Loading...
HomeMy WebLinkAboutNCC223524_Site Plan or Location Map_202210190 I 0 D- 0) 1-1 I O I U) a� L 0 0 0 a U / a� U 0 0 3 U O m I 0 I �m rL� Cp PAD=72LQ0 — / __-721- 1. APPROVAL OF THE PLAN IS NOT AN AUTHORIZATION TO GRADE ADJACENT PROPERTIES. WHEN FIELD 720� CONDITIONS WARRANT OFF -SITE GRADING, PERMISSION MUST BE OBTAINED FROM THE AFFECTED 71PAD= 10.30 \ \ CB-23 —719PROPERTY OWNERS. — — — — — — 2. ALL CONTOURS AND SPOT ELEVATIONS REFLECT FINISHED GRADES INCLUDING ASPHALT. REFER TO / I ( l SSMH/ / / PAVEMENT CROSS SECTION DATA TO ESTABLISH CORRECT SUBBASE OR AGGREGATE BASE COURSE OTCB-2 CB-22 I / J LI Og FEMA ( /� �; I .I / �I ( / V J J / FLOOD WAY/ � � � \ / \ � \ � (PAD=7�17.83 \ � r o0 / �Op �" r TREE SAVE AREA, TYP. AVA ,— J v� \ RCP X696.00 � � — _ _ � � � _ _ — / � \ Y \ SNOW OR FORMERL/ — _ JONA7HAN M. HILL / J / — � �. �. OB sBE/427 / IQ\\ I / \ — 6y Jl."i \ /FES-18 / — — — J PID 138967 _ GASTONIA TWP ZONING. RS-12 FEMA FLOOD FRINGE - 710 — O LINE 0.2% CHANCE 4�i. FEMA FLOOD LINE \ ..� ! 1Z CHANCE � _// FEMA J I �-- .I 10 / — / — l / _ _ —NOW OR FORMERLY / I � / / / i � / — JONA7HAN M. HILL r: � / / / / / / / / / / / / / / DB 17E11270 D8 1146/721- -J — / / PlD 138970 GASTONIA TWP ��. ( / / — — — / 72 / ZONING. • RS-12 0 — zz XI 125 ELEVATIONS TO BE COMPLETED UNDER THIS CONTRACT. 3. CONTRACTOR SHALL BLEND NEW EARTHWORK SMOOTHLY TO TRANSITION BACK TO EXISTING GRADE. 4. CONTRACTOR SHALL IMMEDIATELY REPORT TO OWNER OR ENGINEER ANY DISCREPANCIES FOUND BETWEEN ACTUAL FIELD CONDITIONS AND CONSTRUCTION DOCUMENTS AND SHALL WAIT FOR INSTRUCTION PRIOR TO PROCEEDING. 5. ALL EARTH FILL TO BE COMPACTED TO MINIMUM 95% OF STD. PROCTOR MAXIMUM DRY DENSITY. 6. TOP 12 OF SUBGRADE OF BUILDING PADS TO BE COMPACTED TO MINIMUM 100 /o OF STD. PROCTOR MAXIMUM DRY DENSITY. 7. ALL RCP CULVERTS TO BE MINIMUM CLASS III RCP WITH TONGUE AND GROOVE OR BELL AND SPIGOT WATERPROOF JOINTS. JOINT MATERIAL SHALL BE BUTYL RUBBER MASTIC PER FSS-SS-S-00210. 8. HDPE CULVERTS TO BE CORRUGATED, SMOOTH -WALLED IN ACCORDANCE WITH ASSHTO M294 TYPE S. 9. SUBGRADE OF ROADS TO BE PROOF ROLLED PRIOR TO STONE PLACEMENT. 10. ABC STONE TO BE COMPACTED TO 100% OF STD. PROCTOR. 11. BITUMINOUS PAVEMENT BASE COURSE TO BE COMPACTED TO A DENSITY OF 92%. BITUMINOUS PAVEMENT INTERMEDIATE COURSE SHALL BE COMPACTED TO A DENSITY OF 92%. BITUMINOUS SURFACE COURSE TO BE COMPACTED TO A DENSITY OF 92%. 12. ALL CONCRETE FOR SIDEWALKS AND CURBS SHALL HAVE A MINIMUM 28-DAY COMPRESSIVE STRENGTH OF 3600 PSI. THE CONCRETE MIX AND CONSTRUCTION SHALL BE IN ACCORDANCE WITH NCDOT STANDARD SPECIFICATIONS. 13. ALL CATCH BASINS, DROP INLETS, AND JUNCTION BOXES SHALL BE CONSTRUCTED PER CITY OF GASTONIA STANDARDS. 14. RETAINING WALL DESIGN TO BE PROVIDED BY CONTRACTOR'S WALL DESIGN ENGINEER. RETAINING WALL DRAWINGS TO BE PROVIDED TO ENGINEER FOR REVIEW AND APPROVAL. IL i � a GRAPHIC SCALE 1. CONTRACTOR IS FULLY RESPONSIBLE FOR CONTACTING 0 25' 50' 100' APPROPRIATE PARTIES AND ASSURING THAT EXISTING UTILITIES ARE LOCATED PRIOR TO BEGINNING CONSTRUCTION. 2. CONTRACTOR IS RESPONSIBLE FOR PLACING BARRICADES USING FLAG MEN, ETC., AS NECESSARY TO INSURE SAFETY. ( IN FEET) 3. ALL PAVEMENT CUTS, CONCRETE OR ASPHALT, ARE TO BE REPLACED ACCORDING TO STANDARDS OF THE NORTH CAROLINA DEPARTMENT OF TRANSPORTATION AND LOCAL MUNICIPALITIES. HORIZONTAL 1 inch = 50 ft. q. SHORING WILL BE ACCORDING TO OSHA TRENCHING STANDARDS PART 1926 SUBPART P, OR AS AMENDED. Q � V u CN N W � z Q w �Q �Z W J WW O 0 ti ry Co N � � W U) N It Q V V O U";j-CD � N o0 L.L O 1- 6 rn Z •, SEAL •;� 0 8418 ; • A .F Z ZO Z Ise N Lfi 0 co N U W Uz J � ry J -0 U l W0 C) Oza �> O �� 2� M O N U� I—Lu W co � U wQ z I-_ J w W � W z 0 w z LU a 0 } m 0 z PROJECT#:2021-079 DATE:12/20/2021 DRAWN BY: JB CHECKED BY: JB TITLE GRADING PLAN SHEET NO. C-4.0