HomeMy WebLinkAboutWQ0034507_Application (FTSE)_20091204MCDAVID ASSOCIATES' INC. Engineers • Planners • Land Surveyors CORPORATE OFFICE (252) 753-2139 • Fax (252) 753-7220 E-mail: mai@mcdavid-inc.com 3714 N. Main Street • P.O. Drawer 49 Farmville, NC 27828 December 2, 2009 Mr. Al Hodge Environmental Regional Supervisor Washington Regional Office Division .of Water Quality 943 Washington Square Mall Washington, North Carolina 27889 GOLDSBORO OFFICE (919) 736-7630 • Fax (919) 735-7351 E-mail: maigold@mcdavid-inc.com 109 E. Walnut Street • P.O. Box 1776 Goldsboro, NC 27533 DEC 0 4 2009 Subject: Fast Track Application Fork Township Sanitary District Kangaroo Pump Station & Force Main Wayne County, North Carolina Dear Mr. Hodge: The Fork Township Sanitary District requires a permit to construct a pump station and force main. Please find attached two copies of the following items supporting their request: 1. Fast -Track Application (EFTA 12/07 ver5) 2. Check in the amount of $480.00 from The Pantry (Check No. 594698, dated 08/13/09) 3. FTSE Form completed by Fork Township Sanitary District to address their downstream pump station 4. FTSD Form completed by City of Goldsboro to address their downstream pump stations and their acceptance of the flow at the WWTP 5. USGS Topographic Map 6. Watershed Classification Form 7. Variance Request Letter from Fork Township Sanitary District 8. Plans and Specifications 9. Design Notes We look forward to a permit in the near future. Should you have any questions, do not hesitate to call me. Sincerely, McDAVID ASSOCIATES, INC. Cecil G. adden, Jr., P.E. Goldsboro Office Attachments Cc: Fork Township Sanitary District Mr. Todd Grinolds, The Pantry, Inc. W:\D I OXX_GEN\D I00X_MSW1D I 005_CORRES_MSW\CGM\20091FI'SD - KANGAROO\TRANSMITTAL OF APPLICATION TO DWQ.DOC Fork Township Sanitary District P.O. Box 1515 Goldsboro, North Carolina 27533 (919) 736-2551 December 1, 2009 Mr. Adrian Eaton Division of Water Quality 1617 Mail Service Center Raleigh, NC 27699-1617 Subject: Variance Request Pump Station Design Criteria Kangaroo Pump Station Fork Township Sanitary District Wayne County, NC Dear Mr. Eaton, The purpose of this letter is to request a variance. 15A NCAC 02T .0305 (h) (4) states, "The Public shall be restricted access to the site and equipment." In this case the Kangaroo Convenience Store is currently served by two septic tanks piped in series with a single grinder pump placed in the final chamber of the second tank. The pump then doses a nitrification field. Access to the single pump is simply by removing a manhole lid. We propose to replace the simplex pump with dual grinder pumps, in the same pump chamber; and direct the flow to an existing force main owned and operated by the District. Controls will be inside a locked stainless steel NEMA 4X control panel. Access to the pumps will continue to be made by removing a manhole lid. The tanks are located in the store's parking lot under 6-inches of concrete. It is not appropriate to fence in the area. Providing a locking mechanism could result in a hazard to customers' tires. The existing facility has been in existence for greater than 12 years with no incidents of vandalism. We propose to drill and tap the lid and rim directly above the pump chamber to restrict access. A picture is attached to show you the existing situation. Your approval of this request for variance will be appreciated. If you have any questions concerning this, please do not hesitate to contact me, or our engineers. Sincerely, FORK TOWNSHIPS ITARY DISTRICT AAA) enry Braswell Chairman C:\DOCUMENTS AND SETTINGS \ENG-I2\LOCAL SETTINGS\TEMPORARY INTERNET FILES \CONTENT.IE5\PZIIZXJS\REQUEST FOR VARIANCE.DOC osewbod EXISTING 8 eade5w. PROPOSED FTSD KANGAROO PUMP STATION AND 2" FORCE MAIN WAYNE COUNTY SN• NOVEMBER 2009 uth Center • OF A7 State of North Carolina Department of Environment and Natural Resources 7 Division of Water Quality DEC 0 4 2009 FAST -TRACK APPLICATION (FTA 12/07 ver5) for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS (Pressure & Vacuum sewer systems are not to he included as part of this application package) INSTRUCTIONS: Indicate that you have included/addressed the following list of required application package items by checking the space provided next to each applicable item. Failure to submit all required items will lead to your application being returned as incomplete. Forms are available from the web site or by calling the Regional Office serving your county: http://h2o. enr. state. nc. us/percs/Collection%20Systems/CollectionSystemApplications. html ® A. Application Form - Submit one original and one copy of the completed and appropriately executed application form. The application should include a project narrative describing the final build -out design (i.e. system and/or pump station to ultimately serve 500 homes, but flow for only 100 homes being requested now). For modifications, clearly explain the reason for the modification (i.e. adding another phase, changing line size/length, etc.). Only include the modified information in this permit application - do not duplicate project information that has already been included in the original permit. Any changes to this form will result in the application being returned. The Division of Water Quality (Division) will only accept application packages that have been fully completed with all applicable items addressed. You do not need to submit detailed plans and specifications unless you respond NO to Item B(13). Separate applications should be made for non-contiguous sewer systems. ® B. Application Fee - Submit a check in the amount of $480 made payable to: North Carolina Department of Environment and Natural Resources (NCDENR). Checks shall be dated within 90 days of application submittal. ❑ C. Certificates of Public Convenience and Necessity — If the application is being submitted in the name of a privately -owned public utility, submit two copies of the Certificate of Public Convenience and Necessity (CPCN) which demonstrates that the public utility is authorized to hold the utility franchise for the area to be served by the sewer extension. If a CPCN has not been issued, provide two copies of a letter from the North Carolina Utilities Commission's Public Staff that states that an application for a franchise has been received, that the service area is contiguous to an existing franchised area, and/or that franchise approval is expected. The project name in the CPCN or letter must match that provided in Item A(2)a of this application. ❑ D. Operational Agreements — Submit one original and two copies of a properly executed operational agreement, as per 15A NCAC 02T .0115, if the application is submitted by a private applicant and will be serving residential or commercial lots (e.g., houses, condominiums, townhomes, outparcels, etc.) that will be sold to another entity. If the applicant is a home or property owner's association, use Form HOA 02/03. If the applicant is a developer, use Form DEV 02/03. EVEN IF THE PROJECT MAY BE TURNED OVER TO A MUNICIPALITY UPON COMPLETION, FORM DEV 02/03 IS REQUIRED. ® E. Downstream Sewer, WWTF Capacity and Flow Tracking/Acceptance — FORM FTSE 10/07 (Flow Tracking/Acceptance for Sewer Extension Permit Applications) is required with every application. The applicant (and owners of downstream sewers, pump stations and/or treatment facilities submitting FORM FTSE-10/07) certifies that the addition of the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving treatment plant, and that the flow from this project will not cause capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving wastewater treatment plant. Where the applicant is not the owner of the downstream sewer, submit two copies of FORM FTSE 10/07 from the owner of the downstream sewer and owner of the WWTF, if different. The flow acceptance indicated in FORM FTSE-10/07 must not expire prior to permit issuance and must be dated less than one year prior to the application date. Submittal of this application and FORM FTSE-10/07 indicates that owner has adequate capacity and will not violate G.S. 143-215.67(a). Intergovernmental agreements or other contracts will not be accepted in lieu of project -specific FTSE 10/07. F Map — Submit an 8.5-inch by 11-inch COLOR copy of a USGS Topographic Map of sufficient scale to identify the entire project area and the closest surface waters. Each map or maps must show the location of the sewer line and pump stations and be of reproducible quality. Include a street level map showing the downstream connection point, and the permit number for the downstream sewer, if known. WADI OXX_GEN\DIOOX_MSW\DII0)5_CORRES_MSW\CGM\20091FTSD - KANGAROO\ KANGAROO APPLICATION ETA_ I 2-07_VER5.DOC • • G. Stream Classifications — Watershed Classification Attachment (Form WSCAS-12/07) If any portion of the sewer system project is within 100 feet of any surface water or wetlands, the Watershed Classification Attachment may need to be completed. A variance must be requested for encroachment within required setbacks or buffers pursuant to 2T .0305 (f) and be indicated in Item B-13 with supporting documentation/justification provided. ❑ H Environmental Assessments — If this project is subject to an Environmental Assessment (EA) [15A NCAC O1C], this application cannot be used. Send the project application on the most current version of Form PSFMGSA to the Design Management Unit, 1633 Mail Service Center, Raleigh, NC 27699-1633. Applications cannot be accepted until a Finding of No Significant Impact (FONSI) or Environmental Impact Statement (EIS) has been issued. A copy is to be submitted with that permit application. ❑ I. Flow Direction — Many wastewater treatment systems are entering into agreements for regionalization efforts and emergency treatment capacity. Parts of the system are installed so that the wastewater flow can be directed to more than one treatment facility. If this is the case with this project, please indicate in B(12) and give the permit number of the second treatment facility. ® J. Certifications — Section C The application must be certified by both the applicant and the design engineer who is a North Carolina Registered Professional Engineer (PE). The applicant signature must match the signing official listed in Item A(1b). The PE should NOT certify the application if he/she is unfamiliar with 15A NCAC Chapter 2T, the Gravity Sewer Minimum Design Criteria (most recent version) and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains (most recent version), as applicable to the project. THE COMPLETED FTA 12/07 APPLICATION PACKAGE, INCLUDING ALL SUPPORTING DOCUMENTS AND $480 FEE, SHOULD BE SENT TO THE APPROPRIATE REGIONAL OFFICE: REGIONAL OFFICE ADDRESS COUNTIES SERVED Asheville Regional Office 2090 US Highway 70 Swannanoa, North Carolina 28778 (828) 296-4500 (828) 299-7043 Fax Avery, Buncombe, Burke, Caldwell, Cherokee, Clay, Graham, Haywood, Henderson, Jackson, Macon, Madison, McDowell, Mitchell, Polk, Rutherford, Swain, Transylvania, Yancey Fayetteville Regional Office 225 Green Street Suite 714 Fayetteville, North Carolina 28301-5094 (910) 433-3300 (910) 486-0707 Fax Anson, Bladen, Cumberland, Harnett, Hoke, Montgomery, Moore, Robeson, Richmond, Sampson, Scotland Mooresville Regional Office 610 E. Center Avenue Mooresville, North Carolina 28115 (704) 663-1699 (704) 663-6040 Fax Alexander, Caban-us, Catawba, Cleveland, Gaston, Iredell, Lincoln, Mecklenburg, Rowan, Stanly, Union Raleigh Regional Office 1628 Mail Service Center Raleigh, North Carolina 27699-1628 (919) 791-4200 (919) 788-7159 Fax Chatham, Durham, Edgecombe, Franklin, Granville, Halifax, Johnston, Lee, Nash, Northampton, Orange, Person, Vance, Wake, Warren, Wilson Washington Regional Office 943 Washington Square Mall Washington, North Carolina 27889 (252) 946-6481 (252) 975-3716 Fax Beaufort, Bertie, Camden, Chowan, Craven, Currituck, Dare, Gates, Greene, Hertford, Hyde, Jones, Lenoir, Martin, Pamlico, Pasquotank, Perquimans, Pitt, Tyrrell, Washington, Wayne Wilmington Regional Office 127 Cardinal Drive Extension Wilmington, North Carolina 28405 (910) 796-7215 (910) 350-2004 Fax Brunswick, Carteret, Columbus, Duplin, New Hanover, Onslow, Pender Winston-Salem Regional Office 585 Waughtown Street Winston-Salem, North Carolina 27107 (336) 771-5000 (336) 771-4630 Fax Alamance, Alleghany, Ashe, Caswell, Davidson, Davie, Forsyth, Guilford, Rockingham, Randolph, Stokes, Surry, Watauga, Wilkes, Yadkin For more information, please visit our web site at: http://h2o. enr. state. nc. us/peresJCollection % 20Systems/Col/ectionSystemsHome.html or contact the Regional Office serving your county. W:\DIOXX GEN\DIOOX MSW\DIOOS CORRES MSW\CGM\2(X)9\FTSD - KANGAROO\ KANGAROO APPLICATION FTA I2-07 VER5.DOC USE THE TAB KEY TO MOVE FROM FIELD TO FIELD! Application Number: (to be completed by DWQ) -� O 0 39-ro 7 Z 0 a 0 LI_ Z Z 0 F— a V J a a Z 0 H cL 0 Ll. Z H re W a m 1. Owner/Permittee: la. Fork Township Sanitary District Full Legal Name (company, municipality, HOA, utility, etc.) lb. Henry Braswell, Chairman Signing Official Name and Title (Please review 15A NCAC 2T .0106 (b) for authorized signing officials!) 1 c. The legal entity who will own this system is: ❑ Individual ❑ Federal ❑ Municipality ❑ State/County 0 Private Partnership 0 Corporation ® Other (specify): San. Di. ld. Fork Township Sanitary District, P.O. Box 1515 le. Goldsboro Mailing Address City 1f. North Carolina State lh. (919) 736-2551 li. (919) 735-6565 Telephone Facsimile 2. Project (Facility) Information: 2a. Kangaroo Pump Station & Force Main Brief Project Name (permit will refer to this name) 3. Contact Person: 3a. Tony McCabe lg. 27533 1j. Zip Code E-mail 2b. Wayne County County Where Project is Located Name and Affiliation of Someone Who Can Answer Questions About this Application 3b. (919) 736-2551 Phone Number 3c. ftsd2@bellsouth.net E-mail 1. Project is ® New 0 Modification (of an existing permit) If Modification, Permit No.: 2. Owner is ® Public (skip to Item B(3)) 0 Private (go to Item 2(a)) 2a. If private, applicant will be: ❑ Retaining Ownership (i.e. store, church, single office, etc.) or ❑ Leasing units (lots, townhomes, etc. - skip to Item B(3)) ❑ Selling units (lots, townhomes, etc. - go to Item B(2b)) 3. City of Goldsboro 2b. If sold, facilities owned by a (must choose one) ❑ Public Utility (Instruction C) ❑ Homeowner Assoc./Developer (Instruction D) Owner of Wastewater Treatment Facility (WWTF) Treating Wastewater From This Project 4a. Goldsboro WWTP 4b. NC 0023949 5a. Name of WWTF Fork Township San. Dist. 5b. 8-inch Owner of Downstream Sewer Receiving Sewer Size 6. The origin of this wastewater is (check all that apply): ❑ Residential Subdivision ❑ Apartments/Condominiums ❑ Mobile Home Park ❑ School ❑ Restaurant ❑ Office ❑ Gravity ® Force Main WWTF Permit No. 5c. WQ 0031A74 Permit # of Downstream Sewer (Instruction E) ❑ Retail (Stores, shopping centers) ❑ Institution ❑ Hospital ❑ Church ❑ Nursing Home ❑ Other (specify): Convenience Store with food preparation. 100 % Domestic/Commercial % Industrial (attach description.) (RO: contact your Regional Office Pretreatment staff) Other (specify): 7. Volume of wastewater to be allocated or permitted for this particular project: 2,185 gallons per day *Do not include future flows or previously permitted allocations (60 gal/100 sf) x 3642 sf. 8. If the permitted flow is zero, indicate why: N/A ❑ Pump Station, Outfall or Interceptor Line where flow will be permitted in subsequent permits that connect to this line 0 Flow has already been allocated in Permit No. ❑ Rehabilitation or replacement of existing sewer with no new flow expected (see 15A NCAC 02T .0303 to determine if a permit is required) W:\DIOXX GEN\DI00X MSW\DI005 CORRES MSW\CGM\2009\FTSD-KANGAROO\ KANGAROO APPLICATION F A I2-07 VER5.DOC 9. Provide the wastewater flow calculations used in determining the permitted flow in accordance with 15A NCAC 2T .0114 for the value in Item B(7) AND/OR the design flow for line or pump station sizing if a reduced or zero flow is being requested in Item B(7). Values other than that in 15A NCAC 2T .0114 (b) and (c) must be supported with actual water or wastewater use data in accordance with 15A NCAC 2T .0114 (f). 3,642 gal x (60 gal/100sf) = 2,185 gpd 10. Summary of Sewer Lines to be Permitted (attach additional sheets if necessary) Size (inches) 2-inches Length (feet) New Gravity or Additional Force Main 1,490 feet T 2,$ A . % Force Main in 11. Summary of Pump Stations wl associated Force Mains to be Permitted (attach additional sheets as necessary) W M Pump Station Location ID Kangaroo Pump Station (self chosen - as shown on plans/map for reference) Design Flow Operational Point Power Reliability Option Z (MGD) GPM @TDH 1 - permanent generator w/ATS; Force Main Size Force Main Length 0 2 - portable generator wIMTS V .002185 mgd ADF Tributary 30 GPM @ 55.88' 2 — and 24 hours storage 2-inches 1.490 ft Z 0 l Pump Station Location ID NA (self chosen - as shown on plans/map for reference) Q B. PERMIT Design Flow Operational Point Power Reliability Option (MGD) GPM @TDH 1 - permanent generator w/ATS; Force Main Size Force Main Length 2 - portable generator w/MTS Pump Station Location ID NA (self chosen - as shown on planslmap for reference) Design Flow (MGD) Operational Point GPM @TDH Power Reliability Option 1 - permanent generator w/ATS; Force Main Size Force Main Length 2 - portable generator w/MTS 12. Will the wastewater flow in the proposed sewer lines or pump stations be able to be directed to another treatment facility? ] Yes ® No If Yes, permit number of 2'd treatment facility RO — if "yes" to B,12 please contact the Central Office PERCS Unit) 13. Does the sewer system comply with the Minimum Design Criteria for the Fast Track Permitting of Pump Stations and Force Mains (latest version), the Gravity Sewer Minimum Design Criteria (latest version) and 15A NCAC Chapter 2T as applicable? ❑ Yes ® No If No, please reference the pertinent minimum design criteria or regulation and indicate why a variance is requested. SUBMIT TWO COPIES OF PLANS, SPECIFICATIONS OR CALCULATIONS O k' h y PERTINENT TO THE VARIANCE WITH YOUR APPLICATION rZ 4ccess to the wetwell is by a bolted down manhole cover. The wetwell is existing and is under 6" of paving in an existing parking lot. Installing a locking cover may be hazardous to customer's tires. The facility has been in place pi ILA 1.0 12(►0 Ioiej AIt1/4vCj1 yl0 (L i1uu i'tw1r111 r,,.1 )11 uuLAtr100.-1 ricer ePr�av�C�. W:\DIOXX GEN\DIOOX MSW\DI005 CORRES MSW\CGM\2009\FI'SD - KANGAROO\KANGAROO APPLICATION FTA I2-07 VERS.DOC 14. Have the following permits/certifications been submitted for approval for the system or project to be served? Wetland/Stream Crossings - General Permit or 401Certification? Sedimentation and Erosion Control Plan? Stormwater? ❑ Yes ❑ No ❑ Yes ❑ No ❑ Yes ❑ No ® N/A Directional Bore ® N/A Less than one acre. ® N/A 15. Does this project include any high priority lines, [see 15A NCAC 02T .0402 (2)] involve aerial lines, siphons, or interference manholes)? These lines will be considered high priority and must be checked once every six months Check if Yes: ❑ and provide details N.A. 1. Owner/Permittee's Certification: (Signature of Signing Official and Project Name) 1, Henry Braswell, Chairman , attest that this application for the Kangaroo Pump Station & Force Main has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being retumed as incomplete. Note: in accordance with North Carolina General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as /yell as civil penaltiM up to $25, 000 per violation. gning Official Sighat re i2-2-o5 Date ENGINEERING DESIGN DOCUMENTS MUST BE COMPLETED PRIOR TO SUBMITTAL OF THIS APPLICATION. THESE DOCUMENTS MUST INCLUDE PLAN AND PROFILE OF SEWERS, THEIR PROXIMITY TO OTHER UTILITIES, DESIGN CALCULATIONS. ETC. REFER TO 15A NCAC 02T .0305 2. Professional Engineer's Certification: (Signature of Design Engineer and Project Name) 1, _Cecil G. Madden, Jr., P.E. , attest that this application for Kangaroo Pump Station & Force Main has been reviewed by me and is accurate, complete and consistent with the information in the engineering plans, calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers adopted February 12, 1996, and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 and the watershed classification in accordance with Division guidance. Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. Note: In accordance with NC General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10, 000 as well as civil penalties up to $25, 000 per violation. 2a. Cecil G. Madden, Jr., P.E. Professional Engineer Name 2b. McDavid Associates, Inc. Engineering Firm 2c. P.O. Box 1776 Mailing Address 2d. Goldsboro City 2g. (919) 736-7630 2h. (919) 7335-7351 2i. E-mail Telephone Facsimile = SEAV QU ▪ t 1635 e s 2e. NC 2f. 27533 .<2- °°� � �;���•` • State Zip `P000�BG. wiAD0,0%) cgm@mcdavid-inc.com NC PE Seal, Signature & ate C:\DOCUMENTS AND SETTINGS \TONY\LOCAL SETTINGS',l [MPORARY INTERNET FILES\CONTENT.IE5\P3TQYOTO\KANGAROO_APPLICATION_PTA_12-07_VER5[ I ].000' FORM WSCAS-12/07 WATERSHED CLASSIFICATION ATTACHMENT FOR SEWER SYSTEMS Applicant Name Project Name Fork Township Sanitary District (FTSD) Kangaroo Pump Station & FM Professional Engineer Name Engineering Firm Name Cecil G. Madden, Jr. McDavid Associates, Inc. Goldsboro Office Location ID Name of Waterbody' County River Basin Waterbody Stream Index No. Waterbody Classification 1 Unnamed Tributary to Cogdell's Pond which is Tributary to "The Canal" Wayne NEUSE 27-57-21.3 C; NSW DEC 0 4 20G9 If unnamed, indicate "unnamed tributary to X", where Xis the named waterbody to which the unnamed tributary joins. 1 certify that as a Registered Professional Engineer in the State of North Carolina that I have diligently followed the Division's instructions for classifying waterbodies and that the above classifications are inclusive of the stated project, complete and correct to the best of my knowledge and belief. PE Seal, Signature and Date *** END OF FORM WSCAS-12/07 *** ©? FORM: WSCAS-12/07 Page 1 of 1 • NC DENR - DIVISON OF WATER QUALITY .0315 NEUSE RIVER BASIN 2B .0300 Name of Stream Class Description Class Date Index No. Dennis Branch Mill Creek Buck Swamp Peacock Branch Smith Mill Run Little River Little River The Canal Little River Little River From source to Little River WS-IV;NSW 08/03/92 27-57-20.5 From source to Little River WS-IV;NSW 08/03/92 27-57-20.7 From source to Mill Creek WS-IV;NSW 08/03/92 27-57-20.7-1 From source to Buck Swamp WS-IV;NSW 08/03/92 27-57-20.7-1-1 From source to Little River WS-IV;NSW 08/03/92 27-57-21 From a point 0.6 mile WS-IV;NSW,CA 08/03/92 27-57-(21.1) downstream of Smith Mill Run to City of Goldsboro water supply intake From City of Goldsboro C;NSW 08/03/92 27-57-(21.2) water supply intake to U.S. Hwy. 70 From source to Little River C;NSW From U. S. Highway 70 to a B;NSW point 1.0 mile downstream from U. S. Highway 70 08/03/92 27-57-21.3 08/03/92 27-57-(21.4) From a point 1.0 mile C;NSW 08/03/92 27-57-(22) downstream from U.S. 70 to Neuse River Borden Field Ditch From source to Little River C;NSW 05/01/88 27-57-23 Big Ditch From source to Neuse River C;NSW 05/01/88 27-58 Neuse River Cut -Off From source to Neuse River C;NSW 05/01/88 27-59 Poplar Branch From source to dam at Gold B;NSW 05/01/88 27-60-(1) Park lake Poplar Branch From dam at Gold Park Lake C;NSW 05/01/88 27-60-(2) to Neuse River Caraway Creek From source to Neuse River C;NSW Unnamed Tributary at Camp From source to dam at Camp B;NSW Traillee Traillee Lake 05/01/88 27-61 ' 05/01/88 27-61-1-(1) Unnamed Tributary at Camp From dam at Camp Traillee C;NSW 05/01/88 27-61-1-(2) Traillee Lake to Caraway Creek Stoney Creek From source to Neuse River C;NSW 05/01/88 27-62 Stoney Run From source to Stoney Creek C;NSW 05/01/88 27-62-0.5 Howell Creek From source to Stoney Creek C;NSW 05/01/88 27-62-1 Reedy Branch From source to Stoney Creek C;NSW 05/01/88 27-62-2 Billy Branch From source to Stoney Creek C;NSW 05/01/88 27-62-3 Fellows Branch From source to Neuse River C;NSW 05/01/88 27-63 Green Branch From source to Neuse River C;NSW 05/01/88 27-64 Pine Level Branch From source to Neuse River C;NSW 05/01/88 27-65 Cabin Branch From source to Neuse River C;NSW 05/01/88 27-66 Sleepy Creek From source to lower dam at B;NSW 05/01/88 27-67-(1) Camp Carver Lake Sleepy Creek Burnt Mill Branch Burnt Mill Branch From lower dam at Camp C;NSW 05/01/88 27-67-(2) Carver Lake to Neuse River From source to dam at Camp B;NSW 05/01/88 27-67-3-(1) Tuscarora Lake From dam at Camp Tuscarora C;NSW 05/01/88 27-67-3-(2) Lake to Sleepy Creek Page 20 of 43 2009-10-31 06:22:20 State of North Carolina PG Department of Environment and Natural Resources 7 Division of Water Quality Flow Tracking/Acceptance for Sewer Extension Permit Applications (FTSE —10/07) Project Applicant Name: Fork Township Sanitary District Project Name for which flow is being requested: Kangaroo Pump Station & Force Main More than one FTSE-10/07 may be required for a single project if the owner of the WWTP is not responsible for all pump stations along the route of the proposed wastewater flow. I. Complete this section only if you are the owner of the wastewater treatment plant. a. WWTP Facility Name: b. WWTP Facility Permit #: DEC 0 4, 2009 All flows are in MGD c. WWTP facility's permitted flow d. Estimated obligated flow not yet tributary to the WWTP e. WWTP facility's actual avg. flow f. Total flow for this specific request g. Total actual and obligated flows to the facility h. Percent of permitted flow used II. Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow. List pump stations located between the project connection point and the WWTP Pump Station Name Pump Station No. 2 Approx. Capacity, MGD Approx. Current Avg. (Firm/Design) Daily Flow, MGD 0.576 MGD . O 1 2- III. Certification Statement: I, I4 IJi2 j, ajsz eJ ( , certify that, to the best of my knowledge, the addition of the volume of watewater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items listed above in Sections I and II for which 1 am the responsible party. Signature of this form indicates acce nce of this astewater flow. L L4 /Z-2_09 Date Signing Of_ficibl Signa re TF9 State of North Carolina OG Department of Environment and Natural Resources Division of Water Quality Flow Tracking/Acceptance for Sewer Extension Permit Applications (FTSE —10/07) Project Applicant Name: Fork Township Sanitary District Project Name for which flow is being requested: Kangaroo Pump Station & Force Main More than one FTSE-10/07 may be required for a single project if the owner of the WWTP is not responsible for all pump stations along the route of the proposed wastewater flow. I. Complete this section only if you are the owner of the wastewater treatment plant. a. WWTP Facility Name: City of Goldsboro Water Reclamation Facility b. WWTP Facility Permit #: NC0023494 c. WWTP facility's permitted flow d. Estimated obligated flow not yet tributary to the WWTP e. WWTP facility's actual avg. flow f. Total flow for this specific request g. Total actual and obligated flows to the facility h. Percent of permitted flow used DEC 0 4 2009 All flows are in MGD 14.2 0.0424 6.79 0.0022 6.8346 48.1% II. Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow. List pump stations located between the project connection point and the WWTP Pump Station Name Approx. Capacity, MGD Approx. Current Avg. (Firm/Design) Daily Flow, MGD Little Cherry 0.65 MGD Big Cherry 1.0 MGD Highway 117 7.1 MGD Westbrook 18 MGD 0.003 MGD 0.004 MGD 0.22 MGD 6.79 MGD III. Certification Statement: I, Joseph R. Huffman, certify that, to the best of my knowledge, the addition of the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items listed above in Sections I and II for which I am the responsible party. Signature of this form indicates acceptance of this wastewate fl w. IC�ICII J / 2 -o 2 -og Si. ' ' g ignature Date I\\ 75 Tee c c.o s E5 3-" FLoca:›iDutr- E. tf Trailer Park Meaddw. Spring Hill Ch mouth Center -65 7" \ .\ i \<.` acor 1 filer ark Vocational -Training Center Radiod To • Security 77 75 // .• h Zi