HomeMy WebLinkAboutSW6221003_O&M Agreement/Plan_20221018Operation & Maintenance Agreement
Project Name:
Project Location:
Carolina Wildlife Conservation Park
1096 Patterson Road -Harnett County, NC
Cover Page
Maintenance records shall be kept on the following SCM(s). This maintenance record shall be kept in a log in a known set location.
Any deficient SCM elements noted in the inspection will be corrected, repaired, or replaced immediately. These deficiencies can
affect the integrity of structures, safety of the public, and the pollutant removal efficiency of the SCM(s).
The SCM(s) on this project include (check all that apply & co
Infiltration Basin
Quantity:
Infiltration Trench
Quantity:
Bioretention Cell
Quantity:
Wet Pond
Quantity:
Stormwater Wetland
Quantity:
Permeable Pavement
Quantity:
Sand Filter
Quantity:
Rainwater Harvesting
Quantity:
Green Roof
Quantity:
Level Spreader - Filter Strip
Quantity:
Proprietary System
Quantity:
Treatment Swale
Quantity:
Dry Pond
Quantity:
Disconnected Impervious Surface
Present:
User Defined SCM
Present:
Low Density
Present:
onding O&M sheets will
Location(s):
Location(s):
Location(s):
Location(s):
Location(s):
Location(s):
Location(s):
Location(s):
Location(s):
Location(s):
Location(s):
Location(s):
Location(s):
o Location(s):
o Location(s):
:s Type:
be added automatically):
Dispersed flow only
I acknowledge and agree by my signature below that I am responsible for the performance of the maintenance procedures listed for
each SCM above, and attached O&M tables. I agree to notify NCDEQ of any problems with the system or prior to any changes to
the system or responsible party.
Responsible Party:
Title & Organization:
Street address:
City, state, zip:
Phone number(s):
Email:
Kurt Smith
Registered Agent, CWCP Holdings, LLC
100 S., 10th Street
Lillington, NC 27546
(919) 601-1660
kurtsdollarbill@yahoo.com
Signature: ; Date:, ZJ-
1, M1 i, e, 0 a Notary Public for the State of �} G
County of H o aeLt do hereby certify that U r� s a),&k
personally appeared before me this day of JLgt tffl I�R ,K 2022 and
acknowledge the due execution of th O erations and Maintenance Ag ement .
Witness my hand and official seal, -
MARIANA C. N
Notary Public, Nort
Harnett Cou
My CFgMRiWion
Seal
STORM-EZ
Version 1.5
ATEO
Carolina
ty
:xpires
My commission expires 10 J'2-7— 121
O&M Agreement
9/7/2022
Page 1 of 1
Low Density Maintenance Requirements
Important maintenance procedures:
The drainage area to the vegetated conveyance or vegetated receiving area will be
carefully managed to reduce the sediment load to the vegetated conveyance or
After the initial fertilization to establish the grass in the vegetated conveyance or the
vegetated receiving area, fertilizer will not be applied to the vegetated receiving
The vegetated conveyance or vegetated receiving area will be inspected quarterly. Records of
operation and maintenance will be kept in a known set location and will be available upon request.
section activities shall be performed as follows. Any problems that are found shall be repaired immediately.
SCM element:
Potential problem:
How to remediate the problem:
Vegetation is too short
Maintain grassed vegetation such that the swale or
Vegetation
or too long.
vegetated area does not erode during the peak flow
from the 10-year storm
Remove the trash/debris.
Vegetated receiving
Areas of bare soil
egra e the soil if necessary to remove the gully, an
areas
and/or erosive gullies
then re -sod (or plant with other appropriate species)
have formed.
and water until established. Provide lime and a one-
time fertilizer application.
Clogging has
Clean out the outlet device. Dispose of the sediment
occurred.
off -site.
The outlet device (if
applicable)
The outlet device is
damaged
Repair or replace the outlet device.
Erosion or other signs
of damage have
Repair the damage and improve the flow dissipation
occurred at the outlet.
structure.
The receiving water
Discharges from the
site are causing
erosion or
Contact the local NCDEQ Regional Office.
sedimentation in the