Loading...
HomeMy WebLinkAboutSW3221001_Supplement-EZ Form_20221006SUPPLEMENT-EZ COVER PAGE FORMS LOADED OJECT IN RMATION 1 Project Name 2 Project Area (ac) 3 Coastal Wetland Area ac 4 Surface Water Area (ac) 5 Is this project High or Low Density? 6 Does this project use an off -site SCM? Brighton Park 86.77 2.08 High No COMPLIANCE WITH 02H .1003(4) 7 Width of vegetated setbacks provided feet 85 8 Will the vegetated setback remain vegetated? Yes 9 If BUA is proposed in the setback, does it meet NCAC 02H.1003 4 c-d ? N/A 10 Is streambank stabilization proposed on this project? No MBER AND TYPE 11 Infiltration System 12 Bioretention Cell 13 Wet Pond 14 Stormwater Wetland 15 Permeable Pavement 16 Sand Filter 6 17 Rainwater Harvesting RWH 18 JGreen Roof 19 Level S reader -Filter Strip LS-FS 20 Disconnected Impervious Surface DIS 21 Treatment Swale 22 Dry Pond 23 StormFilter 24 Silva Cell 25 Ba filter 26 Filterra FORMS LOADED SIGNER CERTIFICATION 27 Name and Title: Carlos L. Ruano, P.E. 28 Or anization: Latham -Walters Engineering Inc. 29 Street address: 16507-A Nonccross Drive 30 Cit , State, Zip: Huntersville, NC 28078 31 Phone number(s): 704-895-8484 32 Email: carlos@lwengineer.com Certification Statement: I certify, under penalty of law that this Supplement-EZ form and all supporting information were prepared under my direction or supervision, that the information provided in the form is, to the best of my knowledge and belief, true, accurate, and complete, and that the engineering plans, specifications, operation and maintenance agreements and other supporting information are consistent with the information provided here. ,Q"�oESAR0�/2' SEAL S23S6 OS Seal Signature of Designer Date 9/27/2022 J DRAINAGE AREAS 1 Is this a high density project? Yes 2 If so, number of drainage areas/SCMs 6 3 Does this project have low density areas? No 4 If so number of low densit drainage areas 0 5 Is all/part of this project subject to previous rule versions? No FORMS LOADED DRAINAGE AREA INFORMATION Entire Site 1 2 3 4 4 Type of SCM Sand Filter Sand Filter Sand Filter Sand Filter Sand Filter 5 Total drainage area (sq ft 2791325 777982 426888 386377 416434 6 Onsite drainage area (sq ft) 2791325 777982 426888 386377 416434 7 Offsite drainage area (sq ft 0 0 0 0 0 8 Total BUA in project (sq ft) 1268171 390257 sf 178424 sf 176418 sf 186142 sf 9 New BUA on subdivided lots (subject to permitting) (sq ft 843650 225600 sf 133950 sf 122200 sf 126900 sf 10permitting) New BUA not on subdivided lots (subject to s 424406 0 0 164657 sf 44475 sf 54102 sf 59242 sf 11 Offsite BUA (sq ft 12 Breakdown of new BUA not on subdivided lots: Parkin (sq ft 11530 11530 sf Sidewalk (sq ft) 87927 25287 sf 10716 sf 12720 sf 13068 sf Roof (sq ft 8050 8050 sf Roadway s ft 316900 119790 sf 33759 sf 41382 sf 46174 sf Future (sq ft Other, please specify in the comment box below (sq ft 13 New infiltrating permeable pavement on subdivided lots (sq ft 14 New infiltrating permeable pavement not on Isubdivided lots (sq ft 15permitting) Existing BUA that will remain (not subject to s ft 16 Existing BUA that is already permitted (sq ft 17 Existing BUA that will be removed (sq ft 18 Percent BUA 45% 50% 42% 46% 45% 19 Design storm inches 6.0 in 6.0 in 6.0 in 6.0 in 6.0 in 20 Design volume of SCM cu ft 32511 cf 15161 cf 14833 cf 15696 cf 21 1 Calculation method for design volume HydroCAD HydroCAD HydroCAD HydroCAD HydroCAD ADDITIONAL INFORMATION 22 Please use this space to provide any additional information about the drainage area(s): DRAINAGE AREAS 1 Is this a high density project? Yes 2 If so, number of drainage areas/SCMs 6 3 Does this project have low density areas? No 4 If so number of low densit drainage areas 0 5 Is all/part of this project subject to previous rule versions? No FORMS LOADED DRAINAGE AREA INFORMATION Entire Site 5 6 4 Type of SCM Sand Filter Sand Filter Sand Filter 5 Total drainage area (sq ft 2791325 350658 432986 6 Onsite drainage area (sq ft) 2791325 350658 432986 7 Offsite drainage area (sq ft 0 0 0 8 Total BUA in project (sq ft) 1268171 136941 sf 199989 sf 9 New BUA on subdivided lots (subject to permitting) (sq ft 843650 103400 sf 131600 sf 10permitting) New BUA not on subdivided lots (subject to s 424406 0 0 33541 sf 68389 sf 11 Offsite BUA (sq ft 12 Breakdown of new BUA not on subdivided lots: Parkin (sq ft 11530 Sidewalk (sq ft) 87927 8712 sf 17424 sf Roof (sq ft 8050 Roadway s ft 316900 24830 sf 50965 sf Future (sq ft Other, please specify in the comment box below (sq ft 13 New infiltrating permeable pavement on subdivided lots (sq ft 14 New infiltrating permeable pavement not on Isubdivided lots (sq ft 15permitting) Existing BUA that will remain (not subject to s ft 16 Existing BUA that is already permitted (sq ft 17 Existing BUA that will be removed (sq ft 18 Percent BUA 45% 39% 46% 19 Design storm inches 6.0 in 6.0 in 6.0 in 20 Design volume of SCM cu ft 11732 cf 16803 cf 21 Calculation method for design volume HydroCAD HydroCAD HydroCAD ADDITIONAL INFORMATION 22 Please use this space to provide any additional information about the drainage area(s): SAND FILTER 11 Drainage area number 1 2 3 4 5 2 1 Minimum required treatment volume cu ft 24384 sf 11371 sf 11125 sf 11772 sf 8800 sf GENERAL MDC FROM 02H .1050 3 Is the SCM sized to treat the SW from all surfaces at build -out? Yes Y-es Yes Yes Yes 4 Is the SCM located away from contaminated soils? Yes Yes Yes Yes Yes 5 What are the side slopes of the SCM (H:V)? 3:1 3:1 3:1 3:1 3:1 6 Does the SCM have retaining walls, gabion walls or other engineered side slopes? No No No No No 7 Are the inlets, outlets, and receiving stream protected from erosion (10-year storm)? Yes Yes Yes Yes Yes 8 Is there an overflow or bypass for inflow volume in excess of the design volume? Yes Yes Yes Yes Yes 9 What is the method for dewatering the SCM for maintenance? Drawdown Orifice Drawdown Orifice Drawdown Orifice Drawdown Orifice Drawdown Orifice 10 If applicable, will the SCM be cleaned out after construction? Yes Yes Yes Yes Yes 11 Does the maintenance access comply with General MDC (8)? Yes Yes Yes Yes Yes 12 Does the drainage easement comply with General MDC (9)? Yes Yes Yes Yes Yes 13 If the SCM is on a single family lot, does (will?) the plat comply with General MDC (10)? Yes Yes Yes Yes Yes 14 Is there an O&M Agreement that complies with General MDC (11)? Yes Yes Yes Yes Yes 151 Is there an O&M Plan that complies with General MDC (12)? 1 Yes Yes Yes Yes Yes 161 Does the SCM follow the device specific MDC? Yes Yes Yes Yes Yes 17 Was the SCM desi ned bv an NC licensedprofessional? Yes Yes Yes Yes Yes SAND FILTER MDC FROM 02H .1056 18 SHWT elevation (fmsl) N/A N/A N/A 623.71 N/A 19 Type of sand filter (open or closed) Open Open Open Open Open 20 If closed, will the filter will be pre -cast or pour -in -place? N/A N/A N/A N/A N/A 21 If closed, top of grate elevation (fmsl) N/A N/A N/A N/A N/A 22 Is this sand filter designed to attenuate peak flows? Yes Yes Yes Yes Yes I Sediment Chamber 23 Volume that can be retained in the sediment chamber (cubic feet) 18600 cf 12128 cf 9906 cf no 628.00 12508 cf no 631.00 7674 cf no 613.00 24 Will there be a permanent pool in the sediment chamber? no 609.00 no 634.00 25 Bottom of the sediment chamber (fmsl) 26 Area of the sediment chamber (square feet 9300 sf 6064 sf 4953 sf 6254 sf 3837 sf 27 Physical depth of the sediment chamber (inches) 24 in 24 in 24 in 24 in 24 in 28 Ponding depth in the sediment chamber, above any permanent pool inches Elevation of top of weir between chambers (fmsl) 24 in 24 in 24 in 24 in 24 in 29 611 636 630 633 615 Sand Chamber 30 Volume that can be retained in the sand chamber (cubic feet) 8700 cf 4350 cf 7400 cf 5027 cf 5896 cf 31 Bottom of the sand chamber (fmsl) 607.50 632.50 626.50 629.50 611.50 32 Area of the sand chamber (square feet) 2640 sf 1415 sf 1360 sf 1440 sf 1095 sf 33 Physical de th of the sand chamber inches 18 in 18 in 18 in 18 in 18 in 34 Ponding depth in the sand chamber, above the sand surface (inches) 24 in 18 in 18 in 24 in 24 in 351 Elevation of the bypass device (fmsl) 615 639 633 637 618.5 36 Type of bypass device Spillway Spillway Spillway Spillway Spillway 37 Mechanism for distributing flow over the sand surface Riprap Riprap Riprap Riprap Riprap 38 Sand specification for sand chamber ASTM C33 ASTM C33 ASTM C33 ASTM C33 ASTM C33 39 Depth above underdrain pipe (inches) 6 in 6 in 6 in 6 in 6 in 40 Will the media be maintained to drain at least two inches per hour at the sand surface? Yes Yes Yes Yes Yes 41 Is at least one clean -out pipe provided at the low point of each underdrain line? Yes Yes Yes Yes Yes 42 Will clean -out pipes be capped? I Yes I Yes I Yes Yes Yes Sand Filter 4 3:29 PM 9/27/2022 SAND FILTER 1 Drainage area number 6 2 Minimum required treatment volume cu ft 12603 sf GENERAL MDC FROM 02H .1050 3 Is the SCM sized to treat the SW from all surfaces at build -out? Yes 4 Is the SCM located away from contaminated soils? Yes 5 What are the side slopes of the SCM (H:V)? 3:1 6 Does the SCM have retaining walls, gabion walls or other engineered side slopes? No 7 Are the inlets, outlets, and receiving stream protected from erosion (10-year storm)? Yes 8 Is there an overflow or bypass for inflow volume in excess of the design volume? Yes 9 What is the method for dewatering the SCM for maintenance? Drawdown Orifice 10 If applicable, will the SCM be cleaned out after construction? Yes 11 Does the maintenance access comply with General MDC (8)? Yes 12 Does the drainage easement comply with General MDC (9)? Yes 13 If the SCM is on a single family lot, does (will?) the plat comply with General MDC (10)? Yes 14 Is there an O&M Agreement that complies with General MDC (11)? Yes 151 Is there an O&M Plan that complies with General MDC (12)? 1 Yes 161 Does the SCM follow the device specific MDC? Yes 17 Was the SCM desi ned bv an NC licensedprofessional? Yes SAND FILTER MDC FROM 02H .1056 18 SHWT elevation (fmsl) N/A 19 Type of sand filter (open or closed) Open 20 If closed, will the filter will be pre -cast or pour -in -place? N/A 21 If closed, top of grate elevation (fmsl) N/A 22 Is this sand filter designed to attenuate peak flows? Yes 23 Volume that can be retained in the sediment chamber (cubic feet) 15214 cf 24 Will there be a permanent pool in the sediment chamber? no 618.00 25 Bottom of the sediment chamber (fmsl) 26 Area of the sediment chamber (square feet 7607 sf 24 in 24 in 27 Physical depth of the sediment chamber (inches) 28 Ponding depth in the sediment chamber, above any permanent pool inches Elevation of top of weir between chambers (fmsl) 29 620 Snnr/ rh—h- 30 Volume that can be retained in the sand chamber (cubic feet) 8990 cf 31 Bottom of the sand chamber (fmsl) 616.50 32 Area of the sand chamber (square feet) 1630 sf 33 Physical de th of the sand chamber inches 18 in 34 Ponding depth in the sand chamber, above the sand surface (inches) 24 in 351 Elevation of the bypass device (fmsl) 623 36 Type of bypass device Spillway 37 Mechanism for distributing flow over the sand surface Riprap 38 Sand specification for sand chamber ASTM C33 39 Depth above underdrain pipe (inches) 6 in 40 Will the media be maintained to drain at least two inches per hour at the sand surface? Yes 41 Is at least one clean -out pipe provided at the low point of each underdrain line? Yes 42 Will clean -out pipes be capped? I Yes Sand Filter 5 3:29 PM 9/27/2022