Loading...
HomeMy WebLinkAboutWQ0042501_Variance Request Approval_20221021 DocuSign Envelope ID:30C22255-9E91-4E5D-B61C-0A385F833A02 ROY COOPER P,s li���� x w Governor a`� ;4,. �i t S. ELIZABETH S.BISER •it q".� , - Secretary . RICHARD E.ROGERS,JR. NORTH CAROLINA Director Environmental Quality October 21, 2022 Jeff Theberge, P.E., Engineering Manager Cape Fear Public Utility Authority 235 Government Center Drive Wilmington, NC 28403 Subject: Variance Request Approval Cape Fear Public Utility Authority Wilmington Three Apartments Public Sewer (WQ0042501) New Hanover County Dear Mr.Theberge: The Division of Water Resources (Division) has reviewed the submitted variance request received on August 10, 2022 for the subject project. The Division will grant the variance request for the use of one interference box, as indicated on the provided plans; subject to the following requirements in accordance with the provisions for alternative design under 15A NCAC 02T.0105(n): 1. Pursuant to the variance request received from Paramounte Engineering, Inc. on behalf of Cape Fear Public Utility Authority, a variance is granted for the operation of approximately 40 linear feet of 8-inch gravity sewer within an interference box at STA 10+20 on Breezewood Drive. 2. Gravity sewer lines suspended through conflict/interference boxes to resolve intersections with storm drains shall be constructed of ductile iron pipe with mechanical joints, utilizing the materials,testing methods, and acceptability standards meeting water main standards, in accordance with 15A NCAC 02T.0305(g). These lines shall be designated as high-priority sewers, subject to the conditions as outlined below: a. The section of gravity sewer as described above shall be designated as "high- priority sewer" in accordance with 15A NCAC 02T.0402. , b. High-priority sewers shall be inspected by the permittee or its representative at least once every six-months in accordance with the permittee's individual system-wide collection system permit (WQCS00012). Regardless of the variance approval, in the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions,the Permittee shall take � North Carolina Depm of im Q Divis N Rs ��� 512 Nortlr Salisbury Sarttreetent I1611Env Maironl Service CenualityierI I Raletphionof Northater Carolinaesource 27 699-1611 NORM cn`nx INA D 919 707 9000 Department of m.o-mnwsi m,an DocuSign Envelope ID:30C22255-9E91-4E5D-B61C-0A385F833A02 immediate corrective action, including those as may be required by this Division,such as the construction of additional or replacement facilities. All other elements of this project shall be constructed in accordance with all applicable rules and statues including, 15A NCAC 2T;the Division of Water Resources' (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; and the Division's Minimum Design Criteria for the Fast-Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable. Approval of the variance request does not constitute approval of the permit. If you have any questions,please contact Charlie Miller, P.E. at(919) 707-3627 or by email at Charlie.Miller(@,ncdenr.gov. Sincerely, DocuSigned by: C . o C464531431644FE... for Richard E. Rogers,Jr. Director,Division of Water Resources by Michael Montebello NPDES Branch Chief,Division of Water Resources,DEQ CC: Daniel Fisk, P.E.,Paramounte Engineering, Inc. (dfisk@paramounte-eng.com) Wilmington Regional Office,Water Quality Regional Operations Municipal Permitting Unit(electronic copy) partment ironm Q I s Wrces � North 512 NorthCarolina SalisbuDery Street I of1611Env Matl Serviceental Centeruality I Divi Raletghionof Northater CaroResoulina 27699-1611 rmitn I CARD,NnD ar.n> +avi�ft / 919 707.9000