Loading...
HomeMy WebLinkAbout20220190 Ver 1_More Information Received_20220524Strickland, Bev From: John R. Davis, Jr. <soilhorizons@gmail.com> Sent: Tuesday, May 24, 2022 7:28 PM To: Barnes, Kyle W CIV USARMY CESAW (USA); Cohn, Colleen M Subject: [External] Fwd: Waters Edge- rev plans Attachments: WatersEdge Boathouse Excerpts 052422.pdf CAUTION: External email. Do not click links or open attachments unless you verify. Send all suspicious email as an attachment to Report Spam. Kyle and Colleen, Please see the attached revised plans for 6032 Water Edge Drive. We have reduced the size to confirm with permit requirements. Thanks John John R. Davis, Jr. LSS Soil Horizons 919-818-5087 www.soilhorizons.net PO Box 1063 Youngsville, NC 27596 Fax 919-554-2363 http://sites.google.com/site/soilhorizonsinc/ Like us on Facebook! Soil Horizons Forwarded message From: David Revoir <drevoir@appianengineers.com> Date: Tue, May 24, 2022 at 1:57 PM Subject: Waters Edge- rev plans To: John R. Davis, Jr. <soilhorizons@gmail.com> John- Attached are the revised plans as discussed. David C. Revoir, PE Appian Consulting Engineers, PA 1 154 Roundabout Court/ PO Box 7966 Rocky Mount, NC 27804 www.appianengineers.com 252.972.7703 Appian Consulting Engineers, PA, is a dynamic consulting firm of engineers and designers providing Civil, Structural, and Municipal Engineering to local, regional, and national clients. This electronic communication and its attachments are forwarded to you for convenience. If this electronic transmittal contains design information or recommendations and not just general correspondence, Appian Consulting Engineers, PA., will submit a follow-up hard copy via mail or delivery for your records, and this hard copy will serve as a final record. In the event of conflict between electronic and hard copy documents, the hard copy will govern. This e-mail and any attachments transmitted with it are the property of Appian Consulting Engineers, PA and may contain information that is confidential or otherwise protected from disclosure. The information it contains is intended solely for the use of the one to whom it is addressed, and any other recipient should destroy all copies. 2 � C rti •� u 00 I N `D yF, I a J I N y EX EDGE�� WATER AT 3' SHORELINE 128.48 (12-22-21) y� f 100'R PRO TOP OF SRW _ BULKHEAD = 128.06 CITY OF ��--� ROCKY MOUNT - r RESERVOIR I 1 SCALE: 1" = 10' 1 , 0 10 20 25 30 35 40 l``{l I ex concrete 91.85� rLv,n found � .— .-. — — — — . ly ♦ 1 1 � t + 94 1 I f I I } � 1 f _ \ o Cs. ` • r } 6' ' 4 SS 8 J CAP (GLUED W/ EXTERIOR �� j L J �a°N' 7 CONSTRUCTION ADHESIVE 5% k SLOPE 5O, W+DE BAR- g' 1g PRO TOW = 128.06 \I PAM BUFFER KEYSTONE BLOOI{NTYPE: E STANDARD III // /f\ L ¢ F d a,. CLAY CAP ¢ e - � rr• 132 C14 132 Y Y .-'- I ❑ a eq co ❑ o (0II LLI N 2 r ❑ ❑ y ❑ L is- 0 _ f I 13a s a o -'" I 130 r r o a LL L` r r o O oI 0 _ _ 7 m r 128 r r PRO TOP WALL = 128.06 i _ ,� 128 r-�� _ r 126 L7 EX. TIMBER BULKHEAD BEYOND �I I 2.25' 126 !G , � !NORMAL SHORE LINE r ' WATER 12-22-21 (124.48t) 124 — 124 MATERIAL TO BE EXCAVATED I 00, a iv (SEE BULKHEAD NOTES!) in � 122 _-—_--74122 �r,r PRO TOP LEVELING BASE 121.73 LEGEND I EX. GRADE - - - - - - - - - - SCALES. 120 1 1 1" = 2' VERR 120 ME d / ¢ d \r Q LAP \\ 12" TYP. COMPACTED GRANULAR 4 ° d FILL (SAND CLAY -TYPE LSC,SM)5/8" OFFSET4AYER 2 d l 4 4 ° r LAP � ° e 4 " #57 STONE �. o !� 125.48f (12-22-21) e Q \ Q� MIRAGRID 3XT QF\\�i� fQJ�' GEOGRID 4.47' 4 �r� ' Cr REINFORCING ° LAYER 1 O ♦ �`��� d °L ! LAP d d e L ! —NONWOVEN -1I I ¢ ¢ ° L FILTER FABRIC d 3' 4 4 / O ,moo STONE— (���OQO f 1�o � LEVELING BASE/A AAA 24" - 5'-0" 1 00 SEGMENTAL RETAINING WALL 'innnr 9 FRI�0 � ,4 CONSULTING ENGINEERS, P.A. CIVIL, MUNICIPAL & STRUCTURAL ENGINEERS BLN = C0562 154 Roundabout Cf. P.O. Box 7966 Rocky Mount, N.C. 27804 Phone: (252) 972-7703 www.appionengineers.com cidmin@cippianengineers.com Final Drawings Review Purposes ONLY C ■ o ■ U Co ■� Cc cl) Cc cc ow MID m W " ■jri/ J ■ ■ au o ■w z ED — N 0 o C o C 0 o 0 L 0 GC 21 -056 D-0000 S-1 E NOTES: 1. MINIMUM FLOOR JOIST SIZE = 2x6 ag 16" O.C. LARGER JOISTS MAY BE USED AT CONTRACTORS OPTION. 2. NAIL SECURELY LAPPED FLOOR JOISTS. LEGEND . INDICATES 6x6 PT PILE SOLID THRU TO ROOF ® INDICATES 6x6 PT PILE STOPS BELOW FLOOR DECKING 1 6 DENOTES MAXIMUM PILE AXIAL DESIGN LOAD (D L) IN KIPS (1,000# = 1K) C4 DENOTES BOLTING 1 CONNECTION DETAIL. INDICATES X-BRACING BAY JH SIMPSON GALVANIZED JOIST HANGER DG DROP GIRDER - TYPICAL D.F.J. DOUBLE FLOOR JOIST CONNECTIONS TO BE 5/8" DIA. GALV. AB (C4) UNLESS SHOWN OTHERWISE. ALL BOLTS TO BE 518" DIA. HDG UNLESS A SHOWN OTHERWISE MAXIMUM BOAT WEIGHT = 4,000 LBS. OR BOAT LIFT CAPACITY, A WHICHEVER IS LESS. IT IS RECOMMENDED CONTRACTOR POST LIMIT AT BOAT HOUSE. DUE TO THE CORROSIVE NATURE OF THE PRESENT PRESERVATIVE TREATMENT, STAINLESS STEEL FASTENERS AND PLATE CONNECTORS ARE STRONGLY RECOMMENDED OVER HOT DIP GALVANIZED. CURRENT PRESERVATIVE TREATMENT (ASQ OR CA) IS 2 TO 3 TIMES AS CORROSIVE AS THE FORMER CCA TREATMENT FORMULATION (USED PRIOR TO 2003). These plans are for bidding purposes only and are not to be used as Construction drawings unless initialed and dated as approved for Construction below by the Engineer. Approved for Construction: Date: RECORD DRAWINGS: These drawings are believed to be a correct representation of actual field conditions but are not warranted as such. By: Date: CONSTRUCTION SAFETY These drawings do not contain the requirements for job safety. All provisions for safety shall be the sole responsibility of the contractor. EXISTING CONDITIONS: The contractor shall be responsible for reviewing all existing job conditions. Any adverse existing conditions affecting work shown on these drawings shall be brought to the attention of the engineer for possible clarification or reconciliation. ADA AND LEGAL DISCLAIMER This document is not represented to comply with all requirements contained in the ADA or other laws. Engineers are not licensed to interpret laws or give advice concerning laws, the owner should have this document reviewed by his attorney to determine legal compliance. u- +I CV co 0 Z Y U W N C4 Co [V a 12 Z Q cc co x ry C4(3!4") QD�t� --- 0.82 - — - (2) 2x8's - — DROP GIRDER �x8 gA�O� - L o Q.97 cX 6'-0" DECKING 1.25 i 1.25 5'-3 1 /2" a w b a a 6 m n a PRO SRW BULKHEAD - SEE WALL SECTION lf? - — SEE DETAIL 1 �1 FOR STEPS (4) 2x8's DROP GIRDER Z a m 00 x [V C4(3!4"} (2) 2x8's DROP GIRDER a.55 96D 2x8 BAND c� ❑ --.> d z co 0o g (0 p x p �� 1.28 a a.63 N � U C3B 2x8 BND o CV , o io SEE FND. NOTE 7 TYPICAL (2) 2x8's DROP GIRDER C3B z Q fn m u- 0 N LO °D ❑ Q to N `r° FJ LAP OVER GIRDER m00 EXTEND FJ PAST (2) 2x8's N OPPOSITE GIRDER AND NAIL DROP GIRDER C3B 1.33 1,1$ C4(3!4"} 4'-1 1/2" 12'-0" CLEAR DECKING A -A S2 u- 0 x r N r (2) 2x8's DROP GIRDER 2x8 BAND 5 3/4" 0-0 11L �I= 12'-8 112" TOTAL 16'-11 112" WATER FLOW DIRECTION cn (2) 2x8's DROP 0.2 GIRDER 0.6 a I. 0 0.83 z Y L.] W or z ❑ ❑ �a Q ❑ Q J Z C� N U m Co cX `n N 9 CD co a.8 0.4 2x8 BAND c� LO 4 114" +I M u 5 3/4" BOATHOUSE 1 DOCK = 486.1 SF. PILE and GIRDER FRAMING PLAN SCALE: 114" = V-0" SCALE: 1 /4" = 1'-0" 0 4 8 10 12 14 16 '1nririr 0 ,4 19 90FRI CONSULTING ENGINEERS, P.A. CIVIL, MUNICIPAL & STRUCTURAL ENGINEERS BLN = C0562 154 Roundabout Ct. P.O. Box 7966 Rocky Mount, N.C. 27804 E Phone: (252) 972-7703 N www.appionengineers.com admin@appianengineers.com Final Drawings Review Purposes ONLY 0 v E x a 0 CL ME NOT FOR CONSTRUCTION o 0 Q 4 Z Q N N 4 N J IN C IN a A n 0 V d) 3 0 Z W ca N z LL N ca z N 0 W ° ati i v � 0 N 0 0 9 a � w 0 caN 0 W t� J o� ° L N a U o a` 21 --056 D-0000CL a S-3 N r UNLESS APPROVED BY ENGINEER, DO NOT ENCLOSE BOAT HOUSE. FRAMING NOT DESIGNED TO RESIST WIND LOADS IMPOSED BY WALLED ENCLOSURE OTHER THAN AS SHOWN. ADDITIONAL BRACING & PILE UPLIFT CAPACITY WILL BE NEEDED. NOTIFY ENGINEER IF WALLS ARE DESIRED FOR DIRECTIONS. CONSTRUCTION SAFETY These drawings do not contain the requirements for job safety. All provisions for safety shall be the sole responsibility of the contractor. EXISTING CONDITIONS: The contractor shall be responsible for reviewing all existing job conditions. Any adverse existing conditions affecting work shown on these drawings shall be brought to the attention of the engineer for possible clarification or reconciliation. ADA AND LEGAL DISCLAIMER This document is not represented to comply with all requirements contained in the ADA or other laws. Engineers are not licensed to interpret laws or give advice concerning laws, the owner should have this document reviewed by his attorney to determine legal compliance. 1'-0" O.H. 2x6 PT DECKING PT 2x6 FLOOR JOISTS @ 16" O.C. - TYPICAL BAND (SEE _ FRAMING PLAN) 1 &C9 I 1 4'-1 112" DECKING (nts) FLOOR JOIST UPLIFT TIE- (1) PER BAY TYPICAL SEE DETAIL C10 2x6 BRACING ® (SEE FRAMING PLAN FOR BAYS TO BE BRACED) (SEE FDN. NOTE 7 - TYP.) 3'-3 112" (n.t.s. These plans are for bidding purposes only and are not to be used as Construction drawings unless initialed and dated as approved for Construction below by the Engineer. Approved for Construction: Date: RECORD DRAWINGS: These drawings are believed to be a correct representation of actual field conditions but are not warranted as such. By: Date: RIDGE VENT 2x8 RIDGE 12 5 2x4 COLLAR TIE @ 48" O.C. 7116" PLYWOOD CEILING * PROVIDE ATTIC ACCESS & TYPE AT LOCATION APPROVED BY OWNER CONNECTION i3 (SEE FRAMING PLAN) 2x8 RAFTERS @ 16" O.C.- 2x6 CEILING JOISTS @ 16" D.C. BOAT WEIGHT IS NOT TO AEXCEED LIFT CAPACITY OR 4,000#, WHICHEVER IS LESS CAUTION OWNER: �j DO NOT RIDE BOAT LIFT DURING !� RAISING OR LOWERING OF BOAT 12'-0" CLEAR DOUBLE PT GIRDER (SEE FRAMING PLAN FOR SIZE) MEAN WATER LEVEE 6x6 PILE TYPICAL ADD 6x6 BLOCK WHEN DIRECTED BY ENGINEER 'IB UNDER WATER LOWER BRACING ATTACHMENT: USE BOLTS WHEN WATER IS DOWN OTHERWISE, ATTACH BY HAMMER USING (6) 16d RING SHANK NAILS. A 12'-8 112" 16'-0" (nts SEE GENERAL NOTES FOR MINIMUM PILE BURY AND REQ'D LOAD RATING. NOTE: FRAMING SYSTEM DESIGNED FOR 3 FPS WATER VELOCITY FIBERGLASS SHINGLES OVER 15# FELT HURRICANE CLIPS (32" D.C. J 24" D.C. IF —TRUSSES USED) GALVANIZED DRIP FLASHING 314" FASCIA BOARD SOFFIT VENT 1/2" SHEATHING (32/16 RATED)(NAIL WITH 8d @ 6" O.C. EDGES AND 12" O.C. INTERIOR O 100 YR. BFE 10" DECKING BAND (SEE FRAMING PLAN) +I N TRANSVERSE SECTION of BOAT HOUSE NOT TO SCALE ® MAXIMUM BOAT WEIGHT = 4,000 LBS. OR BOAT LIFT CAPACITY, WHICHEVER IS LESS - IT IS RECOMMENDED CONTRACTOR POST LIMIT AT BOAT HOUSE. w of Q 'innnr 19 9 FRI 0 At ,4 CONSULTING ENGINEERS, P.A. CIVIL, MUNICIPAL & STRUCTURAL ENGINEERS BLN = C0562 154 Roundabout Ct. P.O. Box 7966 Rocky Mount, N.C. 27804 0 Phone: (252) 972-7703 N www.appionengineers.com admin@appianengineers.com Final Drawings Review Purposes ONLY 0 v E S. a 0 CL ME NOT FOR CONSTRUCTION low N O I N N 4 N V n Z 0 I V i 0 N W car N W Z Q c Q N W = 4) cc N Z W ati Co CM o w Z e o� 9 a00 w 0 0 o� a L N I U 0 a` 21-056 D-0000CL a S-5 N