HomeMy WebLinkAboutWQ0002708_Monitoring - 07-2022_2022081600 \I S 00 0 *4) - Raleigh G Permit # WQOOO27O8 �-� Department of Environment &Natural Resources yQ J Division of Water Resources -Information Processing Unit 1617 Service Center Raleigh, NC 27699 As a part of the permit renewal application, the City of Raleigh submitted monitoring data showing that the naturally occurring background concentrations exceed the groundwater quality standards for arsenic, iron, and manganese. Per 15A NCAC 02L .0202(b)(3), the Permittee had applied to the Director to establish background concentrations and site -specific water quality standards for these parameters. Final determination of background concentration for arsenic, iron, and manganese were pending upon issuance of the final permit. The monitoring data submitted by the City was collected consistent with the Division's requirements as they applied in 2010 and the monitoring data was gathered and analyzed by a consulting firm the Division has recognized as competent to make such determinations at the Neuse River Wastewater Treatment Plant's biosolids application fields. It was requested by the City that until additional site specific data is approved by the Division, the Division would apply the City submitted data as the best available scientific evidence of the naturally occurring groundwater conditions for arsenic, iron and manganese at the Wrenn Road Spray Irrigation Facility. This report submission shows manganese data above the permitted levels and PH data below the permitted range for the groundwater standards listed in attachment "C" of the permit. The historical manganese and PH data provided in a 1990 consultant report as part of a land treatment site evaluation and the 2010 consultant report submitted during the most recent permit renewal process shows background data consistent with current manganese and PH levels and should be considered as naturally occurring background water quality. In attachment C, footnote 8 of the final permit, it states that the Division shall use enforcement discretion for any apparent groundwater standard violation for arsenic, iron or manganese until background concentrationg-and C: site -specific groundwater quality standards can be determined. rn � N 8 ll z Z ti ;nature of P . ee (or authorized agent) Date Raleigh Water: Serving the people of Garner, Knightdale, Raleigh, Rolesville, Wake Forest, Wendell, and Zebulon areas. One Exchange Plaza Building 1 1 Exchange Plaza I Suite 600 1 Raleigh, North Carolina 27601 City of Raleigh (mailing address) I Post Office Box 590 1 Raleigh, North Carolina 27602-0590 GW-59A COMPLIANCE REPORT FORM Permit# WQ0002708 (Sulonif one each monitoring period Wilt GiV-57 Jitrtns.) 1 Enter date monitoring results were due. t.$13112022_ ) Will this monitoring report (GW-59 and GW-59A) YEIS NO be submitted after the established due date? Was any required information missing on the CNV-59 report forms? 2 YES NO IF the answer to question 1 or 2 is "YES", list in the space provided below the well identification number(s) and explain the problems encountered in obtaining the required information Are any of the monitor wells in need of repair or maintenance (damaged casing, unlocked or missing cap, missing 3 YES NO identification plate, area overgrown, etc.)? l/ the answer is "Yes", confact the Regional Office Jbr quid mce. 4 Are any monitored constituents equal to or above the established standards? YES NO If the answer to question 4 is "NO", skip to section 8. If the answer to question 4 is "YES"list the affected wells individually with constituent(s) and concentration(s) exceeding standards in the space provided below: MW9 pH6.46 For the constituents identified in question 4 above, have standards been exceeded previously for the 5 YES NO same constituent(s) in the same well(s) in the last two years? If the answer to question 5 is "NO", skip to section 8. If the answer to question 5 is "YES", list in the space provided below, each well with constituent(s) exceeding standards, concentration(s) reported, and sample collection date for each occurrence (for the last two years). The pH's for MW3, MW8, and MW9 are in the standard range for the City of Raleigh Iron and Manganese are new groundwater characteristic listed in the new permit See the attached document regarding the constituents Are the monitoring wells listed In section 5 located at or beyond the review boundary? If the answer Is "YES", a groundwater quality problem may be occurring. CONTACT THE REGIONAL 6 YES NO OFFICE IMMEDIATELY FOR GUIDANCE. If the answer is "NO", monitoring wells may be improperly located; contact the Regional Office. 7 Is the permittee implementing previously approved actions required by the Division Involving this YES NO groundwater quality problem? If the answer to question 7 is "YES", describe those actions in the space provided below. If the answer to question 7 is "NO", contact the Regional Office within 90 days; an evaluation may be reguired to determine the impact the waste disposal system is having at the review and comi2liance boundaries surrounding this facility, Failure to do so may subject the permittee to a Notice of Violation fines, and/or penalties. 8 The person completing this portion (GW-59A) of the monitoring report should sign below and submit this form with GW-59 forms for required wells to the address provided at the top of the current GW-59 form. I hereby acknowledge that the ove information was evaluated and the information submitted in this (Compliance Repoi 9A) is true to the best knowledge. report and complete of my Signatu ermlttee (or Authorized Agent) Date CNN-59a 12/8i2003 SUBMIT FORM ON YELLOW PAPER ONLY . . .• DEPARTMENT OF ENVIRONMENT & NATURAL RESOURCES GROUNDWATER QUALITY MONITORING: DIVISION OF WATER RESOURCES - INFORMATION PROCESSING UNIT COMPLIANCE REPORT FORM •. 1617 MAIL SERVICE CENTER, RALEIGH, NC 27699-1617 Phone: 919-807-6306 FACILITY INFORMATION Please Print Clearly or Type PERMIT Number: Expiration Date: September 30, 2026 Facility Name: City of Raleigh, Wrenn Road Spray Irrigation Facility Non -Discharge WQ 0002708 UIC Permit Name (if different): NPDES Other Facility Address: 8828 Wrenn Road TYPE OF PERMITTED OPERATION BEING MONITORED ❑ Lagoon ❑ Remediation: Infiltration Gallery Garner NC 27529 County Wake (city) (state) Iz'p) N Spray Field ❑ Remediation: Contact Person: Chris Phelps Telephone#: 919-996-3172 ❑ Rotary Distributor ❑ Land Application of Sludge Well Location/Site Name: Wrenn Road No. of wells to be sampled: 3 ❑ Water Source Heat Pump ❑ Other: (from Permit SAMPLING INFORMATION If WELL WELL ID NUMBER (from Permit): B3 Date sample collected: 7/7/2022 FIELD ANALYSES: WAS Well Depth: 29.54 ft. Well Diameter: 2 in. pH 00400 6.68 units Temp. 000lo 18.1 °C DRY at Depth to Water Level 82546: 22.5 ft. below measuring point Screened Interval: 15 ft. to 30 ft. SpecCond. 00094 53.8 ttMhos — . . time of sampling, Measuring Point is 3 ft. above land surface Relative M.P. Elevation: ft. Odor 00085 No check Volume of water pumped/bailed before sampling: 3.67 gallons Appearance Clear here:❑ Samples for metals were collected unfiltered: E YES ❑ NO and field acidified: N YES ❑ NO LABORATORY INFORMATION Date sample analyzed: 7/7/2022 Laboratory Name: City of Raleigh, EM Johnson Water Laboratory Certification No. 426 PARAMETERS NOTE: Values should reflect dissolved and colloidal concentrations. COD 00335 mg/L Nitrite (NO2) as N 00615 mg/L Pb - Lead 01051 ug/L Coliform: MF Fecal 31616 0 /100mL Nitrate (NO3) as N 00620 mg/L Zn - Zinc 01092 mg/L Coliform: MF Total 31504 /100mL Phosphorus: Total as P 00665 mg/L (Note Use MPN method for highly turbid samples) Orthophosphate 70507 mg/L Other (Specify Compounds and ConcepVgon Units): Dissolved Solids: Total 70300 mg/L Al -Aluminum 01105 mg/L {jJ pH (Lab) 00403 6.68 units Ba - Barium 01007 ug/L TOC 00680 <1 mg/L Ca - Calcium 00916 mg/L Chloride oo94o mg/L Cd - Cadmium 01027 ug/L Arsenic 01002 <10 ug/L Chromium: Total 01034 ug/L Grease and Oils 00552 mg/L Cu - Copper 01042 mg/L ORGANICS: (by GC. GC/MS, HPLC) Phenol 32730 ug/L Fe - Iron 01045 <60 ug/L (Specify test and method #. ATTACH LAB REPORT.) Sulfate 00945 mg/L Hg - Mercury 71900 ug/L Lab Report Attached? ❑ Yes (1) ❑ No (0) Specific Conductance 00095 µMhos K - Potassium 00937 mg/L VOC 7873 method # Total Ammonia 00610 mg/L Mg - Magnesium 00927 mg/L method # (Ammonia Nitrogen, NH3asN. Ammonia Nitrogen, Total) Mn - Manganese 01055 <50 ug/L , method # TKN as N 00625 mg/L Ni - Nickel 01067 ug/L method # For Remediation Systems Only (Attach Lab Reports): Influent Total VOCs: Chris Phelps, Acting Assistant Director Permittee (or Authorized Aqent) Name and Title - Please print or type Effluentof O a, and that the laboratory analytirsl data was sibility of finer and imprisciiment for knowinc - - mg/L VOC Removal% // Z Z GW-59 Rev.8/2013 • • DEPARTMENT OF ENVIRONMENT & NATURAL RESOURCES GROUNDWATER QUALITY MONITORING: • • • • DIVISION OF WATER RESOURCES - INFORMATION PROCESSING UNIT COMPLIANCE REPORT FORM 1617 MAIL SERVICE CENTER, RALEIGH, NC 27699-1617 Phone: 919-807-6306 FACILITY INFORMATION Please Print Clearly or Type PERMIT Number: Expiration Date September 30, 2026 Facility Name: City of Raleigh, Wrenn Road Spray Irrigation Facility Non -Discharge WQ 0002708 UIC NPDES Other Permit Name (if different): Facility Address: 8828 Wrenn Road TYPE OF PERMITTED OPERATION BEING MONITORED ❑ Lagoon ❑ Remediation: Infiltration Gallery Garner NC 27529 County Wake (city) (state) ;Zlp) 0 Spray Field ❑ Remediation: Contact Person: Chris Phelps Telephone#: 919-996-3172 ❑ Rotary Distributor ❑ Land Application of Sludge Well Location/Site Name: Wrenn Road No. of wells to be sampled: 3 ❑ Water Source Heat Pump ❑ Other: (from Permit) SAMPLING INFORMATION If WELL WELL ID NUMBER (from Permit): B3 Date sample collected: 7/7/2022 FIELD ANALYSES: WAS Well Depth: 29.54 ft. Well Diameter: 2 in. pH 0400 6.68 units Temp. 000to 18.1 °C DRY at Depth to Water Level 82546: 22.5 ft below measuring point Screened Interval: 15 ft. to 30 ft. Spec. Cond. 00094 53.8 µMhos time of sampling, Measuring Point is 3 ft. above land surface Relative M.P. Elevation: ft. Odor 00085 No check Volume of water pumped/bailed before sampling 3.67 gallons Appearance Clear here:❑ Samples for metals were collected unfiltered: 0 YES ❑ NO and field acidified: ■ YES ❑ NO LABORATORY INFORMATION Date sample analyzed: 7/7/2022 Laboratory Name: Environment 1 Certification No. 10 PARAMETERS NOTE: Values should reflect dissolved and colloidal concentrations. COD 00335 mg/L Nitrite (NO2) as N 00615 mg/L Pb - Lead o1o5i ug/L Coliform: MF Fecal 31616 /100mL Nitrate (NO3) as N 00620 <0.04 mg/L Zn - Zinc 01092 mg/L Coliform: MF Total 31504 /100mL Phosphorus Total as P 00665 <0.04 mg/L (Note: Use MPN method for highly turbid samples) Orthophosphate 70507 mg/L Other (Specify Compounds and Concentration Units): Dissolved Solids:Total 70300 33 mg/L Al - Aluminum 01105 mg/L pH (Lab) 00403 units Ba - Barium 01007 ug/L TOC 00680 mg/L Ca - Calcium 00916 mg/L Chloride 00940 5 mg/L Cd - Cadmium 01027 ug/L Arsenic 01002 ug/L Chromium: Total 01034 ug/L Grease and Oils 00552 mg/L Cu - Copper 01042 mg/L ORGANICS: (by GC, GC/MS, HPLC) Phenol 32730 ug/L Fe - Iron 01045 ug/L (Specify test and method #. ATTACH LAB REPORT.) Sulfate 00945 <5.0 mg/L Hg - Mercury 71900 ug/L Lab Report Attached? ❑ Yes (1) ❑ No (0) Specific Conductance 00095 µMhos K - Potassium 00937 mg/L VOC 7873 method # Total Ammonia 00610 mg/L Mg - Magnesium 00927 mg/L method # (Ammonia Nitrogen. NH3as N, Ammonia Nitrogen, Total) Mn - Manganese 01055 ug/L , method # TKN as N 00625 mg/L Ni - Nickel 01067 ug/L method # For Remediation Systems Only (Attach Lab Reports): Influent Total VOCs: mg/L Effluent Total VOCs: mg/L VOC Removal% Chris Phelps, Acting Assistant Director Permittee (or Authorized Aqent) Name and Title - Please print or type SUBMIT FORM ON YELLOW PAPER ONLY DEPARTMENT OF ENVIRONMENT & NATURAL RESOURCES GROUNDWATER QUALITY MONITORING: DIVISION OF WATER RESOURCES -INFORMATION PROCESSING UNIT COMPLIANCE REPORT FORM 1617 MAIL SERVICE CENTER, RALEIGH, NC 27699-1617 Phone: 919-807-6306 FACILITY INFORMATION Please Print Clearly or Type PERMIT Number: Expiration Date: September 30, 2026 Facility Name: City of Raleigh, Wrenn Road Spray Irrigation Facility Non -Discharge WQ 0002708 UIC Permit Name (if different): NPDES Other Facility Address: 8828 Wrenn Road TYPE OF PERMITTED OPERATION BEING MONITORED Garner NC 27529 County Wake ❑ Lagoon ❑ Remediation: Infiltration Gallery (City) (state) (zip) ■ Spray Field ❑ Remediation: Contact Person: Chris Phelps Telephone#: 919-996-3172 ❑ Rotary Distributor ❑ Land Application of Sludge Well Location/Site Name: Wrenn Road No. of wells to be sampled: 3 ❑ Water Source Heat Pump ❑ Other: from Permit SAMPLING INFORMATION If WELL WELL ID NUMBER (from Permit): B3 Date sample collected: 7/7/2022 FIELD ANALYSES: WAS Well Depth: 29.54 ft. Well Diameter: 2 in. pH o040o: 6.68 units Temp. 000lo 18.1 °C DRY at Depth to Water Level 82546: 22.6 ft. below measuring point Screened Interval: 15 ft. to 30 ft. Spec. Cond. 000m: 53.8 µMhos time of sampling, Measuring Point is 3 ft. above land surface Relative M.P. Elevation: ft. Odor 000m: No check Volume of water pumped/bailed before sampling: 3.67 gallons Appearance Clear here:❑ Samples for metals were collected unfiltered: ■ YES ❑ NO and field acidified: ■ YES ❑ NO LABORATORY INFORMATION Date sample analyzed: 7/11/2022 Laboratory Name: Eurofins Lab Certification No. 18700 PARAMETERS NOTE: Values should reflect dissolved and colloidal concentrations. COD 00335 mg/L Nitrite (NO2) as N 00615 mg/L Pb - Lead 01051 ug/L Coliform: MF Fecal 31616 /100mL Nitrate (NO3) as N 00620 mg/L Zn - Zinc 01092 mg/L Coliform: MF Total 31504 /100mL Phosphorus: Total as P 00665 mg/L (Note: Use MPN method for highly turbid samples) Orthophosphate 70507 mg/L Other (Specify Compounds and Concentration Units): Dissolved Solids:Total 70300 mg/L Al - Aluminum 01105 mg/L Acrylamide - no detection pH (Lab) 00403 units Ba - Barium 01007 ug/L TOC 00680 mg/L Ca - Calcium 00916 mg/L Chloride oo94o mg/L Cd - Cadmium 01027 ug/L Arsenic 01002 ug/L Chromium: Total 01034 ug/L Grease and Oils 00552 mg/L Cu - Copper 01042 mg/L ORGANICS: (by GC, GC/MS, HPLC) Phenol 32730 ug/L Fe - Iron o1o45 ug/L (Specify test and method #. ATTACH LAB REPORT.) Sulfate 00945 mg/L Hg - Mercury 71900 ug/L Lab Report Attached? ❑ Yes (1) ❑ No (0) Specific Conductance 00095 µMhos K - Potassium 00937 mg/L VOC 7873 method # Total Ammonia 00610 mg/L Mg - Magnesium 00927 mg/L method # (Ammonia Nitrogen, NH3 as N, Ammonia Nitrogen, Total) Mn - Manganese 01055 ug/L method # TKN as N 00625 mg/L Ni - Nickel 01067 ug/L method # For Remediation Systems Only (Attach Lab Reports): Influent Total VOCs: mg/L Effluent Total VOCs: mg/L VOC Removal% v Chris Phelps, Acting Assistant Director `l Z Permittee (or Authorized Aqent) Name and Title - Please print or tvpe S nature of Permi or Authorized Aqent) ate) GW-59 Rev.8/2013 DEPARTMENT OF ENVIRONMENT & NATURAL RESOURCES GROUNDWATER QUALITY MONITORING: DIVISION OF WATER RESOURCES -INFORMATION PROCESSING UNIT COMPLIANCE REPORT FORM 1617 MAIL SERVICE CENTER, RALEIGH, NC 27699-1617 Phone: 919-807-6306 FACILITY INFORMATION Please Print Clearly or Type PERMIT Number: Expiration Date: September 30, 2026 Facility Name: City of Raleigh, Wrenn Road Spray Irrigation Facility Non -Discharge WQ 0002708 UIC Permit Name (if different): NPDES Other Facility Address: 8828 Wrenn Road TYPE OF PERMITTED OPERATION BEING MONITORED Garner NC 27529 County Wake ❑ Lagoon ❑ Remediation: Infiltration Gallery (City) (state) (zip) E Spray Field ❑ Remediation: Contact Person: Chris Phelps Telephone#: 919-996-3172 ❑ Rotary Distributor ❑ Land Application of Sludge Well Location/Site Name: Wrenn Road No. of wells to be sampled: 3 ❑ Water Source Heat Pump ❑ Other: from Permit SAMPLING INFORMATION If WELL WELL ID NUMBER (from Permit): B8 Date sample collected: 7/7/2022 FIELD ANALYSES: WAS Well Depth: 29.54 ft. Well Diameter: 2 in. pH oo400: 6.93 units Temp. 000io 17.4 °C DRY at Depth to Water Level 82546: 22.7 ft. below measuring point Screened Interval: 15 ft. to 30 ft. Spec. Cond. 00094: 90.5 µMhos time of sampling, Measuring Point is 3 ft. above land surface Relative M.P. Elevation: ft. Odor 00085: No check Volume of water pumped/bailed before sampling: 3.55 gallons Appearance Clear here.,[:] Samples for metals were collected unfiltered: ■ YES ❑ NO and field acidified: ■ YES ❑ NO LABORATORY INFORMATION Date sample analyzed: 7/7/2022 Laboratory Name: City of Raleigh, EM Johnson Water Laboratory Certification No. 426 PARAMETERS NOTE: Values should reflect dissolved and colloidal concentrations. COD 00335 mg/L Nitrite (NO2) as N 00615 mg/L Pb - Lead 01051 ug/L Coliform: MF Fecal 31616 0 /100mL Nitrate (NO3) as N 00620 mg/L Zn - Zinc 01092 mg/L Coliform: MF Total 31504 /100mL Phosphorus: Total as P 00665 mg/L (Note. Use MPN method for highly turbid samples) Orthophosphate 70507 mg/L Other (Specify Compounds and Concentration Units): Dissolved Solids:Total 70300 mg/L Al - Aluminum 01105 mg/L pH (Lab) 00403 6.93 units Ba - Barium 01007 ug/L TOC om8o <1 mg/L Ca - Calcium 00916 mg/L Chloride oo94o mg/L Cd - Cadmium 01027 ug/L Arsenic 01002 <10 ug/L Chromium: Total olo34 ug/L Grease and Oils 00552 mg/L Cu - Copper 01042 mg/L ORGANICS: (by GC, GC/MS, HPLC) Phenol 32730 ug/L Fe - Iron 01045 <60 ug/L (Specify test and method #. ATTACH LAB REPORT.) Sulfate 00945 mg/L Hg - Mercury 71900 ug/L Lab Report Attached? ❑ Yes (1) ❑ No (0) Specific Conductance 00095 µMhos K - Potassium 00937 mg/L VOC 7873 method # Total Ammonia 00610 mg/L Mg - Magnesium 00927 mg/L method # (Ammonia Nitrogen, NH3as N, Ammonia Nitrogen, Total) Mn - Manganese of 055 <50 ug/L , method # TKN as N 00625 mg/L Ni - Nickel 01067 ug/L method # For Remediation Systems Only (Attach Lab Reports): Influent Total VOCs: mg/L Effluent Total VOCs: mg/L VOC Removal% Chris Phelps, Acting Assistant Director Permittee (or Authorized Aqent) Name and Title - Please print or type GROUNDWATER QUALITY MONITORING: COMPLIANCE REPORT FORM Please Print Clearly or Type Facility Name: City of Raleigh, Wrenn Road Spray Irrigation Facili Permit Name (if different): Facility Address: 8828 Wrenn Road Garner NC 27529 County Wake (City) (State) (zip) act Person: Chris Phelps Telephone#: 919-996-3172 Location/Site Name: Wrenn Road No. of wells to be sampled: 3 Ifrnm P WELL ID NUMBER (from Permit): B8 Date sample collected: Well Depth: 29.54 ft. Well Diameter: Depth to Water Level 82546: 22.7 ft. below measuring point Screened Interval: Measuring Point is 3 ft. above land surface Relative M.P. Elevation: 7nn022 DEPARTMENT OF ENVIRONMENT & NATURAL RESOURCES DIVISION OF WATER RESOURCES - INFORMATION PROCESSING UNIT 1617 MAIL SERVICE CENTER, RALEIGH, NC 27699-1617 Phone: 919-807-6306 PERMIT Number: Expiration Date: September 30, 2026 Non -Discharge WQ 0002708 UIC NPDES Other TYPE OF PERMITTED OPERATION BEING MONITORED ❑ Lagoon ❑ Remediation: Infiltration Gallery ■ Spray Field ❑ Remediation: ❑ Rotary Distributor ❑ Land Application of Sludge ❑ Water Source Heat Pump ❑ Other: 2 in. 15 ft. to 30 ft. ft. Volume of water pumped/bailed before sampling: 3.55 gallons Samples for metals were collected unfiltered: ■ YES ❑ NO and field acidified: ■ YES ❑ NO FIELD ANALYSES: pH oo400: 6.93 units Spec. Cond. 00094: Odor 000m: No Appearance Clear Temp. 000lo 17.4 °C on _;; uMhos Date sample analyzed: 7/7/2022 Laboratory Name: Environment 1 Certification No. 10 PARAMETERS NOTE: Values should reflect dissolved and colloidal concentrations. COD 00335 mg/L Nitrite (NO2) as N 00615 mg/L Pb - Lead 01051 ug/L Coliform: MF Fecal 31616 /100mL Nitrate (NO3) as N 00620 <0.04 mg/L Zn - Zinc 01092 mg/L Coliform: MF Total 31504 /100mL Phosphorus: Total as P 00665 <0.04 mg/L (Note: Use MPN method for highly turbid samples) Orthophosphate 70507 mg/L Other (Specify Compounds and Concentration Units): Dissolved Solids:Total 70300 59 mg/L Al - Aluminum 01105 mg/L pH (Lab) 00403 units Ba - Barium 01007 ug/L TOC 00680 mg/L Ca - Calcium oo916 mg/L Chloride oo94o 20 mg/L Cd - Cadmium 01027 ug/L Arsenic 01002 ug/L Chromium: Total 01034 ug/L Grease and Oils 00552 mg/L Cu - Copper 01042 mg/L ORGANICS: (by GC, GC/MS, HPLC) Phenol 32730 ug/L Fe - Iron 01045 ug/L (Specify test and method #. ATTACH LAB REPORT.) Sulfate 00945 <5.0 mg/L Hg - Mercury 71900 ug/L Lab Report Attached? ❑ Yes (1) ❑ No (0) Specific Conductance 00095 µMhos K - Potassium 00937 mg/L VOC 7873 method # Total Ammonia 00610 mg/L Mg - Magnesium 00927 mg/L method # (Ammonia Nitrogen, N1,13as N, Ammonia Nitrogen, Total) Mn - Manganese 01055 ug/L , method # TKN as N 00625 mg/L Ni - Nickel 01067 ug/L method # For Remediation Systems Only (Attach Lab Reports): Influent Total VOCs: mg/L Effluent Total VOCs: mg/L VOC Removal% Chris Phelps, Acting Assistant Director Permittee (or Authorized Aqent) Name and Title - Please print or type If WELL DRY at time of sampling, check here: ❑ • •DEPARTMENT OF ENVIRONMENT & NATURAL RESOURCES GROUNDWATER QUALITY MONITORING: DIVISION OF WATER RESOURCES - INFORMATION PROCESSING UNIT COMPLIANCE REPORT FORM 1617 MAIL SERVICE CENTER, RALEIGH, NC 27699-1617 Phone: 919-807-6306 FACILITY INFORMATION Please Print Clearly or Type PERMIT Number: Expiration Date: September 30, 2026 Facility Name: City of Raleigh, Wrenn Road Spray Irrigation Facility Non -Discharge WQ 0002708 UIC Permit Name (if different): NPDES Other Facility Address: 8828 Wrenn Road TYPE OF PERMITTED OPERATION BEING MONITORED Garner NC 27529 County Wake ❑ Lagoon ❑ Remediation: Infiltration Gallery (ciy) (State) (zip) ■ Spray Field ❑ Remediation: Contact Person: Chris Phelps Telephone#: 919-996-3172 ❑ Rotary Distributor ❑ Land Application of Sludge Well Location/Site Name: Wrenn Road No. of wells to be sampled: 3 ❑ Water Source Heat Pump ❑ Other: from Permit SAMPLING INFORMATION If WELL WELL ID NUMBER (from Permit): B8 Date sample collected: 7/7/2022 FIELD ANALYSES: WAS Well Depth: 29.54 ft. Well Diameter: 2 in. pH 00000: 6.93 units Temp. 000lo 17.4 °C DRY at Depth to Water Level 82546: 22.7 ft. below measuring point Screened Interval: 15 ft. to 30 ft. Spec. Cond. 00094: 90.5 µMhos time of sampling, Measuring Point is 3 ft. above land surface Relative M.P. Elevation: ft. Odor 00085: No check Volume of water pumped/bailed before sampling: 3.55 gallons Appearance Clear here: ❑ Samples for metals were collected unfiltered: ■ YES El NO and field acidified: ■ YES ❑ NO LABORATORY INFORMATION Date sample analyzed: 711112022 Laboratory Name: Eurofins Certification No. 18700 PARAMETERS NOTE: Values should reflect dissolved and colloidal concentrations. COD 00335 mg/L Nitrite (NO2) as N 00615 mg/L Pb - Lead o1o51 ug/L Coliform: MF Fecal 31616 /100mL Nitrate (NO3) as N 00620 mg/L Zn - Zinc 01092 mg/L Coliform: MF Total 31504 /100mL Phosphorus: Total as P 00665 mg/L (Note: Use MPN method for highly turbid samples) Orthophosphate 70507 mg/L Other (Specify Compounds and Concentration Units): Dissolved Solids:Total 70300 mg/L Al -Aluminum 01105 mg/L Acrylamide - no detection pH (Lab) 00403 units Ba - Barium 01007 ug/L TOC oo68o mg/L Ca - Calcium 00916 mg/L Chloride 00940 mg/L Cd - Cadmium 01027 ug/L Arsenic 01002 ug/L Chromium: Total olo34 ug/L Grease and Oils 00552 mg/L Cu - Copper 01042 mg/L ORGANICS: (by GC, GC/MS, HPLC) Phenol 32730 ug/L Fe - Iron 01045 ug/L (Specify test and method #. ATTACH LAB REPORT.) Sulfate 00945 mg/L Hg - Mercury 71900 ug/L Lab Report Attached? ❑ Yes (1) ❑ No (0) Specific Conductance 00095 µMhos K - Potassium 00937 mg/L VOC 7873 method # Total Ammonia 00610 mg/L Mg - Magnesium 00927 mg/L method # (Ammonia Nitrogen; N1­13as N, Ammonia Nitrogen, Total) Mn - Manganese 01055 ug/L , method # TKN as N 00625 mg/L Ni - Nickel 01067 ug/L method # For Remediation Systems Only (Attach Lab Reports): Influent Total VOCs: mg/L Effluent Total VOCs: mg/L VOC Removal% • . DEPARTMENT OF ENVIRONMENT & NATURAL RESOURCES GROUNDWATER QUALITY MONITORING: DIVISION OF WATER RESOURCES -INFORMATION PROCESSING UNIT COMPLIANCE REPORT FORM 1617 MAIL SERVICE CENTER, RALEIGH, NC 27699-1617 Phone: 919-807-6306 FACILITY INFORMATION Please Print Clearly or Type PERMIT Number: Expiration Date. September 30, 2026 Facility Name: City of Raleigh, Wrenn Road Spray Irrigation Facility Non -Discharge WQ 0002708 UIC Permit Name (if different): NPDES Other Facility Address: 8828 Wrenn Road TYPE OF PERMITTED OPERATION BEING MONITORED ❑ Lagoon ❑ Remediation: Infiltration Gallery Garner NC 27529 County Wake (city) (state) (zip) ■ Spray Field El Remediation: Contact Person: Chris Phelps Telephone# 919-996-3172 ❑ Rotary Distributor ❑ Land Application of Sludge Well Location/Site Name. Wrenn Road No. of wells to be sampled: 3 ❑ Water Source Heat Pump ❑ Other: from Permit SAMPLING INFORMATION If WELL WELL ID NUMBER (from Permit): B9 Date sample collected: 7/7/2022 FIELD ANALYSES: WAS Well Depth 29.54 ft. Well Diameter: 2 in. pH 00400 6.46 units Temp. 000io 17.8 DRY at Depth to Water Level 82546: 13.0 ft. below measuring point Screened Interval: 15 ft. to 30 ft. Spec. Cond. 00094 203.9 µMhos time of sampling. Measuring Point is 3 ft. above land surface Relative M.P. Elevation: ft. Odor 00085 No check Volume of water pumped/bailed before sampling: 8.33 gallons Appearance Clear here: ❑ Samples for metals were collected unfiltered ■ YES ❑ NO and field acidified ■ YES ❑ NO LABORATORY INFORMATION Date sample analyzed: 7/7/2022 Laboratory Name: City of Raleigh, EM Johnson Water Laboratory Certification No. 426 PARAMETERS NOTE: Values should reflect dissolved and colloidal concentrations. COD 00335 mg/L Nitrite (NO2) as N 00615 mg/L Pb - Lead 01051 ug/L Coliform MF Fecal 31616 0 /100mL Nitrate (NO3) as N 00620 mg/L Zn - Zinc 01092 mg/L Coliform: MF Total 3i504 /100mL Phosphorus: Total as P 00665 mg/L (Note. Use MPN method for highly turbid samples) Orthophosphate 70507 mg/L Other (Specify Compounds and Concentration Units): Dissolved Solids:Total 70300 mg/L Al - Aluminum 01105 mg/L pH (Lab) 00403 6.46 units Ba - Barium 01007 ug/L TOC 00680 <1 mg/L Ca - Calcium 00916 mg/L Chloride 00940 mg/L Cd - Cadmium 01027 ug/L Arsenic 01002 <10 ug/L Chromium: Total 01034 ug/L Grease and Oils 00552 mg/L Cu - Copper 01042 mg/L ORGANICS: (by GC, GC/MS, HPLC) Phenol 32730 ug/L Fe - Iron 01045 70 ug/L (Specify test and method #. ATTACH LAB REPORT.) Sulfate 00945 mg/L Hg - Mercury 71900 ug/L Lab Report Attached? ❑ Yes (1) ❑ No (0) Specific Conductance 00095 µMhos K - Potassium 00937 mg/L VOC 7873 method # Total Ammonia 00610 mg/L Mg - Magnesium 00927 mg/L method # (Ammonia Nitrogen, NH3 as N, Ammonia Nitrogen, Total) Mn - Manganese o1o55 <50 ug/L , method # TKN as N 00625 mg/L Ni - Nickel 01067 ug/L method # For Remediation Systems Only (Attach Lab Reports): Influent Total VOCs: mg/L Effluent Total VOCs: mg/L VOC Removal% • • DEPARTMENT OF ENVIRONMENT & NATURAL RESOURCES GROUNDWATER QUALITY MONITORING: • • • • DIVt31ON OF WATER RESOURCES - INFORMATION PROCESSING UNIT COMPLIANCE REPORT FORM 1617 MAIL SERVICE CENTER, RALEIGH, NC 27699-1617 Phone: 919-807-6306 FACILITY INFORMATION Please Print Clearly or Type PERMIT Number: Expiration Date: September 30, 2026 Facility Name: City of Raleigh, Wrenn Road Spray Irrigation Facility Non -Discharge WQ 0002708 UIC NPDES Other Permit Name (if different): Facility Address: 8828 Wrenn Road TYPE OF PERMITTED OPERATION BEING MONITORED Garner NC 27529 County Wake ❑ Lagoon ❑ Remediation: Infiltration Gallery (city) (state] (zip; ■ Spray Field ❑ Remediation: Contact Person: Chris Phelps Telephone#: 919-996-3172 ❑ Rotary Distributor ❑ Land Application of Sludge Well Location/Site Name: Wrenn Road No. of wells to be sampled: 3 ❑ Water Source Heat Pump ❑ Other: from Permit SAMPLING INFORMATION If WELL WELL ID NUMBER (from Permit): B9 Date sample collected: 7/7/2022 FIELD ANALYSES: WAS Well Depth: 29.54 ft. Well Diameter: 2 in pH 00400 6.46 units Temp. 000io 17.8 DRY at Depth to Water Level 82546: 13.0 ft. below measuring point Screened Interval: 15 ft. to 30 ft. Spec. Cond. 00094 203.9 µMhos time of sampling. Measuring Point is 3 ft above land surface Relative M.P. Elevation: ft. Odor 00085 No check Volume of water pumped/bailed before sampling: 8.33 gallons Appearance Clear here:❑ Samples for metals were collected unfiltered: ■ YES ❑ NO and field acidified: ■ YES ❑ NO LABORATORY INFORMATION Date sample analyzed: 7/7/2022 Laboratory Name: Environment 1 Certification No. 10 PARAMETERS NOTE: Values should reflect dissolved and colloidal concentrations. COD 00335 mg/L Nitrite (NO2) as N 00615 mg/L Pb - Lead 01051 ug/L Coliform: MF Fecal 31616 /100mL Nitrate (NO3) as N 00620 <0.04 mg/L Zn - Zinc 01092 mg/L Coliform: MF Total 31504 /100mL Phosphorus: Total as P 00665 <0.04 mg/L (Note: Use MPN method for highly turbid samples) Orthophosphate 70507 mg/L Other (Specify Compounds and Concentration Units): Dissolved Solids:Total 70300 110 mg/L Al - Aluminum 01 105 mg/L pH (Lab) 00403 units Ba - Barium 01007 ug/L TOC 00680 mg/L Ca - Calcium 00916 mg/L Chloride 00940 34 mg/L Cd - Cadmium 01027 ug/L Arsenic 01002 ug/L Chromium: Total 01034 ug/L Grease and Oils 00552 mg/L Cu - Copper 01042 mg/L ORGANICS: (by GC, GC/MS, HPLC) Phenol 32730 ug/L Fe - Iron 01045 ug/L (Specify test and method #. ATTACH LAB REPORT.) Sulfate 00945 6 mg/L Hg - Mercury 71900 ug/L Lab Report Attached? ❑ Yes (1) ❑ No (0) Specific Conductance 00095 µMhos K - Potassium 00937 mg/L VOC 7873 method # Total Ammonia oo6lo mg/L Mg - Magnesium 00927 mg/L method # (Ammonia Nitrogen: NH3as N. Ammonia Nitrogen. Total) Mn - Manganese 01055 ug/L method # TKN as N 00625 mg/L Ni - Nickel 01067 ug/L method # For Remediation Systems Only (Attach Lab Reports): Influent Total VOCs: mg/L Effluent Total VOCs: mg/L VOC Removal% • • DEPARTMENT OF ENVIRONMENT & NATURAL RESOURCES GROUNDWATER QUALITY MONITORING: • • • • DIVISION OF WATER RESOURCES - INFORMATION PROCESSING UNIT COMPLIANCE REPORT FORM 1617 MAIL SERVICE CENTER, RALEIGH, NC 27699-1617 Phone: 919-807-6306 FACILITY INFORMATION Please Print Clearly or Type PERMIT Number: Expiration Date: September 30, 2026 Facility Name: City of Raleigh, Wrenn Road Spray Irrigation Facility Non -Discharge WQ 0002708 UIC Permit Name (if different): NPDES Other Facility Address: 8828 Wrenn Road TYPE OF PERMITTED OPERATION BEING MONITORED Garner NC 27529 County Wake ❑ Lagoon ❑ Remediation: Infiltration Gallery (city) (State) (zip) ■ Spray Field ❑ Remediation: Contact Person: Chris Phelps Telephone#: 919-996-3172 ❑ Rotary Distributor ❑ Land Application of Sludge Well Location/Site Name: Wrenn Road No. of wells to be sampled: 3 ❑ Water Source Heat Pump ❑ Other: from Permit SAMPLING INFORMATION If WELL WELL ID NUMBER (from Permit): B9 Date sample collected: 7/7/2022 FIELD ANALYSES: WAS Well Depth: 29.54 ft. Well Diameter: 2 in. pH o0400: 6.46 units Temp. 000lo 17.8 DRY at Depth to Water Level 82546: 13.0 ft. below measuring point Screened Interval: 15 ft. to 30 ft. Spec. Cond. 00094: 203.9 µMhos time of sampling, Measuring Point is 3 ft. above land surface Relative M.P. Elevation: ft. Odor 00085: No check Volume of water pumped/bailed before sampling: 8.33 gallons Appearance Clear here:❑ Samples for metals were collected unfiltered: ■ YES ❑ NO and field acidified: ■ YES ❑ NO LABORATORY INFORMATION Date sample analyzed: 7/11/2022 Laboratory Name: Eurofins Certification No. 18700 PARAMETERS NOTE: Values should reflect dissolved and colloidal concentrations. COD 00335 mg/L Nitrite (NO2) as N 00615 mg/L Pb - Lead 01051 ug/L Coliform: MF Fecal 31616 /1 OOmL Nitrate (NO3) as N 00620 mg/L Zn - Zinc 01092 mg/L Coliform: MF Total 31504 /100mL Phosphorus: Total as P 00665 mg/L (Note: Use MPN method for highly turbid samples) Orthophosphate 70507 mg/L Other (Specify Compounds and Concentration Units): Dissolved Solids:Total 70300 mg/L Al - Aluminum 01105 mg/L Acrylamide - no detection pH (Lab) 00403 units Ba - Barium 01007 TOC 00680 mg/L Ca - Calcium o0916 mg/L Chloride 00940 mg/L Cd - Cadmium 01027 ug/L Arsenic 01002 ug/L Chromium: Total 01034 ug/L Grease and Oils 00552 mg/L Cu - Copper 01042 mg/L ORGANICS: (by GC, GC/MS, HPLC) Phenol 32730 ug/L Fe - Iron 01045 ug/L (Specify test and method #. ATTACH LAB REPORT.) Sulfate 00945 mg/L Hg - Mercury 71900 ug/L Lab Report Attached? ❑ Yes (1) ❑ No (0) Specific Conductance 00095 µMhos K - Potassium 00937 mg/L VOC 7873 method # Total Ammonia 00610 mg/L Mg - Magnesium 00927 mg/L method # (Ammonia Nitrogen, NH3as N, Ammonia Nitrogen, Total) Mn -Manganese oloss ug/L ,method # TKN as N 00625 mg/L Ni - Nickel 01067 ug/L method # For Remediation Systems Only (Attach Lab Reports): Influent Total VOC& mg/L Effluent Total VOCs: mg/L VOC Removal%