Loading...
HomeMy WebLinkAbout820268_NOV-2022-PC-0425_20220922ROY COOPER Governor ELIZABETH S. BISER Secretary RICHARD E. ROGERS, JR. Director NORTH CAROLINA Environmental Quality September 22, 2022 CERTIFIED MAIL RETURN RECEIPT REQUESTED 7020 1810 0002 1109 0929 William Powell 3635 Tomahawk Hwy Harrells, NC 28444-8047 Subject: NOTICE OF VIOLATION Administrative Code 15A NCAC 2T .1304 William Powell Permit No. AWS820268 NOV-2022-PC-0425 Sampson County Dear Mr. William Powell, On August 4, 2022, staff of NC Department of Environmental Quality (DEQ) Division of Water Resources (DWR), Water Quality Regional Operations Section (WQROS) inspected the William Powell Farm #2 waste disposal system. We wish to thank Curtis Barwick, who was present during the inspection, As a result of this notification, you are hereby notified that, having been permitted to have a non - discharge permit for the subject animal waste disposal system pursuant to 15A NCAC 2T .1304, you have been found to be in violation of your permit as follows: GDE NORTH C OLI JA ' omm mr� ep..of o�.i North Carolina Department of Environmental Quality I Division of Water Resources Fayetteville Regional Office 1225 Green St., Suite 714 I Fayetteville, North Carolina 28301-5043 910.433.3300 Page 2 William Powell September 22, 2022 Violation 1: The maximum waste level in lagoons/storage ponds shall not exceed that specified in the facility's CAWMP. At a minimum, maximum waste level for lagoons/storage ponds must not exceed the level that provides adequate storage to contain the 25-year, 24-hour storm event plus an additional one (1) foot of structural freeboard except that there shall be no violation of this condition if: a. there is a storm event more severe than a 25-year, 24-hour event. b. the Permittee is in compliance with its CAWMP; and c. there is at least one (1) foot of structural freeboard. — [15A NCAC 02T .1304(b)] Farms with lagoon and storage pond designs completed after September 1, 1996, storage must also be provided for the heavy rainfall factor (NC NRCS Standard 359) for the lagoons/storage pond. In case of lagoons/storage ponds in series that are gravity fed, the 25-year, 24-hour storm event and/or the heavy rainfall factor storage requirement for the system may be designed into the lowest lagoon/storage in the system. However, adequate freeboard must be designed into the upper lagoons/storage ponds to allow sufficient storage to prevent the waste level from rising into the structural freeboard while the storm water is draining into the lowest structure in the system. — [15A NCAC 02T .1304(b)] (Permit No. 100000 S ection V 2) On August 9, 2022, during your routine compliance inspection it was documented that your lagoon level was at 18 inches, your design start pump level is 19 inches. Based on your pumping records you did not pump during May of 2022 and very little in June and July. Your failure to pump during favorable weather conditions for the past 3 months has caused your lagoon to be in violation of your designed freeboard. Required Corrective Action for Violation 1: Lower your lagoon level as weather permits and follow the Plan of Action that was completed for this lagoon. You should attempt to have the lagoon level at the stop pump level at the end of September because of hurricane season. DE NORTH CAROLINA gaparMeM of Environment,/quay North Carolina Department of Environmental Quality I Division of Water Resources Fayetteville Regional Office 1225 Green Street, Suite 714 I Fayetteville, North Carolina 28301-5043 910-433-3300 Page 3 William Powell September 22, 2022 The Division of Water Resources requests that, in addition to the specified corrective action above, please submit the following items on or before 30 days from receipt of this letter: 1. An explanation from the OIC for this farm regarding how violation occurred. 2. A list from the OIC concerning the steps that will be taken to prevent these violations from occurring in the future. Failure to comply with conditions in a permit may result in a recommendation of enforcement action, to the Director of the Division of Water Quality who may issue a civil penalty assessment of not more that twenty-five thousand ($25,000) dollars against any "person" who violates or fails to act in accordance with the terms, conditions, or requirements of a permit under authority of G.S. 143-215.6A. If you have any questions concerning this Notice, please contact Steve Guyton (910) 303-0151 or me at (910) 433-3336. Sincerely, EDocuSigned by: n A __ 5189C2D3DD5C42B... J. Trent Allen Regional Supervisor Water Quality Regional Operations Section Division of Water Resources cc: FRO Compliance Animal Files-Laserfiche D_E NORTH CAROLINA gaparMeM of Environment,/quay North Carolina Department of Environmental Quality I Division of Water Resources Fayetteville Regional Office 1225 Green Street, Suite 714 I Fayetteville, North Carolina 28301-5043 910-433-3300 DE NORTH CAROLINA gaparMeM of Environment,/quay North Carolina Department of Environmental Quality I Division of Water Resources Fayetteville Regional Office 1225 Green Street, Suite 714 I Fayetteville, North Carolina 28301-5043 910-433-3300