Loading...
HomeMy WebLinkAbout20220413 Ver 1_Copper District - Culvert Profile Export 1.pdf_20220623aim 0 U 0 Q a 0 c 0 _ I a 0 E Y O T 0 0 0 U) U ° U U 0 Q a O ° 0 _ I T 0 E Y T 0 Q U a � a w J O o .o_ m U 00 z Q ° Z c m � 3 J 0 0 o E / E U) U o N a -C (0 V) s= ., 0 a_ 0 U� U U a 0 o o Q E z a U U O f1 0 0 m Q) Q o a a L � � a o U) I ° U z U O 3 a 0 U .`u L U � a o a L � N m a a a o ° U o �I .0 � w O ° a o >0 w '� r� � J o _� Q� [Y a / c 0 N E Q U 00 L � o o ° Q N E N L O m N o ° U) U L C a . cD -° L6 U U) o a CN J U z w a � a J O U a V) 0 � U N 0 U ° U U) C U)' Q � U U' Uo -Y U a � E m D U U o U a o d ~ / PUBLIC STORMWATER / MAINTENANCE AND ACCESS EASEMENT 40 l IN w / / UA i rn / / / / / \ 0 W` FH Q; STA: 19+61.90 P P� TOWN OF CLAYTON PUBLIC UTILITY EASEMENT 3p3' / O / 0 CP C ON, /Tq NOTES: 1. ALIGNMENTS SHOWN AS UTILITY CENTERLINE ALIGNMENTS. REFER TO ROADWAY PLANS FOR ROAD CENTERLINE ALIGNMENT AND PROFILES. 2. REFER TO ROADWAY PLANS FOR STORM DRAINAGE STRUCTURE AND PIPE DESIGN INFORMATION. ALL STORM PIPES SHOWN FOR REFERENCE ONLY. I GRAPHIC SCALE IN FEET 0 20 40 80 I I I TAP STA: 29+11.01 u SSMH-28 - STA: 14+03.95 r RIM: 314.87 INV OUT: 308.00 (SSMH-26) III I VALVE �k /-STA: 29+18.79 —PLUG STA: 29+21.25 \I , �RJ PIPE STUB FOR FUTURE EXTENSION VALVE STA: 29+11.06 STA: 29+11.13 1 � 330 GRAPHIC SCALE IN FEET 0 20 40 80 328 HORIZONTAL EXISTING GROUND 326 n W000-aa�o rn 0) Of + + + + + 324 N = N-= NW U N N PROPOSED GROUND Q9-� W-Q — _ / >tn _U), CAI W >N _ 322 / \ LO / + N M / \ \ \ 0. N a� �cn °1 °� 0 +_:a N 0) 320 / a <a \ aN 318 / > fn n / a IN \ Q > H rn \ / �+ 316 a N CD � i + _Cn 4.00' MIN 314 N M o/ / + N 4.00' MIN 0 M (0 N 7(1Q 4- + / N 15" RCP 312 i Z� N) 4 N dQ Q U) m N O Q ~ N o + N ~ N 8" PVC WATER LINE 310 M 00)) N o + fn tO N a a 1 " RCP H N 16" DI WATER LINE 308 + N HN / \ I 306 N N N / — GO 304 >Cn IR50)0 M Q��4.00 ' MIN / a.< 04 -a o, $ ; 04 (0N 8" PVC 16"X8" TAPPING SLEEVE AND / \ H+ NN N-XQ �N `_Cn WATER LINE VALVE FOR 8" PVC WATER LINE TO RESIDENTIAL METERS 302 4.00' MIN \ \ X ' to N / 300 BEND WATERLINE UNDER STORM PIPE. _1 3.00' MIN / 8" PVC ENSURE WATER LINE 18" CLEARANCE 298 U_ 296 z Z 18" MIN. ILI 16" DI WATER LINE 6" P C \ 294 24" MIN. CLEARANCE 16"X8" TAPPING SLEEVE AND \ / \ VALVE FOR 8" PVC WATER LINE \ \ D TO RESIDENTIAL METERS 292 / 18" PVC to BEND WATERLINE UNDER SEWER PIPE. / 290 ENSURE 18" CLEARANCEno U.1 w " 7' N 288 w U) ' I Z J Li 286 284 i a) co r- Co CD �� N N O LO cD co O � O L zt P7 O� N 0) I'O 0O 0 �_ N N N 0j �_ Lri � N N N �`� �`� r7 r<j �`� M r7 L 20+00 21+00 22+00 23+00 24+00 25+00 26+00 27+00 28+00 29+00 2 Know what's below. Call before you dig. LIMITS OF DISTURBANCE: ±55.00 AC NOTE: ALL CONSTRUCTION TO BE IN ACCORDANCE WITH NCDEQ, NCDOT, AND TOWN OF CLAYTON STANDARDS AND SPECIFICATIONS APPLICABLE. IN THE EVENT OF A CONFLICT THE MORE STRINGENT STANDARD SHALL GOVERN. SURVEY NOTE: ALL EXISTING ON —SITE BOUNDARY AND TOPOGRAPHICAL INFORMATION WAS PROVIDED WITHIN A BOUNDARY SURVEY AND MAP OF TOPOGRAPHY PREPARED BY BALLENTINE ASSOCIATES, P.A. 221 PROVIDENCE ROAD CHAPEL HILL, NORTH CAROLINA 27514 (LICENSE NUMBER L-4732) 919-929-0481 DATED 10/29/2020. RECEIVED BY KIMLEY-HORN ON 06/30/2021 UPDATED ON 08/10/2021. OFF -SITE TOPOGRAPHIC INFORMATION TAKEN FROM PUBLICLY AVAILABLE GIS DATA. Signature: Signature: Town of Clayton Approved for Construction Date: Director/Assistant Director of Engineering Date: Planning Director Town of Clayton Engineering must be contacted at a minimum 48 hours prior to the commencement of construction activities. The Town of Clayton will not be responsible for errors and/or omissions on these approved set of plans. N \ LtJ 00 ~ N 0 (n Z W 12 0 U � O w > v, w > z LtJ 0 0 w In z 0 a_ LLJ z O r- N U U L0 z Z O o N Uj = LLJ QJ CO Q O O 0 Uo Q � X 0 ol,,QoN Z�L�=0 5 0 o ZCnow O L� J U w N : w I- Y W O J Cn — � w � � J N w w O Z N 0 ■ LLJ 0 Q LL_ N U � _ N O Q J m w r� O = DO wN Cn Q I\ m � Q �_ 0 w m Q w = O N _1 CD � C) Q � Q w � o o C) W J LL 0 0. v! U_ w I..L LLJ Z � 0 w a- zo O Q Z w U 0— U Z Z Cw W 2i O w Q o � p J W �_ C) w O U z o SHEET NUMBER C5.6