Loading...
HomeMy WebLinkAboutNCG520016_Site Inspection Report_20220923EPA United States Environmental Protection Agency Washington, D.C. 20460 Water Compliance Inspection Report Form Approved. OMB No. 2040-0057 Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 N 52 NCG520016 22/09/14 C S31112171819 20 21 66 Inspection Work Days Facility Self-Monitoring Evaluation Rating B1 QA ----------------------Reserved------------------- 3 N67707172 73 74 75 80 Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include POTW name and NPDES permit Number) Old Cardinal Gem Mine 71 Rock Haven Dr Franklin NC 28734 Entry Time/Date Permit Effective Date Exit Time/Date Permit Expiration Date 11:00AM 22/09/14 21/03/01 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) /// Other Facility Data 12:00PM 22/09/14 25/07/31 Name, Address of Responsible Official/Title/Phone and Fax Number Darcel Green,71 Rock Haven Dr Franklin NC 28734//828-369-6673/Contacted No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Records/Reports Facility Site Review Compliance Schedules Effluent/Receiving Waters Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspector(s)Agency/Office/Phone and Fax Numbers Date Brett Laverty DWR/Division of Water Quality/828-296-4500/ Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page#1 DocuSign Envelope ID: 05D13A5E-DCBD-4708-BE5C-4EA1FD7BACE0 9/23/2022 9/23/2022 NPDES yr/mo/day 22/09/14 Inspection Type C3111218 1 Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) The flume/wash area was in operation during the site inspection. Water from the flume discharges into two small settling basins before discharging to Mason Branch, which is a Class C stream. The upper pond was turbid on the day of the inspection. The second settling pond was hard to see because of thick vegetation. The earthen containment berms are visible along Mason Branch. The outfall from the second settling pond is on the property line and directly behind the fire department. The water appeared to be clear and was not causing a turbidity violation in the receiving stream. It is important note the discharge from the second settling pond enters a culvert on the fire department property before discharging to Mason Branch. The culvert on the fire department property appears to have collapsed, which may cause issues in the future. I spoke to Darcel Green about the semi-annual monitoring schedule for flow and turbidity. Ms. Green was unaware of the monitoring requirement but is willing to comply moving forward. I gave her a copy of the permit and indicated that she would be receiving a Notice of Deficiency for failing to monitor. NCG520016 17 (Cont.) Page#2 DocuSign Envelope ID: 05D13A5E-DCBD-4708-BE5C-4EA1FD7BACE0 Permit:NCG520016 Inspection Date:09/14/2022 Owner - Facility: Inspection Type: Old Cardinal Gem Mine Compliance Evaluation Compliance Schedules Yes No NA NE Is there a compliance schedule for this facility? Is the facility compliant with the permit and conditions for the review period? The permit requires semi-annual monitoring for flow and turbidity at the outfall to the stream. The permittee hasn't conducted the required monitoring. Comment: Page#3 DocuSign Envelope ID: 05D13A5E-DCBD-4708-BE5C-4EA1FD7BACE0