WQ0005763_Regional Office Physical File Scan Up To 10/14/2022
TWSA Operation and Maintenance Plan For Residual Operations The residual operations at TWSA consist of the following main processes. (a) Aerobic Digestion When sludge is wasted from the sbrs it is routed to one of the two aerobic digestors. The upper digestor (digestor #1) has a capacity of 285,000 gals. The lower digestor (digestor #2) has a capacity of 345,000 gals. The operator can route sludge flow to the digestors from the waste sludge pumps in the sbrs by using the valves on the waste sludge line. The valves and associated sludge piping are shown on Sheet CS of the record drawings by McGill Assoc. dated 10/12/2012. (b) Sludge Pump The sludge pump for the belt press is a progressive cavity pump (type BN 52-6Ls/A1-C1-C6-F0-SA-X) manufactured by Seepex Inc and rated for a pump rate of 100 gpm. The pump is located in the basement of the sludge pump/reusewater pump building. The location of this building on the site is shown on Sheet C3 of the record drawings by McGill Assoc. dated 10/12/2012. The details of the piping are shown on Sheet M21 of the record drawings by McGill Assoc. dated 10/12/2012. All lubrication and operation and maintenance of this equipment should adhere to the schedules set by Seepex Inc. These procedures are documented in the operation and maintenance manual supplied to TWSA by Seepex and dated September 2010. (c) Belt Press The belt press is a 1.0 meter capacity (model #GRS-1 Series III ) as manufactured by Komline-Sanderson. The press is located in the bottom of the Lab/Dryer building. All lubrication and operation and maintenance of this equipment should adhere to the schedules set by Komline-Sanderson. These procedures are documented in the operation and maintenance manual supplied to TWSA by Komline- Sanderson. (d) Polymer System The polymer system is a DynaBLEND model # L4S-1200-3P-13-3(Disc) supplied by Fluid Dynamics. The pump is located in a corner of the dryer/press building adjacent to the belt press. All lubrication and operation and maintenance of this equipment should adhere to the schedules set by Fluid Dynamics. These procedures are documented in the operation and maintenance manual supplied to TWSA by Fluid Dynamics. (e) Sludge Conveyors Information on screw conveyors and components can be found in the Fenton Operation and Maintenance Manual. (f) Sludge Storage Hopper The sludge storage hopper is located between the belt press and the sludge dryer and is used for storing dewatered sludge in preparation for batching to the dryer. (g) Burner The thermal fluid heater is manufactured by Fulton and is located adjacent to the dryer in the dryer/press building. Complete technical specifications and operation and maintenance information can be found in Volume 4 of the owner manuals supplied by Fenton to TWSA. (h) Dryer The dryer is a Fenix 48/10 manufactured by Fenton Environmental Technologies and is located in the dryer/press building. Complete operation and maintenance information can be found in the four (4) volume set supplied to TWSA by Fenton Environmental Technologies. (i) Silo and Baghouse system The Silo and Baghouse were manufactured and supplied to Fenton Environmental by GMD Environmental Technologies of Fort Worth, Texas. Complete operation and maintenance information can be found in volume three (3) of the four (4) volume set supplied to TWSA by Fenton Environmental Technologies. Belt Press Operations • The belt press augers should be turned on and allowed to run. Controls for these augers are accessed through the Allen Bradley Panel View Plus 1000 touch screen dryer panel. • Turn control power on at the belt press panel. After a delay the alarm will sound. Hit reset', button to silence the alarm. Pull on the washwater pump, hydraulic pump and belt switch in that order. Confirm that all equipment is operating properly. • Turn polymer pump on at the Dyna Flow pump control panel. Speed of the pump will be 6 adjusted based upon observations made at the press. • Turn sludge pump on by pulling the sludge pump button on the belt filter control panel. Pump feed rate is adjusted at the SPACP 550 panel located on the concrete column adjacent to the belt press. When the polymer begins to form a good floc in the sludge, close valve on mixing tank and write flow reading down on flow meter. Polymer feed rate and sludge feed rate should be adjusted to contain all of the product in the pressure zone of the belt and to produce the driest cake possible and still "turn loose" from the belt at the scraper above the auger. • At the end of the shift or days run, reverse the start up procedure to shut down the press. The daily log sheet has spaces for recording the hours operated and gallons of sludge. dewatered. Care should be taken to properly fill out all information so operations can be properly tracked. • When it becomes necessary to change out a drum of polymer it_is important to note the change and the flow reading on the daily sheet. This info is used to calculate dewatering costs. Dryer Operation Dryer controls are all contained in the Allen Bradley Panel View Plus 1000 panel . Each day the dryer is operated a Dryer Operations Daily Record should be completed. Dryer operations should be conducted as follows: • Dryer should be set to auto on touch panel screen. Record start time. Burner will activate and start building temperature. When a pre -determined temperature is reached fill cycle will start. • Record fill cycle start time. • After the timed fill cycle is complete, dry cycle will start. Record dry cycle start time. • Dry cycle timer will be on zero at dry cycle start time. Record temperatures as outlined on Daily Record at 50 min intervals until end of dry cycle. (Approx. 200 mins) • At the end of the dry cycle, the discharge cycle will start. Discharge cycle will last approx. 10 min and a new fill cycle will start. • When the last batch of sludge to be dried for the day is in the dryer, set control mode to Automatic Cool Down. This will prevent another batch from being loaded to the dryer and at the end of the cycle the dryer will go into cool down mode in preparation of shutting down. Silo and Baghouse Operation The controls of the baghouse should be set to auto on the panel adjacent to the silo. When the dryer discharges a batch to the silo the baghouse blower will automatically come on and keep dust from being discharged to the atmosphere. Periodic cleaning of the dust bin on the baghouse is required, this is accomplished by placing the backhoe bucket under the chute and opening the slide gate to allow dust to slide into the bucket. Some tapping on the side of the hopper with a rubber mallet may be required to loosen the accumulated dust. Sampling Procedures Daily sampling should be conducted in various points throughout the process to track and verify compliance with permitted values. • At least once per day a sample of the raw sludge feed to the belt press should be taken. This sample should be a composite of several samples taken at different times during the day. This sample should be obtained from the sample port at the intake to the raw sludge pump in the basement of the reuse water/sludge pump building. This sample should be kept in a container with an air tight lid until analyzed to prevent evaporation. At least once per day a sample of the dewatered sludge cake should be taken from the belt filter press. This sample should be a composite of several samples taken at different times during the day. This sample should be kept in a container with an air tight lid until analyzed to prevent evaporation. • Each batch of sludge discharged from the dryer should be sampled. This sample can be obtained after the discharge of each batch from the sampling port on the side of the discharge auger. This sample is hot when first obtained from the auger and should be allowed to cool before being bagged. • All of the above samples should be weighed and dried overnight in order to obtain total % solids values. Operators will be provided training in the proper procedures for sampling, storage and analysis of samples before they are expected to conduct analysis. Truck Loading Operations Trucks to be loaded with bioresidual should pull through under the silo. Drivers will be responsible for positioning of their trucks and plant operators will be responsible for loading operations. The storage silo control panel is located at the top of the stairs on the silo. This should be switched to the on position to enable the dust collector blower and chute controls to work. The valve on the green air piping theThe operator should lower the end of the chute to the bed of the truck and then switch on the rotary valve dispenser. The shorter distance residuals have to fall from the end of the chute to the bed of the truck dramatically lessens the amount of dust escaping during the loading process. Paperwork All users of the bioresiduals must sign and date a Utilization Agreement before taking or possessing the product. This agreement between TWSA and the end user must be signed and dated within one year by both parties. The hauler or transporter should be given a copy of the signed shipping manifest. The manifest should include an estimated tonnage and should list contact info for the generator and the user along with contact info on the trucking company with places for the generator, hauler and end user to sign. Info as to the proper procedures and safeguards should an accident or spill occur should be included on the manifest. Utilization Agreement f a. By signature and agreeing to accept the bulk class A residuals it is recognized that the application of Class A residuals is allowed under the conditions of this agreement. The application of these Class A residuals is considered the beneficial reuse of a waste under 15A NCAC 02T.1100. The application of these Class A Residuals to the land has been deemed permitted under 15A NCAC.1103(4) provided the conditions of this agreement are met. Any action resulting in the damages to surface waters or groundwater caused by failure to follow the conditions of the agreement is subject to enforcement action by the NC Division of Water Quality. b. The person or entity accepting the Class A residuals shall to the best of their knowledge meet the following application requirements: i. Application of the bulk residuals will stop if it becomes known that the application adversely affects a threatened or endangered species listed under section 4 of the Endangered Species Act or its designated critical habitat. ii. Application of the bulk residuals shall not occur when the land is flooded, frozen, or snow-covered or is otherwise in a condition such that runoff of the residuals would occur. iii. Application of the bulk residuals within the 100 tear flood elevation unless the bulk residuals are injected or incorporated within a 24-hour period following the residuals land application event. Flood elevation information is available at http://www.ncfloodmgps.com/default swf.asp; iv. Application of the bulk residuals shall not occur during a measurable precipitation event (i.e. > .01" per hour) or within 24 hours following a rainfall event of 0.5 inches or greater in a 24 hour period; V. Residuals stockpiled for more than 14 days shall be covered. vi. Application of bulk residuals shall not occur if the vertical separation of the seasonal high water table and the bulk residuals application is less than one foot. vii. Application of bulk residuals shall not occur if the vertical separation of the depth to bedrock and the depth of residuals application is less than one foot. viii. Application of bulk residuals shall not occur within 100 feet of a public or private water supply source; ix. Application of bulk residuals shall not occur within 100 feet of any well with the exception of monitoring wells; x. Application of bulk residuals shall not occur within 25 feet of surface waters. xi. Application of bulk residuals shall not occur if the application causes prolonged nuisance conditions. xii. Application of bulk residuals shall not occur if the land fails to assimilate the bulk residuals or the application causes the contravention of surface water or groundwater standards. xiii. Application or bulk residuals shall not occur if the slope io land is greater than 10 percent when bulk residuals are surface applied and if the slope of the land is greater than 18 percent when the bulk residuals are injected or incorporated; xiiii. Application of bulk residuals shall not occur if the pH is not maintained in the soil, residuals, and lime mixture, greater than 6.0, on land application sites onto which residuals are applied. Residuals may be applied to these sites provided that a sufficient amount of lime is also applied to achieve a final pH of the soil mixture of at least 6.0, or if an agronomist provides information indicating that the pH of the soil, residuals, and lime mixture is suited for the specified crop type. xv. If the land does not have an established vegetative cover in accordance with the crop management plan outlined by the local Cooperative Extension Office, the Department of Agriculture and Consumer Services, the Natural Resource Conservation Service, or other agronomist unless the bulk residuals are incorporated within a 24-hour period following the residuals application event or injected. The generator of the bulk residuals shall provide information on the proper use of the residuals including information on the nutrient quantities within the residuals and recommended application rates. A copy of the label or information sheet attached to bags or other containers or residuals as specified in condition 111.9. will satisfy this condition. d. The applicator or party receiving bulk residuals from the permittee shall supply all third parties receiving bulk residuals with documentation specifying that application shall occur consistent with the agreement. lam' Instructions, including contact information for key personnel, for the applicator or party receiving bulk residuals in the event that requirements specified in the utilization agreement are not met. f. A copy of the utilization agreement shall be maintained at the land application sites when bulk residuals are being applied. g. An education program shall be developed and implemented to inform employees and individuals accepting the residuals of the proper use of residuals. Educational materials shall be provided to all individuals accepting the residuals. The educational material shall be made available to the Division upon request. h. A label shall be affixed should be affixed to the bag or other container in which residuals that are sold or given away for application to the land, and or an information sheet shall be provided to the person who receives the residuals sold or given away in other containers for application to the land. The label or information sheet shall contain the following information: • The name and address of the person who prepared the residuals that is sold or given away in a bag or other container for application to the land. • A statement that application of the residuals to the land is prohibited except in accordance with the instructions on the label or information sheet. • A statement which indentifies that this material shall be prevented from entering any public or private water supply source (including wells) and any stream , lake, or river. • A statement that the residuals shall be applied at agronomic rates and recommended rates for intended uses. Permit No. WQ0005763 Tuckaseigee Water and Sewer Authority TWSA WWTP #1 ENGINEERING CERTIFICATION ❑ Partial N Final Class A Residuals Distribution October 8, 2010 Jackson County In accordance with 15A NCAC 02T .0116, I, H a r y G. 13 u c k in er as a duly registered Professional Engineer in the State of North Carolina, having the Permittee's authorization to N periodically ❑ weekly ❑ fully observe the construction of the permitted facility, hereby state to the best of my abilities that due care and diligence was used in the observation of the construction, such that the facility was built within substantial compliance and intent of this permit, the Division approved plans and specifications, and other supporting documentation. ❑ Any variation to this permit, the Division approved plans and specifications, and other supporting documentation has been documented in the attached as -built drawings, and shall serve as the Permittee's minor modification request to amend the permit accordingly, Provide a brief narrative description of any variations: garry G. Su, knee- Professio aI Engineer's Name r Gill AS_"ncia4x- PA. Engineering Firm 55 8rcdd S-4ree_k _Mailing Address A v, AlC 'MYD 1 City State Zip �l_Fl) A 2<Si11 -f g 10-1 2 rOS7S V. �ur-kner&rnca; ji�nai..�•-s•coM Telephone E-mail NC PE Seal, Signature & Date THE COMPLETED ENGINEERING CERTIFICATION, INCLUDING ALL SUPPORTING INFORMATION AND MATE,RL ,LS, SHALL BE SENT TO THE FOLLOWING ADDRESS: NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES DIVISION OF WATER QUALITY AQUIFER PROTECTION SECTION LAND APPLICATION UNIT By U.S. Postal Service: 1636 MAIL SERVICE CENTER By Courier/Special Delivery: 2728 CAPITAL BOULEVARD RALEIGH, NORTH CAROLINA 27699-1636 RALEIGH, NORTH CAROLINA 27604 WQ0005763 Version 1.2 Shell Version 100804 Page 14 of 14 Compliance Inspection Report Permit: WQ0005763 Effective: 09/11/14 Expiration: 07/31/19 Owner: Tuckaseigee Water & Sewer Authority SOC: Effective: Expiration: Facility: Jackson County WWTP County: Jackson 1871 N River Rd Region: Asheville Sylva NC 28779 Contact Person: Dan Harbaugh Title: Executive Director Phone: 828-586-5189 Ext.203 Directions to Facility: Hwy 40 W to Hwy. 74 W to Dillsboro. Hwy. 23 South to River Road. Facility is located at 1871 N River Rd System Classifications: Primary ORC: Certification: Phone: Secondary ORC(s): On -Site Representative(s): Related Permits: NC0063321 Tuckaseigee Water & Sewer Authority - TWSA Plant #3 NC0087602 Tuckaseigee Water & Sewer Authority - Whittier WWTP NC0020214 Tuckaseigee Water & Sewer Authority - TWSA WWTP#2 NC0039578' Tuckaseigee Water &Sewer Authority -Jackson County WWTP Inspection Date: Entry Time: )b � O v Exit Time: Primary Inspector: Beverly Price r Phone: 828-296-4500 Secondary Inspector(s): Reason for Inspection: Routine Inspection Type: Compliance Evaluation Permit Inspection Type: Distribution of Residual Solids (503) Facility Status: ❑ Compliant ❑ Not Compliant Question Areas: Miscellaneous Questions Record Keeping Treatment Sampling Pathogen and Vector Attraction (See attachment summary) PI�� ., mA SpU� ptv �es -aSe sit+ DA�°� 1 Page: 1 WAIAl-A Permit: WQ0005763 Owner - Facility: Tuckaseigee Water & Sewer Authority Inspection Date: 07/04/1976 Inspection Type: Compliance Evaluation Reason for Visit: Routine Inspection Summary: CA SLI CIS Sylva W.W-rP 2 ii�� ��I IJ� , W� .2` SAn. t- DS i,T fb -h?� Mixi ���C�2v�� S%� -� Orro. lS ���� � FOWL' c�-i es•�er' Q� �nlXad 1d LI/ P 'bry-tv- ALI, Vvi j-", scowo.43- Co , % a C,6 /vt 1 00 & A.,,) Page: 2 Permit: WQ0005763 Inspection Date: 07/04/1976 Owner - Facility: Tuckaseigee Water & Sewer Authority Inspection Type: Compliance Evaluation Reason for Visit: Routine Record Keeping Is GW monitoring being conducted, if required? Are GW samples from all MWs sampled for all required parameters? Are there any GW quality violations? Is GW-59A certification form completed for facility? Is a copy of current permit on -site? Are current metals and nutrient analysis available? Are nutrient and metal loading calculating most limiting parameters? a. TCLP analysis? b. SSFA (Standard Soil Fertility Analysis)? Are PAN balances being maintained? Are PAN balances within permit limits? Has land application equipment been calibrated? Are there pH records for alkaline stabilization? Are there pH records for the land application site? Are nutrient/crop removal practices in place? Do lab sheets support data reported on Residual Analysis Summary? Are hauling records available? Are hauling records maintained and up-to-date? # Has permittee been free of public complaints in last 12 months? Has application occurred during Seasonal Restriction window? Comment: Pathogen -and Vector Attraction a. Fecal coliform SM 9221 E (Class A or B) Class A, all test must be <1000 MPN/dry gram Geometric mean of 7 samples per monitoring period for class B<2.0*10E6 CFU/dry gram Fecal coliform SM 9222 D (Class B only) Geometric mean of 7 samples per monitoring period for class B<2.0*10E6 CFU/dry gram b. pH records for alkaline stabilization (Class A) c. pH records for alkaline stabilization (Class B) Temperature corrected d. Salmonella (Class A, all test must be < 3MPN/4 gram day) e. Time/Temp on: Digester (MCRT) Compost Yes No NA NE ❑ El. ❑❑ ❑ ❑ ❑ 11 ❑❑[A❑ ❑ ❑ jU ❑ ❑ ❑ 10"J" ❑ ❑ ❑ ❑ ❑ Page: 3 Permit; WQ0005763 Owner - Facility: Tuckaseigee Water & Sewer Authority Inspection Date: 07/04/1976 Inspection Type: Compliance Evaluation Class A lime stabilization f. Volatile Solids Calculations g. Bench -top Aerobic/Anaerobic digestion results Comment: Treatment Check all that apply Aerobic Digestion Anaerobic Digestion Alkaline Pasteurization (Class A) Alkaline Stabilization (Class B) Compost Drying Beds Other Comment:pirV- `�ok © t Sampling Describe sampling: Is sampling adequate? Is sampling representative? Comment: S l -D TONS P ' CA �-► ,tip /0 A S (a,-,AT.11 t t?. S`�- t it�tt" �f -b �� t UJ a� 2 e 7`- A R NOD 00P 4� br,y-el- 'If"'PIP5 Reason for Visit: Routine Yes No NA NE Yes No NA NE i-©OA Page: 4 Utilization Agreement These bioresiduals are produced by the Tuckaseigee Water and Sewer Authority under the authority of permit #WQ0005763 as issued by the NC Dept. of Environment and Natural Resources. Info regarding the beneficial reuse of this residual, including application rates, laboratory analysis and spill response procedures may be obtained at: Tuckaseigee Water and Sewer Authority Contact: Stan Bryson TWSA Plant #1 ph: 828-586-9318 1871 North River Rd. Sylva NC 28779 / a. By signature and agreeing to accept the bulk class A residuals it is recognized that the application of Class A residuals is allowed under the conditions of this agreement. The application of these Class A residuals is considered the beneficial reuse of a waste under 15A NCAC 02T.1100. The application of these Class A Residuals to the land has been deemed permitted under 15A NCAC.1103 (4) provided the conditions of this agreement are met. Any action resulting in the damages to surface waters or groundwater caused by failure to follow the conditions of the agreement is subject to enforcement action by the NC Division of Water Quality. Jb. The person or entity accepting the Class A residuals shall to the best of their knowledge meet the following application requirements: I i. Application of the bulk residuals will stop if it becomes known that the R� application adversely affects a threatened or endangered species listed under section 4 of the Endangered Species Act or its designated critical habitat. ii. Application of the bulk residuals shall not occur when the land is flooded, frozen, or snow-covered or is otherwise in a condition such that runoff of the residuals would occur. Jiii. Application of the bulk residuals within the 100 tear flood elevation unless the bulk residuals are injected or incorporated within a 24-hour period following the residuals land application event. Flood elevation information is available at littp://wNvw.ncfloodniaps.com/defauItcswf.asp; / iv. Application of the bulk residuals shall not occur during a measurable precipitation event (i.e. > .01" per hour) or within 24 hours following a rainfall event of 0.5 inches or greater in a 24 hour period; Ov Residuals stockpiled for more than 14 days shall be covered. Jvi. Application of bulk residuals shall not occur if the vertical separation of the � 36 O� Pop - seasonal high water table and the bulk residuals application is less than one (ak� "Pod ca` foot. 5e $ 60,f'/, Jvii. Application of bulk residuals shall not occur if the vertical separation of the depth e _JV7' 10, to bedrock and the depth of residuals application is less than one foot. viii. Application of bulk residuals shall not occur within 100 feet of a public or private water supply source; ix. Application of bulk residuals shall not occur within 100 feet of any well with the I exception of monitoring wells; I x. Application bulk 25 feet i of residuals shall not occur within of surface waters. Jxi. Application- of bulk residuals shall not occur if the application causes prolonged nuisance conditions. rJxii. Application of bulk residuals shall not occur if the land fails to assimilate the bulk residuals or the application causes the contravention of surface water or groundwater standards. Jxiii. Application of bulk residuals shall not occur if the slope for land is greater than 10 percent when bulk residuals are surface applied and if the slope of the land is greater than 18 percent when the bulk residuals are injected or incorporated; xiiii. Application of bulk residuals shall not occur if the pH is not maintained in the soil, residuals, and lime mixture, greater than 6.0, on land application sites onto which residuals are applied. Residuals may be applied to these sites provided that a sufficient amount of lime is also applied to achieve a final pH of the soil mixture of at least 6.0, or if an agronomist provides information indicating that the pH of the soil, residuals, and lime mixture is suited for the specified crop type. Jxv- If the land does not have an established vegetative cover in accordance with the crop management plan outlined by the local Cooperative Extension Office, the Department of Agriculture and Consumer Services, the Natural Resource Conservation Service, or other agronomist unless the bulk residuals are incorporated within a 24-hour period following the residuals application event or injected. 4dL : a f11 e2 t�� Viz-im v L coup rr i/c. The generator of the bulk residuals shall provide information on the proper use of the residuals including information on the nutrient quantities within the residuals and recommended application rates. A copy of the label or information sheet attached to bags or other containers or residuals as specified in condition ffl-.5" will satisfy this condition. J, ►2 , 2/ d. The applicator or party receiving bulk residuals from the permittee shall supply all third parties receiving bulk residuals with documentation specifying that application shall occur consistent with the agreement. i/. Instructions, including contact information for key personnel, for the applicator or party receiving bulk residuals in the event that requirements specified in the utilization agreement are not met. t� f. A copy of the utilization agreement shall be maintained at the land application sites when bulk residuals are being applied. ✓g. An education program shall be developed and implemented to inform employees and individuals accepting the residuals of the proper use of residuals. Educational materials shall be provided to all individuals accepting the residuals. The educational material shall be made available to the Division upon request. )h. A label shall be axed should be affixed to the bag or other container in which residuals that are sold or given away for application to the land, and or an information sheet shall be provided to the person who receives the residuals sold or given away in other containers.for application to the land. The label or information sheet shall contain the following information: • The name and address of the person who prepared the residuals that is sold or given away in a bag or other container for application to the land. V• A statement that application of the residuals to the land is prohibited except in accordance with the instructions on the label or information sheet. ✓• A statement which indentifies that this material shall be prevented from entering any public or private water supply source (including wells) and any stream, lake, or river. �• A statement that the residuals shall be applied at agronomic rates and recommended rates for intended uses. Signed: for Tuckaseigee Water and Sewer Authority Date Recipient Info: Name: Address: City, State ,Zip Signed: Date for ph: Recipient •alq!ssod 1! uol}!puoo leu121ao s}i o} eaae aql aaoIsaa 01 aq ll!M leoS alewilln aql •sanlle}uasa.Idai Aao}elnSaj @leis pue aaunno Alaadoid @qJ 10 uolloelsiles aql of pa}aldwoo aq ll!M do ueal:) •eaae ll!ds ay} of awll Aldde pue 'papaou 1! aadaanns gsniq /ueloi Aoldw3 n-ueal:) leUl3 (5) •Aou@Se A.IolelnSa.1 a1e1s @L1410 sanlle}uasa.Idai Aq panoidde eaae lesodsip a ol panowai pue pa4oalloa aq ll!M leiaa}ew pajeos-pues-pue-1ne1ls aql •lep@lew ouiuieww agl do oleos of ewe ll!ds agl ui paaa}}eos aq pinogs pues ao/pue nnealS -alq!ssod se leiaalew pall!ds agl10 gonw se anowa.l 01 a31Aaas juel oildas le3ol JO/pue salDlgaA uoileoildde a2pnls'luawdinba wnnaeA'saapeol pua-}uo.11 Aoldw3 n-ueal:) (ti) •01a 'saiaasinu ' saa}uao Alddns wiel'siawiel leaol •a•i 'uoilejado do-uealo aql alaldwoa of /uessaoau swa}! aaglo pue awll 'mells aql I@B of aaagnn lauuosiad do-uealo agl aslnpe ll!M al!s ll!ds aql uo @SJega ul uosiad aql ao aalaodsuea} aql •II!ds agl10 eaae luawuieluoo aleq meals aql juaw9ne o} paloni4suoa aq Aew sialaaeg LIN11e3 •sesodind gDns aol pasn aq llegs nneils 10 sailguenb lual)lllnS •.lalaaeq a wao3 II! s a4} u!e;u05 (£) -}!un liodsuejl paSewep ao aauieluoD ao aan}dni a se ganS II! s agl10 aaanos agj;leH (Z) •/uess03au se saoJ3ea}uo3 alenlid .Iaq}o ao 104 ON aq} woal pa;sanba.l aq Aew aouelslsse 'pwinbai si }uawdinba pue aogel leuoil!ppe 11 •alq!ssod se uoos se a}!s aq} o} painoi aq ueD 1oiluoo 0111eal pue saalAaas A:)U@SJawa os TT6 o} aq pinogs lies isig aql saaAoldwa ao :)ilgnd leaauaS agJ'sJslaoJow o} aasuep si aiagl }1 •sa1J!A1J:)e do-uealo alei}!ul pue @Sjeq:) a}eipawwi alel pinogs ia:podsue.11 aql s911!A113e n-ue513 II! s ;01uaWa eU%AJ (Z) l@Je!paww! uaNel aq llegs suoilae Nuimolloj aqlII! s e 10 Juana aqJ ul Ueld 8SUOCISOU II! S 0 TWSA 0045 NON -HAZARDOUS MANIFEST Generator Generator's Mailing Address: Generator's Site Address (If different than mailing): Emergency Contact in case of Accidental Spill Tuckaseigee Water and Sewer Auth. TWSA Plant # 1 Stan Bryson, WWTP Supt. 1246 West Main St. 1871 North River Rd. M-F 7:00am-5:00 pm ph: 828-508-1072 SYLVA, NC 28779 , SYLVA, NC 28779 After Hours-TWSA OnCall ph: 828-586-5189 ph: 828-586-9318 828-506-0681 Residuals Info These residuals are not Hazardous Waste as defined by 40CFR Part 261 or any applicable state law. Information and instructions in case of accidental spill are on the back of this document. Date: Estimated Load Size, tons: Transporter Transporter's Mailing Address Transporter's Driver Info Emergency Contact in case of Accident or Spill Name: Driver Name: name: Address: ph#: or name: City: Driver Phone #: State, Zip ph#: PH: Truck ID Destination Info -- Residuals to be Delivered To: Emergency Contact in case of Accident or Spill Physical Address: name: ph#: or City: Contact: name: State Zip PH: ph#: Generators Certificate I hereby certify that the above -described materials are not hazardous wastes as definedby 40 CFR Part 261 or any applicable state law, have been fully and accurately described, classified and packaged and are in proper condition for transportation according to applicable regulations. Tuckaseigee Water and Sewer Signature "On behalf of Month / Day / Yr Authority Transporter Acknowledge of Receipt of Materials - Printed Name Signature Month / Day / Yr Certificate of Receipt and Final Disposal/Application By signature and agreeing to accept the bulk class A residuals it is recognized that the application of Class A residuals is allowed under the conditions of the utilization agreement. The application of these Class A residuals is considered the beneficial reuse of a waste under 15A NCAC.1103(4) provided the conditions of this agreement are met. Any action resulting in the damages to surface waters or groundwater caused by failure to follow the conditions of the utilization agreement is subject to enforcement action by the NC Division of Water Quality Printed Name Signature Month / Day / Yr '#40 :Hd dlZ alels :aweu JO :;3e;uo� :#4d :ssajppv IealsA4d :aweU II!dS ao;uap!aay jo ase:) ui PEIUOD A:)UaBJaw3 :Ol paaaAllap aq o; slenppaa t% OR uoljeuljsaa '#4d OI pnil :Hd dIZ 'a;elS :aweU 10 :# auo4d JaAlJa :A;IJ '#4d o :aweN JanlIa asajppv :aweU :aweN ll!dS JO;Uap!:)Jv jo aseo UI 1:)e4uo0 AauaBJaw3 OJul JanlJa s,javodsuejl ssaippv SullleW s,Ja:wodsueJl aaliodsmi :suOI'az!S peol p9Iew1;s3 :ale(] 'Juawnaop s!4l jo joeq a4l Uo aJe ll!ds lejuap!a:)e jo asea ul suol;:)nJ;sul pue Uo!}ewJojul 'noel @leis alge3ildde Aue JO T9Z:Jed 2 jDot, Aq pau!fap se alseM snopJezeH IOU aJe slenp!saJ asa41 o ul s en rsa�l T 890-90S-8Z8 8T £6-98S-8Z8 : 4 d 68T S-98S-8Z8 :4d IIeJuo vSMl-sJnOH J@:4V 6LL8Z ON 'VAIAS 6LL8Z JN `b'AIAS ZL0T-80S-8Z8 :4d wd 00:S-we00:L d-!N 'pa Jana 41JON TLST u!eW IsaM 9tZT 'tdnS d1MM'uosAJg uejS T # Weld VSNU '4lny Jam@ S pue Jale/N aa8!aselonl ll!dS le}uap!xay}o ase:) ui ;ae;UO:) AJUaSJalU3 :($ulllew ue4;;uaja}}Ip;l) ssaippv ails s,Jo;ejaua9 :ssaJppv $ullleW s,Jo;eJauag Joje.iauaq 1S3JINVVY sn001JVZVH-NON 1 VSMl 0 Spill Response Plan In the event of a spill, the following actions shall be taken immediately. (1) Management of spill clean-up activities The transporter should take immediate charge and initiate clean-up activities. If there is danger to motorists, the general public or employees the first call should be to 911 so emergency services and traffic control can be routed to the site as soon as possible. If additional labor and equipment is required, assistance may be requested from the NC DOT or other private contractors as necessary. (2) Halt the source of the spill Such as a rupture or container or damaged transport unit. (3) Contain the spill Form a barrier. Sufficient quantities of straw shall be used for such purposes. Earthen barriers may be constructed to augment the straw bale containment area of the spill. The transporter or the person in charge on the spill site will advise the clean-up personnel where to get the straw, lime and other items necessary to complete the clean-up operation, i.e. local farmers, farm supply centers, nurseries, etc. (4) Clean-up Employ front-end loaders, vacuum equipment, sludge application vehicles and/or local septic tank service to remove as much of the spilled material as possible. Straw and/or sand should be scattered in the spill area to soak up the remaining material. The straw -and -sand -soaked material will be collected and removed to a disposal area approved by representatives of the state regulatory agency. (5) Final Clean-up Employ rotary brush sweeper if needed, and apply lime to the spill area. Clean up will be completed to the satisfaction of the property owner and state regulatory representatives. The ultimate goal will be to restore the area to its original condition if possible. (6) Notification As soon as possible after the spill occurs, the transporter will notify the TWSA Wastewater Operations Staff at (828-586-9318) or if after hours the TWSA ON -Call employee at (828-506-0681). The operator or on- call employee will notify the WWTP Superintendent. (7) Reportine The TWSA Superintendent or their designee will notify the Asheville Regional Office of the NCDENR by telephone (828-296-4500) as soon as possible, but not more than 24 hours after the occurrence. If after hours, weekends or holiday the State Emergency Operations phone number (828-858-0368) shall be used for notification. The transporter shall provide a written report within 48 hours of the spill to the TWSA WWTP Superintendent detailing the information and actions taken related to the spill. TWSA personnel will file a written report to the Asheville Regional office of the NCDENR within five days of the spill occurrence. V. 2018 Annual Residual Sampling Summary Form Permit Number. WQ 0005763 Facility Name: Tuckaseicee Water and Sewer Auth. NPDES # NC 0039578 W WTP Name: TWSA Plant # 1 Sample NC Certified Lab- Pace Analytical Date 2/15 Silo Comp. 3/8 (1:00 pm) Silo Comp. 3/8 (2:00 pm) Siio Com . 4/23 (12:46 pm) Silo Comp.- 5/8 (2:00 pm) Silo Comp. 7/25 (2:00 pm) Silo Como. 8f7 (2:00pm) Silo Comp. 9111 (1300) 'Silo Comp. 1011 (1300) Silo Comp. 11/6 (2:00) Silo Camp. Avg. Percent Solids 94.8 ✓ 94.8 ✓ 95.4 96.9 97.7 98.1 96.3 Aluminum 23,200 24,400 ; 21,100 32,700 25,350 P Arsenic ✓ 1.7 2.3 3.1 0.8 2.0 A Cadmium V 1.1 '� 1.1 1.3 t-'1.20 1.18 R Calcium 9.530 10,200 9110 10400 9,810 A Chromium 17.6 19.0 17.9 21.8 19.1 M Copper 283 315 312 r✓429 335 E Lead ✓l3.8 ✓ 13.7 15.3 ✓18.7 15.4 T Magnesium 4.550 k/ 4070 4580 3690 4.223 E Mercury 0.083 0.097 0.56 ✓ 1.1 0.460 R Molybdenum ✓ 8.3 6.0 -81 ✓5.8 7.1 S Nickel 13.6 V 15.2 13.8 17.3 15 h sm. 5.9 ✓ 5.8 6.3 5.8 Potassium .5600 5450 5560 3390 5,000 Selenium ✓4.1 ✓6.4 ✓ 3.9 ✓5.7 5.0 Sodium 839 802 992 508 785 Zinc 624 ✓ 679 A✓ 643 v-993 735 TKN 49 000 28,700 32,400 46.700 39,200 mg/ Ammonia -Nitrogen 2 260 v 1,270 1570 2260 1.840 kg Nitrate -Nitrite < 2.0 < 2.0 < 2.0 < 2.0 < 2.0 Plant Available N 15.200 8,860 10,000 14,500 12140 Total Phosphorous 13100 15700 9560 11400 12440 Corrosivi 5.9 5.8 6.3 5.8 I nitablli > 2 OO °F > 20O'F > 200, F > 200o F > 20Oo F SAR sodium adsorption ratio 1.8 1.7 2.1 ✓f.1 1.7 m /k Reactivity,cyanide < 1.1 < 1.0 < 1.0 < 1.0 < 1.0 m A Reactivity,sulfide < 10.5 < 10.3 < 10.2 < 10.2 < 10.3 mpnig. FecalColiform 1 1 <2' <2 <2 <2 <2 1 <2 1 <2• 1 <2 Ibs/ton Limit for HQ Residuals Ibs/ton, max monthly avg. 50.7 Aluminum 0.004 Arsenic 0.082 0.002 Cadmium 0.078 19.6 Calcium 0.038 Chromium 0.670 Copper 3.00 0.031 Lead 0.600 8.45 Magnesium 0.001 Mercury 0.340 0.014 Molybdenum 0.150 0.030 Nickel 0.840 ph, s.u. 10.0 Potassium 0.010 Selenium 0.200 1.57 Sodium 1.47 Zinc 5.60 78.4 TKN 3.7 Ammonia -Nitrogen Approx Fertilizer Value <2.0 Nitrate -Nitrite N P K 24.28 Plant Available N 1.2 1.2 0.5 24.88 Total Phosphorous I certify, under penalty of law, that this document was prepared under my direction or supervision in accordance with a system • Sample did not meet hold time. l designed to assure that qualified personnel properly gathered and evaluated the information submitted. I am aware that there are J significant penalties for submitting false information, including the possibility of fines and Imprisonment for knowing violations," ' Signature of Preparer TWSA Annual Residual Operation Totals 2018 SLUDGE FEED Polymer Usage Press Run Time Dryer Run Time I to Landfill or Farm avg Total I Total avg Ibs/ Total Total avg I Total avg Total Tipping Haulir DATE % Solids Gallons I Dry Ton 1000 gals $/month days Hrs $/month % Solids Days Loads Hrs $/month % Solids Ton Fee Fee Jan. No press run in Jan. No dryer run in Jan 0.0 $0 $0 Feb. 2.32 286,928 27.56 3.3 $1,575 1 7 77.1 $1,542 16.6 7 21 86.3 $ 1,726 95.7 0.0 $0 $0 Mar. 1.94 497,455 39.97 1.95 $1,700 11 127.0 $2,540 17.4 12 32 130.2 $ 2,358 95.6 0.0 $0 $0 • ... •0 � Apr. 1.9 450,546 1 35.82 1.92 1 490 11 119.8 $2.396 16.4 11 31 130.7 $ 2 614 94.2 28.0 56, Ma 1.75 357,087 26.14 2.35 $1,434 9 100.3 $2,006 16.6 9 24 97.8 $ 1,956 96.2 26.4 $925 $62( Jun. 1.82 273,171 21.00 2.66 $1,250 6 74.0 $1,480 18.4 6 17 69.8 $ 1,396 95.9 50.0 $0 $1,06 Jul. 1.92 316,689 25.35 2.11 $1,167 7 81.2 $1,624 17.6 7 19 80.2 $1,604 97.0 30.0 $0 $580 Aug. 2.13 179,728 15.95 2.5 $774 4 46.1 $922 18.2 4 12 50.9 $1,018 97.8 0.00 $0 $0 Sep. No prass run in Sept. No dryer run in Set 0.00 $0 $0 Oct. 2.49 265,305 27.16 3.54 $1,546 7 73.1 $1,462 19.1 9 24 101 $ 2,020 97.9 0.00 $0 $0 ov`7 2.64 166,034 18.15 3.08 $885 1 5 44.1 $882 18.8 5 15 61.7 $ 1,234 1 97.0 o, 24.30 $1.103 $50( Dec. 1 2.63 1153,8041 17.18 1 2.82 1 $745 1 4 1 43.6 1 $872 1 18.5 1 5 1 15 1 61.2 1 1,224 1 94.4 1 0.00 01 $0 Monthly 1 1 avg. 2.15 294,675 2`5.43 2.62 $1,257 7 78.6 $1,573 17.8 8 21 87.0 $ 1,715 96.2 13.2 169.0 278.3 ytd total 2,946,747 54.28 It 1 $12,666 1 71 1 786.3 1 $15,726 75 1 210 1 870 $17,150 15 .70 1 $2,028 $3,340 C. # of days press was run: 71 # of hours press was ran: 786.3 # of days dryer was run: 75�J v i` IDA Total # of hours dryer was ran: 869.8 Avg. # of hours Avg. # of hours press was run/day: 11.1 Estimated Annual wet ton of dewatered sludge produced: 1,431.8 dryer was run/day: 11.6 Est. dewatering and drying Estimated disposal cost/dry ton of sludge: 291 cost/dry ton of sludge: 34 Gas Purchased $ 28,602 Total annual cost Estimated annual tons Calculated total cost of of residual program: $79,312 of Class A Residual produced: 264.3 disposal /dry ton: 500 Water Resources ENVIRONMENTAL QUALITY IPATMCCRORY L 11I Governor DONALD R. VAN DER VAART Secretary S. JAY ZIMMERMAN Director October 4, 2016 Dan Harbaugh Tuckaseigee Water& Sewer Authority 1246 W. Main Street Sylva, NC 28779 SUBJECT: Annual Report (2015) Review Inspection TWSA Class A EQ Residuals Production Facility and Distribution Program Permit No: WQ0005763 Jackson County Dear Mr. Harbaugh: Enclosed please find a copy of the Annual Report Review Inspection Form from the inspection conducted on 9/20/2016. The facility was found to be in compliance with permit WQ0005763. - Please refer to the enclosed inspection report for additional observations and comments. If you or your staff have any questions, please call me at 828-296-4500. Sincerely, c Beverly Price Environmental Senior Specialist Enc. cc: Stan Bryson Wastewater Plant Operations Superintendent MSC 1617-Central Files -Basement _.Asheville_Files._ - G:\WR\WQUackson\Wastewater\Non-discharge\Tuckaseigee Water & Sewer Authority\CEI.2016.2015 AR Review.docx State of North Carolina I Environmental Quality I Water Resources 2090 U.S. Highway 70 Swannanoa, NC 28778 828 296 4500 Permit: WQ0005763 SOC: County: Jackson Region: Asheville Compliance Inspection Report Effective: 09/11/14 Expiration: 07/31/19 Owner: Tuckaseigee Water & Sewer Authority Effective: Expiration: Facility: TWSA Class A EQ Residuals Production Facility anc 1871 N River Rd Sylva NC 28779 Contact Person: Dan Harbaugh Title: Executive Director Phone: 828-586-5189 Ext.203 Directions to Facility: From the intersection of North River Road (SR 1359) and Hwy. 441 in Dillsboro, turn left onto SR 1359. Travel approximately 2 miles to TWSA Plant #1 on the left. System Classifications. Primary ORC: Certification: Phone: Secondary ORC(s): On -Site Representative(s): 24 hour contact name Stan D Bryson 828-586-5189 Related Permits: NC0063321 Tuckaseigee Water & Sewer Authority - TWSA Plant #3 NC0087602 Tuckaseigee Water & Sewer Authority - Whittier WWTP NC0020214 Tuckaseigee Water & Sewer Authority - TWSA WWTP#2 NC0039578 Tuckaseigee Water'& Sewer Authority - Jackson County WWTP Inspection Date: 09/20/2016 Entry Time: 03:30PM Exit Time: 05:OOPM Primary Inspector: Beverly Price( Phone: 828-296-4500 Secondary Inspector(s): Reason for Inspection: Routine Permit Inspection Type: Distribution of Residual Solids (503) Facility Status: Compliant ❑ Not Compliant Question Areas: Miscellaneous Questions Record Keeping (See attachment summary) Inspection Type: Annual Report Review 0 Pathogen and Vector Attraction Page: 1 Permit: WQ0005763 Owner - Facility: Tuckaseigee Water & Sewer Authority Inspection Date: 09/20/2016 Inspection Type: Annual Report Review Reason for Visit: Routine Inspection Summary: The inspection consisted of a review of the 2015 Annual Report. The review was conducted by Beverly Price of the Asheville Regional Office. All of the sludge (297.2 dry tons)that was generated at the Tuckaseigee Water and Sewer Authority facilities during 2015 was hauled by private contractor to: R&B Landfill.- operated by WasteManagement Inc. 610 Frank Bennett Road Homer Ga. 30080 Residuals were monitored for metals/nutrients/TCLP/Ignitability/Corrosivity/Reactivity -Analytical results appeared to be compliant with permit conditions. Pathogen Reduction verification via Fecal Coliform Density: requirements, were met. Pathogen/Vector Attraction Reduction verification via Alternative #5 - Heat Drying - Five dryer runs appeared to not meet the moisture reduction requirement. Page: 2 Permit: WQ0005763 Owner - Facility: Tuckaseigee Water i£ Sewer Authority Inspection Date: 09/20/2016 Inspection Type: Annual Report Review Reason for Visit: Routine. . Pathogen and Vector Attraction Yes No NA NE a. Fecal coliform SM 9221 E,(Class A or B) 0 ❑ ❑ ❑ Class A, all test must be <1000 MPN/dry gram Geometric mean of 7 samples per monitoring period for class B<2.0*10E6 CFU/dry gram ❑ Fecal coliform SM 9222 D (Class B only) ❑ ❑ ❑ Geometric mean of 7 samples per monitoring period for class B<2.0*10E6 CFU/dry gram ❑ b. pH records for alkaline stabilization (Class A) ❑ ❑ ❑ c. pH records for alkaline stabilization (Class B) ❑ 1:10 ❑ Temperature corrected ❑ d. Salmonella (Class A, all test must be < 3MPN/4 gram day) ❑ ❑ 0 ❑ e. Time/Temp on: ❑ ❑ E ❑ Digester (MCRT) ❑ Compost ❑ Class A lime stabilization ❑ I Volatile Solids Calculations ❑ ❑ 0 ❑ g. Bench -top Aerobic/Anaerobic digestion results ❑ ❑ 0 ❑ Comment: Record Keeping Yes No NA NE Is GW monitoring being conducted, if required? ❑ ❑ M ❑ Are GW samples from all MWs sampled for all required parameters? ❑ ❑ 0 ❑ Are there any GW quality violations? ❑ ❑ 0 ❑ Is GW-59A certification form completed for facility? ' ❑ ❑ 0 ❑ Is a'copy of current permit on -site? ❑ ❑ ❑ Are current metals and nutrient analysis available? ❑ ❑ ❑ Are nutrient and metal loading calculating most limiting parameters? 0. ❑ ❑ ❑ a. TCLP analysis? 0 ❑ ❑ ❑ b. SSFA (Standard Soil Fertility Analysis)? ❑ ❑ M ❑ Are PAN balances being maintained? ❑ ❑ 0 ❑ Are PAN balances within permit limits? ❑ ❑ E ❑ Has land application equipment been calibrated? ❑ ❑ M ❑ Are there pH records for alkaline stabilization? ❑ ❑ 0 ❑ Are there pH records for the land application site? ❑ ❑ 0 ❑ Are nutrienticrop removal practices in place? ❑ ❑ ❑ Page: 3 Permit: WQ0005763 Owner - Facility: Tuckaseigee Water & Sewer Authority Inspection Date: 09/20/2016 Inspection Type: Annual Report Review Reason for Visit: Routine Record Keeping Yes No NA NE Do lab sheets support data reported on Residual Analysis Summary? 0 ❑ ❑ ❑ Are hauling records available? ❑ ❑ ❑ Are hauling records maintained and up-to-date? ❑ ❑ ❑. # Has permittee been free of public complaints in last 12 months? ❑ ❑ ❑ Has application occurred during Seasonal Restriction window? ❑ ❑ 0 ❑ Comment: All residuals were hauled to R and B Landfill in Homer Ga. - haulina tickets are available uDon request. TVipe Yes No. NA NE Land Application ❑ Distribution and Marketing Page: 4 NCDENR 9 L North Carolina Department of Environment and Natural Resources Pat McCrory Donald R. van der Vaart Governor Secretary August 27, 2015 Dan Harbaugh . Executive Director Tuckaseigee Water & Sewer Authority 1246 W. Main Street Sylva, NC 28779 SUBJECT: Annual Report (2014)-Review Inspection TWSA Class A' EQ Residuals Production Facility and Distribution Program Permit No: WQ0005763 Jackson County . Dear Mr. Harbaugh: Enclosed please find a copy of the Annual Report Inspection Form from the inspection conducted on 8/12/2015. The facility was found to be in compliance with permit WQ0005763. Please refer to the enclosed inspection report for additional observations and comments. If you or your staff have any questions, please call me at 828-296-4685. Sincerely, Beverly Price Environmental Specialist Enc. cc: Stan Bryson, WWTP Operations Superintendent w/Enc. MSC 1617-Central Files -Basement ���� G:\WR\WQUackson\Wastewater\Non-discharge\Tuckaseigee Water & Sewer Authority\CEI15 2014 AR Review.doc Water Quality Regional Operations — Asheville Regional Office 2090 U.S. Highway 70, Swannanoa, North Carolina 28778 Phone: 828-296-4500 FAX: 828-299-7043 Internet: http://portal.nrdenr.orgMeb/wq An Equal Opportunity \ Affirmative Action Employer Permit: W00005763 SOC: County: Jackson Region: Asheville Compliance Inspection Report Effective: 09/11/14 Expiration: 07/31/19 Owner : ` Tuckaseigee Water & Sewer Authority Effective: Expiration: Facility: TWSA Class A EQ Residuals Production Facility anc 1871 N River Rd Sylva NC 28779 Contact Person: Dan Harbaugh Title:. Executive Director Phone: 828-586-5189 Ext.203 Directions to Facility: From the intersection of North River Road (SR 1359) and Hwy. 441 in Dillsboro, turn left onto SR 1359. Travel approximately 2 miles to TWSA Plant #1 on the left. System Classifications: Primary ORC: Certification: Phone: Secondary ORC(s): On -Site Representative(s): 24 hour contact name Stan D Bryson 828-586-5189 Related Permits: NCO063321 Tuckaseigee Water & Sewer Authority - Horsepasture River WWTP NCO087602 Tuckaseigee Water & Sewer Authority - Whittier WWTP NCO020214 Tuckaseigee Water & Sewer Authority - TWSA WWTP#2 NCO039578 Tuckaseigee Water & Sewer Authority - Jackson County WWTP Inspection Date: 08/12/2015 Entry Time: 09:OOAM Exit Time: 10:30AM Primary Inspector: Beverly Price Phone: 828-296-4500 Secondary Inspector(s): Reason for Inspection: Routine Permit Inspection Type: Distribution of Residual Solids (503) Facility Status: 0 Compliant ❑ Not'Compliant Question Areas: , Miscellaneous Questions Record Keeping (See attachment summary) Inspection Type: Annual Report Review Pathogen and Vector Attraction Page: 1 Permit: WQ0005763 Owner - Facility:_Tuckaseigee Water & Sewer Authority Inspection Date: 08/1212015 Inspection 'type: Annual Report Review Reason for Visit: Routine Inspection Summary: 67 Dry Tons of residuals were distributed during 2014. Metals/nutrients/TCLP analyses were conducted according to the permit requirements: Pathogen/Vector Attraction Reduction Requirements appeared to meet permit requirements. Fecal coliform results for 6/9/15 and 6/12/15 analyses were not compliant. These residuals were not distributed; they were landfilled. a Page: 2 Permit: W00005763 Owner- Facility:,Tuckaseigee Water & Sewer Authority Inspection Date: 08112/2015 Inspection Type :Annual Report Review, Reason•for Visit: Routine Type Land Application Distribution and Marketing Record Keeping Is GW monitoring being conducted, if required? Are GW samples from all MWs sampled'for all required parameters? Are there any GW quality violations? Is GW-59A certification form completed for facility? Is a copy of current permit on -site? Are current metals and nutrient analysis available? Are nutrient and metal loading calculating most limiting parameters? a. TCLP analysis? b. SSFA (Standard Soil Fertility Analysis)? Are PAN balances being maintained? Are PAN balances within permit limits? Has land application equipment been calibrated? Are there pH records for alkaline stabilization? Are there pH records for the land application site? Are nutdent/crop removal practices in place? Do lab sheets support data reported on Residual Analysis Summary? Are hauling records available? Are hauling records maintained and up-to-date? # Has permittee been free of public complaints in last 12 months? Has application occurred during Seasonal Restriction window? Comment: No seasonal restriction. Pathogen and Vector Attraction a.' Fecal coliform SM 9221 E (Class A or B) Class A, all test must be <1000 MPN/dry gram Geometric mean of 7 samples per monitoring period for class B<2.0*10E6 CFU/dry gram Fecal coliform SM 9222 D (Class B only) Geometric mean of 7 samples per monitoring period for class B<2.0*10E6 CFU/dry gram b. pH records for alkaline stabilization (Class A) c. pH records for alkaline stabilization (Class B) Temperature corrected d. Salmonella (Class A, all test must be < 3MPN/4 gram day) Yes No NA NE Yes No NA NE ❑ ❑ N ❑ ❑❑■❑ ❑❑❑■ ■❑❑❑ ❑❑■❑ ❑ ❑ ❑❑0M ❑ ❑ N ❑ ❑.❑ ❑ ❑❑■❑ ■❑❑❑ ❑❑❑■ ❑ ❑ ❑ Yes No NA NE ❑ ❑ ❑ ❑❑■❑ ❑ ❑ EEI E]EIs ❑ Page: 3 Permit; WQ0005763 Owner - Facility: Tuckaseigee Water & Sewer Authority Inspection Date: 08/12/2015 Inspection Type: Annual Report Review Reason for Visit: Routine e. Timefremp on: ❑ ❑ N ❑ Digester (MCRT) ❑ Compost ❑ Class A lime stabilization ❑ f. Volatile Solids Calculations ❑ ❑ N ❑ .g. Bench -top Aerobic/Anaerobic digestion results ❑ ❑ 0 ❑ Comment: June 9th and 12th. 2014 fecal coliform samples exceeded 1000 MPN. Those residuals were landfilled. Page: 4 r7 1, LEE State of Forth Carolina Department of )Environment and Natural Resources Division of Water Resources Water Quality Permitting Regional Staff Report August 1, 2014 To: DWR Water Quality Permitting Section Central Office Application No.: W00005763 Attn: Alice Wessner Regional Login No.: From: Beverly Price Asheville Regional Office I. GENERAL SITE VISIT INFORMIATION 1. Was a site visit conducted? ® Yes or ❑ No Annual Inspection & 2013 Annual Report Review a. Date of site visit: 6/19/14 b. Site visit conducted by: Beverly Price c. Inspection report attached? ® Yes or ❑ No d. Person contacted: and their contact information: Stan Bryson Wastewater Plant Operations Superintendent (828) 586-9318 e. Driving directions: From intersection of N. River Rd. (SR 1359) and Hwy 441 in Dillsboro, turn left onto SR 1359. Travel approximately 2 mi. to TWSA Plant #1 on the left. Il. PROPOSED FACILITIES FOR NEW AND MIODIFICATION APPLICATIONS 1. Facility Classification: (Please attach completed rating sheet to be attached to issued permit) 2. Are the new treatment facilities adequate for the type of waste and disposal system? ❑ Yes or ❑ No If no, explain: 3. Are site conditions (soils, depth to water table, etc) consistent with the submitted reports? ❑ Yes ❑ No ❑ N/A If no, please explain: 4. Do the plans and site map represent the actual site (property lines, wells, etc.)? ❑ Yes ❑ No ❑ N/A If no, please explain: 5. Is the proposed residuals management plan adequate? ❑ Yes ❑ No ❑ N/A If no, please explain: 6. Are the proposed application rates (e.g., hydraulic, nutrient) acceptable? ❑ Yes ❑ No ❑ N/A If no, please explain: 7. Are there any setback conflicts for proposed treatment, storage and disposal sites? ❑ Yes or ❑ No If yes, attach a map showing conflict areas. 8. Is the proposed or existing groundwater monitoring program adequate? ❑ Yes ❑ No ❑ N/A If no, explain and recommend any changes to the groundwater monitoring program: 9. For residuals, will seasonal or other restrictions be required? ❑ Yes ❑ No ❑ N/A If yes, attach list of sites with restrictions (Certification B) FORM: APSRSR 04-10 Page 1 of 3 1U. EXISTING FACILITIES FOR MODIFICATION AND RENEWAL APP ATIONS 1. Are there appropriately certified Operators in Charge (ORCs) for the facility? ❑ Yes ❑ No ® N/A ORC: Certificate #: Backup ORC: Certificate #: 2. Are the design, maintenance and operation of the treatment facilities adequate for the type of waste and disposal system? ® Yes or ❑ No If no, please explain: Are the site conditions (e.g., soils, topography, depth to water table, etc) maintained appropriately and adequately assimilating the waste? ❑ Yes or ❑ No N/A If no, please explain: 4. Has the site changed in any way that may affect the permit (e.g., drainage added, new wells inside the compliance boundary, new development, etc.)? ❑ Yes or ® No If yes, please explain: 5. Is the residuals management plan adequate? ® Yes or ❑ No If no, please explain: 6. Are the existing application rates (e.g., hydraulic, nutrient) still acceptable? ❑ Yes or ❑ No N/A If no, please explain: 7. Is the existing groundwater monitoring program adequate? ❑ Yes ❑ No ® N/A If no, explain and recommend any changes to the groundwater monitoring program: 8. Are there any setback conflicts for existing treatment, storage and disposal sites? ❑ Yes or ® No If yes, attach a map showing conflict areas. 9. Is the description of the facilities as written in the existing permit correct? ® Yes or ❑ No If no, please explain: 10. Were monitoring wells properly constructed and located? ❑ Yes ❑ No ® N/A If no, please explain: 11. Are the monitoring well coordinates correct in BIMS? ❑ Yes ❑ No ® N/A If no, please complete the following (expand table if necessary): Monitoring Well Latitude Longitude 0 , // 0 II 0 , If 0 , I, 0 , II 0 // 0 , it 0 , I/ 0 0 , 12. Has a review of all self -monitoring data been conducted (e.g., NDMR, NDAR, GW)? ® Yes or ❑ No Please summarize any findings resulting from this review: 13. Are there any permit changes needed in order to address ongoing BIMS violations? ❑ Yes or ® No If yes, please explain: 14. Check all that apply: ® No compliance issues ❑ Notice(s) of violation ❑ Current enforcement action(s) ❑ Currently under JOC ❑ Currently under SOC ❑ Currently under moratorium Please explain and attach any documents that may help clarify answer/comments (i.e., NOV, NOD, etc.) 15. Have all compliance dates/conditions in the existing permit been satisfied? ❑ Yes ❑ No ® N/A If no, please explain: 16. Are there any issues related to compliance/enforcement that should be resolved before issuing this permit? ❑ Yes ❑No®N/A If yes, please explain: FORM: APSRSR 04-10 Page 2 of 3 .. �,GIONAL OFFICE REG MENDATIONS 1. Do you foresee any problems with issuance/renewal of this permit? ❑ Yes or ® No If yes, please explain: 2. List any items that you would like APS Central Office to obtain through an additional information request: Item Reason Residuals Source Certification (#V. of the This information was not included in the application sent to ARO. application) 3. List specific permit conditions recommended to be removed from the permit when issued: Condition Reason 4. List specific special conditions or compliance schedules recommended to be included in the permit when issued: Condition Reason 5. Recommendation: ❑ Hold, pending receipt and review of additional information by regional office ® Hold, pending review of draft permit by regional office ❑ Issue upon receipt of needed additional information ❑ Issue ❑ Deny (Please state reasons: ) 6. Signature of report preparer: / Signature of APS regional supervisor: Date: C;"1.31 t`t V. ADDITIONAL REGIONAL STAFF REVIEW ITEMS FORM: APSRSR 04-10 Page 3 of 3 Compliance Inspection Repot Permit: WQ0005763 Effective: 10/08/10 Expiration: 07/31/14 Owner: Tuckaseigee Water & Sewer Authority SOC: Effective: Expiration: Facility: TWSA Class A EQ Residuals Production Facility anc County: Jackson 1871 N River Rd Region: Asheville Sylva NC 28779 Contact Person: Dan Harbaugh Title: Executive Director Phone: 828-586-5189 Ext.203 Directions to Facility: From the intersection of North River Road (SR 1359) and Hwy. 441 in Dillsboro, turn left onto SR 1359. Travel approximately 2 miles to TWSA Plant #1 on the left. System Classifications: Primary ORC: Certification: Phone: Secondary ORC(s): On -Site Representative(s): 24 hour contact name On -site representative Related Permits: Inspection Date: 06/19/2014 Primary Inspector: Beverly Price Secondary Inspector(s): Stan D Bryson Stan D Bryson Entry Time: 01:OOPM Exit Time: 01:45PM Reason for Inspection: Routine Permit Inspection Type: Distribution of Residual Solids (503) Facility Status: RM Compliant Not Compliant Question Areas: ® Miscellaneous Questions IN Record Keeping ® Sampling (See attachment summary) 828-586-9318 828-586-9318 Phone: 828-296-4500 Inspection Type: Compliance Evaluation U Treatment Page: 1 Permit: WQ0005763 Owner - Facility: Tuckaseigee Water & Sewer Authority Inspection bate: 06/19/2014 Inspection Type: Compliance Evaluation Reason for Visit: Routine Inspection Summary: This site visit included a tour of the facility Sludge from the other 3 facilites and WWTP#1 is mixed in the upper aerobic digester. The thickened sludge from the upper digester is sent to the lower digester and mixed/aerated further. From here the sludge goes to the belt -press and then to the dryer. The maintenance/operation logs were good. Dried sludge is stored in the silo. A Non -Hazardous Manifest is filled out each time the hauler comes to pick up residuals. A Spill Control Plan is located on the back of the manifest. Soil Plus, Inc. is currently taking the sludge. Kinsland Trucking out of Whittier, NC is hauling the product for Soil Plus (Scott Carpenter). In addition to the nutrient analysis performed by Tuckaseigee, Mr. Carpenter has the product analyzed for nutrient content by A&L Eastern Labs. Mr. Bryson indicated that he might need to send some product to the landfill to make room in the silo Page: 2 Permit: WQ0005763 Owner - Facility: Tuckaseigee Water & Sewer Authority Inspection Date: D6/19/2014 Inspection Type: Compliance Evaluation Reason for Visit: Routine Type Yes No NA NE Land Application ❑ Distribution and Marketing Record Keeping Yes No NA NE Is GW monitoring being conducted, if required? Are GW samples from all MWs sampled for all required parameters? El El ® ❑ Are there any GW quality violations? Is GW-59A certification form completed for facility? Is a copy of current permit on -site? 11 Are current metals and nutrient analysis available? Are nutrient and metal loading calculating most limiting parameters? a. TCLP analysis? b. SSFA (Standard Soil Fertility Analysis)? Are PAN balances being maintained? Are PAN balances within permit limits? Has land application equipment been calibrated? Are there pH records for alkaline stabilization? 1:1 El IN El Are there pH records for the land application site? El El N 0 Are nutrient/crop removal practices in place? Do lab sheets support data reported on Residual Analysis Summary? Are hauling records available? Are hauling records maintained and up-to-date? # Has permittee been free of public complaints in last 12 months? Has application occurred during Seasonal Restriction window? Comment: Treatment Yes No NA NE Check all that apply Aerobic Digestion Anaerobic Digestion Alkaline Pasteurization (Class A) Alkaline Stabilization (Class B) El Compost El Drying Beds El Other Comment: Hot oil dryer Page: 3 Permit: WQ0005763 Owner - Facility: Tuckaseigee Water & Sewer Authority Inspection Date: 06/19/2014 Inspection Type : Compliance Evaluation Reason for Visit: Routine Sampling Describe sampling: d Total percent solids samples are colleced at the hopper from each batch run from the dyer. Fecal coliform, metals, nutrients and TCLP samples are collected either from the hopper or from the storage silo. Is sampling adequate? Is sampling representative? Comment: Yes No NA NE x ❑ ❑ ❑ ®❑❑❑ Page: 4 Compliance Inspection Report Permit: WQ0005763 Effective: 10/08/10 Expiration: 07/31/14 owner: Tuckaseigee Water & Sewer Authority SOC: Effective: Expiration: Facility: TWSA Class A EQ Residuals Production Facility anc County: Jackson 1871 N River Rd Region: Asheville Sylva NC 28779 Contact Person: Dan Harbaugh Title: Executive Director Phone: 828-586-5189 Ext.203 Directions to Facility: From the intersection of North River Road (SR 1359) and Hwy. 441 in Dillsboro, turn left onto SR 1359. Travel approximately 2 miles to TWSA Plant #1 on the left. System Classifications: Primary ORC: Certification: Phone: Secondary ORC(s): On -Site Representative(s): 24 hour contact name Stan D Bryson 828-586-9318 On -site representative Stan D Bryson 828-586-9318 Related Permits: Inspection Date: 06/17/2014 Entry Time: 02:OOPM Exit Time: 03:OOPM Primary Inspector: Beverly Price Phone: 828-296-4500 Secondary Inspector(s): Reason for Inspection: Routine Inspection Type: Compliance Evaluation Permit Inspection Type: Distribution of Residual Solids (503) Facility Status: JX Compliant Not Compliant Question Areas: JE Miscellaneous Questions JU Pathogen and Vector Attraction (See aifachment summary) Page: 1 Permit: WQ0005763 Owner - Facility: Tuokaseigee Water & Sewer Authority Inspection Date: 06/17/2014 Inspection Type : Compliance Evaluation Reason for Visit: Routine Inspection Summary: The inspection included a review of the 2013 Annual Report. 123.25 Dry Tons of product was distributed during 2013. 64.8 tons of sludge were hauled to R and B Landfill in Homer Ga Metals/nutrient and TCLP analyses were completed as required. average concentration limits. in 2013. Metals were within ceiling concentration and monthly Pathogen and vector attraction reduction requirements appeared to be met based on the data submitted. 3rd Batch - 7/29/13 Calculations were not completed. Please make sure all calculations are completed. Recipient information was included. Please include the degree C or F on the dryer operations daily log. Page: 2 i Permit: W00005763 Owner - Facility: Tuckaseigee Water & Sewer Authority Inspection Date: 06/17/2014 Inspection Type : Compliance Evaluation Reason for Visit: Routine Type Land Application Distribution and Marketing Pathogen and Vector Attraction a. Fecal coliform SM 9221 E (Class A or B) Class A, all test must be <1000 MPN/dry gram Geometric mean of 7 samples per monitoring period for class B<2.0*10E6 CFU/dry gram Fecal coliform SM 9222 D (Class B only) Geometric mean of 7 samples per monitoring period for class B<2.0*10E6 CFU/dry gram b. pH records for alkaline stabilization (Class A) c. pH records for alkaline stabilization (Class B) Temperature corrected d. Salmonella (Class A, all test must be < 3MPN/4 gram day) e. Time/Temp on: Digester (MCRT) Compost Class A lime stabilization f. Volatile Solids Calculations g. Bench -top Aerobic/Anaerobic digestion results Comment: Yes No NA NE Yes No NA NE El ❑ ❑ ® ❑ ❑ ❑ 0 ❑ El ❑❑On ❑ ❑ 9 ❑ Page: 3 LTIPFA 40 w NCDENR �, i�C North Carolina Department of Environment and Natural Resources Pat McCrory John E. Skvarla, III Governor Secretary June 23, 2014 Dan Harbaugh, Executive Director Tuckaseigee Water & Sewer Authority 1246 W. Main Street Sylva, NC 28779 SUBJECT: Compliance Evaluation Inspections TWSA Class A EQ Residuals Production Facility and Distribution Program Permit No: WQ0005763 Jackson County Dear Mr. Harbaugh: Enclosed please find a copy of the Compliance Evaluation Inspection Forms from the inspections conducted on June 17 & 19, 2014. The facility was found to be in compliance with permit WQ0005763. Please refer to the enclosed inspection reports (Inspection Summary Page 2) for additional observations and comments. If you or your staff have any questions, please call me at (828) 296-4685. Sincerely, .�! R/L'� Beverly Price Environmental Specialist Enc cc: Stan Bryson, Wastewater Treatment Plant Superintendent w/Enc. Water Quality Central Files MSC 1617-Central Files -Basement Asheville Files G:\WR\WQUackson\Wastewater\Non-discharge\Tuckaseigee Water & Sewer Authority\WQ0005763 CEI14 & 2013 AR Review.doc Water Quality Regional Operations —Asheville Regional Office 2090 U.S. Highway 70, Swannanoa, North Carolina 28778 Phone: 828-2964500 FAX: 828-299-7043 Internet: http://portal.ncdenr.org/web/wgtws An Equal Opportunity 1 Affirmative Action Employer Compliance Inspection Report Permit: WQ0005763 Effective: 10/08/10 Expiration: 07/31/14 Owner: Tuckaseigee Water & Sewer Authority SOC: Effective: Expiration: Facility: TWSA Class A EQ Residuals Production Facility and Distribution Program County: Jackson 1871 N River Rd Region: Asheville Sylva NC 28779 Contact Person: Dan Harbaugh Title: Executive Director Phone: 828-586-5189 Ext.203 Directions to Facility: From the intersection of North River Road (SR 1359) and Hwy. 441 in Dillsboro, turn left onto SR 1359. Travel approximately 2 miles to TWSA Plant #1 on the left. System Classifications: Primary ORC: Certification: Phone: Secondary ORC(s): On -Site Representative(s): 24 hour contact name On -site representative Related Permits: Inspection Date: 06/19/2014 Primary Inspector: Beverly Price Secondary Inspector(s): Stan D Bryson Stan D Bryson Entry Time: 01:00 PM Reason for Inspection: Routine Permit Inspection Type: Distribution of Residual Solids (503) Facility Status: ■ Compliant ❑ Not Compliant Question Areas: 0 Miscellaneous Questions E Record Keeping (See attachment summary) Exit Time: 01:45 PM Phone: 828-586-9318 Phone: 828-586-9318 Phone: 828-296-4500 Inspection Type: Compliance Evaluation E Treatment N Sampling Page: 1 Permit: WO0005763 Owner - Facility: Tuckaseigee Water & Sewer Authority Inspection Date: 06/19/2014 Inspection Type: Compliance Evaluation Reason for Visit: Routine Inspection Summary: This site visit included a tour of the facility. Sludge from the other 3 facilites and WWTP#1 is mixed in the upper aerobic digester. The thickened sludge from the upper digester is sent to the lower digester and mixed/aerated further. From here the sludge goes to the belt -press and then to the dryer. The maintenance/operation logs were good. Dried sludge is stored in the silo. A Non -Hazardous Manifest is filled out each time the hauler comes to pick up residuals. A Spill Control Plan is located on the back of the manifest. Soil Plus, Inc. is currently taking the sludge. Kinsland Trucking out of Whittier, NC is hauling the product for Soil Plus (Scott Carpenter). In addition to the nutrient analysis performed by Tuckaseigee, Mr. Carpenter has the product analyzed for nutrient content by A&L Eastern Labs. Mr. Bryson indicated that he might need to send some product to the landfill to make room in the silo. Page: 2 Permit: WQ0005763 Owner - Facility: Tuckaseigee Water & Sewer Authority Inspection Date: 06/19/2014 Inspection Type: Compliance Evaluation Reason for Visit: Routine Type Yes No NA NE Land Application n Distribution and Marketing ■ Record Keeping Yes No NA NE Is GW monitoring being conducted, if required? ❑ n ■ n Are GW samples from all MWs sampled for all required parameters? n n ■ Are there any GW quality violations? n n ■ ❑ Is GW-59A certification form completed for facility? n n ■ n Is a copy of current permit on -site? ■ In n n Are current metals and nutrient analysis available? n n ■ Are nutrient and metal loading calculating most limiting parameters? n n ■ n a. TCLP analysis? nn■n - b. SSFA (Standard Soil Fertility Analysis)? ❑ n ■ n Are PAN balances being maintained? ❑ ❑ ■ n Are PAN balances within permit limits? n fl ■ n Has land application equipment been calibrated? n n ■ Are there pH records for alkaline stabilization? n n ■ n Are there pH records for the land application site? n n ■ n Are nutrienticrop removal practices in place? n n ■ Do lab sheets support data reported on Residual Analysis Summary? n n ■ n Are hauling records available? n n ■ Are hauling records maintained and up-to-date? n n ■ n # Has permittee been free of public complaints in last 12 months? n n ■ n Has application occurred during Seasonal Restriction window? n n ■ Comment: T-6.,,. 4 Yes No NA NE Check all that apply Aerobic Digestion ■ Anaerobic Digestion n Alkaline Pasteurization (Class A) In Page: 3 Permit: WQ0005763 Owner - Facility: Tuckaseigee Water & Sewer Authority Inspection Date: 06/19/2014 Inspection Type: Compliance Evaluation Reason for Visit: Routine Alkaline Stabilization (Class B) Compost ❑ Drying Beds ❑ 1 Other ■ Comment: Hot oil dryer Sampling Yes No NA NE Describe sampling: Total percent solids samples are colleced at the hopper from each batch run from the dyer. Fecal coliform, metals, nutrients and TCLP samples are collected either from the hopper or from the storage silo. Is sampling adequate? Is sampling representative? Comment: ■nnn ■nnn Page: 4 Compliance Inspection Report Permit: WO0005763 Effective: 10/08/10 Expiration: 07/31/14 Owner: Tuckaseigee Water & Sewer Authority SOC: Effective: Expiration: Facility: TWSA Class A EQ Residuals Production Facility and Distribution Program County: Jackson 1871 N River Rd Region: Asheville Sylva NC 28779 Contact Person: Dan Harbaugh Title: Executive Director Phone: 828-586-5189 Ext.203 Directions to Facility: From the intersection of North River Road (SR 1359) and Hwy. 441 in Dillsboro, turn left onto SR 1359. Travel approximately 2 miles to TWSA Plant #1 on the left. System Classifications: Primary ORC: Certification: Phone: Secondary ORC(s): On -Site Representative(s): 24 hour contact name On -site representative Related Permits: Inspection Date: 06/17/2014 Primary Inspector: Beverly Price Secondary Inspector(s): Stan D Bryson Stan D Bryson Entry Time: 02:00 PM Reason for Inspection: Routine Permit Inspection Type: Distribution of Residual Solids (503) Facility Status: ■ Compliant ❑ Not Compliant Question Areas: Miscellaneous Questions 0 Pathogen and Vector Attraction (See attachment summary) Exit Time: 03:00 PM Phone: 828-586-9318 Phone: 828-586-9318 Phone: 828-296-4500 Inspection Type: Compliance Evaluation Page: 1 Permit: W00005763 Owner -Facility: Tuckaseigee Water & Sewer Authority Inspection Date: 06/17/2014 Inspection Type: Compliance Evaluation Reason for Visit: Routine Inspection Summary: The inspection included a review of the 2013 Annual Report. 123.25 Dry Tons of product was distributed during 2013. 64.8 tons of sludge were hauled to R and B Landfill in Homer Ga. in 2013. Metals/nutrient and TCLP analyses were completed as required. Metals were within ceiling concentration and monthly average concentration limits. Pathogen and vector attraction reduction requirements appeared to be met based on the data submitted. 3rd Batch - 7/29/13 Calculations were not completed. Please make sure all calculations are completed. Recipient information was included. Please include the degree C or F on the dryer operations daily log. Type Yes No NA NE Land Application n Distribution and Marketing ■ Pathogen and Vector -Attraction Yes No NA NE a. Fecal coliform SM 9221 E (Class A or B) ■ fl Class A, all test must be <1000 MPN/dry gram ■ Geometric mean of 7 samples per monitoring period for class B<2.0*10E6 CFU/dry gram n Fecal coliform SM 9222 D (Class B only) n n ■ n Geometric mean of 7 samples per monitoring period for class B<2.0*10E6 CFU/dry gram n b. pH records for alkaline stabilization (Class A) n n ■ n c. pH records for alkaline stabilization (Class B) n n ■ n Temperature corrected n d. Salmonella (Class A, all test must be < 3MPN/4 gram day) n n ■ n e. Time/Temp on: n n ■ n Digester (MCRT) n Compost n Class A lime stabilization n f. Volatile Solids Calculations n ❑ ■ n g. Bench -top Aerobic/Anaerobic digestion results ❑ ❑ ■ n Comment: Page: 2 • Compliance Inspection Report Permit: WQ0005763 Effective: 10/08/10 Expiration: 07/31/14 Owner: Tuckaseigee Water & Sewer Authority SOC: Effective: Expiration: Facility: TWSA Class A EQ Residuals Production Facility and Distribution Program County: Jackson 1871 N River Rd Region: Asheville Sylva NC 28779 Contact Person: Joe Cline Title: Executive Director Phone: 828-586-5189 Directions to Facility: From the intersection of North River Road (SR 1359) and Hwy. 441 in Dillsboro, turn left onto SR 1359. Travel approximately 2 miles to TWSA Plant #1 on the left. System Classifications: Primary ORC: Certification: Phone: Secondary ORC(s): On -Site Representative(s): Related Permits: Inspection Date: 06/19/2014 Entry Time: 01:00 PM Exit Time: 01:45 PM Primary Inspector: Beverly Price Phone: 828-296-4500 Secondary Inspector(s): Reason for Inspection: Routine Inspection Type: Compliance Evaluation Permit Inspection Type: Distribution of Residual Solids (503) Facility Status: Compliant ❑ Not Compliant Question Areas: Miscellaneous Questions N Record Keeping Treatment Sampling N av,�CAL I-K-L s� h akj 1 A— A a-� -� �Q70� �z�f (See attachment summary) 5 w— d5 d°,-3 5AR r_PJC5 ,cJ (J,f,-c 6q�,C/ Loi rO bi l P�t-tS C`l � � L Z �C1 V, � � (_ urzj Page: 1 � r p � � • � c � G�G�Ir • .- $ Permit: WQ0005763 Owner -Facility: Tuckaseigee Water & Sewer Authority Inspection Date: 06/19/2014 Inspection Type: Compliance Evaluation Reason for Visit: Routine Inspection Summary: j t [ i a-9 C 2© 13 — C-x,.(c s . � Co ►�plL,�� c�,� RID I I Tr C3 0 `,�_ -3 UJ to TES 0"i-e J"El C a w k/\, CV���ST� �I,e3 h� l PCS5 Ct r� __II(,1 - ,c( 6S Page: 2 Permit: WQ0005763 Owner - Facility: Tuckaseigee Water & Sewer Authority Inspection Date: 06/19/2014 Inspection Type: Compliance Evaluation Reason for Visit: Routine Record Keeping Is GW monitoring being conducted, if required? Are GW samples from all MWs sampled for all required parameters? Are there any GW quality violations? Is GW-59A certification form completed for facility? Is a copy of current permit on -site? Are current metals and nutrient analysis available? Are nutrient and metal loading calculating most limiting parameters? a. TCLP analysis? b. SSFA (Standard Soil Fertility Analysis)? Are PAN balances being maintained? Are PAN balances within permit limits? Has land application equipment been calibrated? Are there pH records for alkaline stabilization? Are there pH records for the land application site? Are nutrient/crop removal practices in place? Do lab sheets support data reported on Residual Analysis Summary? Are hauling records available? Are hauling records maintained and up-to-date? # Has permittee been free of public complaints in last 12 months? Has application occurred during Seasonal Restriction window? Comment: Treatment Check all that apply Aerobic Digestion Anaerobic Digestion Alkaline Pasteurization (Class A) Alkaline Stabilization (Class B) Compost Drying Beds D, - j -0,_ - g" � ' i Yes No NA NE nnr�in nnnn nnnn nnnn nnnn n n n nnm�n n n n n nnnn nnnn nnnn nnnn nnnn nnnn nnrbn nnnn nnnn nnnn nnin 0 0 T n Yes No NA NE Y n n n n n Page: 3 Permit: WQ0005763 Owner -Facility: Tuckaseigee Water & Sewer Authority Inspection Date: 06/19/2014 Inspection Type: Compliance Evaluation Reason for Visit: Routine Other n Comment: Sampling lzc Yes No NA NE Describe sampling: o L pp s � "'L Is sampling adequate? -�' o m b act JS ❑ ❑ n S, Jo aR � Is sampling representative? II I fl ❑ rl Uj �R GI.S-P-a --Y1 � �.-�-v", Comment: o`o Page: 4 rim A4itwh�. )OPV NCDENR North Carolina Department of Environment and Natural Resources Division of Water Quality Pat McCrory Thomas A. Reeder John E. Skvarla, III Governor Acting Director Secretary July 10, 2013 Stan Bryson, Wastewater Operations Superintendent Tuckaseigee Water & Sewer Authority 1246 West Main Street Sylva, NC 28779 Subject: Follow-up to May 3, 2013 Compliance Evaluation Inspection Permit No.WQ0005763 Class A EQ Residuals Production Facility & Distribution Program (503) Jackson County Dear Mr. Bryson, On June 28, 2013, staff of the NC Division of Water Quality (DWQ), Aquifer Protection Section (APS), conducted a follow-up to the May 30, 2013 compliance evaluation. We wish to thank you for your assistance during the inspection. The following items were discussed: 1. The SAR calculations for 2011 & 2012 still need to be submitted to the Asheville Regional Office. 2. The Engineering Certification has been submitted. 3. The Operation & Maintenance Plan has been updated but should include: a. Attachment A should be added to the sampling procedures along with the names of the personnel responsible for collecting samples. b. The Spill Control Plan needs to be included. A sample Spill Control Plan is enclosed for your use. 4. The Utilization Agreement has been updated but should include the facility contact information of key personnel for the applicator or party receiving bulk residuals in the event that requirements specified in the utilization agreement are not met. Educational material should also be included with the Utilization Agreement. AQUIFER PROTECTION SECTION — Asheville Regional Office (ARO) 2090 U.S. 70 Highway, Swannanoa, NC 28778-8211 Phone: 828-296-4500 \ FAX: 828-299-7043 Internet www.ncwatergualitv.org An Equal Opportunity 1 Affirmative Action Employer Mr. Bryson July 10, 2013 Page 2 of 2 You are required to address the items above on or before August 10, 2013. If you have any questions concerning this inspection or the necessary corrective measures, you may contact me via email at bev.price@ncdenr.gov or at (828) 296-4685. Sincerely, Beverly Price Environmental Specialist c AR4=APS�FYIes Aquifer Protection Section Central Files 1 i Compliance Inspection Report Permit: WO0005763 Effective: 10/08/10 Expiration: 07/31/14 Owner: Tuckaseigee Water & Sewer Authority SOC: Effective: Expiration: Facility: TWSA Class A EQ Residuals Production Facility and Distribution Program County: Jackson 1871 N River Rd Region: Asheville Sylva NC 28779 Contact Person: Joe Cline Title: Executive Director Phone: 828-586-5189 Directions to Facility: From the intersection of North River Road (SR 1359) and Hwy. 441 in Dillsboro, turn left onto SR 1359. Travel approximately 2'miles to TWSA Plant #1 on the left. System Classifications: Primary ORC: Certification: Phone: Secondary ORC(s): On -Site Representative(s): 24 hour contact name On -site representative Related Permits: Inspection Date: 06/28/2013 Primary Inspector: Beverly Price Secondary Inspector(s): Stan D Bryson Stan D Bryson EntryTime: 10:00 AM Reason for Inspection: Follow-up Permit Inspection Type: Distribution of Residual Solids (503) Facility Status: ❑ Compliant ❑ Not Compliant Question Areas: 0 Miscellaneous Questions (See attachment summary) Exit Time: 11:00 AM Phone: 828-586-9318 Phone: 828-586-5189 Phone: 828-296-4500 Inspection Type: Compliance Evaluation Page: 1 Permit: WQ0005763 Owner -Facility: Tuckaseigee Water & Sewer Authority Inspection Date: 06/28/2013 Inspection Type: Compliance Evaluation Reason for Visit: Follow-up Inspection Summary: The purpose of this site visit was to follow-up on the compliance inspection conducted on May 30,2013. The Engineering Certification has been submitted. The Operation & Maintenance Plan has been updated but should also include the changes that were discussed: 1.Attachment A should be added to sampling procedures along with names of personnel collecting the samples. 2.Spill Control Plan should be added. The Utilization Agreement has been updated but should also include the facility contact information for key personnel for the applicator or party receiving bulk residuals in the event that requirements specified in the utilization agreement are not met. The SAR calculations for 2011 2012 still need to be submitted. Page: 2 Tuckaseigee Water & Sewer Authority Serving Jackson County 1246 West Main Street Sylva, NC 28779 Ph. (828) 586-5189 Fax (828) 631-9089 Aug 28th, 2013 Ms Bev Price Aquifer Protection Section Asheville Regional Office 2090 U.S. 70 Hwy Swannanoa, NC 28788-8211 Subject: Permit No. WQ0005763 Class A EQ Residuals Production Facility & Distribution Program Tuckaseigee Water and Sewer Authority Jackson County Dear Ms Price, Please fmd attached a copy of the e-mail I sent to you with the results of the SAR calculations. I have also included the Utilization Agreement, a copy of our newly created shipping manifest and the updated Operation and Maintenance Plan. Please contact me with any further revisions that need to be made to our record keeping. Sincerely, Stan Bryson Wastewater Plant Operations Supt. Tuckaseigee Water and Sewer Auth. xc: (cover letter) Mr. Dan Harbaugh, Executive Director, Tuckaseigee Water and Sewer Authority RECEIVED SEP Q" 2013 Asheville Regional Office r Mail Page 1 of 1 PPV + Font size - Sar calculations From : sbrysontwsa@frontier.com Subject : Sar calculations To : Bev Price <bev.price@ncdenr.gov> Bev, I have the following SAR calculations for you; 2/14/12= 2.4 8/14/12= 2.7 6/7/12= 2.2 11/13/12=2.4 Wed, Sul 17, 2013 09:16 AM No calculations were available for 2011 or 2010 due to the fact that no residuals were distributed to the public during these years. All sludge generated during thaese years was hauled to the landfill. Was there anything else that I needed to get to you? Thanks Stan Bryson http://webmail.frontier.com/frontiertnail/h/printmessage?id=26659 8/21 /2013 FPV Utilization Agreement These bioresiduals are produced by the Tuckaseigee Water and Sewer Authority under the authority of permit #WQ0005763 as issued by the NC Dept. of Environment and Natural Resources. Info regarding the beneficial reuse of this residual, including application rates, laboratory analysis and spill response procedures may be obtained at: Tuckaseigee Water and Sewer Authority Contact: Stan Bryson TWSA Plant #1 ph: 828-586-9318 1871 North River Rd. Sylva NC 28779 a. By signature and agreeing to accept the bulk class A residuals it is recognized that the application of Class A residuals is allowed under the conditions of this agreement. The application of these Class A residuals is considered the beneficial reuse of a waste under 15A NCAC 02T.1100. The application of these Class A Residuals to the land has been deemed permitted under 15A NCAC.1103(4) provided the conditions of this agreement are met. Any action resulting in the damages to surface waters or groundwater caused by failure to follow the conditions of the agreement is subject to enforcement action by the NC Division of Water Quality. b. The person or entity accepting the Class A residuals shall to the best of their knowledge meet the following application requirements: i. Application of the bulk residuals will stop if it becomes known that the application adversely affects a threatened or endangered species listed under section 4 of the Endangered Species Act or its designated critical habitat. ii. Application of the bulk residuals shall not occur when the land is flooded, frozen, or snow-covered or is otherwise in a condition such that runoff of the residuals would occur. iii. Application of the bulk residuals within the 100 tear flood elevation unless the bulk residuals are injected or incorporated within a 24-hour period following the residuals land application event. Flood elevation information is available at http://www.ncfloodmaps.com/default_swf asp; iv. Application of the bulk residuals shall not occur during a measurable precipitation event (i.e. > .01" per hour) or within 24 hours following a rainfall event of 0.5 inches or greater in a 24 hour period; V. Residuals stockpiled for more than 14 days shall be covered. vi. Application of bulk residuals shall not occur if the vertical separation of the seasonal high water table and the bulk residuals application is less than one foot. vii. Application of bulk residuals shall not occur if the vertical separation of the depth to bedrock and the depth of residuals application is less than one foot. viii. Application of bulk residuals shall not occur within 100 feet of a public or private water supply source; ix. Application of bulk residuals shall not occur within 100 feet of any well with the exception of monitoring wells; x. Application of bulk residuals shall not occur within 25 feet of surface waters. FIV xii. Application of bulk residuals shall not occur if the land fails to assimilate the bulk residuals or the application causes the contravention of surface water or groundwater standards. xiii. Application of bulk residuals shall not occur if the slope for land is greater than 10 percent when bulk residuals are surface applied and if the slope of the land is greater than 18 percent when the bulk residuals are injected or incorporated; xiiii. Application of bulk residuals shall not occur if the pH is not maintained in the soil, residuals, and lime mixture, greater than 6.0, on land application sites onto which residuals are applied. Residuals may be applied to these sites provided that a sufficient amount of lime is also applied to achieve a final pH of the soil mixture of at least 6.0, or if an agronomist provides information indicating that the pH of the soil, residuals, and lime mixture is suited for the specified crop type. xv. If the land does not have an established vegetative cover in accordance with the crop management plan outlined by the local Cooperative Extension Office, the Department of Agriculture and Consumer Services, the Natural Resource Conservation Service, or other agronomist unless the bulk residuals are incorporated within a 24-hour period following the residuals application event or injected. c. The generator of the bulk residuals shall provide information on the proper use of the residuals including information on the nutrient quantities within the residuals and recommended application rates. A copy of the label or information sheet attached to bags or other containers or residuals as specified in condition 111.9. will satisfy this condition. d. The applicator or party receiving bulk residuals from the permittee shall supply all third parties receiving bulk residuals with documentation specifying that application shall occur consistent with the agreement. e. Instructions, including contact information for key personnel, for the applicator or party receiving bulk residuals in the event that requirements specified in the utilization agreement are not met. f. A copy of the utilization agreement shall be maintained at the land application sites when bulk residuals are being applied. g. An education program shall be developed and implemented to inform employees and individuals accepting the residuals of the proper use of residuals. Educational materials shall be provided to all individuals accepting the residuals. The educational material shall be made available to the Division upon request. h. A label shall be affixed should be affixed to the bag or other container in which residuals that are sold or given away for application to the land, and or an information sheet shall be provided to the person who receives the residuals sold or given away in other containers for application to the land. The label or information sheet shall contain the following information: • The name and address of the person who prepared the residuals that is sold or given away in a bag or other container for application to the land. • A statement that application of the residuals to the land is prohibited except in accordance with the instructions on the label or information sheet. • A statement which indentifies that this material shall be prevented from entering any public or private water supply source (including wells) and any stream, lake, or river. • A statement that the residuals shall be applied at agronomic rates and recommended rates for intended uses. Signed: Date Recipient Info: Name: Address: City, State ,Zip Tuckaseigee Water and Sewer Authority Signed: for Date ph: Recipient TWSA Operation and Maintenance Plan For Residual Operations The residual operations at TWSA consist of the following main processes. (a) Aerobic Digestion When sludge is wasted from the sbrs it is routed to one of the two aerobic digestors. The upper digestor (digestor #1) has a capacity of 285,000 gals. The lower digestor (digestor #2) has a capacity of 345,000 gals. The operator can route sludge flow to the digestors from the waste sludge pumps in the sbrs by using the valves on the waste sludge line. The valves and associated sludge piping are shown on Sheet C5 of the record drawings by McGill Assoc. dated 10/12/2012. (b) Sludge Pump The sludge pump for the belt press is a progressive cavity pump (type BN 52-6Ls/A1-C1-C6-F0-SA-X) manufactured by Seepex Inc and rated for a pump rate of 100 gpm. The pump is located in the basement of the sludge pump/reusewater pump building. The location of this building on the site is shown on Sheet C3 of the record drawings by McGill Assoc. dated 10/12/2012. The details of the piping are shown on Sheet M21 of the record drawings by McGill Assoc. dated 10/12/2012. All lubrication and operation and maintenance of this equipment should adhere to the schedules set by Seepex Inc. These procedures are documented in the operation and maintenance manual supplied to TWSA by Seepex and dated September 2010. (c) Belt Press The belt press is a 1.0 meter capacity (model #GRS-1 Series III ) as manufactured by Komline-Sanderson. The press is located in the bottom of the Lab/Dryer building. All lubrication and operation and maintenance of this equipment should adhere to the schedules set by Komline-Sanderson. These procedures are documented in the operation and maintenance manual supplied to TWSA by Komline- Sanderson. (d) Polymer System The polymer system is a DynaBLEND model # L4S-1200-3P-13-3(Disc) supplied by Fluid Dynamics. The pump is located in a corner of the dryer/press building adjacent to the belt press. All lubrication and operation and maintenance of this equipment should adhere to the schedules set by Fluid Dynamics. These procedures are documented in the operation and maintenance manual supplied to TWSA by Fluid Dynamics. (e) Sludge Conveyors Information on screw conveyors and components can be found in the Fenton Operation and Maintenance Manual. (f) Sludge Storage Hopper The sludge storage hopper is located between the belt press and the sludge dryer and is used for storing dewatered sludge in preparation for batching to the dryer. (g) Burner The thermal fluid heater is manufactured by Fulton and is located adjacent to the dryer in the dryer/press building. Complete technical specifications and operation and maintenance information can be found in Volume 4 of the owner manuals supplied by Fenton to TWSA. (h) Dryer The dryer is a Fenix 48/10 manufactured by Fenton Environmental Technologies and is located in the dryer/press building. Complete operation and maintenance information can be found in the four (4) volume set supplied to TWSA by Fenton Environmental Technologies. (i) Silo and Baghouse system The Silo and Baghouse were manufactured and supplied to Fenton Environmental by GMD Environmental Technologies of Fort Worth, Texas. Complete operation and maintenance information can be found in volume three (3) of the four (4) volume set supplied to TWSA by Fenton Environmental Technologies. Belt Press Operations • The belt press augers should be turned on and allowed to run. Controls for these augers are accessed through the Allen Bradley Panel View Plus 1000 touch screen dryer panel. • Turn control power on at the belt press panel. After a delay the alarm will sound. Hit reset button to silence the alarm. Pull on the washwater pump, hydraulic pump and belt switch in that order. Confirm that all equipment is operating properly. • Turn polymer pump on at the DynaFlow pump control panel. Speed of the pump will be adjusted based upon observations made at the press. • Turn sludge pump on by pulling the sludge pump button on the belt filter control panel. Pump feed rate is adjusted at the SPACP 550 panel located on the concrete column adjacent to the belt press. When the polymer begins to form a good floc in the sludge, close valve on mixing tank and write flow reading down on flow meter. Polymer feed rate and sludge feed rate should be adjusted to contain all of the product in the pressure zone of the belt and to produce the driest cake possible and still "turn loose" from the belt at the scraper above the auger. • At the end of the shift or days run, reverse the start up procedure to shut down the press. The daily log sheet has spaces for recording the hours operated and gallons of sludge dewatered. Care should be taken to properly fill out all information so operations can be properly tracked. • When it becomes necessary to change out a drum of polymer it is important to note the change and the flow reading on the daily sheet. This info is used to calculate dewatering costs. Dryer Operation Dryer controls are all contained in the Allen Bradley Panel View Plus 1000 panel . Each day the dryer is operated a Dryer Operations Daily Record should be completed. Dryer operations should be conducted as follows: • Dryer should be set to auto on touch panel screen. Record start time. Burner will activate and start building temperature. When a pre -determined temperature is reached fill cycle will start. • Record fill cycle start time. • After the timed fill cycle is complete, dry cycle will start. Record dry cycle start time. • Dry cycle timer will be on zero at dry cycle start time. Record temperatures as outlined on Daily Record at 50 min intervals until end of dry cycle. (Approx. 200 mins) • At the end of the dry cycle, the discharge cycle will start. Discharge cycle will last approx. 10 min and a new fill cycle will start. • When the last batch of sludge to be dried for the day is in the dryer, set control mode to Automatic Cool Down. This will prevent another batch from being loaded to the dryer and at the end of the cycle the dryer will go into cool down mode in preparation of shutting down. Silo and Baghouse Operation The controls of the baghouse should be set to auto on the panel adjacent to the silo. When the dryer discharges a batch to the silo the baghouse blower will automatically come on and keep dust from being discharged to the atmosphere. Periodic cleaning of the dust bin on the baghouse is required, this is accomplished by placing the backhoe bucket under the chute and opening the slide gate to allow dust to slide into the bucket. Some tapping on the side of the hopper with a rubber mallet may be required to loosen the accumulated dust. Sampling Procedures Daily sampling should be conducted in various points throughout the process to track and to verify compliance with permitted values. Plant operators shall be responsible for taking samples at the proper times and at the designated locations. Daily • At least once per day a sample of the raw sludge feed to the belt press should be taken. This sample should be a composite of several samples taken at different times during the day. This sample should be obtained from the sample port at the intake to the raw sludge pump in the basement of the reuse water/sludge pump building. This sample should be kept in a container with an airtight lid until analyzed to prevent evaporation. • At least once per day a sample of the dewatered sludge cake should be taken from the belt filter press. This sample should be a composite of several samples taken at different times during the day. This sample should be kept in a container with an air tight lid until analyzed to prevent evaporation. Each batch of sludge discharged from the dryer should be sampled. This sample can be obtained after the discharge of each batch from the sampling port on the side of the discharge auger. This sample is hot when first obtained from the auger and should be allowed to cool before being bagged. All of the above samples should be weighed and dried overnight in order to obtain total % solids values. Reference should be made to the laboratory SOP manual for proper procedures for analysis for total % solids. Operators will be provided training in the proper procedures for sampling, storage and analysis of samples before they are expected to conduct analysis. Quarterly Quarterly sampling should be conducted on a representative sample of the dried residuals. This sample analysis is contracted with Pace Analytical of Asheville NC, and should be sampled, preserved and delivered to them within their required parameters. The following analysis should be conducted on this sample. Aluminum (Al) Mercury (Hg) Arsenic (Ar) Molybdenum (Mo) Cadmium (Cd) Nickel (Ni) Calcium (Ca) ph Chromium (Cr) Potassium (K) Copper (Cu) Sodium (Na) Lead (Pb) Selenium (Se) % total solids Corrosivity Fecal Coliform mpn/g/solid* Ignitability Total Nitrogen (N) Reactivity Total Phosphorous (P) Ammonia Nitrogen (Nh3-N) Plant available Nitrogen(PAN) (surface applied) Calculated Sodium Adsorption Rate (SAR) Magnesium (Mg) Zinc (Zn) * A total of at least seven (7) coliform samples should be analyzed annually. Annually Annually, a TCLP(toxicity characteristic leaching procedure) should be conducted on a representative sample of the dried residual. This sample analysis is also conducted by Pace Analytical. Truck Loading Operations Trucks to be loaded with bioresidual should pull through under the silo. Drivers will be responsible for positioning of their trucks and plant operators will be responsible for loading operations. The storage silo control panel is located at the top of the stairs on the silo. This should be switched to the on position to enable the dust collector blower and chute controls to work. The valve on the green air piping to the rotary valve dispenser on the silo should be in the open position during truck loading operations. The operator should lower the end of the chute to the bed of the truck and then switch on the rotary valve dispenser. The shorter distance residuals have to fall from the end of the chute to the bed of the truck dramatically lessens the amount of dust escaping during the loading process. Paperwork All users of the bioresiduals must sign and date a Utilization Agreement before taking or possessing the product. This agreement between TWSA and the end user must be signed and dated within one year by both parties. The hauler or transporter should be given a copy of the signed shipping manifest. The manifest should include an estimated tonnage and should list contact info for the generator and the user along with contact info on the trucking company with places for the generator, hauler and end user to sign. Info as to the proper procedures and safeguards should an accident or spill occur should be included on the manifest. TWSA NON-HAiARDOUStM M. :Generat6r;_. Generator's Mailing Address: Generator's Site Address (if different than mailing): Emergency Contact incase of Accidental Spill Tuckaseigee-Water drid-SeWer Auth-. .-.,; 1246 West' MainSt,- :'iVltNorth,Rive'r Rd. M* 71: 006m,5:001pm �ph: 828_508-1072 SYLVA, NC 28779 SYLVA:;- NC:28779-`*:'2 After tHiouf§-TWSA OfiCall ph: 828-586"51Aq'-"-::" 8-:5. '6�§Aig 06 82i �8 �'928SO6-068'1 Residuals Info These residuals are not Hazardous Waste as defined by;'46&kPa`rt`'261`or . anytii6plica131e7atei'IaW. Information and instructions in case of accidental spill are on the back of this document. Date: ,'.',..Estimated Load Sizqtons: Transporter,'sMailing Address Transporte r,,s,Dri%(0rl fo Eme rgeqq,Contact, in case of Accident or Spill; Name: Driver Name: name: ph#: Address: or City, h DnVerP one#.,- State,Zip'' name:': PH: Truck ID 1ph#- D'Ostihatibrilhfd Residuals to be Delivered To: Emergency Contact in case of Actiderif.6 r. SP:'i I U,':y Physical Address: name::: City: Contact: name: State Zip PH: 1ph#: Certificate ,1Generators I hereby certify that the above-describ�eqjnaterials are not.hazardous,wastes as define4by 4,DCFR Part 261 or any, applicable state law, have been fully and accurately!cescribed,.classified.,andpackaged and are inprqpj@�_, dition for transportation.according to,applicable,regqlations. Tuckaseigee Water and Sewer u [Authority,� Signature "On behalf of" Month Day..,. Yr .,;.Transporter Acknow ledge,otgece.ipt,of -Materials, Printed Name- Signature" Month' �";Yr 77 ftif 0-Atabf Pde6i0t`andfift81:Dis;P By ihe:b uAk;dlasSA te`§idue[I's�,it--,ig,-rtcogniied'thgt thd app-liciffibb'Of Cl6s&'A,,-, residuals is allowed under the conditions of the utilization agreement. The application of these-ClassA ; :,:o, residuals is considered the beneficial reuse of a waste under 15A NCAC. 1103 (4) provided the conditions of this agreement are met. Any action resulting in the damages to surface waters or groundwater caused by failure to follow the conditions of the utilization agreement is subject to enforcement action by the NC Division of Water Quality Printed Name I Signature Day Yr r7L I ,Spill Response.•Plan-, In the event of a spill, the following actions shall be taken immediately. (1) Management of spill clean -bp activities The transporter should .take immediate charge and initiate clean-up activities., If there -is danger to motorists,.the:general public or employees the first,call should be to 911 so emergency services and .. ,araffic control,can be routed to the site as soon as possible. If additional labor and equipment is- required- required; assistance may be requested from the NC.DOT or other private contractors as necessary. _. (2) Halt the source of the'spill `Such as a rupture or container or damaged. transport unit. : (3) Contain the spill Form a barrier. Sufficient quantities of straw shall be used for such purposes. Earthen barriers may be. constructed.to. augment'tlie.straw bale containment area of the spilL.The transporter.or..the_person ..:. __. . in charge"on the spill.site will advise.the..clean-up `personneI where to get the. straw, lime and other _. items necessary -to complete th;e clean-up operation, i.e. local farmers, farm'supply centers, n'urseries,• etc. (4) Clean-up Employ front-end loaders, vacuum equipment, sludge application. vehicles and/or local septic tank service to remove as much of the spilled material as possible. Straw and/or sand should be scattered in,. the spill area to soak up the remaining material. The straw -and -sand -soaked material will be collected and removed to 'a disposal area approved" by- representatives of the, -state regulatory agency. (5). Final, Clean-up...:.,.: Employ rotary.brush sweeper if needed, and apply lime to the spill area. Clean up will be completed . to the satisfaction of the property owner and state regulatory representatives. The ultimate goal will be to restore the area to its original condition if possible. .(6) Notification As soon as possible after the spill occurs, the transporter will notify the TWSA Wastewater Operations Staff at (828-586-9318) or if after hours the TWSA ON -Call employee at (828-506-0681). The operator or on -'call employee will notify the WWT Superintendent. .......... The TWSA Superintendent or their designee will notify the Asheville Regional Office of the NCDENR by telephone (828-296=4500) as soon as possible, but"not mor&than 24 hours•after the occurrence. If after hours, weekends or holiday the State Emergency Operations phone ..number (828-858-0368) shall be used for notification. The transporter shall provide a written report within 48 hours of the spill to the TWSA WWTP Superintendent:detailing: the: information and actions taken. related "t6 the spill TWSA personnel will file a,written report,to the. Asheville Regional office of the NCDENR within five -days of.the . . spill occurrence. SAR & ESP Sodium Absorption Ratio Na: Sodium (Mg/L) Equivalent weight: 23 Ca: Calcium (Mg/L) Equivalent weight: 20 Mg : Magnesium (Mg/L) Equivalent weight: 12 Milli Equivalent = Mg/L / Equivalent weight Na M /L Ca M /L M M /L 1048 1 11107 1668 Na (ME) Ca (ME) Mg (ME) 45.56522 1 555.35 1 139 SAR= Na Milli Equivalent/[0.5 X (Ca Milli Equivalent + Mg Milli equivalent)]0.5 power SAR = 2.445452 (From Mg/L entered above) SAR= #DIV/01 (From ME entered below) Na ME Ca ME I Mg (ME) Exchangeable Sodium Percentage ESP = Na (Milli Equivalents) / CEC X 100 The percentage of sodium ions occupying the ESP = 15923.915 % Na on INC soil test is 2a0- S cpks CO as meq. Na LMEJCEC 1184.783 20 11-3 /; //0 tX1- 6110 aAQ- The amount of exchangeable sodium ions versus the amount of exchangeable calcium & magnesium ions in a given material. Permitting guidance is if greater than 10 require ESP in permit. cation exchange complex of soils Should be less than 15% (15-20%) 11C&DENR North Carolina Department of Environment and Natural Resources Division of Water Quality Pat McCrory Charles Wakild, P. E. John E. Skvarla, III Governor Director Secretary June 3, 2013 Stan Bryson, Wastewater Operations Superintendent Tuckaseigee Water & Sewer Authority 1246 West Main Street Sylva, NC 28779 Subject: Notice of Deficiency NOD-2013-PC-0220 Permit No.WQ0005763 Class A EQ Residuals Production Facility & Distribution Program (503) Jackson County Dear Mr. Bryson, On May 30, 2013, staff of the NC Division of Water Quality (DWQ), Aquifer Protection Section (APS), inspected the subject Class A EQ Residuals Production & Distribution Facility. We wish to thank you for your assistance during the inspection. The purpose of the visit was to conduct a compliance inspection. The following items were deficient at the time of the inspection. (Also please refer to the attached inspection report): 1. The residuals analysis that was conducted in 2012 did not include the SAR calculation. The SAR calculation was also missing from the 2011 Annual Report (noted in the 2012 inspection). 2. The Engineering Certification has not been submitted for the upgraded residuals facility. n/3. The Operation & Maintenance Plan has not been completed. ✓ 4. The Utilization Agreement should also include permit conditions III.4.b.v & ix.; c e. and f.; 9. & 11. Please contact Bev Price @ bev.nricegncdenr.gov. for guidance with this Agreement. You are required to take corrective measures regarding the items above on or before June 28, 2013. As we discussed during the inspection, a follow up inspection is scheduled for June 28, 2013. Please note that failure to comply with the State's rules, in the manner and time specified, may result in the assessment of additional civil penalties and/or the use of other enforcement mechanisms available to the State. AQUIFER PROTECTION SECTION — Asheville Regional Office (ARO) 2090 U.S. 70 Highway, Swannanoa, NC 28778-8211 Phone: 828-2964500 FAX: 828-299-7043 Internet: www.ncwaterquality.orct An Equal Opportunity 1 Affirmative Action Employer Mr. Bryson NOD-2013-PC-0220 June 3, 2013 Page 2 of 2 If you have any questions concerning this inspection or the necessary corrective measures, you may contact me via email at bev.price@ncdenr.gov or at (828) 296-4685. Sincerely, Beverly Price Environmental Specialist AO=APSR escc f.tAqu rocion Section Central Files Compliance Inspection Report Permit: WQ0005763 Effective: 10/08/10 Expiration: 07/31/14 Owner: Tuckaseigee Water & Sewer Authority SOC: Effective: Expiration: Facility: TWSA Class A EQ Residuals Production Facility and Distribution Program County: Jackson 1871 N River Rd Region: Asheville Sylva NC 28779 Contact Person: Joe Cline Title: Executive Director Phone: 828-586-5189 Directions to Facility: From the intersection of North River Road (SR 1359) and Hwy. 441 in Dillsboro, turn left onto SR 1359. Travel approximately 2 miles to TWSA Plant #1 on the left. System Classifications: Primary ORC: Certification: Phone: Secondary ORC(s): On -Site Representative(s): 24 hour contact name On -site representative Related Permits: '- Inspection Date: 05/30/2013 Primary Inspector: Beverly Price Secondary Inspector(s): Stan D Bryson Stan D Bryson Entry Time: 10:50 AM Reason for Inspection: Routine Permit Inspection Type: Distribution of Residual Solids (503) Facility Status: 0 Compliant ■ Not Compliant Question Areas: Miscellaneous Questions 0 Record Keeping (See attachment summary) Exit Time: 12:00 PM Phone: 828-586-9318 Phone: 828-586-5189 Phone: 828-296-4500 Inspection Type: Compliance Evaluation Treatment ■ Pathogen and Vector Attraction Page: 1 Permit: W00005763 Owner -Facility: Tuckaseigee Water & Sewer Authority Inspection Date: 05/30/2013 Inspection Type: Compliance Evaluation Reason for Visit: Routine Inspection Summary: The inspection included a tour of the facility as well as a review of the 2012 Annual Report (AR). The SAR calculation was missing from the 2012 AR. The SAR should also be submitted for the 2011 AR. The Engineering Certification has not been submitted for the upgraded WWTP residuals facility. The Operation & Maintenance Plan has not been completed. The Utilization Agreement should be updated to conform to the permit conditions. Notice of Deficiency (NOD) will be issued for the items listed above. A follow-up inspection has already been scheduled for June 28, 2013. Scott Carpenter (Soil Plus) is currently land applying most of the residuals produced at this facility. Two loads have been hauled this year. Two loads of residuals have been hauled to the landfill in Homer, Ga. so far this year. Hauling tickets on site for Waste Management. Page: 2 Permit: WQ0005763 Owner -Facility: Tuckaseigee Water & Sewer Authority Inspection Date: 05/30/2013 Inspection Type: Compliance Evaluation Reason for Visit: Routine Type Yes No NA NE Land Application ❑ Distribution and Marketing ■ Record Keeping Yes No NA NE Is GW monitoring being conducted, if required? ❑ ❑ ■ ❑ Are GW samples from all MWs sampled for all required parameters? ❑ ❑ ■ ❑ Are there any GW quality violations? ❑ ❑ ■ ❑ Is GW-59A certification form completed for facility? ❑ ❑ ■ ❑ Is a copy of current permit on -site? ■ ❑ Cl Cl Are current metals and nutrient analysis available? ■ ❑ ❑ ❑ Are nutrient and metal loading calculating most limiting parameters? ■ ❑ ❑ .❑ a. TCLP analysis? ■ ❑ ❑ ❑ b. SSFA (Standard Soil Fertility Analysis)? ■ ❑ ❑ ❑ Are PAN balances being maintained? ❑ ❑ ■ ❑ Are PAN balances within permit limits? ❑ ❑ ■ ❑ Has land application equipment been calibrated? ❑ ❑ ■ ❑ Are there pH records for alkaline stabilization? ❑ ❑ ■ ❑ Are there pH records for the land application site? ❑ ❑ ■ ❑ Are nutrient/crop removal practices in place? ❑ ❑ ■ ❑ Do lab sheets support data reported on Residual Analysis Summary? ■ ❑ ❑ ❑ Are hauling records available? ■ ❑ ❑ ❑ Are hauling records maintained and up-to-date? ■ ❑ ❑ ❑ # Has permittee been free of public complaints in last 12 months? ■ ❑ ❑ ❑ Has application occurred during Seasonal Restriction window? ❑ ❑ ■ ❑ Comment: Pathogen and Vector Attraction Yes No NA NE a. Fecal coliform SM 9221 E (Class A or B) ■ ❑ ❑ ❑ Class A, all test must be <1000 MPN/dry gram ■ Geometric mean of 7 samples per monitoring period for class B<2.0"10E6 CFU/dry gram ❑ Fecal coliform SM 9222 D (Class B only) ❑ ❑ ■ ❑ Page: 3 Permit: W00005763 Owner -Facility: Tuckaseigee Water & Sewer Authority Inspection Date: 05/30/2013 Inspection Type: Compliance Evaluation Reason for Visit: Routine Geometric mean of 7 samples per monitoring period for class B<2.0*10E6 CFU/dry gram n b. pH records for alkaline stabilization (Class A) n ❑ ■ n c. pH records for alkaline stabilization (Class B) n n ■ n Temperature corrected n d. Salmonella (Class A, all test must be < 3MPN/4 gram day) n n ■ n e. Time/Temp on: Q n ■ Digester (MCRT) n Compost Q Class A lime stabilization n f. Volatile Solids Calculations 130011 g. Bench -top Aerobic/Anaerobic digestion results n 0 ■ Q Comment: Treatment Yes No NA NE Check all that apply Aerobic Digestion ■ Anaerobic Digestion n Alkaline Pasteurization (Class A) Alkaline Stabilization (Class B) n Compost n Drying Beds n Other ■ Comment: dryer Page: 4 Ali Z,/ "A NCDENR North Carolina Department of Environment and Natural Resources Beverly .Eaves Perdue Governor Division of Water Quality Charles Wakild, P. E Director June 8, 2012 Stan Bryson, Wastewater Operations Superintendent Tuckaseigee Water & Sewer Authority 1246 West Main Street Sylva, NC 28779 Subject: Notice of Deficiency NOD-2012-PC-0090 Permit No.WQ0005763 TWSA Wastewater Treatment Plant No Class A Residuals Distribution Jackson County Dear Mr. Bryson, Dee Freeman Secretary On May 22, 2012, staff of the NC Division of Water Quality (DWQ), Aquifer Protection Section (APS), inspected the subject Class A Residuals Distribution System. We wish to thank you for your assistance during the inspection. The purpose of the visit was to conduct a compliance inspection. The following items were deficient at the time of the inspection. (Also please refer to the attached inspection report): 1. A fecal coliform sample was collected in February 2012 as part of the requirement for verification of Pathogen Reduction. The sample did not meet the required hold time of 24 hours. Monitoring requirements are included by reference in permit Condition IV.6. 2. The Engineering Certification has not been submitted for the upgraded residuals facility. You are required to take corrective measures regarding the items above on or before July 8, 2012. Please send a letter to our office outlining the measures taken to address these issues. Please note that failure to comply with the State's rules, in the manner and time specified, may result in the assessment of additional civil penalties and/or the use of other enforcement mechanisms available to the State. In addition the following observations were noted: 1. The residuals analysis that was conducted in February did not include the SAR calculation. This calculation should be completed and the results reviewed according to permit Condition II. 10. 2. The Operation & Maintenance Plan should be finished. 3. The Utilization Agreement should also include permit conditions III.13.b., c., g., h. & i. 4. Realistic Yield Expectations (RYE) for determining agronomic rates should be determined using one of the methods listed in permit Condition II.8. One AQUIFER PROTECTION SECTION —Asheville Regional Office (ARO) NorthCarolina 2090 U.S. 70 Highway, Swannanoa, NC 28778-8211 Phone: 828-296-45001 FAX: 828-299-7043 Naturally Internet: www.ncwaterguality.org Mr .Bryson NOD-2012-PC-0090 June 8, 2012 Page 2 of 2 If you have any questions concerning this inspection or the necessary corrective measures, you may contact me via email at bev.price@ncdenr.gov or at (828) 296-4685. Sincerely, Beverly Price Environmental Specialist cc: <A&0--1PS-r4les Aquifer Protection Section Central Files Compliance Inspection Report Permit: WQ0005763 Effective: 10/08/10 Expiration: 07/31/14 Owner: Tuckaseigee Water & Sewer Authority SOC: Effective: Expiration: Facility: TWSA Class A EQ Residuals Production Facility and Distribution Program County: Jackson 1871 N River Rd Region: Asheville Sylva NC 28779 Contact Person: Joe Cline Title: Executive Director Phone: 828-586-5189 Directions to Facility: From the intersection of North River Road (SR 1359) and Hwy. 441 in Dillsboro, turn left onto SR 1359. Travel approximately 2 miles to TWSA Plant #1 on the left. System Classifications: Primary ORC: Certification: Phone: Secondary ORC(s): On -Site Representative(s): 24 hour contact name On -site representative Related Permits: Inspection Date: 05/22/2012 Primary Inspector: Beverly Price Secondary Inspector(s): Stan D Bryson Stan D Bryson EntryTime: 10:00 AM Reason for Inspection: Routine Permit Inspection Type: Distribution of Residual Solids (503) Facility Status: ❑ Compliant ■ Not Compliant Question Areas: 0 Miscellaneous Questions 0 Record Keeping (See attachment summary) Exit Time: 11:30 AM Phone: 828-586-5189 Phone: 828-586-9318 Phone: 828-296-4500 Inspection Type: Compliance Evaluation Treatment ■ Pathogen and Vector Attraction Page: 1 Permit: WQ0005763 Owner -Facility: Tuckaseigee Water & Sewer Authority Inspection Date: 05/22/2012 Inspection Type: Compliance Evaluation Reason for Visit: Routine Inspection Summary: Residuals were not distributed in 2011 as the WWTP was undergoing an upgrade. All residuals were landfilled. This was noted in the Annual Report. The Fenton Dryer is now operational. The Engineering Certification has not been submitted. Fecal coliform sample anayzed in February did not meet the required hold time. The SAR calculation should be completed as it is required for the residuals analysis. This was not included in the February residuals analysis. Reminder: PAN should be land applied at or below agronomic rates. Agronomic rates shall be based on Realistic Yield Expectations (RYE). Sources for RYE are listed in the permit - See Permit Condition 11.8. The Operation & Maintenance Plan (O&M Plan) needs to be completed for this facility - See Permit Condition 111.3. Utilization Agreement/Handout: The following conditions should be added: Condition III. 13. b. c. g. h. & i. Page: 2 Permit: WQ0005763 Owner - Facility: Tuckaseigee Water & Sewer Authority Inspection Date: 05/22/2012 Inspection Type: Compliance Evaluation Type Land Application Distribution and Marketing Record Keeping Is GW monitoring being conducted, if required? Are GW samples from all MWs sampled for all required parameters? Are there any GW quality violations? Is GW-59A certification form completed for facility? Is a copy of current permit on -site? Are current metals and nutrient analysis available? Are nutrient and metal loading calculating most limiting parameters? a. TCLP analysis? b. SSFA (Standard Soil Fertility Analysis)? Are PAN balances being maintained? Are PAN balances within permit limits? Has land application equipment been calibrated? Are there pH records for alkaline stabilization? Are there pH records for the land application site? Are nutrient/crop removal practices in place? Do lab sheets support data reported on Residual Analysis Summary? Are hauling records available? Are hauling records maintained and up-to-date? # Has permittee been free of public complaints in last 12 months? Has application occurred during Seasonal Restriction window? Comment: Pathogen and Vector Attraction a. Fecal coliform SM 9221 E (Class A or B) Class A, all test must be <1000 MPN/dry gram Geometric mean of 7 samples per monitoring period for class B<2.0*10E6 CFU/dry gram Fecal coliform SM 9222 D (Class B only) Reason for Visit: Routine Yes No NA NE ■ Page: 3 Permit: W00005763 Owner -Facility: Tuckaseigee Water & Sewer Authority Inspection Date: 05/22/2012 Inspection Type: Compliance Evaluation Reason for Visit: Routine Geometric mean of 7 samples per monitoring period for class B<2.0*10E6 CFU/dry gram n b. pH records for alkaline stabilization (Class A) n n ■ n c. pH records for alkaline stabilization (Class B) n n M n Temperature corrected n d. Salmonella (Class A, all test must be < 3MPN/4 gram day) n n M n e. Time/Temp on: n 0 M n Digester (MCRT) n Compost n Class A lime stabilization n f. Volatile Solids Calculations n n M n g. Bench -top Aerobic/Anaerobic digestion results n n o Comment: Fecal sample collected in February was analyzed out of Hold Time. Treatment Yes No NA NE Check all that apply Aerobic Digestion Anaerobic Digestion n Alkaline Pasteurization (Class A) n Alkaline Stabilization (Class B) n Compost n Drying Beds n Other Comment: Fenton Dryer. Page: 4 Price, Bev From: Wessner, Alice Sent: Thursday, June 07, 2012 10:23 AM To: Price, Bev Subject: RE: WQ00005763 Reduced TCLP Monitoring S I just changed the monitoring requirements from quarterly to annually in BIMs so they will not get any violations. Alice M. Wessner Environmental Engineer Land Application Unit Aquifer Protection Section Division of Water Quality 1636 Mail Service Center Raleigh, NC 27699-1636 919-807-6425 919-807-9496 (fax) http://h2o.enr.state.nc.us/aps/lau.htm From: Price, Bev Sent: Thursday, June 07, 2012 10:21 AM To: Wessner, Alice Subject: RE: WQ00005763 Reduced TCLP Monitoring No problem. They will be very happy. Sorry I missed it on the Draft. Bev Price - Bev.Price@ncdenr.gov North Carolina Dept. of Environment and Natural Resources Asheville Regional Office Division of Water Quality - Aquifer Protection Section 2090 U.S. 70 Highway Swannanoa, NC 28778 Tel: 828-296-4500 Fax: 828-299-7043 Notice: E-mail correspondence to and from this address may be subject to the North Carolina Public Records Law and may be disclosed to third parties. From: Wessner, Alice Sent: Thursday, June 07, 2012 10:16 AM To: Price, Bev Subject: RE: WQ00005763 Reduced TCLP Monitoring Oh boy, I think I need to do a permit correction. Yes, you are correct, the TCLP monitoring is annually no matter what the dry tons. Thanks for catching this. When I do the correction I will also add in that missing paragraph that we were speaking of yesterday. Sorry. I hate making mistakes! Alice M. Wessner Environmental Engineer Land Application Unit Aquifer Protection Section Division of Water Quality 1636 Mail Service Center Raleigh, NC 27699-1636 919-807-6425 919-807-9496 (fax) http://h2o.enr.state.nc.us/aps/lau.htm From: Price, Bev Sent: Thursday, June 07, 2012 10:12 AM To: Wessner, Alice Subject: RE: WQ00005763 Reduced TCLP Monitoring ok Bev Price - Bev.Price@ncdenr.Rov North Carolina Dept. of Environment and Natural Resources Asheville Regional Office Division of Water Quality - Aquifer Protection Section 2090 U.S. 70 Highway Swannanoa, NC 28778 Tel: 828-296-4500 Fax: 828-299-7043 Notice: E-mail correspondence to and from this address may be subject to the North Carolina Public Records Law and may be disclosed to third parties. From: Wessner, Alice Sent: Thursday, June 07, 2012 10:12 AM To: Price, Bev Subject: RE: WQ00005763 Reduced TCLP Monitoring Wait. Let me verify my last email before you say anything to anyone... Alice M. Wessner Environmental Engineer Land Application Unit Aquifer Protection Section Division of Water Quality 1636 Mail Service Center Raleigh, NC 27699-1636 919-807-6425 919-807-9496 (fax) http://h2o.enr.state.nc.us/aps/lau.htm rom: Price, Bev Sent: Thursday, June 07, 2012 10:00 AM To: Wessner, Alice Subject: RE: WQ00005763 Reduced TCLP Monitoring Alice, I didn't realize the frequency for TCLP in this permit went from Annual to Quarterly with the permit modification in 10/2010. 1 discovered this when I did their inspection two weeks ago; did not catch it in the Draft review either. They have been landfilling their residuals for the last two years so it has just become an issue. Should it have jumped so drastically? Inquiring on behalf of the permittee as this is a very expensive test. Bev Bev Price - Bev.Price@ncdenr.gov North Carolina Dept. of Environment and Natural Resources Asheville Regional Office Division of Water Quality - Aquifer Protection Section 2090 U.S. 70 Highway Swannanoa, NC 28778 Tel: 828-296-4500 Fax: 828-299-7043 Notice: E-mail correspondence to and from this address may be subject to the North Carolina Public Records Law and may be disclosed to third parties. From: Wessner, Alice Sent: Wednesday, June 06, 2012 2:45 PM To: Price, Bev Subject: RE: WQ00005763 Reduced TCLP Monitoring There was a mistake in this permit. This should have been included in the permit: Once the residuals have been monitored for two years at the frequency specified in Attachment A, the Permittee may submit a permit modification request to reduce the frequency of this monitoring requirement. In no case shall the monitoring frequency be less than once per permit cycle. Thanks for catching it. I will need to issue a permit correction but I wonder how that would work since this is from 2010. I can ask Jon. Alice M. Wessner Environmental Engineer Land Application Unit Aquifer Protection Section Division of Water Quality 1636 Mail Service Center Raleigh, NC 27699-1636 919-807-6425 919-807-9496 (fax) http://h2o.enr.state.nc.us/aps/lau.htm From: Price, Bev Sent: Wednesday, June 06, 2012 2:35 PM To: Wessner, Alice Subject: WQ00005763 Reduced TCLP Monitoring Hi Alice, The subject permittee is inquiring about reduced monitoring for TCLP. Currently they are required to monitor quarterly. Most permits have language about reduced monitoring and this one does for residuals but not TCLP. Do you think the language is referring to TCLP as well as residuals? This might be a question for Chonticha or Ed but I thought I would start with you as the permit writer; feel free to pass along to right person. Hope you are doing well and thanks for your help as always. Bev Bev Price - Bev.Price@ncdenr.gov North Carolina Dept. of Environment and Natural Resources Asheville Regional Office Division of Water Quality - Aquifer Protection Section 2090 U.S. 70 Highway Swannanoa, NC 28778 Tel: 828-296-4500 Fax: 828-299-7043 Notice: E-mail correspondence to and from this address may be subject to the North Carolina Public Records Law and may be disclosed to third parties. O o,l, Liu -3 Vv\c-A F.TO-t43q-7:Z?5- jct -7C- 7, o 9- 367- 6 VS-,S- Jon - '": '-5777-771 r 51 q.® C Fir—, . Pam-. La Compliance Inspection Report Permit: WQ0005763 Effective: 10/08/10 Expiration: 07/31/14 Owner: Tuckaseigee Water & Sewer Authority SOC: Effective: Expiration: Facility: TWSA Class A EQ Residuals Production Facility and Distribution Program County: Jackson 1871 N River Rd Region: Asheville Sylva NC 28779 Contact Person: Joe Cline Title: Executive Director Phone: 828-586-5189 Directions to Facility: From the intersection of North River Road (SR 1359) and Hwy. 441 in Dillsboro, turn left onto SR 1359. Travel approximately 2 miles to TWSA Plantf#1 on the left. System Classifications: Primary ORC: Certification: Phone: Secondary ORC(s): On -Site Representative(s): 24 hour contact name Stan D Bryson Phone: 828Z86.54Z9 Related Permits: Inspection Date: �I1g'2©(2 Entry Time: Exit Time: Primary Inspector: Beverly Price Phone: 828-296-4500 Secondary Inspector(s): Reason for Inspection: Routine Inspection Type: Compliance Evaluation Permit Inspection Type: Distribution of Residual Solids (503) Facility Status: Q Compliant 54 Not Compliant .J(- F.,eAk P_6 Lj Question Areas: Miscellaneous Questions E Record Keeping Treatment ■ Pathogen and Vector Attraction NOD - 2012- f C-i0C°►0 w Vvs;d.Ua,.i,S w- all. k",Cw A _dL4a---C ( (See attachment summary) '^ -7, I. j °^ — a' sol ,I So,< eiL2LT ��c' ���1 _� �� e✓ r Cm /10 rew . TCz-,P L. GI ,.z Nara `^ 3 L °l CJ 7 �' 6 c Page: 1 40 `7 L 3l / �cG.y. � 43 Yts��C�c l� f'/Z • � Permit: WQ0005763 Owner - Facility: Tuckaseigee Water & Sewer Authority Inspection Date: Inspection Type: Compliance Evaluation Reason for Visit: Routine Inspection Summary: MOucl�S�±�_ 1' PAIUA V A f2 V.0 ,to 0" E 0 Q.zs� `�,,Gkf, o✓ tAt (�. TO L- �-s VTO P t a f-� lam" z� Page: 2 Permit: WQ0005763 Owner -Facility: Tuckaseigee Water & Sewer Authority Inspection Date: Inspection Type: Compliance Evaluation Reason for Visit: Routine Record Keeping Yes No NA NE Is GW monitoring being conducted, if required? 130 IV Cl Are GW samples from all MWs sampled for all required parameters? ❑ ❑ 0 ❑ Are there any GW quality violations? ❑ ❑ 1P ❑ Is GW-59A certification form completed for facility? ❑ ❑ M ❑ Is a copy of current permit on -site? ko ❑ ❑ ❑ Are current metals and nutrient analysis available? ❑ ❑ ❑ Are nutrient and metal loading calculating most limiting parameters? 1444A SAP CAeu.(a�lotJ ❑ ❑ ❑ a. TCLP analysis? WC14 A-10= "� tST QT� • PR CDl2 ❑ ❑ b. SSFA (Standard Soil Fertility Analysis)? (Qf S/4Z- Pei-- �'`�err� ❑ ❑ JP ❑ Are PAN balances being maintained? ILL, V/J,� -0 ❑ ❑ 23 ❑ Are PAN balances within permit limits? M0,A, `141 i + � d+� ❑ ❑ t ❑ Has land application equipment been calibrated? nno�e •ki�.A� 31c1 D7� — `� AND ❑ ❑ rM ❑ ' 1 r +- - { ❑ ❑ IYYIII ❑ Are there pH records for alkaline stabilization? I Sri -{-(-t•, GAS QIa1}��� �a Wlon�-('1,-°^�' Are there pH records for the land application site? a n i~ra� � �w+ ❑ lcl ❑ (P ❑ Are nutrient/crop removal practices in place? ���a r` e� w'1t °jL� -ju- 7 ❑ ❑ Do lab sheets support data reported on Residual Analysis Summary? N 0 XA5 ' r '1" ❑ ❑ ❑ Are hauling records available? ?A^k4- 4 4,^� P�f"`+'� � a -. �. o�� ,�� 10 ❑ ❑ ❑ Are hauling records maintained and up-to-date? UP" 5a ❑ ❑ ❑ # Has permittee been free of public complaints in last 12 months? 70000 Has application occurred during Seasonal Restriction window? ❑ ❑ (P ❑ Comment: Pathogen and Vector Attraction Yes No NA NE a. Fecal coliform SM 9221 E (Class A or B) ys� Q - 2at� b+�t 0 ®1' `� mod' 50 ❑ ❑ ❑ Class A, all test must be <1000 MPN/dry gram Q Geometric mean of 7 samples per monitoring period for class B<2.0"10E6 CFU/dry gram ❑ Fecal coliform SM 9222 D (Class B only) ❑ ❑ ❑ Geometric mean of 7 samples per monitoring period for class B<2.0*10E6 CFU/dry gram ❑ b. pH records for alkaline stabilization (Class A) ❑ ❑ m '+�F}' ❑ C. pH records for alkaline stabilization (Class B) ❑ ❑ Ri ❑ Page: 3 Permit: WQ0005763 Owner -Facility: Tuckaseigee Water & Sewer Authority Inspection Date: Inspection Type: Compliance Evaluation Reason for Visit: Routine Temperature corrected d. Salmonella (Class A, all test must be < 3MPN/4 gram day) e. Time/Temp on: Digester (MCRT) Compost Class A lime stabilization f. Volatile Solids Calculations g. Bench -top Aerobic/Anaerobic digestion results Comment: Treatment Check all that apply Aerobic Digestion Anaerobic Digestion Alkaline Pasteurization (Class A) Alkaline Stabilization (Class B) Compost Drying Beds Other Comment: 't�nA� O W Dr er ■ ■ ME n U[ Page: 4 Alternative 5 - Process To Further Reduce Pathogens PFRP Composting • Were the within -vessel method or static aerated pile methods used? Was the residuals temperature maintained at 55°C (131T) or higher for three consecutive days or longer in the within -vessel method or static aerated pile method? OR • Was the windrow composting method. used? Was the residuals temperature maintained at 550C or higher for 15 consecutive days or longer in the windrow method, and the windrow turned a minimum of five times during this time? Pvlt iIg • Was the residuals dried by direct or indirect with hot gases and moisture content of residuals reduced to 10% or lower? • Did the temperature of the residuals or the of the wet bulb temperature of the gas in contact with the residuals as they leave the dryer exceed 80°C (176T)? PFRP Heat Treatment • Were the residuals liquid during treatment? • Were the residuals heated to a temperature of 180°C (356°F) or higher, for 30 minutes? PFRP Thermophilic Aerobic Digestion • Were the residuals liquid -'during treatment? • Was it an aerobic process with agitation? • Was the mean cell residence time 10 consecutive days. at 55°C (131T) to 60°C (140T)? PFRP Beta Ray Irradiation • Were residuals radiated with beta rays at dosages of at least 1.0 megarad at room temperature [approximately 20°C (68°F)]? PFRP Gamma Ray Irradiation • Were residuals radiated with gamma rays from certain isotopes, such as Cobalt 60 and Cesium 137; at dosages of at least 1.0 megarad at room temperature [approximately 20°C (68°F)]? PFRP Pasteurization . • Was the temperature of the residuals maintained at 70°C (158T) for 30 minutes or longer? L TVVSA.. DRYER..OPERATEONS DAILY RECORD DATE .:START STOP TOTAL RUFA TIME, HRS a -- 1st Dryer Batch Fill Cycle Started e '` Dn+ Cucie Started D&sce�arge Gyc{e Starter p ` 1� Time P itSUfia� cue Exhaust Dis(i lai ge Product i i Y Timer Chamber, in Chamber Ott o�Ur in � :oiUr �'OUt Operator ;N 1p AJ3. en 3i-d Dryer Batch Fill Cycle Started@ TVVSA FRYER -GPER) ;TIONS DAILY RECORD Dry Cycle. Started @ TPmmPraturPs Discharge Cycle Started @ Time Discharge Exnaust I Discharge. Product Dry Timer Chamber In Chamber (JUT Rotor in I Rotor. . Out Operator f I i_ . Repot:�tOG325: Grower: Tuchasel ee Wate NCDAI�C$ Agronomic Division Phone: (919)733-2655 Web site vvww.ne�gr.gov/agronomi/ ;:. � t: & Sewer . Copses to: g 1246 \Vest Main St Cµ�t,ttll'URF,.,,In _ y, �G Sylva, NC 28779 , C - , G Waste nlvszs sport Fa�7�?: Received: 03/26/2012 Completed: 04/12/2012 Links to Helpful Information Jackson County Sample Information Laboratory Results .' ar per milli unless otherwise noted) S Fe Dfrr Zaa . Cu B A10 Cl C P K Ca Afg 391228 sample ID: 3 843 35.0 61.7 '1'WSAI . '� ��� G6o0 17216 4141 7807 3019 5217 9085 59 , IN-N Waste Code: -N119 At Se Li pH SS ON DM% CCB% . AL9(tons) KWO -NO3 Na Ni Cd Pb Description: OR-N 607 8.02 1.84 12.3 5.s5 40 5.s7 93.27 . l0.00 9.70 Alunici at (other) Ur Other Elements lbs/ton wet basis Nutrients Available for First Cro lbs/lost wet basis) Reeoinmendlations: S Pe Mn Zvi Cra B Afo Cd Na Ni Cd Pb Al Se Li • Applicatiori Afetbod N P205 K20 Ca Mg 1.1 0.'01 T . 0.02 Broadcast 37.3 44.1 7.4 8,7 3.4 5.8 . 10.2 o.29 . 0.94 0.39 0.07 1.1 4.01 • T 0.02 Soillncorp 49. 55.2 8.3 10.9 4.2 7.3 12.7 0.36 1.2 0,49 0.09 The waste product contat s large amo Is of nitrogen and zinc. Application rates should be based on crop nitrogen requirement unless zinc is accumulating to excess levels in the soil. _ Completed: A ril 10, 2012 These residuals were prepared by: Tuckaseigee Water and Sewer Authority T otal Amo unt of residual in this load Ton : 1871 North River Rd. Received By, Name: Sylva NC 28779 NC Pion -Discharge Permit # WQ 0005763 Address: Phone Num: Application of these residuals to the land is prohibited except in accordance with the Utilization Agreement.(on back cover) This material shall be prevented from entering any public or private water supply source (including wells) and any stream, lake, or river. ' These residuals should be applied at agronomic rates. Soil tests are recommended. Nort h Carolina Reprogramming of the laboratory -information -management system that makes this report possible is being funded through a grant from the North Carolina Tobacco Trust.Fund Commission. NONE K. ' .at��i '•• ��`':'� • Thank you for using agronomic services to ntnuage nutrients and safeguard enviroitntental quality. Steve Troxler, Commissioner of Agriculture tobacco Iritst Fund Collimission Utilization Agreement (a) By agreeing to accept the bulk class A residuals it is recognized that the application of Class A residuals is allowed under the conditions of this agreement. The application of these Class A residuals is considered the beneficial reuse of a waste under 15A NCAC 02T.1100. The application of these Class A Residuals to the land has been deemed permitted under 15A NCAC.1103 (4) provided the conditions of this agreement are met. Any action resulting in the damages to surface waters or groundwater caused by failure to follow the conditions of the agreement is subject to enforcement action by the division. (b) The person or entity accepting the Class A residuals shall to the best of their knowledge meet the following application requirements: I. Application of the bulk residuals will stop if it becomes known that the application adversely affects.a threatened or endangered species listed cinder - section 4 of the EEndangered Species Act. 11. Application of the bulk residuals shall not occur when the land is flooded, frozen, -or snow-covered or is otherwise in a condition such that runoff of the • residuals would occur. in. Application of the bulk residuals shall not occur within the 100 year ilood elevation unless the bulk residuals are injected or incorporated within a 24- hour period following the residuals land application event. Flood elevation information is available at http://www.ncfloodm4ps.com/default swf.asp IV. Application of the bulk residuals shall not occur during a measurable precipitation event (i.e. > .01" per hour) or within 24'hours following a rainfall event of 0.5 inches or greater in a 24 hour period. V. Residuals stockpiled for more than 14 days shall be covered. VI. - Application of bulk residuals shall not occur if the vertical separation between the seasonal high water table and the bulk residuals is less than one foot. VIL Application of bulk residuals shall not occur if the vertical separation of the . depth to bedrock and the depth of residuals application is less than one foot. VIII. Applicationof bulk residuals shall not occur within 100 feet of a public or private water supply source. IX. Application of bulk residuals shall not occur within 100 feet of any well with the exception of monitoring wells. X. Application of bulk residuals shall not occur within 25 feet of surface waters Signed: for for Tuckaseigee Water and'Sewer Auth. Recipient i Date: N lalytical Services, Inc. 205 Aeadow Road -Suite A aCeAnalyteal Eden, NC 27288 www.pacelabscom f (336)623-8921 Pace Analytical Se Inc. 2225 R le Dr. Asheville, NC 28804 (828)254-7176 Pace Analytical Services, Inc. 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 a ANALYTICAL RESULTS Project: Lime Residual 2/14 Pace Project No.: 92112290 Sample: TWSA DRIED RESIDUAL Lab ID: 92112290001 Collected: 02/14/12 12:00 Received: 02/16/12 11:36 Matrix: Solid Results reported on a "dry -weight" basis Parameters Results Units Report Limit DF Prepared Analyzed CAS No. Qual 6010 MET ICP Analytical Method: EPA 6010 Preparation Method: EPA 3050 Aluminum 19600 mg/kg,t ` 145 20 02/17/12 13:25 02/20/12 18:57 7429-90-5 Arsenic 1.1 mg/kg v 0.38 1 02/17/12 13:25 02/18/12 17:45 7440-38-2 Cadmium 1.9 mg/kg ✓ 0.073. 1 02/17/12 13:25 02/1811217:45 7440-43-9 Calcium 7990 mg/kg 145 20 02/17/12 13:25 02/20/12 18:57 7440-70-2 Chromium 25.8 mg/kg 0.36 1 02/17/12 13:25 02/18/12 17:45 7440-47-3 Copper 330 mg/kg ✓ 0.36 1 02/17/12 13:25 02/18/12 17:45 7440-50-8 Lead 13.8 mg/kg L l 0.36 1 02/17/12 13:25 02/18/12 17:45 7439-92-1 Magnesium 2970 mg/kg 7.3 1 02/17/12 13:25 02/18/12 17:45 7439-95-4 Molybdenum 4.2 mg/kg ✓ 0.36 1 02/17/12 13:25 02/18/12 17:45 7439-98-7 Nickel 10.2 mg/kg ✓ 0.36 1 02/17/12 13:25 02/18/12 17:45 7440-02-0 Potassium 7090 mg/kg 363 1 02/17/12 13:25 02/18/12 17:45 7440-09-7 Selenium 5.2 mg/kg ✓ 0.73 1 02/17/12 13:25 02/18/12 17:45 7782-49-2 Sodium 1000 mg/kg 363 1 02/17/12 13:25 02/18/12 17:45 7440-23-5 Zinc 898 mg/kg ✓ 14.5 20 02/17/12 13:25 02/20/12 18:57 7440-66-6 7471 Mercury Analytical Method: EPA 7471 Preparation Method: EPA 7471 ' Mercury 0.11 mg/kg ✓ 0.0043 1 02/20/12 16:00 02/21/12 12:33 7439-97-6 ''cent Moisture Analytical Method: ASTM D2974-87 Percent Moisture 2.9 % 0.10 1 02/20/12 16:37 9045 pH Soil Analytical Method: EPA 9045 pH at 25 Degrees C 5.5 Std. Units 0.10 1 02/24/12 16:00 Plant Available Nitrogen Analytical Method: 40CFR PART 432.2 Plant Available Nitrogen 2210 mg/kg 1.0 1 02/29/12 12:26 Votal�Vi_frsagen-Calc4lation Anal ti etttod: OG R ART 432 �Ntrogen� t6S rrci /k 40.0 1 02/28/1216:43 7727-37-9 350.1 Ammonia Analytical Method: EPA 350.1 Nitrogen, Ammonia 1020 mg/kg 10.7 1 02/28/12 15:17 7664-41-7 351.2 Total Kjeldahl Nitrogen Analytical Method: EPA 351.2 Nitrogen, Kjeldahl, Total 6680 mg/kg 240 10 02/26/12 13:14 7727-37-9 353.2 Nitrogen, NO2/NO3 Analytical Method: EPA 353.2 Nitrogen, Nitrate ND mg/kg 2.0 1 02/21/12 18:57 Nitrogen, Nitrite ND mg/kg 1.0 1 02/21/12 18:57 Nitrogen, NO2 plus NO3 ND mg/kg 2.0 1 02/21/12 18:57 365.1 Phosphorus, Total Analytical Method: EPA 365.1 Phosphorus 21600 mg/kg 589 200 02/27/1217:52 7723-14-0 f5ate: 02/29/2012 12:26 PM REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.. N2 Page 4 of 15 Utilization Agreement (a) By agreeing to accept the bulk class A residuals it is recognized that the application of Class A residuals is allowed under the conditions of this agreement. The application of these Class A residuals is considered the beneficial reuse of a waste under 15A NCAC 02T.1100. The application of these Class A Residuals to the land has been deemed permitted under 15A NCAC.1103 (4) provided the conditions of this agreement are met. Any action resulting in the damages to surface waters or groundwater caused by failure to follow the conditions of the agreement is subject to enforcement action by the division. (b) The person or entity accepting the Class A residuals shall to the best of their knowledge meet the following application requirements: I. Application of the bulk residuals will stop if it becomes known that the application adversely affects a threatened or endangered species listed under section 4 of the Endangered Species Act. II. Application of the bulk residuals shall not occur when the land is flooded, frozen, or snow-covered or is otherwise in a condition such that runoff of the residuals would occur. III. Application of the bulk residuals shall not occur within the 100 year flood elevation unless the bulk residuals are injected or incorporated within a 24- hour period following the residuals land application event. Flood elevation information is available at http://www.ncfloodmaps.com/default swf.asp IV. Application of the bulk residuals shall not occur during a measurable precipitation event (i.e. > .0 P per hour) or within 24 hours following a rainfall event of 0.5 inches or greater in a 24 hour period. V. Residuals stockpiled for more than 14 days shall be covered. VI. Application of bulk residuals shall not occur if the vertical separation between the seasonal high water table and the bulk residuals is less than one foot. VII. Application of bulk residuals shall not occur if the vertical separation of the depth to bedrock and the depth of residuals application is less than one foot. VIII. Application of bulk residuals shall not occur within 100 feet of a public or private water supply source. IX. Application of bulk residuals shall not occur within 100 feet of any well with the exception of monitoring wells. X. Application of bulk residuals shall not occur within 25 feet of surface waters Signed: for Tuckaseigee Water and Sewer Auth. Recipient Date: Price, Bev From: Price, Bev Sent: Monday, May 23, 2011 4:30 PM To: 'sbrysontwsa@frontier.com' Subject: 2010 Annual Report Certification Forms Stan, You need to fill out the Distribution Of Residual Solids Certification Form that we discussed during the inspection. The Form can be found on our web -site http://portal.ncdenr.org/web/wq/aps/lau/reporting Go to Land Application, Reporting Forms, Residuals, For Permits issued after September 1, 2006, Form DMSDF. Let me know if you have any questions. Inspection question update: It sounds like it would depend on the contract between you and the hauler. Under the current scenario, the responsibility would probably fall on the hauler as they are accepting responsibility for the residuals after it leaves the plant. And when you start distributing under your renewed permit, you will have a utilization agreement that will be signed by the person agreeing to accept and distribute the residuals. The permit does say that the utilization agreement shall be signed by the permittee and the person responsible for application. That person should be responsible for applying residuals at agronomic rates. The permit also says the generator shall provide information on the proper use of the residuals including recommended application rates. The applicator also has to provide all third parties receiving bulk residuals with documentation specifying that application shall occur consistent with the agreement. So it sounds like it will be the responsibility of the person signing the agreement. But, I suppose this interpretation could be argued differently in court. I will help you as much as I can when you put your utilization agreement together. Bev Bev Price - Bev.Price@ncdenr.gov North Carolina Dept. of Environment and Natural Resources Asheville Regional Office Division of Water Quality - Aquifer Protection Section 2090 U.S. 70 Highway Swannanoa, NC 28778 Tel: 828-296-4500 Fax: 828-299-7043 Notice: E-mail correspondence to and from this address may be subject to the North Carolina Public Records Law and may be disclosed to third parties. ILE _Aja C NCD NR North Carolina Department of Environment and Natural Resources Division of Water Quality Beverly Eaves Perdue Coleen H. Sullins Dee Freeman Governor Director Secretary May 23, 2011 Joe Cline Tuckaseigee Water & Sewer Authority 1246 W. Main Street Sylva, NC 28779 SUBJECT: May 17, 2011 Compliance Evaluation Inspection Tuckaseigee Water & Sewer Authority TWSA Class A EQ Residuals Production Facility and Distribution Program Permit No: WQ0005763 Jackson County Dear Mr. Cline: Enclosed please find a copy of the Compliance Evaluation Inspection form from the inspection conducted on May 17, 2011. The facility was found to be in Compliance with permit WQ0005763. As you know, your permit was renewed October 8, 2010. The renewed permit includes the "2T" Rules as referenced in the cover page. Three issues that were noted during the inspection relating to the new permit include: 1) Permit Condition 111.3. - Operation & Maintenance Plan. 2) Permit Condition 111.4. — Utilization Agreement; both of these documents will need to be generated. 3) Bulk residuals are defined as quantities greater than 1.02 short tons or one metric ton. The plant upgrades do not include a set of scales. Please keep in mind that a method for determining weight of residuals distributed will be needed as several permit conditions are dependent upon whether a distribution is considered a "bulk" distribution. Please refer to the enclosed inspection report for additional observations and comments. The assistance of Mr. Stan Bryson was greatly appreciated during the inspection. If you or your staff has any questions, please call me at (828) 296-4685. Sincerely, Beverly rice Environmental Specialist Enclosure cc: Stan Bryson, Wastewater Operations. Superintendent w/enclosure APS Central Files s e -1-11e Fil AQUIFER PROTECTION SECTION —Asheville Regional Office (ARO) 2090 U.S. 70 Highway, Swannanoa, NC 28778-8211 Phone: 828-29BA500 l FAX: 828-299-7043 Customer Service:1-877-623-6748 Internet: www.ncwaterouality.orq An Equal opportunity 1 Affirmative Action Employer Nne orthCarolina AmIrallY Compliance Inspection Report Permit: WQ0005763 Effective: 10/08/10 Expiration: 07/31/14 Owner: Tuckaseigee Water & Sewer Authority SOC: Effective: Expiration: Facility: TWSA Class A EQ Residuals Production Facility and Distribution Program County: Jackson 1871 N River Rd Region: Asheville Sylva NC 28779 Contact Person: Joe Cline Title: Executive Director Phone: 828-586-5189 Directions to Facility: From the intersection of North River Road (SR 1359) and Hwy. 441 in Dillsboro, turn left onto SR 1359. Travel approximately 2 miles to TWSA Plant #1 on the left. System Classifications: Primary ORC: Certification: Phone: Secondary ORC(s): On -Site Representative(s): 24 hour contact name On -site representative Related Permits: Inspection Date: 05/17/2011 Primary Inspector: Beverly Price Secondary Inspector(s): Stan D Bryson Stan D Bryson Entry Time: 10:00 AM Reason for Inspection: Routine Permit Inspection Type: Distribution of Residual Solids (503) Facility Status: ■ Compliant ❑ Not Compliant Question Areas: 0 Miscellaneous Questions 0 Record Keeping (See attachment summary) Exit Time: 11:30 AM Phone: 828-586-5189 Phone: 828-586-5189 Phone: 828-296-4500 Inspection Type: Compliance Evaluation Treatment Page: 1 Permit: WQ0005763 Owner - Facility: Tuckaseigee Water & Sewer Authority Inspection Date: 05/17/2011 Inspection Type: Compliance Evaluation Reason for Visit: Routine Inspection Summary: All sludge was pressed and landfilled in 2010 due to the ongoing renovations of the WWTP. The facility expects to continue to landfill sludge until approximately October of this year when the sludge dryer will come on-line. The permit was renewed 10/8/2010 and includes the new 2T requirements. The facility will need to generate and maintain an Operation & Maintenance Plan (Permit Condition 111.3.) as well as a Utilization Agreement (Permit Condition Ili.4.) Page: 2 Permit: WQ0005163 Owner - Facility: Tuckaseigee Water & Sewer Authority Inspection Date: 05/17/2011 Inspection Type: Compliance Evaluation Reason for Visit: Routine Type Yes No NA NE Land Application ❑ Distribution and Marketing ■ Record Keeping res No NA Nt Is GW monitoring being conducted, if required? ❑ ❑ E Q Are GW samples from all MWs sampled for all required parameters? ❑ ❑ ■ ❑ Are there any GW quality violations? ❑ ❑ ■ '❑ Is GW 59A certification form completed for facility? ❑ ❑ 0 ❑ Is a copy of current permit on -site? ❑ ❑ ❑ Are current metals and nutrient analysis available? ❑ ❑ ■ ❑ Are nutrient and metal loading calculating most limiting parameters? ❑ ❑ ■ ❑ a. TCLP analysis? ❑ ❑ 0 ❑ b. SSFA (Standard Soil Fertility Analysis)? ❑ ❑ 0 ❑ Are PAN balances being maintained? ❑ ❑ ■ ❑ Are PAN balances within permit limits? ❑ ❑ E ❑ Has land application equipment been calibrated? ❑ ❑ 0 ❑ Are there pH records for alkaline stabilization? ❑ ❑ 0 ❑ Are there pH records for the land application site? ❑ ❑ ■ ❑ Are nutrient/crop removal practices in place? ❑ ❑ E ❑ Do lab sheets support data reported on Residual Analysis Summary? ❑ ❑ 0 ❑ Are hauling records available? N ❑ ❑ ❑ Are hauling records maintained and up-to-date? ■ ❑ 0 ❑ # Has permittee been free of public complaints in last 12 months? ■ ❑ ❑ ❑ Has application occurred during Seasonal Restriction window? ❑ ❑ 0 ❑ Comment: Treatment Yes No NA NE Check all that apply Aerobic Digestion Anaerobic Digestion ❑ Alkaline Pasteurization (Class A) ❑ Page: 3 Permit: WQ0005763 Owner - Facility: Tuckaseigee Water & Sewer Authority Inspection Date: 05/17/2011 Inspection Type: Compliance Evaluation Reason for Visit: Routine Alkaline Stabilization (Class B) 0 Compost 0 Drying Beds Q Other M Comment: Fenton Dryer will be installed as part of the the WWTP renovations. Page: 4 Compliance Inspection Report Permit: WQ0005763 Effective: 10/08/10 Expiration: 07/31/14 Owner: Tuckaseigee Water & Sewer Authority SOC: Effective: Expiration: Facility: TWSA Class A EQ Residuals Production Facility and Distribution Program County: Jackson 1871 N River Rd Region: Asheville Sylva NC 28779 Contact Person: Joe Cline Title: Executive Director Phone: 828-586-5189 Directions to Facility: From the intersection of North River Road (SR 1359) and Hwy. 441 in Dillsboro, turn left onto SR 1359. Travel approximately 2 miles to TWSA Plant #1 on the left. System Classifications: y l� Primary ORC: Certification: Phone: 9 Secondary ORC(s): On -Site Representative(s): 24 hour contact name Stan D Bryson Phone: 828-586-5189 On -site representative Stan D Bryson Phone: 828-586-5189 Related Permits: Inspection Date: 5 I 17111 Entry Time: Exit Time: Primary Inspector: Beverly Price Phone: 828-296-4500 Secondary Inspector(s): Reason for Inspection: Routine Inspection Type: Compliance Evaluation Permit Inspection Type: Distribution of Residual Solids (503) Facility Status: � Compliant Q Not Compliant Question Areas: Miscellaneous Questions Record Keeping Treatment Sampling ■ Pathogen and Vector ✓ Attraction A/ G�1eC,k f C. dru�� S� `��" to DMSDf (See attachment summary) ��� ��3�(1jy,'►S V- S AA A a ,,� j AA,( ere_ l��u,(�d s s �s �c: f f �� t,2 whg, QV Siy,+ 0M-eDv7-,L OVAcl,,.) tO n Page: 1 PC jVcJ25 ,� sp���✓,�� �` �,�(, Woo s Permit: WQ0005763 Owner - Facility: Tuckaseigee Water & Sewer Authority Inspection Date: Inspection Type: Compliance Evaluation Reason for Visit: Routine Inspection Summary: t N Zed OP l j L� Q� 1 v0 i U rl O r r CDSzt.>L Page: 2 Permit: WO0005763 Owner - Facility: Tuckaseigee Water & Sewer Authority Inspection Date: Inspection Type: Compliance Evaluation Reason for Visit: Routine Record Keeping Yes No NA NE Is GW monitoring being conducted, if required? ❑ ❑ lb ❑ Are GW samples from all MWs sampled for all required parameters? ❑ ❑ di ❑ Are there any GW quality violations? ❑ ❑,p ❑ Is GW 59A certification form completed for facility? ❑ ❑ Q ❑ i Is a copy of current permit on -site? Are current metals and nutrient analysis availaable? Are nutrient and metal loading calculating most limiting parameters? a. TCLP analysis? i b. SSFA (Standard Soil Fertility Analysis)? Are PAN balances being maintained? Are PAN balances within permit limits? I Has land application equipment been calibrated? Are there pH records for alkaline stabilization? Are there pH records for the land application site? Are nutrient/crop removal practices in place? Do lab sheets support data reported on Residi ual Analysis Summary? Are hauling records available? Are hauling records maintained and up-to-date? #-Has permittee been free of public complaints in last 12 months? Has application occurred during Seasonal Restriction window? Comment: (' Pathogen and Vector Attraction N I_ I� � VJ a. Fecal coliform SM 9221 E (Class A or B) ,• V ZOl Class A, all test must be <1000 MPN/dry gram Geometric mean of 7 samples per monitoring) period for class B<2.0*10E6 CFU/dry gram Fecal coliform SM 9222 D (Class B only) Geometric mean of 7 samples per monitoring. period for class B<2.0*10E6 CFU/dry gram b. pH records for alkaline stabilization (Class A) c. pH records for alkaline stabilization (Classs B) i ❑❑PLO ❑❑CP0 ❑❑r 0 Yes No NA NE Page: 3 Permit: WQ0005763 Owner - Facility: Tuckaseigee Water & Sewer Authority Inspection Date: Inspection Type: Compliance Evaluation Reason for Visit: Routine Temperature corrected d. Salmonella (Class A, all test must be < 3MPN/4 gram day) e. Time/Temp on: Digester (MCRT) Compost Class A lime stabilization f. Volatile Solids Calculations g. Bench -top Aerobic/Anaerobic digestion results Comment: Check all that apply Aerobic Digestion Anaerobic Digestion Alkaline Pasteurization (Class A) Alkaline Stabilization (Class B) Compost Drying Beds Other , Comment: k;o ,,vj 6t- "'j° fv.) A Sampling Describe sampling: �� 1 Is sampling adequate? Is sampling representative? Comment: YA n n n Cl n nnpin 0000 Page: 4 4 . CDENR North Carolina Department of Environment and Division of Water Quality Beverly Eaves Perdue Coleen H. Sullins Governor Director August 6, 2010 Robert J. Cline - Executive Director Tuckaseigee Water and Sewer Authority 1246 West Main St. Sylva, NC 28779 Subject: Acknowledgement of Application No. WQ0005763 TWSA Class A EQ Residuals Production Facility and Distribution Program Distribution of Residual Solids (503) Jackson Dear Mr. Cline: Dee Fgreeman 07 11 26 i0 SecretaRl Asheville Regional Office Amilfer Protecflon The Aquifer Protection Section of the Division of Water Quality (Division) acknowledges receipt of your permit application and supporting materials on July 19, 2010. This application package has been assigned the number listed above and will be reviewed by Alice Wessner. The reviewer will perform a detailed review and contact you with a request for additional information if necessary. To ensure the maximum efficiency in processing permit applications, the Division requests your assistance in providing a timely and complete response to any additional information requests. , Please be aware that the Division's Regional Office, copied below, must provide recommendations prior to final action by the Division. Please also note at this time, processing permit applications can take as long as 60 - 90 days after receipt of a complete application. If you have any questions, please contact Alice Wessner at 919-715-5208, or via e-mail at alice.wessner@ncdenr.gov. If the reviewer is unavailable, you may leave a message, and they will respond promptly. Also note that the Division has reorganized. To review our new organizational chart, go to http://112o.enr.state.nc.us/documents/dwa omchart.vdf. PLEASE REFER TO THE ABOVE APPLICATION NUMBER WHEN MAKING INQUIRIES ON THIS PROJECT. Sinc ely, for Jon Ris d LAU Supervisor cc: Asheville Regional Office, Aquifer Protection Seciio� — ---- — - Harry B. Buckner, P.E. (McGill Associates, P.A., P.O. Box 2259, Asheville, NC 28802) Permit Application File WQ0005763 AQUIFER PROTECTION SECTION 1636 Mail Service Center, Raleigh, North Carolina 27699-1636 Location: 2728 Capital Boulevard, Raleigh, North Carolina 27604 One Phone: 919-733.3221 \ FAX 1: 919-715-0588 FAX 2: 919-715-6048 \ Customer Service: 1-877-623-6748 IIo�-iharOlina Internet: www.ncwaterquality.org An Equal Opportunity \ Affirmative Action Employer N/&a Compliance Inspection Report Permit: WO0005763 Effective: 08/26/05 Expiration: 07/31/13 Owner: Tuckaseigee Water & Sewer Authority SOC: Effective: Expiration: Facility: TWSA Class A EQ Residuals Production Facility and Distribution Program County: Jackson 1871 N River Rd Region: Asheville 2p� Sylva NC 28779 Contact Person: Joe Cline Title: Executive Director Phone: 828-586-5189 Directions to Facility: From the intersection of North River Road (SR 1359) and Hwy. 441 in Dillsboro, turn left onto SR 1359. Travel approximately 2 miles to TWSA Plant #1 on the left. System Classifications: Primary ORC: Certification: Phone: Secondary ORC(s): On -Site Representative(s): 24 hour contact name On -site representative Related Permits: Inspection Date: 05/06/2010 Primary Inspector: Beverly Price Secondary Inspector(s): Stan D Bryson Stan D Bryson Entry Time: 10:00 AM Exit Time: 11:00 AM Phone:828-586-5189 X Phone: 828-586-5189 Phone: 828-296-4500 Reason for Inspection: Routine Inspection Type: Compliance Evaluation Permit Inspection Type: Distribution of Residual Solids (503) Facility Status: Q Compliant O Not Compliant Question Areas: Miscellaneous Questions N Record Keeping Treatment Sampling ■ Pathogen and Vector Attraction t fell 5L11/¢ (See attachment summary) �c� Ja`1• oQ® havi btt,-) G,awIdn cl49 s j %bradt,C,/ !-VLt bow►"I' �wI'�C.�P@��-dA i ✓VLa[.��V� �✓Ic� �il�S� 7 r ►�s �of / W-/ e 7,� Gvcv� Od uPv / - Od. � Yf}� ULe� Ste'✓//C �,�_ S ac.1/J^-` ••� -��i� � Page: 1 r5 rT �i o w ✓ / V_ W1 Ail Permit: WQ0005763 Owner - Facility: Tuckaseigee Water & Sewer Authority Inspection Date: 05/06/2010 Inspection Type: Compliance Evaluation Inspection Summary: p, 0 d kt4 4c, 1� c,0sy Reason for Visit: Routine Page: 2 Permit: WO0005763 Owner - Facility: Tuckaseigee Water & Sewer Authority Inspection Date: 05/06/2010 Inspection Type: Compliance Evaluation Reason for Visit: Routine Record Keeping Yes No NA NE Is GW monitoring being conducted, if required? n ❑ Ix n Are GW samples from all MWs sampled for all required parameters? n n rA ❑ Are there any GW quality violations? ❑ ❑ 5D ❑ Is GW-59A certification form completed for facility? n ❑ [A C1 Is a copy of current permit on -site? ❑ ❑ ❑ Are current metals and nutrient analysis available? j Lrom (Del ❑ ❑ n Are nutrient and metal loading calculating most limiting parameters? ID n n ❑ a. TCLP analysis? MT ❑ n ❑ b. SSFA (Standard Soil Fertility Analysis)? ❑ ❑ ❑ Are PAN balances being maintained? n n n Are PAN balances within permit limits? n❑ ❑ Has land application equipment been calibrated? ❑ ❑ n Are there pH records for alkaline stabilization? 0 n Q 11 Are there pH records for the land application site? n ❑ n Are nutrient/crop removal practices in place? ❑ n Do lab sheets support data reported on Residual Analysis Summary? CtAl `� A R off (❑ ❑ ❑ Are hauling records available? Sam e_ $ I'd ��A � � � 2 � � � �� � 1 �] ❑ n n �.b►��, C��a � nnn Are hauling records maintained and up-to-date? # Has permittee been free of public complaints in last 12 months? n n n Has application occurred during Seasonal Restriction window? ❑ 14 ❑ Comment: Pathogen and Vector Attraction Yes No NA NE a. Fecal coliform SM 9221 E (Class A or B) ❑ n n Class A, all test must be <1000 MPN/dry gram I Ic�l ( S&w.plk VOa 1 zest 6(11 o kold Geometric mean of 7 samples per monitoring period for class B<2.0'10E6 CFU/dry gram ❑ Fecal coliform SM 9222 D (Class B only) ❑❑00 ":�A vwfo_s Geometric mean of 7 samples per monitoring period for class B<2.0`10E6 CFU/dry gram 1 b. pH records for alkaline stabilization (Class A) c. pH records for alkaline stabilization (Class B) ❑ ❑ U ❑ aV,a�Sg '- ekjvk Ckh At& Page:3 J Permit: WQ0005763 Owner - Facility: Tuckaseigee Water & Sewer Authority Inspection Date: 05/06/2010 Inspection Type: Compliance Evaluation Reason for Visit: Routine Temperature corrected d. Salmonella (Class A, all test must be < 3MPN/4 gram day) n n C8 n e. Time/Temp on: El Digester (MCRT) n Compost Class A lime stabilization f. Volatile Solids Calculations n n n g. Bench -top Aerobic/Anaerobic digestion results 0 n ca Cl Comment: Treatment Yes No NA NE Check all that apply Aerobic Digestion 99 Anaerobic Digestion ri Alkaline Pasteurization (Class A) Alkaline Stabilization (Class B) n Compost — Drying Beds ri Other 171 Comment: Sampling Yes No NA NE • I o �.2 c.�t s'�"' 0 - Z O ��� CO �� czS 0n c � � SS-�' Ufi 1" Describe sampling: � 3 C ( _ �4�c��"" i {fib' 1/'�! P nnn t,-S10, r Is sampling adequate?re — cllrS4 Is sampling representative? P; (e Comment: a f o oJ'i �d j c.L — ti 6 " 3 c� VL_Z.,( AJS Page: 4 a f4 jk% a� HCDEHR North Carolina Department of Environment and Natural Resources Division of Water Qu Beverly Eaves Perdue Coleen H. Sullins Governor Director November 24, 2009 CERTIFIED MAIL RETURN RECEIPT REQUESTED ROBERT J. CLINE TUCKASEIGEE WATER & SEWER AUTHORITY 1246 WEST MAIN STREET SYLVA, NORTH CAROLINA 28779 Dear Mr. Cline: Freeman Secretary BET 0 HU r,4Ci;;;f@��!! t'O'r tifl11 Subj ect: Return of Permit Application Package WQ0005763 TWSA Class A Residuals Production & Distribution Facility Distribution of Residuals Jackson County This letter is in reference to your permit modification request . received on November 5, 2009. The application is being returned because it is incomplete due to the reason outlined below. The submitted application fee of $245 is also enclosed. Please address the following issue: 1. In addition to the Form DRS 070807 that you submitted, a completed FORM RSCA (Residuals Source Certification Attachment) is also required. Form RSCA is required for all application packages and should include all supporting documentation as applicable (see Instruction G on Form DRS 070807). Form RSCA can be downloaded at: litt-o://h2o.enr.state.nc.us/lau/applications.html. When you have obtained the required information that is needed to make your application package complete, you may submit a new application package and appropriate permit processing fee. Also, please note that Application Instruction D on Form DRS 070807 requires that plans and specification be submitted only for items pertinent to the residuals treatment and storage units. Please do not re -submit the comprehensive plans and specifications for the entire treatment facility. AQUIFER PROTECTION SECTION 1636 Mail Service Center, Raleigh, North Carolina 27699=1636 Location: 2728 Capital Boulevard, Raleigh, North Carolina 27604 Phone: 919-733-3221 1 FAX 1: 919-715-0588; FAX 2: 919-715-60481 Customer Service: 1-877-623-6748 Internet: www.ncwateroualiW.org Of iCa.1"0l..ina An Equal Opportunity \ Affirmative Action Employer Mr. Robert J. Cline November 24, 2009 Page 2 of 2 • If you have questions concerning this matter, feel free to contact me at (919) 715-6187 or lori.montgomery@ncdenr.gov. Sincerely, Lori �ALt ryPE Environmental Engineer cc: David L. Honeycutt, PE — McGill Associates, PO Box 2259, Asheville, NC 28802 �Ajshe i44e'�R nal�f��c'�Ar�a e'i'��o Sew Zo'' n'�► LAU Files - Returns a, 1 North Carolina Depart May 15, 2009 Joe Cline, Executive Director Tuckaseigee Water & Sewer Authority Post Office Box 1051 Sylva, NC 28779 Michael F. Easley, Governor William G. Ross Jr., Secretary if Environment and Natural Resources Coleen H. Sullins, Director Division of Water Quality Asheville Regional Office SUBJECT: May 4, 2009 Compliance Evaluation Inspection Tuckaseigee Water & Sewer Authority TWSA Class A EQ Residuals Production Facility and Distribution Program Distribution of Residual Solids (503) Permit No: WQ0005763 Jackson County Dear Mr. Cline: Enclosed please find a copy of the Compliance Evaluation Inspection form from the inspection that I conducted on May 4, 2009. The facility was found to be in Compliance with permit WQ0005763. Please refer to the enclosed inspection report (inspection Summary Page 2) for additional observations and comments. If you or your staff has any questions, please call me at (828) 296-4500. Sincerely, W E Williams Environmental Specialist Enclosure cc: Stan Bryson, ORC APS Central Files �,sh' e itle F-Yul"" d NorthCarolin Natwully North Carolina Division of Water Quality — Asheville Regional Office 2090 U.S. Highway 70 Swannanoa, NC 28778 Phone (828) 296-4500 Aquifer Protection Section FAX (828) 299-7043 Customer Service 1-877-623-6748 Internet: h2o.enr.state.nc.us An Equal Opportunity/Affirmative Action Employer— 50% Recycledl10% Post Consumer Paper Compliance Inspection Report Permit: WQ0005763 Effective: 08/26/05 Expiration: 07/31/10 Owner: Tuckaseigee Water & Sewer Authority SOC: Effective: Expiration: Facility- TWSA Class A EQ Residuals Production Facility and Distribution Program County: Jackson 1871 N River Rd Region: Asheville Sylva NC 28779 Contact Person: Joe Cline Title: Executive Director Phone: 828-586-5189 Directions to Facility: From the intersection of North River Road (SR 1359) and Hwy. 441 in Dillsboro, turn left onto SR 1359. Travel approximately 2 miles to TWSA Plant#1 on the left. System Classifications: Primary ORC: Certification: Phone: Secondary ORC(s): On -Site Representative(s): Related Permits: Inspection Date: 05/04/2009 Entry Time: 10:30 AM Exit Time: 11:30 AM Primary Inspector: Edward M Williams Secondary Inspector(s): Reason for Inspection: Routine Permit Inspection Type: Distribution of Residual Solids (503) Facility Status: ® Compliant Q Not Compliant Question Areas: IN Miscellaneous Questions ® Record Keeping IS Pathogen and Vector ® Storage Attraction (See attachment summary) Phone: Inspection Type: Compliance Evaluation ® Treatment ® Sampling Page: 1 Permit: WQ0005763 Owner - Facility: Tuckaseigee Water & Sewer Authority Inspection Date: 05/04/2009 Inspection Type: Compliance Evaluation Reason for Visit: Routine Inspection Summary: The inspection consisted of a records review, tour of the facilities and in-depth review of the 2008 Annual Report. The finished product is stored on an uncovered cement pad and leachate/rainwater drains back to the head of the VWVfP. The facility appeared to be well maintained and the records were in good order. Page: 2 Permit: WQ0005763 Owner - Facility: Tuckaseigee Water & Sewer Authority Inspection Date: 05/04/2009 Inspection Type: Compliance Evaluation Reason for Visit: Routine Type Yes No NA NE Land Application ❑ Distribution and Marketing Record Keeping Yes No NA NE Is GW monitoring being conducted, if required? ❑ ❑ ■ ❑ Are GW samples from all MWs sampled for all required parameters? ❑ ❑ ® ❑ Are there any GW quality violations? ❑ ❑ ■ ❑ Is GW-59A certification form completed for facility? ❑ ❑ ■ ❑ Is a copy of current permit on -site? ■ ❑ ❑ ❑ Are current metals and nutrient analysis available? ■ ❑ ❑ Are nutrient and metal loading calculating most limiting parameters? ®❑ ❑ ❑ a. TCLP analysis? ❑ ❑ Cl b. SSFA (Standard Soil Fertility Analysis)? ❑ ❑ ❑ Are PAN balances being maintained? ❑ ❑ ® ❑ Are PAN balances within permit limits? ❑ ❑ ® ❑ Has land application equipment been calibrated? ❑ ❑ v ❑ Are there pH records for alkaline stabilization? E ❑ ❑ ❑ Are there pH records for the land application site? ❑ ❑ ■ ❑ Are nutrient/crop removal practices in place? ❑ ❑ ® ❑ Do lab sheets support data reported on Residual Analysis Summary? 0 ❑ ❑ ❑ Are hauling records available? ■ ❑ ❑ ❑ Are hauling records maintained and up-to-date? O ❑ ❑ ❑ # Has permittee been free of public complaints in last 12 months? ®❑ ❑ ❑ Has application occurred during Seasonal Restriction window? ❑ ❑ a ❑ Comment: Pathogen and Vector Attraction Yes No NA NE a. Fecal coliform SM 9221 E (Class A or B) ®❑ ❑ ❑ Class A, all test must be <1000 MPN/dry gram 0 Geometric mean of 7 samples per monitoring period for class B<2.0*10E6 CFU/dry gram ❑ Fecal coliform SM 9222 D (Class B only) ❑ ❑ ■ ❑ Page: 3 Permit: WQ0005763 Owner - Facility: Tuckaseigee Water & Sewer Authority Inspection Date: 05/04/2009 Inspection Type: Compliance Evaluation Reason for Visit: Routine Geometric mean of 7 samples per monitoring period for class B<2.0*10E6 CFU/dry gram b. pH records for alkaline stabilization (Class A) ® n n n c. pH records for alkaline stabilization (Class B) n n ® n Temperature corrected n d. Salmonella (Class A, all test must be < 3MPN/4 gram day) n n e. Time/Temp on: in Cl n 0 Digester (MCRT) n Compost n Class A lime stabilization 191 f. Volatile Solids Calculations n n la g. Bench -top Aerobic/Anaerobic digestion results n .n Comment: Treatment Yes No NA NE Check all that apply Aerobic Digestion Anaerobic Digestion n Alkaline Pasteurization (Class A) IN Alkaline Stabilization (Class B) n Compost fl Drying Beds n Other n Comment: Sampling Yes No NA NE Describe sampling: Grab samples are collected from conveyor belt to verify VAR (option 6). Fecal samples are collected once per month and metals and residual samples are collected quarterly from the storage pad. TCLP samples are collected annually. 10-20 grab samples are collected and then composited. Is sampling adequate? ® n n Is sampling representative? ®❑ n Comment: Page: 4 Michael F. Easley, Governor - William G. Ross Jr., Secretary North Carolina Department of Environment and Natural Resources Coleen H. Sullins, Director Division of Water Quality - Aquifer Protection Section August 5, 2008 CERTIFIED MAIL # 7002 0460 0001 9899 5473 RETURN RECEIPT REQUESTED Joe Cline, Director Executive Tuckaseigee Water & Sewer Authority 1246 W. Main Street Sylva, NC 28779 j Subject: 2007 Annual Report Review NOTICE OF VIOLATION (NOV-2.008-PC-0545) Additional Information Request Permit No. WQ0005763 TWSA Class A EQ Residuals Production Facility and Distribution Program Jackson County Dear Mr. Cline: . A review of TWSA' Class A EQ Residuals Production Facility and Distribution Program's Annual Report for 2007 showed the facility did not met the Vector Attraction Reduction (VAR) requirements on three occasions. Option 6 was chosen as the method to verify VAR: The requirements of Option 6 are to raise the pH of the sludge to at least 12, maintain it at 12 for 2 hours without the addition of more alkali. And- maintain a pH of at least 11.5 without addition of ,more alkali for an additional 22 hours. The 24 hour pH measurement was: not documented on 9/7/07 and 11/8/07. The pH was not raised to 12 on 11 /19/07. To prevent further :action, carefully review the violations and deficiencies noted above and respond in writing to this office within fifteen (15) working days of receipt of this letter. You should address the causes of noncompliance and all actions taken to prevent the recurrence of similar situations. North Carolina Division of Water Quality — Asheville Regional Oft -ice 2090 U.S. Highway 70, Swannanoa, NU 28772E Aquifer Protection Section I Phone (828) 296-4500 FAX (828) 299-7043 Customer'Service 1-877-623-6748 .One Carolina �tumily Internet: http:// h2o.enr.state.nc.us An Equal Opportunity/Affirmative Action Empl6yer — 50% Recycled/10% Post Consumer Paper Mr. Cline _ August 5, 2008 Page 2 In addition, the TCLP Analysis was not included in the report. Please submit 3 copies of the TCLP Analysis within fifteen (15) days of receipt of this request. The additional information should be submitted to: - NC DENR Division of Water Quality Aquifer Protection Section Land Application Unit 1636 Mail Service Center Raleigh NC 27699-1636 Attn: Ed Hardee If you should have any questions, please do not hesitate to contact Bev Price at (828) 296-4500. Sincerely, G. Landon Davidson, L.G. Aquifer Protection Regional Supervisor Asheville Regional Office cc: Stan Bryson, WWTP Superintendent APS Central Files APS Enforcement Files ,.Asheville--Region�a'1=Office APS-Files North Carolina Dr 0 0P V AQUIFER PROTECTION Joe Cline, Executive Director Tuckaseigee Water & Sewer Authority J Sylva, NC 28779 Dear Mr. Cline: Enclosed please fin inspection that I conducted with permit WQ0005763. February 5, 2008 Michael F. Easley, Governor William G. Ross Jr., Secretary ant of Environment and Natural Resources Coleen H. Sullins, Director Division of Water Quality Asheville Regional Office SUBJECT: January 31, 2008 Compliance Evaluation Inspection Tuckaseigee Water & Sewer Authority TWSA Class A EQ Residuals Production Facility and Distribution Program Distribution of Residual Solids (503) Permit No: WQ0005763 Jackson County d a copy of the Compliance Evaluation Inspection form from the on January 31, 2008. The facility was found to be in Compliance Please refer to the enclosed inspection report (Inspection Summary Page 2) for additional observations and comments. If you or your staff has any questions, please call me at (828) 296-4500. Sincerely, Beverly Price Environmental Specialist Enclosure cc: Stan Bryson, ORC APS Central Files �'�`APS' Asheville�Files �; NOne hCarolino North Carolina Division of Water Quality —Asheville Regional Office 2090 U.S. Highway 70 Swannanoa, NC 28778 Phone (828) 296-4500 Aquifer Protection Section FAX (828) 299-7043 Customer Service 1-877-623-6748 Internet: h2o.enr.state.nc.us An Equal Opportunity/Affirmative Action Employer —50% Recycled110% Post Consumer Paper Compliance Inspection Report Permit: WQ0005763 Effective: 08/26/05 Expiration: 07/31/10 Owner: Tuckaseigee Water & Sewer Authority SOC: Effective: Expiration: Facility: TWSA Class A EQ Residuals Production Facility and Distribution Program County: Jackson 1871 N River Rd Region: Asheville Sylva NC 28779 Contact Person: Joe Cline Title: Executive Director Phone: 828-586-5189 Directions to Facility: From the intersection of North River Road (SR 1359) and Hwy. 441 in Dillsboro, turn left onto SR 1359. Travel approximately 2 miles to TWSA Plant #1 on the left. System Classifications: Primary ORC: Stan D Bryson Certification: 13180 Phone: 828-586-9318 Secondary ORC(s): On -Site Representative(s): 24 hour contact name On -site representative Related Permits: Inspection Date: 01/31/2008 Primary Inspector: Beverly Price Secondary Inspector(s): Stan D Bryson Stan D Bryson Entry Time: 10:00 AM Reason for Inspection: Routine Permit Inspection Type: Distribution of Residual Solids (503) Facility Status: IN Compliant ❑ Not Compliant Question Areas: Miscellaneous Questions 0 Record Keeping ■ Pathogen and Vector Attraction (See attachment summary) Exit -Time: 11:30 AM Phone: 828-586-9318 Phone; 828-586-9318 Phone: 828-296-4500 Inspection Type: Compliance Evaluation 0 Treatment - ® Sampling Page: 1 Permit: WQ0005763 Owner - Facility: Tuckaseigee Water & Sewer Authority Inspection Date: 01/31/2008 Inspection Type: Compliance Evaluation Reason for Visit: Routine ' Inspection Summary: The inspection consisted of a records review as well as a tour of the facilities. The finished product is stored on a cement pad (not covered). Any leachate from the storage pad drains back to the head of the WWTP. The facility appears to be operating according to permit conditions. Further review of the monitoring data for 2007 will be conducted when the 2007 Annual Report is received in the regional office. Page: 2 Permit: WQ0005763 Owner - Facility: Tuckaseigee Water & Sewer Authority Inspection Date: 01/31/2008 Inspection Type: Compliance Evaluation Reason for Visit: Routine Type. Yes No NA NE Land Application ❑ Distribution and Marketing ■ Record Keeping Yes No NA NE Is GW monitoring being conducted, if required? ❑ ❑ ■ ❑ Are GW samples from all MWs sampled for all required parameters? ❑ ❑ ■ ❑ Are there any GW quality violations? ❑ ❑ ■ ❑ Is GW-59A certification form completed for facility? ❑ ❑ ■ ❑ Is a copy of current permit on -site? ■ ❑ ❑ ❑ Are current metals and nutrient analysis available? ■ ❑ ❑ ❑ Are nutrient and metal loading calculating most limiting parameters? ■ ❑ ❑ ❑ a. TCLP analysis? ■ ❑ ❑ ❑ b. SSFA (Standard Soil Fertility Analysis)? ❑ ❑ ■ ❑ Are PAN balances being maintained? ❑ ❑ ■ ❑ Are PAN balances within permit limits? ❑ ❑ ■ ❑ Has land application equipment been calibrated? ❑ ❑ ■ ❑ Are there pH records for alkaline stabilization? ■ ❑ .0 ❑ Are there pH records for the land application site? ❑ ❑ ■ ❑ Are nutrient/crop removal practices in place? ❑ ❑ ■ ❑ Do lab sheets support data reported on Residual Analysis Summary? ❑ ❑ ■ ❑ Are hauling records available? ■ ❑ ❑ ❑ Are hauling records maintained and up-to-date? ■ ❑ ❑ ❑ # Has permittee been free of public complaints in last 12 months? ■ ❑ ❑ ❑ Has application occurred during Seasonal Restriction window? ❑ ❑ ■ Q Comment: Pathogen and Vector Attraction Yes No NA NE a. Fecal coliform SM 9221 E (Class A or B) ■ ❑ ❑ ❑ Class A, all test must be <1000 MPN/dry gram ■ Geometric mean of 7 samples per monitoring period for class B<2.0`10E6 CFU/dry gram ❑ Fecal coliform SM 9222 D (Class B only) ❑ ❑ ■ ❑ Page: 3 Permit: WQ0005763 Owner - Facility: Tuckaseigee Water & Sewer Authority Inspection Date: 01/31/2008 Inspection Type: Compliance Evaluation Reason for Visit: Routine Geometric mean of 7 samples per monitoring period for class B<2.0"10E6 CFU/dry gram n b. pH records for alkaline stabilization (Class A) ■ n n ❑ c. pH records for alkaline stabilization (Class B) n n • ■ n Temperature corrected n d. Salmonella (Class A, all test must be < 3MPN/4 gram day) n n ■ e. Time/Temp on: ■ Q n n Digester (MCRT) n Compost n Class A lime stabilization ■ f. Volatile Solids Calculations rl n ■ g. Bench -top Aerobic/Anaerobic digestion results n n ■ n Comment: Treatment Yes No NA NE Check all that apply Aerobic Digestion ■ Anaerobic Digestion Alkaline Pasteurization (Class A) ■ Alkaline Stabilization (Class B) Compost ❑ Drying Beds n Other n Comment: Sampling Yes No NA NE Describe sampling: Grab samples are collected frorm the conveyor belt to verify VAR (Option 6). Fecal samples are collected once per month and metals and residuals samples are collected quarterly from the storage pad. TCLP samples are collected annually. 10-20 grab samples are collected and then composited. Is sampling adequate? ■ ❑ ❑ n Is sampling representative? ■ n n ❑ Comment: Page: 4 Compliance Inspection Report Permit: WO0005763 Effective: 08/26/05 Expiration: 07/31 /10 Owner: Tuckaseigee Water & Sewer Authority SOC: Effective: Expiration: Facility: TWSA Class A EQ Residuals Production Facility and Distribution Program County: Jackson 1871 N River Rd Region: Asheville Sylva NC 28779 Contact Person: Joe Cline Dveo�f ©� Title: Phone: Directions to Facility: Tw �S+ From the intersection of North River Road (SR 1359) and Hwy. 441 in Dillsboro, turn left onto SR 1359. Travel approximately 2 miles to TWSA Plant #1 on the left. System Classifications: Primary ORC: Stan D Bryson Certification: 13180 Phone: 828-586-9318 Secondary ORC(s): On -Site Representative(s): 24 hour contact name On -site representative Related Permits: Inspection Date: 01/31/2008 Primary Inspector: Beverly Price Secondary Inspector(s): Stan D Bryson Stan D Bryson - Entry Time: 10:00 AM Reason for Inspection: Routine Permit Inspection Type: Distribution of Residual Solids (503) Facility Status: ❑ Compliant ❑ Not Compliant Question Areas: Miscellaneous Questions E Record Keeping ■ Pathogen and Vector Attraction Exit Time: 11:30 AM Phone: 828-586-9318 Phone: 828-586-9318 Phone: 828-296-4500 Inspection Type: Compliance Evaluation 0 Treatment 0 Sampling (See attachment summary) iu�/ 1 I �Cilf-v0 sLcl tn�o`� 1v�14A �. d, A_ V 0 j, fV\-Av-y C t ru Page: 1 w 2.a v 7 Permit: WQ0005763 Owner - Facility: Tuckaseigee Water & Sewer Authority Inspection Date: 01/31/2008 Inspection Type: Compliance Evaluation Reason for Visit: Routine Inspection Summary: Page: 2 Permit: WO0005763 Owner - Facility: Tuckaseigee Water & Sewer Authority Inspection Date: 01/31/2008 Inspection Type: Compliance Evaluation Reason for Visit: Routine Record Keeping Yes No NA NE Is GW monitoring being conducted, if required? ❑ ❑ M ❑ Are GW samples from all MWs sampled for all required parameters? ❑ ❑ IM ❑ Are there any GW quality violations? ❑ ❑ a ❑ Is GW-59A certification form completed for facility? ❑ ❑ @ ❑ Is a copy of current permit on -site? M ❑ ❑ ❑ Are current metals and nutrient analysis available2f, sewI-fly.ar� 2�d7 10 ❑ ❑ ❑ Are nutrient and metal loading calculating most limiting parameters? U n ❑ ❑ / '1 n lsco ham, . Ge rs©j. j j�i , , J ec a. TCLP analysis. Z 13d� 4I ❑ .❑ ❑ b. SSFA (Standard Soil Fertility Analysis)? h% o-S�"/���`S �d Lr,¢ c� ❑ ❑ '+ ❑ Are PAN balances being maintained? 1 ❑ ❑ a ❑ Are PAN balances within permit limits? ❑ ❑ a ❑ Has land application equipment been calibrated? ❑ ❑ 0 ❑ Are there pH records for alkaline stabilization? U ❑ ❑. ❑ Are there pH records for the land application site? ❑ ❑ 99 ❑ Are nutrient/crop removal practices in place? ❑ ❑ Do lab sheets support data reported on Residual Analysis Summary? ❑ 0 ❑ Are hauling records available? 9 ❑ ❑ ❑ Are hauling records maintained and up-to-date? ❑ ❑ ❑ # Has permittee been free of public complaints in last 12 months? `.@ ❑ ❑ ❑ Has application occurred during Seasonal Restriction window? ❑ ❑ 0 ❑ Comment: Pathogen and Vector Attraction Yes No NA NE a. Fecal coliform SM 9221 E (Class A or B) ❑ ❑ Class A, all test must be <1000 MPN/dry gram Geometric mean of 7 samples per monitoring period for class B<2.0*10E6 CFU/dry gram ❑ Fecal coliform SM 9222 D (Class,B only) ❑ ❑ 0 ❑ Geometric mean of 7 samples per monitoring period for class 13<2.0*10E6 CFU/dry gram ❑ b. pH records for alkaline stabilization (Class A) ❑ ❑ ❑ c. pH records for alkaline stabilization (Class B) ❑ ❑ @ ❑ Page: 3 r Permit: WQ0005763 Owner - Facility: Tuckaseigee Water & Sewer Authority Inspection Date: 01/31/2008 Inspection Type: Compliance Evaluation Reason for Visit: Routine Temperature corrected 11 d. Salmonella (Class A, all test must be < 3MPN/4 gram day) 0 ❑ V ❑ e. Time/Temp on: ME Q ❑ ❑ Digester (MCRT) Q Compost Class A lime stabilization �G:S"� �r �Zc.`�Eo��`� ►a l 1 z�-n�.,�..�.0 � P `� J f. Volatile Solids Calculations g. Bench -top Aerobic/Anaerobic digestion results Comment: Treatment Check all that apply Aerobic Digestion Anaerobic Digestion Alkaline Pasteurization (Class A) Alkaline Stabilization (Class B) Compost Drying Beds Other Comment: 10-1 0 Sampling _ 0 -� Describe sampling: -Fe Is sampling adequate? Is sampling representative? Comment: 0 n a n n 0 'n Yes No NA NE 4l❑n0l 9❑n■ Page: 4 / 2- 3 �cvv- di21'�o�-c�l�•, �5�-16aS3 yn� -7--74 -12 Y v34 S f F 3 ' VA P- PIS }ram 1, 1 oil* leN9 S � �Y'CS b N t > a D 'X ra !" ��, i $ -N h n X KNi'^' Ak //� /J x� \ /�� (•q-yy`�-�J(.C.II +P Pec�-durc: '�;L 67 ��v Cam+• soma- Y14-dc Hc, 4�5- I -C�, a ®-( A4- fah �- -� ���� u �J �Pr4duct- Inewi- zrm�rF �t�,Lur� _(pµ /� 3 TWS C J 76 oz , ,S�U cr� l%%��/'L ,� � Cn G�4.�0�%�f�r"'C ^ �1• �Uc f�S 73,3 — 331Z. Cv,,-, 310,60 evl ��� Cd•-��G��%�-��d-� ASS lC�' cam.. &`'k.-c._UP' ' ,e AJ oArQek4!], y, &0 r r 9,-�W&67V 0,1Y tit '� (� C 4ivti J�x yJA7z� Michael F. Easley, Governor QG William G. Ross Jr., Secretary { North C w'na Department of Environment and Natural Resources (� Alan W. Klimek, P.E. Director N Division of Water Quality ,AQUIFER PROTECTION February 13, 200; Joe Cline, Executive Director Tuckaseigee Water & Sewer Authority Post Office Box 1051 Sylva, NC 28779 SUBJECT: February 7, 2007 Compliance Evaluation Inspection TWSA Class A EQ Residuals Production Facility & Distribution Program Distribution of Residual Solids (503) Permit No: WQ0005763 Jackson County Dear Mr Cline: Enclosed please find a copy of the Compliance Evaluation Inspection form from the inspection that I conducted on February 7, 2007. The facility was found to be in Compliance with permit WQ0005763. The following recommendation is offered regarding the operations log (Lime Stabilization Daily Log) for the Class A facility: the entry time for residuals into the pasteurization vessel is documented; the Daily Log should also document the exit time from the pasteurization vessel. Please refer to .the enclosed inspection report (Inspection Summary Page 2) for additional observations and comments. If you or your staff has any questions, please call me at (828) 296-4500. Sincerely, Beverly Price Environmental Specialist Enclosure c: Stan Bryson, WWTP ORC APS Central Files S= e� 111 el-Fi es No e hCarolina Natum!!y North Carolina Division of Water Quality — Asheville Regional Office 2090 U.S. Highway 70 Swannanoa, NC 28778 Phone (828) 296-4500 Aquifer Protection Section FAX (828) 299-7043 Customer Service 1-877-623-6748 Internet: h2o.enr.state.nc.us An Equal Opportunity/Affirmative Action Employer— 50% Recycledl10% Post Consumer Paper Compliance Inspection Report Permit: WQ0005763 Effective: 08/26/05 Expiration: 07/31/10 Owner: Tuckaseigee Water & Sewer Authority SOC: Effective: Expiration: Facility: TWSA Class A EQ Residuals Production Facility and Distribution Program 1871 County: Jackson N River Rd Region: Asheville Sylva NC 28779 Contact Person: Joe Cline Phone: Directions to Facility: From the intersection of North River Road (SR 1359) and Hwy. 441 in Dillsboro, turn left onto SR 1359. Travel approximately 2 miles to TWSA Plant #1 on the left. Primary ORC: Stan D Bryson Certification: 13180 Phone: 828-586-9318 Secondary ORC(s): On -Site Representative(s): On -site representative Stan D Bryson Phone: 828-586-9318 24 hour contact name Stan D Bryson Phone: 828-586-9318 Related Permits: Inspection Date: 02/07/2007 Entry Time: 10:00 AM Exit Time: 11:30 AM Primary Inspector: Beverly Price Phone: 828-296-4500 Secondary Inspector(s): Reason for Inspection: Routine Inspection Type: Compliance Evaluation Permit Inspection Type: Distribution of Residual Solids (503) Facility Status: ■ Compliant ❑ Not Compliant Question Areas: Miscellaneous Questions Record Keeping Treatment Sampling . Pathogen and Vector Attraction (See attachment summary) Page: 1 Permit: WQ0005763 Owner - Facility: Tuckaseigee Water & Sewer Authority Inspection Date: 02/07/2007 Inspection Type: Compliance Evaluation Reason for Visit: Routine Inspection Summary: The inspection included a records review and tour of the facilities. Further review of the records will be conducted when the 2006 Annual Report is received. Records appeared to be in order and accurate. There were no Class A residuals produced in 2006. All residuals produced in 2006 were sent to RB Landfill in Homer, Ga. Class A residuals were last produced in March 2005, prior to renewal of permit. Renewed permit(August 26, 2005) has TCLP requirements while the old permit did not. Those residuals distributed in 2006 were produced under the old permit requirements. There was no TCLP data for the residuals distributed in 2006. It is recommended that "time out' data be added to the Lime Stabilization Daily Log sheet for Pathogen Reduction Pasturization Temperatures. Page: 2 Permit: WQ0005763 Owner - Facility: Tuckaseigee Water & Sewer Authority Inspection Date: 02/07/2007 Inspection Type: Compliance Evaluation Reason for Visit: Routine TY � Yes No NA NE Land Application fl Distribution and Marketing ■ Record Kee}Din Yes No NA NE Is GW monitoring being conducted, if required? ❑ ❑ ■ ❑ Are GW samples from all MWs sampled for all required parameters? ❑ ❑ ■ ❑ Are there any GW quality violations? ❑ ❑ ■ ❑ Is GW-59A certification form completed'for facility? ❑ ❑ ■' ❑ Is a copy of current permit on -site? ■ ❑ ❑ ❑ Are current metals and .nutrient analysis available? ■ 0 ❑ ❑ Are nutrient and metal loading calculating most limiting parameters? ■ ❑ ❑ ❑ a. TCLP analysis? ❑ ■ ❑ ❑ b. SSFA (Standard Soil Fertility Analysis)? ❑ ❑ ■ ❑ Are PAN balances being maintained? ❑ ❑ ■ ❑ Are PAN balances within permit limits? ❑ ❑ ■ ❑ Has land application equipment been calibrated? ❑ ❑ ■ ❑ Are .there pH records for alkaline stabilization? ❑ ❑ ■ ❑ Are there pH records for the land application site? ❑ ❑ ■ ❑ Are nutrient/crop removal practices in place? ❑ ❑ ■ ❑ Do lab sheets support data reported on Residual Analysis Summary? ■ ❑ ❑ ❑ Are hauling records available? ■ ❑ ❑ ❑ Are hauling records maintained and up-to-date? ■ ❑ ❑ ❑ # Has permittee been free of public complaints in last 12 months? ■ ❑ ❑ ❑ Has application occurred during Seasonal Restriction window? 6 ❑ ❑ ■ ❑ Comment: No TCLP collected for the residuals distributed in 2006 - residuals distributed in 2006 were produced in 2005 under the old permit requirements which did not include TCLP monitoring. Pathogen and Vector Attraction Yes No NA NE a. Fecal coliform SM 9221 E (Class A or B) ■ ❑ ❑ ❑ Class A, all test must be <1000 MPN/dry gram ■ Geometric mean of 7 samples per monitoring period for class B<2.0'10E6 CFU/dry gram ❑ a Page: 3 Permit: WQ0005763 Owner - Facility: Tuckaseigee Water & Sewer Authority Inspection Date: 02/07/2007 Inspection Type: Compliance Evaluation Reason for Visit: Routine n ❑ ■ n Fecal coliform SM 9222 D (Class B only) Geometric mean of 7 samples per monitoring period for class B<2.0*10E6 CFU/dry gram b. pH records for alkaline stabilization (Class A) n n ❑ ❑ Q c. pH records for alkaline stabilization (Class B) Temperature corrected ■ d. Salmonella (Class A, all test must be < 3MPN/4 gram day) 0 0 0 0 e. Time/Temp on: Digester (MCRT) n Compost Class A lime stabilization ■ n n ■ n f. Volatile Solids Calculations Cl■ Cl g. Bench -top Aerobic/Anaerobic digestion results Comment: Yes No NA NE Treatment Check all that apply Aerobic Digestion ■ n Anaerobic Digestion Alkaline Pasteurization (Class A) ■ Alkaline Stabilization (Class: B) n Compost Drying Beds n Other s-' Comment: a Sam Ding Yes No NA NE Describe sampling: Grab samples are collected from conveyor belt and composited for VAR verification (Option 6). Grab samples are composited from the residuals stored on the pad for fecal, metals and TCLP. Is sampling adequate? Is sampling representative? Comment: ■nCln ■nnn Page: 4 Compliance Inspection Report Permit: WQ0005763 Effective: 08/26/05 Expiration: 07/31/10 Owner: Tuckaseigee Water & Sewer Authority SOC: Effective: Expiration: Facility: TWSA Class A EQ Residuals Production Facility and Distribution Program County: Jackson �eal� 1871 N River Rd Snrwl Region: Asheville 219/07 MS - /� / Sylva NC 28779 Contact Person: -J heiwg C0"14_0�((JCA T ZX5v %'I; fsla,,) Phone: 828-586-5189 Directions to Facility: 4,3- 117 /anS %It'd 6 or-. Primary ORC: _54a,\ T�r33xn Certification: L•A Secondary ORC(s): On -Site Representative(s): On -site representative 24 hour contact name Related Permits: Inspection Date: 02/02/2007 Primary Inspector: Beverly Price Secondary Inspector(s): Stan D Bryson Stan D Bryson Entry Time: 10:00 AM Reason for Inspection: Routine Permit Inspection Type: Distribution of Residual Solids (503) Facility Status: ❑ Compliant ❑ Not Compliant Question Areas: Miscellaneous Questions 'Record Keeping Land Application Site ■ Pathogen and Vector Attraction /2 :/5 Exit Time: 44-36AM Phone: bw, y g6-C73i?- Phone: Q49�4 Phone:.-04-gz^6— Phone: 828-296-4500 Inspection Type: Compliance Evaluation Treatment Transport (See attachment summary) V2y� N ,�� Pr ' U-C, A a �C t✓� on ir-wo/ ,S�SQ- �n CL doo _e N Sampling s c�� A k S&C/ - � A what I Page: 1 Permit: WQ0005763 Owner - Facility: Tuckaseigee Water & Sewer Authority Inspection Date: 02/02/2007 Inspection Type: Compliance Evaluation Reason for Visit: Routine Inspection Summary: 4�, P, U � n� �14 /1 Page: 2 Permit: WQ0005763 Owner - Facility: Tuckaseigee Water & Sewer Authority Inspection Date: 02/02/2007 Inspection Type: Compliance Evaluation Reason for Visit: Routine Record Keeping Yes No NA NE Is GW monitoring being conducted, if required? ❑ Cl f�l ❑ Are GW samples from all MWs sampled for all required parameters? ❑ ❑ ❑ Are there any GW quality violations? ❑ ❑ 0 ❑ Is GW-59A certification form completed for facility? ❑ ❑ ❑ Is a copy of current permit on -site? M ❑ ❑ ❑ Are current metals and nutrient analysis available? 10 ❑ ❑ ❑ Are nutrient and metal loading calculating most limiting parameters? 0 n n n a. TCLPanalysis?Mot) (DI& JIa- r)04 re�r� Z ❑ ID ❑ ❑ 2S i A U AIS diS+. 1 n w b. SSFA (Standard Soil Fertility Analysis)? otd,,.��, ❑ ❑ M ❑ Are PAN balances being maintained? ❑ ❑ !o ❑ Are PAN balances within permit limits? ❑ ❑ fil ❑ Has land application equipment been calibrated? "®4 so 0 ❑ go ❑ Are there pH records for alkaline stabilization? 00 cvss ��� `od ❑ ❑ ❑ LM no alv4X'ne' S�ab►�i7���� Are there pH records for the land application site? n n ❑ r Are nutrient/crop removal practices in place? ❑ ❑ ❑ Do lab sheets support data reported on Residual Analysis Summary? go ❑ ❑ ❑ Are hauling records available? W,4, WV)AY"A- t,6'.eA' 6'4' ❑ ❑ ❑ Are hauling records maintained and up-to-date? M ❑ ❑ ❑ # Has permittee been free of public complaints in last 12 months? 0 ❑ ❑ ❑ Has application occurred during Seasonal Restriction window? ❑ ❑ L ❑ Comment: Pathogen and Vector Attraction Yes No NA NE a. Fecal coliform.SM 9221 E (Class A or B) ❑ ❑ ❑ Class A, all test must be <1000 MPN/dry gram Geometric mean of 7 samples per monitoring period for class B<2.0*10E6 CFU/dry gram ❑ Fecal coliform SM 9222 D (Class B only) ❑ ❑ 02 ❑ Geometric mean of 7 samples per monitoring period for class B<2.0*10E6 CFU/dry gram ❑ b. pH records for alkaline stabilization (Class A) ®❑ ❑ ❑ c. pH records for alkaline stabilization (Class B) ❑ ❑ (M ❑ Page: 3 Permit: WQ0005763 Owner - Facility: Tuckaseigee Water & Sewer Authority Inspection Date: 02/02/2007 Inspection Type: Compliance Evaluation Reason for Visit: Routine Temperature corrected im d. Salmonella (Class A, all test must be < 3MPN/4 gram day) n n IN n e. Time/Temp on: @ Q ❑ ❑ Digester (MCRT) fl Compost Q Class A lime stabilization f. Volatile Solids Calculations n n W111 n g. Bench -top Aerobic/Anaerobic digestion results ❑ Comment: Treatment Check all that apply Aerobic Digestion LE Anaerobic Digestion 1 Alkaline Pasteurization (Class A) j-PoW A° aH roue 30 +� • ( �� dime ? Q Alkaline Stabilization (Class B)hf-�G�min�.�ye��d Compost Drying Beds Other rl Comment: Q Sampling �,-el'J �i3O^_ llolvu[rgW0 b�"` Yes No NA NE - — .................... Y LJ Describe sampling: SarrP�4_5 l CUji` Is sampling adequate? (j ra'6ds �^' s �❑ I_l � �r Is sampling representative? Comment: Is\coof the p rmit in the transport vehicle? Is th41rol spill control plan in the vehicle? 0 ❑ QIs plan satisfactory? n n n n Does tran ort hicle appear to be maintained? ❑ ❑ ❑ Comm nt: Page: 4 Permit: WO0005763 Owner - Facility: Tuckaseigee Water & Sewer Authority Inspection Date: 02/02/2007 Inspection Type: Compliance Evaluation Reason for Visit: Routine Land Application Site 1 A Yes No NA NE Is a copy of the permit on -site during application ev nts? ❑ Cl ❑ ❑ tion site in overall good condition? Is�\he ❑ ❑ ❑ ❑ Is te of runoff/ponding? ❑ ❑ ❑ ❑ If phe application equipment in go d operating condition? ❑ n ❑ ❑Areeing maintained? ❑ ❑ ❑ ❑ Are opes buffered? 10% for surtaCe application n n n n 18% for subsurfa a application ❑ ❑ ❑ n Are there access rest ictions and/o signs? Is the application site fr of odo s or vectors? Have performance require e s for application method been met? For injection? For incorporation? Does permit require m nitoring w Is? Have required MWs een installed? Are MWs properly ocated w/ respect to B and CB? Are MWs prope y constructed (including reened interval)? Is the surro If Annual R Are soil t p Is the ater Is ap licatioi Co ment u ding area served by public wat sport indicates overapplication of F es consistent w/ Soil Scientist repo table greater than 173' bls. are wells nearby that may be impacted? occurring at the time of the inspection? ❑n❑❑ ❑❑❑❑ Page: 5 ace Analytical ° www. pacelabs. com ,_,„ January 10, 2006 Mr. Stan Bryson '' Tuckaseigee:-;Water & Sewer Auth 1246 West' Main Street Syl•v, 'NC 28779 RE: Lab Project Number:.92109812 Client Project ID: ` TCLP Dear Mr. Bryson: Pace Analytical Servicta; ,;;c. 9800 Kincey Avenue, Suite 100 Huntersville, NC 28078 Phone: 704.875.9092 Fax., 704.875.9091 Pace Analytical Services, Inc. 2225 Riverside Drive Asheville, NC 28804 Phone: 828.254.7176 Fax: 828.252.4618 Enclosed are the analytical results for sample(s) received by the laboratory on December 20, 2005. Results reported herein conform to the most'current NELAC standards, where applicable, unless otherwise narrated in the body of the report. Inorganic Wet Chemistry and Metals Analyses were performed at our Pace Asheville laboratory and Organic'testing was performed at our Pace Charlotte laboratory unless otherwise footnoted. If you have any questions concerning this report please feel free to contact me. Since ,,7 imwoipill iams - _._Tom .Williams@pacelabs. com_ Project Manager Enclosures Asheville Certification IDS NC Wastewater 40 NC Drinking Water 37712 SC 99030 P NIP AP PR7AAR - 'REPORT OF LABORATORY ANALYSIS . This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc. tl RCCOB Charlotte Certification IDs NC Wastewater 12 NC Drinking Water 37706 SC 99006 rl NCI no C:07a1)7 ace Analytical ° www.pacelabs.com Solid results are reported on a dry weight basis Lab Sample No: 926463092 Client Sample ID: TWSA #1 BIORESIDUAL Pace Analytical Ser►.,,,.., Inc. 9800 Kincey Avenue, Suite 100 Huntersville, NC 28078 Phone: 704.875.9092 Fax., 704.875.9091 Lab Project Number: 92109812 Client Project ID: TCLP Pace Analytical Services, Inc. 2225 Riverside Drive Asheville, NC 28804 Phone: 828.254.7176 Fax: 828.252.4618 Project Sample Number: 92109812-001 Date Collected: 12/20/05 00:00 Matrix: Soil Date Received: 12/20/05 12:02 Parameters Results Units Report Limit Analyzed By CAS No. Qual RegLmt Metals Trace ICP Metal,s_TCLP Leach. Method: EPA 6010 Date Digested Y 12/21/05 13:45 12/21/05 13:45 Trace ICP Metals, TCLP Leach. Prep/Method: EPA 3010 / EPA 6010 Arsenic ✓ 0.027 mg/1 0.025 12/23/05 15:16 ALV 7440-38-2 _,;:Barium ✓ 0.28 mg/l 0.025 12/23/05 15:16 ALV 7440-39-3 Cadmium ✓ NO mg/l 0.0050 12/23/05 15:16 ALV 7440-43-9 Chromium I✓ ND mg/l 0.010 12/23/05 15:16 ALV 7440-47-3 Lead k-' 0.041 mg/l 0.025 12/23/05 15:16 ALV 7439-92-1 Selenium ✓ 0.027 mg/l 0.025 12/23/05 15:16 ALV 7782-49-2 Silver, NO mg/l 0.010 12/23/05 15:16 ALV 7440-22-4 Date Digested 12/22/05 09:00 12/22/05 09:00 Mercury, CVAAS, TCLP Leachate Method: EPA 7470 Mercury V 0.00035 mg/l 0.00020 12/22/05 13:03 ALV 7439-97-6 GUMS Semi vol ati 1 es Semivolatile Organics, TCLP Prep/Method: EPA 3510 / EPA 8270 1,4-Dichlorobenzene ✓ NO mg/l 0.75 01/05/06 15:52 BET 106-46-7 2,4-Dinitrotoluene L/ NO mg/l 0.013 01/05/06 15:52 BET 121-14-2 Hexachloro-1,3-butadienek/ ND mg/l 0.050 01/05/06 15:52 BET 87-68-3 Hexachlorobenzene v NO mg/l 0.013 01/05/06 15:52 BET 118-74-1 Hexachloroethane ✓ NO mg/l 0.30 01/05/06 15:52 BET 67-72-1 2-Methylphenol (o-Cresol) NO mg/l 0.050 ' 01/05/06 15:52 BET 95-48-7 3&4-Methylphenol ✓ 0.60 mg/l 0.010 01/05/06 15:52 BET Nitrobenzene t-*" NO mg/l 0.20 01/05/06 15:52 BET 98-95-3 PentachlorophenolV`� NO mg/l 10. ~ 01/05/06 15:52 BET 87-86-5 Pyridine ✓ ND mg/l 0.50. 01/05/06 15:52 BET 110-86-1 _2_,4,5-Trichlorophenol✓__ NO mg/l _. __ 40_._._ __ .01/05/06 15:52. BET 95-95-4 . 2,4,6-Trichlorophenol4f NO mg/l 0.20 01/05/06 15:52 BET 88-06-2 Nitrobenzene-d5 (S) 72 Y. 01/05/06 15:52 BET 4165-60-0 2-Fluorobiphenyl (S) 63 % 01/05/06 15:52 BET 321-60-8 Terphenyl-d14 (S) 80 % 01/05/06 15:52 BET 1718-51-0 Phenol-d5 (S) 33 % 01/05/06 15:52 BET 4165-62-2 2-Fluorophenol (S) 48 Y. 01/05/06 15:52 BET 367-12-4 2,4,6-Tribromophenol (S) 71 % 01/05/06 15:52 BET 118-79-6 Date Extracted 01/04/06 01/04/06 I Date: 01/10/06 Asheville Certification IDs NC Wastewater 40 NC Drinking Water 37712 SC 99030 FL NELAP E87648 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc. \N a000R 1 Page: 1 of 12 Charlotte Certification IDs NC Wastewater 12 NC Drinking Water 37706 SC 99006 LI RIM AD E:07c1)'7 I aFpp" ceAnallytical'o www.pacelabs.com Lab Sample No: 926463092 Client Sample ID: TWSA #1 BIORESIDUAL Pace Analytical Services, Inc. 9800 Kincey Avenue, Suite 100 Hunters ville, NC 28078 Phone: 704.875.9092 Fax., 704.875.9091 Lab Project Number: 92109812 Client Project ID: TCLP Pace Analytical Services, Inc. 2225 Riverside Drive Asheville, NC 28804 Phone: 828.254.7176 Fax: 828.252.4618 Project Sample Number: 92109812-001 Date Collected: 12/20/05 00:00 Matrix: Soil Date Received: 12/20/05 12:02 Parameters Results Units Report Limit Analyzed By CAS No. Qual RegLmt GC Semivolatiles - Pesticides, TCLP Leachate Prep/Method: EPA 3510 / EPA 8081 gamma-BHC (Lindane)t/ NO mg/l 0.040 01/06/06 17:41 JEM 58-89-9 Chlordane ._ NO mg/l 0.0030 01/06/06 17:41 JEM 57-74.9 Endrin ►/ NO mg/l 0.0020 01/06/06 17:41 JEM 72-20-8 Heptachlor/ NO mg/l 0.00080 01/06/06 17:41 JEM 76-44-8 Methoxychlor l/ NO mg/l 1.0 01/06/06 17:41 JEM 72-43-5 Ioxaphene ND mg/1 0.050 01/06/06 17:41 JEM 8001-35-2 Tetrachloro-m-xylene (S) 52 % 01/06/06 17:41 JEM 877-09-8 Decachlorobiphenyl (S) 46 % 01/06/06 17:41 JEM 2051-24-3 Date Extracted 01/05/06 01/05/06 GUMS Vol ati l es Volatile Organics, TCLP Leach. Method: EPA 8260 Benzene NO mg/l 0.0050 01/03/06 14:05 DLK 71-43-2 2-Butanone (MEK) ✓ 0.62 mg/l 0.10 01/03/06 14:05 DLK 78-93-3 1 Carbon tetrachloride Ve ND mg/l 0.0050 01/03/06 14:05 DLK 56-23-5 Chlorobenzene ✓ ND mg/l 0.0050 01/03/06 14:05 DLK 108-90-7 Chloroform v" NO mg/l -0.0050 01/03/06 14:05 DLK 67-66-3 1,4-Dichlorobenzene 0.12 mg/l 0.0050 01/03/06 14:05 DLK 106-46-7 2 1,2-Dichloroethane ' NO mg/l 0.0050 01/03/06 14:05 DLK 107-06-2 1,1-Dichloroethene hj ND mg/l 0.0050 01/03/06 14:05 DLK 75-35-4 Tetrachloroethene b/ 0.0083 mg/l 0.0050 01/03/06 14:05 DLK 127-18-4 2 Trichloroethene 1/ NO mg/l 0.0050 01/03/06 14:05 DLK 79-01-6 Vinyl chloridel,' NO mg/l 0.0050 01/03/06 14:05 DLK 75-01-4 Toluene-d8 (S) 87 % 01/03/06 14:05 DLK 2037-26-5 4-Bromofluorobenzene (S) 71 % 01/03/06 14:05 DLK 460-00-4 3 Dibromofluoromethane (S) 45 % 01/03/06 14:05 DLK 1868-53-7 3 1,2-Dichloroethane-d4 (S) 88 % 01/03/06 14:05 DLK 17060.07-0 exyO �) a 5` 2-► Date: 01/10/06 1 Asheville Certification IN REPORT OF LABORATORY ANALYSIS NC Wastewater 40 NC Drinking Water 37712 This report shall not be reproduced, except in full, Sc 99030 without the written consent of Pace Analytical Services, Inc. FL NELAP E87648 Page: 2 of 12 Charlotte Certification IDs NC Wastewater 12 NC Drinking Water 37706 Sc 99006 GI RIFI AD C07Gn7 Pace Analytical Services, Inc. 'Pace Analytical Services, Inc. 9800 Kincey Avenue, Suite 100 2225 Riverside Drive Huntersville, NC 28078 Asheville, NC 28804 Phone: 704.875.9092 Phone: 828.254.7176 W , " NJ, 160 W I,,, Fax. 704.875.9091 Fax: 828.252.4618 www.pacelabs.com..; , 4- Lab Project Number: 92109812 Client Project ID: 7CLP PARAMETER FOOTNOTES Method 9071B modified to use ASE. All pH Free,Chlorine, Total' Chlorine and Ferrous Iron analyses conducted outside of EPA recommended immediate hold time; Depending on the moisture content the PRLs can be elevated for all soil samples reported on a dry weight basis. Wr 2-Chloroethyl vinyl ether has been shown to degrade in the presence of acid. ND Not detected at or above adjusted reporting limit NC Not Calculable J Estimated concentration above the adjusted method detection limit and below the adjusted reporting limit MDL Adjusted Method Detection Limit. (S) Surrogate [1] Compound concentration exceeds the calibration range of the instrument (CLP E-Flag). . [21 Sample results may be biased high due to,interference with internal standard. [31 The surrogate recovery was outside QC acceptance limits due to matrix interference. Date: 01/10/06 Page: & of 12 Asheville certificatibn IDs REPORT OF LABORATORY ANALYSIS Charlotte Certification IDs NC Wastewater 40 NC Wastewater 12 NC DrinkingWater 37712 This report shall not be,.reproduced, except in full, NC Drinking Water 37706 Sc 99030 without the written consent of Pace Analytical Services, Inc:01 SC 99006 - FL NELAP E87648 ,w�.IA°�9� Fi RIPI nv Gu7a1)7 Analytical Environmental Services, Inc. Date: 28-Dec-05 CLIENT: Pace Analytical Services, Inc. Client Sample ID: 926463092 Project: 92109812 Collection Date: 12/20/2005 Lab ID: 05121302-001 Matrix: SLUDGE Analyses Result Reporting Limit Qual Units BatchID Dilution Date Anal zed y .Factor HERBICIDES, TCLP SW1311/8151A (SW3510B) Analyst: MM 2,4,5-TP (Silvex) BRL 0.50 mg/L. 65731 1 12/23/2005 6:44 PM 2,4-D BRL 0.50 mg/L 65731 1 12/23/2005 6:44 PM Surr: DCAA 87.3 21.3-162 %REC 65731 1 12/23/2005 6:44 PM Qualifiers: * Value exceeds Maximum Contaminant Level BRL Below Reporting Limit H Holding times for preparation or analysis exceeded N Analyte not NELAC certified B Analyte detected in the associated Method Blank E Estimated (Value above quantitation range) S Surrogate Recovery outside accepted recovery,limits Narr See Case Narrative NC Not Confirmed Page 1 of 1 .� 7114 - Incident Report Report Number: 200602702 Incident Type: Other Category: Incident Incident Started: 08/15/2006 County: Jackson City: Sylva Farm #: Responsible Party: Owner: Tuckaseigee Water & Sewer Permit: WQ0005763 Facility: TWSA Class A EQ Residuals First Name: Joe Middle Name: Last Name: Cline Address PO Box 1051 City/State/Zip: Sylva NC 28779 Phone: Material Category: Estimated Qty: uOM On -Site Contact: First/Mid/Last Name: Stan Bryson Company Name: Phone: (828)586-5189 Pager/Mobile Phone: / Reported By: _ First/Mid/Last Name: Stan Bryson Company Name: Address: City/State/Zip: Phone: (828)586-5189 Pager/Mobile Phone: / Chemical Name Reportable Qty. lbs. Reportable Qty. kgs. DD:MM:SS Decimal Position Method: Latitude: Position Accuracy: Longitude: Position Datum: Location of Incident: TWSA Plant #1 Address: 1871 N River Rd City/State/Zip Sylva NC 28779 Report Created 08/28/06 10:20 AM Page 1 Cause/Observation: Truck loaded with municipal sludge turned over at the WWTP Approximately 25 tons of sludge spilled. Directions: From the intersection of Hwy. 441 and NCSR 1359 in Dillsboro, turn left onto NCSR 1359. Travel approximately 2 miiles to TWSA Plant #1, located on the left. Action Taken: Comments: TWSA employees worked until 10:30pm on the 15th removing 5-day report was received on 8/24/2006. All sludge was removed from sludge from the mouth of a culvert at the spill site. The sludge spill site. The spill site was topdressed with clean soil, lime and straw. did not run into the culvert. Cleanup continued and was completed on the 16th. A 5 day report was requested by DWQ APS. Incident Questions: Did the Material reach the Surface Water? No Surface Water Name? Did the Spill result in a Fish Kill? No If the Spill was from a storage tank indicate type. Containment? Yes Cleanup Complete? Yes Water Supply Wells within 1500ft: Unknowr Conveyance: Estimated Number of fish? (Above Ground or Under Ground) Groundwater Impacted : Unknown Event Type Event Date Due Date Report Entered 2006-08-28 09:42:00 Incident closed 2006-08-28 12:00:00 Referred to Regional Office - Primary Contact 2006-08-17 10:00:00 Requested Additional Information 2006-08-17 12:00:00 Report Created 08/28/06 10:20 AM Comment 5-Day Report Page 2 Report Received 2006-08-16 10:00:00 Incident Start 2006-08-15 06:00:00 Standard Agencies Notified: Agency Name Phone First Name M.I. Other Agencies Notified: Agency Name Phone First Name M.I. DWQ Information: Report Taken By: Report Entered By Keith Haynes Beverly Price Last Name Contact Date Last Name Contact Date Regional Contact: Beverly Price Phone: Date/Time: 2006-08-16 10:00:00 AM 2006-08-28 09:42:00 AM 2006-08-17 10:00:00 AM Referred Via: Phone Voice mail Did DWQ request an additional written report? 2006-08-17 12:00:00 AM If yes, What additional information is needed? 5-Day Report Report Created 08/28/06 10:20 AM Page 3 Tuckaseigee Water & Sewer Authority Serving Jackson County 1246 West Main Street Sylva, NC 28779 Ph. (828) 586-5189 Fax (828) 631-9089 July 21, 2006 Attn: Beverly Price NC Div. of Water Quality 2090 US 70 Hwy Swannanoa NC 28778 Subject: Sludge spill by hauler at TWSA Plant #1 Ms. Price, H ECIEW WED AUG 2 4 2006 Asheville Regional Office _ ��tai{er i'rofeclion ✓ The Tuckaseigee Water and Sewer Authority uses private haulers to haul municipal sludge to a landfill in Georgia. On the evening of Tue Aug. 15th, we loaded a truck owned by Banks Trucking of Asheville, with approx 25 tons of sludge. As the driver was leaving the loading station the rear of the trailer slid off an embankment and turned the truck and trailer over on its side. Fortunately no one was hurt in the accident, but as you can see by the pictures taken that evening the cleanup was quite a challenge. Twsa employees worked until 10:30 on the evening of the 15th to remove sludge from in and around the mouth of a culvert at the site of the spill. Due to the dryness of the sludge (approx. 20%), this material did not run into the culvert where it could have been washed to a drainage ditch. and eventually to the Tuckaseigee River. Upon securing the area around the culverta decision was made to wait until daylight to finish removal and cleanup. On Wed. Aug 16, TWSA employees worked to load the sludge on our truck and haul it back up on the pad. Residual left on the asphalt was washed down the drive, past the silo in the picture, to a drain that leads back to the influent to the plant. Cleanup of the area around the asphalt required removing some of the topsoil. This area was topdressed with clean dirt and lime and straw was added to prevent erosion. This was all accomplished by four o'clock on Wed Aug 16th and the cleanup was declared complete. I am extremely gratified by the way that TWSA employees rose to the occasion. I had been very concerned that afternoon thunderstorms might cause heavy rains which would not only have made cleanup more difficult but could have resulted in sludge being washed to the river. Thanks to the dedication of our employees, a difficult job was handled in a speedy -and efficient manner. If you have questions or comments, please do not hesitate to contact me. Sincer y, i Stan Bryson Wastewater Superintendent Tuckaseigee Water and Sewer Authority xc:Joe Cline, Executive Director, TWSA ��� _., , �- .� .. � ,� }f ...._ .� _ � t � _ d ��•� � � � Yt 4p� L �.. •. ^'t i ,.,y � ` „� ,y. ^� t F C r � i' �� T .. r � �` �� .. r�--� �,� � -,� y _ r r , ' � r � � ��, !� ��-F. r. � �. � ���r � . ��. 1 ,� I � .. H -' +4, e �� .. � s M r 4 i r. � � � x ��J. r� • p5� �" ��. .t.a� 'S. - �`'S � �, ,, k .six ��' ,S.-+,• ,-�'+.. x �' €:i � � i' . Y �'} • -'t�,�..y� u� �y py � `# J6�r �ti � � �i 6fT, $tr`y P �.,t�'Y+E.-,.+. -• t 1 _. +• .. ,. �`,. Tom_ w � r - .- . e .1 `l b YG �i k..J •iF+7y�� �h 4 ':" 4 �g-f 4 /r'v �+ } �- ` a� C ��� � L..c.t� �`S�r-'i���pp�i,,t',�,%�.Jt•«��- �,t._ ,A„`��,'`k rr� ��- � t - � .;r ���'' �'��:g y _ 03/20,12006 15:30 919-715-604B D4JQ NON DISCHARGE•BR PAGE 01/01 Tuckaseigee Water & Sewer Authority � �� V semng Jackson Comty 1246 West Main Street p Sylva, NC 28779�-- Ph. (828) 55s-5189 _..._ -._.. Fax (82816314,089 Feb 21, 2006 1 ECEIVEDIDENRIOVVQ J.R. Joshi AQb1FER ppCTf lU I COON Aquifer Protection Section 1636 Mail Service Center MAR 0 7 2006 Raleigh NC, 27699-1636 Subject: Cover for pad at Sludge Managomcrit Facility Tuckaseigee Water and Sewer .Authority Permit HNVQ0005763 Dear Mr. Joshi, As we discussed shortly after the permit renewal, the TWSA is currently in negotiations for an SOC. Part of the 80C is an expansion of the TW SA Plam Al wastewater facility - The following timeline has been subrWned as a part of the SOC. 1) Completion of Preliminary Engineering Report March 1, 2006 2) Subn-it NPDES Renewal with Flow increase. AyD 1, 2007 3) Submit plans and specs for upgrade after issuance of pernut Mk 1, (—) 4) Notice to proceed for construction. March 1, 9-0 9 5)Complete construction AuZ-1,2M The sludge management and storage areas will be adressed it) the upgrade/expar sioD outlined above. If you have questions or coinments please do not hesitate to contact me. Sincer�lY, Stan Bryson Wastewater Operations Superintendent Tuckaseigee Water and Sewer Authority xc:Joe Cline, Executive Director, TWSA RECEIVED MAR 21 2006 Asheville Regional Office Tuckaseigee Violater & Sewer Authority Serving Jackson County 1246 West Main Street Sylva, NC 28779 Ph. (828) 586-5189 Fax (828) 631-9089 Oct. 12, 2005 J.R. Joshi AquiferProtection Section 1636 Mail Service Center Raleigh NC 27699-1636 Subject: Permit Renewal Permit No. WQ0005763 Dear Mr. Joshi, The Tuckaseigee Water and Sewer Authority received the permit for Class A EQ Residuals (WQ0005763). We are in agreement with all of the conditions as set forth 'in the permit except for Conditon I. 1. This condition requires us to provide the pad with an overhead cover within 180 calendar days of issuance of the permit. We respectfully ask that this condition be waived or the time frame extended for the following reasons: We are currently entering into negotiations with the State of North Carolina, Div. of Water Quality for an Special Order of Consent (SOC) for the TWSA Plarit #1 (NPDES #NC0039579). We believe that the SOC might be ready to implement by the end of Dec. 2005. As part of this negotiation, upgrades to the sludge facility and the plant itself are being contemplated. The costs to cover the existing pad are substantial and I am reluctant to build a cover over an area that might be needed for plant expansion. The current treatment scheme for both Wastewater and Residuals will be evaluated so that a pertinent and effective plan for expansion can be implemented. We respectfully submit that we be allowed to develop the details of this plan before implementation of Condition I.1. Your thoughts and direction on this matter will be greatly appreciated. Thank y in advanc Stan Bryson Wastewater Operations Superintendent Tuckaseigee water and Sewer Authority xc: Joe Cline, Executive Director, TWSA Forrest Westall, McGill Associates Victor Lofquist, Lofquist & Associates Roger Edwards, NC Div. of Water Quality, ARO ` W,y rF Michael F. Easley, Govemor O� 9pG William G. Ross Jr., Secretary North Carolina Departmen nvironment and Natural Resourc69 r Alan W. Klimek, P.E. Direct_ >_ Division of Water 0uality` a Asheville Regional Office AQUIFER PROTECTION'a July 11, 2005 Jerry R King, Executive Director Tuckaseigee Water & Sewer Authority 1246 West Main Street Sylva, N.C.28779 SUBJECT: June 22, 2005 Compliance Evaluation Inspection Tuckaseigee Water & Sewer Authority Distribution of Class A Wastewater Residuals Program Permit No: WQ0005763. Jackson County Dear Mr. King: Enclosed please find a copy of the Compliance Evaluation Inspection form from the inspection conducted on June 22, 2005. Beverly Price of the Asheville Regional Office conducted the Compliance Evaluation Inspection. The facility was found to be in Compliance with permit WQ0005763. The following items should be addressed with regard to the Annual Report: 1) It is recommended that the laboratory results (from contract labs) be included in the Annual Report. 2) All metals results should be included on the Residuals Sampling Summary Form in the Annual Report. 3) Aluminum was not included in the 2004 residuals analysis. Additionally, the Authority should begin working toward obtaining a certified back-up operator for the residuals program,.as this is a requirement of the permit. The assistance of Mr. Stan Bryson was greatly appreciated during the inspection. Please refer to the enclosed inspection report for additional observations and comments. If you or your staff has any questions, please call me at 828-296-4500 Ext.4685. Sincerely, Y Beverly rice Enclosure cc: Stan D. Bryson, ORC WWTP A--q• if�r 'Pr�tecticrn =ti • sh01le ills ,No e NhCarolina aturally 2090 U.S. Highway 70, Swannanoa, NC 28778 Telephone: (828) 296-4500 Fax: (828) 299-7043 Customer Service 1 877 623-6748 Permit: WQ0005763 Owner - Facility: Tuckaseigee Water & Sewer Authority Inspection Date: 06/22/2005 Inspection Type: Compliance Evaluation Reason for Visit: Routine I.y.RE. Distribution and Marketing Record K .. ina Is GW monitoring being conducted, if required? Are GW samples from all MWs sampled for all required parameters? Are there any GW quality violations? Is GW-59A certification form completed for facility? Is a copy of current permit on -site? Are current metals and nutrient analysis available? Are nutrient and metal loading calculating most limiting parameters? a. TCLP analysis? b. SSFA (Standard Soil Fertility Analysis)? Are PAN balances being maintained? Are PAN balances within permit limits? Has land application equipment been calibrated? Are there pH records for alkaline stabilization? Are there pH records for the land application site? Are nutrient/crop removal practices in place? Do lab sheets support data reported on Residual Analysis Summary? Are hauling records available? Are hauling records maintained and up-to-date? Has permittee been free of public complaints in last 12 months? Has application occurred during Seasonal Restriction window? Comment: Permit expired 9/30/01. Permit renewal application sent in 10129101. Permit is in renewal status. Pathogen and Vector Attraction a. Fecal coliform. SM 9221 E (Class A or B) Class A, all test must be <1000 MPN/dry gram Geometric mean of 7 samples per monitoring period for class B<2.0*10E6 CFU/dry gram Fecal coliform SM 9222 D (Class B only) Geometric mean of 7 samples per monitoring period for class B<2.0*10E6 CFU/dry gram b. pH records for alkaline stabilization (Class A) c. pH records for alkaline stabilization (Class B) Temperature corrected d. Salmonella (Class A, all test must be < 3MPN/4 gram day) e. Time/Temp on: Digester (MCRT) Compost Class A lime stabilization f. Volatile Solids Calculations g. Bench -top Aerobic/Anaerobic digestion results Comment: Yes No NA NE ❑ ❑ ■ ❑ ❑ ❑ E ❑ ❑ ❑ E ❑ ❑❑■❑ ■ O O ❑ ■❑❑❑ ■ ❑ ❑ ❑ ❑ O ■ O ❑ ❑ E ❑ ❑ ❑ ■ ❑ ❑ ❑ E ❑ ❑ ❑ ■ ❑ ■ ❑ ❑ ❑ ❑ ❑ N ❑ O ❑ ■ ❑ ❑ ❑ ❑ ■ ❑ ❑ O ■ O O ❑ E.0 ❑ ❑ ❑ ❑ ❑ Yes No NA NE ❑ ❑ ❑ E ❑ ❑ ❑ ❑ ❑ E ❑ 13 ❑-❑■❑ E ❑ ❑ ❑ 13 ❑ ❑ E ❑ ❑ ❑ ■ ❑ Page: 2 M Compliance Inspection Report Permit: WQ0005763 Effective: 10/18/96 Expiration: 09/30/01 Owner: Tuckaseigee Water & Sewer Authority SOC: _ Effective: Expiration: Facility: Tuckaseigee Water and Sewer Authority Residuals Composting Facility and Distribution County: Jackson RMr"iver Rd Region: Asheville Sylva NC 28779 Contact Person: Jerry R King, Director Executive Phone: 704-586-5189 Ext. Directions to Facility: Primary ORC: Stan D Bryson Secondary ORC(s): On -Site Representative(s): Related Permits: Inspection Date: 06/22/2005 Primary Inspector: Beverly Price Secondary Inspector(s) Certification: 13180 Entry Time: 11:30 AM Exit Time: 01:30 PM Reason for Inspection: Routine Permit Inspection Type: Distribution of Residual Solids (503) Facility Status: ■ Compliant 0 Not Compliant Question Areas: Miscellaneous Questions Record Keeping ■ Land Application Site ■ Pathogen and Vector Attraction Phone: 828-586-9318 Phone: 828-296-4500 Ext.4655 Phone: Phone: Inspection Type: Compliance Evaluation Treatment Sampling Transport Inspection Summary: The inspection consisted of a tour of the facilities and a records review. The facility appeared to be well maintained and operated. Finished product is stored on a concrete pad. Any leachate is directed back to the head of the WWTP for treatment. Class A residuals were last produced in March '05. At the present time, residuals are being land filled. The facility should begin working toward getting a certified back-up operator as this is a permit condition. It is reccommended that the laboratory results ( from contract labs) be included in the Annual Report. In addition, all metals results should be included on the Residuals Sampling Summary Form in the Annual Report. Aluminum was missing from the residuals analysis. Page: 1 Permit: WO0005763 Owner - Facility:, Tuckaseigee Water& Sewer Authority Inspection Date: 06/22/2005 Inspection Type: Compliance Evaluation " Reason for Visit: Routine Yes No NA NE Treatment Check all that apply Aerobic Digestion ❑ Anaerobic Digestion Alkaline Pasteurization (Class A) Alkaline Stabilization (Class B) Compost Drying Beds Other Comment: Yes No NA Sampling Describe sampling: 15-20 grab samples are collected from different sections of the pile and then composited. —NE Samples are collected, from the oldest and newest sections of the residuals pile. Is sampling adequate? Is sampling representative? 0 ❑ 00 Comment: Page: 3 J Annual Report Review SOP - -- - a-oo �( I. Annual Land Application Certification Form • Was a cue , lEa{tion form submitted? ye-5 • Was 1aa13d-app}tcuatroti conducted during the reported year? y� • How many dry tons and dry tons per acre were applied?NA • Were the applications within the permitted amount? NA • Verify PAN if more than 10 tons/acre tjA Did it indicate compliance? y4-5 • Was it signed by the appropriate people? Y aj 2. Monitoring • Were the analyses conducted at the required frequency? • Were the metals analyses reported on the Residual Sampling Summary Form?ldb p 5 • Were the results reported in mg/kg?yes • . Were the heavy metals within ceiling concentration permit limits?*y4.5 • If no, were the lab analyses attached? • Were all the required parameters tested? g/ # PAN ,�1tss,�g SPAN go�l4�Ges �6���� • Was TCLP analysis conducted'. pu 3. Field Summary NA • Were the land application events recorded on the Field Summary Forms? • Was a Field Summary Form submitted for each field? • Were all the residuals applied to permitted land? • Were all the residuals applied from permitted sources? • Were the field loading rates for each metal and PAN calculated (year to date)? • Were the cumulative pollutant loading rates calculated? • Were the calculations correct? • Were the PAN loading rates within permit limits? • Were the heavy metal cumulative pollutant loading rates within permit limits? • Were the residuals applied on a suitable crop? • Were the applications conducted during the crop's growing season? • Were the Field Summary Forms complete? 4. Pathogen and Vector Attraction Reduction • Was a signed copy of the Pathogen and Vector Attraction Reduction Form submitted?y of • Did the form indicate the period of coverage, the residual class, and the pathogen reduction alternative and the vector attraction reduction option used?y-a5 4b5 • Was the appropriate documentation to show pathogen and vector attraction reduction included in the report?X0 • Was pathogen and vector attraction reduction demonstrated according to 40 CFR Part 503? —eS 5. Soil Tests NA • Was a Standard Soil Fertility Analysis conducted for each application field? • Were the soil pH's 6.0 or greater for each application field? • Were the copper and zinc indexes in the soil less than 3000 for each application field? 6. General • Was the report in the proper format?q6� Were any parts of the annual report missing? sk"a 5 Was the report submitted on time?y J * Any violations of ceiling concentrations should be reported to Pretreatment for municipalities only. ■ Record Keeping ■ Pathogen and Vector Attraction Compliance Inspection Report Permit: WQ0005763 Effective: 10/18/96 Expiration: 09/30/01 Owner: Tuckaseigee Water & Sewer Authority SOC: Effective: Expiration: Facility: Tuckaseigee Water and Sewer Authority Residuals Composting Facility and County: Jackson 1N7triNijj0ftPjqram Region: Asheville Sylva NC 28779 Contact Person: Jerry R King, Director Executive Phone: 704-586-5189 Ext. Directions to Facility: a Primary ORC:Certification: 13� $ Phone: Secondary ORC(s): On -Site Representative(s): Related Permits: Inspection Date: ''D ['m/os Entry Time: Primary Inspector: Beverly Price Secondary Inspector(s): Reason for Inspection: Routine Permit Inspection Type: Distribution of Residual Solids (503) Facility Status: ❑ Compliant ❑ Not Compliant Question Areas: Miscellaneous Questions. ■ Land Application Site Exit Time: j 3 D Phone: 828-296-4500 Ext.4655 Phone: Phone: Inspection Type: Compliance Evaluation O� j( ■ Treatment ■ Sampling ■ Transport �' Inspection Summary: p f— f� �Qry C�q G C( t. / d %LCS 7�'�- ld � as►�/M�-�l �i '-G �✓ �- �� -�—' �a11� � � pUY 1 i� LW PA N c4 `/ c�G�ti,.,hat � cAe k�,/ � �° ° c /nC 16Ld-,- /,cab yea q. Page: 1 Permit: WQ0005763 Owner - Facility: Tuckaseigee Water & Sewer Authority Inspection Date: Inspection Type: Compliance Evaluation Reason for Visit: Routine Record Keeping Yes No NA NE Is GW monitoring being conducted, if required? ❑ ❑ ® ❑ Are GW samples from all MWs sampled for all required parameters? ❑ ❑ W ❑ Are there any GW quality violations? ❑ ❑ ® ❑ Is GW-59A certification form completed for facility? ❑ ❑ ® ❑ nn tn1 Is a copy of current permit on -site? ,PnMI�1r�C'� J«I` ❑ ❑ ❑ Are current metals and nutrient analysis available? ® ❑ ❑ ❑ Are nutrient and metal loading calculating most limiting parameters'] np'� p ddY ® ❑ ❑ Cl a. TCLP analysis? (�1pU. (�, '04 b-:� pJ","w " (Lf� �LLI ❑ ❑ ® ❑ 0-1 b. SSFA (Standard Soil Fertility Analysis)? ❑ ❑ Pj ❑ Are PAN balances being maintained? Cl ❑ ® Cl Are PAN balances within pennit limits? ❑ ❑ 01 ❑ Has land application equipment been calibrated? ❑ ❑ ` IM ❑ Are there pH records for alkaline stabilization? M ❑ ❑ ❑ Are there pH records for the land application site? ❑ ❑ ® ❑ Are mttriendcrop removal practices in place? ❑ ❑ ® ❑ Do lab sheets support data reported on Residual Analysis Summary? QM ❑ ❑ ❑ Are hauling records available? D 5SA c 24c" T M ❑ ❑ ❑ Are hauling records maintained and up-to-date? 42 ❑ ❑ ❑ Has permittee been flee of public complaints in last 12 months? M ❑ ❑ ❑ Has application occurred during Seasonal Restriction window? a+ In 4,9d- 93 ❑ ❑ ❑ Comment: /v O 16 5' e0 I & AAAUA- R4,(,'6f f — C �C� — r{G O /xm17 CVF n J Pathogen and Vector Attraction fej—, rq�.r Yes No NA NE 1 a. Fecal coliform SM 9221 E (Class A or B) mPN 3, l� IN ❑ ❑ ❑ Class A, all test must be <1000 MPN/dry gram Geometric mean of 7 samples per monitoring period for class B<2.0* I OE6 CFU/dry gram ❑ Fecal colifo m SM 9222 D (Class B only) ❑ ❑ ® ❑ Geometric mean of 7 samples per monitoring period for class B<2.0* 10E6 CFU/dry gram ❑ b. pH records for alkaline stabilization (Class A) UK- p tJ- C or.-4CA-A'� [9 ❑ ❑ ❑ c. pH records for alkaline stabilization (Class B) ❑ ❑ a ❑ Temperature corrected ❑ d. Salmonella (Class A, all test must be < 3MPN/4 gram day) ❑ ❑ 99 ❑ e. Time/Temp on: ❑ ❑ ❑ ❑ Digester (MCRT) ❑ Compost ❑ Class A lime stabilization ig f. Volatile Solids Calculations ❑ ❑ N ❑ g. Bench -top Aerobic/Anaerobic dligestion results El 00 ❑ m Coment:.AM0,� Rll, + b"Ct 0' WVnro� �inL J Treatment Yes No NA NE Check all that apply Page: 2 Permit: WQ0005763 Owner -Facility: Tuckaseigee Water & Sewer Authority Inspection Date: Inspection Type: Compliance Evaluation Reason for Visit: Routine Aerobic Digestion ❑ Anaerobic Digestion ❑ Alkaline Pasteurization (Class A) Alkaline Stabilization (Class B) ❑ Compost ❑ Drying Beds ❑ Other I ❑ Comment: )/1 (eel- w4 64 1P,,. Sarnplina • �..� n,0� ��.���,,,f- Yes No NA NE� �` d /'t{, i�iw G`U /1''�•j'%' .L. ^..G.(G cS2,�.y��-e Ca a 62 �-V //2 ui ,i Describe sampling: Is sampling adequate? Y�� i ❑ ❑ ❑ ❑ Is sampling representative? 11 ❑ ❑ ❑ Comment: a copy of the ermit in the transport vehicle? is a c of e spill control plan in the vehicle? Is the spill trol plan satisfactory? Does tr nsport ve i' e appear to be maintained? Comment: Land Application Site Is a copy of the permit on -site during applicati n events`? the application site in overall good condi 'on? Is t site free of runoff/ponding? If prose t, is the application equipmen m good operating condition? Are buffe Bing maintained? Are limiting sl es buffered? 10% for surface a p ' 18% for subsurface; Are there access restr Is the application site Have performance rei For injection? For incorporation's signs? or vectors? r application method been met? Does permit rYerly e monitoring wells? Have requireds been installed? Are M Ws pr locatedw/ respect to RI3 an CB'? Are MWs pfoperly constructed (including screene interval)? Is the surr unding area served by public water? If Annu• I Report indicates overapplication of PAN, are ells nearby that may be impacted? Are so' types consistent w/Soil Scientist report/evaluatio '? Is th water table greater than 1'/3' bls. Yes No NA NE ❑❑❑❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ Yes No NA NE ❑ ❑ ❑ ❑ ❑❑❑❑ ❑ ❑ ❑ ❑ ❑❑❑❑ ❑ ❑ ❑ ❑ ❑❑❑❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ Cl Cl ❑ ❑❑❑❑ ❑❑❑❑ ❑ ❑ ❑ ❑ ❑ ❑ Cl ❑ ❑ ❑ ❑ ❑ Page: 3 Permit: WQ0005763 Owner - Facility: Tuckaseigee Water & Sewer Authority Inspection Date: Inspection Type: C Barite Evaluation occurring at the time Comment: �f& � Lles �0 /Z4'—' , Na CdlivL�� n 0 6-3 bA-e-L h� AA C�� �- ��� p�-a c� l,�c.eo� ►�i'1 tea`-�'G` � 0 i Reason for Visit: Routine Page: 4 NCDA.A t!b�m,c,Diis.ion 00, Creek:Road.. Ralet h NC: Z 646 2Gr = n No 1;. _. .,4. eed _. .60.:7. al W05`85,7 W:. 3 .._. Y,,__..-.Report Grotuer:• Tuckaseigee Water & Sewer Copies To: 1246 West Main St Sylva, NC 28779 77;ds re re n d to identify optimum application s. .Waste Ana �: an4ilrE? {, �is � ®rt Iann TWSA 1 y 2/ 6/04 Jackson County Sample dD: N P K Ca M9 S Fe Mn Zn Cu B Mo Cl C TtiVS'r11 R Total 13332 _ 3687 . 931 244912 3231 1266 3936 223 1'45 80.6 8.78 IN -N Wa,`- "ode: -NH4 M1:: -NO3 _ Na Ni Cd Pb Al Se Li pH SS CrN DM% CCE% _ALE(tons) Description: OR-N 242 4.77 0.38 3.57 12.08 87.69 43.75 2.40 Municipal (Lime Stab.) Urea Recommendatio s n.,., ,. „ .. ,.. r,, '. ?, JNutrients A�ztla e.for. tYzrs . ro t lbs ton �uet:Ga is 1.G U / s Other{L�lementsa 3 r ,; : :-: lbs tonK uet Ucis�s ... .., ,. 13ioadcast.,_ :. .... ; ":', a �Si ' � �, , 6 6 8 9 1 6< 74 4 ,257 r p-. t tra Iz n val te.} .verso .el:..h : r. i , : r" o, ..f, e.waste, _odr c t shouldF,lae' . lted.air tes•n eiled„fo..ad list soil E1xto the desired.,f np e p ',.�cro . rndue.C}iin •sPhe ALE }nillcat s lhe'amo.unt,oF thewaste, rodu,ct:needed to'a uaLthe a, Yg P, aPP a 1, P t &,, P,P P 9 ,, .. a. .• .. -... .. �•r 4':i:.`, e...t ,; ^a-' 1 d ( li� #. i!1-. £ =.I <t v tf"'Sw2 L. k "'t .. .,.•.. ,: ._: ..., -F 4. ,.ie _•�<rn1 tf.'.;, h �•[.. ".T {i''r.:. : •:_.:: r i...r;:: i� ,. S :..s y r.. ..1. ., 'r •' r , .', '1 a-,. ,. n p s�. M,.,. #� s :... e ::-.. / ]. �.: ,,. ! 1.,.�LS.q t i. nh �eutral�ztnp,va�ueof;onefo.n:'ol.co 'mer.o�alR �icultuial e...t �Y j �. ..,,.. ..-b:..:... ...... _.. .,.. .- .. ..,... ..,1 1 .: . .�.,� .. ak...: .y +:...h_ ..�k>,.....t t. ,..Ic.4 ._. .;n .,,,�... .., •F, .!,ki. ,. �, ...t-�, n, ., .�..... _ ,.,. a Jr.r...r.,.. .... .-.._:5> These municipal residuals were prepared by: Tuckaseigee 'Water and Sewer Authority 1871 North fiver Rd. Sylva NC 28779 ph: 828-586-9318 spared under authority of the North Carolina Dept. of Environment and Natural Resources, (Divison of Water Quality -Permit # WQ0005763) Application of this product to the land is prohibited except. in accordance with the instructions on this information sheet, (1) A minium ten foot buffer between application site and any public or private water supply (including wells) and any stream lake or river. (2) Product shall not be applied to any sit that is flooded, frozen or snow covered. (3) Adequate procedures shall be provided to prevent surface runoff from carrying any disposed or stored residuals into any surface waters, (4) Soil tests are recommended to identify optimum application rates. T iC, �lwA 0 Nh FEB 1 F ` ,! :..LAderstandinq the ante And, � ,:,: ;.:. Ott:. ,:�sf_ .p. ,.. Waste products must be disposed of in ways that protect the environment. The keys to proper disposal include analyzing the waste product and planning application rates based on agronomic requirements. The Waste Analysis Report provides information necessary to use these materials as a resource while protecting the environment. Sample Info This section contains sample identifiers, specifically the sample identification number, waste code, and description. These data are supplied by the grower on the information sheet submitted with each. sample. iratory Results Wastes can be analyzed for up to 20 elements. Routine analysis includes most of the nutrients that are essential for plant growth— N, P, K, Ca, Mg, S, Fe, Mn, Zn, Cu, B and Na, Other elements may be analyzed if they are potentially harmful to soil or plants when allowed to increase to excessive levels, For example, when the waste is a by-product from a municipality or industry, the heavy metals Cd, Ni and Pb are routinely included in the analysis. Upon request and if conditions warrant, certain waste types can also be tested for Al, Cl, Li and Mo. Results are reported in parts per million, If the sample is a compost oir compost ingredient, values for pH, SS, and C:N are reported; pH values are also reported for all liquid animal waste samples. DM% is reported for all dry waste samples. CCE% and ALE are reported for waste products that have neutralizing value. Recommendations This section can have three parts: (1) Nutrients Available for First Crop based on application method; (2) Other Elements that may impact application; and (3) agronomic comments indicating precautions that should be taken when using the waste. (1) Predictions of nutrients available for the first crop are based on estimates of mineralization rate and nutrient loss, depending on application method. Estimates are reported in Ibs/ton for solid wastes and Ibs/1000 gallons for liquid wastes. "T" indicates that an element is present in a "trace" quantity (< 0.005 lb per measured unit). Within the first month after waste application, 50 to 75% of the nutrient quantities listedwill become available for the crop, Therefore, plan to apply wastes near the time that plants will require nutrients, The remaining nutrients gradually become available over the next three months, Nutrients not available for the first crop are mineralized to available forms over time, usually years. Certain nutrients, such as Zn and Cu, may accumulate in the soil in significant quantities. If waste is routinely applied, monitor nutrient accumulation with soil tests at least once every two years. Some cropping systems and metal levels may necessitate annual soil samples as well. ALE and CCE% are reported for wastes that may have neutralizing value. ALE indicates the amount of the waste product required to equal 1 ton of good quality agricultural lime (CCE%=90). If waste materials have significant neutralizing value, apply them only at rates necessary to optimize pH. For flexibility, the information sheet allows two choices for application method. Predictions of available nutrients are based on the type of waste and the method of application. If you decide to change the application method after the analysis is complete, contact the Agronomic Division at (919) 733- 2655 for a revised recommendation. (2) Quantities of other elements that may have an impact on the environment—Na, Ni, Cd, Pb, Al and Li —indicate the likelihood of harmful buildup in the soil. Like nutrients, they are reported in lbs/ton for solid wastes and lbs/1000 gallons for liquid wastes, (3) The recommendations section may include agronomic comments when warranted. These provide general information on the waste product and alert the user when plant nutrients or heavy metals are high enough to warrant special precautions when applying the waste. For diagnostic samples, site - specific recommendations are provided based on information sheet data. The more thoroughly the problem and its unique conditions are described on the information sheet, the more pertinent and site specific the recommendations will be, April 2003 10,000 copies of this public document were printed at a cost of $205.41 or $0.02 per copy. NON -DISCHARGE REGIONAL WATl.n QUALITY STAFF REPORT AND RECOMMENDATIONS �V To: Non -Discharge Permitting Unit NDPU Reviewer: Kevin Barnett Application No.: W00005763 Permitee: Tuckaseigee Water and Sewer Authority Regional Login No: GENERAL INFORMATION 1. This application is (cheek all that apply): ❑ New ® Renewal Fj Minor Modification 0 Major Modification ❑ Surface Irrigation Reuse 0 Recycle 0 High Rate Infiltration 0 Evaporation/Infiltration Lagoon Land Application of Residuals ❑ Attachment B included as appropriate ❑ 503 regulated ❑ 503 exempt ® Distribution of Residuals ❑ Surface Disposal 2. Was a site visit conducted in order to prepare this report? Yes or ® No. a. Date of site visit: b. Person contacted and contact information: Stan Bryson c. Site visit conducted by: d. Inspection Report Attached: ❑ Yes or ® No. 3. Is the following information entered into the BIMS record for this application correct? ® Yes or Fj No. If no, please complete the following or indicate that it .is correct on the current application. For Treatment Facilities: a. Location: Jackson County b. Driving Directions: From the intersection of US Hwy 441 and NCSR 1359 in Dillsboro, travel south (up the river) on NCSR 1359 1.9 mi. to the Tuckaseigee Water and Sewer Authority Plant # 1 on the left. c. USGS Quadrangle Map name and number: Sylva South 175-SW(F6SW) d. Latitude: 35o 20' 59" Longitude: 83o 14' 21" e. Regulated Activities / Type of Wastes (e.g., subdivision, food processing, municipal wastewater): municipal wastewaterresiduals For Disposal Sites: (If multiple sites either indicate which sites the information applies to, copy and paste a new section into the document for each site, or attach additional pages for each site) a. Location(s): b. Driving, Directions: c. USGS Quadrangle Map name and number: FORM: NDSRR 03/02 1 . NON -DISCI- ",RGE REGIONAL WATT QUALITY STAFF R-EPORT AND RECOMMENDATIONS { d. Latitude: Longitude: NEWAND MAJOR MODIFICATIONAPPLICATIONS (this section not neededfor renewals or minor modifications, skin to next section) DESCRIPTION OF WASTES) AND FACILITIES 1. Please attach completed rating sheet. Facility Classification: 2. Are the new treatment facilities adequate for the type of waste and disposal system? 0 Yes 0 No 0 N/A. If no, please explain: 3. Are the new site conditions (soils, topography, etc) consistent with what was reported by the soil scientist and/or Professional Engineer? ❑ Yes ❑ No 0 N/A. If no, please explain: 4. Is the proposed residuals management plan for the adequate and/or acceptable to the Division. 0 Yes 0 No 0 N/A. If no, please explain: 5. Are the proposed application rates for new sites (hydraulic or nutrient) acceptable? 0 Yes D No 0 N/A. If no, please explain: 6. Are the new treatment facilities or any new disposal sites located in a 100-year floodplain? 0 Yes 0 No 0 N/A. If yes, please attach a map showing areas of 100-year floodplain and please explain and recommend any mitigative measures/special conditions in Part IV: 7. Are there any buffer conflicts (new treatment facilities or new disposal sites)? Fj Yes or No. If yes, please attach a map showing conflict areas or attach any new maps you have received from the applicant to be incorporated into the permit: FORM: NDSRR 03/02 2 a f NON -DISC ,,ARGE REGIONAL WATr A QUALITY STAFF REPORT AND RECOMMENDATIONS RENEWAL AND MODIFICATIONAPPLICATIONS (use previous section for neiv or major modification systems) DESCRIPTION OF WASTES) AND FACILITIES Are there an appropriately certified ORCs for the facilities? Z Yes or ❑ No. Operator in Charge: Stan Bryson Certificate #:13180 Back- Operator in Charge: None Certificate #: 2. Is the design, maintenance and operation (e.g. adequate aeration, sludge wasting, sludge storage, effluent storage, etc) of the treatment facilities adequate for the type of waste and disposal system? ® Yes or 0 No. If no, please explain: 3. Are the site conditions (soils, topography, etc) maintained appropriately and adequately assimilating the waste? ® Yes or ❑ No. If no, please explain: 4. Is the residuals management plan for the facility adequate and/or acceptable to the Division? ® Yes or ❑ No. If no, please explain: 5. Are the existing application rates (hydraulic or nutrient) still acceptable? ❑ Yes or ❑ No. If no, please explain: 6. Are there any buffer conflicts (treatment facilities or disposal sites)? ❑ Yes or ® No. If yes, please attach a map showing conflict areas or attach any new maps you have received from the applicant to be incorporated into the permit: 7. Is the type and/or volume of waste(s) as written in the existing permit correct? ® Yes or ❑ No. If no, please explain: 8. Is the description of the facilities as written in the existing permit correct? ❑ Yes or ® No. If no, please explain: No description of RDP process in permit. System consists of an aerobic digestor, be press, sludge mixing pug mill with lime addition from silo, reator vessel, conveyor belts, and a concrete distribution pad. 9. Has a review of all self monitoring data been conducted? ® Yes or ❑ No. Please summarize any findings resulting from this review:. Facility monitors metals, nutrients, TCLP and pathogen and vector attraction reduction in accordance with permit and 40 CFR 503. 10. Check all that apply: ® No compliance issues; ❑ Notice(s) of violation within the last permit cycle; ❑ Current enforcement action(s) ❑ Currently under SOC; ❑ Currently under JOC; ❑ Currently under moratorium. If any items checked, please explain and attach any documents that may help clarify answer/comments (such as NOV, NOD etc): FORM: NDSRR 03/02 3 NON -DISCI RGE REGIONAL OVATE QUALITY STAFF REPORT AND RECOMMENDATIONS 11. Have all compliance dates/conditions in the existing permit, SOC, JOC, etc. been complied with? Yes or ❑ No. If no, please explain: 12. Are there any issues related to compliance/enforcement that should be resolved before issuing this permit? ® Yes or 0 No. If yes, please explain: dry storage of stabilized residuals needed. E VAL UA TION AND RECOMMENDATIONS 1. Provide any additional narrative regarding your review of the application.: 2. List any items that you would like NDPU to obtain through an additional information request. Make sure that you provide a reason for each item: 3. List specific Permit conditions that you recommend to be removed from the permit when issued. Make sure that you provide a reason for each condition: Condition 4. List specific special conditions or compliance schedules that you recommend to be included in the permit when issued. Make sure that you provide a reason for each special condition: 5. Recommendation: ❑ Hold, pending receipt and review of additional information by regional office; Hold, pending review of draft permit by regional office; ® Issue; ❑ Deny. If deny, please state reasons: 6. Signature of report preparer: FORM: NDSRR 03/02 4 NON-DIS( ARGE REGIONAL WAT rR QUALITY STAFF REPORT AND RECOMMEN ATIONS Signature of WQS egional supervisor:4��l 01 OF Date: ADDITIONAL REGIONAL STAFF REVIEW ITEMS FORM: NDSRR 03/02 �a sei gee serving Jackson Conn i � Chairman, J.C. Alexander James Cochran Wafer and Sewer Authority Webster Dillsboro Vice -Chairman, Mickey Luker Alvin Stiles Jackson County Sylva Jerry R. King E.recutive Director April 3, 2002 Attn: J.R. Joshi Division of Water Quality Non-nischarge Permitting Unit 1617 Mail Service Center Raleigh, NC 27669-1617 Subject: Residuals permit renewal and modification TWSA (WQ 0005763) Dear Mr. Joshi, Ann F. Cabe Sylva Keith Ward Jackson County Marion Jones C. J. Carter Sylva Western Carolina University As per our phone conversation of April 3, I have compiled the following: (1) Please find attached a check in the amount of $205.00 dollars made payable to NCDENR to cover the fee for modification of the permit. Tuckaseigee Water and Sewer Authority hereby requests that the permit be written for an annual sludge production of 250 dry tons. (2) I have included the annual sludge production totals and the distrubution and marketing summary for 2000 and 2001. (3) A materials handling overview addressing the information requested on page 7 of the permit renewal application along with an waste analysis report for the residuals that we have incorporated into an information leaflet to be given to all users of the residuals. and, (4) A letter from the Executive Director of the Authority designating signatory authority As we discussed on the phone, a cover for the pad where residuals are stored would be a great help in keeping the product dry and more easily worked with. We are currently obtaining estimates from contractors for budget purposes but we are also beginning to start the process of expanding the wastewater treatment facility. I feel it would be prudent if we finalized any expansion plans before committing funds to cover a pad that is in an area thay may be needed' for the expansion. 32 Asheville Hwy. Post Office Box 1051 Sylva, North Carolina 28779 828/586-5189 --a I., I hope this is the information you require. If you have questions or comments, please do not hesitate to contact me. I can be reached directly at 828-586-9318. Sincere Stan Bryson Wastewater Operations Superintendent Tuckaseigee Water & Sewer Authority �'i State of North Carolina - Department of Environment and Natural Resources Division of Water Quality Michael F. Easley, Governor William G. Ross Jr., Secretary Gregory J. Thorpe, Ph D., Acting Director 1 0 • As Muft CEIPWR NORTH CAROL ENVIRONMENT AN November 29, 2001 TUCASEIGEE WATER & SEWER AUTHORITY JERRY KING P O BOX 1051 SYLVA NC 28779 Subject: Acknowledgement of Application No. WQ0005763 Distribution of Residuals Solids Jackson County Dear Mr. King: The Non -Discharge Permitting Unit of the Division of Water Quality (Division) acknowledges receipt of your permit application and supporting materials on November 5, 2001. This application package has been assigned the number listed above. Your application package has been assigned to J R Joshi for a detailed review. The reviewer will contact you with a request for additional information if there are any questions concerning your submittal. If you have any questions, please contact J R Joshi at 919-733-5083 extension 363. If the reviewer is unavailable, you may leave a message on their voice mail, and they will respond promptly. PLEASE REFER TO THE ABOVE APPLICATION NUMBER WHEN MAKING INQUIRIES ON THIS PROJECT. Sincerely, Kim H. Colson, P.E. Supervisor, Non=Discharge Permitting Unit c: . sheville Regional Office, Water Quality Section Permit Application File WQ0005763 1617 Mail Service Center, Raleigh, North Carolina 27699-1617 Telephone 919-733-5083 FAX 919-715-6048 An Equal Opportunity Affirmative Action Employer 50% recycled / 10% post -consumer paper TABLE OF CONTENTS e C- j :� (1) Non -Discharge Permit Application Form W C �..; c� LL (2)(a) Materials Handling Overview n (b) Annual Distribution and Marketing Summary (c) Information sheet supplied to users (3)(a) TCLP Analysis (b) Pollutant and Nutrient Analysis (c) Fecal Coliform Analysis SECTION ONE NON -DISCHARGE PERMIT APPLICATION FORM State of North Carolina f Department of Environment, Health and 1.aL-ural Resources Division of Environmental Management hurl-i�is�itat�C rCillU fippllt dflUn corm (THIS FORM MAY BE PHOTOCOPIED FOR USE AS AN ORIGINAL) DISTRIBUTION OF RESIDUAL SOLIDS This application's intended for facilities which are to be regulated under 40 CFR Parr 503 I. GENERAL INFORMATION: ame of the municipality, corporation indiddual, etc. 1_ Applicant's came (please specify the n): titC,�0.�C.t 2. Print owners or sig g official's name and title (the person who is legally responsible for the facility and its compliance): 3. Mailing address: State: Zip: / City:—Eyj � /0 Telephone Number: 4. Application Date:% b [The permit processing fee should be as specified in 15A NCAC 2H .0205(c)(5).1 5. Fee Submitted: S lawn (bull:); 6. Specify bow these residuals will be distributed: sold or giver away in bags or other containers: home garden (bulk); _ other, _ ` n• In ,te :'; ?• if t,};e alternative for residual disposal consists of "Surface disposal" as defined under 40 CFR Part 503 pleaseonrcomplet in application titled "SURFACE DISPOSAL OF RESIDUAL SOLIDS. Please idena�; ,L , a surface impoundment or disposal thru landfilling. Explain: No S. Is the residual process facility also the generator? Yes; f !1 9. Latitude: U° ao r 59 Longitude: S 3� —of residual process facility te; local sjoverninent; 10. Specify whether the process facility is owned by: federal; private; sta 11. County where facility is located: c )oc- k Solt) II. PERMIT LN-FORI\IATION: i. Application No. (will be compieted by DEvl): • Specify whether project is: new; X— renewal*; modification 1nQ Signature and Seal not required for ' For renewals, complete all sections included in the application_ Engineer g renewals or if there is not any construction involved vni= th the subject projlL ed =� a result of a renewal or mcu-�Llcation to an xisting permit, list the existing permit 3. If this application is being submitt � and its ;=•,4z date number Pa FORM nKS 06l94 Page. 1 of 8 IIT. FACILITY INFORMATION (attach additional pages for additional ources of residuals): residuals are gencra,.e,2 cr prep: -ed: 2. Facility permit number: c ✓facility permit holder: r k) e-r- 3. Specify whether facility in Section III.1 is owned by: federal; private; state; local government; Iv 4. Specify facility design flow: . mgd; facility average daily flow: 5._ Type of residual storage:' Volume of residual storage: mad; \1 Length of residuals storage at facility: �30 days (the Division requires a minimum 30 days storage in units that are separate from treatment system, i.e. no/tJin clarifiers, aeration basins, etc.); Estimated volume of residuals: (dry tons/yr.); 5. If the residual process facility is not the same as the generator, please specify delivery frequency and quantity of residual to be processed: 6. Facility contact (person familiar with residuals preparation).- 7. Facility contact's telephone number: 8. Location of treatment facility: 11a-cn 01 State; County 9. Mailing address:' 10. Specify the source of the residuals: 7XI— treatment of domestic wastewater-, treatment of industrial wastewater; other (explain): Attach an explanation of either the treatment process, manufacturing process, or bow the waste is generated. Provide full and complete details of the entire process. 11 _ Does The facility whirh aenerateS the rAS:d',, 1S have a, 2^^�^-Pia This includes facilities which are classified as a "CIass I" facility (any publicly owned treatment works required, under 40 CFR 403.8, to have an approved. pretreatment program or any facility treating domestic sewage that is classified as "Class I" by the appropriate federal or State authority) RESIDUALS INFORMATION (attach additional pages for additional sources of residuals): 1. Information for Hazardous Waste (RCRA) Determination. The information requested on the limitations specified below pertain only to those residuals that are generated from a municipal wastewater treatment facility with industrial contribution or active pretreatment program and from any other treatment facility with wastewater sources that include industrial sources. a. Are any of the residuals covered by this application listed in 40 CFR 261-31-261.33? Yes, X No. If Yes, list the number(s): b. Do the residuals exhibit any of the four characteristics defined by 40 CFR 261.21-261.24? Yes; No. Attach laboratory results for the Toxicity Characteristic Leaching Procedure Analyses, Reactivity, Ignitability, and Corrosivity for each residual. FORM: DRS 06/94 Paec 2 of 8 t Note: If the following constituent levels (as determined by the Toxicity Characteristic Leaching Procedure Analyses) are exceeded in the residuals or if the pH of the residual is not within the range listed below, the residual is by definition a Hazardous waste. Chemical analyses must be made to Minimum Detection Levels. PPM PPM Arsenic 5.0 Barium 100.0 Benzene 0.5 Cadmium 1.0 Carbon tetrachloride 0.5 Chlordane 0.03 Chlorobenzene 100.0 Chloroform 6.0 Chromium 5.0 o-Cresol 200.0 m-Cresol 200.0 p-Cresol 200.0 Cresol 200.0 2,4-D 10.0 1,4-Dichlorobenzene 7.5 1,2-Dichloroethane 0.5 1,1-Dichloroethylene 0.7 2,4-Dinitrotoluene 0.13 Endrin 0.02 Heptachlor (and its hydroxide) 0.008 Hexachlorobenzene 0.13 Hexachloro-1,3-butadiene 0.5 Hexachloroethane 3.0 Lead 5.0 Lindane 0.4 Mercury 02 Niethoxychlor 10.0 Methyl ethyl ketone 200.0 Nitrobenzene 2.0 Pentachlorophenol 100.0 Pyridine 5.0 Selenium 1.0 Silver 5.0 Tetrachloroethylene 0.7 Toxaphene 0.5 Trichloroethylene 0.5 2,4,5-Trichlorophenol 400.0 2,4,6-Trichlorophenol 2.0 2,4,5-TP (Silvex) 1.0 Vinyl chloride 02 pH (2:1 vol./wt.): >2.0 s.u. - <12.5 s.u. NOTE: IF ?,_VY OF THE RESIDUALS MEET THE DEFINITIONS OF A HAZARDOUS WASTE, AS NOTED IN EITHER "A" OR "B" ABOVE, A PERMIT CANNOT BE ISSUED FOR THAT MATERIAL AND IT SHOULD NOT BE INCLUDED AS PART OF THIS APPLICATION. 1 Tt;ir W n1„y:� .T,�,�r ho CoLn nrPII P.T C1Ve enough r the 2. For each residual, pieasc a%aCh a Cvu:piete chemical analysis of the y:ate a . r _� - --- �- �_ i If to completely characterize the residual and must be based upon a review of the process that generates the material. the facility that will generate the residual is not yet in operation, the characterization must be based on similar existing facilities and projection based on the type of facility. The m analysis must include a min of the following parameters and any other known and suspected contaminants that are tributary to the system. Arsenic Molybdenum Calcium Phosphorus Cadmium Nickel Magnesium Potassium Chromium Selenium Nitrate -Nitrite Nitrogen Sodium Copper Zinc % Total Solids TKN Lead Aluminum pH Mercury Ammonia -Nitrogen Plant Available Nitrogen (by calculation) Page 3 of 8 FORM: DRS 06194 3. Wastewater residuals cannot be sold or given away if -the concentration of any pollutant in the residuals exceeds the ceiling concentrations specified in the table below. Specify the pollutant concentration of these residuals (attach lab analysis): Pollutant Pollutant Ceiling Concentration (mg/kg) Pollutant Concentration (mglhg) Dry Weight Basis Dry Weight Basis Arsenic 75 0 Cadmium 85 Chromium 3000 Copper 4300 Lead 840 Mercur • 57 e Molybdenum 75 Nickel 420 v® Selenium 100 Zinc 7500 4. Provide, all applicable pilot studies and any bench scale tests performed on each residual source and the results, including the approximate fertilizer equivalent 5. Wastewater residuals can't be sold or given away in bags or other containers for application to the land unless one of the following options is satisfied. Specify either A or B. Please be advised, if the residuals'are to be sold or given away in bulk for application to lawn or home garden then Option A is the only option. A . The pollutant concentration of the residuals must be less than Pollutant Monthly Average Concentrations listed in the table below. Pollutant vu I.t .(7•`'S.LQ `{�' �IIIIc��lil Y%1v7� t� DryVeight Basis ■ i vii�ii4 nT� /ln/"nr�lr T. `. r. � .acu `.vuwuu2iuvit (mg/kg) Dry Weight Basis (mg/kg) Arsenicf7 41 Cadmium 39 . Chromium 1200 Copper 1500 Lead 300 17, Mercury 17 Nickel 420 Selenium 36 � Zinc 2 800 B . The product of the concentration of each pollutant in the residual and the annual whole residual application rate for the residual shall not cause the Annual Pollutant Loading Rate to be exceeded. In order for the Annual Whole Residual Application Rate (AWRAR) to be calculated the Annual Pollutant Loading Rate (APLR) is divided by the pollutant concentration. (PC) times 0.001 (a conversion factor) as follows: AWRAR = APLR PC * 0.001 FORIM: DRS 06194 Paae 4 of 8 j I Pollutant Pollutant Concentration Dry Wei2lit Basis (m�/kal Annual Pollutant Loading Rates (APLR) -k-a/hectare Annual Whole Residual Application Rate (AWRAR) kg/hectare Arsenic 2.0 Cadmium 1.9 Chromium 150 Copper 75 Lead 15 Mercury 0.85 Nickel 21 Selenium 5.0 Zinc 140 The AWRAR for the residual is the lowest AWRAR calculated. This is the maximum rate at which the subject residual can be applied (to convert kg/hectare to lbs/acre multiply by 0.8924). Please specify kg/hectare or lbs/acre: V . PATHOGEN AND VECTOR ATTRACTION REDUCTION INFORMATION (attach additional pages for additional sources of residuals): 1. In order for the residuals to be Class A, in accordance with the pathogen requirements in 40 CFR 503.32(a), either Past a or Pan b Mi one of the options in Part c must be completed (please submit all lab analysis, test results and calculations): a. A Fecal coliform density less than 1000 Most Probable Number per gram of total dry solids, or b. A Salmonella sp. density less than 3 Most Probable Number per 4 grams of total dry solids. 5& c. In addition to Part a or Pan b being met, one of the following alternatives must also be completed. Please specify 1, 2, 3, 4. 5a, 5b, 5c, 5d, 5e, 5f: 5g or 6 below being met: 1. time/temRerature - an increased residuals temperature should be maintained for a prescribed period of time, in accordance with the following guidelines. The results (D) shall be the amount of time, in days, that the residuals shall remain at the given temperature: Total Solids Temperature (t) Minimum Time Equkion Notes No heating of small > or = 7110 > or = 500 C > or = 20 minutes D = 1111,700,000 particles by warmed 100.14 t gases or immiscible liquid. > or = 7% > or = 50o C > or = 15 seconds D = 13l .700.000 Small particles heated by 100.14 t warmed cy gases or immiscible liquid. < 7% ; or = 500 C > or=15 seconds D = 131,700,000 to 100.14 t < 30 minutes < 7% > or = 500 C >or = 30 minutes D = 070 .1 100�14 t FORM: DRS 06/94 Pale 5 of 8 2_ 2_1k?line. treatment - the pH of the residuals is raised to greater than 12 for at least 72 hours. During this time, the temperature of the residuals should be greater than 520 C for at least 12 hours. In addition, after the 72 hou.- period; the residuals are to be air dried to at least 50% total solids. 3. prior testing for Enteric VjruS/—ViablQ Helminth Ova - the residuals are analyzed for the presence of enteric viruses (Plaque-foiming units) [pfu] and viable helminth ova. If the residuals are analyzed before the pathogen reduction process and found to bave densities of enteric virus <1 pfu/4 grams of total solids and viable helmintb ova <1/42 total solids, the residuals are Class A with respect to enteric virus and viable belminth ova until the next monitoring episode. If the residuals are analyzed before.the pathogen reduction process and found to have densities of enteric virus > or = 1 pfu/4 g total solids or viable helminth ova > or = 1/4 g total solids, and tested again after processing and found to meet the enteric virus and viable helminth ova levels listed under "4" below, then the processed residuals will be Class A with respect to enteric viruses and viable helminth ova when the operating parameters for the pathogen reduction process are monitored and shown to be consistent with the values or ranges of values documented.. 4. no pjjor testing for Enteric Vinis[Viable Helm Dth (ova - if the residuals are not analyzed before pathogen reduction processing for enteric viruses and viable hehninth ova, the density of enteric viruses must be less than 1 pfu/4 g of total dry solids and the density of viable helminth ova must be less than 1/4 g of total dry solids, or the residuals must be treated by a "Process to Further Reduce Pathogens" or a "Process to Further Reduce Pathogens" equivalent . process. S. 7be "Processes to Further Reduce Pathogens" (PFRP) are described as follows: a. imp s in a - using either the -within -vessel or static aerated pile composting methods, the temperature of the residuals are raised to 550 C or higher for three days. Using the windrow composting method, the residuals are raised to 550 C or higher for fifteen days. During the high temperature period, there will be a minimum of five turnings of the windrow. b. Heat Drying - residuals are dried by direct or indirect contact with hot gases to reduce the moisture content of the residuals to 10% or lower. Either the temperature of the gas in contact with the residuals exceeds 800 C or the wet bulb temperature of the gas in contact with the residuals, when the residuals leave the dryer, exceeds 800 C. c. Heat Treatment - liquid residuals are heated to a temperature of 1800 C or higher for thirty minutes. d. Thermoohilic Aerobic Digestion - 1im,;rt dL'a.S are a�iwu.0 resi t gmatea 'With .�.-....., u 4i� or oxygen in maintain aembiC conciruonr at residence times of ten days at temperatures of 55o C to 600 C. e. Beta Ray Irradiation - residuals are irradiated with beta rays from an accelerator at dosages of at least 1.0 megarad at room temperature (ca. 200 Q. f. Gamma Ray Irradiation - residuals are irradiated with gamma rays from certain isotopes such as 60Co and 137Ce, at dosages of at least 1.0 megarad at room temperature (ca. 200 Q. 0Pasteurization - the temperature of the residuals is maintained at 700 C or higher for at least thirty minutes. 0 6. The residuals shall be treated in a process that is equivalent to a "Processes to Further Reduce Pathogens" (PFRP), as determined by the permitting authority based on evaluations of the recommendations provided by the Pathogen Equivalency Committee. 2. When residuals are to be sold or given away, one of the following vector attraction reduction requirements (a, b, c, d, e, f, g, or h) described below must be met. Specify the letter of the vector attraction reduction requirement that has been met (submit lab results, test results and calculations). Any variation of the below must be described in full detail and attached. a.... Aerobic or Anaerobic Dia _scion - The mass of volatile solids are reduced by at least 38%. Volatile solids reduction is measured between the residuals, prior to stabilization, and the residuals ready for use or disposal. This criterion should be readily met by properly designed and operated anaerobic digestors, but not as readily met by aerobic digestors. Treatment facilities with aerobic digestors may need to meet the vector attraction reduction requirement through 19c or 19d. . FORM: DRS 06/94 Paae 6 of 8 b. Anaerobic D�?estion - If 38% volatile solids reduction cannot be achieved, vector attraction reduction can be demonstrated y further digesting a portion of the previously digested residuals in a bench scale unit for an additional 40 days at 302 C to 37° C_ If, at the end of the 40 days, the volatile solids are reduced by Iess than 179c, vector attraction reduction is achieved. c. Aerobic igue�,ion - If 38% volatile solids reduction cannot be achieved, vector attraction reduction can be demonstrated by further digesting a portion of the previously digested residuals that have a solids content of 290 or less in a bench scale unit for an additional 30 days at 201 C. If, at the end of the 30 days, the volatile solids are reduced by less than 15%, vector attraction reduction is achieved. d- Aerobic Digestion - The specific oxygen uptake rate (SOUR) shall be equal to or less than 1.5 milligrams of oxygen per hour per gram of total dry solids at 20" C. e. Aer is Proce .ses - The temperature of the residuals for at least 14 days shall be greater than 400 C. During this time, the avenue temperature shall be greater than 451 C. f. Ikaline Stabilization - The pH of the residuals is raised to 12 or higher by alkali addition and, without the addition of more alkali, remains at 12 or higher for 2 hours and then at 11.5 or higher for an additional 22 hours. g_ Drvino (stabilized Solids) - The total solids of residuals that do not contain unstabilized solids, and which are generated in a primary %wastewater treatment process, shall be equal to or greater than 75%. Blending with other materials is not allowed to achieve the total solids percentage. h. Drying (unsia ili solids) - The total solids of residuals that contains unstabilized solids, and which are venerated m a primary wastewater treatment process, shall be equal to or greater than 9017c. Blending with other materials is not allowed to achieve the total solids percentage. VI. GENERAL INFORMATION: 1. Please provide a brief narrative concerning materials handling, including the following: a. How will the materials will be handled and transported from where the residuals were produced to where it will be treated? b. Where will the residuals be stored until processed? c. How will leac_ate collection be handled? d- What will be :he duration of treatment? e. Where will the final product be stored? f. How lone will me final product be stored before being distributed? g. How will the final product be distributed (packaging)? 2. Please attach a marketability statement detailing destinations and approximate amounts of the final product to be distributed. 3. Please provide eitbl a label which shall be affixed to the bagged processed residual or an information sheet which shall be provided to the person who receives the processed residual. The label or information sheet shall contain, at a minimum, the following information: a. The :came and address of the person who prepared the residual that is sold or given away in a bag or other container for application to the land. b. A statement that application of the residual to the land is prohibited except in accordance with the histrucdons on the label or information sheet_ c. A statement that the residuals shall not be applied to any site that is flooded, frozen or snow-covered. d A statement that adequate procedures shall be provided to prevent surface runoff from carrying any dispossd or stored residuals into any surface waters. e. Information on all applicable buffers including a 10 foot buffer between application site and any public or private water supply source (including wells) and any stream, lake, river, or natural drainage way. f. The Annual' hole Residual Application Rate (AWRAR) for the residual that does not cause any of the annual pollutant loading rates to be exceeded (if necessary). FORM: DRS 06,94 Paae7 of Name and Complete Address of Engineering Finn: City: Telephone Number: Professional Engineer's Certification: State: Zip: I, , attest that this application for has been reviewed by me and is accurate and complete to the best of my knowledge. I further attest that to the best of my knowledge: the proposed design has been prepared in accordance with the applicable regulations. Although certain portions of t..5is submittal package may have been developed by other professionals, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. North Carolina Professional Engineer's Seal, Signature, and Date: Applicant's Certification: I, ©Y-) attest that this application for T c t� r' r r has been reviewed by me and is accurate and complete to the b st of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting information and attachments are not included, this application package will be returned to meYs inc0mDlete/7 S Date _ 2 /0 THE COMPLETED APPLICATION PACKAGE, INCLUDING ALL SUPPORTLNG INFORMATION AND MATERIALS, SHOULD BE SENT TO THE FOLLOWING ADDRESS: NORTH CAROLINA DIVISION OF ENVIRONMENTAL MANAGEMENT WATER QUALITY SECTION PERMITS AND ENGINEERING UNIT POST OFFICE BOX 29535 RALEIGH, NORTH CAROLINA 27626-0535 TELEPHONE NUMBER: (919) 733-5083 FORM: DRS 06/94 Pagc 8 of 8 SECTION TWO (a) MATERIALS HANDLING OVERVIEW (b) ANNUAL DISTRIBUTION AND MARKETING SUMMARY (c) INFORMATION SHEET SUPPLIED TO USERS Materials Handling Overview Tuckaseigee Water & Sewer Authority Residuals are being generated at the following locations: TWSA Plant #1(NC0039578) 97.48 dry tons* TWSA Plant 92(NC0020214) 29.82 dry tons* TWSA Plant #3(NC0063321) 19.04 dry tons* *residuals production for the year 2000 All residuals generated at TWSA Plants 2 & 3 were trucked in liquid form to the digestor at Plant 41 where they were combined with the residuals generated at Plant #1. This residual source was then sampled for TCLP and then dewatered and treated with lime to meet the requirements of the permit and 503 regulations. Residuals thus treated are then stored on a concrete pad at the facility. Leachate and runoff from this pad are returned to the head of the plant for treatment. The length of time residuals are stored varies due to the time of year. Farmers using the product typically use more at the start of the growing season and in the fall after hay has been harvested. The product is usually distributed in bulk in user supplied spreader trucks. The annual distribution and marketing summary for the year 2000 is attached with the application for your review. TWSA PLANT # I ANNUAL DISTRIBUTION AND NiA.RKETING SUMMARY 2000 DART A VOLUME IN DRY TONS MONTH ADMENDMENT/ BULKING AGENT IN RESIDUAL IN PRODUCT OUT Janua 0 Februa 0 March 0 April 15.74 10.67 26.41 Ma 0 June 0 Jul 0 August 0 September 18.56 14.76 33.32 October 3.85 2.83 6.68 November 0 December 0 Annual Dry Tonsl 38.151 28.26 66.41 PART R RECIPIENT INFORMATION DATE NAMES VOLUME wet tons INTENDED USE 2/23/00 John Frady 1 lawn & garden 311/00 Tim Crowe 3 pasture 3111/00 smoky Mtn_ Golf Club 40 golf course 3/23/00 Tim Crowe 1 pasture 3131100 Jim Rhineheart 10 pasture 4/1/00 Jim Rhineheart 40 pasture 7/26/00 Dee Mull 14 hn field Total109 ton x 54% solids= 58.9 dry tons ly .,. �,.". .3.� .NCDAA + 'I' �43"QOPaR•e�ci' h, �NG, 2.7.G47. C�6S i9���) G�S�; �Re oc�=Np r.onomic�Di�tsroti ;C'r,ee{r;,l?o�til:�t:?lel :1 1 l �3�.- ..1 n, La�^;1•:a.(I ,,r-..., „rI,�,I:� :,.15. ,WO-8528�;'W.' Groiuer Tuckaseigee \rater & Sewer Copies To: PO Box 1051 Sylva, NC 28779 W6, f'1Waste Analysis Rephort 5/ 9/01 Jackson County Sam le 1nfo. ;i:,,. :Resu :ts;;(t arts,' et nii11'ioti't•ttn!'ess;o'fhl�lltseno,tbd) `' ,:,.:. ,I.a.U,q.p,ltp , Sample ID: N P K Ca M S Fe A171 Zn ell B No G/ G' T1i'SA-; ;;::• Tolal .15634 5843 1799 201847 2712 2355 4524 229 205 136 13.8 1N •N I,? -Ste Corte: -NI14 S NO3 Na Ni ed Pb Al Se _ Li pH SS G`N Dri195 CCE%' A1,60ons) 483 3,65 0.65 6,82 11,64 51.62 75.00 2.30 Description: OR•N Municipal (Lime Scab.) Urea rY in d>r ir: ., i ,1,.11.,.'�. 'J•;. vACy ,• Re:Cptmendatlons ittifriellts Avai(alii` f rsf: ;w iu�t'Gilsys Zlir Isle.rtep lbs/torr Grrsls .::; .. ,.r.:.,.. , . ar + ,[ ., irli: ri ,,, _. laa,, :.1bs/tort:, , ,, ,<t h Pr.l..1 �., i , ... t s.[ .,<c; . rrret . ,: t.. ... n. .,:.. .,; i.. :. ,... �.. r }' -.+: nl �,. rrv.E. ,. ,.i +i5 ":ei I}•.t f•t'+. 4YI :.:...-'1 I €,'; ,x I4Ji {tl -.€ I Y 7 � Y X a i[ ,)r }�: i. I ffi � .i r . �.> ,J 15 A �Ircnhori lelltorl , ._„ N,,.•:r,P._0. , ,:1�, 0.,>..,.r.:6'n+ �. .r•1 ,� ,.:5 i. nr..• e l :�hr .�,.;f n. ,.,r, r� :., I ,,,h(o,r... it � A '.,.'�:.3 7 , S � _`?, d sy,€}74 L, S U, �., , /� a�. �G/>x.. �.11; i2't7�,ffp�� r S f.:l r ) X r= Nr Grl =PG Al. Se Li ,?) i a 1 !.: :- '... .ra C Jdvr(1ry :/�/. ,(1 .. ,. I .•. ...: J :. :, ,i H',-..}. .)' 11 ,, ... ..�, �,.:, 4.1 '1'an 7f.: t.. ... �.I,. .. i�':it": .-1 >...1 A Vi t(d:., b � �, .. (,:: 9,IYi,:n ll � :... ,.,..: '>..[ ., :,I... .. {. I e .+,. rc .,. i , Z.I.r. I �... I } I 'fr ., . 1e.� € ,,•::..'� n .L,I ,.--=r t.. 1:. 1 lirolld asl. :., > -4. , � ,Y.,8., .:.., a,1:.,. � � ,,, a , J �-O.111� x€a:�;;.tlpi $}; �, r 0] :/I'1,Y. �,,ti } u � S 3 5€ � }I� �,I� ,. : .:�:IFa ..:f 1 .I t d'; I G ' (' , „ p•E 0� 4+•slhiT },r a:�+i ;�'010] , � t +,; I . .',, . .., . � ...� .., ,,�1' ,::. ,r ,h:r€''0 [ �I } .€,�:�t'1+ ... •... , , ,; it$.. I [, ,���. ct�,,7 . ar, ,;±1,� }s � r..�'$ rl.,r�. a[ [M�1,. ;, _ k:•F :•..1 f !r t, ,.A Y I i.! Iyi I,i 1 Yi's .l IZ, f f !'� r I [} � I '}if91, r}le.... � , , /s , YI II i2,. k 1 1 (...%: I ...... '.1 (.,-.\.. ".i.:. thlivr,�.. r�:l i.:...?: ....,€, .'...91} ,:,. [!.'..f v..4l,ll i+.1 ,��tpY.l !i ((..--•V.:. .. . .. : '.., •. -.. 'i.. .i.. II✓'II I ,Y: I.r ..`, -if- 1 .fv. .1-� •��i`I,1'. .... fj.J„ ',. 11 1'1C;11'ilalC; ll VIIIIVI Vita. iA"Ill'II IICU.VI'i111Ll11'i\'{I1'llGiil l'll_(JI'IVIIISIiVIII.Up•ill Jll lV �i41:(I alC.l ,I1C IVC.U`IV-IIII..hG' ;rV,II,111,{V,;111 fJilll511414:1YII i 1 b b. f. 1 I.[1Y 1. 4 'A?,L-. [ s[r1x <P<. � l.l, 1 t r5. -.♦ tyli M1l. cL1-1 -VIr,1,IV:,}?tIJIV,;1.Gt lNI It l}i1t(,V ll II111�11[,,;IIc.Af,1,111LI11 b , he lon oI'ngriciill`urHl Ilene. s y[ €..,,. 1 fil al air"r ? _—.s , "sa i. , l 1 r.8,s 1 +f: These municipal Nvaste residuals were prepared By: Tuckaseigee Water and Sewer Authority 1871 North River Rd. Sylva. NC 28779 ph; 929-586-9318 eared under authority of *North Carolina Dept, of Environment, Health and Natural Resources, (Division of Water Quality) Permit -9 WQ0005763 Application of this product to the land is prohibited except in accordance with the instnctions on this information sheet. (1) A minimum ten foot. buffer between application site and any public or private water supply (including wells) and any stream, lake, or river. (2) Product shall not be applied to any site that. is flooded, frozen or snow covered. (3) Adequate procedures shall be provided to prevent surface runoff from carrying any disposed or stored residuals into any surface waters. (4� Soil tests are recommended to identify optimum application rates. SECTION THREE (a) TCLP ANALYSIS (b) POLLUTANT AND NUTRIENT ANALYSIS (c) FECAL COLIFORM ANALYSIS �FaceAnalytical www.pacelabs.com aseigee Water & Sewer Auth PU Box 1051 Sylva, NC 28779 Lab Project Number: 9319594 Client Project ID: TCLP Pace Analytical Services, Inc. 54 Ravenscroft Drive Asheville, NC 28801 Phone: 826.254.7176 Fax: 828.254.4618 Attn: Mr. Stan Bryson Phone: (828)586-9318 Solid results are reported on a dry weight basis Lab Sample c�':..�93838647 Project Sample Number: 9319594 001 Date Collected: 04/11/01 00:00 Client Sam 6-3D: RAW SLUDGE Matrix: Soil Date Received: 04/11/01 14:00 Parameters Results Units PRL Analyzed Analyst CAS# Ftnote Limit Metals RCRA Metals, ICP, TCLP Leach. Arsenic Barium Cadmium Chromium Lead lenium Iver Date Digested Mercury, CVAAS. TCLP Leachate Date Digested Mercury, CVAAS. TCLP Leachate Mercury Wet Chemistry Percent Moisture Percent Moisture Paint Filter Liquids Test Free Liquids Date: 05/03/01 Method: EPA 6010 Prep Method: EPA 3010 ND mg/l 0.50 04/18/01 TRW 7440-38-2 5.2 mg/l 0.10 04/18/01 TRW 7440-39-3_ ND mg/l 0.010 04/18/01 TRW 7440-43-9 ND mg/l 0.020 04/18/01 TRW 7440-47-3 ND mg/l 0.10 04/18/01 TRW 7439-92-1 ND mg/l 0.10 04/18/01 TRW 7782-49-2 ND mg/l 0.050 04/18/01 TRW 7440-22-4 04/13/01 Method: EPA 7470 Prep Method: EPA 1311 04/13/O1 Method: EPA 7470 Prep Method: EPA 7470 ND mg/l 0.00020 04/19/01 TRW 7439-97-6 Method: % Moisture 79.3 X Method: EPA 9095 ND ml/5min 1.0 04/13/01 AAB Prep Method: EPA 9095 04/12/01 WWB Laboratory Certification IDs REPORT OF LABORATORY ANALYSIS NC Wastewater 40 NC Drinking Water 37712 This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc. Page: 1 Laboratory Certification IDs TN Drinking Water 02980 SC Environmental 99030 ace Analyticafu www.pacelabs.com Lab Project Number: 9319594 Client Project ID: TCLP PARAMETER FOOTNOTES ND Not Detected NC Not Calculable PRL Pace Reporting Limit Date: 05/03/01 Laboratory Certification IDs REPORT OF LABORATORY ANALYSIS NO Wastewater 40 NO Drinking Water 37712 This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc. Pace Analytical Services, Inc. 54 Ravenscroft Drive Asheville, NC 28801 Phone: 828.254.7176 Fax.- 828.254.4618 Page: 2 Laboratory Certification IDs TN Drinking Water 02980 SC Environmental 99030 ace Analytical m www.pacelabs.com Tuckaseigee Water & Sewer SyLva, NC 28779 Attn: Mr. Stan Bryson Solid results are reported on a dry weight basis Pace Analytical Services, Inc. 9800 KinceyAvenue, Suite 100 Nuntersville, NC 28078 Phone: 704.875.9092 Fax., 704.875.9091 Lab Project Number: 9222096 Client Project ID: Tuckaseegee W&S/9319594 Lab Sample No: 93838647 Project Sample Number: 9222096-001 Date Collected: 04/11/01 00:00 Client Sample ID: RAW SLUDGE Matrix: Other Date Received: 04/11/01 14:00 Parameters Results Units PRL Dilution Analyzed Analyst CAS# Ftnote Limit Metals Volatile Organics, TCLP Leach. Date Leached GC Volatiles Pesticides, TCLP Leachate Chlordane (Technical) Endrin Heptachlor Heptachlor epoxide gamma-BHC (Lindane) Methoxychlor Toxaphene Decachlorobiphenyl (S) Tetrachloro-rn-xylene (S) Date Extracted Acid Herbicides, TCLP Leachate 2,4-D 214,5-TP (Silvex) 2,4-DCPA (S) Date Extracted GC/MS Volatiles Volatile Organics, TCLP Leach. Vinyl chloride Date: 04/24/01 Method: EPA 8260 Prep Method: EPA 1311 0.00 1.0 04/17/01 LYS Method: EPA 8081 Prep Method: EPA 3510 ND mg/L 0.00050 1.0 04/16/01 TSG 57-74-9 ND mg/L 0.00050 1.0 04/16/01 TSG 72-20-8 ND mg/L 0.00050 1.0 04/16/01 TSG 76-44-8 ND mg/L 0.00050 1.0 04/16/01 TSG 1024-57-3 ND mg/L 0.00050 1.0 04/16/01 TSG 58-89-9 ND mg/L 0.00050 1.0 04/16/01 TSG 72-43-5 ND mg/l 0.00050 1.0 04/16/01 TSG 8001-35-2 60 % 1.0 04/16/01 TSG 2051-24-3 55 % 1.0 04/16/01 TSG 877-09-8 04/14/01 Method: EPA 8151 Prep Method: EPA 3510 ND ma/l 2.0 2.0 04/20/01 TSG 94-75-7 ND mg/L 0.20 2.0 04/20/01 TSG 93-rz-1 122 % 1.0 04/20/01 TSG 19719-28-9 04/17/01 Method: EPA 8260 Prep Method: EPA 8260 ND mg/L 0.020 1.0 04/18/01 02:23 RPJ 75-01-4 Page: 1 I- aboratory Certification IDs Laboratory Certification IDs NC Wastewater 12 REPORT OF LABORATORY ANALYSIS KY Drinking Water 90090 NC Drinking Water 37706 This report shall not be reproduced, except in full, VA Drinking Water 213 SC 99006 without the written consent of Pace Analytical Services, Inc. FL NELAP E87627 Pace Analytical Services, Inc. ?A naI�in�ITM1 9800 Kincey Avenue, Suite 100 1 l� Huntersville, NC 28078 Phone: 704.875.9092 www. pacelabs. cam Fax: 704.875.9091 Lab Project Number: 9222096 Client Project ID: Tuckaseegee W&S/9319594 Lab Sample No: 93838647 Project Sample Number: 9222096-001 Date Collected: 04/11/01 00:00 Client Sample ID: RAW SLUDGE Matrix: other Date Received: 04/11/01 14:00 Parameters Results Units PRL Dilution Analyzed Analyst CAS# Ftnote Limit 1,1-Dichloroethene ND mg/l 0.020 1.0 04/18/01 02:23 RPJ 75-35-4 2-Butanone (MEK) ND mg/l 0.40 1.0 04/18/01 02:23 RPJ 78-93-3 Chloroform ND mg/L 0.020 1.0 04/18/01 02:23 RPJ 67-66-3 1,2-Dichloroethane ND mg/l 0.020 1.0 04/18/01 02:23 RPJ 107-06-2 Carbon tetrachloride ND mg/L 0.020 1.0 04/18/01 02:23 RPJ 56-23-5 Benzene ND mg/l 0.020 1.0 04/18/01 02:23 RPJ 71-43-2 Trichloroethene ND mg/l 0.020 1.0 04/18/01 02:23 RPJ 79-01-6 TetrachLoroethene No,,' mg/L 0.020 1.0 04/18/01 02:23 RPJ 127-18-4 Chlorobenzene ND mg/L 0.020 1.0 04/18/01 02:23 RPJ 108-90-7 Dibromofluoromethane (S) 109 % 1.0 04/18/01 02:23 RPJ 1,2-Dichloroethane-d4 (S) 113 % 1.0 04/18/01 02:23 RPJ 17060-07-0 Toluene-d8 (S) 100 % 1.0 04/18/01 02:23 RPJ 2037-26-5 4-Bromofluorobenzene (S) 89 % 1.0 04/18/01 02:23 RPJ 460-00-4 Dioxin, High Resolution Semivolatile Organics, TCLP Method: EPA 8270 Prep Method: EPA 3510 Pyridine ND'V- mg/l 0.50 1.0. 04/17/01 18:55 YLJ 110-86-1 1,4-Dichlorobenzene ND mg/l 0.75 1.0 04/17/01 18:55 YLJ 106-46-7 2-Methylphenol (o-Cresol) ND mg/t 20. 1.0 04/17/01 18:55 YLJ 95-48-7 HexachLoroethane ND ✓ mg/l 0.30 1.0 04/17/01 18:55 YLJ 67-72-1 3&4-Methylphenol ND mg/t 200 10-0 04/17/01 18:55 YLJ Nitrobenzene ND✓ mg/l 0.20 1.0 04/17/01 18:55 YLJ 98-95-3 Hexachloro-1,3-butadiene ND•" mg/l 0.050 1.0 04/17/01 18:55 YLJ 87-68-3 2,4,6-TrichlorophenoL ND mg/L 0.20 1.0 04/17/01 18:55 YLJ 88-06-2 2,4,5-Trichlorophenol ND -/ mg/L 40. 1-0 04/17/01 18:55 YLJ 95-95-4 2.4-Dinitrotoluene ND- mg/L 0.013 1.0 04/17/01 18:55 YLJ 121-14-2 Hexachtorobenzene ND✓ mg/'l 0.013 1.0 04/i7/0i 18:55 YLJ 118-74-1 PentachlorophenoL ND✓ mg/l 10. 1.0 04/17/01 18:55 YLJ 87-86-5 Nitrobenzene-d5 (S) 59 % 1.0 04/17/01 18:55 YLJ 4165-60-0 2-Fluorobiphenyl (S) 56 % 1.0 04/17/01 18:55 YLJ 321-60-8 Terphenyl-dl4 (S) 73 % 1.0 04/17/01 18:55 YLJ 1718-51-0 Phenol-d6 (S) 19 % 1.0 04/17/01 18:55 YLJ 13127-88-3 2-FluorophenoL (S) 28 % 1.0 04/17/01 18:55 YLJ 367-12-4 2,4,6-Tribromophenol (S) 73 % 1.0 04/17/01 18:55 YLJ 118-79-6 Date Extracted 04/14/01 Date: 04/24/01 Page: 2 '-aboratory Certification IDs REPORT OF LABORATORY ANALYSIS Laboratory Certification IN . NC Wastewater 12 KY Drinking Water 90090 NC Drinking Water 37706 This report shall not be reproduced, except in full, VA Drinking Water 213 Sc 99006 without the written consent of Pace Analytical Services, Inc. FL NELAP E87627 icalTM aceAnalyt www. pacelabs. com PARAMETER FOOTNOTES ND Not Detected NC Not Calculable PRL Pace Reporting Limit (S) Surrogate Date: 04/24/01 Pace Analytical Services, Inc. 9800 Kincey Avenue. Suite 100 Huntersville, NC 28078 Phone. 704.875.9092 Fax: 704.875.9091 Lab Project Number: 9222096 Client Project ID: Tuckaseegee N&S/9319594 Page: 3 '_aboratory Certification IN REPORT OF LABORATORY ANALYSIS Laboratory Certification INNC Wastewater 12 KY Drinking Water 90090 NC Drinking Water 37706 This report shall not be reproduced, except in full, VA Drinking Water 213 SC 99006 without the written consent of Pace Analytical Services, Inc. FL NELAP E87627 Pace" Analytical The Right Chet, y, The Right Solution® CHAIN -OF' -CUSTODY / Analytical Request Document The Chain-c stody is a LEGAL DOCUMENT. All relevant fields must be completed accure 567631 Required Client Information: Section A Required Client Information: Section B Page: Of To Be Completed by Pace Analytical and Client Section C Com ' To: �`' Iw Quote Reference: �i / (f'l 3 Client Information Check uote/contract Addr Invoice To: Requested Due Date: 'TAT: Project Manager: • Turn around times less than 14 days subject to Project H: laboratory and contractual obligations and may result in a Rush Turnaround Surcharge. P Jett Name: Profile #: Turn Around Time (TAT) in calendar days. Phone ti ax ` (?13 Project Number: Requested Analysis / Section D Required Client Information: Valid Matrix Codes p p Preservatives MATRIX CODE p� C S A IVI P L C I D 0 LLER VOLT F H 00 - � c Z . One character per box. AIR WIPE AR O 0 2 = O w (A—Z, 0-9 / .—� TISSUE TS Q 0 O OZ (� Oca cb !_ Sample IDS MUST BE UNIQUE OTHER OT mm / dd / yy hh: mm a/p D _ _ = Z Z 1\ Remarks / Lab ID V • - a t <an+. ,.f.#'. r.� : r/iF*� ST 6 s sF r' �.... +KS' . -h+ 'PF 'R[-A Y i..^Yt m .•iT k v G L A a»sf Isis 3 _ �'F Temp in °C: Received on ICE: Y / N Sealed Cooler: Y / N Samples Intact: Y / N Additional Comments: of SAMPLER: PRIN , S PLER: DATE Sign M / D / YY) _ SIGNATURF,4 SEE REVERSE SIDE FOR INSTRU // Pace Analytical Services, Inc. /ForVCOCOI.XLS 12/99 nQlrinlal v ace Analytical www.pacelabs.com May 03, 2001 Mr. Stan Bryson,` Tuckaseigee Water & Sewer Auth PO Box 1051 Sylva;=NC 28779 RE: Lab Project Number: 9319620 Client Project ID: ^ ��V-rVe--- Dear Mr. Bryson: Pace Analytical Services, Inc. 54 Ravenscroft Drive Asheville, NC 28801 Phone: 828.254.7176 Fax: 828.254.4618 Enclosed are the analytical results for sample(s)received by the laboratory on April 11, 2001. If you have any questions concerning this report, please feel free to contact me. Sincerely, Katherine Jimison Project Manager Enclosures Laboratory Certification IDs REPORT OF LABORATORY ANALYSIS Laboratory Certification IDs NC Wastewater 40 TN Drinking Water 02980 NC Drinking Water 37712 This report shall not be reproduced, except in full, SC Environmental 99030 without the written consent of Pace Analytical Services, Inc. aceAnalyticalTm www.pacelabs.com :aseigee Water & Sewer Auth Pb Box 1051 Sylva, NC 28779 Attn: Mr. Stan Bryson Phone: (828)586-9318 Solid results are reported on a dry weight basis Lab Sample No:-, _'93839439 Project Sample Number: 931S Client Sampl ::ID: TWSA LIME RESIDUAL Matrix: Soil Parameters Results Units PRL Metals Metals, ICP, trace -level Method: EPA 6010 Aluminum 10000 mg/kg 44. Arsenic 1.8 mg/kg 1.7 Cadmium 0.99 mg/kg 0.17 Calcium 280000 mg/kg 17. rhromium 7.9 mg/kg 0.87 Viper 91. mg/kg 0.87 Lead 7.8 mg/kg 1.7 Magnesium 3000 mg/kg 17. Molybdenum 2.3 mg/kg 0.87 Nickel 4.0 mg/kg 0.87 Potassium 1500 mg/kg 87. Sodium 400 mg/kg 44. Zinc 150 mg/kg 3.5 Date Digested Pace Analytical Services, Inc. 54 Ravenscro(t Drive Asheville, NC 28801 Phone: 828.254.7176 Fax: 828.254.4618 Lab Project Number: 9319620 Client Project ID: COMPOST -001 Date Collected: 04/11/01 09:00 Date Received: 04/11/01 14:00 Analyzed Analyst CAS# Ftnote Limit Prep Method: EPA 3050 04/23/01 TRW 7429-90-5 04/23/01 TRW 7440-38-2 04/23/01 TRW 7440-43-9 04/23/01 TRW 7440-70-2 04/23/01 TRW 7440-47-3 04/23/01 TRW 7440-50-8 04/23/01 TRW 7439-92-1 04/23/01 TRW 7439-95-4 04/23/01 TRW 7439-98-7 04/23/01 IRW 7440-02-0 04/23/01 TRW 7440-09-7 04/23/01 TRW 7440-23-5 04/23/01 TRW 7440-66-6 04/17/01 Mercury, CVAAS Method: EPA 7471 Prep Method: EPA 7471 Mercury 0.90 mg/kg 0.035 04/19/01 TRW 7439-97-6 Selenium, AAS Furnace Method: EPA 7740 Prep Method: EPA 3050 Selenium NO mg/kg 0.87 04/23/01 TRW 7782-49-2 1 Date Di9 ested 04/17/01 Wet Chemistry Percent Moisture Method: % Moisture Percent Moisture 42.8 % 04/13/01 AAB Date: 05/03/01 Laboratoryy Certification IDs REPORT OF LABORATORY ANALYSIS NC Wastewater 40 NC Drinking Water 37712 This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc. Page: 1 Laboratory Certification IDs TN Drinking Water 02980 SC Environmental 09030 • t aceAnalytical' www.pacelabs.com Lab Project Number: 9319620 Client Project ID: COMPOST Pace Analytical Services, Inc. 54 Ravenscrolt Drive Asheville, NC 28801 Phone: 828.254.7176 Fax:828,254.4618 Lab Sample No: 93839439 Project Sample Number: 9319620-001 Date Collected: 04/11/01 09:00 Client Sample ID: TWSA LIME RESIDUAL Matrix: Soil Date Received: 04/11/01 14:00 Parameters Results Units PRL Analyzed Analyst CAS# Ftnote Limit Method: Prep EPA 160.3 160.3 Method: EPA Total Percent Solids Percent Solids 57.0 1 04/13/01 AAB Ammonia, Soil Method: EPA 350.3 Prep Method: EPA 350.3 Nitrogen, Ammonia 760. mg/kg 8.74 04/25/01 JDA 7727-37-9 Total Kjeldahl Nitrogen, Soil Method: EPA 351.2 Prep Method: EPA 351.2 C¢ w -Nitrogen, Kjeldahl, Total 4370 mg/kg 8.74 04/19/01 JDA c a :. ,L Nitrogen, Nitrate plus Nitrite Method: EPA 353.2 Prep Method: EPA 353.2 `r) Nitrate -Nitrite (as N) 87. mg/kg 8.7 04/20/01 JDA 7727-37-9 �y Nitrogen, Nitrite, Soil Method: EPA 354.1 Prep Method: EPA 354.1�r Nitrite as N ND mg/kg 0.87 04/30/01 AAB W Phosphorus, Total, Soil Method: EPA 365.2 Prep Method: EPA 365.2 °hosphorus 76.3 mg/kg 2.19 04/13/01 MPS 7723-14-0 Fecal Coliform MPH Solid Method: SM 9221B/E Prep Method: SM 9221B/E Coliform, Fecal ND 2 04/12/01 KAS Nitrogen, Total Method: Standard Methods Nitrogen 4500 mg/kg 1.0 04/30/01 JDA 7727-37-9 Plant Available Nitrogen Method: Nitrogen 960 mg/kg 1.0 04/26/01 JDA 7727-37-9 Date: 05/03/01 Laboratory Certification IDs REPORT OF LABORATORY ANALYSIS NC Wastewater 40 NC Drinking Water 37712 This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc. Page: 2 Laboratoryy Certification IDs TN Drinking Water 02980 SC Environmental 99030 Pace Analytical Services, Inc. aceAnalytical m s Ralle, NoftDrive / Asheville, NC 28801 —/ Phone. 828.254.7176 www.pacelabs.com Far.` 828.254.4618 Lab Project Number: 9319620 Client Project ID: COMPOST PARAMETER FOOTNOTES ND Not Detected NC Not Calculable PRL Pace Reporting=Limit [1] Analyzed by,arace metals ICP, resulting in elevated PRL at 0.020 mg/l. 11 Date: 05/03/01 Page: 3 Laboratory Certification IDs REPORT OF LABORATORY ANALYSIS Laboratory Certification IDs NC Wastewater 40 TN Drinking Water 02980 NC Drinking Water 37712 This report shall not be reproduced, except in full, SC Environmental 99030 without the written consent of Pace Analytical Services, Inc. CHAIN-OF-CUSTUDY, / Analytical 'KequesT uolcumem The Chain -of -Custody is a LEGAL DOCUMENT. All relevant fields must be completed accurately. Paces Anaiviticcii AU The Right Chemistry, The Right SohitionO r., (1 -7 C 10 Page- Of Client Section C Required Client Information: Section A Required Client Information: Section B To Be Completed by Pace Analytical and Company 4R6pprt To: J Client Information. (Check quot /contract): Quote Reference: Actor Jrrll invoice To: I Requested Due Date: TAT: Project Manager: J V( - -- P.O. Turn around times less than 14 days subject to laboratory and contractual obligations and may result in Rush Turnaround Surcharge. a Project Project Name:. Profile #: -4 Turn Around Time (TAT) in calendar days. Pho I Fyax e Project Number: Requested Anal Section D Required Client Information: Valid Matrix Codes p p Preservatives MATRIX CODE w w LLJ w SAM PLE ID WATER SOIL WT SL C 0 C 0 w w 0 .2 w OIL OL 0 _J F- -J One character per box. WIPE AIR WIP AR X 0 0 0 0 «4W , 2 0. 0 0 0 0 (A—Z, 0-9 TISSUE TS G :D U) Z: z M 2: z zarks/ Lab ID Sample IDS MUST BE UNIQUE OTHER OT mm I dd yy hh: mm a/p i9 IT 1H" L a 7:t J, §Iniple Cooqitio . iry S.Imple Wte� 0 Adpepted Oyll C6mpan� DaW Tirne 71-T. 0 Mji Temp in 'C: '71— 1/r GI 7 Received on ICE: Y N Sealed Cooler: Y N L Samples Intact: Y N Additional Comments: OAMP�ER NA I�P D-13IGNATURE -ANE PRINT Namq_ot-6 - WPL SIGNATURE of DATE Signed: (MM DE? YY) A - SEE REVERSE SID, jR INSTRUCTIONS J Pace Analytical Services, Inc./ Fo DC01.XLS 12/99 13 �aceAnalytical.. www.pacelabs.com l_.,aseigee Water & Sewer Auth 10 Box 1051 ylva, NC 28779 ,ttn: Mr. Stan Bryson hone: (828)586-9318 olid results are reported on a dry weight basis Pace Analytical Services, Inc. 54 Ravenscrolt Drive Asheville, NC 28801 Phone: 828.254.7176 Fax., 828.252.4618 Lab Project Number: 9317865 Client Project ID: TWSA LIME RESIDUAL ab Sample No: 93774685 Project Sample Number: 9317865-001 Date Collected: 01/23/01 08:30 lient Sample.ID: TWSA LIME RESIDUAL Matrix: Soil Date Received: 01/23/01 13:25 arameters Results Units PRL Analyzed Analyst CAS# Ftnote Limit et Chemistry Percent Moisture Percent Moisture Fecal Coliform MPN Solid Coliform. Fecal v Date: 01/30/01 �r\ _aboratory Certification IDs UC Wastewater 40 VC Drinking Water 37712 Method: X Moisture 44.8 % Method:.SM 9221B/E ND 2 01/26/01 JMS Prep Method: SM 9221B/E 01/23/01 KAS REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc. Page: 1 Laboratory Certification IN TN Drinking Water 02980 SC Environmental 99030 IaneAnalyfical"' www.pacelabs.com ,�aseigee Water & Sewer Auth 0 Box 1051 ylva, NC 28779 ttn: Mr. Stan Bryson hone: (828)586-9318 olid results are reported on a dry weight basis ab Sample No: 93799815 lient Sample ID: TWSA LIME RESIDUAL arameters Results et Chemistry Percent Moisture Percent Moisture Fecal Coliform MPN Solid Col iform. Fecal 40 r Date: 03/05/01 Pace Analytical Services, Inc. 54 Ravenscroft Drive Asheville. NC 28801 Phone: 828.254.7176 Fax: 828.2524618 Lab Project Number: 9318507 Client Project ID: TWSA LIME RESIDUAL Project Sample Number: 9318507-001 Date Collected: 02/23/01 09:44 Matrix: Soil Date Received: 02/23/01 12:20 Units PRL Analyzed Analyst CAS# Ftnote Limit Method: X Moisture 46.5 Z Method: SM 9221B/E ND 2 02/28/01 AAB - Prep Method: SM 92216/E 02/23/01 KAS Page: 1 Laboratory Certification IDs REPORT OF LABORATORY ANALYSIS Laboratory Certification IDs NC Wastewater 40 TN Drinking Water 02980 NC Drinking Water 377�2 This report shall not be reproduced, except in full, SC Environmental 99030 without the written consent of Pace Analytical Services, Inc. .Analytical' (/ www.pacelabs.com iyckaseigee Water & Sewer Auth PO Box 1051 Sylva, NC 28779 Attn: Mr. Stan Bryson Phone: (828)586-9318 Solid results are reported on a dry weight basis Pace Analytical Services, Inc. 54 Ravenscroft Drive Asheville, NC 28801 Phone: 828.254.7176 Fax. 828.2524618 Lab Project Number: 9319068 Client Project ID: TWSA LIME RESIDUAL Lab Sample No: 93820009 Project Sample Number: 9319068-001 Date Collected: 03/21/01 10:00 Client Sample ID: TWSA LIME RESIDUAL Matrix: Soil Date Received: 03/21/01 16:37 Parameters Results Units PRL Analyzed Analyst CAS# Ftnote Limit Wet Chemistry Percent Moisture Percent Moisture Fecal Coliform MPN Solid Col iform, Fecal Date: 03/30/01 Method: % Moisture 47.7 % Method: SM 922113/E ND 2 03/27/01 TRW Prep Method: SM 9221B/E 03/22/01 KAS Page: 1 Laboratory Certification IDs REPORT OF LABORATORY ANALYSIS Laboratory Certification IDs NC Wastewater 40 TN Drinking Water 02980 NC Drinking Water 37712 This report shall not be reproduced, except in full, SC Environmental 99030 without the written consent of Pace Analytical Services, Inc. aceAnalytical www.pacelabs.com Lab Sample No: 93874469 Client Sample ID: TWSA LIME RESIDUAL:' Parameters Results Wet Chemistry Fecal Col i form, MPN' Sol i d Col i form, fecal Date: 05/30/01 Pace Analytical Services, Inc. 54 Ravenscroft Drive Asheville, NC 28801 Phone: 828.254.7176 Fax:828.254.4618 Lab Project Number: 9320539 Client Project ID: Effluent Analysis Project Sample Number: 9320539-002 Date Collected: 05/18/01 08:00 Matrix: Soil Date Received: 05/18/01 12:25 Units PRL Analyzed Analyst CAS# Ftnote Limit Method: SM 9221B/E Prep Method: SM 922113/E ND 2 05/18/01 KAS Page: 2 Laboratory Certification IDs REPORT OF LABORATORY ANALYSIS Laboratory Certification IDs NC Wastewater 40 TN Drinking Water 02980 NC Drinking Water 37712 This report shall not be reproduced, except in full, SC Environmental 99030 without the written consent of Pace Analytical Services, Inc. Pace Analytical Services, Inc. 54 Ravenscroft Drive Asheville, NC 28801 Phone. 828.254.7176 Fax.- 828.254.4618 Lab Project Number: 9321567 Client Project ID: LIME RESIDUAL FECAL 4ttn: Mr. Stan Bryson 'hone: (828)586-9318 Solid results are repo. _ab Sample No;„-.I-:,�'93913853 Project Sample Number: 9321567-001 Date Collected: 06/28/01 12:00 :lient SamD: TWSA LIME RESIDUAL Matrix: Soil Date Received: 06/28/01 15:44 'arameters Results Units PRL Analyzed Analyst CAS# Ftnote Limit C r LIJ tl det Chemistry Percent Moisture Percent Moisture Fecal Coliform MPN Solid Coliform, Fecal Date: 07111JOI aboratory Certification IDs OG Wastewater 40 NC Drinking Water 37712 on a dry weight basis Method: % Moisture 45.6 % Method: SM 9221B/E ND 2 _ 1 LU C.) LLf 07/09/01 AAB Prep Method: SM 9221B/E 06/29/01' KAS REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc_ N •ccaA Page: 1 Laboratory Certification IDs TN Drinking Water 02980 SC Environmental 99030 4ttn: Mr. Stan Bryson phone: (828)586-9318 iolid results are repoi on a dry weight basis Pace Analytical Services, Inc. 54 Ravenscrott Drive Asheville, NC 28601 Phone: 828,254.7176 Fax. 828.254.4618 Lab Project Number: 9321807 Client Project ID: TWSA LIME RESIDUAL .ab Sample No:,;.;%„-`93921765 Project Sample Number: 9321807-001 Date Collected: 07/12/01 08:00 aient Sample ID: TWSA LIME RESIDUAL Matrix: Soil Date Received: 07/12/01 09:08 'ara'6 ters -Chemistry Results Units Report Limit Analyzed CAS No. Ftnote Reg Limit 0 Percent Moisture Method: % Moisture Percent Moisture 47.7 1 07/16/01 AAB Fecal Coliform MPN Solid Prep/Method: SM 9221B/E / SM 9221B/E Coliform, Fecal ND 2 07/12/01 KAS Date: 07/20/01 Laboratory Certification IDs NC Wastewater 40 NC Drinking Water 37712 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc. y ACCOq Page: 1 Laboratory Certification IDs TN Drinking Water 02980 SC Environmental 99030 Pace Analytical Services, Inc. 54 Ravenscroft Drive Asheville, NC 28801 Phone. 828.254.7176 Fax.- 828.254.4618 Lab Project Number: 9322813 Client Project ID: TWSA LIME RESIDUAL Attn: Mr. Stan Bryson Phone: (828)586-9318 Solid results are repi Lab Sample No. ='93957645 Project Sample Number: 9322813-001 Client Sam„J:e=ID: TWSA LIME RESIDUAL Matrix: Soil - Pararoetgrs Results Units Report Limit Analyzed Wet` Chemistry Percent Moisture Method: Y Moisture Percent Moisture 41.0 Y 08/27/01 AAE Fecal Coliform MPN Solid Prep/Method: SM 9221B/E / SM 9221B/E Coliform, Fecal ND 2 08/21/01 KAS Date: 09/03/01 ` Laboratory Certification IDs NC Wastewater 40 NC Drinking Water 37712 on a dry weight basis Date Collected: 08/21/01 07:00 . Date Received: 08/21/01 12:04 CAS No. Ftnote Reg Limit REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc. lcco9 Page: 1 Laboratory Certification IN TN Drinking Water 02980 SC Environmental 99030 State of North Carolina Department of Environment and Natural Resources Division of Water Quality Michael F. Easley, Governor William G. Ross Jr., Secretary Kerr T. Stevens, Director Mr. Jerry R. King Tuckaseigee Water & Sewer Authority 123 E. Main St. Sylva, NC 28779 Dear Mr. King, NCDENR NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES July 18, 2001 VI 1:? JUL 2 320071 i Subject: Rescission of Notice of Violation/Notice of Intent to Enforce Tuckaseigee Water & Sewer Authority WQ0005763 Jackson County This letter is to inform you of the immediate rescission of the Notice of Violation/Notice of Intent to Enforce (NOV/NOI) issued to Tuckaseigee Water & Sewer Authority on May 4, 2001 for failure to submit an annual report in accordance with your permit. After a thorough file review by Division of Water Quality staff, it was determined that the NOV/NOI had been issued in error. Effective immediately, the Division of Water Quality hereby rescinds the NOV/NOI. I - We regret any inconvenience this NOV/NOI may have caused. If you have any questions concerning this matter, please do not hesitate to call Brian Wrenn of our Central Office staff at (919) 733-5083, ext. 529. Sincerely, v Dennis R. Ramsey, P.E. Assistant Chief for Non Discharge cc: Non Discharge Compliance /Enforcement Unit A`� sheville:!:R-egional_Ojfxce Central Files 1617 Mail Service Center, Raleigh, North Carolina 27699-1617 Telephone 919-733-5083 Fax 919-733-0059 An Equal Opportunity Affirmative Action Employer 50% recycled/10% post -consumer paper Michael F. Easley, Governor William G. Ross Jr., Secretary North Carolina - irtment of Environment and Natural Resources Gregory J. Thorpe, Ph.D. Acting Director Division of Water Quality October 12, 2001`4 mj-= `R JERRY R. KING TUCKASEIGEE W&S-A SLUDGE/COMP OCT r i z 123 E. MAIN ST.®�I SYLVA, NC 28779 0 ` RS�CV �Ul,LI LLLf `,fi I A&c', J� rfie�� Subject: PERMIT NO. WQ0005763. TUCKASEIGEE W&S-A SLUDGE/COMP JACKSON COUNTY Dear Permittee: Our files indicate that the subject permit issued on 10/18/96 expires on 9/30/01. We have not received a request for renewal from you as of this date. A renewal request shall consist of a letter asking for permit renewal and four (4) copies of a completed application. For permitted facilities with treatment works, a narrative description of the residuals management plan, which is in effect at the permitted facility, must also be submitted with the renewal application. Applications may be returned to the applicant if incomplete. The General Assembly passed legislation incorporating renewal fees into the annual fee. Please be advised that this permit must not be allowed to expire. You must submit the renewal request at least 180 days prior to the permit's expiration date, as required by the 15 NCAC 2H .0211. Failure to request a renewal at least 180 days prior to the permit expiration date and/or operation of a facility without a valid permit may result in the assessment of civil penalties. NCGS 143-215.6A allows for the assessment of Civil penalties up to $10,000 per violation per day. to: The letter requesting renewal, along with the completed Non -Discharge Permit Application must be sent Division of Water Quality Non -Discharge Permitting Unit 1617 Mail Service Center Raleigh, North Carolina 27699-1617 AVIA IICDERR' Customer Service 1 800 623-7748 ri r: N. C. Division of Water Quality 1617 Mail Service Center Raleigh, NC 27699-1617 (919) 733-7015 If you have any questions concerning this matter, please contact Thelma Williams at 919 733-5083 extension 556. Sincerely, Kim H. Colson, P.E., Supervisor Non -Discharge Permitting Unit cc: Asheville Regional Office Central Files State of North Carolina Department of Environment and Natural Resources Division of Water Quality Michael F. Easley, Governor William G. Ross Jr., Secretary Kerr T. Stevens, Director CERTIFIED MAIL RETURN RECEIPT REQUESTED Jerry R. King Tuckaseegee W&S 123 E. Main St. Sylva, NC 28779 Dear Jerry R. King: MAI NCDENR NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND_NATURAL REsSrJRCES May 4, 2001 y L 4 ��t l ► 0 2001 � Subject: Notice of Violation/Notice of Intent to Enforce Permit No. WQ0005763 Tuckaseegee W&S Land Application of Wastewater Residuals Jackson County This letter is to notify you that our records indicate a violation of your Permit No. WQ0005763. The Non -Discharge Compliance and Enforcement Unit of the Division of Water Quality has no record of receiving your 2000 Annual Report which was due on March 1, 2001. This is a violation of the Monitoring and Reporting Requirements detailed in Part III. of your Non -Discharge Permit. Please submit the 2000 Annual Report within 15 days of receipt of this letter. Please reference the state issued Permit Number when providing the requested information. All information should be signed and submitted in triplicate to the attention of Brian Wrenn at the letterhead address. Nothing in this letter should be taken as removing from you the responsibility or liability for failure to comply with all applicable state laws and regulations. The promptness of your response and any additional information that you wish to submit will be considered by the Director prior to deciding on the appropriate enforcement action to be taken. If you have any questions regarding this request, please do not hesitate to call Brian Wrenn of our Central Office staff at 919-733-5083 ext. 529. Sincerel Kerr T. Stevens., cc: Non -Discharge Compliance / Enforcement Unit Non -Discharge Permitting Unit .a.Ashevi�11�e�R� iona�l�Cl, �� _ Technical Assistance and Certification Unit Central Files 1617 Mail Service Center, Raleigh, North Carolina 27699-1617 Telephone 919-733-5083 Fax 919-733-0059 An Equal Opportunity Aff - native Action Employer 50% recycled/10% post -consumer paper North Carolina Department of Environment and Natural Resources Water Quality Michael F. Easley, Governor William G. Ross Jr., Secretary Kerr T. Stevens, Director January 24, 2001 JERRY R. KING TUCKASEIGEE W&S-A SLUDGE/COMP 123 E. MAIN ST. SYLVA, NC 28779 Subject: Dear JERRY R. KING: fflu'a"FA NCDENR Distribution and M Certification Form WQ0005763 JACKSON County Please find enclosed a copy of the Annual Distribution and Marketing/Surface Disposal Certification and Summary Form. This is the correct form that should be completed for your annual report due March 1, 2001 for all 2000 residuals activity. Please disregard the original certification form (Annual Land Application Certification Form) that was sent to you on January 12, 2001. If you have any questions, please contact me at (919) 733-5083, ext. 529. Sincerel , Brian L. Wrenn Environmental Specialist III Cc: ARV ` egiernal Non Discharge Compliance and Enforcement Central Files 1617 Mail Service Center, Raleigh, North Carolina 27699-1617 Phone: 919 — 733-5083 \ FAX: 919 — 733-0059 \ Internet: www.enr.state.nc.us/ENR/ AN EQUAL OPPORTUNITY \ AFFIRMATIVE ACTION EMPLOYER — 50% RECYCLED / 10% POST CONSUMER PAPER State of North Carolina Department of Environment and Natural Resources Division of Water Quality Michael F. Easley, Governor . Sherri Evans -Stanton, Acting Secretary Kerr T. Stevens, Director January 12, 2001 JERRY R. KING TUCKASEIGEE W&S-A SLUDGE/COMP 123 E. MAIN ST. SYLVA, NC 28779 0W4 • NCDENR NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES Subject: Annual Monitoring and Reporting Requirements Treatment and Land Application of Residuals Permit Number: WQ0005763 TUCKASEIGEE W&S-A SLUDGE/COMP JACKSON County Dear JERRY R. KING, The purpose of this letter is a reminder that the monitoring reports required by the subject permit must be submitted as an Annual Report for calendar year 2000 by no later than March 1, 2001. The report must be submitted (in triplicate) to the following address: DENR/DWQ/Water Quality Section Non -Discharge Compliance Unit 1617 Mail Service Center Raleigh, N.C. 27699-1617 Due to limitations in storage space, please submit the reports in bound form rather than in notebook form. Permittees are subject to civil penalty for failing to submit the Annual Report as required by their permit. Enclosed are the summary and certification sheets that must be used for your annual report. Please complete these sheets and if necessary make copies of the blank forms if extras are needed. The forms have not changed since last year, so you may use those you already have on hand. You will however note that the forms include additional information required by EPA as outlined in 40 CFR Part 503. Since the requirements of 40 CFR Part 503 are self implementing, they are legally binding and enforceable Federal requirements for all persons subject to the requirements of 40 CFR Part 503, even if these requirements are not currently contained in the State permit. The annual reports for the EPA must be received by EPA at the following address on or before Febuary 19, 2001. Hector Danois Clean Water Act Enforcement Section Water Programs Enforcement Branch Water Management Division U.S. EPA Region 4 61 Forsyth Street, S.W. Atlanta, Ga. 30303-3104 1617 Mail Service Center, Raleigh, North Carolina 27699-1617 Telephone 919-733-5083 Fax 919-733-0059 An Equal Opportunity Affirmative Action Employer 50% recycled/10% post -consumer paper Annual Monitoring and Reporting Requirements Page 2. If there is a need for any information or clarification on the State reporting requirements, please do not hesitate to contact me at (919) 733-5083 extension 529. For further information on the Federal requirements, you should call Madolyn Dominy of the Environmental Protection Agency at 404-562-9305. Brian L. Wrenn, Environmental Specialist III cc: Vince Miller, EPA Region IV ARO Regional Supervisor Non Discharge Compliance / Enforcement File Central Files State of North Carohiiia Department of Environment and Natural Resources Division of Water Quality James B. Hunt, Jr., Governor WaynBill Holman, Secretary Kerr T. Stevens, Director Certified Mail Return Receipt Requested July 10, 2000 MJerry R. King, Executive Director Tuckaseigee Water and Sewer Authority 123 East Main Street Sylva, North Carolina 28779-1051 NCDENR NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES Subject: Additional Information Request Permit No. WQ0005763 Tuckaseigee Water and Sewer Authority Distribution of Class A Wastewater Residuals Jackson County Dear Mr. King: The Non Discharge Compliance Unit is in receipt of your submitted, 1999 Annual Report of land application activities. The submitted report does not contain the requested residuals stabilization records for residuals produced during the 1999 calendar year. At a minimum, the submitted records should include a description of your stabilization process, process times and temperatures for each batch of Class A wastewater residual, and all fecal coliform bench sheets for each batch of Class A wastewater residual produced. You must submit all requested information within 1.0 days of receipt of this letter. Nothing in this letter should be taken as removing from you the responsibility or liability for failure to comply with all applicable state laws and regulations. If you have any questions regarding this request, please do not hesitate to call Kevin Barnett of the Non -Discharge Compliance / Enforcement Unit at 919-733-5083 ext. 529. Sinc.erely, Kevin H. Barnett Environmental Specialist III cc: Non -Discharge Compliance / Enforcement Unit Non -Discharge Permitting Unit Wanda Frazier, Asheville Regional Office Central Files Mailing Address: Telephone (919) 733-5083 1617 Mail Service Center Fax (919) 733-0059 Raleigh, North Carolina 27699-1617 State Courier #52-01-01 An Equal Opportunity /Affirmative Action Employer 50% recycled / 10% post -consumer paper http://`h20.enr.state.nc.us Location: 512 N. Salisbury St. Raleigh, NC 27699-1617 ppppr, BP Annual Report Review Class A Distribution Reporting Period: 4 A /1;T Permit Details: V)q,0005%3 Is 503? Y ClassaAior B? Maximum Dry Tons Per Year: (a�9 Number of acres permitted: N AN Number of fields in permit: /A Counties that land is permitted for: N IN Monitoring Frequency for TCLP: An ri u.A-1 Monitoring Frequency for Residuals Analysis:E,3. t t4 SYC Monitoring Frequency for Pathogen & Vector Attraction Reduction: HASM pj or . Class A Annual Distribution and Marketing/Surface Disposal Certification Form Was a certification form submitted? ►I b� No-� 'PtAk ForN� Was distribution conducted during the reported period? How many dry tons were produced and distributed? PAT X 6 9,5 Were the distributions with the permitted amount? Were recipients information listed? I Did it indicate compliance? 010 Was form complete? j/ Was it signed by the ppropriate people? ] 2. Monitoring Were the analyses conducted at the required frequency?, Was an analyses taken for each source that was distributed? Were the metals analyses reported on the Residual Sampling Summary Form? Were the results reported in mg/kg? Y, Were the pH's 6.0 or greater for each residual sample? Were the heavy metals within ceiling concentration permit limits? Were the lab analyses attached? Were all the required parameters tested? Was TCLP analysis conducted? y Were the TLCP contaminants within regulatory limits? Was a corrosivity, ignitability, and reactivity analysis conducted? 3. Pathogen and Vector Attraction Reduction Was a signed copy of the Pathos and Vector Attraction Reduction Form submitted? moor Did th�orm indicate the perio8 of covyage, the residual cla s and the pathogen reduction alternaTive and the vector attraction reduction option used? Was the appropriate documentation to show pathogen and vector attraction reduction included in the report? Was pathogen and vector attraction reduction dem{��o7nstrated according to 40 CFR Part 503?L Class A Pathogen Review w 16I ru.rl5 �? e-eslams �iduals shall meet either fecal Coliform density or salmonella density. Fecal Coliform density Was the sampling conducted at the required fre Zency? Were multiple samples taken? Was each sample less than 1000 MPN/gram of total solids? 1 Salmonella density Was the sampling conducted at the required frequency? Were multiple samples taken? Was each sample less than 3 MPN/4 grams of total solids? To be Class A, residuals shall meet one of the following alternatives: Alternative 1 — Time/Temperature Were the residuals maintained for correct time and temperature? Were logs submitted showing time and temperature? Were temperatures within range for complete time period? f- -qqN {o �C w A"'�a'w ar tk Alternative 2 — Alkaline Treatment Were logs submitted showing time and temperature? Was the pH raised to 12 or greater and maintained for 72 hours or longer? Was the temperature 52°C (126°F) for 12 hours or longer�*hile the pH was 12 or greater? Were logs submitted showing time and pH?, Was the temperature corrected to 25°C (77°F)? Alternative 5 — Process To Further Reduce Pathogens PFRP Composting Were the within -vessel method or static aerated pile methods used? Was the residuals temperature maintained at 55°C (131°F) or higher for three consecutive days or longer in the within -vessel method or static aerated pile method? OR Was the windrow composting method used? Was the residuals temperature maintained at 55°C or higher for 15 consecutive days or longer in the windrow method, and the windrow turned a minimum of five times during this time? PFRP Heat Drying • Was the residuals dried by direct or indirect contact with hot gases and the osture content of residuals reduced to 10% or lower? t q � & � 1.1110i. • Did the temperature of the residuals or the of the wet bulb temperature of the gas in contact with the residuals as the residuals leave the dryer exceed 80°C (176°F)? c�ry¢� rc��s 2So Vector Attraction Reduction Review ,,` It- Was the sampling conducted at the required frequency? Option 1 — 38% Volatile Solids Reduction Was there 38% reduction? Were lab sheets/calculations in report? Was the reduction on volatile solids (not total solids)? • Were the samples taken at beginning of digestion process and before application (Inspection)? • Were calculations correct? Option 2 — 40-Day Bench Scale Test Were residuals from anaerobically digested treatment (Inspection)? Were residuals anaerobically digested in lab? Was the test run for 40 days? Was the test done between 30°C (86°F) and 37°C (99°F)? Was the reduction of on volatile solids (not total solids)? Was the reduction less than 17%? Were lab sheets/calculations in report? Were calculations correct? Option 3 — 30-Day Bench Scale Test Were residuals from aerobically digested treatment (Inspection)? Were residuals aerobically digested in lab? Were residuals 2% or less total solids? If not 2% total solids, was the test ran on a sample diluted to 2% with unchlorinated effluent? Was the test run for 30 days? Was the test done at 20°C (68°F)? Was the reduction of on volatile solids (not total solids)? Was the reduction less than 15%? Were lab sheets/calculations in report? Were calculations correct? Option 4 — Specific Oxygen Uptake Rate(SOUR) Were residuals form aerobically digested treatment (Inspection)? Were residuals 2% or less total solids (dry weight basis) (not diluted)? Was the test done between 10°C (50°F) and 30°C (86°F)? Was the temperature corrected to 20°C (68°F)? Was the SOUR equal to or less than 1.5 mg of oxygen per hour per gram of total residual solids (dry weight basis)? Was the sampling holding time two hours? Was the test started within 15 minutes of sampling or aeration maintained? Option 5 —14-Day Aerobic Process Were the residuals from aerobically digested treatment (Inspection)? Were the residuals treated for 14 days? Was the residuals temperature higher than 40°C (104°F) for a 14-day period? Was the average residuals temperature higher than 45°C (113°F)? Option 6 — Alkaline Stabilization Was the pH of the residuals raised to 12 or higher by the addition of alkali? Did the pH of residuals remain at 12 or higher for two hours without the addition of more alkali? • Did the pH of residuals remain at 11.5 or higher for an additional twenty-two hours without the addition of more alkali? Was the pH corrected to 25°C (77°F)? Option 7 — Drying of Stabilized Residuals d �es,� Does the residuals contain any unstabilized residuals�?Vby Were the residuals mixed with any other materials? I R �/ Were the residuals dried up to 75% total solids?y ` 6 L _A � _Za_J Option 8 —Drying of Unstabilized Residuals Were the residuals mixed with any other materials? Were the residuals dried to 90% total solids?gyp Option 9 —Injection • Was there any significant amount of residuals on land surface one hour after injection (Inspection)? Was injection done on pasture or hay field? Was injection done at time that crop was growing? If Class A with respect to pathogen, were residuals injected with eight hours after discharge from pathogen treatment? 4.General Was the report in the proper format? Was the annual report complete?l l Was the report submitted on time? 1A.0 �r 5 0 Lem Wa,l VwA- 5JIA i�rrowe ��G con r,,A -- C-i ASS -\- CDj„_1po_54- ��-CS 214 h o IA Tin. e,s VA to I f�g� �+^ e eiU Fe-c-4 Y �_M Cl- 0 C,I :ASS B � �3� :d- - d L 1 k �� s '90l n� u r1 - nn� �s �p���� �2u (e, P� c�6 a �i ed pc I I k S Environmental Testing Solutions, Inc. Certificate of Analysis Project name: Tuckaseigee Water && Sewer Collection date: 18-Oct-17 Date received: 19-Oct-17 Sample identification: TWSA Dried Residue Load #2 - Grab Parameter Sludge Fecal %Total Solids SM 9911 SM 264p G 1960 • 1 98 •,d PO Box 7565 Asheville, NC 28802 Phone: (828) 350-9364 Fax: (828) 350-9368 Project number: 171019.516 UJ Sample number: 152189 Ze ✓ Gam' Date ;Units Analyzed Analyst Footnotes >� % 19-00-17 KEK 4 19-opt-17 KEK Sample identification: TWSA Dried Residue Load #1?--Grab,— `" Sample number: 152190 Parameter Method Result RL Units Date Analyst Footnotes Analyzed Sludge Fecal SM 9921 E 169 1.69 % 19-Oct-17 KEK % Total Solids SM 2540 G 94 0.10 % 19•oct-17 KEK Collection date: 19-Oct-1'7 Date received: 19-Oct-17 Sample identification:; TWSA Dried Residue Load #1- Grab Sample number: 152191 Parameter Method Result RL Units Date Analyst Footnotes Analyzed . Sludge Fecal SM 9921 E <175 , 175 % 19-opt-17 ICEK % Total Solids SM 2540 G 97 0.10 % 19-00-17 KEK I\ R Permit: WQ0005763 SOC: County: Jackson Region: Asheville Compliance Inspection Report Effective: 09/11/14 Expiration: 07/31/19 owner: Tuckaseigee Water & Sewer Authority Effective: Expiration: Facility: Jackson County WWTP 1871 N River Rd Sylva NC 28779 Contact Person: Dan Harbaugh Title: Executive Director Directions to Facility: Hwy 40 W to Hwy. 74 W to Dillsboro. Hwy. 23 South to River Road. Facility is located at 1871 N River Rc System Classifications: Primary ORC: Certification: Secondary ORC(s): On -Site Representative(s): 24 hour contact name Stan D Bryson On -site representative Stan D Bryson Related Permits: NCO063321 Tuckaseigee Water & Sewer Authority - TWSA Plant #3 NCO087602 Tuckaseigee Water & Sewer Authority - Whittier WWTP NCO020214 Tuckaseigee Water & Sewer Authority - TWSA WWTP#2 NCO039578 Tuckaseigee Water & Sewer Authority - Jackson County WWTP Inspection Date: 04/23/2018 Entry Time: 09:30AM Exit Time: 10:15AM Primary Inspector: Beverly Price Secondary Inspector(s): Mika] Willmer Phone: 828-586-5189 Ext.203 Phone: 828-586-9318 828-586-9318 Phone: 828-296-4500 Reason for Inspection: Other Inspection Type: Technical Assistance Permit Inspection Type: Distribution of Residual Solids (503) Facility Status: ❑ Compliant ❑ Not Compliant Question Areas: Miscellaneous Questions Pathogen and vector Attraction (See attachment summary) Page: 1 Permit: W00005763 Owner - Facility: Tuckaseigee Water & Sewer Authority Inspection Date: 04/23/2018 Inspection Type : Technical Assistance Reason for Visit: Other Inspection Summary: The purpose of the technical assistance site visit was to split a biosolids (Class A) sample with the facility. The inspection was conducted by Beverly Price & Mikal Willmer of the ARO. Mr. Stan Bryson assisted with the inspection. Fecal coliform samples were collected from the residuals silo. One sample was sent to PACE Analytical and the other sample was analyzed at the Asheville Regional Office lab. The ARO laboratory result was 1.8 MPN Index/100 Method Reference SM 20th ed 9221C. This sample was for technical assistance to determine analytical consistency. It is recommended that additional split sampling, a 3-way split if possible, be conducted. It is recommended that the fecal coliform sample be collected as it exits the storage silo. This recommendation is based on the information provided in the Environmental Regulations and Technology Control of Pathogens and Vector Attraction in Sewage Sludge (aka the "White House Manual") guidance document provided by the EPA. The references in the "White House Manual" can be found in the following sections: Chapter 4: Class A Pathogen Requirements, Section 4.3: Monitoring of Fecal Coliform. Chapter 7: Processes to Further Reduce Pathogens (PFRPs), Section 7.3: Heat Drying, Microbiological Requirements. Page: 2 Permit: WQ0005763 Owner - Facility: Tuckaseigee Water & Sewer Authority Inspection Date: 04/23/2018 Inspection Type : Technical Assistance Reason for Visit: Other Type Land Application Distribution and Marketing Pathogen and Vector Attraction a._ Fecal coliform SM 9221 E (Class A or B) Class A, all test must be <1000 MPN/dry gram Geometric mean of 7 samples per monitoring period for class B<2.0*10E6 CFU/dry gram Fecal coliform SM 9222 D (Class B only) Geometric mean of 7 samples per monitoring period for class B<2.0*10E6 CFU/dry gram b. pH records for alkaline stabilization (Class A) c. pH records for alkaline stabilization (Class B) Temperature corrected d. Salmonella (Class A, all test must be < 3MPN/4 gram day) e. Time/Temp on: Digester (MCRT) Compost Class A lime stabilization f. Volatile Solids Calculations g. Bench -top Aerobic/Anaerobic digestion results Comment: Yes No NA NE El Yes No NA NE ❑ ❑ ❑ ❑ ❑E ❑ ❑ ❑ ❑ ❑❑■❑ ❑❑■❑ ❑ ❑ ❑ ❑ ❑ E ❑ Page: 3 /Permit: WQ0005763 SOC: County: Jackson Region: Asheville Compliance Inspection Report Effective: 09/11/14 Expiration: 07/31/19 Owner: Tuckaseigee. Water & Sewer Authority Effective: Expiration: Facility: Jackson County WWTP 1871 N River Rd Contact Person: Dan Harbaugh Title: Executive Director Sylva NC 28779 Phone: 828-586-5189 Ext.203 Directions to Facility: Hwy 40 W to Hwy. 74 W to Dillsboro. Hwy. 23 South to River Road. Facility is located at 1871 N River Rd System Classifications: Primary ORC: Certification: Phone: Secondary ORC(s): On -Site Representative(s): 24 hour contact name Stan D Bryson 919-346-8443 Related Permits: NC0063321 Tuckaseigee Water & Sewer Authority - TWSA Plant #3 NC0087602 Tuckaseigee Water & Sewer Authority - Whittier WWTP NC0020214 Tuckaseigee Water & Sewer Authority - TWSA WWTP#2 NC0039578 Tuckaseigee Water & Sewer Authority - Jackson County WWTP Inspection Date: 10/31/2018 Entry Time: 09:OOAM Exit Time: 11:30AM Primary Inspector: Beverly Price Phone: 828-296-4500 Secondary Inspector(s): Reason for Inspection: Routine Permit Inspection Type: Distribution of Residual Solids (503) Facility Status: ❑ Compliant Not Compliant Question Areas: Miscellaneous Questions Record Keeping Pathogen and Vector Attraction (See attachment summary) Inspection Type: Annual Report Review Treatment Page: 1 Permit: W00005763 Owner - Facility: Tuckaseigee Water & Sewer Authority Inspection Date: 10/31/2018 Inspection Type: Annual Report Review Reason for Visit: Routine Inspection Summary: The inspection consisted of a review of the 2017 Annual Report. The review was conducted by Beverly Price of the Asheville Regional Office. 294 dry tons of residuals were distributed in 2017. Based on the volume distributed in 2017, 1/year monitoring was required for metals, nutrients and 'pathogen & vector attraction reduction (VAR). Residuals were monitored for metals/nutrients/TCLP/Ignitability/Corrosivity/Reactivity - Analytical results appeared to be compliant with permit conditions. TCLP monitoring is required annually. Pathogen Reduction is verified using Fecal Coliform Density: requirements were met. Five compliance (collected from the silo) samples were collected; one sample was run out of hold time. Pathogen Reduction is verified using Alternative #5 Process to Futher Reduce Pathogens - PFRP Heat Drying — Requirements: Moisture Content: 10% or lower when residuals are dried by indirect or direct contact with hot gases. Temperature Requirement: 80 degrees C (176 degrees F) for residuals or the wet bulb temperature of the gas in contact with the residuals as the residuals leave the dryer: Residuals met the requirement for percent (10%) moisture reduction. The documented dryer temperatures for residuals leaving the dryer were met less than 1/2 of the dryer runs. Vector traction_Reduction is verifieausi'n'g-Option-8--0rying-of-ldrtstabillzed Residuals - Requirements: Solids content is 90% or greater. Division approved Forms should be used for reporting. Annual Pathogen and Vector Attraction Reduction Form: Do not calculate or report the Geometric Mean for fecal coliform analyses. The Geometric Mean is used to determine compliance for fecal coliform bacteria analyses for Class B residuals. Class A residuals require all samples to be <1000 MPN/gram of total solids. Do not report process control results on this Form. Please include the Analytical Method on this Form. Sampling Guidance for Pathogen/Vector Attraction Reduction: The EPA Environmental Regulations and Technology, Control of Pathogens and Vector Attraction in Sewage Sludge guidance document (also known as the White House Manual (WHM))does not specify the number of samples that must be analyzed for compliance with Class A microbiological parameters, however, it strongly recommends multiple samples per sampling event. The number of samples taken must be sufficient to adequately represent biosolids quality. Please review the WHM Chapter 4 - Class A Pathogen Requirements, Section 4.3. Monitoing of Fecal Coliform to Detect Growth of Bacterial Pathogens; Chapter 7 - Processes to Futher Reduce Pathogens, Sections 7.1 Introduction, 7.3 Heat Drying; Chapter 9 - Sampling Procedures and Analytical Methods, Section 9.5 Sampling Frequency and Number of Samples Collected, Section 9.8 Sampling Dry Sewage Sludges; Chapter 10 - Meeting the Quantitative Requirements of the Regulation, Section 10.1 Introduction, Section 10.3 Schedule and Duration of Monitoring Event, Section 10.7 Regulatory Objectives and Number of Samples that Should be Tested. For process control samples used for Percent Solids: If samples are re -set, the results of the two samples should be averaged. For Sodium Adsorption Ratio (SAR) calculations: sodium, calcium and magnesium should be converted from mg/kg to mg/I in order to determine milli equivalents. Page: 2 Permit: WQ0005763 Owner - Facility: Tuckaseigee Water & Sewer Authority Inspection Date: 10/31/2018 Inspection Type: Annual Report Review Reason for Visit: Routine Type Land Application Distribution and Marketing Record Keeping Is GW monitoring being conducted, if required? Are GW samples from all MWs sampled for all required parameters? Are there any GW quality violations? Is GW-59A certification form completed for facility? Is a copy of current permit on -site? Are current metals and nutrient analysis available?. Are nutrient and metal loading calculating most limiting parameters? a. TCLP analysis? b. SSFA (Standard Soil Fertility Analysis)? Are PAN balances being maintained? Are PAN balances within permit limits? Has land application equipment been calibrated? Are there pH records for alkaline stabilization? Are there pH records for the land application site? Are nutrient/crop removal practices in place? Do lab sheets support data reported on Residual Analysis Summary? Are hauling records available? Are hauling records maintained and up-to-date? # Has permittee been free of public complaints in last 12 months? Has application occurred during Seasonal Restriction window? Comment: Arsenic sample reported 8/1/18 was 1.0 mg/I. The laboratory report showed 1.4 mg/I. Pathogen and Vector Attraction a. Fecal coliform SM 9221 E (Class A or B) Class A, all test must be <1000 MPN/dry gram Geometric mean of 7 samples per monitoring period for class B<2.0*10E6 CFU/dry gram Fecal coliform SM 9222 D (Class B only) Geometric mean of 7 samples per monitoring period for Gass B<2.0*10E6 CFU/dry gram b. pH records for alkaline stabilization (Class A) c. pH records for alkaline stabilization (Class B) Temperature corrected d. Salmonella (Class A, all test must be < 3MPN/4 gram day) Yes No NA NE Yes No NA NE ❑ ❑ M ❑ ❑❑■❑ ❑❑■❑ ❑❑■❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ■❑❑❑ ❑❑■❑ ❑ ❑ M ❑ ❑ ❑ ❑ ❑ M ❑ ❑ ❑ ❑ ❑ ❑ ❑ . ❑ ❑ ❑ ❑ ❑ M ❑ ❑ Yes No NA NE ■❑❑❑ ❑❑■❑ ❑❑■❑ ❑ ❑ M ❑ R. ❑❑■❑ Page: 3 Permit: WQ0005763 Owner - Facility: Tuckaseigee Water & Sewer Authority Inspection Date: 10/31/2018 Inspection Type: Annual Report Review Reason for visit: Routine e. Time/Temp on: ❑ 0 ❑ ❑ Digester (MCRT) ❑ Compost ❑ Class A lime stabilization ❑ I Volatile Solids Calculations ❑ ❑ 0 ❑ g. Bench -top Aerobic/Anaerobic digestion results ❑ ❑ N ❑ Comment: Residuals Temperature: Sewage sludge is dried by direct or indirect contact with hot qases to reduce the moisture content of the sewage sludge to 10 percent or lower. Either the temperature of the sewage sludge particles exceeds 80 degrees Celsius or the wet bulb temperature of the gas in contact with the sewage sludge as the sewage sludge leaves the dryer exceeds 80 degrees Celsius. The Discharge Product temperature recorded on the Dyer Operations Daily Record log showed that the required temperature was met less than 1/2 of the time. Treatment Yes No NA NE Check all that apply Aerobic Digestion Anaerobic Digestion ❑ Alkaline Pasteurization (Class A) ❑ Alkaline Stabilization (Class B) ❑ Compost ❑ Drying Beds ❑ Other Comment: Drver Page: 4 Permit: WQ0005763 SOC: ' County: Jackson Region: Asheville Compliance Inspection Report Effective: 09/11/14 Expiration: 07/31/19 Owner: Tuckaseigee Water & Sewer Authority Effective: Expiration: Facility: Jackson County WWTP 1871 N River Rd Sylva NC 28779 Contact Person: Dan Harbaugh Title: Executive Director Directions to Facility: Hwy 40 W to Hwy. 74 W to Dillsboro. Hwy. 23 South to River Road. Facility is located at 1871 N River Rc System Classifications: Primary ORC: Certification: Secondary ORC(s): On -Site Representative(s): 24 hour contact name Stan D Bryson Related Permits: NC0063321 Tuckaseigee Water & Sewer Authority - TWSA Plant #3 NC0087602 Tuckaseigee Water & Sewer Authority - Whittier WWTP NC0020214 Tuckaseigee Water & Sewer Authority - TWSA WWTP#2 NC0039578 Tuckaseigee Water & Sewer Authority - Jackson County WWTP Inspection Date: 12/18/2017 Entry Time: 03:OOPM Exit Time: 04:OOPM Primary Inspector: Beverly Price ` Secondary Inspector(s): Reason for Inspection: Routine Permit Inspection Type: Distribution of Residual Solids (503) Facility Status: ❑ Compliant Not Compliant Question Areas: Miscellaneous Questions Record Keeping (See attachment summary) Phone: 828-586-5189 Ext.203 Phone: 828-586-9318 Phone: 828-296-4500 Inspection Type: Annual Report Review Pathogen and Vector Attraction Page: 1 Permit: WQ0005763 Owner - Facility: Tuckaseigee Water & Sewer Authority Inspection Date: 12/18/2017 Inspection Type: Annual Report Review Reason for Visit: Routine Inspection Summary. The inspection consisted of a review of the 2016 Annual Report. The review was conducted by Beverly Price of the Asheville Regional Office. 54 dry tons of residuals were distributed in 2016. 90.09 tons of residuals were hauled in 2016 by private contractor to: R&B Landfill - operated by Waste Management Inc. 610 Frank Bennett Road Homer Ga. 30080 Residuals were monitored for metals/nutrients/TCLP/Ignitability/Corrosivity/Reactivity -Analytical results appeared to be compliant with permit conditions. Pathogen Reduction verification via Fecal Coliform Density: requirements were met. T_ o fecal coliform samples collected from the silo in November exceeded the limit for Class A residuals. Three additional samples were collet a an resu '—' were compliant. PathogenNector Attraction Reduction verification via Alternative #5 - Heat Drying - Eight dryer runs appeared to not meet the moisture reduction requirement of 90%. Page: 2 Permit: WQ0005763 Owner - Facility: Tuckaseigee Water & Sewer Authority Inspection Date: 12/18/2017 Inspection Type: Annual Report Review Reason for Visit: Routine Type Land Application Distribution and Marketing Yes No NA NE Record Keeping Yes No NA NE Is GW monitoring being conducted, if required? ❑ ❑ ❑ Are GW samples from all MWs sampled for all required parameters? ❑ ❑ N ❑ Are there any GW quality violations? ❑ ❑ 0 ❑ Is GW-59A certification form completed for facility? ❑ ❑ 0 ❑ Is a copy of current permit on -site? ❑ ❑ ❑ Are current metals and nutrient analysis available? ❑ ❑ ❑ Are nutrient and metal loading calculating most limiting parameters? 0 ❑ ❑ ❑ a. TCLP analysis? E ❑ ❑ ❑ b. SSFA (Standard Soil Fertility Analysis)? ❑ ❑ 0 ❑ Are PAN balances being maintained? ❑ ❑ ❑ Are PAN balances within permit limits? ❑ ❑ ❑ Has land application equipment been calibrated? ❑ ❑ 0 ❑ Are there pH records for alkaline stabilization? ❑ ❑ ❑ Are there pH records for the land application site? ❑ ❑ ❑ Are nutrient/crop removal practices in place? ❑ ❑ ❑ Do lab sheets support data reported on Residual Analysis Summary? 0 ❑ ❑ ❑ Are hauling records available? 0 ❑ ❑ ❑ Are hauling records maintained and up-to-date? ❑ ❑ ❑ #'Has permittee,been free of public complaints in last 12 months? ❑ ❑ ❑ Has application occurred during Seasonal Restriction window? ❑ ❑ E ❑ Comment: 54 dry tons of residuals were distributed to the public in 2016 - hauling records were provided. 90.09 tons of residuals were landfilled in 2016. Hauling tickets were not provided in the Annual Report but are available upon request per Stan Bryson. Pathogen and Vector Attraction a. Fecal coliform SM 9221 E (Class A or B) Class A, all test must be <1000 MPN/dry gram Geometric mean of 7 samples per monitoring period for class B<2.0*10E6 CFU/dry gram Fecal coliform SM 9222 D (Class B only) Geometric mean of 7 samples per monitoring period for class B<2.0*10E6 CFU/dry gram b. pH records for alkaline stabilization (Class A) c. pH records for alkaline stabilization (Class B) Yes No NA NE ■❑❑❑ ❑ ❑ ❑ ❑ ❑ E ❑ ❑ ❑ E ❑ Page: 3 Permit: WQ0005763 Owner - Facility: Tuckaseigee Water & Sewer Authority Inspection Date: 12/18/2017 Inspection Type: Annual Report Review Temperature corrected d. Salmonella (Class A, all test must be < 3MPN/4 gram day) e. Time/Temp on: Digester (MCRT) Compost Class A lime stabilization f. Volatile Solids Calculations g. Bench -top Aerobic/Anaerobic digestion results Comment: Reason for Visit: Routine Page: 4 Permit: WQ0005763 SOC: County: Jackson Region: Asheville Compliance Inspection Report Effective: 10/08/10 Expiration: 07/31/14 Owner: Tuckaseigee Water & Sewer Authority Effective: Expiration: Facility: Jackson County WWTP 1871 N River Rd Sylva NC 28779 Contact Person: Dan Harbaugh Title: Executive Director Directions to. Facility: Hwy 40 W to Hwy. 74 W to Dillsboro. Hwy. 23 South to River Road. Facility is located at 1871 N River Rc System Classifications: Primary ORC: Certification: Secondary ORC(s): On -Site Representative(s): 24 hour contact name On -site representative Related Permits: Inspection Date: 06/19/2014 Primary Inspector: Beverly Price Secondary Inspector(s): Stan D Bryson Stan D Bryson Entry Time: 01:OOPM Exit Time: 01:45PM Reason for Inspection: Routine Permit Inspection Type: Distribution of Residual Solids (503) Facility Status: Compliant ❑ Not Compliant Question Areas: Miscellaneous Questions Record Keeping Sampling (See attachment summary) Phone: 828-586-5189 Phone: 828-586-9318 828-586-9318 Phone: 828-296-4500 Inspection Type: Compliance Evaluation E Treatment Page: 1 Permit: WQ0005763 Owner - Facility: Tuckaseigee Water & Sewer Authority Inspection Date: 06119/2014 Inspection Type: Compliance Evaluation Reason for Visit: Routine Inspection Summary: This site visit included a tour of the facility. Sludge from the other 3 facilites and WWTP#1 is mixed in the upper aerobic digester. The thickened sludge from the upper digester is sent to the lower digester and mixed/aerated further. From here the sludge goes to the belt -press and then to the dryer. The maintenance/operation logs were good. Dried sludge is stored in the silo. A Non -Hazardous Manifest is filled out each time the hauler comes to pick up residuals. A Spill Control Plan is located on the back of the manifest. Soil Plus, Inc. is currently taking the sludge. Kinsland Trucking out of Whittier, NC is hauling the product for Soil Plus (Scott Carpenter). In addition to the nutrient analysis performed by Tuckaseigee, Mr. Carpenter has the product analyzed for nutrient content by A&L Eastern Labs. Mr. Bryson indicated that he might need to send some product to the landfill to make room in the silo. Page: 2 permit: W90005763 Owner - Facility: Tuckaseigee Water & Sewer Authority Inspection Date: 06/19/2014 Inspection Type: Compliance Evaluation Reason for Visit: Routine Tvpe Yes No NA NE Land Application ❑ Distribution and Marketing Record Keeping Yes No NA NE Is GW monitoring being conducted, if required? ❑ ❑ E ❑ Are GW samples from all MWs sampled for all required parameters? ❑ ❑ ❑ Are there any GW quality violations? ❑ ❑ E ❑ Is GW-59A certification form completed for facility? ❑ ❑ 0 ❑ Is a copy of current permit on -site? N ❑ ❑ ❑ Are current metals and nutrient analysis available? ❑ ❑ N ❑ Are nutrient and metal loading calculating most limiting parameters? ❑ ❑ 0 ❑ a. TCLP analysis? ❑ ❑ 0 ❑ b. SSFA (Standard Soil Fertility Analysis)? ❑. ❑ 0 ❑ Are PAN balances being maintained? ❑ ❑ E ❑ Are PAN balances within permit limits? ❑ ❑ N ❑ Has land application equipment been calibrated? ❑ ❑ ❑ Are there pH records for alkaline stabilization? ❑ ❑ 0 ❑ Are there pH records for the land application site? ❑ ❑ 0 ❑ Are nutrient/crop removal practices in place? ❑ ❑ E ❑ Do lab sheets support data reported on Residual Analysis Summary? ❑ ❑ 0 ❑ Are hauling records available? ❑ ❑ Are hauling records maintained and up-to-date? ❑ ❑ N ❑ # Has permittee been free of public complaints in last 12 months? ❑ ❑ E ❑ Has application occurred during Seasonal Restriction window? ❑ ❑ N ❑ Comment: Treatment Yes No NA NE Check all that apply Aerobic Digestion Anaerobic Digestion ❑ Alkaline Pasteurization (Class A) ❑ Alkaline Stabilization (Class B) ❑ Compost ❑ Drying Beds ❑ Other Comment: Hot oil dryer Page: 3 Permit: WO0005763 Owner - Facility: Tuckaseigee Water & Sewer Authority Inspection Date: 06/19/2014 Inspection Type : Compliance Evaluation Reason for Visit: Routine Sampling Yes No NA NE Describe sampling: Total percent solids samples are colleced at the hopper from each batch run from the dyer. Fecal coliform, metals, nutrients and TCLP samples are collected either from the hopper or from the storage silo. Is sampling adequate? Is sampling representative? M El El El Comment: Page: 4 TWSA , Operation and Maintenance Plan For Residual Operations The residual operations at TWSA consist of the following main processes. .(a) Aerobic Digestion When sludge. is wasted from the sbrs it is routed to one of the two aerobe (digestor #1) has a capacity of 285,000 gals. The lower digestor (digestor #2 ihestors. The upper digestor gals. The operator can route sludge flow to the digestors from,the waste sludge pumps in the sbrs by using the valves on the waste sludge line. The valves an) as a capacity of 345,000 C5 of the record drawings by McGill Assoc. dated 10/12/2012 dated sludge i in are shown on Sheet Piping (b) Sludge Pump The sludge pump for the belt press is a progressive cavity pumP(yp t e BN 52-6Ls/A1-C1- - manufactured by Seepex Inc and rated for a pump rate cavity 7.00 C6 FO SA-X) basement of the sludge pump/reusewater pump building. The location of thisPUMpbuildin o is located in the shown on Sheet C3 of the record drawings by McGill Assoc. dated 10/12/2012. The details are shown on Sheet IVI21 of the. record drawings Gi McGill Assoc. date g °n the site is ails of the piping operation and maintenance of this equipment should adhere to the schedules set -by Seepex Ic. lubricationand procedures are documented in the operation and maintenance manual supplied to TWSA by Inc. These dated September 2010. . _ y Seepex and (c) Belt Press The belt press is a 1.0 meter capacity (model #GRS-1 Series III) as manufactured b Ko The press is located in the bottom of the Lab/Dryer building. All lubricate maintenance of this equipment should adhere to the schedules set b y mline-Sanderson. on and operation and procedures are documented in the operation and maintenance manual supplied toTWSA by Ko Sanderson. y Komline (d) Polymer System The polymer system is a DynaBLEND model # L4S-1200-3P-13-3(D&) supplied b Fluid D PUMP is located in a corner of the dryer/press building adjacent to the belt press. All lubrication Dynamics. The operation and maintenance of this equipment should adhere to the schedules set by Fluid Dynamics. and These procedures are documented in the operation and maintenance manual anual supplied to TWSA by Fluid (e) Sludge Conveyors Information on screw conveyors and components can be found in the Fenton 0 eration P and Maintenance Manual. (f) Sludge Storage Hopper The sludge storage hopper is located between the belt press and the sludge dryer and is used for storing dewatered sludge in preparation for batching to the dryer. (g) Burner The,thermal fluid heater is manufactured. by Fulton and is located adjacent to the dryer in the dryer/press building. Complete technical specifications and operation and maintenance information can be found in Volume 4 of the owner manuals supplied by Fenton to TWSA. (h) Dryer The dryer is a Fenix'48/10 manufactured by Fenton Environmental Technologies and is located in the dryer/press building. Complete operation and maintenance information, can be found in the four (4) volume set supplied to TWSA by Fenton Environmental Technologies. (1) Silo and Baghouse system The Silo and Baghouse were manufactured and supplied to Fenton Environmental by GMD Environmental Technologies of Fort Worth, Texas. Complete operation and maintenance information can be found in volume three (3) of the four (4) volume set supplied to TWSA by Fenton Environmental Technologies. Belt Press Operations • The belt press augers should be turned on and allowed to run. Controls for these augers are _. accessed through the Allen Bradley Panel View Plus 1000 touch screen dryer panel. • Turn control power on at the belt press panel. After a delay -the alarm will sound. Hit reset button to silence the alarm. Pull on the washwater pump, hydraulic pump and belt switch in that order. Confirm that all equipmentis operating properly. • Turn polymer pump on at the DynaFlow pump control panel. Speed of the pump will be adjusted based upon observations made at the press. • Turn sludge pump on by pulling the sludge pump button on the belt filter control panel. Pump feed rate is adjusted at the SPACP 550 panel located on the concrete column adjacent to the belt press. When the polymer begins to form a good floc in the sludge, close valve on mixing tank and write flow reading down on flow meter. Polymer feed rate and sludge feed rate should be adjusted to contain all of the product in the pressure zone of the belt and to produce the driest cake possible and still "turn loose" from the belt at the scraper above the auger. • At the end of the shift or days run, reverse the start up procedure to shut down the press. The daily log sheet has spaces for recording the ,hours operated and gallons of sludge. dewatered. Care should be taken to properly fill out all information so operations can be properly tracked. • When it becomes necessary to change out a drum of polymer it.is important to note the change and the flow reading on the daily sheet. This info is used to calculate dewatering costs. s` Dryer Operation A Dryer controls are all contained in the Allen Bradley Panel View Plus 1000 panel .'Each day the dryer is operated a Dryer. Operations Daily Record should be completed. Dryer operations should be conducted as follows: • Dryer should be set to auto on touch panel screen. Record start time. Burner will activate and start building temperature. When a pre -determined temperature is reached fill cycle will start. • Record fill cycle start time. • After the timed fill cycle is complete, dry cycle will start. Record dry cycle start time. • Dry cycle timer will be on zero at dry cycle start time. Record temperatures as outlined on Daily Record at 50 min intervals until end of dry cycle. (Approx. 200 miss) • At the end of the dry cycle, the discharge cycle will start. Discharge cycle will last approx. 10 min and a new fill cycle will start. • When the last batch of sludge to be dried for the day is in the dryer, set control mode to Automatic Cool Down. This will prevent another batch from being loaded to the dryer and at the end of the cycle the dryer will go into cool down mode in preparation of shutting down. Silo and Baghouse Operation. ' The controls of the baghouse should be set to auto on the panel adjacent to the silo. When the dryer discharges a batch to the silo the baghouse blower will automatically come on and keep dust from being discharged to the atmosphere. Periodic cleaning of the dust bin on the baghouse is required, this is accomplished by placing the backhoe bucket under the chute and opening the slide gate to allow dust to slide into the bucket. Some tapping on the side of the hopper with a rubber mallet may be required - to loosen the accumulated dust. Yti sampling Procedures Daily sampling should be conducted in various points throughout the process to track and verify compliance with permitted values. At least once per day a sample of the raw sludge feed to the belt press should be taken. This sample should be a composite of several samples t.aken at different times during the day. This sample should be obtained from the sample port at the intake to the raw sludge pump in the basement of the reuse water/sludge pump building. This sample should be kept in a container with an air tight lid until analyzed to prevent evaporation. At least once per day a sample of the dewatered sludge cake should be taken from the belt filter press. This sample should.be a composite of several samples taken at different times during the day. This sample should be kept in a container with an air tight lid until analyzed to prevent evaporation. Each batch of sludge discharged from the dryer should be sampled. This sample can be obtained after the discharge of each batch from the sampling port on the side of the discharge auger. This sample is hot when first obtained from the auger and should be allowed, to cool before being bagged. • All of the above samples should be weighed and dried overnight in order to obtain total % solids values. Operators will be provided training in the proper procedures for sampling, storage and analysis of samples before they are expected to conduct analysis. Truck Loading Operations Trucks to be loaded with bioresidual should pull through under the silo. Drivers will be responsible for positioning of their trucks and plant operators will be responsible for loading operations. The storage silo control panel is located at the top of the stairs on the silo. This should be switched to the on position to enable the dust collector blower and chute controls to work. The valve on the green air piping theThe operator should lower the end of the chute to the bed of the truck and then switch on the rotary valve dispenser. The shorter distance residuals have to fall from the end of the chute to the bed of the truck dramatically lessens the amount of dust escaping during the loading process. Paperwork • All users of the bioresiduals must sign and date a Utilization Agreement before taking or possessing the product. This agreement between TWSA and the end user must be signed and dated within one year by both parties. • The hauler or transporter should be given a copy of the signed shipping manifest. The manifest should include an estimated tonnage and should list contact info for the generator and the user along with contact info on the trucking company with places for the generator, hauler and end user to sign. Info as to the proper procedures and safeguards should an accident or spill occur should be included on the manifest. Utilization Agreement a. By signature and agreeing to accept the bulk class A residuals it is recognized that the application of Class A residuals is allowed under the conditions of this agreement. The application of these Class A residuals is considered the beneficial reuse of a waste under 15A NCAC 02T.1100. The application of these Class A Residuals to the land has been deemed permitted under 15A NCAC.1103 (4) provided the conditions of this agreement are met. Any action resulting in the damages to surface waters or groundwater caused by failure to follow the conditions of the agreement is subject to enforcement action by the NC Division of Water Quality. b. The person or entity accepting the Class A residuals shall to the best of their knowledge meet the following application requirements: i. Application of the bulk residuals will stop if it becomes known that the application adversely affects a threatened or endangered species listed under section 4 of the Endangered Species Act or its designated critical habitat. ii. Application of the bulk residuals shall not occur when the land is flooded, frozen, or snow-covered or is otherwise in a condition such that runoff of the residuals would occur. iii. Application of the bulk residuals within the 100 tear flood elevation unless the bulk residuals are injected or incorporated within a 24-hour period following the residuals land application event. Flood elevation information is available at hiip://www.iiefloodmqps.coi-n/default swf asp, - iv. Application of the bulk residuals shall not occur during a measurable precipitation event (Le. > .01" per hour) or within 24 hours following a rainfall event of 0.5 inches or greater in a 24 hour period; V. Residuals stockpiled for more than. 14 days shall be covered. vi. Application of bulk residuals shall not occur if the vertical separation of the seasonal high water table and the bulk residuals application is less than one foot. vii. Application of bulk residuals shall not occur if the vertical separation of the depth to bedrock and the depth "of residuals application is less than one foot. viii. Application of bulk residuals shall not occur within 100 feet of a public or private water supply source; ix. Application of bulk residuals shall not occur within 100 feet of any well with the exception of monitoring wells; x. Application of bulk residuals shall not occur within 25 feet of surface waters. xi. Application of bulk residuals shall not occur if the application causes prolonged nuisance conditions. xii. Application of bulk residuals shall not occur if the land fails to assimilate the bulk residuals or the application causes the contravention of surface water or groundwater standards. F -,- xiii. Application of bulk residuals shall not occur if the slope for land is greater than 10 percent when bulk residuals are surface applied and if the slope of the land is greater than 18 percent when the bulk residuals are injected or incorporated; xiiii. Application of bulk residuals shall not occur if the pH is not maintained in the soil, residuals, and lime mixture, greater than 6.0; on land application sites onto which residuals are applied. Residuals may be applied to these sites provided that a sufficient amount of lime is also applied to achieve a final pH of the soil mixture of at least 6.0, or if an agronomist provides information indicating that the pH of the soil, residuals, and lime mixture is suited for the specified crop type. xv. If the land does not have an established vegetative cover in accordance with the crop management plan outlined by the local Cooperative Extension Office, the Department of Agriculture and Consumer Services, the Natural Resource Conservation Service, or other agronomist unless the bulk residuals are incorporated within a 24-hour period following the residuals application event or injected. 07 The generator of the bulk residuals shall provide information on the proper use of the residuals including information on the nutrient quantities within the residuals and recommended application rates. A copy of the label or information sheet attached to bags or other containers or residuals as specified in condition 111.9. will satisfy this condition. d. The applicator or party receiving bulk residuals from the permittee shall supply all third parties receiving bulk residuals with documentation specifying that application shall occur consistent with the agreement. DInstructions, including contact information for.key personnel, for the applicator or party receiving bulk residuals in the event that requirements specified in the utilization agreement are not met. f. A copy of the utilization agreement shall be maintained at the land application sites when bulk residuals are being applied. g. An education program shall be developed and implemented to inform employees and individuals accepting the residuals of the proper use of residuals. Educational materials shall be provided to all individuals accepting the residuals. The educational material shall be made available to the Division upon request. h. A label shall be affixed should be affixed to the bag or other container in which residuals that are sold or given away for application to the land, and or an information sheet shall be provided to the person who receives the residuals sold or given away in other containers for application to the land. The label or information sheet shall contain the following information: • The name and address of the person who prepared the residuals that is sold or given away in a bag or other container for application to the land. • A statement that application of the residuals to the land is prohibited except in accordance with the instructions on the label or information sheet. • A statement which indentifies that this material shall be prevented from entering any public or private water supply source (including wells) and any stream, lake, or river. • A statement that the residuals shall be applied at agronomic rates and recommended rates for intended uses. Signed: Date for Tuckaseigee Water and Sewer Authority Signed: for Recipient Date Permit: WQ0005763 SOC: County: Jackson Region: Asheville Compliance Inspection Report Effective: 10/08/10 Expiration: 07/31/14 Owner: Tuckaseigee Water & Sewer Authority Effective: Expiration: Facility: Jackson County WWTP 1871 N River Rd Contact Person: Dan Harbaugh Directions to Facility: System Classifications: Primary ORC: Secondary ORC(s): On -Site Representative(s): 24 hour contact name On -site representative Related Permits: 1%3lie Inspection Date: @6PP9f2VTr Primary Inspector: Beverly Price Secondary Inspector(s): Sylva NC 28779 Title: Executive Director Phone: 828-586-5189 Certification: Phone: Stan D Bryson 828-586-9318 Stan D Bryson 828-586-9318 0993© Entry Time: -8 -0M19 Reason for Inspection: Routine Permit Inspection Type: Distribution of Residual. Solids (503) Facility Status: Compliant Not Compliant Question Areas: Miscellaneous Questions Record Keeping Sampling Exit Time: 01:45i M Phone: 828-296-4500 ft� f Inspection Type: mpliance Evaluation (See attachment summary) Ac e d E Treatment �. �'Q Page: 1 Permit: WQ0005763 Owner - Facility: Tuckaseigee Water & Sewer Authority Inspection Date: 06/19/2014 Inspection Type: Compliance Evaluation Reason for Visit: Routine Inspection Summary: This site visit included a tour of the facility. Sludge from the other 3 facilites and WWTP#1 is mixed in the upper aerobic digester. The thickened sludge from the upper digester is sent to the lower digester and mixed/aerated further. From here the sludge goes to the belt -press and then to the dryer. The maintenance/operation logs were good. Dried sludge is stored in the silo. A Non -Hazardous Manifest is filled out each time the hauler comes to pick up residuals. A Spill Control Plan is located on the back of the manifest. Soil Plus, Inc. is currently taking the sludge. Kinsland Trucking out of Whittier, NC is hauling the product for Soil Plus (Scott Carpenter). In addition to the nutrient analysis performed by Tuckaseigee, Mr. Carpenter has the product analyzed for nutrient content by A&L Eastern Labs. Mr. Bryson indicated that he might need to send some product to the landfill to make room in the silo. Page: 2 g :a6ed 3N VN ON saA ❑■❑❑ ❑■❑❑ ❑■❑❑ ❑ E ❑ ❑ ❑■❑❑ ❑■❑❑ ❑❑❑■ ❑ m ❑ ❑ 3N VN ON SBA 3N VN ON SBA �a p� :}ualuluoo Jaglo spae 6ul/',Q lsodwoo (e sselo) uogezillgelS auiliqlb' (V sselo) uoilezunalsed aul1e11d uoilsab(] oigaaeuV uogsebia oigo,aay Aldde legl Ile Noago ;uaw;eajl :}uewwoo 6mopum uoiloulsa�j leuoseaS 6uunp paiin000 uoi;eoildde seH 4sgluow Zl, lsel ui sluieldwoo oilgnd;o aai; uaaq aapplad seH # 691ep-ol-dn pue pauieluiew spjooai 6uilneq ajV 69lgel!ene spJooaJ 6ullneq ajy l.tiewwnS sisRleuV lenplsa�i uo popodai elep lioddns slaags qel oa 600eld ui saoiloeid lenowaj daopuaulnu ajy baps uogeolldde puel aql Jol spJooaJ Hd ajagl ajy 6uogezil!gels aull"ie Jo; SPJ009J Hd ajagl ajV 6paleigleo uaaq luawdinba uogeolldde pue! seH 6sl!wg l!uuad uigl!nn seoueleq NVd aJV 6pauieluiew 6uiaq seoueleq NVcJ aJV 6(sisAleuy /4l pad IIoS piepuelS) b'dSS 'q 6SISAleue dlol -e 4sialaweied 6ulllwll lsow builelolso 6ulpeol lelaw pue luoulnu ajy 691gel!ene slsAleue;uaulnu pue slejew luaiino 9jV balls-uo jpjad luaiino to Adoo a sl 6AI!I!oe; jol palaidwoo woo; uogeoy!IJao V69-ME) sl zsuogeloin fl!lenb ME) Aue ajagl ajy 6sialoweied pa. inbaj lie jol paldwes sMW Ile wal soldwes ME) ajV 6pannbej j! 'polonpuoo 6uiaq 6uuol!uow ME) sl ui aayj PJ030a buila�jeW pue uollnqulsla uoileoilddV puel eugnoa :;ism-'o; uose82l uogenjen3 eoue!ldwoo : odA.L uol;oadsul 14OZ/6V90 :%ep uolpoodsul /411oq;nV jemeS g jejeM a96l9seVnl :Al VB:j - jaumd £9L90000M :Iluuad Permit: WQ0005763 Owner - Facility: Tuckaseigee Water & Sewer Authority Inspection Date: 06/19/2014 Inspection Type: Compliance Evaluation Reason for Visit: Routine Sampling Describe sampling: Total percent solids samples are colleced at the hopper from each batch run from the dyer. Fecal coliform, metals, nutrients and TCLP samples are collected either from the hopper or from the storage silo. Is sampling adequate? Is sampling representative? Comment: Yes No NA NE ■❑❑❑ ■❑❑❑ Page: 4 Compliance Inspection Report Permit: WQ0005763 Effective: 09/11/14 Expiration: 07/31/19 Owner: Tuckaseigee Water & Sewer Authority SOC: Effective: Expiration: Facility: Jackson County WWTP County: Jackson 1871 N River Rd Region: Asheville Sylva NC 28779 ,. Contact Person: Dan Harbaugh Title: Executive Director Phone: 828-586-5189 Ext.203 Directions to Facility: System Classifications: Primary ORC: Secondary ORC(s): On -Site Representative(s): Certification: Phone: 24 hour contact name Stan D Bryson 828-586-9318 Related Permits: NC0063321 Tuckaseigee Water & Sewer Authority - TWSA Plant #3 NC0087602 Tuckaseigee Water & Sewer Authority - Whittier WWTP NC0020214 Tuckaseigee Water & Sewer Authority - TWSA WWTP#2 NC0039578 Tuckaseigee Water & Sewer Authority - Jackson County WWTP Inspection Date: fT8/2017 Entry Time: 03:OOPM Exit Time: 04:OOPM Primary Inspector: Beverly Price Phone: 828-296-4500 Secondary Inspector(s): Reason for Inspection: Routine Permit Inspection Type: Distribution of Residual Solids (503) Facility Status: ❑ Compliant Not Compliant Question Areas: 0 Miscellaneous Questions Record Keeping (See attachment summary) Inspection Type: nnualz eprt Review Pathogen and Vector Attraction Page: 1 9 Permit: W00005763 Owner - Facility: Tuckaseigee Water & Sewer Authority Inspection Date: 12/18/2017 Inspection Type: Annual Report Review Reason for Visit: Routine Inspection Summary The inspection consisted of a review of the 2016 Annual Report. The review was conducted by Beverly Price of the Asheville Regional Office. 54 dry tons of residuals were distributed in 2016. 90.09 tons of residuals were hauled in 2016 by private contractor to: R&B Landfill - operated by Waste Management Inc. 610 Frank Bennett Road Homer Ga. 30080 Residuals were monitored for meta ls/n utrients/TCL P/I g n itabi I ity/Co rros ivity/Reactivity - Analytical results appeared to be compliant with permit conditions. Pathogen Reduction verification via Fecal Coliform Density: requirements were' met. Two fecal coliform samples collected from the silo in November exceeded the limit for Class A residuals. Three additional samples were collected and results were compliant. PathogenNector Attraction Reduction verification via Alternative #5 - Heat Drying - Eight dryer runs appeared to not meet the moisture reduction requirement of 90%. � I e.t S i S� s 6- Vo S©(61S_ 3/k - l3oc� Page: 2 Permit: WQ0005763 Owner - Facility: Tuckaseigee Water & Sewer Authority Inspection Date: 12/18/2017 - Inspection Type: Annual Report Review Reason for visit: Routine Type Land Application Distribution and Marketing Yes No NA NE Record Keeping Yes No NA NE Is GW monitoring being conducted, if required? ❑ ❑ 0 ❑ Are GW samples from all MWs sampled for all required parameters? ❑ ❑ ❑ Are there any GW quality violations? ❑ ❑ ❑ Is GW-59A certification form completed for facility? ❑ ❑ ❑ Is a copy of current permit on -site? ❑ ❑ ❑ Are current metals and nutrient analysis available? E ❑ ❑ ❑ Are nutrient and metal loading calculating most limiting parameters? E ❑ ❑ ❑ a. TCLP analysis? ❑ ❑ ❑ b. SSFA (Standard Soil Fertility Analysis)? ❑ ❑ E ❑ Are PAN balances being maintained? ❑ ❑ E ❑ Are PAN balances within permit limits? ❑ ❑ 0 ❑ Has land application equipment been calibrated? ❑ ❑ ❑ Are there pH records for alkaline stabilization? ❑ ❑ ❑ Are there pH records for the land application site? ❑ ❑ ❑ Are nutrient/crop removal practices in place? ❑ ❑ ❑ Do lab sheets support data reported on Residual Analysis Summary? E ❑ ❑ ❑ Are hauling records available? N ❑ ❑ ❑ Are hauling records maintained and up-to-date? E ❑ ❑ ❑ # Has permittee been free of public complaints in last 12 months? ❑ ❑ ❑ Has application occurred during Seasonal Restriction window? ❑ ❑ N ❑ Comment: 54 dry tons of residuals were distributed to the public in 2016 - hauling records were provided. 90.09 tons of residuals were landfilled in 2016. Hauling tickets were not provided in the Annual Report but are available upon request per Stan Bryson. Pathogen and Vector Attraction Yes No NA NE a. Fecal coliform SM 9221 E (Class A or B) 0 ❑ ❑ ❑ Class A, all test must be <1000 MPN/dry gram Geometric mean of 7 samples per monitoring period for class B<2.0*10E6 CFU/dry gram ❑ Fecal coliform SM 9222 D (Class B only) ❑ 1:10 ❑ Geometric mean of 7 samples per monitoring period for class B<2.0*10E6 CFU/dry gram ❑ b. pH records for alkaline stabilization (Class A) ❑ ❑ E ❑ c. pH records for alkaline stabilization (Class B) ❑ ❑ E ❑ Page: 3 ' Permit: WO0005763 Owner - Facility: Tuckaseigee Water & Sewer Authority Inspection Date: 12/18/2017 Inspection Type: Annual Report Review Reason for Visit: Routine Temperature corrected ❑ d. Salmonella (Class A, all test must be < 3MPN/4 gram day) ❑ ❑ 0 ❑ e. Time/Temp on: ❑ ❑ N❑ Digester (MCRT) ❑ Compost ❑ Class A lime stabilization ❑ f. Volatile Solids Calculations ❑ ❑ N❑ g. Bench -top Aerobic/Anaerobic digestion results 1111 ❑ Comment: Page: 4 Price, Bev From: Satterwhite, Dana Sent: Monday, November 05, 2018 4:49 PM To: Smith, Jason M.; Crawford, Todd; Swanson, Beth Cc: Price, Bev Subject: RE: Fecal Coliform in Sludge Holding Time Clarification The 503 regs are the most outdated convoluted muckity muck I have ever seen. I have implored EPA to clean them up. I agree that the footnote only applies to those methods and Classes of biosolids. Page 70 of the White House book; however, prescribes 24 hours for SM 9221E and 9222 D but references the 1992 SM Compendium. I am curious if Bev has an EPA contact she could get a ruling from? D Dana Satterwhite Environmental Program Supervisor III VW1//GW Laboratory Certification Branch North Carolina Department of Environmental Quality/Division of Water Resources 919 733 3908 ext. 202 office dana.satterwhite(o)-ncdenr.Qov Water Sciences Section 1623 Mail Service Center Raleigh, NC 27699-1623 s' nothing Compares. _,._� Email correspondence to and from this address is subject to the North Carolina Public Records Law and may be disclosed to third parties. Have you signed up to receive automatic email notices of changes to policies, regulations and resources pertaining to the NC Wastewater/Groundwater Laboratory Certification program that could have an impact on your day-to-day operations? If not, send a blank email to the following address: DENR.DWQ.Lab Cert-ioin@lists.ncmail.net From: Smith, Jason M. Sent: Monday, November 05, 2018 11:54 AM To: Satterwhite, Dana <dana.satterwhite@ncdenr.gov>; Crawford, Todd <todd.crawford@ncdenr.gov>; Swanson, Beth <beth. swa nso n @ n cde n r.gov> Cc: Price, Bev <bev.price@ncdenr.gov>; Smith, Jason M. <jason.m.smith@ncdenr.gov> Subject: Fecal Coliform in Sludge Holding Time Clarification Hey guys. Bev Price, who deals with residuals (sludge) in our office brought this question to me. 40 CFR 136.6 Table II, Footnote 23 states: For fecal coliform samples for sewage sludge (biosolids) only, the holding time is extended to 24 hours for the following sample types using either EPA Method 1680 (LTB—EC) or 1681 (A-1): Class A composted, Class B aerobically digested, and Class B anaerobically digested. So Bev's question is, does this mean that the 24 hour holding time does not apply to sludge treated by other methods (e.g., dryers, lime stabilization, etc.). Would a sludge treated by a method not listed be required to be analyzed within 8 hours? Bev also showed me this - https://19ianuarV2017snapshot.epa.gov/sites/production/files/2015- 06/documents/biosoIids htstudy final 2006.pdf Take a look at that and scroll down to page 20 of the overall pdf, which is page 10 of the report, for the study results. For the three options that 40 CFR says are allowed a 24 hour holding time, it says that there are no significant differences when extending the holding time. It says that there are significant differences for the other sludge treatment methods (dryer, lime stabilization, etc.). So it appears that this study is what the footnote in 40 CFR is based upon. One other question would be, is the 24 hour holding time only applicable when EPA methods 1680 or 1681 are used? Because we also allow a 24 hour holding time for SM 9221 C E-2006 (which is essentially equivalent to EPA 1680) and SM 9222 D-2006. So what do you guys think? I want to say that we have discussed this as a group before, but I couldn't find any emails. Jason Smith Chemist II WW/GW Laboratory Certification Branch Department of Environmental Quality/ Division of Water Resources (828)296-4679 iason.m.smith(D,ncdenr.gov Water Sciences Section 2090 US Highway 70 Swannanoa, NC 28778 -�Nothing Compares. — Email correspondence to and from this address is subject to the North Carolina Public Records Law and may be disclosed to third parties. Have you signed up to receive automatic email notices of changes to policies, regulations and resources pertaining to the NC Wastewater/Groundwater Laboratory Certification program that could have an impact on your day-to-day operations? If not send a blank email to the following address: DENR.DWQ.Lab--Cert-join@Iists.ncmail.net DocuSign Envelope ID: E29416A5-FF92-4DEA-8B76-75EE30C6E388 �46VMOHME4iAicuter March 13, 2018 Dan Harbaugh Tuckaseigee Water & Sewer Authority 1246 W Main St Sylva, NC 28779 SUBJECT: NOTICE OF DEFICIENCY Tracking Number: NOD-2018-PC-0115 Annual Report (2016) Review Permit No. WQ0005763 Jackson County WWTP Jackson County Dear Permittee: " COOPER ;Gov`sn�r.: t IND�CUiPEPPER' . �B�l7ft ZT�&C>"OT The North Carolina Division of Water Resources conducted an inspection of the Jackson County WWTP on December 18, 2017. This inspection was conducted to verify that the facility is operating in compliance with the conditions and limitations specified in Non -discharge Permit No. WQ0005763. A summary of the findings and comments noted during the inspection are provided in the enclosed copy of the inspection report. The Annual Report Review inspection was conducted by Division of Water Resources staff from the Asheville Regional Office. The following deficiency(s) was noted during the inspection: Inspection Area Description of Deficiency Pathogen and Vector Attraction Alternative 5 - PFRP - Heat Drying - 90% moisture reduction requirement not met on 8 separate sampling events. Remedial actions should have already been taken to correct this problem and prevent further occurrences in the future. The Division of Water Resources may pursue enforcement action for this and any additional violations of State law. To prevent further action, carefully review these deficiencies and address the causes of non-compliance to prevent the recurrence of similar situations. State of North Carolina I Environmental Quality I Water Resources 2090 U.S. 70 Highway, Swannanoa, NC 28778 828-296-4500 DocuSign Envelope ID: E29416A5-FF92-4DEA-8B7Q-75EE30C6E388 If you should have any questions, please do not hesitate to contact Beverly Price with the Water Quality Regional Operations Section in the Asheville Regional Office at 828-296-4500. Sincerely, DocuSigned by: I er �,1- G. Landon Davidson, P.G., Regional Supervisor Water Quality Regional Operations Section Asheville Regional Office Division of Water Resources, NCDEQ ATTACHMENTS: Inspection Report Ec: Stan Bryson WQS ARO Server LF 20180313_WQ0005763_NOD2018PCO115.rtf State of North Carolina I Environmental Quality I Water Resources 2090 U.S. 70 Highway, Swannanoa, NC 28778 828-296-4500 DocuSign Envelope ID: E29416A5-FF92-4DEA-8B76-75EE3OC6E388 Compliance Inspection Report Permit: WQ0005763 Effective: 09/11/14 Expiration: 07/31/19 Owner: Tuckaseigee Water & Sewer Authority SOC: Effective: Expiration: _ Facility: Jackson County WWTP County: Jackson 1871 N River Rd Region: Asheville Sylva NC 28779 Contact Person: Dan Harbaugh Title: Executive Director Phone: 828-586-5189 Ext.203 Directions to Facility: System Classifications: Primary ORC: Certification: Phone: Secondary ORC(s): On -Site Representative(s): 24 hour contact name Stan D Bryson 828-586-9318 Related Permits: NCO063321 Tuckaseigee Water & Sewer Authority - TWSA Plant #3 NCO087602 Tuckaseigee Water & Sewer Authority - Whittier WWTP NCO020214 Tuckaseigee Water & Sewer Authority - TWSA WWTP#2 NCO039578 Tuckaseigee Water & Sewer Authority - Jackson County WWTP Inspection Date: 12/18/2017 pfntry Time: 03:OOPM Exit Time: 04:OOPM Primary Inspector: Beverly Price �/ Phone: 828-296-4500 Secondary Inspector(s): Reason for Inspection: Routine Permit Inspection Type: Distribution of Residual Solids (503) Facility Status: ❑ Compliant E Not Compliant Question Areas: Miscellaneous Questions Record Keeping (See attachment summary) Inspection Type: Annual Report Review Pathogen and Vector Attraction Page: 1 DocuSign Envelope ID: E29416A5-FF92-4DEA-8B76-75EE30C6E388 Permit: WQ0005763 Owner - Facility: Tuckaseigee Water & Sewer Authority Inspection Date: 12/18/2017 Inspection Type: Annual Report Review Reason for Visit: Routine Inspection Summary: The inspection consisted of a review of the 2016 Annual Report. The review was conducted by Beverly Price of the Asheville Regional Office. 54 dry tons of residuals were distributed in 2016. 90.09 tons of residuals were hauled in 2016 by private contractor to: R&B Landfill - operated by Waste Management Inc. 610 Frank Bennett Road Homer Ga. 30080 Residuals were monitored for metals/nutrients/TCLP/Ignitability/Corrosivity/Reactivity -Analytical results appeared to be compliant with permit conditions. Pathogen Reduction verification via Fecal Coliform Density: requirements were met. Two fecal coliform samples collected from the silo in November exceeded the limit for Class A residuals. Three additional samples were collected and results were compliant. PathogenNector Attraction Reduction verification via Alternative #5 - Heat Drying Eight dryer runs appeared to not meet the moisture reduction requirement of 90%. Page: 2 DocuSign Envelope ID: E29416A5-FF92-4DEA-8B76-75EE30C6E388 Permit: W00005763 Owner - Facility: Tuckaseigee Water & Sewer Authority Inspection Date: 12/1812017 Inspection Type: Annual Report Review Reason for Visit: Routine Twe Land Application Distribution and Marketing Yes No NA NE Record Keeping Yes No NA NE Is GW monitoring being conducted, if required? ❑ ❑ N ❑ Are GW samples from all MWs sampled for all required parameters? ❑ ❑ ❑ Are there any GW quality violations? ❑ ❑ ❑ Is GW-59A certification form completed for facility? ❑ ❑ ❑ Is a copy of current permit on -site? ❑ ❑ ❑ Are current metals and nutrient analysis available? ❑ ❑ ❑ Are nutrient and metal loading calculating most limiting parameters? 0 ❑ ❑ ❑ a. TCLP analysis? ❑ ❑ ❑ b. SSFA (Standard Soil Fertility Analysis)? ❑ ❑ ❑ Are PAN balances being maintained? ❑ ❑ 0 ❑ Are PAN balances within permit limits? ❑ ❑ ❑ Has land application equipment been calibrated? ❑ ❑ ❑ Are there pH records for alkaline stabilization? ❑ ❑ ❑ Are there pH records for the land application site? ❑ ❑ ❑ Are nutrient/crop removal practices in place? ❑ ❑ ❑ Do lab sheets support data reported on Residual Analysis Summary? 0 ❑ ❑ ❑ Are hauling records available? 0 ❑ ❑ ❑ Are hauling records maintained and up-to-date? 0 ❑ ❑ ❑ # Has permittee been free of public complaints in last 12 months? ❑ ❑ ❑ Has application occurred during Seasonal Restriction window? ❑ ❑ N ❑ Comment: 54_dry tons of residuals were distributed to the public in 2016 - hauling records were provided. 90.09 tons of residuals were landfilled in 201.6. Hauling tickets were not provided in the Annual Report but are available upon request per Stan Bryson. Pathogen and Vector Attraction Yes No NA NE a. Fecal coliform SM 9221 E (Class A or B) ❑ ❑ ❑ Class A, all test must be <1000 MPN/dry gram Geometric mean of 7 samples per monitoring period for class B<2.0*10E6 CFU/dry gram ❑ Fecal coliform SM 9222 D (Class B only) ❑ ❑ 0 ❑ Geometric mean of 7 samples per monitoring period for class B<2.0*10E6 CFU/dry gram ❑ b. pH records for alkaline stabilization (Class A) ❑ ❑ ❑ c. pH records for alkaline stabilization (Class B) ❑ ❑ 0 ❑ Page: 3 DocuSign Envelope ID: E29416A5-FF92-4DEA-8B76-75EE30C6E388 Permit: WQ0005763 Owner - Facility: Tuckaseigee Water & Sewer Authority Inspection Date: 12/18/2017 Inspection Type: Annual Report Review Reason for Visit: Routine Temperature corrected ❑ d. Salmonella (Class A, all test must be < 3MPN/4 gram day) ❑ 110 ❑ e. Time/Temp on: ❑ ❑ N ❑ Digester (MCRT) ❑ Compost ❑ Class A lime stabilization ❑ f. Volatile Solids Calculations ❑ 1-10 ❑ g. Bench -top Aerobic/Anaerobic digestion results ❑ ❑ N ❑ Comment: Page: 4 TUCKASEIGEE WATER & SEWER AUTHORITY SERVING JACKSON COUNTY 1246 West Main Street Sylva, NC 28779 Phone: (828) 586-5189 • Fax: (828) 631-9089 Mar 28th, 201"8 Ms Bev Price Div. of Water Resources Asheville Regional Office 2090 U.S. 70 Hwy Swannanoa, NC 28788-8211 RECENE® Division of Water Resoureft APR - 2 2011 VftW Qte:tiEty Reglonet Operett m kbeWe Regional office Subject: Notice of Deficiency Permit No. WQ0005763 Class A EQ Residuals Production Facility & Distribution Program Tuckaseigee Water and Sewer Authority Jackson County Dear Ms Price, The Notice of Deficiency (Tracking # NOD-2018-PC-0115) received by TWSA did not state that a written response was required. I felt however that I should point out that I do not believe the sampling events mentioned should be characterized as deficiencies. The regulations state that amounts of sewage sludge greater than 0 but less than 290 -dry metric tons prepared for sale or given away. should be analyzed for pollutant concentrations, pathogen density and vector attraction 1/year. The TWSA analyzes our residuals on a quarterly basis to ensure compliance with regulations and for the safety of our end users. These samples are collected by compositing a sample from the residual storage silo. This sampling is conducted at the end of the drying process and at the end user point. These samples all showed the solids content of the residuals to be >90%. The sampling events cited as NOD's were collected at the end of a daily dryer run to monitor process control and to help maximize efficiency of the dryer. These samples are not intended to verify compliance with Appendix B to Part 503- PFRP as they are not taken at the user end point. After the dryer, residuals are blown via air to the silo. This accomplishes further drying and mixing of the daily residuals with the stored residuals ensures that all residuals meet the >90% solids criteria even if a batch or daily dryer run does not meet the criteria. I know we have had this conservation before and have never answered it to either parties satisfaction. I feel that if I didn't perform monitoring on each batch from the dryer, none of this would be an issue. I can find nowhere in the regulations that requires me to monitor the process daily and it seems that the TWSA is being penalized for being proactive and diligent in monitoring our process. Your thoughts are greatly appreciated. Sincerely, Stan Bryson Wastewater Plant Operations Supt. Tuckaseigee Water and Sewer Auth. xc: Mr. Dan Harbaugh, Executive Director, Tuckaseigee Water and Sewer Authority 7 uj P Annual Report Review Class A Distribution 1. Class A Annual Distribution and Marketing/Surface Disposal Certification Form ® Was a certification form submitted? I &-k n®k- 1 "-61- • Was distribution conducted during the reported ear? 1 01 How many dry tons were distributed? ,S� em s (�, a -A f�us4 ® Were'the distributions within the permitted amount? e Were recipients information listed? s Did it indicate compliance? NO, o Was form complete? Mc m Was it signed by the appropriate people? N® 5 6NeA 2. Monitoring ® Were the analyses conducted at the required frequency? a Were the metals analyses reported on the Residual. Sampling Summary Form? y o Were the results reported in mg/kg? ►/ Were the metals within ceiling concentration permit limits? Y ® Were the metals within monthly average concentration permit limits? Ij o If no, were the lab analyses attached? o Were all the required parameters tested? ® Was TCLP analysis conducted? \) ® Were the TCLP contaminants within regulatory limits? Y 3. Pathogen and Vector Attraction Reduction o Was a signed copy of the P,atiogen and Vector Attraction eduction Form submitted? Y o Did the form i}dicate the period of coverage, the residua'I class, and the pathogen recction alternative and the vector attraction reduction option used? • Was the appropriate documentation to show pathogen and vector attraction reduction included in the report? Was pathogen and vector attraction reduction demonstrated according to 40 CFR Part 503 or 2T? 4. General ® Was the report in the proper format? o Were any parts of the annual report missing? (J 0 • Was the report submitted on time? N� r i c 6 a 4ts t ii j �� � qo-r C`It Pik (��S�r� ���� e /a o/ (p C i o 104-&fJ5 (" n I I Class A Pathogen Review To be Class A, residuals shall meet either fecal coliform density or salmonella density, Fecal coliform density • Was the, sampling conducted at the required frequency? 1 • Were multiple samples taken? 2d7 mpu' J , • Was each sample less than 100�MPN/gram of total solids? 03 rest-4 Or, Sahnbnella density i Was the sampling conducted at the required frequency? • Were multiple samples taken? • Was each sample less than 3 MPN/4 grams of total solids? To be Class A, residuals shall meet one of the following alternatives; Alternative 1- Time/Temperature • Were the residuals maintained for correct time and temperature? • Were logs submitted showing time and temperature? • Were temperatures within range for complete time period? G�, �30®� A-([ ._ 1060 antic Alternative 2 - Alkaline* Treatment • Were logs submitted showing -time and temperature? V • Was the pH raised to 12 or greater and maintained for 72 hours or longer? • Was the temperature 520C (126°F) for 12 hours or longer while the pH was 12 or greater? • Were logs submitted showing time and pH? • Was the temperature corrected to 256C (77°F)? Alternative 3 -Prior Testine for. Enteric Viruses/Viable Hehmnth Ova • Were residuals analyzed prior to the pathogen reduction treatment? • Prior to treatment were, the density of enteric viruses less thai "one Plaque -forming Unit per four grams of total solids; or was the resultant density after pathogen treatment less than one Plaque -forming Unit per four grams of total solid? OR • Prior to treatment were, the density of viable helminth ova less than one per four grams of total solids; or. was the resultant density after pathogen treatment of viable helminth ova less than one, per four grams of total solids? • Were the operating parameters documented to the satisfaction of the Division? ' Alternative 4 -No Prior Testing for Enteric Viruses/Viable Helminth Ova • Was the density of enteric viruses less than one Plaque -forming Unit per four grams of total solids at the time the residuals were prepared for sale or given away? OR Was the density -of viable helminth ova- less than one per four grams of total solids at the time the - residuals were prepared for. sale or given away? Alternative 5 - Process To Further Reduce Pathogens - PFRP Composting - • Were'the within -vessel method or static•aerated pile methods used? ® Was the residuals temperature maintained at 55°C (131 °F) or higher for three consecutive days or longer in the within vessel method or static aerated pile method? OR • . '. Was the windrow composting method used? ' • Was the residuals temperature maintained at .55°C or higher for 15 consecutive days or longer -An the windrow method, and the windrow turned a minimum of five times during this time?. PFRP Heat Dryin_ g . • Was the residuals dried by direct or indirect with hot gases and moisture content of residuals reduced to 10% or lower? $ 40,1s u.;�u i -Io "'o�s��w� .W's • Did.the temperahare of the residuals or the of the wet -bulb temperature of the gas in contact with the residuals as they leave the dryer exceed_ 80°C (17.6°F)? . PFRP Heat Treatment ® Were the residuals liquid during treatment? ® Were the residuals heated to a temperature of 180°C (356T) or higher,'for 30 minutes? PFRP The mo hilic Aerobic Di eg soon �, • Were the residuals liquid•'during treatment? •. Was it an aerobic process with agitation? • Was the mean cell residence time 10 consecutive days. at 55°C (131°F) to 60°C (140°&)`. PFRP Beta Ray irradiation W-ere:residua s radiated with beta ra s at dosa es- of at least 1.0-me grad at room tem stature _ . 1 y g g p _ - [approximately 20°C (68T)]? PFRP Gamma Ray Irradiation Were residuals radiated with gamma rays from certain isotopes, such as Cobalt 60 and Cesium 137; at dosages of at least 1.0 megarad at room temperature [approximately 20°C(68°F)]? PFRP Pasteurization • Was the temperature of the'residuals maintained at 70'C (158°F) for 30 minutes or longer? Vector Attraction Reduction Review o Was the sampling conducted at the required frequency? 3 8 % Volatile Solids Reduction e Was there 38% reduction? o . Were lab sheets/calculations in report? • Was the reduction on volatile solids (not -total solids)? ® Was the samples taken at beginning of digestion process and before application (Inspection)? a Were calculations correct? 40-Day Bench Scale Test ® Were residuals from anaerobically digested treatment (Inspection)? ® Were residuals anaerobically digested in lab? o Was the test run for 40 days? . ® Was the test done between 30°C (86T) and 37°C (99°F)? ® Was the reduction on volatile solids (not total solids)? © Was the reduction less than 17%? • Were lab sheets/calculations in report? Were calculations correct? 30-Day Bench Scale Test ® Were residuals from aerobically digested treatment (Inspection)?." • Were residuals aerobically digested in lab? s Were residuals 2% or less total solids? • Was the test run for 30 days? o Was the test done at 200C (680F)? • Was the reduction on volatile solids (not total solids)? a Was the reduction less than 15%?. • Were lab sheets/calculations. in report? • Were calculations correct? Specific Oxygen Uptake Rate (SOUR) • Were residuals from aerobically digested treatment (Inspection)? • Were residuals 2% or less total solids (dry weight basis) (not diluted)? • Was the test done between 10°C (50T) and 30°C (86T)? • Was the temperature corrected to 200C (68°F)? • Was the'SOUR equal to or less than 1.5 mg of oxygen per hour per gram of total residual solids (dry weight basis)? • Was the sample holding time under two hours? • Was the test started within15 minutes of sampling or aeration maintained? 14-DE Aerobic Process o Were residuals from aerobically digested treatment (Inspection)? Were the residuals treated for 14 days? Was the residuals temperature higher than 400C (1040F) for the 1-4-day period? Was the average residuals temperature higher than.45°C (I13°F)? Alkaline Stabilization Was the pH of the residuals raised to 12 or higher by the addition of alkali? a Did the pH of residuals remain at 12 or higher for two hours without the addition of more alkali? e Did the pH of residuals remain at 11.5 or higher -for an additional twenty-two hours without the addition of more alkali? o Was the pH. corrected to 250C (770F)? Drying of Stabilized Residuals e Does the residuals contain any unstabilized residuals? e Were the residuals mixed with any other materials? Were the residuals dried to 75% total solids? Drying of Unstabilized Residuals ® Were the residuals mixed with any other materials? 06 e Were the residuals dried to 90% total solids? . �eV2%l' k,a. c ,�S CW 10 (AeA I0 0/ 0 Inj ection Was there any significant. amount of residuals on land surface one hour after injection (Inspection)? m Was injection done on pasture or hay field? Was injection done at time that crop was growing? o If Class A with respect to pathogen, were residuals injected within eight hours after discharge from pathogen treatment? Incorporation ® Were the residuals incorporated into the soil within six hours after application? Was incorporation done on pasture or hay field? ® Was incorporation done at. time that crop was growing? e If Class A with respect to pathogen, were residuals incorporated within eight -------hours-after--discharge�or-r�pat-hogen-tr-eatment?-----------_— ____ W.,` (DtAJ4,-:' t4htp, e)Oill I Cw>t% B- p Annual Report Review Class. A Distribution 1. Class A Annual Distribution and Marketing/Surface Disposal Certification Form ; Was a certification form submitted? �(cg • Was distribution conducted during fhe reported "year? Y cS • How many drytons were -distributed? Fo7 1) TI • Were, -the distributions within the permitted amount? y e,5 • Were recipients information listed? Y10 • Did it indicate compliance? yI__f • Was form complete? yts • Was it signed by the appropriate people? ye-5 ,1. 2. Monitoring • Were the analyses. conducted:at the1required frequency? Yes • Were the metals analyses reported on .the Residual Sampling Summary Form? -e-I • Were there-, sults reported in mg/kg?q,5- • Were the metals within ceiling concentration permit limits? a es •, Were the metals within monthly average concentration pernnt limits? y5 • If no, were the lab analyses. attached? • Were all the required parameters tested?le_T • Was. TCLP analysis conducted? �eS tg �eoYPos�(�e� y� • Were the TCLP, contaminants'within regulatory limits? Y 65 3. Pathogen and Vector Attraction Reduction • Was a signed copy of the Pathogen an ector Attraction duction Form submi ted? - �I • Did the form. mdi` to the period of �c&erage� the residua class, and the pathogen redu tion alternative and the vector attractio. reduction option used? • Was the ap priate documentatio�o show pathogen and vector attraction reduction included in the report? Was pathog" en and vector attraction reduction demonstrated according to 40 CFR Part 503 or 2T? 4. General. • . Was the reportin the proper, format? ,V-e-s • Were any parts of the annual report missing? N o • Was the report submitted on time? / elf Class A Pathosten Review To be Class A, residuals shall meet either fecal coliform density or salmonella density. Fecal coliform density • Was the sampling conducted at the required frequency? YZJ' • Were multiple samples taken? V� • Was each sample less than 1000 MPN/gram of total solids? IJb Or. Salmonella density • Was the sampling conducted at the required frequency? • Were multiple samples taken? • Was each sample less than 3 MPNA grams of total solids? To be Class A, residuals shall meet one of the following alternatives: Alternative 1 - Time/Temperature.. • Were the residuals maintained for correct time and temperature? • Were logs submitted showing time and temperature? • Were temperatures within range for complete time period? Alternative 2 - Alkaline Treatment • Were logs submitted showing time and temperature? • Was the pH raised to 12 or greater and maintained for 72 hours or longer? • Was the temperature 520C (126°F) for 12 hours or longer while the pH was 12 or greater? • Were logs submitted showing time and pH? • Was the temperature corrected to 25°C (770F)? Alternative 3 -Prior Testing for. Enteric Viruses/Viable Helminth Ova • Were residuals analyzed prior to the pathogen reduction treatment? • Prior to treatment were, the density of enteric viruses less than one Plaque -forming Unit per four grams of total solids; or was the resultant density after pathogen treatment less than one Plaque -forming Unit per four grams of total solid? OR - • Prior to treatment were, the density of viable helminth ova less than one per four grams of total solids; or was the resultant density after pathogen treatment of viable helminth ova less than one per four grams of total solids? • Were the operating parameters documented to the satisfaction of the Division? Alternative 4 No Prior Testing for Enteric Viruses/Viable Helminth Ova • Was the density of enteric viruses less than one Plaque -forming Unit per four grams of total solids at the time the residuals were prepared for sale or given away? OR • Was the density .of viable helminth ova- less than one per four grams of total solids at the time the residuals were prepared for. sale or given away? Alternative 5 - Process To Further Reduce Pathogens PFRP Compostirig • Were the within -vessel method or static -aerated pile methods used? Was the residuals temperature maintained at 55°C (131°F) or higher for three consecutive days or longer in the within -vessel method or static aerated pile method? OR Was the windrow composting method used? Was the residuals temperature maintained at 55°C or higher for 15 consecutive days or longer in the windrow method, and the windrow turned a minimum of five times during this time? PFRP Heat Dr nng • Was the residuals dried by direct or indirect with hot gases and moisture content of residuals reduced to 10%or lower? yam' - • . Did -the temperature of the residuals or the of the wet bulb temperature of the gas in contact with the residuals as they leave the dryer exceed 80°C (176°F)?�f PFRP Heat Treatment • Were the residuals liquid during treatment? • Were the residuals heated to a temperature of 180°C (3560F) or higher, for 30 minutes? PFRP Thermophilic Aerobic Digestion_ • Were the residuals liquidduring treatment? •. Was it an aerobic process with agitation? • Was the mean cell residence time 10 consecutive days. at 55°C (13IT) to 60°C (1400F)? PFRP Beta Ray Irradiation • Were residuals radiated with beta rays at dosages -of at least 1.0 megarad at room temperature [approximately 20°C (68°F)]? PFRP Gamma Ray Irradiation • Were residuals radiated with gamma rays from certain isotopes, such as Cobalt 60 and Cesium 137; at dosages of at least 1.0 megarad at room•temperature [approximately 20°C-(68°F)]? PFRP Pasteurization . . Was the temperature of the residuals maintained at 70°C (158°F) for 30 minutes or longer? Vector Attraction Reduction Review] • Was the sampling conducted at the required frequency? 38% Volatile Solids Reduction • Was there 38% reduction? • Were lab sheets/calculations in report? • Was the reduction on volatile solids (not -total solids)? • Was the samples taken at beginning of digestion process and before application (Inspection)? • Were calculations correct? 40-Dav Bench Scale Test • Were residuals from anaerobically digested treatment (Inspection)? • Were residuals anaerobically digested in lab? • Was the test ran for 40 days? • Was the test done between 30°C (86T) and 37°C (99T)? • Was the reduction on volatile solids (not total solids)? • Was the reduction less than 17%? • Were lab sheets/calculations in report? • Were calculations correct? 30-Dav Bench Scale Test • Were residuals from aerobically digested treatment (Inspection)? • Were residuals aerobically digested in lab? • Were residuals 2% or less total solids? • Was the test run for 30 days? • Was the test done at 200C (680F)? • Was the reduction on volatile solids (not total solids)? • Was the reduction less than 15%?. • Were lab-sheets/calculations. in report? • Were calculations correct? Specific Oxygen Uptake Rate SOUR) • Were residuals from aerobically digested treatment (Inspection)? • Were residuals 2% or less total solids (dry weight basis) (not diluted)? • Was the test done between 10°C (50T) and 30°C (86°F)? • Was the temperature corrected to 20°C (68T)? • Was the -SOUR equal to or less than 1.5 mg of oxygen per hour per gram of total residual solids (dry weight basis)? • Was the. sample holding time under two hours? © Was the test started withinl5 minutes of sampling or aeration maintained? 14-Dgy Aerobic Process • Were residuals from aerobically digested treatment (Inspection)? • Were the residuals treated for 14 days? • Was the residuals temperature higher than 400C (104°F) for the 14-day period? • Was the average residuals temperature higher than.450C (1130F)? Alkaline Stabilization E • Was the pH of the residuals raised to 12 or higher by the addition of alkali? • Did the pH of residuals remain at 12 or higher for two hours without the addition of more alkali? • Did the pH of residuals remain at 11.5 or higher for an additional twenty-two hours without the addition of more alkali? • Was the pH corrected to 250C (770F)? DryinaLof Stabilized Residuals • Does the residuals contain any unstabilized residuals? M o • Were the residuals mixed with any other materials? N • Were the residuals dried to 75% total solids? V$ Drying of Unstabili ed Residuals ����r�i�^`> • Were the residuals mixed with any Aer mate'rifals? OC, • Were the residuals dried to 90%-total solids? �S Y ! 50 PkV S�0,0 o ueed +3 u-se- d&A; _ Injection �A" �� W • Was there any significant.amount of residuals on land surface one hour after ��p injection (Inspection)? a K �Vo.� cU A • Was injection done on pasture or hay field? p,4.}-� IV g p • Was injection.done at time that crop was growing? , t • If Class A with respect to pathogen, were residuals injected within eight hours {I/1AJ\J-,Stw1A after discharge from pathogen treatment?o.� CA_ Incorporation OA. • Were the residuals incorporated into the soil within six hours after application? • Was incorporation done on pasture or hay field? • Was incorporation done at time that crop was growing? • If Class A with respect to pathogen, were residuals incorporated within eight -------herttr-sifter-dlsEliarge--pathogen-�eairnent�_.— Price, Bev From: Hardee, Ed Sent: Thursday, August 27, 2015 8:41 AM To: Price, Bev Subject: Sampling This may help from Whitehouse, EPA/625/R-92/013 page 85. Chapter 10 Meeting the Quantitative Requirements of the Regulation Percent Solids Greater Than or Equal to 75% and 90% The monitoring requirement for these vector attraction options (see Sections 8.8 and 8.9) is simply measurement of total solids. This measurement is described in Standard Methods (APHA_[1992], Standard Method 2540 G). Standard Methods states that duplicates should agree within ± 0.5% of their average. For 75% solids, this would be ± 3.8%. For a continuous process, a time -composite sample can be taken over the course of a day, and duplicate analyses carried out on this composite. This is possible because biological activity essentially ceases at high solids content, and decomposition will not occur. Approximately seven such composites over the course of a 2-week sampling period would provide adequate sampling. Some drying processes such as drying sludge on sand drying beds are batch processes. In such cases, it may be desirable to ascertain that the sludge meets the vector attraction reduction requirements before removing the sludge from the drying area. This can be done by taking two separate space -composites from the dried sludge, analyzing each of them in duplicate, and removing the sludge only if it meets the required solids content. Ed Hardee Division of Water Resources Water Quality Permitting Section, Non -Discharge Permitting Unit 1617 Mail Service Center Raleigh, NC 27699-1617 Phone (919) 807-6319 DISCLAIMER: Email correspondence to and from this address is subject to the North Carolina Public Records Law and may be disclosed to third parties unless the content is exempt.by statute or other regulation. Price, Bev From: Hardee, Ed Sent: Tuesday, August 11, 2015 1:27 PM To: Price, Bev Subject: RE: Option 7 VAR ? Correct for VAR. This is for stabilized (treated) residuals. VAR option 8 is for unstabilized.. 15A NCAC 02T .1107 VECTOR ATTRACTION REDUCTION REQUIREMENTS (7) Drying of Stabilized Residuals. The biological residuals shall be dried to 75 percent total solids if the biological residuals contain no unstabilized solids from a primary wastewater treatment process. Mixingof f the biological residuals with other materials shall not be used to meet this alternative. § 503.33 Vector attraction reduction. (7) The percent solids of sewage sludge that does not contain unstabilized solids generated in a primary wastewater treatment process shall be equal to or greater than 75 percent based on the moisture content and total solids prior to mixing with other materials. EPA/625/R-92/013 Environmental Regulations and Technology Control of Pathogens and Vector Attraction in Sewage Sludge 8.8 Option 7: Moisture Reduction of Sewage Sludge Containing No Unstabilized Solids [503.33(b)(7)] Under this option, vector attraction is considered to be reduced if the sewage sludge does not contain unstabilized solids generated during primary wastewater treatment and if the solids content of the sewage sludge is at least 75% before the sewage sludge is mixed with other materials. Thus, the reduction must be achieved by removing water, not by adding inert materials. Ed Hardee Division of Water Resources Water Quality Permitting Section, Non -Discharge Permitting Unit 1617 Mail Service Center Raleigh, NC 27699-1617 Phone (919) 807-6319 DISCLAIMER: Email correspondence to and from this address is subject to the North Carolina Public Records Law and may be disclosed to third parties unless the content is exempt by statute or other regulation. From: Price, Bev Sent: Tuesday,'August 11, 2015 12:50 PM To: Hardee, Ed Subject: -Option 7 VAR ? Hey Ed, My interpretation for 7 is that you are not required to mix with any other materials ... is this correct? Thanks Bev Bev Price - Bev.Price@ncdenr.gov DENR - Division of Water Resources Water Quality Regional Operations Section Asheville Regional Office 2090 U.S. 70 Highway Swannanoa, NC 28778 Tel: 828-296-4500 Fax: 828-299-7043 Notice: E-mail correspondence to and from this address may be subject to the North Carolina Public Records Law and may be disclosed to third parties. Price, Bev From: Hardee, Ed Sent: Monday, August 24, 2015 2:44 PM To: Price, Bev Subject: RE: Heat Drying ?'s Follow Up Flag: Follow up Flag Status: Flagged Bev, This may help from Whitehouse, EPA/625/R-92/013 page 76. Chapter 10 Meeting the Quantitative Requirements of the Regulation 10.2 Process Conditions Sufficient information must be collected about sludge processing conditions and made available to the permitting authority and any other interested parties to enable a qualified reviewer to determine if the Part 503 requirements have been met. How this information is collected and how much information is needed depend on the process. Ed Hardee Division of Water Resources Water Quality Permitting Section, Non -Discharge Permitting Unit 1617 Mail Service Center Raleigh, NC 27699-1617 Phone (919) 807-6319 DISCLAIMER: Email correspondence to and Carolina Public Records Law and may be exempt by statute or other regulation. From: Price, Bev Sent: Monday, August 24, 2015 1:49 PM To: Hardee, Ed Subject: Heat Drying ?'s from this address is subject to the North disclosed to third parties unless the content is Ed, I have a couple of Path/VAR questions if you have time this afternoon. I think it would be easier to talk on the phone than to explain via e-mail. If not today, do you have any time later this week? Bev Bev Price - Bev.Price@ncdenr.gov DENR - Division of Water Resources Water Quality,Regional Operations Section Asheville Regional Office 2090 U.S. 70 Highway Swannanoa, NC 28778 Tel: 828-296-4500 Fax: 828-299-7043 1 Notice: E-mail correspondence to and from this address may be subject to the North Carolina Public Records Law and may be disclosed to third parties. Annual Report Review Class A Distribution 1. Class A Annual Distribution and Marketing/Surface Disposal Certification Form • Was a certification form submitted? 'S • Was distribution conducted during the reported year? ye f • How many dry tons were distributed? f 2.3 , 2._r5 • Were the distributions within the permitted amount? yes • Were recipients information listed? Ygs • Did it indicate compliance? Ye.5' 1 • Was form complete? y cS • Was it signed by the appropriate people? Ics 2. Monitoring • Were the analyses conducted at the required frequency? ye-S • Were the metals analyses reported on the Residual. Sampling Summary Form?y eS • Were the results reported in mg/kg? Its • Were the metals within ceiling concentration permit limits? �es • Were the metals within monthly average concentration permit limits?,ye5 • If no, were the lab analyses attached? • Were all the required parameters tested?.� • Was TCLP analysis conducted? y-d / • Were the TCLP contaminants within regulatory limits?yam M5 Y's 3. Pathogen and Vector Attraction Reduction / • Was a signed copy of the Pathogen andyector Attraction Rouction Form submittedye5 • Did the form indicate the a od of coverage, the residual class, and the pathogen reduction alternative and the vector attraction reduction option used? I/ ,� • Was the aptopriate documentation to show pathogen and vector attraction reduction included in the report? • Was pathogen and vector attraction reduction demonstrated according to 40 CFR Part'503 or 2T? 4. General • Was the report in the proper format?y e.5 • Were any parts of the annual report missing? N n • Was the report submitted on time? its Class A Pathosten Review To be Class A, residuals shall meet either fecal coliform density or salmonella density. Fecal coliform density • Was the sampling conducted at the required frequency? yeS • Were multiple samples taken? Y eS • Was each sample less than 1000 MPN/gram of total solids? ye, Or Salmonella density • Was the sampling conducted at the required frequency? • Were multiple samples taken? • Was each sample less than 3 MPN/4 grams of total solids? To be Class A, residuals shall meet one of the following alternatives: Alternative 1 - Time/Temperature. • Were the residuals maintained for correct time and temperature? • Were logs submitted showing time and temperature? • Were temperatures within range for complete time period? Alternative 2 - A kaline Treatment • Were logs submitted showing time and temperature? • Was the pH raised to 12 or greater and maintained for 72 hours or longer? • Was the temperature 52°C (126°F) for 12 hours or longer while the pH was 12 or greater? • Were logs submitted showing time and pH? • Was the temperature corrected to 250C (770F)? Alternative 3 -Prior Testing for. Enteric Viruses/Viable Helminth Ova • Were residuals analyzed prior to the pathogen reduction treatment? • Prior to treatment were, the density of enteric viruses less than one Plaque -forming Unit per four grams of total solids; or was the resultant density after pathogen treatment less than one Plaque -forming Unit per four grams of total solid? OR - • Prior to treatment were, the density of viable helminth ova less than one per four grams of total solids; or was the resultant density after pathogen treatment of viable helminth ova less than one per four grams of total solids? • Were the operating parameters documented to the satisfaction of the Division? Alternative 4 No Prior TestinLy for Enteric VirusesNiable Hehninth Ova • Was the density of enteric viruses less than one Plaque -forming Unit per four grams of total solids at the time the residuals were prepared for sale or given away? OR • Was the density .of viable helminth ova- less than one per four grams of total solids at the time the residuals were prepared for. sale or given away? Alternative 5 - Process To Further Reduce Pathogens PFRP Composting • Were'the within -vessel method or static -aerated pile methods used? Was the residuals temperature maintained at 55°C (131°F) or higher for three consecutive days or longer in the within -vessel method or static aerated pile method? OR • Was the windrow composting method used? • Was the residuals temperature maintained at 55°C or higher for 15 consecutive days or longer in the windrow method, _and the windrow turned a minimum of five times during this time? PFRP Heat Drying • Was the residuals dried by direct or indirect with hot gases and moisture content of residuals reduced to 10% or lower? y�f • Did.the temperature of the residuals or the of the wet bulb temperature of the gas in contact with the residuals as they leave the dryer exceed 80°C (1760F)? PFRP Heat Treatment • Were the residuals liquid during treatment? • Were the residuals heated to a temperature of 180°C (356°F) or higher, for 30 minutes? PFRP Thermophilic Aerobic Digestion • Were the residuals liquid -during treatment? •. Was it an aerobic process with agitation? • Was the mean cell residence time 10 consecutive days. at 55°C (131°F) to 60°C (140' -� PFRP Beta Ray Irradiation " • Were residuals radiated with beta rays at dosages of at least 1.0 megarad at room temperature [approximately 20°C (680F)]? PFRP Gamma Ray Irradiation • Were residuals radiated with gamma rays from certain isotopes, such as Cobalt 60 and Cesium 137; at dosages of at least 1.0 megarad at room'temperature [approximately 20°C (68°F)]? PFRP Pasteurization . • Was the temperature of the *residuals maintained at 70°C (158°F) for 30 minutes or longer? 4C'5 Vector Attraction Reduction Review • Was the sampling conducted at the required frequency? 38% Volatile Solids Reduction • Was there 38% reduction? • Were lab sheets/calculations in report? • Was the reduction on volatile solids (not total solids)? • Was -the samples taken at beginning of the residuals treatment process and before application (Inspection)? • Were calculations correct? 40-Day Bench Scale Test • Were residuals from anaerobically digested treatment (Inspection)? • Were residuals anaerobically digested in lab? • Was the test run for 40 days? • Was the test done between 30°C (86°F) and 37°C (99°F)? • Was the reduction on volatile solids (not total solids)? • Was the reduction less than 17%? • Were lab sheets/calculations in report? • Were calculations correct? 30-Day Bench Scale Test • Were residuals from aerobically digested treatment (Inspection)? • Were residuals aerobically digested in lab? • Were residuals 2% or less total solids? • Was the test run for 30 days? • Was the test done at 20°C (680F)? • Was the reduction on volatile solids (not total solids)? • Was the reduction less than 15%? • Were lab sheets/calculations in report? • Were calculations correct? (Van Kleeck or mass balance) Specific Oxygen Uptake Rate SOUR) • Were residuals from aerobically digested treatment (Inspection)? • Were residuals 2% or less total solids (dry weight basis) (not diluted)? • Was the test done between 109C (50°F) and 30°C (86°F)? • Was the temperature corrected to 20°C (68°F)? • Was the SOUR equal to or less than 1.5 mg of oxygen per hour per gram of total residual solids (dry weight basis)? • Was the sample holding time under two hours? • Was the test started withinl5 minutes of sampling or aeration maintained? 14-Day Aerobic Process • Were residuals from aerobically digested treatment (Inspection)? • Were the residuals treated for 14 days? • Was the residuals temperature higher than 40°C (104°F) for the 14-day period? • Was the average residuals temperature higher than 45°C (I l3°F)? Alkaline Stabilization • Was the pH of the residuals raised to 12 or higher by the addition of alkali? • Did the pH of residuals remain at 12 or higher for two hours without the addition of more alkali? • Did the pH of residuals remain at 11.5 or higher for an additional twenty-two. hours without the addition of more alkali? • Was the pH corrected to 25°C (77°F)? Drying of Stabilized Residuals • Does the residuals contain any unstabilized residuals? • Were the residuals mixed with any other materials? • Were the residuals dried to 75% total solids? Dr,dnng of Unstabilized Residuals Were the residuals mixed with any other materials? �0 • Were the residuals dried to 90% total solids? �V5 Injection • Was there any significant amount of residuals on land surface one hour after injection (Inspection)? • Was injection done on pasture or hay field? • Was injection done at time that crop was growing? • If Class A with respect to pathogen, were residuals injected within eight hours after discharge from pathogen treatment? Incorporation • Were the residuals incorporated into the soil within six hours after application (Class B)? • Was incorporation done on pasture or hay field? • Was incorporation done at time that crop was growing? • If Class A with respect to pathogen, were residuals incorporated within eight hours after discharge from pathogen treatment? Annual Report Review Class A Distribution Reporting Period: Permit Details: Is 503? Class A or B? Maximum Dry Tons Per Year: Number of acres permitted: Number of fields in permit: Counties that land is permitted for: Monitoring Frequency for TCLP: Monitoring Frequency for Residuals Analysis: Monitoring Frequency for Pathogen & Vector Attraction Reduction: . Class A Annual Distribution and Marketing/Surface Disposal Certification Form Was a certification form submitted? Was distribution conducted during the reported period? How many dry tons were produced and distributed? Were the distributions with the permitted amount? Were recipients information listed? Did it indicate compliance? Was form complete? Was it signed by the appropriate people? 2. Monitoring Were the analyses conducted at the required frequency? Was an analyses taken for each source that was distributed? Were the metals analyses reported on the Residual Sampling Summary Form? Were the results reported in mg/kg? Were the pH's 6.0 or greater for each residual sample? Were the heavy metals within ceiling concentration permit limits? . Were the lab analyses attached? Were all the required parameters tested? Was TCLP analysis conducted? Were the TLCP contaminants within regulatory limits? Was a corrosivity, ignitability, and reactivity analysis conducted? 3.//Pathogen and Vector Attraction Reduction -a ✓W� 'signed copy of the Pathogen and Vector Attraction Reduction Form submitted? --Didsthe form indicate the period of coverage, the residual class, and the pathogen reduction alternative and the vector attraction reduction option used? 'Was the appropriate documentation to show pathogen and vector attraction reduction included m he report? as pathogen and vector attraction reduction demonstrated according to 40 CFR Part 503? Class A Pathogen Review To be Class A, residuals shall meet either fecal Coliform density or salmonella density. Fecal Coliform density Was the sampling conducted at the required frequency? Were multiple samples taken? Was each sample less than 1000 MPN/gram of total solids? •' Salmonella density Was the sampling conducted at the required frequency? Were multiple samples taken? Was each sample less than 3 MPN/4 grams of total solids? To be Class A, residuals shall meet one of the following alternatives: Alternative 1 — Time/Temperature Were the residuals maintained for correct time and temperature? Were logs submitted showing time and temperature? Were temperatures within range for complete time period? Alternative 2 — Alkaline Treatment Were logs submitted showing time and temperature? Was the pH raised to 12 or greater and maintained for 72 hours or longer? Was the temperature 52°C (1267) for 12 hours or longer while the pH was 12 or greater? Were logs submitted showing time and pH? Was the temperature corrected to 25°C (777)? Alternative 5 — Process To Further Reduce Pathogens PFRP Composting Were the within -vessel method or static aerated pile methods used? Was the residuals temperature maintained at 55°C (131°F) or higher for three consecutive days or longer in the within -vessel method or static aerated pile method? OR Was the windrow composting method used? Was the residuals temperature maintained at 55°C or higher for 15 consecutive days or longer in the windrow method, and the windrow turned a minimum of five times during this time? Ptp Heat Drying as the residuals dried by direct or indirect contact with hot gases and the moisture co nt of residuals reduced to 10% or lower? Did the temperature of the residuals or the of the wet bulb temperature of the gas in contact with the residuals as the residuals leave the dryer exceed 80°C (176°F)? Vector Attraction Reduction Review Was the sampling conducted at the required frequency? Option 1 — 3 8% Volatile Solids Reduction Was there 3 8% reduction? Were lab sheets/calculations in report? Was the reduction on volatile solids (not total solids)? • Were the samples taken at beginning of digestion process and before application (Inspection)? • Were calculations correct? Option 2 — 40-Day Bench Scale Test . Were residuals from anaerobically digested treatment (Inspection)? Were residuals anaerobically digested in lab? Was the test run for 40 days? Was the test done between 30°C (86°F) and 37°C (99°F)? Was the reduction of on volatile solids (not total solids)? Was the reduction less than 17%? Were lab sheets/calculations in report? Were calculations correct? Option 3 — 30-Day Bench Scale Test Were residuals from aerobically digested treatment (Inspection)? Were residuals aerobically digested in lab? Were residuals 2% or less total solids? If not 2% total solids, was the test ran on a sample diluted to 2% with unchlorinated effluent? Was the test run for 30 days? Was the test done at 20°C (68°F)? Was the reduction of on volatile solids (not total solids)? Was the reduction less than 15%? Were lab sheets/calculations in report? Were calculations correct? Option 4 — Specific Oxygen Uptake Rate(SOUR) Were residuals form aerobically digested treatment (Inspection)? Were residuals 2% or less total solids (dry weight basis) (not diluted)? Was the test done between 10°C (50°F) and 30°C (86°F)? Was the temperature corrected to 20°C (68°F)? Was the SOUR equal to or less than 1.5 mg of oxygen per hour per gram of total residual solids (dry weight basis)? Was the sampling holding time two hours? Was the test started within 15 minutes of sampling or aeration maintained? Option 5 — 14-Day Aerobic Process Were the residuals from aerobically digested treatment (Inspection)? Were the residuals treated for 14 days? Was the residuals temperature higher than 40°C (104°F) for a 14-day period? Was the average residuals temperature higher than 45°C (113°F)? Option 6 — Alkaline Stabilization Was the pH of the residuals raised to 12 or higher by the addition of alkali? Did the pH of residuals remain at 12 or higher for two hours without the addition of more alkali? • Did the pH of residuals remain at 11.5 or higher for an additional twenty-two hours without the addition of more alkali? Was the pH corrected to 25°C (77°F)9. Option 7 — Drying of Stabilized Residuals Does the residuals contain any unstabilized residuals? Were the residuals mixed with any other materials? Were the residuals dried up to 75% total solids? ttion 8 — Drying of Unstabilized Residuals ��Were the residuals mixed with any other materials? ere the residuals dried to 90% total solids? C,z% 6 Option 9 — Injection • Was there any significant amount of residuals on land surface one hour after injection (Inspection)? Was injection done on pasture or hay field? Was injection done at time that crop was growing? If Class A with respect to pathogen, were residuals injected with eight hours after discharge from pathogen treatment? 4.General Was the report in the proper format? Was the annual report complete? Was the report submitted on time?