HomeMy WebLinkAbout20220726 Ver 1_Pre-Filing Documents_20220414 (2)1yroff.24
t— 1
,� � � • � j �• �� � � lsMn CORi1t PORA7E LIMI75 � I
/TW: 326.00 -
` 1 I
� I
8 � \
1 \ 1 \
i
I
I
�
� I
�LLj
w DS
w
O
Lo
� I
I
CI K-3�
11
1 I/
Q /
m`LLJ
\
N _ C
I� W / FFE: 331.0(
i
C9 I�
t Lo ,
o zz
J 0 —
O O m
\ Om O
i
- oDr OG
OO W4
Z
m a
—�
� N Cl
m
_ \ I rn
� � M N¢
cRgONc9 .
i
i
I-
C_/
AT THE CONCLUSION OF THE PROJECT ALL
SCMS INSTALLED ON -SITE MUST BE CERTIFIED
BY A DESIGN PROFESSIONAL AND THE TOWN OF
GARNER ENGINEERING DEPARTMENT MUST
RECEIVE ALL AS -BUILT DRAWINGS PRIOR TO
RECEIVING THE CERTIFICATE OF OCCUPANCY.
CONTACT THE ENGINEERING DEPARTMENT
PRIOR TO CONVERSION OF ANY EROSION
CONTROL DEVICE TO A STORMWATER DEVICE
GENERAL NOTES:
1. BOUNDARY AND EXISTING TOPOGRAPHICAL INFORMATION WAS PROVIDED BY SGROI LAND SURVEYING,
PLLC ON JANUARY 13, 2021.
2. CONTRACTOR TO VERIFY ALL DIMENSIONS AND EXISTING FEATURES PRIOR TO CONSTRUCTION.
3. INVERTS FOR EXISTING UTILITIES SHALL BE VERIFIED BY THE CONTRACTOR PRIOR TO CONSTRUCTION.
4. MATERIALS AND WORKMANSHIP TO CONFORM WITH STANDARDS AND SPECIFICATIONS OF LOCAL
JURISDICTIONAL AUTHORITIES.
5. POWER, PHONE, CABLE AND GAS SERVICE INSTALLATIONS SHALL BE COORDINATED WITH LOCAL UTILITY
PROVIDERS
6. ALL WATER INSTALLATIONS AND MATERIALS SHALL BE IN ACCORDANCE WITH THE REQUIREMENTS OF
RALEIGH UTILITIES AND NCDENR.
7. FIRE HYDRANTS MUST BE IN PLACE AND FUNCTIONAL BEFORE COMBUSTIBLE CONSTRUCTION BEGINS ON
SITE.
RETAINING WALLS THAT ARE GREATER THAN 4 FEET IN
1EIGHT WILL REQUIRE A SEPARATE BUILDING PERMIT
GRADING LEGEND
EXISTING GRADE
EXISTING STORM SEWER
PROPOSED GRADE
PROPOSED SPOT GRADE
YARD INLET OR DROP INLET
CURB INLET
JUNCTION BOX
STORM SEWER
TREE PROTECTION FENCE
WETLANDS
2240
676
+ 2154.75
O
THERE SHALL BE NO SOIL DISTURBANCE OR
RECOMPACTION WITHIN AREAS DESIGNATED FOR THE
TREE PRESERVATION AND PROTECTION FENCING.
INCLUDING NO STOCKPILING OF CONSTRUCTION OR
OTHER MATERIAL, TRAFFIC, OR BORING SAMPLE
ALL SPOT GRADES SHOWN ON STORM
STRUCTURES ARE AT GRATE ELEVATION
ALL SPOT GRADES ARE LABELED AT
BOTTOM OF CURB AND OR ASPHALT
GRADE UNLESS OTHERWISE NOTED.
ANY UNDERGROUND STORM WATER SYSTEM
WILL REQUIRE AN ANNUAL THIRD PARTY
INSPECTION AND CERTIFICATION THAT IS
TO BE SUBMITTED TO THE TOWN OF
GARNER ENGINEERING DEPARTMENT
aA MUS T C,
L I T Y pRo
O�r.�OJ�O o TF0 '
Gam- �O
Jw z=
D m
BEFORE YOU DIG!
CONTACT ONE -CALL CENTER
1-800-632-4949
GRAPHIC SCALE
60 0 30 60 120
( IN FEET )
I inch = 60 ft.
240
0
�a Co
SITE
GARNER STA TION BL VD
VI CINI TY MAP
1 "-2000'
vvv
I
Nvl�
PRELIMINARY
MARCH 16, 2022
FOR REVIEW
ONLY
NOT FOR
CONSTRUCTION
Ld
F-
Q
0
z
z0
F
Oa
5�
U
(N
w
0
m
O
z
C-3.0
7
N
O
N
m
m
Z
m
O
D