Loading...
HomeMy WebLinkAboutSW1220701_Plansheet - SCM Detail_20220805 (2)BIORETENTION CELL MAINTENANCE: • WATERING: PLANTS SHOULD BE SELECTED TO BE TOLERANT OF THE BIORETENTION FACILITY'S PARTICULAR CONDITIONS. WATERING MAY BE REQUIRED TO INITIALLY ESTABLISH THE VEGETATION. WATERING SHOULD NOT BE REQUIRED AFTER ESTABLISHMENT (ABOUT 2 TO 3 YEARS). HOWEVER, WATERING MAY BE REQUIRED DURING PROLONGED DRY PERIODS AFTER PLANTS ARE ESTABLISHED. • EROSION CONTROL: INSPECT FLOW ENTRANCES, PONDING AREA, AND SURFACE OVERFLOW AREAS PERIODICALLY. REPLACE SOIL, PLANT MATERIAL, AND/OR MULCH IN AREAS WHERE EROSION HAS OCCURRED. EROSION PROBLEMS SHOULD NOT OCCUR WITH PROPER DESIGN EXCEPT DURING EXTREME WEATHER EVENTS. IF EROSION PROBLEMS DO OCCUR, THE FOLLWING ISSUES SHOULD BE REASSESSED: FLOW VOLUMES FROM THE CONTRIBUTING DRAINAGE AREA AND BIORETENTION SIZE; FLOW VELOCITIES AND GRADIENTS WITHIN THE BIORETENTION FACILITY FLOW DISSIPATION AND EROSION PROTECTION METHODS IN THE PRETREATMENT AND IN -FLOW AREAS IF SEDIMENT IS DEPOSITED IN THE BIORETENTION FACILITY, IMMEDIATELY DETERMINE THE SOURCE, REMOVE EXCESS DEPOSITS, AND CORRECT THE PROBLEM. • PLANT MATERIAL: DEPENDING ON PLANTS SELECTED AND AESTHETIC REQUIREMENTS, OCCASIONAL PRUNING AND REMOVAL OF DEAD PLANT MATERIAL MAY BE NECESSARY. BE CAREFUL TO PRUNE TREES AND SHRUBS TO MAINTAIN LINES OF SIGHT IN PARKING LOTS AND ALONG ROADWAYS. NCDOT STATES: "SHRUBS MUST BE KEPT LOW, AND TREES AND LARGE SHRUBS UNDER -TRIMMED SUFFICIENTLY TO PERMIT CLEAR SIGHT IN THE AREA BETWEEN 2 FEET AND 6 FEET ABOVE ROADWAY ELEVATIONS. REPLACE ALL DEAD PLANTS. HOWEVER, IF SPECIFIC PLANTS CONSISTENTLY HAVE A HIGH MORTALITY RATE, ASSESS THE CAUSE AND REPLACE WITH APPROPRIATE SPECIES. PERIODIC WEEDING IS NECESSARY UNTIL GROUNDCOVER PLANTS ARE ESTABLISHED. WEEDING SHOULD BECOME LESS FREQUENT IF AN APPROPRIATE PLANT DENSITY HAS BEEN ESTABLISHED. • NUTRIENTS AND PESTICIDES: THE SOIL MEDIA AND PLANT MATERIAL SHOULD HAVE BEEN SELECTED FOR OPTIMUM FERTILITY, PLANT ESTABLISHMENT AND GROWTH WITHIN THE PARTICULAR CONDITIONS OF EACH BIORETENTION FACILITY. NUTRIENT AND PESTICIDE INPUTS SHOULD NOT BE REQUIRED AND WILL DEGRADE THE POLLUTANT PROCESSING CAPABILITY OF THE BIORETENTION FACILITY, AS WELL AS CONTRIBUTE TO ADDITIONAL POLLUTANT LOADING TO RECEIVING WATERS. BY DESIGN, BIORETENTION FACILITIES ARE TYPICALLY SPECIFIED IN WATERSHEDS WHERE PHOSPHOROUS AND NITROGEN LEVELS ARE OFTEN ELEVATED. THEREFORE, THESE SHOULD NOT BE LIMITING NUTRIENTS WITH REGARD TO PLANT HEALTH. IF IN QUESTION, HAVE THE SOIL ANALYZED FOR FERTILITY. ADDITION OF COMMERCIAL FERTILIZER OR COMPOST TO BIORETENTION WILL LIKELY RESULT IN NUTRIENT EXPORT FROM THE BED. • MULCH: REPLACE MULCH ANNUALLY IN BIORETENTION FACILITIES WHERE HEAVY METAL DEPOSITION IS LIKELY (E.G. DRAINAGE AREAS THAT INCLUDE COMMERCIAL/INDUSTRIAL USES, PARKING LOTS, OR ROADS). METAL 'HOT SPOTS' OCCUR WHERE WATER ENTERS THE BED. IN RESIDENTIAL OR OTHER SETTINGS WHERE METAL DEPOSITION IS NOT A CONCERN, REPLACE OR ADD MULCH AS NEEDED TO MAINTAIN A 2 TO 4-INCH DEPTH. • FILTERING CAPACITY: WHEN THE FILTERING CAPACITY DIMINISHES SUBSTANTIALLY (E.G., WHEN WATER PONDS ON TE SURFACE FOR MORE THAN 12 HOURS), THE TOP FEW INCHES OF MATERIAL SHOULD BE REMOVED AND REPLACED WITH FRESH MATERIAL. THE REMOVED SEDIMENTS SHOULD BE DISPOSED OF IN AN ACCEPTABLE MANNER (E.G., LANDFILL) OR LAND APPLICATION. IF THAT DOES NOT SOLVE THE PROBLEM, MORE EXTENSIVE REBUILDING IS REQUIRED. IF THE BED HAS FILTER FABRIC INSTALLED UNDER THE MEDIA AND ABOVE THE WASHED ROCK, THE FILTER FABRIC MAY BE CLOGGED WITH SEDIMENT. IF CLOGGED FILTER FABRIC IS PRESENT, THE BED WILL NEED TO BE REBUILT. 100 ato]Lk•]go] 60601t•Ie 2'-6" TRENCH WIDTH 4 (MIN.) BIORETENTION CELLS NOTES: AN UNDERDRAIN WITH INTERNAL WATER STORAGE (IWS) SHALL BE INSTALLED UNLESS IT IS DEMONSTRATED THAT THE IN -SITU SOIL INFILTRATION RATE IS TWO INCHES PER HOUR OR GREATER IMMEDIATELY PRIOR TO THE INITIAL PLACEMENT OF THE MEDIA. THE TOP OF THE INTERNAL WATER STORAGE ZONE SHALL BE SET AT A MINIMUM OF 18 INCHES BELOW THE PLANTING SURFACE. FOR BIORETENTION CELLS WITH VEGETATION OTHER THAN SOD, THE PLANTING PLAN SHALL BE DESIGNED TO ACHIEVE A MINIMUM OF 75 PERCENT PLANT COVERAGE AT FIVE YEARS AFTER PLANTING. THE MAXIMUM COVERAGE WITH TREE OR SHRUB CANOPY SHALL BE 50 PERCENT AT FIVE YEARS AFTER PLANTING. IF SOD IS USED, THEN IT SHALL BE A NON-CLUMPIN, DEEP-ROOTED SPECIES. FOR BIORETENTION CELLS WITH VEGETATION OTHER THAN SOD, TRIPLE SHREDDED HARDWOOD MULCH SHALL BE USED FOR THE PORTION OF THE CELL THAT WILL BE INUNDATED. MULCH SHALL BE UNIFORMLY PLACED TWO TO FOUR INCHES DEEP. A MINIMUM OF ONE CLEAN -OUT PIPE SHALL BE PROVIDED ON EACH UNDERDRAIN LINE. CLEAN OUT PIPES SHALL BE CAPPED. FLOW SHOULD ENTER THE BIORETENTION CELL VIA DISPERSE FLOW OR AN ENERGY DISSIPATER. PRETREATMENT SHOULD BE PROVIDED �4" OF TOPSOIL ROVIDE GEOTEXTILE 4BRIC AROUND STONE NOTE: PERFORATED PIPE SHALL CONFORM TO NCDOT SPECIFICATIONS UNDER DRAIN DETAIL 9/16"0 NOT TO SCALE MADE IN THE U.S.A. AVAILABLE MATERIALS: MILD STEEL (NO FINISH) -WGT: 269.9 lbs. MILD STEEL (GALVANIZED) -WGT: 269.9 lbs. STAINLESS STEEL - WGT: 269.9 Ibs. ALUMINUM - WGT: 91.1 lbs. CUSTOM SIZES AVAILABLE AVAILABLE UPON REQUEST WITH: ACCESS PORT ANTI -VORTEX PLATE 'TRASH RACKS Ecom LDR-48 101 IRONWOOD ROAD 48" ROUND TOP -MOUNT TRASH RACK MIDDLESBORO, KY 40965 PH:(606)248-5560 DWG. NO. O FAX (606) 248-6308 /� REV. JRHOE.COM A 118493 SHEET 1 / 1 OUTLET PROTECTION TYPICAL (SCOURSTOP) PIPE W/ FLARED -END SECTION 6" GRAVEL JACKET - NON -PERFORATED PVC UNDERDRAIN SYSTEM CLEAN -OUTS - TYP. SEE PLANS FOR LOCATION OVERFLOW STORM INLET (MAX POND DEPTH = ® SEE PLANS) —OUTLET PROTECTION TYPICAL (SCOURSTOP) O PLANTING MIX 00 TOP OF FABRIC ELEVATION = 1000.0 PERMEABLE FILTER FABRIC (WRAPPED AROUND 6" WASHED STONE) 4 INCH PERFORATED DRAIN (SEE PLANS FOR LAYOUT) MEDIA NOTES: MEDIA MIX THE MEDIA SHOULD BE COMPOSED OF A HOMOGENOUS MIX OF THE FOLLOWING: • 75-85% MEDIUM TO COARSE WASHED SAND • 8-15% FINES (SILT AND CLAY) • 5-15% ORGANIC MATTER (SUCH AS PINE BARK FINES) MINIMUM MEDIA DEPTH ALL CELLS WITH TREES AND SHRUBS: 36 INCHES CELLS WITHOUT TREES AND SHRUBS: WITH NO IWS: 24 INCHES WITH IWS: 30 INCHES MEDIA P-INDEX LESS THAN 30 INCHES NSW WATERS LESS THAN 50 ELSEWHERE MEDIA MAINTENANCE MAINTAIN MEDIA SUCH THAT INFILTRATION RATE IS AT LEAST 1 IN/HR ELEV: 1007.00 PROPOSED STORM WATER MANAGEMENT SIZE REQUIREMENTS ELEVATION AREA (S.F.) AREA (AC) 1003.00 3.612 0.08 1004.00 3,890 0.09 POND VOL 3,751 CF 0.09 AC -FT TRASH RACK RIM: 1004.00 INV: 999.00 POND SLOPES - TYP. JUNCTION BOX FLARED -END RIM: 1006.25 SECTION WITH OUTLET PROTECTION TOP OF DIKE ELEV: 1007.0 To- 2 INV: 1004.00 11 — — 1 18" MAX POND 2 —II _ l ' INLET ELEVATION: 1 I PIPES o 1004.00 =III_ - - ------- TOP OF MEDIA ELEV: 1003.00 MEDIA MIX TOP OF IWS ZONE ELEV: 1001.50 PROVIDE 1 BOTTOM OF MEDIA ELEV: 1000.00 CLEANOUT PER UNDERDRAIN _I 4"v 12" SDR 35 PVC _I —I _11 I —III I 1.00% SLOPE I —I - PERFORATED 4" SDR 35 PVC INV: 999.0 NO MECHANICAL COMPACTION DO NOT MECHANICALLY 4" PERFORATED PIPE- TYP. COMPACT THE MEDIA, WATER (SEE PLANS FOR LAYOUT) OR WALK ON IT AS IT IS PLACED BIO RETENTION POND (FINAL CONDITION) BIO RETENTION POND OUTLET STRUCTURE DETAIL why use the SCOURSTOP SYSTEM? ScourStop transition mats protect against erosion and scour at culvert outlets with a vegetated solution in areas traditionally protected with rock or other hard armor. ScourStop is part of a system that includes semi -rigid transition mats installed over sod or turf reinforcement mats. Each Tx Tx '/:" mat is made of high -density polyethylene and secured tightly to the ground with anchors. Circular Culvert Outlet Protection PIPE DIAMETER VELOCITY <_ 10 FT/SEC 10 < VELOCITY < 16 FT/SEC TRANSITION MATWxL QUANTITY OF MATS TRANSITION MAT WxL QUANTITY OF MATS 12" 4' x 4' 1 4' x 8' 2 24" 8' x 8' 4 8' x 12' 6 36" 8' x 12' 6 1 12' x 20' 15 48" 12' x 16' 12 12' x 24' 18 60" 12' x 20' 15 16' x 32' 32 72" 16' x 24' 24 20' x 36' 45 These are minimum recommendations. More ScourStop protection may be needed depending upon site and soil conditions, per project engineer. If velocity is greater than 16 fps, contact manufacturer for design assistance. ScourStop mats have been shown to at least double the effectiveness of turf reinforcement mats. ScourStop fully vegetated channel (2:1 slope): velocity = 31 fps, shear stress = 16 psf. NOT TO SCALE 1. ScourStop mats must be installed over a soil cover: sod, seeded turf reinforcement mat (TIl geotextile, or a combination thereof. 2. For steep slopes (> 10%) or higher velocities (> 10 fit/sec), sod is the recommended soil cover. 3. Follow manufacturer's ScourStop Installation Guidelines to ensure proper installation. 4. Install ScourStop mats at maximum 1-2' below Flowline of culvert or culvert apron. (No waterfall impacts onto ScourStop mats.) 5. Performance of protected area assumes stable downstream conditions. LENGTH OF PROTECTION TRANl MAT APRON LENGTH WIDTH OF PROTECTION* rA IOL D = CULVERT DLAMETER :ii:IL�l9.•:i�'IF�r.�Eii:IF_Ir.! �ia!I!'�C� ���:r�IN��'r�Ir�l rrir��er�rk` ;:;:;:•::•:;:;:;::•:•:;;••: �rr1err�rr�e�a ................•..,.;.,'.,.errer�rererrrrr23so rer�il .......... a°irrrr��!�,errrrrrrrre� r�,:,irrrrrl rrrrrr, :;:;:;:;::•;�;:�:�:�:��:�: ,.,....,•., .•...�, .,,,.•.• r �r���ri6rrrrrr°irrrrcr�r� ,r�.,��. rr r :•:'':�:•::•:•:�:�::�:�:��:�:,r�urrr rrrrrrr rrr�rrr, rc•,��r�_r9.�5ia•IF�r:SiiiFl e�5::i�re��!6.lie�r!�.r/ie_I, —A CULVERT OUTLET PROTECTION - PLAN VIEW MAX. 1 "-2" DROP FROM CULVERT FIL I CULVERT FLOWLINE ONTO SCOURSTOP MATS PROFILE VIEW 0•°0°0°0°00000°0°0°00• 0°0°0°0°•00000°0°0°00 oo°o0o°0o0°0000oo000 • °000000°00000°000° o°o0°o0o°°o°o°0o°°o 0°°0°°000°0°°0°°0°°0°000 DIRECTION 0�000°° o°°°o°o°ono0000000°°* OF FLOW .000000000000000o .000o00o000o0000o o°o°o°o°o°o°o°o °0000°00000000000 o°o°o°o°o°o°o°o o0o0a0o0o000000 ANCHOR PATTERN Abut transition mats to end of culvert or culvert apron. Adjacent mats abut together laterally and longitudinally Minimum 8 anchors per mat. Extm anchors as needed for loose or wet soils. Extra anchors as needed for uneven soil surface. -� Transition mat apron protects culvert outlet. `Width of protection: Bottom width of channel and up both side slopes to a depth at least half the culvert diameter. r Protect bare/disturbed downstream soils from erosion with appropriate soil cover. Use normal -depth calculator to compute for downstream protection. C REESSED �LOCK - WASHER T SITION MAT sr ANCHoa srRAa 131-ANCHOR ANCHOR ILLUSTRATION Install anchors per SCourStop Installation Guidelines. Minimum depth 24" in compacted, cohesive soil. Minimum depth 30" in loose, sandy, or wet soil. Extra anchors as needed to secure mat tightly over soil cover. HANESGEOCOMPONENTS" ALEADERintheGEOSYNTHETICand EROSION COtITROLindustries A `.. 1,w..W coMVANr Learn more about our products at: HanesGeo.com 1888.239.4539 02014 Leggett & Platt. ln.moated 116959_1114 theg, solutionto,ip,p scourst_op, OUTLET PROTECTION INV = 998.00 I»:7LI13��I�:iy13:7N7 4-INCH MIN. PERFORATED PIPE IN 6-INCH MIN. WASHED STONE N ww ocn>-0 =(=j<LUD_ < nZ F- F- U M O H- Z p 0 cn�0 vWOz2- 0 U) OF- � 0- 0 Q p Z_Q�OzwUwLNu p O Omw � LU Q Zz NVOLUOZDw — Co F- Lu 0� LU 0 0 J O tZ LU 0- Z Q ~ LU LU LU ~0z Lu d LU z O A9 ADEPTUS ARCHITECTURE, INC. 121 MANLY STREET GREENVILLE, SC 29601 864-242-2514 U d a) o c"J - �; (V L, O 0 CO Q v m ao X �LO 00 LU Lui o r_:� .� 00 Cn iv �• § L cc)a U CO 41 U (u O L CL Engineer JDM •a7 Ze•�v2 2 0 z O z C/3 L.ICJ J C Q UJ LU Q CQ z C J Q (D Z Of /O V J 41 4) 0) N — Drawn By CWJ Date APRIL 2022 Revisions A ISSUE FOR PERMIT REVIEW 05.25.22 B REVISED PLANS 07.20.22 Project Number 2273.001 OUTLET STRUCTURE TRASH RACK NOT TO SCALE SCOURSTOP NOT TO SCALE Sheet C600