HomeMy WebLinkAboutWQ0005247_Inspection_20220927•AOWA
The clear leader.
AMA Inc.
2604 Willis Court, Wilson, NC 27896
Phone: 252-243-7693 — Email: agwatammysanders@gmall.com
Customer Name: Haddock
Address:
Permit No.
Arrival Time
Date of Inspection: 918/2022
Haddock - 804 Perfect Moment Dr (Lot 33) Durham, NC System AX ID: AX-114125
09:00 AM
County:
Departure Time
DWO-Ref
01:30 PM
Inspection and Maintenance Checklist - AX20 (1. 2, or 3) Sub Surface or Surface Drip Dispersal
Septic Tank Inspection
Tank
Tank
At Site Tank 1
1 Inlet Readings Tank 2 Inlet Readings
0 Scum 8 Sludge Scum Sludge
Tank 1 Outlet Readings Tank 2 Outlet Readings
0 Scum 6 Sludge Scum Sludge
ITook 4USVNCtIen Qusatlosla. Tank 1 Tank 2
Clean Effluent Filter Cleaned
Check for Influent or Effluent Blockages: No Blockage
Inspect Tank/Riser for Leaks: None Seen
Control Panel Inspection
Check
Recircular
Pump
Pump Operates In Manual Mode: Yes
Pumps Recirculation Pump 1
1 Timer Settings Pump 2 Timer Settings
0.4 Dose 19.0 Rest Dose Rest
Pump 1 - Counters and Elapsed Time Meters Pump 2 - Counters and Elapsed Time Meters
0.1 CT 17567 ETM CT ETM
Verify
Conduit Seal: Verified
AX20 Treatment Podia) Inspection
AX Treatment
Pod(S) PO11PO2
IPod 111apsallon +s' . - - _ Pod 1 _ Pad 2 Pod 3 Porl.4
Inspect for Pending or Bridging: None None
Check and Record Squirt Height: 3ft 3 ft
Verify Orifice Position and Assess for Clogging: Cleaned Cleaned
Check for Odors: None None
Clean, Brush, Flush Lateral: Done Done
Recheck and Record Squirt Height: 3 ft 3 ft
Flush Pod Throroughly: Done Done
Inspect and Clean Vents: Cleaned Cleaned
f
r
Inspection and Maintenance Checklist - AX20 (1 2. or 3) Sub Surface or Surface Drip Dispersal
Recirculation Tank Inspection
Verify Inlet Flow: No Inflow
Sludge
Operating Property
Inspect Liquid: Normal Level
Record Scum/Sludge Levels:
Inlet Readings: Outlet Readings:
0 Scum 8 Sludge 0 Scum 4
Inspect Tank/Riser for Leakage:
Visually Check RSV end Liquid
Clean Biotube/Pump Vault Filter
Inspect Biotube/Pump Vault Filter
Pull Pump and Clean Screen:
None Seen Verify AM Floats Work:
Level: Normal Verify Audible Alarm Works for High Water float:
Works Properly
Cartridge: Cleaned Verify Neal Wrap of Float and Pump Cords:
Checked
Cartridge: Ok Verify Conduit Seal:
Verified
Not Necessary Verify No Leaking In Piping or Flex Hoses:
None Seen
Ultraviolet Disinfection Unit Inspection
Does System Have a UV?
How Many UV Disinfectant Units
Yes
Present? UV 1
UV DlalrAfeplFnt Unit Inspection UV 1
-
After Disconnecting Power Clean or Replace Bulb As Needed: Replaced
Flush Housing Thoroughly: Flushed
Retum Power and Verify Proper Function: Verified
Field Dosing Tank Inspection
Inspect for Tank/Riser Leakage:
Inspect Liquid' Normal
None Seen
Sludge
Works Property
Level
Record Scum/Sludge Levels:
Inlet Readings: Outlet Readings:
Scum Sludge 0 Scum 0
Visually Check Liquid Level:
Verify No Leaks In Piping or Flax
Inspect Pump Intake
VenfyAll Floats Work:
Normal Verify Audible Alarm Works for High Water float:
Hoses None Seen Verify Neat Wrap of Float and Pump Cords:
Verified
Ok Delivery Rate at Start Up:
8.5
Operating Properly Verify Conduit Seal:
Verified
Drip Irrigation System Inspection
Areas Mowed and Clear of Obstruction.
Area Free of Ponding or Surface
Curtain Drains, Ditches Swales
Control Panel Communication
Yea
Effluent: Yea
Functioning Properly Yes
Checked: No dial tone.
Inspection Notes
Chad Allen
Operator Operators Signature
AQWA AQWA Inc.
2604 Willis Court, Wilson, NC 27896
Phone: 252-243-7693 — Email: agwatammysanders[oflgmail.com
Customer Name: Haddock
Inspector.
Arrival Time:
Chad Men
System:
SD
Date of Inspection: September 6, 2022
Departure Tlme:
Drip Irrigation Maintenance Checklist
Current Readings
I Counter
'Timer
Ruin!!
3186
Filter Flush Zone Flush Zoira I
3084 IMEMBEICEM
Zorre 2
942
Zgrrp 3 Zone 4
0.22
345.09 215.2 15079
16155.44
16228.54
Flow Meter
301380
Previous Inspection Readings
Date of Previous Inspection:
4114/2022
pi Co+ir+ker
Pump
MDMIIII
Filter Flush Zone Flusll Zone 1
3020 950 904
Zone 2
Z0ale 3 Zone a 1
905
Tirnr'r
0.5
338.52 211.27 14765.45
15810.44
16013.23
Flow Meter.
288430
Elapsed Calculations
Elapsed Days:
145
Cotn"tei
rrrner
Pinup
83
Filter Flush Zone Flush Zone 1
84 MEM 22
Zone 2
Zone 3 Zorre 41
18
-0.28
8.57IMMINIIMEEM
345
215.31
f
Total Flow Since
Spin Fitter:
Last Visit: 12950
Number of Days:
Filtrate
145
Average Daily Flow:
No
89.31034483
Cleaned
Return Line:
Zone Testing
Pre 1 ihei SPSr1
Post Filled iPSIj
200e 1
75
Zone 2 Zone 3
n 75
Zous .1
75
71MIII 75
baser01eiGPxli
SI.Ppply 1,$I
9.6
n 9.3
n
70
70
MMEEMIll
IRektign P51
85
IIMINIMI82
111111
Flush 13i1e. GPM
F I, is.I L sup* PSI
Fliish Rehriu PSI
19.2
15
38
20
t
18
Inspection Comments
Leaks fixed Zone#1 (4) Zone#2 (37) Zone #3 (10)
Inspector's Signature