Loading...
HomeMy WebLinkAboutSW3190703_Add Info_20211019ROY COOPER Governor ELIZABETH S. BISER Secretary BRIAN WRENN Director Chris Bridges, PE 1186 Stonecrest Boulevard Tega Clay, SC 29708 AND Classica Homes Attn: Bill Saint, President/CEO 2215 Ayrsley Town Boulevard, Suite G Charlotte, NC 28273 :►I NORTH CAROLINA Environmental Quality October 19, 2021 Toll Southeast LP Company, Inc. Attn: Dan Rossi, VP of Land Development 14529 Grand Palisades Parkway Charlotte, NC 28278 Subject: Request for Additional Information Stormwater Permit No. SW3190703 Hemby Place Subdivision Union County Dear Mr. Bridges, Mr. Saint, & Mr. Rossi: The Division of Energy, Mineral and Land Resources (DEMLR), received a Stormwater Management Permit Minor Modification Application for the subject project on September 20, 2021. A review of that information has determined that the application is not complete. The following information is needed to continue the stormwater review: 1. Please correct the following issues with the Application: a. Part A2-7 & Part D — Per our records, the current permit holder is Classica Homes. Please either have the permittee (Classica Homes) complete the minor modification or submit a transfer application (available at the following website: https:Hdeq.nc.gov/about/divisions/energy-mineral-and-land-- resources/stormwater/stormwater-prorg am/post-construction-2) North Carolina Department of Environmental Quality I Division of Energy, Mineral and Land Resources 512 North Salisbury Street 1 1612 Mail Service Center I Raleigh, North Carolina 27699-1612 NORTH CAROLINA _ oepm nt of EnvimnmwUl uwl ry 919.707.9200 NOTE: The letter sent to the Mooresville Regional Office by Classica Homes, dated July 20, 2021, asking to be removed from the permit, is not an acceptable method to accomplish this goal. The permit must be transferred to another suitable party via a permit transfer application. Please refer to Section III, General Conditions, of the December 20, 2019 permit and 15A NCAC 02H .1045 for more information. The updated permitting language that will be included with this approved modification will make this process more clear. NOTE: The rules for certain aspects of permit transferring were recently updated per Session Law 2021-158 (Senate Bill 389) (https://www.ncle�,.gov/Sessions/2021Bills/Senate/PDF/S389y4.pdf) and we have not yet updated our forms to account for this. b. Part B2 — Since the designer of the proposed SCM is changing and the design itself is changing, please provide two hard copies and one electronic copy of the updated versions of the Application Form (SWU-101), Supplement-EZ Form, and O&M Agreement Form (if applicable) indicating the proposed changes to the design/designer. It is noted that the Minor Modification Application only requires updated plan sheets, however, updated forms should also be provided so that the permit package can accurately reflect the proposed design (this is an older form, albeit the most up-to-date version, and does not account for minor modifications that involve a change to the SCM/design forms). c. Part B3 — The originally approved deed restriction documents indicate that the lots were allocated a total of 243,085 sf (5.58 ac) of BUA. If the proposed wet pond is only capturing 5.99 ac of BUA (and there is more than 0.41 ac of roadway proposed) either the wet pond drainage area information is incorrect, or there has been a reallocation/reduction in the BUA allocated to the individual lots. Please either provide the revised deed restrictions (in accordance with this part of the Application) or revise the wet pond drainage area information/calculations. NOTE: The originally approved permit indicates that the drainage area of the wet pond was designed to capture 7.87 ac of BUA whereas this design is only proposing to capture 5.99 ac (This information will be clarified once the revised forms and supplements are provided). 2. Please correct the provided stage -storage tables. A note above the main pond permanent pool storage volume stage -storage table indicates that this table does not include the forebay, however, the cross -sectional area at the permanent pool elevation in this table (20,502 sf) is equal to that of the cross -sectional area at the permanent pool elevation of the temporary storage volume above permanent pool stage -storage table (a note above this table indicates that the temporary storage volume table accounts for the storage volume above both the forebay and the main pool). Please revise as needed for correctness and consistency. 3. This project is located within the Sixmile Creek Watershed which is subject to the Goose Creek Watershed Rules (15A NCAC 02B .0600). The Goose Creek Watershed Rules define the design volume as the difference between the pre -development and post - development 1-year 24-hour storm event (not based on the 1.0" storm as is typical in other parts of the state) and there is an emphasis on implementing stormwater control measures that promote infiltration/groundwater recharge. The provided water quality volume calculations do not appear to take this fact into consideration. Please revise the design volume/calculations/design to take the Goose Creek Rules into consideration (It appears as though the "over designed" design volume from the original permit was done intentionally in order to meet the Goose Creek Rules). NOTE: If this revision to the design causes an increase in the overall size of the SCM, it will no longer qualify as a minor modification and will need to be resubmitted as a major modification. 4. Provide pdfs of all revisions, 2 hardcopies of revised plan sheets, 1 hardcopy of other documents, and a response to comments letter briefly describing how the comments have been addressed. a. Pdfs must be uploaded using the form at: https:.//edocs.deq.nc.gov/Forms/SW-Supplemental-Upload b. Hard copies must be mailed or delivered to the following address: i. For FedEx/UPS: Jim Farkas 512 N. Salisbury Street, Office 640E Raleigh, NC 27604 ii. For LISPS: Jim Farkas 1612 Mail Service Center Raleigh, NC 27699-1612 Please note that this request for additional information is in response to a preliminary review. The requested information should be received by this Office prior to November 18, 2021, or the application will be returned as incomplete. The return of a project will necessitate resubmittal of all required items, including the application fee. Please reference the State assigned project number SW3190703 on all correspondence. If you need additional time to submit the information, please submit your request for a time extension to the Division at the contact below. The request must indicate the date by which you expect to submit the required information. The Division is allowed 90 days from the receipt of a completed application to issue the permit. The construction of any impervious surfaces, other than a construction entrance under an approved Sedimentation Erosion Control Plan, is a violation of NCGS 143-215.1 and is subject to enforcement action pursuant to NCGS 143-215.6A. If you have any questions concerning this matter please feel free to contact me at Jim.Farkas@ncdenr.gov or (919) 707-3646. Sincerely, )64)M4� Jim Farkas Environmental Engineer Stormwater Program cc: Mooresville Regional Office