Loading...
HomeMy WebLinkAbout20220190 Ver 1_More Information Received_20220503Strickland, Bev From: John R. Davis, Jr. <soilhorizons@gmail.com> Sent: Tuesday, May 3, 2022 4:17 PM To: Barnes, Kyle W CIV USARMY CESAW (USA); Cohn, Colleen M Subject: [External] Fwd: Waters Edge- rev plans for permitting Attachments: Waters Edge S1 rev050322.pdf; Waters Edge S3 rev050322.pdf CAUTION: External email. Do not click links or open attachments unless you verify. Send all suspicious email as an attachment to Report Spam. Kyle and Colleen, The engineers and client were able to revise the project at 6032 Waters Edge Drive to fall within the limits of the general permits. Please see the attached and let me know if you have any questions or concerns and confirm receipt. Thanks for your patience with the project. John John R. Davis, Jr. LSS Soil Horizons 919-818-5087 www.soilhorizons.net PO Box 1063 Youngsville, NC 27596 Fax 919-554-2363 http://sites.google.com/site/soilhorizonsinc/ Like us on Facebook! Soil Horizons Forwarded message From: David Revoir <drevoir@appianengineers.com> Date: Tue, May 3, 2022 at 9:10 AM Subject: Waters Edge- rev plans for permitting To: John R. Davis, Jr. <soilhorizons@gmail.com> Cc: <donnie@millsmarineshiprepair.com>, Bobby Joyner <bjoyner@appianengineers.com> John- Revised plans for environmental permitting attached. Areas of the dock/boathouse are shown on bottom left of sheet S3, and are below the new general permit maximum thresholds. Let us know if you have any concerns about this getting approved.... i THANKS! David C. Revoir, PE Appian Consulting Engineers, PA 154 Roundabout Court/ PO Box 7966 Rocky Mount, NC 27804 www.appianengineers.com 252.972.7703 2 t � s � Y rti 6' i v 00 ow r yF, I a J � N y ■ i EX EDGE�� WATER AT 3' r SHORELINE 128.48 (12-22-21) r ■ ■ ■ j 100'R .f PRO TOP OF SRW - _ BULKHEAD = 128.06 CITY OF -�--� ROCKY MOUNT - r RESERVOIR i 1+ 1 1 SCALE: 1" = 10' I m { , 0 10 20 25 30 35 40 I 0 a ex concrete l w = — 91.85 , L__ found — - — — — -- co o C i hl ❑ V d Z 7 o> t Ld 1 c t + { LLJ F 1' o a c / f o o j { 1 w s 4 oa ■ a J i ¢ Q 7 94 C ry p f 4 N 1 1 Q O �4 r 9 C7 0 Cl 4 I 1 r r J 'v II m a 0 V CONSULTING ENGINEERS, P.A. = f 1 CIVIL, MUNICIPAL & STRUCTURAL ENGINEERS BLN = C0562 �' i ;�f 1 fir."�s� '• 154 Roundabout cf. P.O. BOX 7966 `- I Rocky Mount, N.C. 27804 Phone: (252) 972-7703 www.a pp is n e n g i neerS.00M admin@cippianengineers.Com I J y � .Y �►1 a'• `� ` ss0-38'pa.ew CAP (GLUED W/ EXTERIOR 5�;+OE I L 7g 1g �, CONSTRUCTION ADHESIVE 5% SLOPE SEA ro �AR_PAM BUFFE PRO TOW = 12&06 8421 R KEYSTONE RETAINING WALL BLOCK TYPE: STANDARD III N \\�/ �\��/\ `LNG Ii��F�' {c.�: 0 L ° F 1 i 6 8" CLAY CAP \\�/ !' �0 35 � rr• 132 C14 -' 132 Y . I d � OD II w N _��• a a } v r }• W W 0 I 130 s s a •-' 130 r ❑I m r wl 1281 r PRO TOP WALL = 128.06 i _ 128 n. /� iH N 1 ' 12s G EX. TIMBER BULKHEAD BEYOND I I 2.25' ' � G 12� NORMAL SHORE LINE WATER 12-22-21 (124.48t) 124 — MATERIAL TO BE EXCAVATED I rr r 124 (SEE BULKHEAD NOTES!) u7 r- r r Cv r 122 _ -_'r _ — _ -- I PRO TOP LEVELING BASE 121.73 LEGEND 122 I EX. GRADE---------- - SCALES. 120 1" = 2' VERR 120 d / d \/ o d Q LAP \\ ° 12" TYP COMPACTED GRANULAR d d FILL (SAND CLAY -TYPE ~ V SC,SM) .� 5/8" OFFSET ° a 4 LAYER 2 � d l q [ LAP ` a ! d ! e e 4 ##57 STONE O� d 125.48t (12-22-21 ) e a N � �Q MIRAGRID 3XT GRID 4.47' \�' 4 c,� RE� FORCING e d LAYER 1 O ! LAP d d e e L ! ° a 4 L n l! +NONWOVEN — —III—III d r FILTER FABRIC rL , 4 E STONE L � LEVELIELI NG BASE 24" - 5'-0" I- 1 DO SEGMENTAL RETAINING WALL SCALE: 1 "=1'-0" ��\/\/ fffffffffffff U — \\ � ffffffffff,� // ■ C � � r� ■� a N o 0 ■� V A) MID Z0 �W� PCN I, LD rn N ZLD O Lf 1 0 Q1 N 0 V L� .� cm o _0 = v) C N ♦♦�� d >b V o o 0 a CL oICL p Lo � a a V) N 0 21 —056 D-0000 0 S-1 NOTES: 1. MINIMUM FLOOR JOIST SIZE = 2x6 a� 16" O.C. LARGER JOISTS MAY BE USED AT CONTRACTORS OPTION. 2. NAIL SECURELY LAPPED FLOOR JOISTS. LEGEND . INDICATES 6x6 PT PILE SOLID THRU TO ROOF ® INDICATES 6x6 PT PILE STOPS BELOW FLOOR DECKING 1 6 DENOTES MAXIMUM PILE AXIAL DESIGN LOAD (D L) IN KIPS (1,000# = 1K) C4 DENOTES BOLTING 1 CONNECTION DETAIL. INDICATES X-BRACING BAY JH SIMPSON GALVANIZED JOIST HANGER DG DROP GIRDER - TYPICAL D.F.J. DOUBLE FLOOR JOIST CONNECTIONS TO BE 5/8" DIA. GALV. AB (C4) UNLESS SHOWN OTHERWISE. ALL BOLTS TO BE 5/8" DIA. HDG UNLESS SHOWN OTHERWISE MAXIMUM BOAT WEIGHT = 4,000 LBS. OR BOAT LIFT CAPACITY, WHICHEVER IS LESS. IT IS RECOMMENDED CONTRACTOR POST LIMIT AT BOAT HOUSE. DUE TO THE CORROSIVE NATURE OF THE PRESENT PRESERVATIVE TREATMENT, STAINLESS STEEL FASTENERS AND PLATE CONNECTORS ARE STRONGLY RECOMMENDED OVER HOT DIP GALVANIZED. CURRENT PRESERVATIVE TREATMENT (ASQ OR CA) IS 2 TO 3 TIMES AS CORROSIVE AS THE FORMER CCA TREATMENT FORMULATION (USED PRIOR TO 2003). These plans are for bidding purposes only and are not to be used as Construction drawings unless initialed and dated as approved for Construction below by the Engineer. Approved for Construction: Date: RECORD DRAWINGS: These drawings are believed to be a correct representation of actual field conditions but are not warranted as such. By: Date: CONSTRUCT10N SAFETY These drawings do not contain the requirements for job safety. All provisions for safety shall be the sole responsibility of the contractor. EXISTWG CONDITIONS: The contractor shall be responsible for reviewing all existing job conditions. Any adverse existing conditions affecting work shown on these drawings shall be brought to the attention of the engineer for possible clarification or reconciliation. ADA AND LEGAL DISCLAIMER This document is not represented to comply with all requirements contained in the ADA or other laws. Engineers are not licensed to interpret laws or give advice concerning laws, the owner should have this document reviewed by his attorney to determine legal compliance. G R>tpP EO v d e 6A�O e a �x8 BULKHEAD - - U SEE WALL SECTION r LL _ - l.L a - > [.4 - 0.97 cv C4 0.97 SEE DETAIL 101 FOR STEPS (4) 2x8's DROP GIRDER d ❑ m ❑ m Li Eo 6?-014 co Co DECKING +I 1.25 1.25 LL d(2) ED 2x8's DROP GIRDER co CV (D - z U w N C? cc "� N LO 80 i r� LO a 5'-3 112" 0.33 I Q•55 N (2) 2x8's DROP GIRDER c"' 0.82 3.0 Q (2) 2x8DROP­ GIRDER Cop C3Bco SEE FND. NOTE 7 TYPICAL 1.1 J ......................... C3B 0 C3B 1.92 z L U m N [Q 00 x N C3B ❑ ----------Q 27 5 314" C15 3.66 1 V-11 112" DECKING � U 0 x N � O 5-3 112" Q.63 WATER FLOW DIRECTION Q.63 2x8 BAND Q 53 z M u_ o cc) Czr Q) x 1.28 0 0.63 C%4 2x8 BND —(2) 2x8's DROP GIRDER 0.68 Of Q U m W FJ LAP OVER GIRDER a co N EXTEND FJ PAST N OPPOSITE GIRDER (2) 2x10's A& AND NAIL DROP GIRDER C4(314"} 1.18 12'-0" CLEAR (2) 2x8's DROP GIRDER 4 114" 12'-8 112" TOTAL 28'-7 112" PILE and GIRDER FRAMING PLAN SCALE: 114" = V-0" 4 114" 0.83 Q.83 _ 4'-8" DECKING L U co D x (D 31 r - Q.4 0.4 1 2x8 BAND u V (2) 2x8's DROP 'n 0 2 GIRDER } N (2) 2x8's DROP m _GIRDER --_-- (2) 2x8's DROP GIRDER z Q coOD - m X LO N -100 (2) 2x8's DROP GIRDER ----_ A -A rJ2 � —(2) 2x8's DROP _GIRDER — — (D z Y U W +I rn a a z Y U W co N +I z, w u 5 314" BOATHOUSE = 322.03 SF. DOCK = 470.16 SF. SCALE: 1 /4" = 1'-0" 0 4 8 10 12 14 16 � I O � a U a7 2 � O �7 Y w = p U N v N C O v 0 0 a 0 (A o w Li r a a � O 4 w n z c) a Q o W J c a U U Q � N a o o z innnr 0 9 FRI 0 4 N CONSULTING ENGINEERS, P.A. 2' CIVIL, MUNICIPAL & STRUCTURAL ENGINEERS G BLN = C0562 154 Roundabout Ct. P.O. Box 7966 ° Rocky Mount, N.C. 27804 6 Phone: (252) 972-7703 www.appionengineers.com admin@appianengineers.com w ? SEAL 8421 ZN �.r�O' Ln V V Z J C , N a �LO 4 LO 0 Ln 6 own, N o ZU ca W c0 zN lD LL N W C� Cc C v C C� 0 Q a .. o C 0 a W t� J 0 n 0 a N 21-056 � D-0000 S-3