING ASTM D 6392 eotechnics INTEGRITY IN TESTING CLIENT:. FROEF;ILING & ROBERTSON, INC. CLIENT PROJECT: CAMPBELL'S SOUP SUPPLY "B" FIELD EXPANSION PROJECT NO,;. L1.3118-03 LAB ID NO.' L13118-03-23 MATERIAL: 60 MIL HDPE SEAM TYPE:, DOUBLE FUSION SAMPLE I.D.: DS-23 PEEL ADHESION REPLICATE . No. PEAK LOAD EPA BREAK CLASSIFICATION PEEL INCURSION (lbs/in) CODE (%) OUTSIDE TRACK (WELD `A") 1 129.2 SE1 <10 2 129.3 SE1 <10 3 119.9 SE1 <10 4 129.4 SE1 <10 5 127.2 SE1 <10 AVERAGE 127.0 STD. DEV. 3.64 INSIDE TRACK (WELD "B") 1 124.2 SE1 <10 2 127.9 SE1 <10 3 127.5 SE1 <10 4 129.5 SE1 <10 5 127.6 SE1 <10 AVERAGE 127.3 STD. DEV. 1.73 BONDED SEAM (SHEAR) STRENGTH REPLICATE No. PEAK LOAD (Ibs/in) EPA BREAK CLASSIFICATION CODE 1 145.3 SE1 2 148.2 SE1 3 144.4 SE1 4 145.9 SE1 5 143.6 SE1 AVERAGE 145.5 STD. DEV. 1.57 CHECKED BY: 12 O DATE: is -6 r i3 C:1ExcellTemplatesl[HDP&$-DFusianxs]Sheet 1 11GEOSERVERIOata DrivelSynthaticsU 13 SYNTHETICS1118 . F8R - CAMPBELLSI(L13118-03 CAMPBELLS DS-22.xls)Shaetl L13118-03-23 1218113 544 Braddock Avenue • East Pittsburgh, PA 15112 • 412-823-7600 • FAX 412-823-8999 • www.geotechnics.net PEEL AND SHEAR TEST RESULTS . DESTRUCTIVE SEAM TESTING ASTM D 6392 CLIENT: CLIENT PROJECT: PROJECT NO.: LAB ID NO.: MATERIAL: SEAM TYPE: Gtechnics FROEHLING & ROBERTSON, INC.. CAMPBELL'S SOUP SUPPLY "B" FIELD EXPANSION L13118-03 L13118-03-24 60 MIL HDPE DOUBLE FUSION SAMPLE I.D.: DS-24 PEEL ADHESION INTEGRITY IN TESTING INTEGRITY IN REPLICATE No. PEAK LOAD (Ibs/in) EPA BREAK CLASSIFICATION CODE PEEL INCURSION (%), OUTSIDE TRACK (WELD "Al 1 112.0 SE1 <10 2 108.9 SE1 <10 3 111.4 SE1 <10 4 106.9 SE1 <10 5 113.3 SE1 <10 AVERAGE 110.5 STD. DEV: 2.30 INSIDE TRACK (WELD "B") 1 . -119.0 SE1 <10 2 116.9 SE1 <10 3 ' 1'12.9 SE1 <10 4 111.8 SE1 <10 5 111.9 SE1 <10 AVERAGE 114.5 • STD. DEV. 2.92 BONDED SEAM•(SHEAR) STRENGTH REPLICATE No. PEAK LOAD (Ibs/in) EPA BREAK CLASSIFICATION CODE 1 153.3 SE1 2 157.0 SE1 3 153.5 SE1 4 152.9 SE1 5 _ 153.9 SE1 AVERAGE 154.1 STD. DEV. 1.48 CHECKED BY: TO DATE: Ia - ,-/3 C:1ExcellTemplatesljHDP&S-DFusianxlsIShe et1 t GEOSERVER1Data DridelSyntheUcs12013 SYNTHETICS111 B - F&R - CAMPBELLSI[L13118-03 CAMPBELLS DS-23 xIe]Sheett L13118-03-24 12t8/13 544 Braddock Avenue • East Pittsburgh, PA 15112 • 412-823-7600 • FAX 412-823-8999 • www.geotechnics.net PEEL AND SHEAR TEST RESULTS DESTRUCTIVE SEAM TESTING ASTM D 6392 CLIENT: CLIENT PROJECT: PROJECT NO.: LAB ID NO.: MATERIAL: SEAM TYPE: 5::itechnics FROEHLING & ROBERTSON, INC. CAMPBELL'S SOUP SUPPLY "B" FIELD EXPANSION L13118-03 L13118-03-25 60 MIL HDPE DOUBLE FUSION SAMPLE I.D.: DS-25 PEEL ADHESION INTEGRITY IN TESTING 1N TESTING REPLICATE No. PEAK LOAD EPA BREAK CLASSIFICATION PEEL INCURSION (Ibs/in) CODE (%) OUTSIDE TRACK (WELD. "A") 1 118.5 SE1 <10 2 120.2 SE1 <10 3 127.4 SE1 <10 4 121.4 SE1 <10 5 119.9 SE1 <10 AVERAGE 121.5 STD. DEV. 3.10 INSIDE TRACK (WELD "B') 1 125.6 SE1 _ <10 2 113.6 SE1 <10 3 128.8 SE1 <10 4 123.4 SE1 <10 5 115.6 SE1 <10 AVERAGE 121.4 STD. DEV. 5.85 BONDED SEAM (SHEAR) STRENGTH REPLICATE No. PEAK LOAD (Ibslin) EPA BREAK CLASSIFICATION CODE 1 155.1 SE1 2 151.2 SE1 3 150.8 SE1 4 151.8 SE1 5 150.9 SE1 AVERAGE 152.0 STD. DEV. 1.61 CHECKED BY: 0 '-b DATE I a' G (3 C:1Excet%Teaylat®s1(HDP&S-DFusionxls1Sheet1 11GEOSERVER1Date DiivelSynthetice12013 SYNTHETICS1118 - F&R - CAMPBELLST.13118.O CAMPBELLS DS-24.xIsiShee11 L13118-03-25 121B113 544 Braddock Avenue • East Pittsburgh, PA 15112 • 412-823-7600 • FAX 412-823-8999 • www.geotechnics.net PEEL AND SHEAR TEST RESULTS DESTRUCTIVE SEAM TESTING ASTM D 8392 eotechnics INTEGRITY IN TESTING CLIENT: FROEHLING & ROBERTSON, INC. CLIENT PROJECT: CAMPBELL'S SOUP SUPPLY "B" FIELD EXPANSION PROJECT NO.: L13118-03 LAB ID NO.: L13118-03-26 MATERIAL: 60 MIL HDPE SEAM TYPE: DOUBLE FUSION SAMPLE I.D.: DS-26 PEEL ADHESION REPLICATE No. PEAK LOAD (Ibs/in) EPA BREAK CLASSIFICATION CODE PEEL INCURSION. (%) OUTSIDE TRACK (WELD "A") 1 118.9 SE1 <10 2 121.4 SE1 <10 3 121.5 SE1 <10 4 123.6 SE1 <10 5 122.1 SE1 <10 AVERAGE 121.5 STD. DEV. 1.52 INSIDE TRACK (WELD 'F) 1 113.0 SE1 <10 2 117.6 SE1 <10 3 114.6 SE1 <10 4 115.7 SE1 <10 5 123.7 SE1 <10 AVERAGE 116.9 STD. DEV. 3.71 BONDED SEAM (SHEAR) STRENGTH REPLICATE No. PEAK LOAD (ibs/in) EPA BREAK • CLASSIFICATION CODE 1 144.9 SE1 2 145.6 SE1 3 145.7 ` SE1 4 143.9 SE1 5 144.6 SE1 AVERAGE 144.9 STD. DEV. 0.67 CHECKED BY: TO DATE: f a'6=(3 C:IExcellTemplaleel[HDP&S-DFusion.x(.q]Sheet1 HGEOSERVER1Data Drive4Synlheli412013 SSYNTHET1CS1118., F&R F CAMPBELLSI(L13118.03 CAMPBELF.S DS-25,xfsjSheell L13118-03-26 1216113 544 Braddock Avenue • East Pittsburgh, PA 15112 • 412-823-7600 • FAX 412-823-8999 • www.geotechnics.net PEEL AND SHEAR TEST RESULTS DESTRUCTIVE SEAM TESTING ASTM D 6392 CLIENT: CLIENT PROJECT: PROJECT NO.: LAB ID NO.: MATERIAL: SEAM TYPE: eo echnics FROEHLING & ROBERTSON, INC. CAMPBELL'S SOUP SUPPLY "B" FIELD EXPANSION L13118-03 L13118-03-27 60 MIL HDPE DOUBLE FUSION SAMPLE I.D.: DS-27 PEEL ADHESION INTEGRITY IN TESTING INTEGRITY IN TESTING REPLICATE No. PEAK LOAD (Ibs/in) EPA BREAK CLASSIFICATION CODE PEEL INCURSION (%) • OUTSIDE TRACK (WELD "A") 1 117.6 SE1 <10 2 116.0 SE1 <10 3 120.1 SE1 <10 4 121.3 SE1 <10 5 . 115.8 SE1 <10 AVERAGE 118.2 STD. DEV. 2.20 INSIDE TRACK (WELD "B") 1 117.0 SE1 <10 2 114.1 SE1 <10 3 114.8 SE1 <10 4 112.7 SE1_ <10 5 114.2 SE1 <10 AVERAGE 114.6 STD. DEV. 1.40 BONDED SEAM (SHEAR) STRENGTH REPLICATE No. PEAK LOAD (Ibs/in) EPA BREAK CLASSIFICATION CODE 1 140.0 SE1 2 148.7 SE1 3 145.7 SE1 4 137.8 SE1 5 141.4 SE1 AVERAGE 142.7 STD. DEV. 3.95 CHECKED BY: TO DATE: /a-- % - (3 C:lExcellTemptetesljHDP&S-DFusion xls1Sheet1 11GEOSERVERIData DrlvelSynthet cs12013 SYNTHETICSi118 - F&R - CAMPBELLS7(L1311 8-03 CAMPBELLS DS-26.x!e)Sheetl L13118-03-27 12/6113 544 Braddock Avenue • East Pittsburgh, PA 15112 • 412-823-7600 • FAX 412-823-8999 • www.geotechnics.net PEEL AND SHEAR TEST RESULTS DESTRUCTIVE SEAM TESTING ASTM D 6392 CLIENT: CLIENT PROJECT: PROJECT NO.: LAB ID NO.: MATERIAL: SEAM TYPE: §technics FROEHLING & ROBERTSON, INC. CAMPBELL'S SOUP SUPPLY "B" FIELD EXPANSION L13118-03 L13118-03-28 60 MIL HDPE DOUBLE FUSION SAMPLE I.D.: DS-28 PEEL ADHESION INTEG111iY ENTE511NO INTEGRITY TESTING REPLICATE No. PEAK LOAD EPA BREAK CLASSIFICATION PEEL INCURSION (Ibslin) CODE (%) OUTSIDE TRACK (WELD "A') 1 126.6 SE1 <10 2 116.8 SE1 <10 3 112.9 SE1 <10 4 123.3 SE1 <10 5 114.9 SE1 <10 AVERAGE 1189 STD. DEV. 5.20 INSIDE TRACK (WELD "B") 1 130.7 SE1 <10 2 114.8 SE1 <10 3 128.8 SE1 <10 4 111.8 SE1 <10 5 . 114.0 SE1 <10 AVERAGE 120.0 STD. DEV. 8:03 BONDED SEAM (SHEAR) STRENGTH REPLICATE No. PEAK LOAD (Ibslin) EPA BREAK CLASSIFICATION CODE 1 155.0 SE1 2 151.8 SE1 3 151.4 SE1 4 151.9 SE1 5 151.3 SE1 AVERAGE 152.3 STD. DEV. 1.38 CHECKED BY: T' U DATE: I a- 6 " 0 C:tExcellTemplatesl(HOP&S-D Fuslon.xlsjSheet1 11GEOSERVER1Data DrlvalSynthetics12013 SYNTHETICS1118 - F&R - CAMPBELLS4L13118-03 CAMPBELLS DS•27.xls)Sheetl L13118-03-28 12/8113 544 Braddock Avenue • East Pittsburgh, PA 15112 • 412-823-7600 • FAX 412-823.8999 • www.geotechnics.net PEEL AND SHEAR TEST RESULTS DESTRUCTIVE SEAM TESTING ASTM D 6392 CLIENT: CLIENT PROJECT: PROJECT NO.: LAB ID NO.: MATERIAL: SEAM TYPE: eotechnics FROEHLING & ROBERTSON, INC. CAMPBELL'S SOUP SUPPLY "B" FIELD EXPANSION L13118-03 L13118-03-29 60 MIL HDPE DOUBLE FUSION SAMPLE I.D.: DS-29 PEEL ADHESION INTEGRITY IN TESTING REPLICATE No. PEAK LOAD EPA BREAK CLASSIFICATION PEEL INCURSION (IbsTn) CODE . (%) OUTSIDE TRACK (WELD "A") 1 118.8 SE1 <10 2 114.3 SE1 <10 3 123.3 SE1 <10 4 111.5 SE1 <10 5 118.3 SE1 .. <10 AVERAGE 117.2 STD. DEV. 4.05 INSIDE TRACK (WELD "B'9 1 118.0 SE1 <10 2 118.6 SE1 <10 3 127.5 SE1 <10 4 120.9 SE1 <10 5 115.5 SE1 <10 AVERAGE 120.1 STD. DEV. 4.08 BONDED SEAM (SHEAR) STRENGTH REPLICATE No. PEAK LOAD (Ibs/in) EPA BREAK CLASSIFICATION CODE 1 153.7 SE1 2 157.7 SE1 3 152.8 SE1 4 154.3 SE1 5 152.6 SE1 AVERAGE 154.2 STD. DEV. . 1.85 CHECKED BY: 3 DATE: -12 CAExceilTemp Ielesl(HDPBS-DFOlonxlnlSheot 1 11GEOSERVER1Date DrivelSyntheIIc 2D13 SYNTHETICS%118 -F&R - CAMPB, LLS1IL13118-03 CAMPBELLS DS-28.x1sISheell L13118-03-29 12/8113 544 Braddock Avenue • East Pittsburgh, PA 15112 • 412-823-7600 • FAX 412-823-8999 • www.geotechnics.net PEEL AND SHEAR TEST RESULTS DESTRUCTIVE SEAM TESTING ASTM D 6392 CLIENT: CLIENT PROJECT: PROJECT NO.: LAB ID NO.: MATERIAL: SEAM TYPE: GINTEGRITY IN TESTING eotechnics FROEHLING & ROBERTSON, INC. CAMPBELL'S SOUP SUPPLY "B" FIELD EXPANSION L13118-03 L13118-03-30 60 MIL HDPE DOUBLE FUSION SAMPLE I.D.: DS-30 PEEL ADHESION REPLICATE No. PEAK LOAD EPA BREAK CLASSIFICATION PEEL INCURSION (Ills/in) CODE (%) OUTSIDE TRACK (WELD "Al 1 119.0 SE1 <10 2 120.8 SE1 <10 3 116.4 SE1 <10 4 117.5 SE1 <10 5 114.3 SE1 <10 AVERAGE 117.6 STD. DEV. - 2.22 INSIDE TRACK (WELD "B") 1 115.4 SE1 <10 2 110.0 SE1 <10 3 119.7 SE1 <10 4 107.0 SE1 <10 5 105.6 SE1 <10 AVERAGE 111.5 STD. DEV. 5.29 BONDED SEAM (SHEAR) STRENGTH REPLICATE No. PEAK LOAD (IbsM) EPA BREAK CLASSIFICATION CODE 1 141.4 SE1 2 142.7 SE1 3 142.0 SE1 4 143.9 SE1 5 146.5 SE1 AVERAGE 143.3 STD. DEV. 1.80 CHECKED BY: J'd DATE: 2?-6-3 C:lExcellT3mplatea11HDP8S-OFutonxlsISheetl \1GEOSERVERIData Drtvel5ynthaticsl2013 SYNTHETICS1118 - F&R- CAMPBELLS4L13118-03 CAMPBELLS DS-29 xlsjSheet1 L13118-03-30 1216113 544 Braddock Avenue • East Pittsburgh, PA 15112 • 412-823-7600 • FAX 412-823-8999 • www.geotechnics.net PEEL AND SHEAR TEST RESULTS DESTRUCTIVE SEAM TESTING ASTM D 6392 CLIENT: CLIENT PROJECT: PROJECT NO.: LAB ID NO.: MATERIAL: SEAM TYPE: eotechnics FROEHLING & ROBERTSON, INC. CAMPBELL'S SOUP SUPPLY "B" FIELD EXPANSION L13118-03 L13118-03-31 60 MIL HDPE DOUBLE FUSION SAMPLE I.D.: DS-31 PEEL ADHESION INTEGRITY IN TESTING REPLICATE No. PEAK LOAD EPA BREAK CLASSIFICATION PEEL INCURSION (Ibs/in) CODE (%) OUTSIDE TRACK (WELD "A") 1 122.8 SE1 <10 2 119.5 SE1 <10 3 127.0 SE1 <10 4 118.4 SE1 <10 5 121.6 SE1 <10 AVERAGE • 121.9 STD. DEV. 3.00 INSIDE TRACK (WELD "B") 1 106.7 SE1 <10 2 111.6 SE1 <10 3 113.5, SE1 <10 4 113.9 SE1 <10 5 111.4 SE1 <10 AVERAGE 111.4 STD. DEV. 2.56 BONDED SEAM (SHEAR) STRENGTH REPLICATE No. PEAK LOAD . (Ibs/in) EPA BREAK CLASSIFICATION CODE 1 151.4 SE1 2 147.9 SE1 3 149.2 SE1 4 148.2 SE1 5 148.3 SE1 AVERAGE 149.0 STD. DEV. 1.28 CHECKED BY: To DATE: / a ' 6-(3 C:1Exceh7emplalesINDPBS-DFusbn.xLsjSheel l HGEOSERVER1Dala DrivelSynlheUcs12013 SYNTHETICS1118 - F&R - CAMPBELLS4L1311B-03 CAMPBELLS DS-30.xl8)Shaa 1 L13118-03-31 12f8113 544 Braddock Avenue • East Pittsburgh, PA 15112 • 412-823-7600 • FAX 412-823-8999 • www.geotechnics.net 1 PEEL AND'SHEAR TEST RESULTS DESTRUCTIVE SEAM TESTING ASTM D 6392 GecIte®technics INTEGRITY IN TESTING CLIENT: FROEHUNG & ROBERTSON, INC., CLIENT PROJECT: CAMPBELL'S SOUP SUPPLY "B" FIELD EXPANSION PROJECT NO.: L13118-03 LAB ID NO.: L13118-03-32 MATERIAL: 60 MIL HDPE SEAM TYPE: DOUBLE FUSION SAMPLE I.D.: DS-32 PEEL ADHESION REPLICATE No. PEAK LOAD EPA BREAK CLASSIFICATION PEEL INCURSION (Ibs/in) CODE (%) OUTSIDE TRACK (WELD "A") 1 126.6 SE1 <10 2 128.9 SE1 <10 3 113.0 SE1 <10 4 109.3 SE1 . <10 5 126.7 SE1 <10 AVERAGE 120.9 STD. DEV. 8.09 INSIDE TRACK (WELD "B") 1 129.3 SE1 <10 2 119.7 SE1 <10 3 - 124.7 SE1 <10 4 110.5 SE1 <10 5 122.4 SE1 <10 AVERAGE 121.3 STD. DEV. 6.26 BONDED SEAM (SHEAR) STRENGTH REPLICATE No. PEAK LOAD (Ibs/in) EPA BREAK CLASSIFICATION CODE 1 158.3 SE1 2 154.1 SE1 3 155.5 SE1 4 153.8 SE1 5 152.9 SE1 AVERAGE 154.9 STD. DEV. 1.89 CHECKED BY: To DATE: job- • - 13 C:1EzcellTempletesINDPBS-DFus:orulejSti cell 11GEOSERVER1Date DrlvelSynlhetics12013 SYNTHETICS1116 - F8R - CAMPBELLSl L13118-03 CAMPBELLS DS 1.xls)Sheet1 L13118-03-32 121 /13 544 Braddock Avenue • East Pittsburgh, PA 15112 • 412-823-7600 • FAX 412-823-8999 • www,geotechnics.net PEEL AND SHEAR TEST RESULTS DESTRUCTIVE SEAM TESTING ASTM D 6392 CLIENT: CLIENT PROJECT: PROJECT NO.: LAB ID NO.: MATERIAL: SEAM TYPE: gtechnics INTEGRITY IN TESTING FROEHLING & ROBERTSON, INC.: CAMPBELL'S SOUP SUPPLY "B" FIELD EXPANSION L13118-04 L13118-04-01 60 MIL HDPE DOUBLE FUSION SAMPLE I.D.: DS-33 PEEL ADHESION REPLICATE No. PEAK LOAD EPA BREAK CLASSIFICATION PEEL INCURSION (Ibs/in) CODE (%) OUTSIDE TRACK (WELD "A") 1 110.7 SE1 <10 2 120.9 SE1 <10 3 113.2 SE1 <10 4 120.0 SE1 <10 5 119.7 SE1 <10 AVERAGE 116.9 STD. DEV. 4.14 INSIDE TRACK (WELD "B") 1 103.0 SE1 <10 2 125.7 SE1 <10 3 119.6 SE1 <10 4 104.0 SE1 <10 5 107.5 SE1 <10 AVERAGE 112.0 STD. DEV. 9.06 BONDED SEAM (SHEAR) STRENGTH REPLICATE No. PEAK LOAD (Ibslin) EPA BREAK CLASSIFICATION CODE 1 152.3 SE1 2 154.7 SE1 3 153.8 SE1 4 154.6 SE1 5 157.8 SE1 AVERAGE 154.6 STD. DEV. ' 1.80 CHECKED BY: �.J1 DATE: 13-' 1 F43 C:tExceRTemplatas1[HDPBS•DFusian, x1sJSheetl 11GEDSERVERlDataDrivelSynthelics12013 SYNTHETICS1118-F&R-CAMPP?lI '71;10.Od, Al PEI LL.i US-a:,xls1Sheet1 L13118-04.01 12/18113 544 Braddock Avenue • East Pittsburgh, PA 15112 • 412-823-7600 • FAX 412-823-8999 • www.geotechnics.net PEEL AND SHEAR TEST RESULTS DESTRUCTIVE SEAM TESTING ASTM D 6392 CLIENT: CLIENT PROJECT: PROJECT NO.: LAB ID NO.: MATERIAL: SEAM TYPE: eotechnics INTEGRITY IN TESTING FROEHLING;& ROBERTSON, INC. CAMPBELL'S SOUP SUPPLY "B" FIELD EXPANSION L13118-04 L13118-04-02 60'MIL HDPE DOUBLE FUSION SAMPLE I.D.: DS-34 PEEL ADHESION REPLICATE No. PEAK LOAD (Ibs/in) EPA BREAK CLASSIFICATION CODE PEEL INCURSION (%) OUTSIDE TRACK (WELD "A") 1 117.5 SE1 <10 2 115.1 SE1 <10 3 113.6 SE1 <10 4 118.2 SE1 <10 •: 5 114.6 SE1 <10 AVERAGE 115.8 STD. DEV. 1.76 INSIDE TRACK (WELD "B") 1 128.9 SE1 <10 2 • 125.8 ` SE1 <10 3 124.9 - SE1 <10 4 116.5 SE1 <10 5 119.0 __ SE1 <10 AVERAGE 123.0 STD. DEV. 4.57 BONDED SEAM (SHEAR) STRENGTH REPLICATE No. PEAK LOAD (Ibs/in) EPA BREAK CLASSIFICATION CODE 1 159.3 SE1 2 154.5 SE1 3 155.9 SE1 4 155.0 SE1 5 155.1 SE1 AVERAGE 156.0 STD. DEV. 1.73 CHECKED BY: ii31C- DATE: ia--1 g^ 1-1, C.\ExcellTemplatesgHDPBS-DFus an,zlslSheet1 11GEOSERVER\Data DriveVSynthetics12013 SYNTHETICS1110 - FAR - CAMPBELLS(L13118-04 CAMPBELLS DS-34adsISheet1 L13118-04-02 12/18/13 544 Braddock Avenue • East Pittsburgh, PA 15112 • 412-823-7600 • FAX 412-823-8999 • www.geotechnics.net PEEL AND SHEAR TEST RESULTS DESTRUCTIVE SEAM TESTING ASTM D 6392 CLIENT: CLIENT PROJECT: PROJECT NO.: LAB ID NO.: MATERIAL: SEAM TYPE: eotechnics INTEGRITY IN TESTING FROEHLING & ROBERTSON, INC. CAMPBELL'S SOUP SUPPLY "B" FIELD EXPANSION L13118-04 L13118-04-03 60 MIL HDPE DOUBLE FUSION SAMPLE I.D.: DS-35 PEEL ADHESION REPLICATE No. PEAK LOAD (Ibsen) EPA BREAK CLASSIFICATION CODE - PEEL INCURSION (%) OUTSIDE TRACK (WELD "A") 1. : 118.2 SE1 <10 2 111.7 SE1 <10 3 110.5 SE1 <10 4 119.6 SE1 <10 5 124.4 SE1 <10 AVERAGE 116.9 STD. DEV. 5.16 INSIDE TRACK (WELD "Bs') 1 117.5 SE1 <10 2 118.1 SE1 <10 3 131.3 SE1 <10 4 114.6 SE1 <10 5 115.1 SE1 <10 AVERAGE 119.3 STD. DEV. 6.14 BONDED SEAM (SHEAR) STRENGTH REPLICATE No. PEAK LOAD (Ibs/in) EPA BREAK CLASSIFICATION CODE 1 158.9 SE1 2 157.2 SE1 3 158.2 SE1 4 158.2 SE1 5 159.1 SE1 AVERAGE 158.3 STD. DEV. 0.67 CHECKED BY: Bf DATE: 0-'t sH3 C:1Exce3Templalesl(HOP8S-DFuslm xlelsheeti 11GEOSERVER1Data OrivelSyntheljcs12013 SYNTHETICSl118 - F&R - CAMPBELLS4L13118-04 CAMP.BELLS DS-35.xls]Shaeli L13118-04-03 12/18/13 544 Braddock Avenue • East Pittsburgh, PA 15112 • 412-823-7600 • FAX 412-823-8999 • www.geotechnics.net PEEL AND SHEAR TEST RESULTS DESTRUCTIVE SEAM TESTING ASTM D 6392 CLIENT: CLIENT PROJECT: PROJECT NO.: LAB ID NO.: MATERIAL: SEAM TYPE: Geotechnics RI lNTEG TY IN TESTING FROEHLING & ROBERTSON, INC. CAMPBELL'S SOUP SUPPLY "B" FIELD EXPANSION L13118-04 L13118-04-04 60 MIL HDPE DOUBLE FUSION SAMPLE I.D.: DS-36 PEEL ADHESION REPLICATE No. , PEAK LOAD (Ibs/in) EPA BREAK CLASSIFICATION CODE PEEL INCURSION (%) OUTSIDE TRACK (WELD "A") 1 126.4 SE1 <10 2 121.2 SE1 <10 3 125.4 SE1 <10 4 129.6 SE1 <10 5 1139.0 SE1 <10 AVERAGE 128.3 .. STD. DEV. .....5.98 . INSIDE TRACK (WELD "B") 1 133.6 SE1 <10 2 114.0 SE1 <10 3 113.0 SE1 <1-0 4 113.6 SE1 <10 5 119.5 SE1 <10 AVERAGE 118:7 STD. DEV. 7.79 BONDED SEAM (SHEAR) STRENGTH REPLICATE No. PEAK LOAD (Ibs/in) EPA BREAK CLASSIFICATION CODE 1 158.9 SE1 2 154.5 SE1 3 152.8 SE1 4 153.7 SE1 5 154.3 SE1 AVERAGE 154.8 STD. DEV. _ 2.11 CHECKED BY E DATE: 1)-'-t f` i / C.1ExcellTemplalesl(HDP&S•DFusion xlsIShaall SGEOSERVERlDataDrive1Synlhetics12Q13SYNTHETICSt118,-F8R-CAMPBELLStL13118-04CAMPBELLSOS-38.xlejSheet1 L13118-04-04 12/18113 544 Braddock Avenue • East Pittsburgh, PA 15112 • 412-823-7600 • FAX 412-823-8999 • www.geotechnics.net PEEL AND SHEAR TEST RESULTS DESTRUCTIVE SEAM TESTING ASTM D 6392 CLIENT: CLIENT PROJECT: PROJECT NO.: LAB ID NO.: MATERIAL: SEAM TYPE: gINTEGRITY IN TESTING technics FROEHLING & ROBERTSON, INC. CAMPBELLS SOUP SUPPLY "B" FIELD EXPANSION L13118-04 L13118-04-05 60 MIL HDPE DOUBLE FUSION SAMPLE I.D.: DS-37 PEEL ADHESION INTEGRITY IN TESTING REPLICATE No. PEAK LOAD (lbs/in) EPA BREAK CLASSIFICATION CODE PEEL INCURSION (%) OUTSIDE TRACK (WELD "Al 1 132.1 SE1 <10 2 125.7 SE1 <10 3 129.2 SE1 <10 4 116.4 SE1 <10 5 126.6 SE1., <10 AVERAGE 126.0 STD. DEV. . . .5.29 .. .. • INSIDE TRACK (WELD "B") 1 131.2 .. SE1 <10 2 123.3 SE1 <10 3 118.4 SE1 <10 4 123.3 r SE1 <10 5 135.6 SE1 . <10 AVERAGE 126.4 STD. DEV. 6.18 BONDED SEAM (SHEAR) STRENGTH REPLICATE No. PEAK LOAD (Ibs/in) EPA BREAK CLASSIFICATION CODE 1 142.1 SE1 2 145.2 SE1 3 .: 145.0 SE1 4 * 144.2 SE1 5 146.6 SE1 AVERAGE 144.6 STD. DEV. 1.48 CHECKED BY: C ExcePTer laIestjHDP&S-DFus;at.z15JSheetl NGEOSERVERIData DrivelSyntheticst2013 SYNTHETICSl118 - F&R - CAMPBELLSI[L13118-04 CAMPBELLS DS37.x1s1Shaet1 DATE: V)*--k g k L13118.04-05 12I18113 544 Braddock Avenue • East Pittsburgh, PA 15112 • 412-823-7600 • FAX 412-823-8999 • www.geotechnics.net PEEL AND SHEAR TEST RESULTS DESTRUCTIVE SEAM TESTING ASTM D 6392 CLIENT: CLIENT PROJECT: PROJECT NO.: LAB ID NO.: MATERIAL: SEAM TYPE: gtechnics FROEHLING & ROBERTSON, INC.. CAMPBELL'S SOUP SUPPLY "B" FIELD EXPANSION L13118-04 L13118-04-06 60 MIL HDPE DOUBLE FUSION SAMPLE I.D.: DS-38 PEEL ADHESION INTEGRITY IN TESTING INTEGRITY IN TESTING REPLICATE No. PEAK LOAD EPA BREAK CLASSIFICATION PEEL INCURSION (Ibs/in) CODE (%) OUTSIDE TRACK (WELD "A") 1 109.5 SE1 <10 2 113.9 SE1 <10 3 106.1 SE1 <10 4 111.5 SE1 <10 5 _ 115.2 SE1.' <10 AVERAGE 111.2 STD. DEV.. 3.23.. INSIDE TRACK (WELD "B") 1 124.9 SE1 <10 2 127.3 SE1 <10 3 123.1 SE1 <10 4 128.5 SE1 <10 5 124.4 SE1 <10 _ AVERAGE 125.6 . STD. DEV. 1.97 BONDED SEAM (SHEAR) STRENGTH REPLICATE No. PEAK LOAD (Ibsrin) EPA BREAK CLASSIFICATION CODE 1 157.5 SE1 2 152.8 SE1 3 152.6 SE1 4 153.7 SE1 5 151.1 SE1 AVERAGE 153.5 STD. DEV. 2.15 CHECKED BY: D DATE: 1 '`t T-t 3 C:lExcenTamplales\[HDPSS-0Fusion,xl31Shee 1 llGEOSERVER1Data DrivalSynihellcs12013 SYNTHETICSl118 - F&R', CAMPBELLS413t 18.04 CAMPBELLS 03.38.xlsIShee11 L13118.04-06 12118113 544 Braddock Avenue • East Pittsburgh, PA 15112 • 412-823-7600 • FAX 412-823-8999 • www.geotechnics.net PEEL AND SHEAR TEST RESULTS DESTRUCTIVE SEAM TESTING ASTM D 6392 CLIENT: CLIENT PROJECT: PROJECT NO.: LAB ID NO.: MATERIAL: SEAM TYPE: Gtechnics FROEHLING & ROBERTSON, INC.. CAMPBELL'S SOUP SUPPLY "B" FIELD EXPANSION L13118-04 Li 3118-04-07 60 MIL HDPE DOUBLE FUSION SAMPLE I.D.: DS-39 PEEL ADHESION IMEGR iY INTFSTING INTEGRITY 1N TESTING REPLICATE No. PEAK LOAD EPA BREAK CLASSIFICATION PEEL - INCURSION (Ibs/in) CODE (%) OUTSIDE TRACK (WELD 'A') 1 121.3 SE1 <10 2 120.1 SE1 <10 3 .: 128.4 SE1 <10 4 125.4 SE1 <10 5 126.0 SE1 <10 AVERAGE 124.2 STD. DEV. 3.08 INSIDE TRACK (WELD "B") 1 120.2 SE1 <10 2 114.4 SE1 <10 3 120.8 SE1 <10 4 118.7 SE1 <10 5 _ 121.6 SE1 <10 AVERAGE 119.1 STD. DEV. 2.55 BONDED SEAM (SHEAR) STRENGTH REPLICATE No. PEAK LOAD (Ibs/in) EPA BREAK CLASSIFICATION CODE 1 150.7 SE1 2 147.8 SE1 3 150.3 SE1 4 149.2 SE1 5 147.6 SE1 AVERAGE 149.1 STD. DEV. 1.26 CHECKED BY: 9 DATE: �—, T-13 C.1Excenem pls tesgHDP&S-0Fusion.xl siSheall HGEOSERVER1Dela DrivalSynthmics12013 SYNTHETICSl118 - F8R - CAMPBELLSi[L1311 B-04 CAMPBELLS DS•39MsISheell L13118-04.07 12/18/13 544 Braddock Avenue • East Pittsburgh, PA 15112 • 412-823-7600 • FAX 412-823-8999 • www.geotechnics.net PEEL AND SHEAR TEST RESULTS DESTRUCTIVE SEAM TESTING ASTM D 6392 CLIENT: CLIENT PROJECT: PROJECT NO.: LAB ID NO.: MATERIAL: SEAM TYPE: FROEHLING & ROBERTSON, INC. CAMPBELL'S SOUP SUPPLY "B" FIELD EXPANSION L13118-04 L13118-04-08 60 MIL HDPE DOUBLE FUSION SAMPLE I.D.: DS-40 PEEL ADHESION technics INTEGRITY IN TESTING INTEGRITY 1N TESTING REPLICATE No. PEAK LOAD EPA BREAK CLASSIFICATION PEEL INCURSION (Ibs/in) CODE (%) OUTSIDE TRACK (WELD "A") 1 127.8 SE1 <10 2 123.2 SE1 <10 3 123.6 SE1 <10 4 132.9 SE1 <10 5 126.0 SE1 <10 AVERAGE 126.7 STD. DEV. 3.52 _ INSIDE TRACK (WELD "B") 1 137.1 SE1 <10 2 116.1 SE1 <10 3 125.8 SE1 <10 4 125.5 SE1 <10 5 130.8 SE1 <10 AVERAGE 127.1 STD. DEV. 6.91 BONDED SEAM (SHEAR) STRENGTH REPLICATE No. PEAK LOAD (Ibs/in) EPA BREAK CLASSIFICATION CODE 1 147.1 SE1 2 145.1 SE1 3 145.5 SE1 4 143.0 SE1 5 143.4 SE1 AVERAGE 144.8 STD. DEV. 1.49 CHECKED BY: 3E DATE: 0-'t7'13 C;fExcel\TemplatesgHDP&S-DFusion xlsJSheetl 11GEOSERVER1Oata DrivelSynlheticst2013 SYNTHETICS1118- F&R - CAMPBELLSl(L13118.04 CAMPBELLS DS 4O.xlsJSheett L13118-04-08 12/1a/13 544 Braddock Avenue • East Pittsburgh, PA 15112 • 412-823-7600 • FAX 412-823.8999 • www.geotechnics.net PEEL AND SHEAR TEST RESULTS DESTRUCTIVE SEAM TESTING ASTM D 6392 CLIENT: CLIENT PROJECT: PROJECT NO.: LAB ID NO.: MATERIAL: SEAM TYPE: FROEHLING & ROBERTSON, INC. CAMPBELL'S SOUP SUPPLY "B" FIELD EXPANSION L13118-04 L13118-04-09 60 MIL HDPE DOUBLE FUSION SAMPLE I.D.: DS-41 PEEL ADHESION technics INTEGRITY IN TESTING INTEGRITY TESTING REPLICATE No. PEAK LOAD EPA BREAK CLASSIFICATION PEEL INCURSION -: (Ibs/in) CODE (%) OUTSIDE TRACK (WELD "A') 1 127.3 SE1 <10 2 130.2 SE1 <10 3 127.4 SE1 <10 4 127.6 SE1 <10 5 129.6 SE1 <10 AVERAGE 128.4 STD. DEV. 1.23 INSIDE TRACK (WELD "B") 1 131.2 SE1 <10 2 124.5 SE1 <10 3 131.2 SE1 <10 4 132.2 SE1 <10 5 132.9 SE1 <10 AVERAGE 130.4 STD. DEV. 3.02 - BONDED SEAM (SHEAR) STRENGTH REPLICATE No. PEAK LOAD (Ibs/in) EPA BREAK CLASSIFICATION CODE 1 163.9 SE1 2 162.0 SE1 3 161.6 SE1 4 161.3 SE1 5 160.9 SE1 AVERAGE 161.9 STD. DEV. 1.04 CHECKED BY: Be DATE: earl g—( 3 C:1ExceATemplalest(HDPBS-DFusian.x sjSheet1 11GEOSERVER1Datn Drive1SynlhetIcs12013 SYNTHETICS1118.- FBR CAMPBELLSI(L13118434 CAMPBELLS DS-41.4s1Sheet1 L13118.04.08 12118113 544 Braddock Avenue • East Pittsburgh, PA 15112 • 412-823-7600 • FAX 412-823-8999 • www.geotechnics.net PEEL AND SHEAR TEST RESULTS DESTRUCTIVE SEAM TESTING ASTM D 6392 CLIENT: CLIENT PROJECT: PROJECT NO.: LAB ID NO.: MATERIAL: SEAM TYPE: eotechnics FROEHLING & ROBERTSON, INC. CAMPBELL'S SOUP SUPPLY "B" FIELD EXPANSION L 131.18-04 L13118-04-10 60 MIL HDPE DOUBLE FUSION SAMPLE I.D.: DS-42 PEEL ADHESION INTEGRITY IN TESTING REPLICATE No. PEAK LOAD EPA BREAK CLASSIFICATION PEEL INCURSION (lbs/in) CODE (%) OUTSIDE TRACK (WELD "A") 1 131.1 SE1 <10 2 132.7 SE1 <10 3 121.3 •SE1 <10 4 128.4 SE1 <10 5. 125.9 SE1 <10 AVERAGE 127.9 STD. DEV. . . 4.03 INSIDE TRACK (WELD "8") 1 130.6 SE1 <10 2 . 131.9 SE1 <10 3 125.7 SE1 <10 4, 136.4 SE1 <10 5 130.2 SE1 . <10. AVERAGE 131.0 STD. DEV. 3.43 BONDED SEAM (SHEAR) STRENGTH REPLICATE . No. PEAK LOAD (Ibs/in) EPA BREAK CLASSIFICATION CODE 1 150.4 SE1 2 149.5 SE1 3 150.7 SE1 4 148.1 SE1 5. 153.0 SE1 AVERAGE 150.3 STD. DEV. 1.61 CHECKED BY: c. DATE: / D--I SINC5 C.lExcnRTemplatesl[HDP&S OFusion.xts1Sheet1 11GEOSERVER'Data DrivaLSyntheticsl2013 SYNTHETICS111 B ; F&R - CAMPBELLSyL1311 B-04 CAMPBELLS DS-42.xtsjSheetl L13118-04-10 12/1 B/13 544 Braddock Avenue • East Pittsburgh, PA 15112 • 412-823-7600 • FAX 412-823-8999 • www.geotechnics.net PEEL AND SHEAR TEST RESULTS DESTRUCTIVE SEAM TESTING ASTM D 6392 CLIENT: CLIENT PROJECT: PROJECT NO.: LAB ID NO.: MATERIAL: SEAM TYPE: eatechnics FROEHLING & ROBERTSON, INC.. CAMPBELL'S SOUP SUPPLY "B" FIELD EXPANSION L13118-04 L13118-04-11 60 MIL HDPE DOUBLE FUSION SAMPLE I.D.: DS-43 PEEL ADHESION INTEGRITY IN TESTING REPLICATE PEAK EPA BREAK PEEL No. LOAD CLASSIFICATION INCURSION (Ibs/in) CODE (%) OUTSIDE TRACK (WELD "A") 1 115.6 SE1 <10 2 117.4 SE1 <10 3 111.2 SE1 <10 4 114.4 SE1 <10 5 11.1.9 ... SE1 <10 AVERAGE - 114.1 STD. DEV. 2.30 INSIDE TRACK (WELD "B") 1 119.4 SE1 <10 2 121.4 SE1 <10 3 124.0 SE1 <10 4 117.8 SE1 <10 5 107.2 SE1 .. <10 AVERAGE 118.0 STD. DEV. . 5.77 BONDED SEAM (SHEAR) STRENGTH REPLICATE No. PEAK LOAD (IbsTn) EPA BREAK" CLASSIFICATION CODE 1 157.5 SE1 2 153.9 . SE1 3 152.7 .. SE1 4 153.2 SE1 5 152.2 SE1 AVERAGE 153.9 STD. DEV. 1.89 CHECKED BY: e DATE: 1D---4 F`(3 C:1Exci Templates)[HDPBS-DFuslon.xls]Sheet1 11GEOSERVERIDala DrivMSynihaEcs12013 SYNTHETICS1118 - F&R - CAMPBELLS'L13118-04 CAMPBELLS OS 43.xis1Sheeh:: . L13118-04-11 12/18713 544 Braddock Avenue • East Pittsburgh, PA 15112 • 412-823-7600 • FAX 412-823-8999 • www.geotechnics.net lefl) Tull/ INTERNATIONAL Designation: D6392 -12 Standard Test Method for Determining the Integrity of Nonreinforced Geomembrane Seams Produced Using Thermo -Fusion Methods' This standard is issued under the fined designation D6392; the number immediately, following the designation indicates the year of original adoption or, in the ease of revision. the year of last revision. A number in parentheses indicates the year of Iasi reapproval. A superscript epsilon (e) indicates an editorial change since the last revision or reapproval. 1. Scope 1.1 This test method describes destructive quality control and quality assurance tests used to determine the integrity of geomembrane seams produced by thermo-fusion methods. This test method presents the procedures used for determining the quality of nonbituminous bonded seams subjected to both peel and shear tests. These test procedures are intended for nonreinforced geomembranes only. 1.2 The types of thermal field seaming techniques used to construct geomembrane seams include the following. 1.2.1 Hot Air :This technique introduces high -temperature air or gas between two geomembrane surfaces to facilitate melting. Pressure is applied to the top or bottom geomembrane, forcing together the two surfaces to form a continuous bond. 1.2.2 Hot Wedge (or Knife) --This technique melts the -two geomembrane surfaces to be seamed by running a hot metal wedge between them. Pressure is applied to the top or bottom geomembrane, or both, to form a continuous bond. Some seams of this kind are made with dual bond tracks separated by a nonbonded gap. These seams are sometimes referred to as dual .hot wedge seams or double -track seams. 1.2.3 Extrusion This technique encompasses extruding molten resin between two geomembranes or at the edge of two overlapped geomembranes to effect a continuous bond. 1.3 The types of materials covered by this test method include the following. 1.3.1 Very Low. Density Polyethylene (VLDPE). 1.3.2 Linear Low Density Polyethylene (LLDPE). 1.3.3 Vert Flexible Polyethylene (VFPE). 1.3.4 Linear Medium Density Polyethylene (LMDPE). 1.3.5 Higli Density Polyethylene (HDPE). 1.3.6 Polyvinyl Chloride (PVC). 1.3.7 Flexible Polypropylene (fPP). NOTE I —The polyethylene identifiers presented in I.3.1-1.3.5:describe the types of materials typically tested using this test method. These are t This test method is under the jurisdiction of ASTM Committee D35 on Geosynthetics and is the direct responsibility of Subcommittee D35.10 on Geomem- branes. Current edition approved July I, 2012. Published September 2012. Originally approved in 1999. Last previous edition approved in 2008 as D6392-08. DOI: 10.1520/D6392-12. industry accepted trade descriptions and are not technical material classifications based upon material density. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. 1t is the responsibility of the user of this standard to establish appro- priate safety and health practices and determine the applica- bility of regulatory liruitations prior to use. 2. Referenced Documents 2.1 ASTM Standards:2 D638 Test Method for Tensile Properties of Plastics D4439 Terminology for Geosynthetics D5199 Test Method for Measuring the Nominal Thickness of Geosynthetics - D5994 Test Method for Measuring Core Thickness of Tex- tured Geomembranes 2.2 EPA Standards: EPA/600/2-88/052 Lining of Waste Containment and Other Containment Facilities; Appendix N, Locus of break codes for various types of FML seams3 3. Terminology 3.1 Definitions of Terms Specific to This Standard: - 3.1.1 geomembrane, n—essentially impermeable geosyn- thetic composed of one or more synthetic sheets. 3.1.2 quality assurance, n—all planned and systematic ac- tions necessary to provide adequate confidence that an item or a facility will perform satisfactorily in service. 3.1.3 quality control, n—the operational techniques and the. activities, which sustain a quality of material, product, system, or service that will satisfy given needs; also the use of such techniques and activities. 4. Significance and Use 4.1 The use of geomembranes as barrier materials to restrict liquid migration from one location to another in soil and rock For referenced ASTM standards, visit the ASTM websitc, www.astm.org, or contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM Standards volume information, refer to the standard's Document Summary page on the ASTM website. Available from the Superintendent of Documents. US Government Printing Office, Washington. DC 20402. Copyright 0 ASTM International, 109 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 10429-2959. United States Copyright by ASTM Intl (all rights reserved); cy D6392 —12 has created a need for a standard test method to evaluate the quality of geomembrane seams produced by thermo-fusion methods. In the case of geomembranes, it has become evident that geomembrane seams can exhibit separation in the field under certain conditions. Although this is an index type test method used for quality assurance and quality control purposes, it is also intended to provide the quality assurance engineer with sufficient seam peel and shear data to evaluate seam quality. Recording and reporting data, such as separation that occurs during the pee! test and elongation during the shear test, will allow the quality assurance engineer to take measures necessary to ensure the repair of inferior seams during facility construction, and therefore, minimize the potential for seam separation in service. 5. Apparatus 5.1 Tensile instrumentation shall meet the requirements outlined in Test Method D638. 5.2 Grip Faces —Grip faces shall be 25 mm (1 in.) wide and a minimum of 25 mm (1 in.) in length. Smooth rubber, fine serrated or coarse serrated grip faces have all been found to be suitable for testing geomembrane seams. 6. Sample and Specimen Preparation 6.1 Seam Samples —Cut a portion of the fabricated seam sample from the installed liner in accordance with the project specifications. It is recommended that the cutout sample be 0.3 m (1 ft) wide and 0.45 m (1.5 ft) in length with the seam centered in the middle. 6.2 Specimen Preparation —Ten specimens shall be cut from the sample submittal. The specimens shall be die cut using a 25 mm (nominal 1 in.) wide by a minimum of 150 mm (nominal 6 in.) long die. Specimens that will be subjected to peel and shear tests shall be selected altemately from the sample and labeled as shown in Fig. 1. Specimens shall be cut such that the seam is perpendicular to the longer dimension of the strip specimen. 6.3 Conditioning —Samples should be conditioned for 40 h in a standard laboratory environment that conforms to the requirements for testing geosynthetics as stated in Terminology D4439. Long sample conditioning times typically are not possible for most applications that require seam testing. Prior to testing, samples should be conditioned for a minimum of 1 h at 23 ± 2°C and a relative humidity between 50 and 70 %. 7. Destructive Test Methods 7.1 Peel Testing —Subject five specimens to the 90° "T- Peel" test (see Fig. 2). If the tested sample is a dual hot wedge seam, five specimens must be examined for each external track of the seam. Maintaining the specimen in a horizontal position throughout the test is not required. Fully grip the test specimen across the width of the specimen. Grip the peel specimen by securing grips 25 mm (1 in.) on each side of the start of the seam bond, a constant machine cross head speed of 50 mm (2 in.)/min for HDPE, LMDPE, and PVC, 500 mm (20 in.)/min for LLDPE, VLDPE, VFPE, and fPP. The test is complete when the specimen ruptures. 7.2 Shear Testing —Subject five specimens to the shear test (see Fig.; 2). Fully support the test specimen within the grips across the width of the specimen. Secure the grips 25 mm ('1 in.) on each side of the start of the seam bond, a constant machine cross head speed of 50 mm (2 in.)/min for LMDPE and HDPE, 500 mm (20 in.)/min for fPP, LLDPE, VFPE, VLDPE, and PVC. The test is complete for HDPE and LMDPE once the specimen has elongated 50 %. PVC, fPP, LLDPE, VFPE and VLDPE geomembranes should be tested to rupture. NOTE 2—Both peel and shear tests for fPP, LLDPE, VLDPE, and PVC geomembranes have been tested routinely at both 2 and 20 in./min. When conducting seam peel or shear testing for quality control, or quality FIG. 1 Seam Sample • PEEL #1 SHEAR #1 PEEL#2 SHEAR #2 PEEL #3 SHEAR #3 PEEL #4 SHEAR #4 PEEL #5 SHEAR #5 Copyright by ASTM Int'I (all rights reserved); IJJ' D6392 —12 FIG. 2 Shear and T Peel Specimens assurance purposes, or both, it may be necessary to select the manufac- turer's recommended testing speed. In the absence of explicit testing speed requirements, follow those recommended in 7.1 and 7.2.. 8. Calculations and Observations 8.1 Estimate of Seam Peel Separation —Visually estimate the seam separation demonstrated prior to rupture for peel specimens. The estimate shall be based upon the proportion of the area of the separated bond, to the area of original bonding to the nearest 5%. However, if at any point across the width of the peel specimen, seam separation continues to the other side of the bonded area, the estimate of seam peel separation shall be 100 % regardless of the proportion of the area of the separated bond to the area of the original bonding. 8.1.1 In cases of dispute, the peel separation estimate may be documented via direct measure. 8.1.2 Procedure: Determine the total area of bonded area for which the peel test was performed using calipers to span measure the maximum length of the bond being careful not include squeeze -out or tack welded areas. Verify the seam width of one inch. 8.1.3 Assign appropriate geometric shapes to approximate the area of each separated portion of the peeled zone. 8.1.4 Place the peeled specimen flat against the surface of a flat bed scanner set at 100% scale. 8.1.5 Produce a record of the peeled area for easier shape assignment and peeled area determination. Care should be taken to assure intimate contact between the peeled specimen and the scanner surface so as to preserve dimensions. 8.1.6 Using the same calipers, record the dimensions of each peeled area. 8.1.7 Using the recorded dimensions, calculate percent peel as follows and round to the nearest 5%. S = I00* A/A (1) where: S = Percent peel separation A = Area of peel separation measured = Area of original bonded region (not including track weld, tack weld, or squeeze -out, see Note 3 and Note 4) NOTE 3—During the thermo-fusion welding process, some of the melted polymer may be shifted to the outside of the weld during the pressing of the geomembrane panels together. This melted polymer is sometimes called "squeeze -out" or "bleed out" and is not considered part of the bond. Care must be exercised during estimation of the seam peel separation to segregate the squeeze or bleed out area from the peeled bond area. The reported peel separation shall include the peeled bond area only. NOTE 4—The exact area of original bond (Ao) for use in Equation 1 for peel separation is sometimes ambiguous. For most cases, the area of peel measured for thermo fusion extrusion seams is that area defined by the width of the specimen multiplied by the distance between the termination of the top geomembrane and the outermost edge of the extrusion weld along the bottom geomembrane. To be counted as part of the weld, the extruded material must be at least as thick as the nominal thickness of the geomembrane. 8.2 Rupture Mode Selection —Determine the locus of break for both the peel and shear specimens as shown in Figs. 3 and 4: The locus of break for shear specimens that do not rupture prior to test end (50 % elongation) shall be interpreted as occurring in the membrane that exhibits yielding. Copyright by ASTM Int'I (all rights reserved); 3 D6392 —12 Schematic of Untested Specimen tWO 9 ' Wald .. „a,.. =' Q,_.,' Top Sheet Direction of Initial Peal Types of Break t z� Bottom Sheet Location of Break Break Code Description AD Adhesion Failure BRK AD-BRK Break in sheeting. Break can be in either top or bottom sheet Break in outer edge of seam. Break can be in either top or bottom sheet. Break at inner edge of seam through both sheets. Break in first seam after some adhesion failure. Break can be in either top or bottom sheet. Separation In the plane of the sheet. Break can be in either top or bottom sheet. FIG. 3 Locus -of -Break Codes forUua11 HgelSe�rris7in Unrelnforced Geomembranes Tested for Seam Strength In Shear and Peel Modes 8.3 Shear Percent Elongation —Calculate the percent elon- gation on shear specimens according to Eq 2. Divide the extension at test end by the original gage length of 25 mm and multiply by 100. Elongation(E) = X 100 (2) where: L = extension at test end, and Ln = original gauge length. Nomm 5—The intent of measuring elongation using this test method is to identify relatively large reductions in typical break elongation values of seam samples. Length is defined as the distance from one grip to the seam edge. Using this definition implies that all strain experienced by the specimen during the shear test occurs on one side of the seam. Of course this assumption is inaccurate, since some strain will occur on each side of the seam, and in the seam area itself; however, it is difficult to make an accurate measurement of the strain distribution which occurs in the specimen during testing. Further, it is not critical to know the exact location of all the strain which occurs during testing but rather to simply identify when significant reductions in elongation (when compared with the typical elongation of a new tnaterial) have occurred. 9. Report 9.1 The report shall include the following information. SIP 9.1.1 Report the individual peel and shear specimen maxi- mum unit tension values in N/mm of width (lb/in.). NosE.6—If requested, report the maximum peel or shear stress. This calculation will require an accurate measurement of thickness for each specimen. These measurements should be made in accordance with Test Method D5I99 for smooth geomembranes and Test Method D5994 for textured geomembranes. 9.1.2 Report the cross head speed used during peel and shear testing. 9.1.3 Report the average of the individual peel and shear sample values recorded. 9.1.4 If the peel or shear specimen does not rupture, report the elongation at the maximum cross -head travel limitation. If the gage length is reduced to less than 25 mm (1 in.), this must be noted in the report. 9.1.5 Report the mode of specimen rupture for peel and shear specimens according to Fig. 3 or Fig;. 4. Copyright by ASTM Int'I (all rights reserved); Types of Break ===‘ Off -Center Bead ce' D6392 - 12 Schematic of Untested Specimen Baed� DuterArea �( Buffed Area Hot Tack (determinated) Location of Break Description Break Code AD1 Failure in adhesion. Specimens may also delaminate under the bead and break through the thin extruded material in the outer area. AD2 Failure in adhesion. AD-WLD0)' Break through the fillet. SE1 Break at seam edge in the bottom sheet (applicable to shear only). SE2 Break at seam edge in the top sheet (applicable to shear only). SE3 Break at seam edge in the bottom sheet (applicable to peel only). BRK1 Break in the bottom sheeting. A "B" in parebtheses following the code means the specimen broke in the buffed area. BRK2 Break in the top sheeting. A "B" in parebiheses following the code means the specimen broke in the buffed area.;. AD-BRK Break in the bottom sheeting after some adhesion failure between the fillet and the bottom sheet. HT Break at the edge of the hot tack for specimens which could not be delaminated in the hot tack. SIP Separation in the plane of the sheet. (1) Acceptance of AD-WLD breaks may depend on whether test values meet a minimum specification value. FIG. 4 Locus -of -Break Codes for FlliefExtrusion;Welci Seams, in Unrelnforced Geomembranes Tested for Seam Strength In Shear and -"zJ Peel Modes Nora 7—"Locus-of-Failure" (Figs.,3 and 4) include only some of the typically found seam configurations found in the industry.When this test method is applied to seams bonded in configurations other than those identified in Fig. 3 or Fig. 4, the users of this test method must agree on applicable descriptions for modes of specimen rupture. 10. Precision and Bias 10.1 No statement can be made at this time concerning precision or bias. Copyright by ASTM Int'I (all rights reserved); t' D6392 -12 ASTM International takes no position respecting the validity of any patent rights asserted in connection with any item mentioned in this standard. Users of this standard are expressly advised that determination of the validity of any such patent rights, and the risk of infringement of such rights, are entirely their own responsibility. This standard is subject to revision at any time by the responsible technical committee and must be reviewed every five years and if not revised, either reapproved or withdrawn. Your comments am invited either for revision of this standard or for additional standards and should be addressed to ASTM International Headquarters. Your comments will receive careful consideration at a meeting of the responsible technical committee, which you may attend. if you feel that your comments have not received a fair hearing you should make your views known to the ASTM Committee on Standards, at the address shown below. Thls standard is copyrighted by ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 1942E-2959, United States. Individual reprints (single or multiple copies) of this standard may be obtained by contacting ASTM at the above address or at 610-832-9585 (phone), 610-832-9555 (fax), or service@astm.org (e-mail); or through the ASTM website (wwwastm.org). Permission rights to photocopy the standard may also be secured from the ASTM website (www.asfm.orgf COPYRIGHT/). Copyright by ASTM Intl (all rights reserved); 6 Material Quality www.dewberry.com GSE Roll Allocation Order SO-070563 Customer Plastic Fusion Fabricators, Inc. Project Name Campbell's Soup Supply Company Ro1I# Resin Lot Product Code Mfg Date Length 105167917 13F1133 HST-060AE-WBB-B-WO-T 7/11/2013 540 GSF R_2.4-n9n rav ni n2/in From:FAX SERVICE 007 To:12812308630 SEN5C89 COA 06/17/2013 00:17 Page 5 of 23 Formosa Plastics° Msg#1706680.0.1 FORMOSA PLASTICS CORPORATION, TEXAS 201 FORMOSA DRIVE PHONE:( 888 )FPCUSA3 PO BOX 700 POINT COMFORT TX 77978 Certificate of Analysis CUSTOMER:GSE LINING TECHNOLOGY, IN UP TRACK 14732 WESTFIELD HOUSTON PRODUCT :HL3812 RAILCAR TEST ITEM FPAX950392 TX 77070 S/0 NO : SEN5C89 CUSTOMER PO : 03-073019 DATE SHIPPED: 6/16/13 LOT NO : 13F1133 WEIGHT (LB) 198,250.00 CUSTID:FT03112 SPIDM4 REFERENCE METHOD TEST VALUE Melt Index,g/lOmin ASTM D1238 .070 HLMI, g/10 min. ASTM D1238 11.6 Density, g/cm3 ASTM D1505 .9372 QC SUPERVISOR: LINDA KAO GSE Environmental, LLC ENVIRONMENTALL' ROLL TEST. DATA REPORT Page 1 of 1 Report Date: JuI/11 /2013 Sales Order No. Customer Name Project Location Product Name ROL Number SO-070563 Plastic Fusion Fabricators, Inc. Maxton NC US HST-060AE-WBB-B-WO-T Roll Number Carbon Stack r.,r Yield Yield Yield Yield Break Beek Break ' Break Teat Tear Carbon Dispersion Asperity '•'Rvamgs,�{ rM,r 8trmgtl� SWngfh Ebrgaaen Ebrk�utrorr 94anpt7� Suon�th Ebrrpatbn Bongaeon Resistance Resistance Pundaro Black ASTM Heiaht T€tiY,kheasl 5Tttrtknaisi ASTM ASTM A5TA1 ASih1 ASTM ASTM A5TM ASTM ASTM ASTM . Resistance Danvly Content 05598 ASTM .A811134 it4STW 08083 (pp) 08BW (pp) 08823 )%) D8663 (04) D8803 (pp) D8693 (PW) . . 08823 (%) 00003 (%) D1004 (les) D1004 (les) ASTM ASTM ASTM (Views in 137488 (n:ls) 0599 {.(1), 6$994 ri isM MD TD MD TO MD TO MD . TO MD TO ' 04033 (lM) 01505 )990) 134216 (%) con-Cnt2) Side A 105187917 6:1 75_9.D. 137 140 17 17 245 228 700 669 50 48 144 0.944 2.18 10 23 Laboratory Manager This test report shall not be reproduced, except in full, without written approval of the laboratory. 19103 Gundle Road Houston, TX 77073 GSE-8.2,4-029 Rev01 - - 02/10 GSE Roll Allocation Order SO-070563 Customer Plastic Fusion Fabricators, Inc. Project Name Campbell's Soup Supply Company RoII# Resin Lot Product Code Mfg Date Length 105167927 13F1133 HDS-060AE-WBB-B-00 7/11/2013 560 105167928 13F1133 HDS-060AE-WBB-B-00 7/11/2013 560 105167929 13F1133 HDS-060AE-WBB-B-00 7/11/2013 560 105167930 13F1133 H DS-060AE-W BB-B-00 7/11/2013 560 105167931 13F1133 HDS-060AE-WBB-B-00 7/11/2013 560 105167932 13F1133 HDS-060AE-WBB-B-00 7/12/2013 560 105167933 13F1133 HDS-060AE-WBB-B-00 7/12/2013 560 105167934 13F1133 HDS-060AE-WBB-B-00 7/12/2013 560 105167935 13F1133 HDS-060AE-WBB-B-00 7/12/2013 560 105167936 13F1133 H DS-060AE-W BB-B-00 7/12/2013 560 105167937 13F1133 HDS-060AE-WBB-B-00 7/12/2013 560 From:FAX SERVICE 007 06/17/2013 00:17 Page 5 of 23 To:12812308630 SEN5C89 COA Ms01706680.0.1 4\c -Formosa Plastics" FORMOSA PLASTICS CORPORATION, TEXAS 201 FORMOSA DRIVE PO BOX 700 POINT COMFORT TX 77978 Certificate of Analysis CUSTOMER:GSE LINING TECHNOLOGY, IN UP TRACK 14732 WESTFIELD HOUSTON PRODUCT :HL3812 RAILCAR TEST ITEM FPAX950392 TX 77070 PHONE:( 888 )FPCUSA3 S/0 NO : SEN5C89 CUSTOMER PO : 03-073019 DATE SHIPPED: 6/16/13 LOT NO : 13F1133 WEIGHT (LB) : 198,250.00 CUSTID:FT03112 SPIDM4 REFERENCE METHOD TEST VALUE Melt Index,g/l0min ASTM D1238 .070 HLMI, g/10 min. ASTM D1238 11.6 Density, g/cm3 ASTM D1505 .9372 QC SUPERVISOR: LINDA KAO Report Date:Jul/12/2013 a co 0 1- w J J ce BOL Number d Z U a HDS-060AE-WBB-B-00 Project Location U Z 0 0 2 Plastic Fusion Fabricators, Inc. Sales Order No. SO-070563 11u 0 0 0 0 0 0 0 0 0 0 0 m iilix 5261 '�' U QN . M IN') CONN N N CD CO- O) N a N N (V CV CV N CV CV tV N 01 O O d C C C O C O O O Fs 0 PI � V V V V V V V V V V ¢ 0 ,$v444vvv444v ¢o � 1 � 0) h N. 1,00 CO CO )'— )- N 1, a$� V V V V V V V V V V V C 0 �g�a N N N N co co m 0 0 0 a g F 0)) 00)) 0)) 0)) 0) 0) 00) O O O 0) 2RS x n2CO N N N 0) 01 V V V 0 CO CO CO m CO CO 03 03 W 03 CO Roll Number tl) 1') t9 CO 0 d) co 1') 0 CO P) 0 00 0D 0 0 0 0 0 OND R) N N N n) 0 f'D N N N t') f` 10 t0 tD t` h t` ti 2` t0 ti CO CO m ti n I` 1, N. is r` NV 0 V 7 M 6') c~') 6')i M M V VCIM WMM�V*I'M 0 0) 0 n 0 n t` m ti 0) 0) N N N N N N N N N N N � L-tD...t0..' ,t0�; 0) 0W "t0 0 t0 t0�.� N 444 0 6') f0) X 4N+) t0 r- 1, 3, h n r n 1'-- 6- r h tD t0 t0 t0 t0 t0 t0 t0 CD CO ID 1f) N N N N N N N N N N 0 0 0 0 0 0 0 0 0 0 0 Laboratory Manager GSE-8.2.4-029 Rev01 - - 02/10 19103 Gundle Road Houston, TX 77073 This test report shall not be reproduced, except in full, without written approval of the laboratory. GSE Roll Allocation Order SO-070563 Customer Plastic Fusion Fabricators, Inc. Project Name Campbell's Soup Supply Company RoII# Resin Lot Product Code Mfg Date Length 105167938 13F1133 H DS-060AE-W BB-B-00 7/12/2013 560 105167939 13F1133 HDS-060AE-WBB-B-00 7/12/2013 560 105167940 13F1133 HDS-060AE-WBB-B-00 7/12/2013 '560 105167941 13F1133 HDS-060AE-WBB-B-00 7/12/2013 560 105167942 13F1.133 HDS-060AE-WBB-B-00 7/12/2013 560 105167943 13F1133 HDS-060AE-WBB-B-00 7/12/2013 560 105167944 13F1133 HDS-060AE-WBB-B-00 7/12/2013 560 105167945 13F1152 HDS-060AE-WBB-B-00 7/12/2013 560 105167946 13F1152 H DS-060AE-W BB-B-00 7/13/2013 560 105167947 13F1152 HDS-060AE-WB13-B-00 7/13/2013 560 105167948 13F1152 HDS-060AE-WBB-B-00 7/13/2013 560 105167949 13F1152 H DS-060AE-W BB-B-00 7/13/2013 560 105167950 13F1152 HDS-060AE-WBB-B-00 7/13/2013 560 105167951 13F1152 HDS-060AE-WBB-B-00 7/13/2013 560 105167952 13F1152 HDS-060AE-WBB-B-00 7/13/2013 524 105167953 13F1152 HDS-060AE-WBB-B-00 7/13/2013 510 105167955 13F1152 HDS-060AE-WBB-B-00 7/13/2013 560 105167956 13F1152 H DS-060AE-W BB-B-00 7/13/2013' 560 105167957 13F1152 HDS-060AE-WBB-B-00 7/13/2013 560 105167958 13F1152 HDS-060AE-WBB-B-00 7/13/2013 560 105167959 13F1152 HDS-060AE-WBB-B-00 7/13/2013 560 105167960 13F1152 HDS-060AE-WBB-B-00 7/13/2013 560 105167961 13F1152 HDS-060AE-WBB-B-00 7/14/2013 560 105167962 13F1152 HDS-060AE-WBB-B-00 7/14/2013 560 105167963 13F1152 HDS-060AE-WBB-B-00 7/14/2013 560 105167964 • 13F1152 HDS-060AE-WBB-B-00 7/14/2013 560 105167966 13F1152 HDS-060AE-WBB-B-00 7/14/2013 370 105167967 13F1152 HDS-060AE-WBB-B-00 7/14/2013 560 105167968 13F1152 HDS-060AE-WBB-B-00 7/14/2013 560 105167969 13F1152 HDS-060AE-WBB-B-00 7/14/2013 560 105167970 13F1152 ' HDS-060AE-WBB-B-00 7/14/2013 560 105167971 13F1152 HDS-060AE-WBB-B-00 7/14/2013 560 105167972 13F1152 HDS-060AE-WBB-B-00 7/14/2013 560 105167973 13F1152 HDS-060AE-WBB-B-00 7/14/2013 560 105167977 13F1152 HDS-060AE-WBB-B-00 7/15/2013 560 From;FAX SERVICE 007 06/17/2013 00:17 Page 5 of 23 To:12812308630 SEN5C89 COA MsgH1706680.0.1 Formosa Plastics' FORMOSA PLASTICS CORPORATION, TEXAS 201 FORMOSA DRIVE PHONE:( 888 )FPCUSA3 PO BOX 700 POINT COMFORT TX 77978 Certificate of Analysis CUSTOMER:GSE LINING TECHNOLOGY, IN UP TRACK 14732 WESTFIELD HOUSTON PRODUCT :HL3812 RAILCAR TEST ITEM EPAX950392 TX 77070 S/0 NO : SEN5C89 CUSTOMER PO : 03-073019 DATE SHIPPED: 6/16/13 LOT NO : 13F1133 WEIGHT (LB) : 198,250.00 CUSTID:FT03112 SPIDM4 REFERENCE METHOD TEST VALUE Melt Index,g/lOmin ASTM D1238 .070 HLMI, g/10 min. ASTM D1238 11.6 Density, g/cm3 ASTM D1505 .9372 QC SUPERVISOR: LINDA KAO GSE Environmental, LLC ENVIRONMENTAL ROLL TEST DATA REPORT Page 1 of 2 Report Date:Jul/15/2013 Sales Order No. Customer Name Project Location Product Name BOL Number SO-070563 Plastic Fusion Fabricators, Inc. Maxton NC US HDS-060AE-WBB-B-00 Roll Number Carbon Black ,7'7----.1 Yintl Yield YIW Yield Break freak Bmak BreeN Tear Teec. Carbon Dispersion FAvar` ;. (:1G+een'un1' SbSTM ASTM EASTMan EWnpatiae StmTM SlSTM E1A Mae ESA Th Resistance Resistance Puncture Block ASTM �ilA5TMas �l)dcY.t(oes � 693 (p 993 ( A93 (%) A5TM 663 (p ASTM A57'M A93 ASTM ASTM Resistance Donsily Content 135596 ASTM '*'ADT_M % :_gr ) Dtk3M (ppi) 08593 (ppi) � DB893 DS593 (%) DeeM (opt) D5eT (pp,) DDti93 (%) OBe93 (%) D1004 (las) 01004 (Ibs) ASTM - ASTM ASTM (Views in. 3FS11i9(inis) ;D519S'( ) MD TD MO TD MO TD MO TD MD TD CHM Os) D1505 (W.) D421B VA) Ceti-Cat2) 105167938 105167939 105167940 105167941 105167942 105167943 105167944 105167945 105167946 105167947 105167948 105167949 105167950 .105167951 105167952 105167953 105167955 105167958 105167957 105167958 Al 105167959 160 105167960 0 105167961 105167962 105167963 105167984 105167966 105167987 105167968 105167969 105167970 105167971 pp61 105167972 f61: 105167973 60 6D 60 i 60q 60. 60 76 ' 61 60��0 60 6°) 60; 80, 60 6;1� g'1 60, 60) 60 )60 Z60 i:- 61 : 60;, 60i1 < f 61� Ir i 59 133 137 17 17 302 316 875 952 47 44 146 0.944 2.35 10 59 133 137 17 17 302 316 875 952 47 44 146 0.944 2.35 10 58 133 137 17 17 302 316 875 952 47 44 146 0.944 2.35 10 58 135 141 17 17 307 332 897 997 47 44 144 0.945 2.24 10 59 135 141 17 17 307 332 897 997 47 44 144 0.945 2.24 10 57 135 141 17 17 307 332 897 997 47 44 144 0.945 2.24 10 56 132 139 17 16 285 325 827 982 47 43 140 0.944 2.29 10 56 132 139 17 16 285 325 827 982 47 43 140, 0.944 2.29 10 57 132 139 17 16 285 325 827 982 47 43 140 0.944 2.29 10 57 131 140 17 16 279 298 839 939 46 43 139 0.946 2.61 10 57 131 140 17 16 279 298 839 939 46 43 139 0.946 2.61 10 57 131 140 17 16 279 298 839 939 46 43 139 0.946 2.61 10 59 140 149 17 16 301 313 854 920 48 45 142 0.945 2.52 10 59 140 149 17 16 301 313 854 920 48 45 142 0.945 2.52 10 59 140 149 17 16 301 313 854 920 48 45 142 0.945 2.52 10 57 ' 147 157 16 16 288 297 794 904 50 47 144 0.945 2.59 10 60 147 157 16 16 288 297 794 904 50 47 144 0.945 2.59 10 58 147 157 16 16 288 297 794 904 50 47 144 0.945 2.59 10 59 135 143 16 16 290 325 825 966 47 45 142 0.945 2.55 10 59 135 143 16 16 290 325 825 968 47 45 142 0.945 2.55 10 58 135 143 16 16 290 325 825 968 47 45 142 0.945 2.55 10 59 136 145 16 16 308 281 889 843 47 44 141 0.945 2.57 10 59 136 145 16 16 308 281 889 843 47 44 141 0.945 2.57 10 58 136 145 16 16 308 281 889 843 47 44 141 0.945 2.57 10 58 134 140 17 16 286 315 824 945 46 44 143 0.945 2.66 10 58 134 140 17 16 286 315 824 945 46 44 143 0.945 2.66 10 59 134 140 17 16 286 315 824 945 46 44 143 0.945 2.66 10 58 146 153 16 16 305 300 856 856 50 46 . 145 0.945 2.59 .10 59 146 153 16 16 305 300 856 856 50 46 145 0.945 2.59 10 58 146 153 16 16 305 300 856 856 50 46 145 0.945 2.59 10 60 142 150 16 16 289 322 835 950 49 46 146 0.945 2.62 10 58 142 150 16 16 289 322 835 950 49 46 146 0.945 2.62 10 59 142 150 16 16 289 322 635 950 49 46 •146 0.945 2.62 10 58 129 134 16 17 281 306 852 939 47 44 139 0.945 2.52 10 GSE Environmental, LLC ENVIRONMENTAL"' ROLL TEST DATA REPORT Page 2 of 2 Report Date:Jul/15/2013 Sales Order No. Customer Name Project Location Product Name BOL Number SO-070563 Plastic Fusion Fabricators, Inc, Maxton NC US HDS-060AE-WBB-B-00 Roll Number Carbon Black Yield Yield Yield Yldd Break Brook Brook Brook Tom Tar Carom Dispersion F;"Atiragai rMrv,ioo, Strength Sboogh Ebngalion El0000boo Strength Stronglh EWngobon • EWnga<bn Resistance Resistance Puncture 2y Black ASTM 'ontent 13S5416 1„r'ASTMnest ASTMF 08403(A(pp) 16803(pp) D86033%) D86933M(%) 06.093(AST(pASTpp) , D8003(MPW) 0861333(16) D66933M(%) D106r(lbs) D1081 Ohs) Resistance ASTM ASTM ASTASTM ASTM (Views in D5199 (niis) 05t00 (g 0g5 ; MD TD MO TO MO TO MO TD MD TD Ds833 Os) D1505 (grcc) 04218 (%) Cot t-Cat2) 105167977 'r?`'8.11 58 129 134 16 17 281 306 852 939 47 44 139 0.945 2.52 10 Laboratory Manager �-- This test report shall not be reproduced, except in full, without written approval of the laboratory. 19103 Gundle Road Houston, TX 77073 GSE-8.2.4-029 Rev01 - - 02/10 GSE Roll Allocation Order SO-070563 Customer Plastic Fusion Fabricators, Inc. Project Name Campbell's Soup Supply Company Ron Resin Lot Product Code Mfg Date Length 105167982 13F1152 H DS-060AE-W BB-B-00 7/15/2013 560 105167983 13F1152 HDS-060AE-WBB-B-00 7/15/2013 560 105167984 13F1152 HDS-060AE-WBB-B-00 7/15/2013 560 105167985 13F1132 HDS-060AE-WBB-B-00 7/15/2013 560 105167986 13F1132 H DS-060AE-W BB-B-00 7/15/2013 560 105167989 13F1132 - HDS-060AE-WBB-B-00 7/16/2013 560 105167990 13F1132 HDS-060AE-WBB-B-00 7/16/2013 560 105167991 13F1132 HDS-060AE-WBB-B-00 7/16/2013 560 Formosa Plastics FORMOSA PLASTICS CORPORATION, TEXAS 201 FORMOSA DRIVE PO BOX 700 POINT COMFORT TX 77978 Certificate of CUSTOMER:GSE LINING TECHNOLOGY, IN UP TRACK 14732 WESTFIELD HOUSTON PRODUCT :HL3812 RAILCAR TEST ITEM Melt Index,g/lOmin HLMI., g/10 thin. Density, g/cm3 FPAX200162 Analysis PHONE:( 888 )FPCUSA3 S/0 NO : SEN5C98 CUSTOMER PO : 03-073019 DATE SHIPPED: 6/28/13 TX 77070 LOT NO : 13F1152 WEIGHT (LB) : 198,350.00 CUSTID:FT03112 SPIDM4 REFERENCE METHOD ASTM D1238 ASTM D1238 ASTM.D1505 TEST VALUE .080 10.9 .9376 QC SUPERVISOR: LINDA KAO GSE Environmental, LLC ENVIRONMENTAL ROLL TEST DATA REPORT Page 1 of 1 Report Date:Jul/16/2013 Sales Order No. Customer Name Project Location Product Name BOL Number SO-070563 Plastic Fusion Fabricators, Inc. Maxton NC US HDS-060AE-WBB-B-00 Roll Number 105167982 105167983 105167984 105167985 105167986 105167989 105167990 105167991 Carbon Yield ck Yield Yield Yield Broek Bro k B,o k Break Tear Toar Carbon Biers f ,Avera`(N`F' ?rrjinnnu ,..- Stranplf' Sirerplh Ebnga! E1�pawn 54er h Sigh knn Ep68Mbn Resistance Resistance Puncture Black ASTM TtiisfcnassF -71 mss' ASTM ASTM ASTM ASTM ASTM ASTM E ASTM ASOM ASTM ASTM Resistance Dansily Content D5596 a-ASTM ASTPT . D5093 (pp) DBS83 (ppi) D8603 (%) D6693 (%) D8683 (pp() DO683 (ppi) D6093 (%) D6683 (%) D1004 ells) 01004 (Ill) ASTM ASTM ASTM (Views in 05199 BP4-0,051891,txis)', MD TD MD TD MD TO MI) TO MO ID D4633ells) D1505(gr¢) 0421B(%) Call-Cat2) 61 Laboratory Manager 58 142 152 16 17 286 334 812 992 49 46 140 0.945 2.56 10 59 141 139 17 17 303 305 888 936 48 45 142 0.945 2.51 10 59 141 139 17 17 303 305 888 936 48 45 142 0.945 2.51 10 57 141 139 17 17 303 305 888 936 48 45 142 0.945 2.51 10 59 145 147 16 16 310 314 878 924 49 48 145 0.945 2.48 10 59 145 147 16 16 310 314 878 924 49 48 145 0.945 2.48 10 58 145 147 16 16 310 314 878 924 49 48 145 0.945 2.48 10 59 142 154 16 16 329 351 914 1008 49 46 142 0.943 2.17 10 This test report shall not be reproduced. except in lull, without written approval of the laboratory. 19103 Gundle Road Houston, TX 77073 GSE-8 2.4-029 Rev01 - - 02/10 VIRONMENTAL GSE Environmental, LLC Roll Allocation List les Order: SO-070563 stomer Name: Plastic Fusion Fabricators, Inc. eject Name: PFF/Campbell Soup arial number 31427790 31427791 31427792 31427913 31427914 31427915 31427916 31427917 314279/8 31427919 31427920 31427921 31427922 31427923 31427924 31427925 31427926 31427927 31427928 31427929 31427931 31427932 31427933 31427934 31427935 31427936 31427937 31427938 31427939 31427940 31427941 Item Number FS2-200E-06-06-F-00 FS2-200E-06-06-F-00 FS2-200E-06-06-F-00 FS2-200E-06-06-F-00 FS2-200E-06-06-F-00 FS2-200E-06-06-F-00 FS2-200E-06-06-F-00 FS2-200E-06-06-F-00 FS2-200E-06-06-F-00 FS2-200E-06-06-F-00 FS2-200E-06-06-F-00 FS2-200E-06-06-F-00 FS2-200E-06-06-F-00 FS2-200E-06-06-F-00 FS2-200E-06-06-F-00 FS2-200E-06-06-F-00 FS2-200E-06-06-F-00 FS2-200E-06-06-F-00 FS2-200E-06-06-F-00 FS2-200E-06-06-F-00 FS2-200E-06-06-F-00 FS2-200E-06-06-F-00 FS2-200E-06-06-F-00 FS2-200E-06-06-F-00 FS2-200E-06-06-F-00 FS2-200E-06-06-F-00 FS2-200E-06-06-F-00 FS2-200E-06-06-F-00 FS2-200E-06-06-F-00 FS2-200E-06-06-F-00 FS2-200E-06-06-F-00 ,E 8.2.4-021 Rev 01 08/12 Top 130455634 130455634 130455634 130455641 130455641 130455641 130455641 130455641 130455640 130455640 130455640 130455640 130455640 130455639 130455639 130455639 130455629 130455629 130455629 130455629 130455629 130455620 130455620 130455620 130455620 130455620 130455620 130450180 130450180 130450180 130450180 Bottom 130455637 130455637 130455637 130455632 130455632 130455632 130455632 130455632 130455624 130455624 130455624 130455624 130455624 130455633 130455633 130455633 130455633 130455633 130443725 130443725 130443725 130455635 130455635 130455635 130455635 130455635 130455635 130455644 130455644 130455642 130455642 Manufacturing date Length 7/8/2013 7/8/2013 7/8/2013 7/10/2013 7/10/2013 7/10/2013 7/10/2013 7/10/2013 7/10/2013 7/10/2013 7/10/2013 7/10/2013 7/10/2013 7/10/2013 7/10/2013 7/10/2013 7/10/2013 7/10/2013 7/10/2013 7/10/2013 7/10/2013 7/10/2013 7/10/2013 7/10/2013 7/10/2013 7/10/2013 7/10/2013 7/10/2013 7/10/2013 7/10/2013 7/10/2013 270.00 270.00 226.00 270.00 270.00 270.00 270.00 270.00 270.00 270.00 270.00 270.00 270.00 270.00 270.00 270.00 270.00 270.00 270.00 270.00 270.00 270.00 270.00 270.00 270.00 270.00 270.00 270.00 270.00 270.00 270.00 Page 1 7/12/2013 09:54:05 am r 1 VIRONMENTAL' GSE Environmental, LLC Roll Allocation List les Order: SO-070563 Istomer Name: Plastic Fusion Fabricators, Inc. eject Name: PFF/Campbell Soup :vial number 31427942 31427943 31427944 31427945 31427946 31427947 31427948 31427949 31427950 31427951 31427952 31427953 31427954 31427955 31427956 31427957 31427960 31427961 31427962 31427963 31427964 31427965 31427966 31427967 31427968 31427969 31427970 31427971 31427972 31427973 31427974 Item Number FS2-200E-06=06-F-00 FS2-200E-06-06-F-00 FS2-200E-06-06-F-00 FS2-200E-06-06-F-00 FS2-200E-06-06-F-00 FS2-200E-06-06-F-00 FS2-200E-06-06-F-00 FS2-200E-06-06-F-00 FS2-200E-06-06-F-00 FS2-200E-06-06-F-00 FS2-200E-06-06-F-00 FS2-200E-06-06-F-00 FS2-200E-06-06-F-00 FS2-200E-06-06-F-00 FS2-200E-06-06-F-00 FS2-200E-06-06-F-00 FS2-200E-06-06-F-00 FS2-200E-06-06-F-00 FS2-200E-06-06-F-00 FS2-200E-06-06-F-00 FS2-200E-06-06-F-00 FS2-200E-06-06-F-00 FS2-200E-06-06-F-00 FS2-200E-06-06-F-00 FS2-200E-06-06-F-00 FS2-200E-06-06-F-00 FS2-200E-06-06-F-00 FS2-200E-06-06-F-00 FS2-200E-06-06-F-00 FS2-200E-06-06-F-00 FS2-200E-06-06-F-00 E 8.2.4-021 Rev 01 08/12 Top 130455621 130455621 130455621 130455621 130455621 130455621 130455619 130455619 130455619 130455619 130455619 130455622 130455622 130455622 130455622 130455622 130455645 130455645 130455645 130455645 130455645 130455636 130455636 130455636 130455636 130455636 130455638 130455638 130455638 130455638 130455638 Bottom 130455642 2022241221 2022241221 2022241221 2022241221 2022241221 130449653 130449653 130442496 2022505389 2022505389 2022505389 2022505389 130450298 130450298 130450348 130447635 130455623 130455623 130455643 130455643 130455643 130455643 130455643 130443736 2022505388 2022505388 2022505388 2022505388 2022505388 130443744 Manufacturing date Length 7/10/2013 7/10/2013 7/10/2013 7/10/2013 7/10/2013 7/10/2013 7/10/2013 7/10/2013 7/10/2013 7/10/2013 7/10/2013 7/10/2013 7/10/2013 7/10/2013 7/10/2013 7/10/2013 7/10/2013 7/10/2013 7/10/2013 7/10/2013 7/10/2013 7/10/2013 7/10/2013 7/10/2013 7/10/2013 7/10/2013 7/10/2013 7/10/2013 7/10/2013 7/10/2013 7/10/2013 270.00 270.00 270.00 270.00 270.00 270.00 270.00 270.00 270.00 270.00 270.00 270.00 270.00 270.00 270.00 270.00 270.00 270.00 270.00 270.00 270.00 270.00 270.00 270.00 270.00 270.00 270.00 270.00 270.00 270.00 270.00 Page 2 7/12/2013 09:54:05 am VIRONMENTAL GSE Environmental. LLC Roll Allocation List les Order: SO-070563 Istomer Name: Plastic Fusion Fabricators, Inc. Dject Name: PFF/Campbell Soup !dal number 31427975 31427976 31427977 31427978 31427979 31427980 31427981 31427982 31427983 31427984 31427985 31427986 31427987 31427988 31427989 31427990 31427991 31427992 31427993 31427994 31427995 31427996 31427997 31427998 31427999 31428000 31428001 31428002 31428003 31428004 31428005 Item Number FS2-200E-06-06-F-00 FS2-200E-06-06-F-00 FS2-200E-06-06-F-00 FS2-200E-06-06-F-00 FS2-200E-06-06-F-00 FS2-200E-06-06-F-00 FS2-200E-06-06-F-00 FS2-200E-06-06-F-00 FS2-200E-06-06-F-00 FS2-200E-06-06-F-00 FS2-200E-06-06-F-00 FS2-200E-06-06-F-00 FS2-200E-06-06-F-00 FS2-200E-06-06-F-00 FS2-200E-06-06-F-00 FS2-200E-06-06-F-00 FS2-200E-06-06-F-00 FS2-200E-06-06-F-00 FS2-200E-06-06-F-00 FS2-200E-06-06-F-00 FS2-200E-06-06-F-00 FS2-200E-06-06-F-00 FS2-200E-06-06-F-00 FS2-200E-06-06-F-00 FS2-200E-06-06-F-00 FS2-200E-06-06-F-00 FS2-200E-06-06-F-00 FS2-200E-06-06-F-00 FS2-200E-06-06-F-00 FS2-200E-06-06-F-00 FS2-200E-06-06-F-00 E 8.2.4-021 Rev 01 08/12 Top 2022505509 2022505509 2022505509 2022505509 2022505509 2022297271 2022297271 2022297271 2022297271 2022297271 2022450258 2022450258 2022450258 2022450258 2022450226 2022450226 2022450226 2022450226 2022450235 2022450235 2022450235 2022507645 2022507645 2022507645 2022507645 2022507645 2022509497 2022509497 2022509497 2022509497 2022509497 Bottom 130443744 130443744 2022450214 2022450214 2022450214 2022450214 2022450214 2022505504 2022505504 2022505504 2022505504 2022450162 2022450162 2022450162 2022450251 2022450251 2022450266 2022450266 2022450266 2022509491 2022509491 2022509491 2022509491 2022509491 2022505511 2022505511 2022505511 2022178160 2022178160 2022509493 2022509493 Manufacturing date Length 7/10/2013 7/10/2013 7/10/2013 7/10/2013 7/10/2013 7/10/2013 7/10/2013 7/10/2013 7/10/2013 7/10/2013 7/11/2013 7/11/2013 7/11/2013 7/11/2013 7/11/2013 7/11/2013 7/11/2013 7/11/2013 7/11/2013 7/11/2013 7/11/2013 7/11/2013 7/11/2013 7/11/2013 7/11/2013 7/11/2013 7/11/2013 7/11/2013 7/11/2013 7/11/2013 7/11/2013 270.00 270.00 270.00 270.00 270.00 270.00 270.00 270.00 270.00 270.00 270.00 270.00 270.00 270.00 270.00 270.00 270.00 270.00 270.00 270.00 270.00 270.00 270.00 270.00 270.00 270.00 270.00 270.00 270.00 270.00 270.00 Page 3 7/12/2013 09:54:05 am NVIRONMENTAL' GSE Environmental, LLC Roll Allocation List ;ales Order: SO-070563 :ustomer Name: Plastic Fusion Fabricators, Inc. 'roject Name: PFF/Campbell Soup Manufacturing aerial number Item Number Top Bottom date Length 131428006 FS2-200E-06-06-F-00 2022450252 20,22509493 7/11/2013 270.00 131428007 FS2-200E-06-06-F-00 2022450252 2022509493 7/11/2013 270.00 131428008 FS2-200E-06-06-F-00 2022450252 2022507643 7/11/2013 270.00 131428009 FS2-200E-06-06-F-00 2022507641 2022507643 7/11/2013 270.00 131428010 FS2-200E-06-06-F-00 2022507641 2022507643 7/11/2013 270.00 131428011 FS2-200E-06-06-F-00 2022507641 2022509492 7/11/2013 _ 270.00 131428012 FS2-200E-06-06-F-00 2022507641 2022509492 7/11/2013 270.00 131428013 FS2-200E-06-06-F-00 2022507641 2022509492 7/11/2013 270.00 131428014 FS2-200E-06-06-F-00 2022509494 2022509492 7/11/2013 270.00 131428015 FS2-200E-06-06-F-00 2022509494 2022470840 7/11/2013 270.00 131428016 FS2-200E-06-06-F-00 2022509494 2022470840 7/11/2013 270.00 131428017 FS2-200E-06-06-F-00 2022509494 2022470840 7/11/2013 270.00 131428018 FS2-200E-06-06-F-00 130455715 2022470840 7/11/2013 270.00 131428024 FS2-200E-06-06-F-00 130455715 130450195 7/11/2013 270.00 131428025 FS2-200E-06-06-F-00 130455715 130450195 7/11/2013 270.00 131428026 FS2-200E-06-06-F-00. 130455730 130450195. 7/11/2013 270.00 131428027 FS2-200E-06-06-F-00 130455730 '130450195 7/11/2013 270.00 131428028 FS2-200E-06-06-F-00 130455730 130450195 7/11/2013 270.00 131428029 FS2-200E-06-06-F-00 130455730 130455725 7/11/2013 270.00 131428030 FS2-200E-06-06-F-00 130455733 130455725 7/11/2013 270.00 131428031 FS2-200E-06-06-F-00 130455733 .130455725 7/11/2013 270.00 131428032 FS2-200E-06-06-F-00 130455733 130455725 7/11/2013 270.00 131428033 FS2-200E-06-06-F-00 130455733 130455725 7/11/2013 270.00 131428034 FS2-200E-06-06-F-00 130455733 130455731 7/11/2013 270.00 131428035 FS2-200E-06-06-F-00 130455728 130455731 7/11/2013 270.00 131428036 FS2-200E-06-06-F-00 130455728 130455731 7/11/2013 270.00 131428037 FS2-200E-06-06-F-00 130455728 130455731 7/11/2013 270.00 131428038 FS2-200E-06-06-F-00 130455728 130455731 7/11/2013 270.00 iSE 8.2.4-021 Rev 01 08/12 Page 4 7/12/2013 09:54:05 am GSE Environmental, LLC ENVIRONMENTAL ROLL TEST DATA REPORT Page 1 of 2 Report Date: Jul/12/2013 Sales Order No. Customer Name Project Location Product Name BOL Number SO-070563 Plastic Fusion Fabricators, Inc. Maxton , NC US FBR-060E-EBC-E-00 Roll Number Moss per ASTM ASTM ASTM Und Area 04491 ASTM ASTM ASTM ASTM ASTM 04533 04533 Puncture ASTM Water Flow 04491 . ASTM 04932 Grub D4932 Grub 04632 Grab 04932 Grab Trapezoidal Tmpezoidal Roslata cu D5281 Rate (ou d7 (9P 7 P� Irv) D4`5 ADS Sure) o l ength Ei(%) p Ebr,gatcn Taargbs) Toar9ps) ASTM 'fT (16) TD MO TD DOM pbs) 130442496 6.4 119 1.60 0.212 167 237 105 114 88 146 109 130443725 7.4 131 1.70 0.212 192 228 121 137 117 190 120 130443736 6.3 157 2.10 0.212 162 222 109 125 78 133 107 130443744 7.3 157 2.10 0.212 193 238 137 117 167 272 123 130447635 6.3 148 2.00 0.212 178 197 96 135 92 128 106 130449653 6.8 167 '2.20 0.212 204 206 77 116 128 134 1.18 130460180 8.4 149 2.00 0.212 228 245 104 123 1.19 187 141 130460195 8.8 131 1.80 0.212 207 255 102 126 115 153 147 130450298 6.7 174 2.30 0.212 179 173 94 148 102 127 125 130450348 7.2: 189 2.50 0.212 195 217 101 121 95 112 121 130455619 7.2 149 2.00 0.212 211 285 112 115 104 149 122 130455620 8.7 144 1.90 0.212 163 205 120 128 •93 154 104 130455621 6.7 144 1.90 0.212 163 205 120 128 93 '154 104 130455622 6.7 144 1.90 0.212 163 205 120 128 •93 154 104 130455623 6.7 144 1.90 0.212 163 205 120 128 93 154 104 130455624, 6.7 131 1.80 0.212 196 244 104 125 89 129 114 130455629 7.0 131 1.80 0.212 199 .256 104 124 91 . 142 113 130455632 6.6 131 1.80 0.212 192 233 100 126 93 122 119 130455633 6.6 131 1.80 0.212 192 233 100 • 126 93 122 119 130455634 6.6 131 1.80 0.212 192 233 100 126 93 122 119 130455635 6.6 131 1.80 0.212 192 233 ' 100 126 93 122 119 130455636 6.7 131 1.80 0.212 208 261 101 115 87 161 121 130455637 6.7 131 1.80 0.212 '208 261 101 115 87 161 121 130455638 6.7 131 1.80 0.212 208 261 101 115 87 161 121 130455639 6.7 131 . 1.80 0.212 208 261 101 115 87 161 121' 130455640 7.0 131 1.80 0.212 175 228 108 132 107 147 112 130455641 7.0 131 1.80 0.212 175 228 108 132 107 147 112 130455642 7.0 131 1.80 0.212 175 228 108 132 107 147 112 130455643 7.2 139 1.90 0.212 220 255 94 122 98 136 125 130455644 7.2 139 1.90 0.212 220 255 94 122 98 136 125 130455645 7.2 139 1.90 0.212 220 255 94 122 98 136 125 130455715 7.2 196 2.60 0.212 201 226 110 117 95 116 113 130455725 7.2 157 2.10 0.212 172 222 112 126 78 120 96 130455728 7.0 157 2.10 0,212 195 248 109 130 90 141 107 GSE Environmental, LLC ENVIRONMENTAL ROLL TEST DATA REPORT Page 2 of 2 Report Date: Jul/12/2013 Sales Order No. Customer Name Project Location Product Name BOL Number SO-070563 _ Plastic Fusion Fabricators, Inc. Maxton , NC US FBR-060E-EBC-E-00 Roll Number Mass per ASTM ASTM ASTM Unl Area 04401 ASTM ASTM ASTM ASTM ASTM D4533 D4533 Puncture ASTM Water Flow D4491 ASTM 046tr3n2�G11rohb 04632 Grab D4632 Grab D4632 Grab Trapezoidal Trapezoidal . Resistance D5261ASTM (�' Rate WWII') Permittivity D1(51 �) AOS ()bs) MD Sbonoth E(%)gMO E(�O Toar is) Ta TTD ) 04033 pbs) 130455730 7.0 157 2.10 0.212 195 248 109 130 90 141 107 130455731 7.0 157 2.10 0.212 195 248 109 130 90 141 107 130455733 6.6 157 2.10 0.212 184 216 105 139 91 123 126 Laboratory Manager This test report shall not be reproduced. except in full, without written approval of the laboratory.. 19103 Gundle Road - Houston, Texas 77073 GSE-8.2 4-029 Rev01 - - 02110 GSE Environmental, LLC ENVIRONMENTAL ROLL TEST DATA REPORT Page 1 of 4 Report Date:Jul/12/2013 Sales Order No. Customer Name Project Location Product Name BOL Number SO-070563 Plastic Fusion Fabricators, Inc. Maxton NC US FS2-200E-06-06-F-00 Roll Number Ply Carton Mammon Adhesion Ply Adiesgn Ply Adhesion gn Gae( Tensile Mock Amapa AverageMsern Minimum Thickness Strenplh Do, ( Golden! ASTM ASTM ASTM ASTM ASTM ASfl.1 ASTM ASTM D7005 (ppi) 07005 (ppi) 07015 ( ) D7005 (ppi) 05199 (mils) D7179 (pp) 01505 (g!s) 04218 OM side A Side B Slae A Side S 131427790 227 60 0.965 2.68 2.7 3.7 1.9 2.5 131427791 205 54 0.965 2.45 2.5 3.8 1.7 2.5 131427792 205 54 0.965 2.45 2.5 3.8 1.7 2.5 131427913 205 54 0.965 2.45 2.5 3.8 1.7 2.5 131427914 207 51 0.962 2.19 4.0 2.5 2.9 1.9 131427915 207 51 0.962 2.19 4.0 2.5 2.9 1.9 131427916 207 51 0.962 2.19 4.0 2.5 2.9 1.9 131427917 207 51 0.962 2.19 4.0 2.5 2.9 1.9 131427918 207 51 0.962 2.19 4.0 2.5 2.9 1.9 131427919 207 51 0.962 2.19 4.0 2.5 2.9 1.9 131427920 207 51 0.962 2.19 4.0 2.5 2.9 1.9 131427921 207 51 0.962 2.19 4.0 2.5 2.9 1.9 131427922 207 51 0.962 2.19 4.0 2.5 2.9 1.9 131427923 207 51 0.962 2.19 4.0 2.5 2.9 1.9 131427924 207 51 0.962 2.19 4.0 2.5 2.9 1.9 131427925 207 51 0.962 2.19 4.0 2.5 2.9 1.9 131427926 207 57 0.963 2.57 2.7 2.3 1.8 1.6 131427927 207 57 0.963 2.57 2.7 2.3 1.8 1.6 131427928 207 57 0.963 2.57 2.7 2.3 1.8 1.6 131427929 207 57 0.963 2.57 2.7 2.3 1.8 1.6 _ 131427931 207 57 0.963 2.57 2.7 2.3 1.8 1.6 131427932 207 57 0.963 2.57 2.7 2.3 1.8 1.6 131427933 207 57 0.963 2.57 2.7 2.3 1.8 1.6 131427934 • 207 57 0.963 2.57 2.7 2.3 1,8 1.6 131427935 207 57 0.963 2.57 2.7 2.3 1.8 1.6 131427936 207 57 0.963 2.57 2.7 2.3 1.8 1.6 131427937 207 57 0.963 2.57 2.7 2.3 1.8 1.6 131427938 205 51 0.965 2.55 2.4 3.2 1.8 2.3 131427939 205 51 0.965 2.55 2.4 3.2 1.8 2.3 131427940 205 51 0.965 2.55 2.4 3.2 1.8 2.3 131427941 205 51 0.965 2.55 2.4 3.2 1.8 2.3 131427942 205 51 0,965 2.55 2.4 3.2 1.8 2.3 131427943 205 51 0.965 2.55 2.4 3.2 1.8 2.3 131427944 205 51 0.965 2.55 2.4 3.2 1.8 2.3 GSE Environmental, LLC ENVIRONMENTAL ROLL TEST DATA REPORT /GSE� QC Page 2 of 4 Report Date: Jul/12/2013 Sales Order No. Customer Name Project Location Product Name BOL Number SO-070563 Plastic Fusion Fabricators, Inc. Maxton NC US FS2-200E-06-06-F-00 Roll Number Saone' Thickness ASTM SSID9 (mils) Tons is S h Dan AS7 AST D71784ppi) D1505 Ws) Cerb n ALLA t Adhayion Ply Adhesion ply Mhesion &arA Average Averogo Mirimum Mrtarmm Content ASTM ASTM ASTM ASTM ASTM 01005 07805(ppi) 07005 (pi) D7005(ppf) D4218(%) 54.A Stle9 SdoA Stle9 131427945 205 51 0.965 2.55 2.4 3.2 1.8 2.3 131427946 205 51 0.965 2.55 2.4 3.2 1.8 2.3 131427947 205 51 0.965 2.55 2.4 3.2 1.8 2.3 131427948 205 51 0.965 2.55 2.4 3.2 1.8 2.3 131427949 205 51 0.965 2.55 2.4 3.2 1.8 2.3 131427950 207 55 0.963 2.45 4.7 5.3 3.5 4.2 131427951 207 55 0.963 2.45 4.7 5.3 3.5 4.2 131427952 207 55 0.963 2.45 4.7 5.3 3.5 4.2 131427953 207 55 0.963 2.45 4.7 5.3 3.5 4.2 131427954 207 55 0.963 2.45 4.7 5.3 3.5 4.2 131427955 207 55 0.963 2.45 4.7 5.3 3.5 4.2 131427956 207 55 0.963 2.45 4.7 5.3 3.5 4.2 131427957 207 55 0.963 2,45 4.7 5.3 3.5 4.2 131427960 207 55 0.963 2,45 4.7 5.3 3.5 4.2 131427961 207 55 0.963 2.45 4.7 5.3 3.5 4.2 131427962 214 56 0.964 2.41 1.7 2.9 1.0 2.1 131427963 214 56 0.964 2.41 1.7 2.9 1.0 2.1 131427964 214 56 0.964 2.41 1.7 2.9 1.0 2.1 131427965 214 56 0.964 2.41 1.7 2.9 1.0 2.1 131427966 214 56 0.964 2.41 1.7 2.9 1.0 2.1 131427967 214 56 0.964 2.41 1.7 2.9 1.0 2.1 131427958 214 56 0.964 2.41 1.7 2.9 1.0 2.1 131427969 214 56 0.964 2.41 1.7 2.9 1.0 2.1 131427970 214 56 0.964 2.41 1.7 2.9 1.0 2.1 131427971 214 56 0.964 2.41 1.7 2.9 1.0 2.1 131427972 214 56 0.964 2.41 1.7 2.9 1.0 2.1 131427973 214 56 0.964 2.41 1.7 2.9 1.0 2.1 131427974 208 53 0.963 2.39 2.9 3.2 2.2 2.4 131427975 208 53 0.963 2.39 2.9 3.2 2.2 2.4 131427976 208 53 0.963 2.39 2.9 3.2 2.2 2.4 131427977 208 53 0.963 2.39 2.9 3.2 2.2 2.4 131427978 208 53 0.963 2.39. 2.9 3.2 2.2 2.4 131427979 208 53 0.963 2.39 2.9 3.2 2.2 2.4 131427980 208 53 0.963 2.39 2.9 3.2 2.2 2.4 GSE Environmental, LLC ENVIRONMENTAL ROLL TEST DATA REPORT Page 3 of 4 Report Date:JuV12/2013 Sales Order No. Customer Name Project Location Product Name BOL Number SO-070563 Plastic Fusion Fabricators, Inc. Maxton NC US FS2-200E-06-06-F-00 Roll Number Ply Carbon Adhesion A05onion WYAdhasion Ply Adhesion Gomel Tensile Black Average Aramga Miinnwn Mnkm m Thickness Strenngqtfh De00y Conlent ASTM . ASTM ASTM ASTM ASTM ASTM ASTM ASTM 07005(pp) 07005(pp) - D7005I 1 D7005 (pq) Mtn (eels) D7170 (pp) D1506 (g/m) D4218 (%) Side A Sid, B sld, A Side B 131427981 208 53 0.963 2.39 2.9 3.2 2.2 2.4 131427982 208 53 0.963 2.39 2.9 3.2 2.2 2.4 131427983 208 53 0.963 2.39 2.9 3.2 2.2 2.4 131427984 208 53 0.963 2.39 2.9 3.2 2.2 2.4 131427985 208 53 0.963 2.39 2.9 3.2 2.2 2.4 131427986 205 52 0.961 2.68 2.5 4.0 1.8 3.2 131427987 205 52 0.961 2.68 2.5 4.0 1.8 3.2 131427988 205 52 0.961 2.68 2.5 4.0 1.8 3.2 131427989 205 52 0.961 2.68 2.5 4.0 1.8 3.2 131427990 205 52 0.961 2.68 2.5 4.0 1.8 3.2 131427991 205 52 0.961 2.68 2.5 4.0 1.8 3.2 131427992 205 52 0.961 2.68 2.5 4.0 1.8 3.2 131427993 205 52 0.961 2.68 2.5 4.0 1.8 3.2 131427994 205 52 0.961 2.68 2.5 4.0 1.8 3.2 131427995 205 52 0.961 2.68 2.5 4.0 1.8 3.2 131427996 205 .52 0.961 2.68 2.5 4.0 1.8 3.2 131427997 205 52 0.961 2.68 2.5 4.0 1.8 3.2 131427998 209 56 0.963 2.46 4.7 5.8 3.7 4.3 131427999 209 56 0.963 2.46 4.7 5.8 3.7 4.3 131428000 209 56 0.963 2.46 4.7 5.8 3.7 4.3 131428001 209 56 0.963 2.46 4.7 5.8 3.7 4.3 131428002 209 56 0.963 2.46 4.7 5.8 3.7 4.3 131428003 209 56 0,963 2.46 4.7 5.8 3.7 4.3 131428004 209 56 0.963 2.46 4.7 5.8 3.7 4.3 131428005 209 56 0.963 2.46 4.7 5.8 3,7 4.3 131428006 209 56 0.963 2.46 4.7 5.8 3.7 4.3 131428007 209 56 0.963 2.46 4.7 5.8 3.7 4.3 131428008 209 56 0.963 2.46 4.7 5.8 3.7 4.3 131428009 209 56 0.963 2.46 4.7 5.8 3.7 4.3 131428010 210 61. 0.965 2.63 6.8 6.5 5.4 5.2 131428011 210 61 0.965 2.63 6.8 6.5 5.4 5.2 131428012 210 61 0.965 2.63 .. 6.8 6.5 5.4 5.2 131428013 210 61 0.965 2.63 6.8 6.5 5.4 5.2 131428014 210 61 0,965 2.63 6.8 6.5 5.4 5.2 GSE Environmental, LLC ENVIRONMENTAL ROLL TEST DATA REPORT Page 4 of 4 Report Date:Jul/12/2013 Sales Order No. Customer Name Project Location Product Name BOL Number SO-070563 Plastic Fusion Fabricators, Inc. Maxton NC US FS2-200E-06-06-F-00 Roll Number Ply Ply Carbon Adhesion A4hezlon trAte on Pry Adhesion Gemmel Temko Black Averapo Avempe Mewmum M n Thickness Stro�glh Den,�fy Coolant ASTM ASTM ASTM ASTM ASTM ASTM ABTM ASTM 07005 (ppi) D7005 (pail) D7005 (pp8 D7005(pp.) D5190 (mils) D7170 (ppi) D1505 (plcs) D4218 (%) Side A Side 9 Side A Side 8 131428015 210 61 0.965 2.63 6.8 6.5 5.4 5.2 131428016 210 61 0.965 2.63 6.8 6.5 5.4 5.2 131428017 210 61 0.965 2.63 6.8 6.5 5.4 5.2 131428018 210 61 0.965 2.63 6.8 6.5 5.4 5.2 131428024 210 61 0.965 2.63 6.8 6.5 5.4 5.2 131428025 206 55 0.963 2.37 5.2 4.6 4.3 3.8 131428026 206 55 0.963 2.37 5.2 4.6 4.3 3.8 131428027 206 55 0.963 2.37 5.2 4.6 4.3 3.8 131428028 206 55 0.963 2.37 5.2 4.6 4.3 3.8 131428029 206 55 0.963 2.37 5.2 4.6 4.3 3.8 131428030 206 55 0.963 2.37 5.2 4.6 4.3 3.8 131428031 206 55 0.963 2.37 5.2 4.6 4.3 3.8 131428032 206 55 0.963 2.37 5.2 4.6 4.3 3.8 131428033 206 55 0.963 2.37 5.2 4.6 4.3 3.8 131428034 206 55 0.963 2.37 5.2 4.6 4.3 3.8 131428035 206 55 0.963 2.37 5.2 4.6 4.3 3.8 131428036 206 55 0.963 2.37 5.2 4.6 4.3 3.8 .131428037 208 53 0.965 2.49 6.5 5.4 5.5 . 4.3 131428038 208 53 0.965 2:49 6.5 5.4 5.5 4.3 Laboratory Manager This test report shall not be reproduced, except in fun. without wed' en approval of.the laboratory. 19103 Gundte Road Houston, TX 77073 GSE-8.2.4-029 Rev01 - - 02/10 ENVIRONMENTAL Shipping Order - Packing List - Original - Not Negotiable GSE Environmental, LLC Kingstree, SC Pagel of2 Number BL-0073393 Received at KIngstmo, SC from GSE Lining Technology, LLC the property described below, in apparent good order, except as noted (contents and condition of packages unknown), marked, consigned, and destined as Indicated below, which said Camer agrees to carry to the place of delivery at said destination. It is mutually agreed as to each Carrier of all or any said property, over all or any portion of said route to destination, and as to each party at any time interested in all or any of said property, that every service performed hereunder shall be subject to the rates and contract agreed to in writing by GSE Lining Technology LLC and Carrier. GSE Lining Technology, LLC s obligation to pay freight charges far the shipment is conditioned on (1) the existence of a separate written contract with the carrier transporting the freight and (2) the carrier s name appearing on this Bill of Lading, and other carriers must look solely to a party other than GSE Lining Technology, LLC for payment Ship to: PFF/ Campbell's Soup Supply Company Ship date: Jul/12/2013 Maxton Plant 2120 N C Hwy 71 North Branch plant: 1503 Greg Westbrook 910-844-1331 Maxton, NC 28364 Sales order: SO-070563 Shipping instructions: 24 hr precall required - TRUCKS WILL NOT BE OFFLOADED WITHOUT PRECALL - DIRECTIONS ATTACHED Line no: Shipped quantity Product code UM Kind of Package, Description of Articles, Special Marko and Exceptions Weight Project 97,875 FS2-200E-06-06-F-00 SF FabriNet w/ 6 oz/yd2 MARV GSE Standard Material Freight charges are prepaid unless marked collect. 1 131427972 FabriNet w/ 6 oz/yd2 MARV GSE Standard Material 1,070.00 Check box if collect 2 131427977 FabriNet w/ 6 oz/yd2 MARV GSE Standard 1;060.00 Material 3 131427981 FabriNet w/ 6 oz/yd2 MARV GSE Standard 1,099.00 Customer PO number Material 4 131427982 FabriNet w/ 6 oz/yd2 MARV GSE Standard 1,058.00 Material P14709 5 131427983 FabriNet w/ 6 oz/yd2 MARV GSE Standard 1,056.00 Material If this shipment is to be 6 131427986 • FabriNet w/ 6 oz/yd2 MARV GSE Standard Material 1,092.00 delivered to'consignee, consignor shall sign the 7 131427.987 FabriNet w/ 6 oz/yd2 MARV GSE Standard 1,091.00 following statement. Material . 8 131427988 FabriNet w/ 6 oz/yd2 MARV GSE Standard Material 1,067.00 Carder may decline to deliver this shipment without payment 9 131427989 FabriNet w/ 6 oz/yd2 MARV GSE Standard Material 1,083.00 of freight and all other lawful charges.. 10 131427990 FabriNet w/ 6 oz/yd2 MARV GSE Standard 1,091.00 Material 11 131427991 FabriNet w/ 6 oz/yd2 MARV GSE Standard 1,079.00 Signature of Consignor 12 Material 131427992 FabriNet w/ 6 oz/yd2 MARV GSE Standard 1,070.00 Material 13 131427993 FabriNet w/ 6 oz/yd2 MARV GSE Standard 1,084.00 Local Verification Signed Material 14 131427994 FabriNet w/ 6 oz/yd2 MARV GSE Standard 1,084.00 Material 15 131427995 FabriNet w/ 6 oz/yd2 MARV GSE Standard 1,084.00 Material X . " 16 131427996 FabriNet w/ 6 oz/yd2 MARV GSE Standard 1,072.00 Material `17 131427997 FabriNet w/ 6 oz/yd2 MARV GSE Standard 1,075.00 PRO Number Material 18 131428002 FabriNet w/ 6 oz/yd2 MARV GSE Standard 1,064.00 KT039221 Material 19 131428003 FabriNet wl 6 oz/yd2 MARV GSE Standard 1,080.00 Seal numbers Material 20 131428004 FabriNet w/ 6 oz/yd2 MARV GSE Standard 1,036.00 Material Truckers P.O.* Total quantity: Total weight: P0660 Driver requirements: Carrier name Nesbitt Transportation, Inc. 1) Driver must pre call 24 hrs prior to delivery and on Friday for Monday delivery. 2) Driver must call (843) 201-1520 when unloaded. Carrier signature: 3) Driver must call and advise any delay in transit. 4) A copy of this bill of lading must accompany Freight Invoice. Date: GSE 7.5.5-007 CUSTOMER SERVICE REVO2 - Date 06/12/01 ENVIRONMENTALL' Shipping Order - Packing List - Original - Not Negotiable GSE Environmental, LLC Kingstree, SC Page2 of2 Number BL-0073393 Received at Kingstree, SC from GSE Lining Technology, LLC the property described below. in apparent good order, except as noted (contents and condition of packages unknown), marked, consigned, and destined as indicated below, which said Carrier agrees to carry to the place of delivery al said destination. It Is mutually agreed as to each Carrier of all or any said property. over alt or any portion of said rolJte to destination, and as to each party at any time interested in all or any of said property, that every service performed hereunder shall be subject 10 the rates and contract agreed to in writing by GSE Lining Technology, LLC and Carrier. GSE Lining,Technology, LLC s obligation to pay freight charges for the shipment Is conditioned on (1) the existence of a separate written contract with the carrier transporting the freight and (2) the carrier s name appearing on this Bill of Lading, and other carriers must look solely to a party other than GSE Lining Technology, LLC for payment. Ship to: PFF/ Campbell's Soup Supply Company Ship date: Jul/12/2013 Maxton Plant 2120 N C Hwy 71 North Branch plant: 1503 Greg Westbrook 910-844-1331 Maxton, NC 28364 . Sales order SO-070563 Shipping instructions: 24 hr precall required - TRUCKS WILL NOT BE OFFLOADED WITHOUT PRECALL - DIRECTIONS ATTACHED Line no. Shipped quantity Product code UM Kind of Package, Description of Articles, Special Marks and Exceptions Weight Project 21 22 23 24 25 26 1 FREIGHTDRN001 EA 131428005 FabriNet w/ 6 oz/yd2 MARV GSE Standard Material 131428006 FabriNet w/ 6 oz/yd2 MARV GSE Standard Material 131428007 FabriNet w/ 6 oz/yd2 MARV GSE Standard Material 131428008 FabriNet w/ 6 oz/yd2 MARV GSE Standard Material 131428031 FabriNet w/ 6 oz/yd2 MARV GSE Standard Material DOM. SHIPPING CHARGE DOM. SHIPPING CHARGE 1,099.00 1;098.00 1,097.00 1,086.00 1,086 00 0 00 • Freightchargesprepaid are re aid unless marked collect. Check box if collect Customer PO number P14709 If this shipment Is to be delivered to consignee. consignor shall sign the following statement. Carder may decline to deliver this shipment without payment of freight and all other lawful charges; Signature of Consignor Local VerificationSigned X PRO Number KT039221 Seal numbers Truckers P.O. # P0650 Total quantity: 97,876 Total weight: 26,961.00 Driver requirements: Carrier name: 1) Driver must pre call 24 hrs prior to delivery and on Friday for Monday delivery. 2) Driver must call (843) 201-1520 when unloaded. Carrier signature: 3) Driver must call and advise any delay in transit. 4) A copy of this bill of lading must accompany Freight Invoice. Date: Nesbitt Transportation, Inc. GSE 7.5.5-007 CUSTOMER SERVICE REVO2 -.Date 06/12/01 ENVIRONMENTAL" Shipping Order - Packing List - Original - Not Negotiable GSE Environmental, LLC Kingstree, SC Pagel of2 Number BL-0073399 Received at Kingstree, SC from GSE Lining Technology, LLC the property described below, in apparent good order, except as noted (contents and condition of packages unknown), marked, consigned. and destined as indicated below,.whlch said Caller agrees to carry to the place of delivery at said destination. It is mutually agreed as to each Carrier of all or any said property, over all or any portion of said route to destination, and as to each party at any tame interested in all or any of said property, that every service performed hereunder shall be subject to the rates and contract agreed to in writing by GSE Lining Technology, LLC and Carrier. GSE Liming Technoogy, LLC s obligation to pay freight charges for the shipment is conditioned on (1) the existence of a separate written contract with the carrier transporting the freight and (2) the carrier s name appearing on this Bill of Lading, and other carriers must look solely to a party other than GSE Lining Technology, LLC for payment Ship to: PFF/ Campbell's Soup Supply Company Ship date: Jul/15/2013 Maxton Plant 2120 N C Hwy 71 North Branch plant: 1503 .Greg Westbrook 910-844-1331 Maxton, NC 28364 Sales order: SO-070563 Shipping instructions: '24 hr precall required - TRUCKS WILL NOT BE OFFLOADED WITHOUT PRECALL - DIRECTIONS ATTACHED Line no. Shipped quantity Product code UM Kind of Package, Description of Articles, Special Marks and Exceptions Weight Project 93,960 FS2-200E-06-06-F-00 SF FabriNet w/ 6 oz/yd2 MARV GSE Standard Material Freight charges are prepaid unless marked collect. 1 131427954 FabriNet w/ 6 ozJyd2 MARV GSE Standard Material 1,074.00 Check box if collect 2 131427960 FabriNet w/ 6 oz/yd2 MARV GSE Standard 1,065.00 Material 3 131427961 FabriNet w/ 6 oz/yd2 MARV GSE Standard 1,066.00 Customer PO number Material 4 131427962 FabriNet w/ 6 oz/yd2 MARV GSE Standard 1,081.00 Material P14709 5 131427963 FabriNet w/ 6 oz/yd2 MARV GSE Standard 1,089.00 Material If this shipment Is to he 6 . . 131427964 FabriNet w/ 6 oz/yd2 MARV GSE Standard Material 1,090.00 delivered to consignee, consignor shall sign the 7 131427965 FabriNet w/ 6 oz/yd2 MARV GSE Standard 1,079.00 following statemen( . Material 8 131427966 FabriNet w/ 6 oz/yd2 MARV GSE Standard Material 1,068.00 Carrier may decline to deliver this shipment without payment 9 131427967 FabriNet w/ 6 oz/yd2 MARV GSE Standard -Material 1,096.00 of freight and all other lawful charges. . 10 , 131427968 FabriNet w/ 6 oz/yd2 MARV GSE Standard Material 1,070.00 11 131427969 FabriNet w/ 6 oz/yd2 MARV GSE Standard 1,052.00 Signature of Consignor 12 Material 131427970 FabriNet w/ 6 oz/yd2 MARV GSE Standard 1,035.00 Material 13 131427971 FabriNet w/ 6 oz/yd2 MARV GSE Standard 1,072,00 Local Verification Signed Material 14 131427973 FabriNet w/ 6 oz/yd2 MARV GSE Standard 1,066.00 Material 15 131427974 FabriNet wl 6 oz/yd2 MARV GSE Standard 1,067.00 Material X 16 131427975 FabriNet w/ 6 oz/yd2 MARV GSE Standard . 1,068.00 Material 17 131427976 FabriNet w/ 6 oz/yd2 MARV GSE Standard 1,074.00 PRO Number Material 18 131427978 FabriNet wl 6 oz/yd2 MARV GSE Standard 1,074.00 KT039222 Material 19 131427979 FabriNet w/ 6 oz/yd2 MARV GSE Standard 1,080.00 Seal numbers Material 20 131427980 FabriNet w/ 6 oz/yd2 MARV GSE Standard 1,102.00 Material Truckers P.O. # Total quantity: Total weight: P0650 Driver requirements: Carrier name: Nesbitt Transportation, Inc.1) Driver must pre call 24 hrs prior to delivery and on Friday for Monday delivery. 2) Driver must call (843) 201-1520 when unloaded. Carrier signature: 3) Driver must call and advise any delay in transit. . 4) A copy of this bill of lading must accompany Freight Invoice. Date: GSE 7.5.5-007 CUSTOMER SERVICE REVO2 — Dale 06/12101 Shipping Order - Packing List - Original - Not Negotiable GSE Environmental, LLC Kingstree, SC ENVIRONMENTAL Page2 oft Number BL-0073399 Received at KIngstnrne, SC from GSE Lining Technology, LLC the property described below, in apparent good order, except as noted (contents and condition of packages unknown), marked, consigned, and destined as indicated below, which said Carrier agrees to carry to the place of delivery at said destination, It is mutually agreed as to each Carrier of all or any said property, over all or any portion of said route to destination, and as to each party at any time interested in all or any of said property, that every service performed hereunder shall be subject to the rates and contract agreed to in writing by GSE Lining Technology; LLC and Carrier, GSE Lining Technology, LLC s obligation to pay freight charges for the shipment is conditioned on (1) the existence of a separate written contract with the carrier transporting the freight and (2) the carrier s name appearing on this Bill of Lading, and other carriers must look solely to a party other than GSE Lining Technology,,LLC for payment Ship to: PFF/ Campbell's Soup Supply Company Ship date: Jul/15/2013 Maxton Plant . 2120 N C Hwy 71 North Branch plant: 1503 Greg Westbrook 910-844-1331 Maxton, NC 28364 Sales order: SO-070563 Shipping instructions: 24 hr precall required - TRUCKS WILL NOT BE OFFLOADED WITHOUT PRECALL - DIRECTIONS ATTACHED Line no. Shipped quantityExceptions, Product code UM Kind of Package, Description of Articles, Special Marks and Weight Project 21 22 23 24 25 1 FREIGHTDRN001 EA 131427984 FabriNet w/ 6 oz/yd2 MARV GSE Standard Material 131427985 FabriNet w/ 6 oz/yd2 MARV GSE Standard Material 131427998 FabriNet w/ 6 oz/yd2 MARV GSE Standard Material 131428010 FabrNet w/ 6 oz/yd2 MARV GSE Standard Material DOM. SHIPPING CHARGE DOM. SHIPPING CHARGE 1,042.00 1,078.00 1,075.00 1,042,00 ' 0.00 are Freight charges g 9 prepaid unless marked collect. Check box if collect Customer PO number P14709 . If this shipment is to be • delivered to consignee, - consignor shall sign the fallowing staterrient.. Carder may decline to deliver this shipment withoutpayment of freight and all other lawful charges: - Signature of Consignor Local Verification Signed X PRO Number KT039222' Seal numbers Truckers P.O. # P0650 Total quantity: 93,961 Total weight: 25,705.00 Driver requirements: Carrier name: Driver must pre call 24 hrs prior to delivery and on Friday for Monday delivery. 2) Driver must call (843) 201-1520 when unloaded. Carrier signature: 3) Driver must call and advise any delay in transit. 4) A copy of this bill of lading must accompany Freight Invoice. Nesbitt Transportation, Inc.1) Date: GSE 7.5.5-007 CUSTOMER SERVICE REVO2 - Date 06/12/01 ENVIRONMENTAL". Shipping Order - Packing List - Original - Not Negotiable GSE Environmental, LLC Kingstree, SC Pagel oft Number BL-0073412 Received at Kingstree, SC from GSE Lining Technology, LLC the property described below, in apparent good order, except as noted (contents and condition of packages unknown), marked, consigned, and destined as indicated below, which said Carrier agrees to carry to the place of delivery at said destination, It Is mutually agreed as to each Carrier of all or any said property over all or any portion of said route to destination, and as to each party at any time interested in all or any of said property, that every service performed hereunder shall be subject to the rates and contract agreed to in writing by GSE Lining Technology, LLC and Carrier. GSE Lining Technology, LLC s obligation to pay freight charges for the shipment is conditioned on (1) the existence of a separate written contract with the carrier transporting the freight and (2) the carrier s name appearing on this Bill of Lading, and other carriers must look solely 10 a party other than GSE Lining Technology, LLC for payment. Ship to: PFF/ Campbell's Soup Supply Company Maxton Plant 2120 N C Hwy 71 North Greg Westbrook 910-844-1331 Maxton, NC 28364 Ship date: Jul/15/2013 Branch plant: 1503 Sales order: SO-070563 Shipping instructions: 24 hr precall required - TRUCKS WILL NOT BE OFFLOADED WITHOUT PRECALL- DIRECTIONS ATTACHED Line no. Shipped quantity Product code UM Kind of Package, Description of Articles, Special Marks and Exceptions Weight Project 93,322 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 FS2-200E--06-06-F-00 SF FabriNet w/ 6 oz/yd2 MARV GSE Standard Material 131427790 FabriNet w/ 6 oz/yd2 MARV GSE Standard Material 131427791 FabriNet w/ 6 oz/yd2 MARV GSE Standard Material 131427792 FabriNet w/ 6 ozlyd2 MARV GSE Standard Material 131427913 FabriNet w/ 6 ozlyd2 MARV GSE Standard Material 131427914 FabriNet w/ 6 ozlyd2 MARV GSE Standard Material 131427915 FabriNet w/ 6, ozlyd2 MARV GSE Standard Material 131427916 FabriNet wl 6 oz/yd2 MARV GSE Standard Material 131427917 FabriNet w/ 6 oz/yd2 MARV GSE Standard Material 131427918 FabriNet w/ 6 ozlyd2 MARV GSE Standard Material 131427919 FabriNet w/ 6 oz/yd2 MARV GSE Standard Material 131427920 FabriNet w/ 6 oz/yd2 MARV GSE Standard Material 131427921 FabriNet w/ 6 oz/yd2 MARV GSE Standard Material 131427922 FabriNet w/ 6 ozlyd2 MARV GSE Standard Material 131427923 FabriNet wl 6 ozlyd2 MARV GSE Standard Material 131427924 FabriNet w/ 6 ozlyd2 MARV GSE Standard Material 131427925 FabriNet w/ 6 oz/yd2 MARV GSE Standard Material 131427926 FabriNet w/ 6 ozlyd2 MARV GSE Standard Material 131427927 FabriNet w/ 6 oz/yd2 MARV GSE Standard Material 131427928 FabriNet w/ 6 oz/yd2 MARV GSE Standard Material 131427929 FabriNet w/ 6 ozlyd2 MARV GSE Standard Material 1,170.00. 1,160.00 971.00 1,063.00 1,073.00 1,070.00 1,066.00 1,072.00 1,070.00 1,071.00 1,074.00 1,076.00 1,074.00 1,073.00 1,072.00 1,080.00 1,073.00 1,075.00 1,071.00 1,075.00 Freight charges are prepaid unless marked collect. Check box if collect Customer PO number P14709. If this shipment is to be delivered to consignee, - consignor shall sign the following statement. Carder may decline to deriver this shipment without payment of freight and.all other lawful charges. Signature of Consignor Local Verification Signed PRO Number KT039224 Seal numbers Total quantity: Total weight: Truckers P.O. # P0650 Driver requirements: 1) Driver must pre call 24 hrs prior to delivery and on Friday for Monday delivery. 2) Driver must call (843) 201-1520 when unloaded. 3) Driver must call and advise any delay in transit. 4) A copy of this bill of lading must accompany Freight Invoice. Carrier name: Nesbitt Transportation, Inc. Carrier signature: Date: GSE 7.5.5-007 CUSTOMER SERVICE REVO2 - Date 06/12/01 ENVIRONMENTAL" Shipping Order - Packing List - Original - Not Negotiable GSE Environmental, LLC Kingstree, SC Page2 of2 Number BL-0073412 Received at Kingstree, SC from GSE Lining Technology, LLC the property described below, in apparent good order, except as noted (contents and condition of packages unknown), marked, consigned, and destined as indicated below, which said Carrier agrees to carry to the place of delivery al said destination. It is mutually agreed as to each Carder of all or any said property, over all or any portion of said route to destination, and as touch party at any time Interested In all or any of said property, that every service performed hereunder shall be subject to the rates and contract agreed to in writing by GSE Lining Technology LLC and Carrier. GSE Lining Technology, LLC s obligation to pay freight charges for the shipment is conditioned on (1) the existence of a separate written contract with the carrier transporting the height and (2) the camper s name appearing on this Bill of Lading, and other carriers must look solely to a party other than GSE Lining Technology, LLC for payment. Ship to: PFF/ Campbell's Soup Supply Company Ship date: Jul/15/2013 Maxton Plant 2120 N C Hwy 71 North Branch plant: 1503 Greg Westbrook 910-844-1331 Maxton, NC 28364 Sales order: SO-070563 Shipping instructions: 24 hr precall required - TRUCKS WILL NOT BE OFFLOADED WITHOUT PRECALL - DIRECTIONS ATTACHED Line Shippedtt quantity Product code UM Kind of Package, Description of Articles, Special Marks and Exceptions weight Project 21 22 23 24 25: 1 FREIGHTDRN001 EA 131427931 FabriNet wl 6 oz/yd2 MARV GSE Standard Material 131427932 FabriNet w/ 6 oz/yd2 MARV GSE Standard Material 131428017 FabriNet w/ 6 oz/yd2 MARV GSE Standard Material 131428027 FabriNet w/ 6 oz/yd2 MARV GSE Standard Material DOM. SHIPPING CHARGE DOM. SHIPPING CHARGE 1,072.00 1,073.00 1,107.00 1,127.00 0.00 are Freight charges g 9 prepaid unless marked collect. Check box if collect Customer PO number P14709 If this shipment is to be delivered to consignee, _ . . consignor shall sign the following statement. Carrier may decline to deliver this shipment without payment of freight and ail other lavrfut charges.. Signature of Consignor. Local Verification Signed. X PRO Number KT039224 Seal numbers Truckers P.O..# P0650 Total quantity: 93,323 Total weight: 25,908.00 Driver requirements: Carrier name: 1) Driver must pre call' 24 hrs prior to delivery and on Friday for Monday delivery. 2) Driver must call (843) 201-1520 when unloaded. Carrier signature: 3) Driver must call and advise any delay in transit. 4) A copy of this bill of lading must accompany Freight Invoice. Nesbitt Transportation, Inc. Date: GSE 7.5.5-007 CUSTOMER SERVICE REVO2 - Date 06/12/01 ENVIRONMENTAL Shipping Order - Packing List - Original - Not Negotiable GSE Environmental, LLC. Houston, TX Pagel ofl Number BL-0073416 Received at Houston, TX from GSE Lining Technology, LLC the property described below, In apparent good order, except as noted (contents and condition of packages unknown), marked, consigned, and destined as indicated below, which said Carrier agrees to carry to the place of delivery at said destination, 11 is mutually agreed as to each Cartier of all or any said property, over all or any portion of said route to destination, and as to each party al any lime Interested in all or any of said property, that every service performed hereunder shall be subject to the rates and contract agreed to in writing by GSE Lining Technology, LLC and Carrier_ GSE Lining Technology; LLC s obligation to pay freight charges for the shipment is conditioned on (1) the existence of a separate written contract with the carrier transporting the freight and (2) the carrier s name appearing on thls Bill of Lading. and other carriers must look solely to a party other than GSE Lining Technology, LLC for paymenL Ship to: PFF/ Campbell's Soup Supply Company Ship date: JuI/15/2013 Maxton Plant 2120 N C Hwy 71 North Branch plant: 1500 Greg Westbrook 910-844-1331 Maxton, NC 28364 Sales order: SO-070563 Shipping instructions: 24 hr precall required - TRUCKS WILL NOT BE OFFLOADED WITHOUT PRECALL - DIRECTIONS ATTACHED Line no. Shipped quantity Product code UM Kind of Package, Description of Articles, Special Marks and Exceptions Weight Project 151,200 HDS-060AE-WBB-B-00 SF GSE HD 060 mil Avg White 22.5' Freight charges are prepaid unless marked collect. 1 105167939 GSE HD 060 mil Avg White 22.5' 3,782.00 2 105167947 GSE HD 060 mil Avg White 22.5' 3'772'00 Check box if collect 3 105167950 GSE HD 060 mil Avg White 22.5' 3,752.00 4 105167951 GSE HD 060 mil Avg White 22.5' 3,748.00 5 105167955 GSE HD 060 mil Avg White 22.5' 3,880.00 Customer PO number 6 105167956 GSE HD 060 mil Avg White 22.5' 3,886.00 P14709 7 105167957 GSE HD 060 mil Avg White 22.5' 3,890 00 8 105167960 GSE HD 060 mil Avg White 22.5' 3,770.00 If this shipment is to be delivered to co 9 105167961 GSE HD 060 rail Avg White 22.5' 3,774.00 consignor shall sign the following statement. 10 • 105167962 GSE HD 060 mil Avg White 22.5' 3,772.00 Carder may decline to deliver 11 105167963 • GSE HD 060 mil Avg White 22.5' 3,760.00 this shipment without payment of freight and all other lawful 12 105167964 GSE HD 060 mil Avg White 22.5' 3,754.00 charges. 1 FREIGHTSHT001 EA DOM. SHIPPING CHARGE 13 DOM. SHIPPING CHARGE 0.00 Signature of Consignor Local Verification Signed X PRO Number RR047285 Seal numbers Truckers P.O. # Total quantity: 151,201 Total weight: 45,540.00 P02450 Driver requirements: Carrier name: Global Tranz 1) Driver must pre call 24 hrs prior to delivery and on Friday for Monday delivery. 2) Driver must call (281) 230-6781 when unloaded. Carrier signature: 3) Driver must call and advise any delay in transit. 4) A copy of this bill of lading must accompany Freight Invoice. Date: GSE 7.5.5-007 CUSTOMER SERVICE REVO2 — Date 06/12/01 L_. Shipping Order - Packing List - Original - Not Negotiable GSE Environmental, LLC Houston, TX ENVIRONMENTAL" Pagel ofl Number BL-0073422 Received at Houston, TX from GSE Lining Technology, LLC the property described below, In apparent good order, except as noted (contents and condition of packages unknown), marked, consigned, and destined as indicated below, which said Carrier agrees to carry to the place of delivery at said destination It is mutually agreed as to each Carrier of all or any said property, over all or any portion of said route to destination; and as to each party at any time interested in all or any of said property, that every service performed hereunder shall be subject to the rates and contract agreed to in writing by GSE Lining Technology, LLC. and Carrier, :GSE Lining Technology, LLC s obligation to pay freight charges for the shipment is conditioned on (1) the existence of a separate written contract with the carrier transporting the freight and (2) the carrier s name appearing on this Bill of Lading, and other tamers must look solely to a party other than GSE Lining Technology, LLC for payment. Ship to: PFF/ Campbell's Soup Supply Company Ship date: Jul/15/2013 Maxton Plant 2120 N C Hwy 71 North Branch plant: 1500 Greg Westbrook 910-844-1331 Maxton, NC 28364 Sales order: SO-070563 Shipping instructions: 24 hr precall required - TRUCKS WILL NOT BE OFFLOADED WITHOUT PRECALL - DIRECTIONS ATTACHED Line no, Shipped quantity Product code U M Kind of Package, Description of Articles, Special Marks and Exceptions Weight Project 151,200 HDS-060AE-WBB-B-00 SF GSE HD 060 mil Avg White 22.5' Freight charges are prepaid unless marked collect. 1 105167938 GSE HD 060 mil Avg White 22.5' 3,774,00 2 105167940 GSE HD 060 mil Avg White 22.5' 3,784.00 Check box if collect 3 . 105167941 GSE HD 060 mil Avg White 22.5' 3,780.00 4 105167942 GSE HD 060 mil Avg White 22.5' 3,790.00 5 105167943 GSE HD 060 mil Avg White 22.5' 3,778.00 Customer PO number 6 105167944 GSE HD 060 mil Avg White 22.5' 3,774.00 P14709 7 105167945 GSE HD 060 mil Avg White 22.5' 3,782 00 8 9 105167946 GSE HD 060 mil Avg White 22.5' 105167948 ' GSE HD 060 mil Avg White 22.5' 3,770.00 3,764.00 It this shipment is to be delivered to consignee, consignor shall sign the following statement. 10 105167949 GSE HD 060 mil Avg White 22.5' 3,754.00 Carrier may decline to deliver 11 105167958 GSE HD 060 mil Avg White 22.5' 3,826.00 this shipment without payment 12 105167959 GSE HD 060 mil Avg White 22.5' 3,780.00 of freight cargeall S.her lawful 0 1 FREIGHTSHT001 EA DOM. SHIPPING CHARGE 13 DOM. SHIPPING CHARGE 0.00 Signature of Consignor Local Verification Signed X PRO Number. ; RR047286 Seal numbers Truckers P.O. # Total quantity: 151,201 - Total weight: 45,356.00 P02450 Driver requirements: Carrier name: Global Tranz 1) Driver must pre call 24 hrs prior to delivery and on Friday for Monday delivery. 2) Driver must call (281) 230-6781 when unloaded. Carrier signature: 3) Driver must call and advise any delay In transit. 4) A copy of this bill of lading must accompany Freight Invoice. Date: GSE 7.5.5-007 CUSTOMER SERVICE REVO2 - Date 06/12/01 ENVIRONMENTAL" Shipping Order - Packing List - Original - Not Negotiable GSE Environmental, LLC Houston, TX Pagel ofl Number BL-0073452 Received at Houston, TX from GSE Lining Technology, LLC the property described below, in apparent good order, except as noted (contents and condition of packages unknown), marked, consigned, and destined as Indicated below, which said Carrier agrees to carry to the place of delivery at said destination. It is mutually agreed as to each Cartier of all or any said property, over all or any portion of said route to destination, and as to each party at any time Interested in all or any of said property, that every service performed hereunder shall be subject to the rates and contract agreed to in writing by GSE Lining Technology, LLC and Carrier. GSE Lining Technology, LLC s obligation to pay freight charges for the shipment is conditioned on (1) the existence of a separate written contract with the carder transporting the freight and (2) the carrier s name appearing on this Bill of Lading and other carriers must look solely to a party other than GSE Lining Technology, LLC for payment Ship to: PFF/ Campbell's Soup Supply Company Ship date: Jul/16/2013 Maxton Plant 2120 N C Hwy 71 North ' Branch plant: 1500 Greg Westbrook 910-844-1331 Maxton, NC 28364 Sales order: SO-070563 Shipping instructions: 24 hr precall required - TRUCKS WILL NOT BE OFFLOADED WITHOUT PRECALL - DIRECTIONS ATTACHED Line no. Shipped quantity Product code UM Kind of Package, Description of Articles, Special Marks and Exceptions Weight Project 151,200 HDS-060AE-WBB-B-00 SF GSE HD 060 mil Avg White 22.5' Freight charges are prepaid unless marked collect. 1 105167968 GSE HD 060 mil Avg White 22.5' 3,824.00 2 105167969 GSE HD 060 mil Avg White 22.5' 3,862.00 Check box if collect 3 105167970 GSE HD 060 mil Avg White 22.5' 3,832.00 4 105167971 GSE HD 060 mil Avg White 22.5' 3,742.00 5 105167972 GSE HD 060 mil Avg White 22.5'. 3,820.00 Customer PO number 6 105167973 GSE HD 060 mil Avg White 22.5' 3,798.00 P14709 7 105167977 GSE HD 060 mil Avg White 22.5' 3,828 00 8 9 105167985 GSE HD 060 mil Avg White 22.5' ' 105167986 GSE HD 060 rail Avg White 22.5' 3,818.00 3,752.00 If this shipment is to be delivered to consignee, - consignor shall sign the following statement. 10 105167989 GSE HD 060 mil Avg White 22.5' 3:920.00 Carrier may decline to deliver 11 105167990 GSE HD 060 mil Avg White 22.5' 3,886.00 this shipment withoutpayment of freight and alt other lawful 12 105167991 GSE HD 060 mil Avg•White 22.5' 3,734.00 charges. 1 FREIGHTSHT001 EA DOM. SHIPPING CHARGE 13' DOM. SHIPPING CHARGE 0.00 Signature of Consignor Local Verification Signed X PRO Number RR047287' Seal numbers Truckers P.O. # Total quantity: 151,201 Total weight: 45,816.00 P02450 Driver requirements: Carrier name: Global Tranz 1) Driver must pre call 24 hrs prior to delivery and on Friday for Monday delivery. 2) Driver must call (281) 230-6781 when unloaded. Carrier signature: 3) Driver must call and advise any delay in transit. 4) A copy of this bill of lading must accompany Freight Invoice. Date: GSE 7.5.5-007 CUSTOMER SERVICE REVO2 - Date 06/12/01