HomeMy WebLinkAboutSW3221004_Supplement-EZ Form_20221012SUPPLEMENT-EZ COVER PAGE
FCRM5LOAOEU
PROJECT INFORMATION
1 1 Project Name
Mount Pleasant High School
2
toastal
99,04
3 Wetland Area
4
ISurface Water Area c)
5
lsthisproj_eq "!a pir.L!ow PeLn4!
Low
6
Does this project use an off -site SCM?
No
7- 7-Ndth.of vegetated eetbaqks.provided. (feet)
$--]. Will ,the vegetated setback remain vegetated? N/A
9 1 BUAis proposed in the setback, does it meet NCAC 02H 10ON41(!- 7 N/A
onpr I 0)_
10 Is streambank stabilization proposed on this project? No
NUMBER AND TYPE OF SCM111.1
_11 Infiltration
12 Sioretention Cell
13 Wet Pond
14 StormwaterWetJand
15 Permeable Pavement
is Sand Filter
17 !Rainwater (RWH)
18 Green Roof
-.19 Level- Spjeac!er-fktteLr Stop (LS-FS)
20 Disconnected Surface (DIS)
21 Treatment Swale.---
22 Dry
StormFilter
--23
24 Silva Call
2 5 Bayfil r
26 :Filterra
FORIVISLOADED
28
29 Street address:
....... ... .... ... . ....... . . ......
130 . . City, State, Zip: ....... ....
31 Phone number(s):
32 'Email:
Kevin
Certification Statement:
I certify, under penalty of law that this Supplement-EZ form and all supporting information were prepared under my direction or supervision; that the
information provided in the form is, to the best of my knowledge and belief, true, accurate, and complete; and that the engineering plans, specifications,
operation and maintenance agreements and other supporting information are consistent with the information provided here.
XAGARo
..........
SEAL
20165
GIN
Sjj(naL*e of Designer
/o �s zz
Date
— Corrected
DRAINAGE AREAS
1
Is this a_high density project? _— _
No —
2
If so, number of drainage areas/SCMs
0
3
Does this project have low density areas?
Yes
4
_
If so, number of low density drainage areas
1
5
Is all/part of this project subject to previous rule
versions?
No
FORMS LOADED
DRAINAGE AREA INFORMATION Entire Site LD 1
4
Type of SCM
4,314,143
5
Total drainage area (sq ft
41314143
4,314,143
915514 sf
102500 s_f
6
Onsite drainage area (sq ft)
4,314,143
7
8
Offsite draina ee area
0
iTotal BUA in project (sq ft)
915514 sf
9
10,
New BUA on subdivided lots (subject to permitting)
sq ft)—_ —
New BUA not on subdivided lots (subject to
permitting) (sf) —
T 102500 sf---
11
12
� Offsite BUASsq ft1- _ _
1 Breakdown of new BUA not on subdivided lots:
—
- Parkingisq ft)
_
r
_
- Sidewalk (sq ft) _—
- Roof Ssq ft) _
-
Roadwa -(sq ft) —--------
--
-----
— —
- Future sgfy.._-_ —
- Other, please specify In the comment box
below (sq ft
102500 sf
_-
102500 sf
13
New infiltrating permeable pavement on subdivided
lots ft
14
_
New infiltrating permeable pavement not on
subdivided lots(sq ft)
15
Existing BUA that will remain (not subject to
1 permitting)s ft
813014 sf
813014 sf
16
Existing BUA that is already permitted (sq ft)
17
Existing BUA that will be removed (sq ft
5700 sf _
5700 sf
18
Percent BUA
21 %
21 %
19 Design storm (inches _
20 Design volume of SCM (cu ft)
21 Calculation method for design volume
,ADDITIONAL INFORMATION
Please use this space to provide any additional information about the
22 'drainage area(s):
New synthetic turf field —
1.0 in
LOW DENSITY
DESIGN REQUIREMENTS FOR LOW DENSITY PROJECTS FROM 02H.1003
1 Is project below density thresholds set forth in the applicable stormwater rule? Yes
2 Does project maximize dispersed flow and minimize channelization of flow? Yes
3 Has the use of piping been minimized per.1003(2)(c)?
4 Side slopes of the vegetated conveyances(H:V)
5 Maximum velocity in the vegetated conveyances during the 10-year storm?
6 Are curb outlet swales proposed? No
7 Maximum longitudinal slope of curb outlet swale(s)(%)
8 Bottom width of curb outlet swale(s)(feet)
9 Maximum side slope of curb outlet swale(s)(H:V)
10 Minimum length of curb outlet swale(s)(feet)
11 Are treatment swales used instead of curb outlet swales?
12 Is stormwater released at the edge of the setback as dispersed flow? Yes
13 Have stormwater outlets been designed to prevent downslope erosion? I Yes
14 JAre variations to rule.1003 proposed? No
ADDITIONAL INFORMATION
15 1 Please use this space to provide any additional information about this low density project: