Loading...
HomeMy WebLinkAboutWQ0013348_NOV-2022-PC-0531_20220920ROY COOPER EUZABETH S. BISER Secretory RICHARD E ROGERS, JR. NORTH CAROUNA Eirrtrorernentat Quality Certified Mail # 7019 2970 0.001 33.40 2156 Return Receipt Requested September 20, 2022 Eric Harper, Superintendent Bay River Metropolitan Sewer District PO Box 758 Bayboro, NC 28515-0758 SUBJECT: NOTICE OF VIOLATION Tracking Number: NOV-2022-PC-0531 Permit No. WQ0013348 Pamlico Regional WWTFs Pamlico County Dear Mr. Harper: The North Carolina Division of Water Resources conducted an inspection of the Pamlico Regional WWTFs on September 19, 2022. This inspection was conducted to verify that the facility is operating in compliance with the conditions and limitations spedfied in Non -discharge Permit No. WQ0013348. A summary of the flndings and comments noted during the inspection are provided in the enclosed copy of the inspection report. The Compliance Evaluation inspection was conducted by Division of Water Resources staff from the Washington Regional Office. The following violation were noted during the inspection: Inspection Area Description of Violation Treatment Lagoons The three Oriental facultative lagoons were observed with the Interior dike walls sloughing off due to wave action and now they have vertical 1:1 slope. • Remedial actions should have already been taken to correct this problem and prevent further occurrences in the future. The Division of Water Resources may pursue enforcement action for this and any additional violations of State law. To prevent further action, please respond in writing to this office within 30 days upon your receipt of this Notice of Violation regarding your plans or measures to be taken to address the indicated violations and other identified issues, if applicable. Mare Cnei a Oer.tnmt al C.Wamatim•+tit I Ohl*. d 11Lfc hft�tn Wpshapon PglOei Office I '43 WashilomS0x.,Ilan I W.11.7bnl4e UuYotMM If you should have any questions, please do not hesitate to contact Sarah Toppen with the Water Quality Regional Operations Section in the Washington Regional Office at 252-946-6481. Sincerely, Ris T444441 Robert Tankard, Assistant Regional Supervisor Water Quality Regional Operations Section Washington Regional Office Division of Water Resources, NCDEQ ATTACHMENTS Cc: Laserfiche Eric Harper, ORC (ericbayriver@gmail.com) ..-.11.-f,s93 `b.th CapYV O!pxn.c.w at Cr. vanrrtd Q.Jtt I D.1Ju. ct Waa Cew[r+ WaYinyo.+ p+v.°d Office wn YY,WwgEm spurt 1A1 15YrJ6gIan Atrth C..v1iu LT ' hl W..WI Compliance Inspection Report Permit: WO0013348 Effective: 05/21/19 Expiration: 08/31/24 Owner : Bay River Metropolitan Sewer District SOC: Effective: Expiration: Facility: Pamlico Regional WWTFs County: Pamlico 1448 Hwy 304 Region: Washington Contact Person: Eric Harper Directions to Facility: System Classifications: Si, Primary ORC: Davld Eric Harper Secondary ORC(s): On -Site Representative(s): Related Permits: Inspection Date: 09/19/2022 Primary Inspector: Sarah A Toppen Secondary Inspector(s): Bayboro NC 28515 Title: Phone: 252-745-4812 Certification: 986019 Phone: 252-745-4812 Entry Tlme 10:30AM Exit Time: 11:45AM Phone: 252-946-6481 Reason for Inspection: Routine Inspection Type: Compliance Evaluation Permit Inspection Type: Wastewater Irrigation Facility Status: ❑ Compliant I Not Compliant Question Areas: Miscellaneous Questions Treatment Lagoons (See attachment summary) Page 1 of 3 Permit: WQ0013348 Owner - Fealty:Bay River Metropolitan Sewer District Inspection Date: 09/19/2022 Inspection Type : Compliance Evaluation Reason for Visit Routine Inspection Summary: On Monday, September 19, 2022, Sarah Toppen and Robert Tankard with NCDWR met Eric Harper at the Oriental wastewater lagoon. The three Oriental facultative lagoons were observed with the Interior dike walls sloughing off due to wave action and now they have vertical 1:1 slope. A 2:1 slope is recommended so that a failure/breach can be prevented and keep the structural integrity that is required at the lagoons, refer to 15A NCAC 02T .0108(b)(1)(A). The interior walls separating the cells had sloughed and appeared to be at a lower elevation than the perimeter dike walls. The operator no longer felt safe mowing on top of the bank in these locations. The facility is not in compliance with the permit and a Notice of Violation has been Issued Refer to NOV-2022-PC-0531 for more Information. Page 2 of 3 permit: WQ0013348 Owner - Facility: Bay River Metropolitan Sewer District Inspection Date: 09/19/2022 Inspection Type :Compliance Evaluation Reason for Visit: Routine I Single Family Spray, LR Lagoon Spray, LR Infiltration System Reuse (Quality) Activated Sludge Spray, LR Activated Sludge Spray, HR Activated Sludge Drip, LR Recycle/Reuse Single Family Drip Yes No NA NE Page 3 of 3