Loading...
HomeMy WebLinkAboutNC0063355_Renewal (Application)_20141008.Ay4m2h NCDENR North Carolina Department of Environment and Natural Resources Pat McCrory Governor Thomas J. Roberts, President & COO Aqua North Carolina, Inc. Killian Crossroads WWTP 202 MacKenan Court Cary, NC 27511 Dear Mr. Roberts: John E. Skvarla, III Secretary October 09, 2014 Subject: Acknowledgement of Permit Renewal Permit NCO063355 Iredell County The NPDES Unit received your permit renewal application on October 08, 2014. A member of the NPDES Unit will review your application. They will contact you if additional information is required to complete your permit renewal. You should expect to receive a draft permit approximately 30 -45 days before your existing permit expires. If you have any additional questions concerning renewal of the subject permit, please contact Derek Denard (919) 807 -6307. Sincerely, W re w TkzA f oiro� Wren Thedford Wastewater Branch cc: Central Files Mooresville Regional Office NPDES Unit 1617 Mail Service Center, Raleigh, North Carolina 27699 -1617 Location: 512 N. Salisbury St Raleigh, North Carolina 27604 Phone: 919 -807 -63001 Fax: 919-807-6492/Customer Service: 1-877-623-6748 Internet:: www.ncwater.ora An Equal OpportunitylAfflrmative Action Employer AOUA September 30, 2014 NCDENR / Division of Water Quality/ NPDES Unit 1617 Mail Service Center Raleigh, NC 27699 -0167 Re: Application for Permit Renewal Aqua North Carolina, Inc. Killian Crossroads WWTP NPDES No. NC0063355 Catawba County Gentlemen: Enclosed are three (3) copies of the completed application Form D- WWTP. This submittal includes the necessary attachments for your office to renew the subject permit. As part of this renewal application, Aqua requests to have A.(3.) Special Condition - Operations (a) removed from the permit. This WWTF has an ongoing exemplary compliance record and as such, Aqua does not see the need or benefit to continue operation of the continuous turbidimeter. Should you need any additional information or assistance, please feel free to contact our Regional Compliance Manager, Michael A. Melton @ 704 - 489 -9404 ext. 57238 or by e -mail at MAMelton@aquaamerica.com. A y errs President & COO Enc 202 MacKenan Court • Cary, North Carolina • 27511 • 919 - 467 -8712 NPDES APPLICATION - FORM D For privately owned treatment systems treating 100% domestic wastewaters <1.0 MGD Mail the complete application to: N. C. DENR / Division of Water Quality / NPDES Unit 1617 Mail Service Center, Raleigh, NC 27699 -1617 NPDES Permit INCO063355 If you are completing this form in computer use the TAB key or the up - down arrows to move from one field to the next. To check the boxes, click your mouse on top of the box. Otherwise, please print or type. 1. Contact Information: Owner Name AQUA NORTH CAROLINA, INC. Facility Name KILLIAN CROSSROADS WWTP Mailing Address 202 MACKENAN COURT City CARY State / Zip Code NC 27511 Telephone Number (919) 653 -5770 Fax Number (919)460 -1788 e -mail Address tjroberts@aquaamerica.com 2. Location of facility producing discharge: Check here if same address as above ❑ Street Address or State Road 4306 MOUNT PLEASANT RD (NCSR 1849) City West of TERRELL State / Zip Code NORTH CAROLINA County CATAWBA 3. Operator Information: Name of the firm, public organization or other entity that operates the facility. (Note that this is not referring to the Operator in Responsible Charge or ORC) Name AQUA NORTH CAROLINA, INC Mailing Address 202 MACKENAN COURT City CARY State / Zip Code NORTH CAROLINA 27511 Telephone Number (919) 653 -5770 Fax Number (919) 460 -1788 1 of 3 Form -D 05108 NPDES APPLICATION - FORM D For privately owned treatment systems treating 100% domestic wastewaters <1.0 MGD 4. Description of wastewater: Facility Generating Wastewater(check all that apply): Industrial ❑ Number of Employees Commercial ® Number of Employees UNK Residential ® Number of Homes 32 School ❑ Number of Students /Staff Other ❑ Explain: Describe the source(s) of wastewater (example: subdivision, mobile home park, shopping centers, restaurants, etc.): This system serves 34 commercial businesses- multi- purpose shopping center- restaurants / 33 residential connections- Subdivision 5. Type of collection system ® Separate (sanitary sewer only) ❑ Combined (storm sewer and sanitary sewer) 6. Outfall Information: Number of separate discharge points 1 Outfall Identification number(s) 001 Is the outfall equipped with a diffuser? ❑ Yes ® No 7. Name of receiving stream(s) (Provide a map shouring the exact location of each outfall): Lake Norman (Catawba River) classified WS -IV & B CA waters in the Catawba River Basin 8. Frequency of Discharge: ® Continuous ❑ Intermittent If intermittent: Days per week discharge occurs: Duration: 9. Describe the treatment system List all installed components, including capacities, provide design removal for BOD, TSS, nitrogen and phosphorus. If the space provided is not sufficient, attach the description of the treatment system in a separate sheet of paper. The 0.05 MGD package plant consist of the following: • 0.025 MGD equalization basin • Flow splitter box w/ bar screen • Dual aeration basins with diffused air • Dual secondary clarifiers Dual tertiary filters • Diffused post aeration • Tablet chlorination with contact chamber • Tablet dechlorination • Cascade post aeration • Aerated sludge holding tank • Stand -by power generator 2 of 3 Form -D 05/08 NPDES APPLICATION - FORM D For privately owned treatment systems treating 100% domestic wastewaters <1.0 MGD 10. Flow Information: Treatment Plant Design flow 0.05 MGD Annual Average daily flow 0.020 MGD (for the previous 3 years) Maximum daily flow 0.044 MGD (for the previous 3 years) 11. Is this facility located on Indian country? ❑ Yes ® No 12. Effluent Data Provide data for the parameters listed. Fecal Coliform, Temperature and pH shall be grab samples, for all other parameters 24 -hour composite sampling shall be used. If more than one analysis is reported, report daily maximum and monthly average. If only one analysis is reported, report as daily maximum. Parameter Daily Maximum Monthly Average Units of Measurement Biochemical Oxygen Demand (130135) 10.7 0.6 MG /L Fecal Coliform 6.0 1.1 #/ 100ML Total Suspended Solids 5.4 0.9 MG /L Temperature (Summer) 27 22.3 °Celsius Temperature (Winter) 19 9.2 ° Celsius pH 7.9 N/A UNITS 13. List all permits, construction approvals and /or applications: Type Permit Number Type Hazardous Waste (RCRA) NESHAPS (CAA) UIC (SDWA) Ocean Dumping (MPRSA) NPDES NCO063355 Dredge or fill (Section 404 or CWA) PSD (CAA) Other Non - attainment program (CAA) 14. APPLICANT CERTIFICATION Permit Number I certify that I am familiar with the information contained in the application and that to the best of my knowledge and belief such information is true, complete, and accurate. Thomas J. Roberts President & Chief Operating Officer Pri a of Person Si ing Title SiL ature of ADT)IicZnt bate North Carolina General Statute 143 -215.6 (b)(2) states: Any person who knowingly makes any false statement representation, or certification in any application, record, report, plan, or other document files or required to be maintained under Article 21 or regulations of the Environmental Management Commission implementing that Article, or who falsifies, tampers with, or knowingly renders inaccurate any recording or monitoring device or method required to be operated or maintained under Article 21 or regulations of the Environmental Management Commission implementing that Article, shall be guilty of a misdemeanor punishable by a fine not to exceed $25,000, or by imprisonment not to exceed six months, or by both. (18 U.S.C. Section 1001 provides a punishment by a fine of not more than $25,000 or imprisonment not more than 5 years, or both, for a similar offense.) 3 of 3 Form -D 05/08 Permit NCO063355 9 - ' " ,•T� +.t�- E L ° -�,�� ; •�� ,may '� �� , AC d , a_ � _�- s ° ` " t t NAME Latitude: 351'34'35" O0• .. il ude: 8 1001'55" - -- Aqua North Carolina, Subbasin: 30832 Killian Crossroads__ AQUA North Carolina. SLUDGE MANAGEMENT PLAN For Aqua North Carolina, Inc. No sludge will be treated on any wastewater treatment plant site operated by Aqua N.C., Western Division Where practical, sludge removed from a Aqua N.C., Western Division facility will be transported via a contract hauler to another Aqua N.C., Western Division facility for the purpose of "seeding" a new or under loaded plant. Unusable (or "dead ") sludge will be removed by a contract hauler and properly disposed of in accordance with NCGS 143- 215.1. Contract haulers used by Aqua N.C., Western Division will be required to report the quantity of sludge transported and identify the location of the proposed disposal site if the sludge is not taken to an existing plant operated by Aqua N.C., Western Division. Aqua N.C., Western Division has not entered into any agreement to accept sludge into its facilities from plants not owned by them. Aqua N.C., Western Division will keep records on the quantity of sludge removed from each facility, the name of the contract hauler, and the destination of the sludge (whether used in another plant or disposed of). The information will be kept on file and will be made available to any regulatory agency having jurisdiction over sludge treatment or disposal. Aqua N.C., Western Division includes all of the facilities under the jurisdiction of the Mooresville Regional Office.