Loading...
HomeMy WebLinkAboutNC0058891_Staff Report_19940217NPDES DOCUHENT SCANNING COVER SHEET NC0058891 Valley Creek WWTP NPDES Permit: Document Type: Permit Issuance Wasteload Allocation Authorization to Construct (AtC) Permit Modification Complete File - Historical Engineering Alternatives (EAA) Correspondence Owner Name Change ,, Staff Report Instream Assessment (67b) Speculative Limits Environmental Assessment (EA) Document Date: February 17, 1994 This document is printed CM reuse paper - ignore amity contest on the reverse side cc: Permits and Engineering Technical Support Branch County Health Dept. Central Files WSRO SOC PRIORITY PROJECT: To: Permits and Engineering Unit Water Quality Section Attention: Susan Wilson Date: February 17, 1994 NPDES STAFF REPORT AND RECOMMENDATION County Watauga Permit No. NC0058891 PART I - GENERAL INFORMATION 1. Facility and Address: Mr. Robert A. Kent, General Partner Kent & Kent Partnership Kent & Kent Valley Creek WWTP 230 Glen Lake Drive Atlanta, GA 30327 2. Date of Investigation: February 15, 1994 3. Report Prepared by: Mike Mickey, Envirn. Specialist II 4. Persons Contacted and Telephone Number: Mr. Leonard Cotton, Jr., President (Ski Hawksnest) ph (704)963-6561 Mr. Rusty Trammel, Hydrologic, ph (704)733-9498 5. Directions to Site: Turn right onto SR 1151 off Hwy 105 (near Foscoe) and proceed toward the Seven Devils Town Hall. Continue on SR 1151 past the Town Hall approximately 0.8 mile to the Hanging Rock Villas on the left. After turning in to the Villas, the WWTP is to the right and down the hill. 6. Discharge Points(s), List for all discharge points: Latitude: 36° 08' 50" Longitude: 81° 48' 43" U.S.G.S. Quad No. C-11-NE U.S.G.S. Quad Name Valle Crucis 7. Site size and expansion area consistent w/ application? Yes 8. Topography (relationship to flood plain included): The WWTP is located on the side of a hill and well above the flood plain. 9. Location of nearest dwelling: The Hanging Rock Villas are located approximately 400 feet up the mountain from the WWTP. 10. Receiving stream or affected surface waters: Valley Creek a. Classification C-trout b. River Basin and Subbasin No.: 04-02-01 c. Describe receiving stream features and pertinent downstream uses: Valley Creek is a scenic rocky stream located in a steep isolated valley. The Ski Hawksnest Resort and Golf Club is located 0.5 mile upstream of the WWTP outfall. The Country House Village WWTP (NC0033448) discharges into Valley Creek approximately 0.7 mile downstream from the Kent facility. Part II - DESCRIPTION OF DISCHARGE AND TREATMENT WORKS 1. a. Volume of Wastewater to be permitted: 0.01 MGD b. What is the current permitted capacity of the Waste Water Treatment facility? 0.01 MGD. (A review of self -monitoring data for the period 4/93 - 11/93 shows an average flow of 0.0055 MGD). c. Actual treatment capacity of the current facility (current design capacity)? 0.01 MGD d. Date(s) and construction activities allowed by previous A/C's issued in the previous two years: NA e. Please provide a description of existing or substantially constructed wastewater treatment facilities; The 0.01 MGD package consists of bar screen, aeration basin, clarifier with sludge return, sludge holding, tablet chlorinator, contact chamber and rearation chamber for chlorine reduction. f. Please provide a description of proposed wastewater treatment facilities. NA g. Possible toxic impacts to surface waters: None known. h. Pretreatment Program (POTWs only): NA 2. Residuals handling and utilization/disposal scheme: a. Other disposal/utilization scheme (Specify): Sludge cannot be pumped at present. Hopefully, the WWTP will be accessible to a pumper truck in the near future. NPDES Permit Staff Report Version 10/92 Page 2 3. Treatment plant classification (See attached rating sheet). Class II (34 points) 4. SIC Code(s): 4952 Primary 06 Secondary 13 Main Treatment Unit Code: 0 6 0 X 7 PART III - OTHER PERTINENT INFORMATION 1. Is this facility being constructed with Construction Grant Funds or public monies. (municipals only)? NA 2. Special monitoring or other requests: Observations of the package plant revealed a serious oil and grease problem. It is recommended that an oil and grease limit be incorporated into the new permit in order to require the facility to address the problem. See additional requests in Part IV below. 3. Important SOC, JOC or Compliance Schedule dates: NA 4. Alternative Analysis Evaluation: NA for existing facility with positive flow stream. PART IV - EVALUATION AND RECOMMENDATIONS The Kent Valley Creek WWTP receives wastewater from the Hanging Rock Villas which consist of six buildings with a total of twenty-four units (12 two bedroom and 12 one bedroom). The villas are served by the Town of Seven Devils water system. The average discharge from the WWTP is 5,500 gpd. Please note that Sewer Extension Permit No. WQ0008154, was issued on January 14, 1994, allowing the connection of an additional 4,460 gpd into the Kent Valley Creek WWTP from Ski Hawksnest Resort and Golf Club. The Golf Club is presently served by a failing ground absorption system. The permit was issued for "construction only" and WSRO has advised Ski Hawksnest that the additional wastewater cannot become tributary until previous deficiencies are corrected and the system is in compliance. A review of self monitoring data shows consistent TSS violations for the past year. The facility was assessed $2,316.44 (LV 93-047) on 12/3/93 for the TSS violations. The noncompliance was due to the fact that the plant is inaccessible (no road) to pumper trucks and solids cannot be removed. NPDES Permit Staff Report Version 10/92 Page 3 • The accuracy of the flow values reported on the monitoring forms are questionable since the existing ISCO flow meter and v- notch/rectangular weir (installed without an A/C) is not capable of measuring flows up to the 0.01 MGD permit limit. It was also noted that effluent flow was bypassing around the in pipe weir since it was not properly caulked. The site evaluation found several deficiencies that need to be addressed by the new permit. Therefore, the following clauses should be inserted into Part III: 1) A suitable road must be constructed to the treatment plant within 180 days after reissuance in order to allow adequate access for a pumper truck to reach the facility for routine solids pumping. 2) Plans and Specifications and a request for Authorization to Construct for the installation of a suitable flow measuring device must be submitted within 90 days of reissuance. The new flow meter must be installed within 180 days after reissuance. 3) The spare blower must be repaired and made operational within 90 days after reissuance. 4) Grating must be installed over the treatment plant and a railing must be installed around the sides of the treatment plant within 180 days of reissuance in order to insure the safety of the operators and DEM staff. WSRO recommends reissuance provided that the above clauses and an oil and grease limit are incorporated into the new permit. Signature of report pre pa r /`o4-Water Quality Regional Supervisor Date NPDES Permit Staff Report Version 10/92 Page 4