HomeMy WebLinkAboutWQ0005247_Compliance Evaluation Inspection_20220927ROY COOPER
Governor
ELIZABETH S. BISER
Secretary
RI CHARD E. ROG ERS, JR.
Director
Donna F Haddock
604 Perfect Moment Dr.
Durham, NC 27713
NORTH CAROLINA
Envlrotunental Quality
September 26, 2022
Subject: Compliance Evaluation Inspection
Single Family Wastewater Treatment System
Non -Discharge Permit #WQ0020817
Facility: 604 Perfect Moment Dr., SFR
Durham County
Dear Ms. Haddock,
On September 6, 2022, Jim Westcott from the Raleigh Regional Office visited your single-
family residence (SFR) wastewater treatment and irrigation system to evaluate compliance
with the Non -Discharge Permit WQ0020817. The cooperation of the contract staff of AQWA
services was greatly appreciated.
You are permitted to operate a SFR wastewater treatment and irrigation facility consisting
of a 1500 gallon baffled septic tank with effluent filter; two Advantex AX-20 Treatment
units VeriComm control panels; a 7 gallon per minute (GPM) ultraviolet (UV) disinfection
unit a 2500 gallon storage tank; a 2500 gallon dosing tank with a 20 GPM pump and
audio/visual high water alarms; an integrated rain sensor; a 0.37 acre drip irrigation area
with approximately 5,418 linear feet (LF); of drip line containing 2,709 emitters; and all
associated piping, valves, control and appurtances to serve the single-family residence at
604 Perfect Moment Drive, Durham, NC 27713, with no discharge of wastes to surface
waters.
Non -Discharge Permit #WQ0020817 authorizes the continued discharge of up to 600
gallons per day (GPD). The authorized irrigation is in accordance with the effluent limits
and monitoring requirements established within the Non -Discharge Permit. The items
below list the conditions observed.
The current non -discharge permit, which was issued April 8,2021 expired March 31, 2021.
Please ensure that future renewal applications are wnpleted no later than f80 days prior
to the expiration d the permit and submitted as required and listed in section t.
At the time of inspection, the facility was secured, clean and organized. The drip irrigation
field was properly secured with wire fencing and the vegetative cover well maintained.
During the inspection, the following was observed:
1. Schedules: Section 1 (1) of the subject permit requires the permittee shall request
renewal of this permit on official Division forms no later than six months prior to the
expiration of the permit. Upon receipt of the request, the division will review the
adequacy of the facilities therein, and if warranted, will renew the permit for such a
period and under such conditions and limitations as it may deem appropriate. Please
note Rule 15A NCAC 02T .0105(d) requires an updated site map to be submitted with the
permit renewal application (15A NCAC 02T . 0105, 02T .0109, 02T . 0115 (c)]. As of the date
of this letter, the division has not yet received the renewal application. Within 30-days d
receiving this letter, please ca nplete and submit the attached renewal application and
forward the request for renewal application to the division
2 Treatment system operation: The wastewater treatment system shall be effectively
maintained and always operated so there is no discharge to surface waters, nor any
contravention of groundwater or surface water standards. The components and Integrity
d the system are serviced under centred with AQWA services every six mcntha Two
previous service documents were provided to the insoedar at the time d Inspection
detailing the components and frequency d maintenance: The on -site generator Is cycled
for 30 minutes a week each Monday mornings
a) The ultraviolet disinfection unit shall be checked weekly. The lamp(s) and quartz
sleeve(s) shall be cleaned or replaced as needed to ensure proper disinfection.
I15A NCAC 02T .0605(1)1. The UV sleeves were deaned and the UV output at the
control panel was In acceptable range of voltage at the time of inspection.
b) The storage, pump, and alarm system shall be inspected monthly.
(15A NCAC 02T.0108(b)(1)]. The storage compartments recirculation and transfer
pumps were witnessed operating as designed at the time of inspection
c) The irrigation system shall be inspected monthly to make certain of the proper
operation of the drip lines, that the system is free of leaks, that the vegetative
growth allows a proper drip pattern, that the soil is assimilating the disposed
treated wastewater with no surface runoff, and that no objectionable odors are being
generated. 115A NCAC 02T .0108(b)(1)1. The drip Irrigation system of zones 1, 2 and 3
were inspected and observed to have small leaks which were noted and repaired by
the contract staff an site and a final report was submitted to the inspector the next
morning by the AQWA contract staff
d) Pumping the septic tank: You are required to inspect the septic tank at least
annually to determine if solids must be removed or if other maintenance is
necessary. Septic tanks should be pumped out every five years or when the solids
level is found to be more than 1/3 of the liquid depth in the septic tank compartment,
whichever is greater. A contract service company periodically evaluates the status of
the accumulated solids level. At the time d Inspection 9/6/2022, the contract staff
provided a document showing the semi-annual inspection records including the
buildup of material in the system. The solids level was approximately 8#dmaterial
in the primary settling tank.
The wastewater treatment system should be periodically inspected to ensure the treatment
components are always maintained and in good operating order. You are also reminded to
maintain all manit&ing data and associated maintenance regards ansite for a minimum of
three years and available ie fa inspection.
If you have questions or comments about this inspection or the requirements to take
corrective action (if applicable), then please contact Jim Westcott at 919-791-4247 or
james,wcstcott neden.r,gov.
Sincerely,
Vanessa E. Manuel, Assistant Regional Supervisor
Water Quality Regional Operations Section
Raleigh Regional Office
Division of Water Resources, NCDEQ
Attachment(s): Compliance Inspection Report
AQWA inspection report(s)
Renewal application
Cc: Laserfiche