Loading...
HomeMy WebLinkAboutSW6220603_Supplement-EZ Form_20220916SUPPLEMENT-EZ COVER PAGE LOAD SUPPLEMENT FORMS PROJECT WJKNWATION 1 I ftjad Name — — i Pmjed Area ac Coastal Wetland Area ac Suface Water Area sc --- Is Oft projW High or Low Dens -- this project use an off -site SCM? Hamra Sw symm 2 T5 3 0 4 0 5 High B 1130es yes COIKLUNCE tMTH 02H .1 oa(4) 7 WYdth of etated setbacks ffovidledfeet 50 8 Will the vegetated setback remain ed? Yes 9 ff BUA is Proposed in the setback, does k meet NCAC 021-11.1 4 ? NIA 10 Is streambank shgAzation proposed on this project? No NUMBER AND TYPE OF SCMs: 11 Infiltration System 12 Bioretention Cal 13 Wet Pond 14 5tomwmller Wetland 15 Permeable Pamremerd 16 Sand Fiiler- 17 Rainwater Harvestirig (RWH 18 Green Roof 19 Level Spreader -Fitter LS-FS 20 Disconnected Imperviots Surface IS 21 Treatment Swale Pond 23 StormFdter r22 24 Siva Cel 25 Ba r 26 Fltem LOAD SUPPLEMENT FORMS DESIGNER CERTIFICATION 27 Name and Trtie: Jarrod E. Hilliard, PE, CFM, Owner 28 Organization: Hilliard Engineering, PLLC 29 Street address: _ 3417 Winterwind Circle 30 City, State, Zip: Sanford, NC 27330 31 Phone numbers : 919-352-2834 32 1 Ema: jhilliardChilliardengineedng.com Certification Statement I certify, under penalty of law that this SupPlement-El form and all supporting information were prepared under my direction or supervision; that the information provided in the forth is, to the best of my knowledge and belief, true, accurate, and complete; and that the engineering plans, specifications, operation and maintenance agreements and other supporting information are consistent with the information provided here. N����Z CARp��,�� pQ-,•�SSS/p • ���% 2.4 SEAL fir•; 035670 _- /,ppl E1601. 9//b/ZZ Date DRAINAGE AREAS 1 Is Ors a high density project? Yes 2 If so, number of drainage areas=kft 1 3 Does Ors pTiqd have low density areas? No 4 If so, number of low density drainage areas 0 5 Is aRlpart of this project subject to previous rule versions? No FORMS LOADED DRAINAGE AREA INFORMATION Entim SM t 4 Type of SCM 5 Total drainage area fl 326,700 326,700 6 Onsite drainage area ft 326,700 326.700 7 Offsite drainage area ft 8 Total BUA in R 258531 sf 258531 sf 9 New BUA on subdivided lots (subject to permitting) ft 10 New BUA not on subdivided lots (subject to perm") (so 258531 sf 258531 sf 11 Offsite BUA N ft 12 Breakdown of new BUA not on subdivided lots: - Parking ft 117831 sf 117831 sf - Sidewalk ft - Roof ft 1407W sf 140700 sf - Roadwa - Future ft - Other, please specify in the comment ton below fl 13 New infiltrating permeable pavement on subdivided lots ft 14 New infiltrating permeable pavement not on subdivided lots (sq ft) Usting BUA that will remain (not subject to rmitti ft 15 16 E)dsting BUA that is already permitted ft 17 E)dsting BUA that will be removed ft 18 Penoent BUA 79% 79% 19 Design storm inches 20 Design volume of SCM cu ft 21 Calculation method for design volume ADDITIONAL INFORMATION 22 Please use this space to provide any additional information about the drainage area(s): OFF -SITE SCM THE DRAINAGE AREA 1 Drainage area number for this project 2 Master permit number SW6100804 3 Drainage area number from the master permit 1 4 Lot or outparcel number Mini Storage 5 BUA allocated by Master Permit 258531 sf INFORMATION ABOUT THE OFF -SITE SCM 6 Type of off -site SCM Wet Pond 7 Available treatment capacity in the off -site SCM (cu ft) 67707 cf 8 Have deed restrictions limiting the BUA on the site been recorded? No 9 Has an Engineer's Certification for the off -site SCM been submitted to DEo? No 10 Are there any Notices of Violation for the off -site system? No 11 Has the off -site SCM been maintained in accordance with its O&M Plan? No 12 Will the collection system be maintained in its design state and kept clean? Yes ADDITIONAL INFORMATION 13 1 Please use this space to provide any additional information about the off -site SCM(s): One of the outparcels and the residential portion of SW6100804 has not been constructed as of the date of this submission.