HomeMy WebLinkAboutSW6221002_Supplement-EZ Form_20221006SUPPLEMENT-EZ COVER PAGE
)RMS LOADED
iPROJECT INFORMATION
1_ Project Name
2 _I Project Area (ac)
3_ ICoastal Wetland Area (ac)
4 1Surface Water Area fee)
5 Is this ro ect H h or Low Deatsit ?
6 Does this project use an off -site SCM?
Avonlea Subdivision
21.74
No
COMPLIANCE WITH 02H .10.9,3(R)
7
lWidth of vegetated setbacks provided Ifeet) N/A
lWill the vegetated setback remain vegetated? N/A
8
9
If BUA is proposed in the setback, does it meet NCAC 02H.1003 4 (c-d)? N/A
10
Is streambank stabilization proposed on this project? No
NUMBER AND TYPE OF SCMs:
11 Infiltration System
12
Bioretention Cell
13
Wet Pond 2
14
Stormwater Wetland
15
Permeable Pavement
16
Sand Filter
17
Rainwater Harvesting RWH
18
Green Roof
19
Level Spreader -Filter Strip LS-FS
20
Disconnected Impervious Surface (DIS)
21
Treatment Swale
22
Dry Pond
23
StormFilter
24
Silva Cell
25
Bayfilter
26
Filterra
FORMS LOADED
DESIGNER CERTIFICATION
27
i Name and Title: Donald L. Curry. Jr., PE / Project Manager
28
organization: Curry Engineering
29
Street address: 205 S. Fuguay Ave.
30
_
City, State, Zip: Fu ua-Varina NC 27526
Phone number(s): 919-552-0849
Email: don@curryeng.com
31
32
Certification Statement:
I certify, under penalty of law that this Supplement-EZ form and all supporting information were prepared under my direction or supervision; that the
information provided in the form is, to the best of my knowledge and belief, true, accurate, and complete; and that the engineering plans,
specifications, operation and maintenance agreements and other supporting information are consistent with the information provided here.
ptd P.?�NtC
Seal
COO
Signature of Designer
Date
JtFOP' �. 2-02-2
DRAINAGE AREAS
1 Is this a nigh denser project? Yes
2 If so, number of drainage areaslSCMs 2 _
3 Does this project have low density areas? No _
4 If so, number of low density drainage areas 0
Is allf.part of this project subject to previous rule
5 'versions? L No
FORMS LOADED
DRAINAGE AREA INFORMATION
Entire Site
1
2
4 Toe of SCM
Wet Pond
Wet Pond
Wet Pond
5 Total drainage area (sq ft
801072
528385
272687
6 Onsite drainage area (sq ft
801072
528385
272687
7 Offsite drainage area (sq ft)
0
0
0
8
Total BUA in project sq ft)
455050 sf
286294 sf
168756 sf
9
New BUA on subdivided lots (subject to permitting)
jsq ft)
455050 sf
286294 sf
168756 sf
10permitting)
New BUA not on subdivided lots (subject to
s
sf
sf
sf
11
Offsite BUA (sq ft)
sf
sf
sf
12 Breakdown of new BUA not on subdivided lots:
- Parking (sq ft)
3000 sf
3000 sf
sf
- Sidewalk (sq ft)
31089 sf
17774 sf
13315 sf
- Roof (sq ft)
315000 sf
201000 sf
114000 sf
- Roadway (sq ft)
95961 sf
54520 sf
41441 sf
- Future (sq ft)
sf
sf
sf
- Other, please specify in the comment box below
(sq ft)
sf
10000 sf
6f
jNew
13
infiltrating permeable pavement on subdivided
Ilots s ft
sf
sf
sf
14
New infiltrating permeable pavement not on
subdivided lots (sq ft
sf
sf
sf
15permitting)
Existing BUA that will remain (not subject to
s ft
sf
sf
sf
16
Existing BUA that is already permitted (sq ft)
sf
sf
sf
17
Existin BUA that will be removed (sq ft)
sf
sf
sf
18
Percent BUA
57%
54%
62%
19 IDesign
storm (inches)
1.0 in
1.0 in
1,0 in
20 i Design volume of SCM (cu ft)
40753 cf
25330 cf
15423 cf
21 Calculation method for design volume
Simple
Sim
Simple
Sim le
ADDITIONAL INFORMATION
Please use this space to provide any additional information about the
22 drainage area(s):
Pond #1: 10,000 sf impervious allocated for amenity
WET POND
1 Drainage area number 1 2
62, Minimum 2Mired treatmeht volume cu ft23674 cf 13793 d
ENNERALMOCFROM42H_ M
3
Is the SCM sized to treat the SW from all sw1aces at build -out? Yes
Is the SCM located away from contaminated soils? Yes
Yes
41
Yes
5;
What are the side slopes of the SCM H:V ? 3:1
3:1
6
Does the SCM have retaining walls, gabion walls or other engineered
side slopes? No
No
7i
Are the inlets, outlets, and receiving stream protected from erosion
Yes
10- ear storm)?
Yes
8
Is there an overflow or bypass for inflow volume in excess of the
design volume?
Yes
Yes
9
What is the method for dewatering the SCM for maintenance?
Pump ( refp erred)
Pump (preferred)
10.E
If applicable, will the SCM be cleaned out after construction? I Yes
Yes
11
Does the maintenance access comply with General MDC 8)? Yes
Yes
121
Does the drainage easement comply with General MDC 9)? Yes
Yes
13
If the SCM is on a single family lot, does (will?) the plat comply with No
General MDC (10)?
No
14
Is there an O&M Agreement that complies with General MDC (11)? Yes
Yes
151
Is there an O&M Plan that complies with General MDC (12)? Yes
as
Yes
16 Does the SCM follow the device spec MDC? _ Yes
17 Was the SCM designed an NC licensed rufessitin�il? Yes
Yes
1 B
Sizing method used SA/DA
SA47A
19
Has a sta a/storage table been provided in the calculations? Yes
Yes
167.00
20
Elevation of the excavated main pool depth (bottom of sediment
removal) fmsl
170.50
21
Elevation of the main pool bottom (top of sediment removal) (fmsl) 1 171.50
168.00
22i
Elevation of the bottom of the vegetated shelf (fmsl) 176.00
172.50
231
Elevation of the permanent pool (fmsl) 176.50
173.00
24
Elevation of the top of the vegetated shelf fmsl 177.00
173.50
25
Elevation of the tem oraryool (fmsl) 178.00
174.30
26
Surface area of the main eermanent pool (square feet) 11460
7734
27
Volume of the main permanent pool cubic feet 31572 cf
21812 cf
28
Average depth of the main pool (feet) 3.23 ft
3.28 ft
29
Average depth equation used Equation 3
Equation 3
30 If using equation 3, main pool perimeter (feet) 1 594.0 ft
594.0 ft
31. If using equation 3, width of submerged veg. shelf_ feet 1 3.0 ft
3.0 ft
32[Volume
of the foreba (cubic feet)
1 4882 cf
4070 cf
33
Is this 15-20% of the volume in the mainpool?
1 Yes
Yes
34
Clean -out depth for forebay (inches)
12 in
12 in
35
Design volume of SCM cu ft)
25330 d
15423 d
36
Is the outlet an orifice or a weir?
Orifice
Orifice
37
If orifice, orifice diameter (inches)
2 in
2 in
38
If weir, weir height (inches)
in
In
39
If weir, weir len th (inches
in
in
40
Drawdown time for the tempora ool (days)
3.12
3.37
41
Are the inlet(s) and outlet located in a manner that avoids short-
circuiting? Yes
Yes
42
Are berms or baffles provided to improve the flow ath? No
No
43
Depth of forebay at entrance (inches)
30 in
30 in
44
Depth of forebay at exit (inches)
36 in
36 in
45
Does water flow out of the forebay in a non -erosive manner?
Yes
Yes
461
Width of the vegetated shelf (feet)
6 ft
6 ft
47
Slope of vegetated shelf H:V
6:1
6:1
48
Does the orifice drawdown from below the top surface of the
permanentpool?
Yes
Yes
49
Does the pond minimize impacts to the receiving channel from the 1-
r, 24-hr storm? Yes
Yes
50
Are fountains proposed? (If Y, please provide documentation that
MDC(9) is met.) No
No
51
Is a trash rack or other device provided to protect the outlet system?
Yes
Yes
52
Are the dam and embankment planted in non -clumping turf grass?
Yes
Yes
53
Species of turf that will be used on the dam and embankment
Fescue or
Centipede
Fescue or
Centipede
Yes
54.Has a planting plan beers provJdLd for the v etated shelf? Yes
ADD TiONAL.INFDR[NATION
Please use this space to provide any additional information about the
55wet pand[s]: