Zone 1 Mitigation required: 657 sq ft (147 for addition plus 72 for workshop times 3)
Zone 2 Mitigation required: 108 sq ft (72 for workshop times 1.5)
Total mitigation required: 765 sq ft
Colleen Cohn
Environmental Specialist II
North Carolina Department of Environmental Quality
Division of Water Resources
Raleigh Regional Office
380o Barrett Drive
Raleigh, NC 27609
Office: 919-791-4258
E-mail correspondence to and from this address maybe subject to the
North Carolina Public Records Law and maybe disclosed to third parties.
From: Cohn, Colleen M
Sent: Wednesday, July 20, 2022 3:14 PM
To: Smith, Cherri L <cherri.smith@ncdenr.gov>
Subject: FW: [External] Re: 1306 Wicklow Drive, Cary
Zone 1 Zone 2 Mitigation
Addition 147 511 441
Workshop 72 72 324
Total 219 583 765
The Workshop is 12x12 with approximately half in each zone. Worked back the math from there.
Colleen Cohn
Environmental Specialist II
North Carolina Department of Environmental Quality
Division of Water Resources
Raleigh Regional Office
380o Barrett Drive
Raleigh, NC 27609
Office: 919-791-4258
E-mail correspondence to and from this address may be subject to the
North Carolina Public Records Law and may be disclosed to third parties.
From: Cohn, Colleen M
Sent: Wednesday, July 20, 2022 2:33 PM
To: Smith, Cherri L <cherri.smith@ncdenr.gov>
Subject: FW: [External] Re: 1306 Wicklow Drive, Cary
Colleen Cohn
Environmental Specialist II
North Carolina Department of Environmental Quality
Division of Water Resources
Raleigh Regional Office
380o Barrett Drive
Raleigh, NC 27609
Office: 919-791-4258
E-mail correspondence to and from this address may be subject to the
North Carolina Public Records Law and may be disclosed to third parties.
From: Jeramie Hockman <jeramie.hockman@gmail.com>
Sent: Monday, June 13, 2022 11:51 AM
To: Cohn, Colleen M <colleen.cohn@ncdenr.gov>
Subject: [External] Re: 1306 Wicklow Drive, Cary
CAUTION: External email. Do not click links or open attachments unless you verify. Send all suspicious email as an attachment to
Report Spam.
Good afternoon!
I have attached a copy of the survey which shows the current deck, storage room and shed. I am also attaching a copy of
the design plan to show what the addition will consist of. The addition will be an additional bedroom, bathroom, laundry
room (which the house currently lacks), and a small living room. I have answered your questions below in red.
I hope you're having a great day!
Jeramie Hockman
919-917-4150 Cell
On Wed, Jun 8, 2022, 2:35 PM Cohn, Colleen M <colleen.cohn@ncdenr.gov> wrote:
Good afternoon!
I am beginning my review of the above referenced project for the above referenced project, and I need some more
information.
1. What is included in the new addition? Are there additional bedrooms (how many)? Living room, laundry room,
etc.? Is an uncovered deck or a covered patio included? Some details as to what exactly is included in the new
addition would be helpful to determine if the impacts fall under "necessary infrastructure" for the residence. If
it is easier to show, please feel free to send in a drawing or sketch (or you can sketch on a copy of the plat
included if that is easier). We are trying to minimize the impacts that may require mitigation in Zone 1. See the
attached survey.
2
2. I'm not understanding where the existing deck is on the plat. Is that the diagonally hatched area surrounding the
existing house? It is shown on the survey I have attached. The patio shown on the design plans will be done
with permeable pavers as to not add to our impervious surface area on the lot.
3. Is the 50 square foot storage building mentioned in the application the 68 sq ft "Frame Storage Building" shown
on the left side of the property? That building is outside of the riparian buffer. The framed storage room is
depicted on the survey that I have attached.
4. I appreciate your architect showing Zones 1 and 2 of the buffer (30 and 50 feet from the stream) on the plat.
Could they please provide the square footage of the addition within each of those zones? I'm looking for the
square footage of the yellow part and the purple part in the below snippet. There is 583 square feet in the 50'
buffer and 219 square feet in the 30' buffer.
0
Thanks,
Colleen Cohn
Environmental Specialist II
3
North Carolina Department of Environmental Quality
Division of Water Resources
Raleigh Regional Office
380o Barrett Drive
Raleigh, NC 27609
Office: 919-791-4258
E-mail correspondence to and from this address may be subject to the
North Carolina Public Records Law and may be disclosed to third parties.
4