HomeMy WebLinkAbout20141058 Ver 1_Email_20141007
Ridings, Rob
From:Ridings, Rob
Sent:Tuesday, October 07, 2014 1:31 PM
To:Murray, Christopher A; Alsmeyer, Eric C SAW
Cc:Briley, William R; Burton, Bradley D; Pearson, Donald R
Subject:RE: Repair of damaged pipe structure on SR 1102 (Sedwick Road) conveying an Unnamed
Tributary to Northeast Creek in Durham County
Chris,
Thanks for the notification. I agree the work can proceed under GC’s 3885 and 3883, with Jordan Buffer approval as
exempt.
Rob Ridings
Transportation Permiting Unit,
Division of Water Resources, Wetlands Branch
rob.ridings@ncdenr.gov
Phone: 919-707-8786
From: Murray, Christopher A
Sent: Friday, October 03, 2014 5:27 PM
To: Alsmeyer, Eric C SAW; Ridings, Rob
Cc: Briley, William R; Burton, Bradley D; Pearson, Donald R
Subject: Repair of damaged pipe structure on SR 1102 (Sedwick Road) conveying an Unnamed Tributary to Northeast
Creek in Durham County
Rob and Eric-
o
Durham County Bridge Maintenance has a cross line in need of replacement on SR 1102 (Sedwick Road) at 35.88242N,
o
78.91273W. The structure conveys an Unnamed Tributary to Northeast Creek (DWQ Index Number: 16-41-1-17-(0.7);
Water Classification: WS-IV NSW) in the Jordan Watershed of the Cape Fear River Basin. The existing pipe structure is a
72 inch metal pipe that is 70 feet long. The pipe has failed and will be replaced with a 12 ft 3 in x 7 ft 3 in aluminum structural
plate pipe arch that is 68 feet long.
Installation of the pipe structure and will result in impacts to the stream and regulated riparian buffer. The Department expects
the following impacts:
Permanent stream loss (rip rap on banks): 25 linear feet
Temporary stream impact (dewatering): 100 linear feet (with 25 linear feet that is concurrent with rip rap on banks)
Jordan Watershed of the Cape Fear River Riparian Buffer impacts: 40 linear feet of impact.
This cross line is within the Jordan Watershed of the Cape Fear River riparian buffer, but the minimal activity here is
EXEMPT from buffer rules. Work will be done from the roadway with new disturbance in buffers limited to rip rap
armoring on the stream banks for long term stabilization. No wetlands exists within the construction footprint.
We
under a non-reporting NWP 3 and NWP 13 with corresponding WQC No. 3883 and WQC No. 3885.
propose to work
For maintenance sites such as this one, NCDOT Division 5 has a procedure in place to provide our construction crews
with print outs of the general conditions along with a letter head cover sheet explaining the intent to operate under a
non-reporting permit as long as all applicable conditions are meet. Oversight from both the Environmental Staff and REU
Field Operations Unit will ensure compliance with the permit conditions are met and that standard BMPs are followed.
Work at this site is scheduled to begin on October 6, 2014.
Please advise if you need additional information.
1
Thanks,
Christopher A. Murray, P.W.S.
NCDOT Division 5 Environmental Supervisor
2612 N. Duke Street
Durham, NC 27704
Phone: (919) 220-4633
Email correspondence to and from this sender is subject to the N.C. Public Records Law and may be disclosed to third parties.
2