HomeMy WebLinkAboutWQ0043767_Application (FTSE)_20220914State of North Carolina DWR Department of Environmental Quality Division of Water Resources FAST TRACK SEWER SYSTEM EXTENSION APPLICATION Division of Water Resources FTA 06-21 & SUPPORTING DOCUMENTATION Application Number: WQD45iwmbecompletedbyDwR) All items must be comoleted or the aonlication will be returned L APPLICANT INFORMATION: 1. Applicant's name: Hawthorne -Midway Brightwood Farm. LLC (company, municipality, HOA, utility, etc.) 2. Applicant type: ❑ Individual ❑ Corporation ❑ General Partnership ❑ Privately -Owned Public Utility ❑ Federal ❑ State/County ❑ Municipal ® Other 3. Signature authority's name: Phil Pavonk per 15A NCAC 02T .0106(b) Title: Manager 4. Applicant's mailing address: 806 Green Valley Road, Suite 311 City: Greensboro State: NC Zip: 27408 5. Applicant's contact information: Phone number: (919) 949-8181 Email Address: pmavonk�a,hpliving com H. PROJECT INFORMATION: 1. Project name: Hawthorne at Brightwood Farm 2. Application/Project status: ® Proposed (New Permit) . ❑ Existing Permit/Project If a modification, provide the existing permit number: W000_ and issued date: _, For modifications, also attach a detailed narrative description as described in Item G of the checklist. If new construction, but part of a master plan, provide the existing permit number: W000_ 3. County where project is located: Guilford 4. Approximate Coordinates (Decimal Degrees): Latitude: 36.070984' Longitude:-79.584771 ° 5. Parcel ID (if applicable): 8824751391 or Parcel ID to closest downstream sewer) III. CONSULTANT INFORMATION: I. Professional Engineer: Nolan Franz License Number: 050507 Firm: Hagen Engineering, PA Mailing address: 3859 Battleground Avenue, Suite 300 City: Greensboro State: NC Zip: 27410 Phone number: 3( 36) 286-3350 Email Address: nfranz@hagen-eng.com IV. WASTEWATER TREATMENT FACILITY (W WTF) INFORMATION: 1. Facility Name: TZ Osborne Permit Number: NCO047384 Owner Name: City of Greensboro V. RECEIVING DOWNSTREAM SEWER INFORMATION: 1. PermitNumber(s): W00022153 2. Downstream (Receiving) Sewer Information: 8 inch ® Gravity ❑ Force Main 3. System Wide Collection System Permit Number(s) (if applicable): WQCS_ Owner Name(s): C of Burlington FORM: FTA 06-21 Page I of 5 VI. GENERAL REQUIREMENTS 1. If the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached? [--]Yes [:]No ®N/A 2. If the Applicant is a Developer of lots to be sold, has a Developer's Operational Agreement (FORM: DEV) been attached? ❑ Yes ❑ No ® N/A 3. If the Applicant is a Home/Property Owners' Association, has an HOA/POA Operational Agreement (FORM: HOA) and supplementary documentation as required by 15A NCAC 02T.0115(c) been attached? ❑ Yes ❑ No ® N/A 4. Origin of wastewater: (check all that apply): ❑ Residential (Individually Owned) ❑ Retail (stores, centers, malls) ❑ Car Wash ® Residential (Leased) ❑ Retail with food preparation/service ❑ Hotel and/or Motels ❑ School / preschool / day care ❑ Medical / dental / veterinary facilities ® Swimming Pool/Clubhouse ❑ Food and drink facilities ❑ Church ❑ Swimming Pool/Filter Backwash ❑ Businesses / offices / factories ❑ Nursing Home ❑ Other (Explain in Attachment) 5. Nature of wastewater: LOIZ%Domestic _%Commercial _ %Industrial (See 15A NCAC 02T .0103(20)) If Industrial, is there a Pretreatment Program in effect? ❑ Yes❑ No 6. Hasa flow reduction been approved under 15A NCAC 02T .0114(fl? ❑ Yes ®No ➢ If yes, provide a cony of flow reduction approval letter with this application 7. Summarize wastewater generated by project: Establishment Type (see 02T.0114(t)) Daily Design Flow ",b No. of Units Flow Multifamily Dwelling— I Bedroom 240 gal/day 30 7200 GPD Multifamily Dwelling — 2 Bedroom 240 gal/day 36 8640 GPD Multifamily Dwelling — 3 Bedroom 360 gal/day 6 2160 GPD 0 GPD 0 GPD GPD Total 1 18000 GPD a See 15A NCAC 02T .0114(b), (d), (e)(1) and (e)(2) for caveats to wastewater design flow rates (i.e., minimum flow per dwelling; proposed unknown non-residential development uses; public access facilities located near high public use areas; and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in G.S. 42A-4). b Per 15A NCAC 02T .01 L 4(c), design flow rates for establishments not identified [in table 15A NCAC 02T.01141 shall be determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data. 8. Wastewater generated by project: 18000 GPD (per 15A NCAC 02T .0114) ➢ Do not include future flows or previously permitted allocations If permitted flow is zero, please indicate why: ❑ Pump Station/Force Main or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line. Please provide supplementary information indicating the approximate timefmme for permitting upstream sewers with flow. ❑ Flow has already been allocated in Permit Number: Issuance Date: ❑ Rehabilitation or replacement of existing sewers with no new flow expected ❑ Other (Explain): _ FORM: FTA 06-21 Page 2 of 5 VII. GRAVITY SEWER DESIGN CRITERIA (If Applicable) - 02T .0305 & MDC (Gravity Sewers): 1. Summarize gravity sewer to be permitted: Size (inches) Length (feet) Material 8" 534' PVC ➢ Section II & III of the MDC for Permitting of Gravity Sewers contains information related to design criteria ➢ Section III contains information related to minimum slopes for gravity sewer(s) ➢ Oversizing lines to meet minimum slope requirements is not allowed and a violation of the MDC VIII. PUMP STATION DESIGN CRITERIA (If Applicable) — 02T .0305 & MDC (Pump Stations/Force Mains): PROVIDE A SEPARATE COPY OF THIS PAGE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT 1. Pump station number or name: 2. Approximate Coordinates (Decimal Degrees): Latitude: Longitude: 3. Total number of pumps at the pump station: 3. Design flow of the pump station: _ millions gallons per day (firm capacity) ➢ This should reflect the total GPM for the pump station with the largest pump out of service. 4. Operational point(s) per pump(s): _ gallons per minute (GPM) at _ feet total dynamic head (TDH) 5. Summarize the force main to be permitted (for this Pump Station): Size (inches) Length (feet) Material If any portion of the force main is less than 4-inches in diameter, please identify the method of solids reduction per MDCPSFM Section 2.01C.1.b. ❑ Grinder Pump ❑ Mechanical Bar Screen ❑ Other (please specify) _ 6. Power reliability in accordance with 15A NCAC 02T .0305(h)(1): ❑ Standby power source or ❑ Standby pump ➢ Must have automatic activation and telemetry - 15A NCAC 02T.0305(h)(1)(B): ➢ Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day ➢ Must be permanent to facility and may not be portable Or if the pump station has an average daily flow less than 15,000 gallons per day I SA NCACO2T.0305(h)(1)(C): ❑ Portable power source with manual activation, quick -connection receptacle and telemetry - or ❑ Portable pumping unit with plugged emergency pump connection and telemetry: ➢ Include documentation that the portable source is owned or contracted by the applicant and is compatible with the station. ➢ If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided as part of this permit application in the case of a multiple station power outage. FORM: FTA 06-21 Page 3 of 5 M. SETBACKS & SEPARATIONS — (02B .0200 & 15A NCAC 02T.0305(f)): 1. Does the project comply with all separations/alternatives found in 15A NCAC 02T.0305(f) & (a)? ® Yes ❑ No 15A NCAC 02T.0305(f) contains minimum separations that shall be provided for sewer systems: Setback Parameter* Separation Required Storm sewers and other utilities not listed below (vertical) 18 inches 'Water mains (vertical - water over sewer preferred, including in benched trenches) 18 inches 'Water mains (horizontal) 10 feet Reclaimed water lines (vertical - reclaimed over sewer) 18 inches Reclaimed water lines (horizontal - reclaimed over sewer) 2 feet **Any private or public water supply source, including any wells, WS-I waters of Class I or Class 11 impounded reservoirs used as a source of drinking water, and associated wetlands. 100 feet **Waters classified WS (except WS-1 or WS-V), B, SA, ORW, HQW, or SB from normal high water (or tide elevation) and wetlands associated with these waters (see item IX.2) 50 feet **Any other stream, lake, impoundment, or ground water lowering and surface drainage ditches, as well as wetlands associated with these waters or classified as WL. 10 feet Any building foundation (horizontal) 5 feet Any basement (horizontal) 10 feet Top slope of embankment or cuts of 2 feet or more vertical height 10 feet Drainage systems and interceptor drains 5 feet Any swimming pools 10 feet Final earth grade (vertical) 36 inches ➢ If noncompliance with 02T.0305(f) or (g), see Section X.1 of this application *15A NCAC 02T.0305(e) contains alternatives where separations in 02T.0305(t) cannot be achieved. Please check "yes" above if these alternatives are used and provide narrative information to explain. **Stream classifications can be identified using the Division's NC Surface Water Classifications webr aye 2. Does this project comply with the minimum separation requirements for water mains? ® Yes ❑ No ❑ N/A ➢ If no, please refer to 15A NCAC 18C.0906(f) for documentation requirements and submit a separate document, signed/sealed by an NC licensed PE, verifying the criteria outlined in that Rule. 3. Does the project comply with separation requirements for wetlands? ®Yes ❑ No ❑ N/A ➢ Please provide supplementary information identifying the areas of non-conformance. ➢ Seethe Division's draft separation requirements for situations where separation cannot be met. ➢ No variance is required if the alternative design criteria specified is utilized in design and construction. 4. Is the project located in a river basin subject to any State buffer rules? ® Yes Basin name: Cape Fear ❑ No If yes, does the project comply with setbacks found in the river basin rules per 15A NCAC 02B .0200? ® Yes ❑ No ➢ This includes Trout Buffered Streams per I SA NCAC 213.0202 5. Does the project require coverage/authorization under a 404 Nationwide/individual permits ❑ Yes ® No or 401 Water Quality Certifications? ➢ Please provide the permit number/permitting status in the cover letter if coverage/authorization is required. 6. Does project comply with 15A NCAC 02T.0105(c)(6) (additional permits/certifications)? ❑ Yes ® No Per 15A NCAC 02T.0105(c)(6), directly related environmental permits or certification applications must be being prepared, have been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent permits (erosion and sedimentation control plans, stormwater management plans, etc.). 7. Does this project include any sewer collection lines that are deemed "high -priority?" []Yes ® No Per 15A NCAC 02T.0402, "high -priority sewer" means any aerial sewer, sewer contacting surface waters, siphon, or sewers positioned parallel to streambanks that are subject to erosion that undermines or deteriorates the sewer. Siphons and sewers suspended through interference/conflict boxes require a variance approval. ➢ If yes, include an attachment with details for each line, including type (aerial line, size, material, and location). High priority lines shall be inspected by the permittee or its representative at least once every six -months and inspections documented per 15A NCAC 02T.0403(a)(5) or the permittee's individual System -Wide Collection permit. FORM: FTA 06-21 Page 4 of 5 X. CERTIFICATIONS: 1. Does the submitted system comply with 15A NCAC 02T, the Minimum Design Criteria for the Permitting of Pump Stations and Force Mains (latest version), and the Gravity Sewer Minimum Design Criteria (latest version) as applicable? ® Yes ❑ No If no, for projects requiring a single variance, complete and submit the Variance/Alternative Design Request application (VADC 10-14) and supporting documents for review to the Central Office. Approval of the request will be issued concurrently with the approval of the permit, and projects requiring a variance anoroval may be subject to longer review times. For projects requiring two or more variances or where the variance is determined by the Division to be a significant portion of the project, the full technical review is reouired. 2. Professional Engineer's Certification: I, F(0.J1 :� , attest that this application for Hawthorne at Brightwood Farm (Professional Engineer's name from Application Item III.1.) (Project Name from Application Item II.1) has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans, specifications, engineering calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Minimum Design Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains (latest version). Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. NOTE — In accordance with General Statutes 143-215.6A and 143-215.613, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000, as well as civil penalties up to $25,000 per violation. Misrepresentation of the application information, including failure to disclose any design non-compliance with the applicable Rules and design criteria, may subject the North Carolina -licensed Professional Engineer to referral to the licensing board. (21 NCAC 56.0701) North Carolina Professional Engineer's seal, signature, and date: I no-L 3. Applicant's Certification per 15A NCAC 02T .0106(b): I, ph " 1 P 6- V Ur k , attest that this application for H el 414hyQ7 C C4 Brr A/ Lewd (Signature Authority Name from Application Item I.3.) (Project Name from Application Item I1.1) FG✓ rt attest that this application has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. I understand that any discharge of wastewater from this non -discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties, injunctive relief, and/or criminal prosecution. I will make no claim against the Division of Water Resources should a condition of this permit be violated. I also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. NOTE — In accordance with General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. Signature: V & ` k Date: 6-9-2022 FORM: FTA 06-21 Page 5 of 5 u�M u.s. oePnarwexrov ixeosreuoa s. esawceu. suxrEr .:`s rGpo 7/22/22, 4:41 PM GIS Data Viewer Parcel Number 106269 Total Out Building Value 0 PIN 8824751391 Total Land Value 1064500 Owner HAWTHORNE-MIDWAY BRIGHTWOOD FARM LLC ! Total Deferred Value 0 Owner History Card Image .. ''. Bldg Card . Mad Address 806 GREEN VALLEY RD STE 311 Appraisal Model Code Mail City GREENSBORO !.. Deed Data 12/28/2021 Mail State NC '.. Neighborhood 8824A02 Mail Zip 27408 ! Property Type RESIDENTIAL Property Address 613 BRIGHTWOOD FARM PKWY Structure Size Legal Description BRIGHTWOOD FARM PL208-34- Lot Size 21.29 Deed-008560-01603 Year Built Plat. 208-34 !Bedrooms....... _. Condo :. Bathrooms Total Assessed 1064500 Grade Total Building Value 0 _.. ..... _. Disclaimer.. While every effort is made to keep information provided over the internet accurate and up-to-date, Guilford County does not certify the authenticity or accuracy of such information. No warranties, express or implied, are provided for the records and/or mapping data herein, or for their use or interpretation by the User. Map Scale 1 Inch = 500 feet 7/22/2022 https:l/gisdv,gulifordcountync.gov/guiifbrdt 1/1 State of North Carolina t.. F a r Sri i Department of Environment and Natural Resources TO & Division of Water Resources UR4latnn eef 1Ndle•t'Rr>,ouracs Flow Tracking/Acceptance for Sewer Extension Permit Applications (FTSE 10-18) Enity Requesting Allocation City of Burlington Project Name for which flow is being requested: Hawthorne @ Brightwood Farm - Private More than one MA-10107 may be required for a single project ifthe owner of the WWTP is not responsible for al/pump stations along the route of the proposed wastewater flow. Complete this section only if you are the owner of the wastewater treatment plant. a. WWTP Facility Name: City of Burlington Collection System b. WWTP Facility Permit #: WOCS00008 All flows are in GPD c. WWTP facility's permitted flow Allocation from Greensboro 900,000 d. Estimated obligated flow not yet tributary to the WWTP 164,688 e. WWTP facility's actual avg. flow 341,622 f. Total flow for this specific request 54,000 g. Total actual and obligated flows to the facility 560,310 h. Percent of permitted flow used 62.3% 1I. Complete this section for each pump station you are responsible for along the route of this List pump stations located between the project connection point and the WWTP : None (A) (B) (C) (D)=(B+C) Obligated, Total Design Approx. Not Yet Current Flow Firm Average Daily Current Avg. Tributary Plus Pump Station Capacity, ` Flow" Daily Flow, Daily Flow, Obligated Name GPD (Firm/pf1, GPD GPD GPD Flow None (E)=(A-D) Available Capacity... " The Firm Capacity of any pump station fa deflned as the maximum pumped flow that can be achieved with the largest pump taken out of service. . "• Design Average Daily Flow Is the firm capacity of the pumpstation divided by a peaking factor (pf) not lase than 2.5. "* A Planning Assessment Addendum shall be attached for each pump station located between the project connection point and the WWTP where the Available Capacity s 0. Downstream Facility Name (Sewer) : Brightwood Farms Phase4, Section I Downstream Permit Number: WQ0030417 Page 1 of 2 FTSE 10-18 Certification Statement: I, W. Todd Lambert, P.E. certify to the best of my knowledge that the addition of the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances, given the implementation of the planned improvements identified in the planning asssessment where applicable. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items listed above in Sections I and II plus all attached planning assessment addendums for which I am the responsible party. Signature of this form certifies that the receiving collection system or treatment works has adequate capacity to transport and treat the proposed new Signing Offlclal Signature City Engineer Title of Signing Official '7i7,/ Date Page 2 of 2 FTSE 10-18 State of North Carolina Department of Environmental Quality Division of Water Resources Olvlslon of Water Resources Flow Tracking for Sewer Extension Applications (FTSE 10-18) Entity Requesting Allocation: City of Burlington Project Name for which flow is being requested: Hawthorne 6c7 Brightwood Farm - Private_ More than one FTSE may be required for a single project tithe owner of the WWTP is not responsiblefor all pump stations along the route of the proposed wastewater flow I. Complete this section only if you are the owner of the wastewater treatment plant. a. WWTP Facility Name: T.Z. Osborne b. WWTP Facility Permit #: NCO047384 All flows are in MGD c. WWTP facility's permitted flow 56.0 d. Estimated obligated flow not yet tributary to the WWTP 0.7237 e. WWTP facility's actual avg. flow 34.7800 f. Total flow for this specific request 0.0180 g. Total actual and obligated flows to the facility 36.9237 h. Percent of permitted flow used 65.9% 11. Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow. List pump stations located between the project connection point and the WWTP: (A) Design Pump Pump Average Station Station Firm Daily Flow** (Name or Permit Capacity, * (Firm / pf), Number) No. MGD MGD Rock 37034 4.32 2.057 (R) (C) (D)=(B+C) (D')=(A-D) Obligated, Approx. Not Yet Total Current Current Tributary Flow Plus Avg. Daily Daily Flow, Obligated Available Flow, MGD MOD Flow Capacity*** 1.257 0.4108 1.6679 0.3892 Stewart, 38555 10.224 4.963 1.796 0.2924 2.0885 2.8746 A' 1 * The Firm Capacity (design flow) of any pump station is defined as the maximum pumped flow that can be achieved with the largest pump taken out of service. ** Design Average Daily Flow is the firm capacity of the pump station divided by a peaking factor (pl) not less than 2.5, per Section 2.02(A)(4)(c) of the Minimum Design Criteria. *** A Planning Assessment Addendum shall be attached for each pump station located between the project connection point and the WWTP where the Available Capacity is < 0. Downstream Facility Name (Sewer): City of Greensboro T.Z. Osborne Downstream Permit Number: NCO047384 Page 1 of 6 FTSE 1()-18 III. Certification Statement: I Wendy Messer certify to the best of my knowledge that the addition of the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances, given the implementation of the planned improvements identified in the planning assessment where applicable. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items listed above in Sections I and II plus all attached planning assessment addendums for which I am the responsible party. Signature of this form certifies that the receiving collection system or treatment works has adequate capacity to transport and treat the proposed new wastewater. Date D�anany eianea nywaaav Maser DN G(IB Wendy MesserGCryMGreenabwo CN We ay Mmee a'a04 Dab. 204.09.1314:05I 00 Page 2 of 6 FTSE 10-18 HAGEN 3859 Battleground Ave, Suite 300 ENGINEERING, PA Greensboro, NC 27410 Winston-Salem Regional Office Water Quality Section 450 W. Hanes Mill Road Suite 300 Winston-Salem, North Carolina 27105 (336)776-9800 RE: Hawthorne at Brightwood Farm Private Sewer Permit Cover Letter t NC DepartmentnP Envircnrncrital (-,ualwv Received �FP 14 2G22 1 Winston-Salem Regional Office Phofie:(336)286-3350 www.hagen-eng.com September 2, 2022 The purpose of this cover letter is to outline the contents of this Private Sewer Permit application package as well as to provide of a summary of the project to which is pertains. The overall Hawthorne at Brightwood Farm development is a 312 unit multifamily complex. This Private Sewer permit will require an estimated peak flow of 18000 GPD for utility consumption, due to a majority of the peak flow for the project being allocated for the Public Sewer permit being applied for the same project. This portion of the project will be comprised of 534 LF of 8" PVC private gravity sewer main. Within this submittal package you will find the following items: 1) $480 check for the Private Sewer Permit 2) One completed DWR Fast Track Sewer System Extension application 3) One executed FTSE 04-16 4) One 8.5" x 11" USGS Topo Map 5) One street level map (aerial) 6) One copy of application and supporting documents Thank you, K. Bryce Morrison Hagen Engineering, PA 336-286-3350