HomeMy WebLinkAboutWQ0005247_Inspection_20220927•AOWA The clear leader. AMA Inc. 2604 Willis Court, Wilson, NC 27896 Phone: 252-243-7693 — Email: agwatammysanders@gmall.com Customer Name: Haddock Address: Permit No. Arrival Time Date of Inspection: 918/2022 Haddock - 804 Perfect Moment Dr (Lot 33) Durham, NC System AX ID: AX-114125 09:00 AM County: Departure Time DWO-Ref 01:30 PM Inspection and Maintenance Checklist - AX20 (1. 2, or 3) Sub Surface or Surface Drip Dispersal Septic Tank Inspection Tank Tank At Site Tank 1 1 Inlet Readings Tank 2 Inlet Readings 0 Scum 8 Sludge Scum Sludge Tank 1 Outlet Readings Tank 2 Outlet Readings 0 Scum 6 Sludge Scum Sludge ITook 4USVNCtIen Qusatlosla. Tank 1 Tank 2 Clean Effluent Filter Cleaned Check for Influent or Effluent Blockages: No Blockage Inspect Tank/Riser for Leaks: None Seen Control Panel Inspection Check Recircular Pump Pump Operates In Manual Mode: Yes Pumps Recirculation Pump 1 1 Timer Settings Pump 2 Timer Settings 0.4 Dose 19.0 Rest Dose Rest Pump 1 - Counters and Elapsed Time Meters Pump 2 - Counters and Elapsed Time Meters 0.1 CT 17567 ETM CT ETM Verify Conduit Seal: Verified AX20 Treatment Podia) Inspection AX Treatment Pod(S) PO11PO2 IPod 111apsallon +s' . - - _ Pod 1 _ Pad 2 Pod 3 Porl.4 Inspect for Pending or Bridging: None None Check and Record Squirt Height: 3ft 3 ft Verify Orifice Position and Assess for Clogging: Cleaned Cleaned Check for Odors: None None Clean, Brush, Flush Lateral: Done Done Recheck and Record Squirt Height: 3 ft 3 ft Flush Pod Throroughly: Done Done Inspect and Clean Vents: Cleaned Cleaned f r Inspection and Maintenance Checklist - AX20 (1 2. or 3) Sub Surface or Surface Drip Dispersal Recirculation Tank Inspection Verify Inlet Flow: No Inflow Sludge Operating Property Inspect Liquid: Normal Level Record Scum/Sludge Levels: Inlet Readings: Outlet Readings: 0 Scum 8 Sludge 0 Scum 4 Inspect Tank/Riser for Leakage: Visually Check RSV end Liquid Clean Biotube/Pump Vault Filter Inspect Biotube/Pump Vault Filter Pull Pump and Clean Screen: None Seen Verify AM Floats Work: Level: Normal Verify Audible Alarm Works for High Water float: Works Properly Cartridge: Cleaned Verify Neal Wrap of Float and Pump Cords: Checked Cartridge: Ok Verify Conduit Seal: Verified Not Necessary Verify No Leaking In Piping or Flex Hoses: None Seen Ultraviolet Disinfection Unit Inspection Does System Have a UV? How Many UV Disinfectant Units Yes Present? UV 1 UV DlalrAfeplFnt Unit Inspection UV 1 - After Disconnecting Power Clean or Replace Bulb As Needed: Replaced Flush Housing Thoroughly: Flushed Retum Power and Verify Proper Function: Verified Field Dosing Tank Inspection Inspect for Tank/Riser Leakage: Inspect Liquid' Normal None Seen Sludge Works Property Level Record Scum/Sludge Levels: Inlet Readings: Outlet Readings: Scum Sludge 0 Scum 0 Visually Check Liquid Level: Verify No Leaks In Piping or Flax Inspect Pump Intake VenfyAll Floats Work: Normal Verify Audible Alarm Works for High Water float: Hoses None Seen Verify Neat Wrap of Float and Pump Cords: Verified Ok Delivery Rate at Start Up: 8.5 Operating Properly Verify Conduit Seal: Verified Drip Irrigation System Inspection Areas Mowed and Clear of Obstruction. Area Free of Ponding or Surface Curtain Drains, Ditches Swales Control Panel Communication Yea Effluent: Yea Functioning Properly Yes Checked: No dial tone. Inspection Notes Chad Allen Operator Operators Signature AQWA AQWA Inc. 2604 Willis Court, Wilson, NC 27896 Phone: 252-243-7693 — Email: agwatammysanders[oflgmail.com Customer Name: Haddock Inspector. Arrival Time: Chad Men System: SD Date of Inspection: September 6, 2022 Departure Tlme: Drip Irrigation Maintenance Checklist Current Readings I Counter 'Timer Ruin!! 3186 Filter Flush Zone Flush Zoira I 3084 IMEMBEICEM Zorre 2 942 Zgrrp 3 Zone 4 0.22 345.09 215.2 15079 16155.44 16228.54 Flow Meter 301380 Previous Inspection Readings Date of Previous Inspection: 4114/2022 pi Co+ir+ker Pump MDMIIII Filter Flush Zone Flusll Zone 1 3020 950 904 Zone 2 Z0ale 3 Zone a 1 905 Tirnr'r 0.5 338.52 211.27 14765.45 15810.44 16013.23 Flow Meter. 288430 Elapsed Calculations Elapsed Days: 145 Cotn"tei rrrner Pinup 83 Filter Flush Zone Flush Zone 1 84 MEM 22 Zone 2 Zone 3 Zorre 41 18 -0.28 8.57IMMINIIMEEM 345 215.31 f Total Flow Since Spin Fitter: Last Visit: 12950 Number of Days: Filtrate 145 Average Daily Flow: No 89.31034483 Cleaned Return Line: Zone Testing Pre 1 ihei SPSr1 Post Filled iPSIj 200e 1 75 Zone 2 Zone 3 n 75 Zous .1 75 71MIII 75 baser01eiGPxli SI.Ppply 1,$I 9.6 n 9.3 n 70 70 MMEEMIll IRektign P51 85 IIMINIMI82 111111 Flush 13i1e. GPM F I, is.I L sup* PSI Fliish Rehriu PSI 19.2 15 38 20 t 18 Inspection Comments Leaks fixed Zone#1 (4) Zone#2 (37) Zone #3 (10) Inspector's Signature