HomeMy WebLinkAboutNC0056154_Renewal (Application)_20141009A')��gL NCDENR North Carolina Department of Environment and Natural Resources Pat McCrory Governor Thomas J. Roberts, President & COO Aqua North Carolina, Inc. Bridgeport WWTP 202 MacKenan Court Cary, NC 27511 Dear Mr. Roberts: John E. Skvarla, III Secretary October 09, 2014 Subject: Acknowledgement of Permit Renewal Permit NCO056154 Iredell County The NPDES Unit received your permit renewal application on October 08, 2014. A member of the NPDES Unit will review your application. They will contact you if additional information is required to complete your permit renewal. You should expect to receive a draft permit approximately 30 -45 days before your existing permit expires. If you have any additional questions concerning renewal of the subject permit, please contact Bob Sledge (919) 807 -6398. Sincerely, Wren Thedford Wastewater Branch cc: Central Files Mooresville Regional Office NPDES Unit 1617 Mail Service Center, Raleigh, North Carolina 27699 -1617 Location: 512 N. Salisbury St Raleigh, North Carolina 27604 Phone: 919 -807 -63001 Fax: 919-807-6492/Customer Service: 1-877-623-6748 Internet:: www.ncwater.org An Equal OpportunitylAffirmative Action Employer AQUA September 30, 2014 NCDENR / Division of Water Quality/ NPDES Unit 1617 Mail Service Center Raleigh, NC 27699 -0167 Re: Application for Permit Renewal Aqua North Carolina, Inc. Bridgeport WWTP NPDES No. NC00S61 54 Iredell County Gentlemen: RECEIVED /DENR /DWR OCT O8 2014 Water Quality Permitting Section Enclosed are three (3) copies of the completed application Form D- WWTP. This submittal includes the necessary attachments for your office to renew the subject permit. As part of this renewal application, Aqua requests to have A.(4.) Special Condition - Operations (a) removed from the permit. This WWTF has an ongoing exemplary compliance record and as such, Aqua does not see the need or benefit to continue operation of the continuous turbidimeter. Should you need any additional information or assistance, please feel free to contact our Regional Compliance Manager, Michael A. Melton @ 704 - 489 -9404 ext. 57238 or by e -mail at MAMelton @aquaamerica.com. SipfdreI Tiomas J. R70CIO President & Enc - IbL 202 MacKenan Court • Cary, North Carolina • 27511 • 919 - 467 -8712 NPDES APPLICATION - FORM D For privately owned treatment systems treating 100% domestic wastewaters <1.0 MGD Mail the complete application to: N. C. DENR / Division of Water Quality / NPDES Unit 1617 Mail Service Center, Raleigh, NC 27699 -1617 NPDES Permit NC0056154 If you are completing this form in computer use the TAB key or the up - down arrows to move from one field to the next. To check the boxes, click your mouse on top of the box. Otherwise, please print or type. 1. Contact Information: Owner Name AQUA NORTH CAROLINA, INC. Facility Name BRIDGEPORT WWTP Mailing Address 202 MACKENAN COURT City CARY State / Zip Code NC 27511 IDWR Telephone Number (919) 653 -5770 OCT 0 8 2014 Fax Number (919)460 -1788 Water Quality Permitting sectlon e -mail Address tjroberts@aquaamerica.com 2. Location of facility producing discharge: Check here if same address as above ❑ Street Address or State Road 212 CASTAWAY TRAIL City MOORESVILLE State / Zip Code NORTH CAROLINA /28115 County IREDELL 3. Operator Information: Name of the firm, public organization or other entity that operates the facility. (Note that this is not referring to the Operator in Responsible Charge or ORC) Name AQUA NORTH CAROLINA, INC Mailing Address 202 MACKENAN COURT City CARY State / Zip Code NORTH CAROLINA 27511 Telephone Number (919) 653 -5770 Fax Number (919) 460 -1788 1 of 3 Form -D 05/08 NPDES APPLICATION - FORM D For privately owned treatment systems treating 100% domestic wastewaters <1.0 MGD 4. Description of wastewater: Facility Generating Wastewater(check all that apply): Industrial ❑ Number of Employees Commercial ❑ Number of Employees Residential ® Number of Homes 269 School ❑ Number of Students/ Staff Other ❑ Explain: Describe the source(s) of wastewater (example: subdivision, mobile home park, shopping centers, restaurants, etc.): This system serves residential customers only. 5. Type of collection system ® Separate (sanitary sewer only) ❑ Combined (storm sewer and sanitary sewer) 6. Outfall Information: Number of separate discharge points 1 Outfall Identification number(s) 001 Is the outfall equipped with a diffuser? ❑ Yes ® No 7. Name of receiving stream(s) (Provide a map showing the exact location of each outfall). Lake Norman (Catawba River) classified WS -IV & B CA waters in the Catawba River Basin 8. Frequency of Discharge: ® Continuous ❑ Intermittent If intermittent: Days per week discharge occurs: Duration: 9. Describe the treatment system List all installed components, including capacities, provide design removal for BOD, TSS, nitrogen and phosphorus. If the space provided is not sufficient, attach the description of the treatment system in a separate sheet of paper. The 0.08 MGD package plant consist of the following: • Influent flow equalization tank • Bar screen • Flow splitter box • Dual diffused aeration tanks • Dual clarifiers • Sludge holding tank • Tertiary filter Dual tablet disinfection units • Dechlorination facilities • Effluent flow recorder with totalizer • Post - aeration • Effluent pumps • Standby power generator 2 of 3 Form -D 05/08 NPDES APPLICATION - FORM D For privately owned treatment systems treating 100% domestic wastewaters <1.0 MGD 10. Flow Information: Treatment Plant Design flow 0.08 MGD Annual Average daily flow 0.040 MGD (for the previous 3 years) Maximum daily flow 0.090 MGD (for the previous 3 years) 11. Is this facility located on Indian country? ❑ Yes ® No 12. Effluent Data Provide data for the parameters listed. Fecal Coliform, Temperature and pH shall be grab samples, for all other parameters 24 -hour composite sampling shall be used. If more than one analysis is reported, report daily maximum and monthly average. If only one analysis is reported, report as daily maximum. Parameter Daily Maximum Monthly Average Units of Measurement Biochemical Oxygen Demand (BODs) 7.4 0.8 MG /L Fecal Coliform 250 4.6 #/ 100ML Total Suspended Solids 9.0 3.3 MG /L Temperature (Summer) 26 23.3 'Celsius Temperature (Winter) 19 14.8 ° Celsius pH 8.0 N/A UNITS 13. List all permits, construction approvals and /or applications: Type Permit Number Type Hazardous Waste (RCRA) NESHAPS (CAA) UIC (SDWA) Ocean Dumping (MPRSA) NPDES NCO056154 Dredge or fill (Section 404 or CWA) PSD (CAA) Other Non - attainment program (CAA) 14. APPLICANT CERTIFICATION Permit Number I certify that I am familiar with the information contained in the application and that to the best of my knowledge and belief such information is true, complete, and accurate. nayffe of Pers FA ture of Appligfifnt Tit North Carolina General ftatute 143 -215.6 (b)(2) states: Any person who knowingly makes any false statement representation, or certification in any application, record, report, plan, or other document files or required to be maintained under Article 21 or regulations of the Environmental Management Commission implementing that Article, or who falsifies, tampers with, or knowingly renders inaccurate any recording or monitoring device or method required to be operated or maintained under Article 21 or regulations of the Environmental Management Commission implementing that Article, shall be guilty of a misdemeanor punishable by a fine not to exceed $25,000, or by imprisonment not to exceed six months, or by both. (18 U.S.C. Section 1001 provides a punishment by a fine of not more than $25,000 or imprisonment not more than 5 years, or both, for a similar offense.) 3 of 3 Form -D 05/08 Permit NCO056154 Latitude: 35431'15" Facility Longitude: 80952"13" NC0056154 Quadh E15SE Location,. . Receiving Stream: Lake Norman Aqua North Carolina, Inc- Stream Class: WS-Iv & B CA Subbasin:30832 Bridgeport Subdivision North SCALE 1:2400 0 AQUA ` North Carolina. SLUDGE MANAGEMENT PLAN For Aqua North Carolina, Inc. No sludge will be treated on any wastewater treatment plant site operated by Aqua N.C., Western Division Where practical, sludge removed from a Aqua N.C., Western Division facility will be transported via a contract hauler to another Aqua N.C., Western Division facility for the purpose of "seeding" a new or under loaded plant. Unusable (or "dead ") sludge will be removed by a contract hauler and properly disposed of in accordance with NCGS 143- 215.1. Contract haulers used by Aqua N.C., Western Division will be required to report the quantity of sludge transported and identify the location of the proposed disposal site if the sludge is not taken to an existing plant operated by Aqua N.C., Western Division. Aqua N.C., Western Division has not entered into any agreement to accept sludge into its facilities from plants not owned by them. Aqua N.C., Western Division will keep records on the quantity of sludge removed from each facility, the name of the contract hauler, and the destination of the sludge (whether used in another plant or disposed oo. The information will be kept on file and will be made available to any regulatory agency having jurisdiction over sludge treatment or disposal. Aqua N.C., Western Division includes all of the facilities under the jurisdiction of the Mooresville Regional Office.