Loading...
HomeMy WebLinkAboutSW3220901_Plansheet - SCM Detail_2022091411 f-\ i ��0 1 _ I g 98 B"AINTENANC \ " t AND/ACCESS /\ EAS ENT A\PEPJIN DE �P'�1E�JT'�,C� L'LC"E LITTORAL SHELFW/ " ` % � \" 'ARCC E C 61 #� 1 1 c E \ \ \ SLOPES TO BE SEEDED WITH TALL FESCUE WETLAND PLANTINGS ` I B 32 8 G �2� 1 \ \ 3 ?0 PER EROSION CONTROL PLANS OUTLET STRUCTURE WITH 6' MIN. WIDTH ` 32.132, A �E E D " \ MAINTENANCE ACCESS 300 YEAR EVENT RIPRAP BERM AND WEIR TRASH RACK 1' MIN. MAINTENANCE ACCESS .451 AC+ " C E E ( �G /� 30 MIN. STORMWATER STORAGE CLASS B RIPRAP WATER QUALITY ORIFICE FREEBOARD 0' MIN WAX H W OCII G: ELEV. 637.54 15 MIN. DEPTH LOCATED THIS SIDE SEE DETAIL k 1 P ELEV. 639.00 - TOP ELEV. 635.00 -ELEV. 639.00 -...- ... - ... �... ... - ... -... ... -... - - - - - EMERGENCY WEIR -..-...-...-. -...-...-...-...-...-...-.. \20'EMERGEIiICYSPILLW Y RI1�RP► TPo�...-...-...-=..-...-...-...-...-... ...-...-...-..50YR-,HWEL637.30 ... ... ... -... -... ELEV.637.50 a 'APRON � � 25 YR - HW EL 637.03 .-...-...-...-...-...-... ...-... -... �4 \LE/.637.50-TEIVIPORAliYY00t- PERMANEN�OL D FES ' ` 10 YR - HW EL 636.54 ` HEADWALL OR FES E[E1r63"' � INV=633.50-...-... ...-...-...--..-...-... ... ,-S, °°°- 1 MIN. 2YR HW EL635.50 12 DPE - x „Ill Rio io:is�o ..,. tj aj \ \ STORM INLET ENERGY DISSIPATER 10' LITTORAL SHELF 10 �19P OF SEA ti' INV = 626.13 117 LF-36 RCP @ 1.11 xV �-��� / III ELEV. 639• 00 / STABILIZED TO POND _I BOTTOM IN POND SEDIMENT FOREBAY SEDIMENT STORAGE TOP ELEV = 6 8.00 �` '� f � "•� •� "'"• hANTI-SEEP COLLARS --638 - f " " SEDIMENT STORAGE TOP ELEV = 629.00 s \ - BOTTOM ELEV. 627.50 • MATERIAL: CLASS B CONCRETE v...... =6 / / BOTTOM ELEV = 628.50 ANTI -FLOATATION PAD • HEIGHT: COLLAR MUST EXTENDED 18" ABOVE THE TOP OF PIPE AND 12" BELOW 35 77THE BOTTOM OF THE PIPE TRENCH ©: ���� ���� ��� �` POND CROSS SECTION " f �` pER • WIDTH: COLLAR MUST EXTENDED 6 633.5 BEYOND TRENCH SIDEWALLS W W W W Ej• W W W / NOT TO SCALE wow ��� � � � � � �� •„�-� / • THICKNESS: 12" W w w W W 633 632 631 w �6&S " 63 64 W W TRASH RACK SEE DETAIL THIS SHEET 645 bta AN175EEPOLLARS VALVE STEM EXTENSION ° .. .0 .. 12" BELOW GRATE OUTLET CONTRO)_C STR 1RE W W w E w• j " % ..,.. 625 • I TOP OF STRUCTURE f SEE'DETAIILTHI=SIHH E I.r W (/ HDPH` ELEV. 636.50 ° W W W � 4, WSW'.- ° STEPS PER NCDOT STD. 840.66 w gl l_ PERMANENT POOL LEVEL TO BE ° 2' I x 11 f PERMANENTLY MARKED ON FRONT 2' RECTANGULAR WEIR y OF CONTROL STRUCTURE WITH 2.5" WATER QUALITY ORIFICE ELEV: 635.00 STAFF GAUGE OR SIMILAR DEVICE BLEEDER W ) 11 j m e I INV, 633.50 ° 'S� 1 1 l WW W /� / f/ l 4" PERMANENT POOL ELEV. 633.50 INV = 633.50 w w 2 "'° l W w 11 11 1 1# l 1 1 = 2.5" WATER QUALITY W W c GROUND AT FRONT OF STRUCTURE M _ r, .° / a ELEV. 632.00 ORIFICE BLEEDER a 2' RECTANGULAR WEIR ^ "o / / I I ( 1 ELEV. 635.00 4Oco �M vim• ••..0 .. / / / / J f PRECAST CONCRETE STRUCTURE 2:1 SLOPE i INSIDE DIMENSIONS SIX 5' (NCDOT STD 840.45) W .. „� "�• W w w �•W � � °� 6" WALL THICKNESS W LF - - / / MAA IN x / /UREITOHEIIRS 36" RCP W OTTQNhP6°ND ELEV-= U730- W / / / I / OARCEL 614 3 INV: 626.13 ° SEDIMENT STORAG�T6P/Et�V = 628.00 ( (l P N DE�b AVA BLE 4" DIP DRAIN E UNIOJ CO TYZONING: 20 MIN.IFTCLEARANCE V � � � � � �} � �• , W W �� �" � j 1� � $,�•° TO STRUCTURE WALL PLANT SCHEDULE I BMP-WET POND VEGETATED SHELF 4,162 SQ. FT. VEGETATED SHELF PLANTS (50 / 200 SQ. FT.) I 1,040 HERBACEOUS PLANTS COMMON NAME BOTANICAL NAME SIZE SPACING CITY. SWAMP MILKWEED Asclepias incarnata PLUGS 24" O.C. 347 QUILL SEDGE Carex tenera PLUGS 24" O.C. 347 WHITE TURTLEHEAD Chelone glabra PLUGS 24" O.C. 346 * EQUIVALENT PLANTS MAY BE USED AS IDENTIFIED IN NCDEQ STORMWATER DESIGN MANUAL C-3 WET POND, TABLE 3: PLANTS FOR SUBMERGED AND PARTIALLY SUBMERGED VEGETATED SHELVES TRASH RACK SEE DETAIL THIS SHEET 4 VALVE STEM EXTENSION WITH SUPPORTS MOUNTED ° TO STRUCTURRE ALL_ ° 4" GATE VALVE 1' 4" DIP 10:1 SLOPE L„ w w m N �•"' W' � �,. W w w w / / / � � STRUCTURE BOTTOM / � � L � Q a 36 RCP W IJ N°/ x E� " p \ INV: 626.13 W WWw � W ° ° �,J P / ANTI- BLOCK °ANTI=FLOTA BLOCK 645 " �� r MIN. DIMENSIONS: MIN. DIMENSIONS: 7PW X 7'L 3'H ° 7PW X 71 X 1'H ° W RIPRAP BERM" Nw w .... w 4" DIP DRAIN TO w s. w� FPOND BOTTOM FRONT VIEW SIDE VIEW OUTLET STRUCTURE OUTLET STRUCTURE x NOT TO SCALE . w w MAINTENANCE SCHEDULE w W v �r :.w P 1. POND WILL BE USED AS A EROSION CONTROL SEDIMENT BASIN DURING THE CONSTRUCTION PHASE OF THE PROJECT. PRIOR TO w v W w w W ACCEPTANCE OF THE WET POND FOR OPERATION THE FOLLOWING ITEMS MUST BE COMPLETED: POND CONSTRUCTION SEQUENCE ..........m 1. POND WILL BE USED AS A EROSION CONTROL SEDIMENT BASIN DURING THE CONSTRUCTION PHASE OF THE A. THE POND MUST BE CLEANED OF ALL SEDIMENTS ACCUMULATED DURING CONSTRUCTION. PROVIDE' StDIME B. THE CONTROL STRUCTURE SHALL BE INSTALLED PER THE DESIGN. PROJECT. PRIOR TO ACCEPTANCE OF THE WET POND FOR OPERATION THE FOLLOWING ITEMS MUST BE fi STAKE IN FOREBAY, E ( " - COMPLETED: w w W� I � � �, �, _ � C. ALL VEGETATIVE PLANTINGS SHALL BE ESTABLISHED. 7 D. THE POND WATER LEVEL SHALL BEAT THE PERMANENT POOL ELEVATION. RIPhAP APRON A. THE POND MUST BE CLEANED OF ALL SEDIMENTS ACCUMULATED DURING CONSTRUCTION. W } - w W w W W B. THE CONTROL STUCTURE SHALL BE INSTALLED PER THE DESIGN. M M ^ 00 O 2. AFTER EVERY SIGNIFICANT RUNOFF PRODUCING RAINFALL EVENT AND AT LEAST MONTHLY: M C. ALL VEGATATIVE PLANTINGS SHALL BE ESTABLISHED. A. INSPECT THE WET DETENTION BASIN SYSTEM FOR SEDIMENT ACCUMULATION EROSION TRASH ACCUMULATION VEGETATED D. THE POND WATER LEVEL SHALL BEAT THE PERMANENT POOL ELEVATION. B2 -FES M W w w <y°�a COVER, AND GENERAL CONDITION. 2. CONTRACTOR SHALL PROVIDE AS BUILT INFORMATION TO THE ENGINEER FOR FORMAL CERTIFICATION OF J J B. CHECK AND CLEAR THE ORIFICE OF ANY OBSTRUCTIONS SUCH THAT THE DRAWDOWN OF THE TEMPORARY POOL OCCURS THE COMPLETION OF THE BMP TO THE DESIGN PARAMETERS. WITHIN 2 TO 5 DAYS AS DESIGNED. �OOEB Y � �0��� O w� Liw m � "� / 1 �, � 2. REPAIR ERODED AREAS IMMEDIATELY. RE -SEED THE EMBANKMENT AS NECESSARY TO MAINTAIN GOOD VEGETATIVE COVER. MOW NI _ BOTTOM POND ELEV 628.50 n, Z � � � � � VEGETATIVE COVER ON EMBANKMENTTO MAINTAIN MAXIMUM HEIGHT OF SIX INCHES, REMOVE TRASH AS NEEDED. BMP PLANTING NOTES W SEDIMENT STORAGE TOP LO W W ELEV = 629.00 m w p / 3. INSPECT AND REPAIR THE COLLECTION SYSTEM (i.e. CATCH BASINS, PIPING, SWALES, RIPRAP, ETC.) QUARTERLY TO MAINTAIN PROPER 1. IF BARE ROOT SPECIMENS ARE NOT TO BE USED WITHIN 4 DAYS, THEY SHOULD BE PLANTED IN SUITABLE LU RIPRAP a w w w p _ + �" FUNCTIONING. BEDS WITH THE ASSUMPTION THAT IT WILL BE A WHILE BEFORE THEY CAN BE USED. AND THEY SHOULD BE I l,, PROVIDED WITH CONDITIONS MAKING IT POSSIBLE FOR THEM TO SURVIVE AND GROW AS OPTIMALLY AS E APRON / B ICE J 4. REMOVE WOODY VEGETATION NOT PART OF THE APPROVED PLAN ALONG THE DAM EMBANKMENT. POSSIBLE. MELIIDA D RRIS C} E 5. REMOVE INVASIVE AND DEAD VEGETATION IN THE LITORAL SHELF AND REPLANT AS NECESSARY. 2. CONTAINER PLANTS WILL NEED TO BE WATERED REGULARLY (SEVERAL TIMES DAILY WHEN WEATHER IS / /# PARC L �06f41014/ HOT). W w " 1 DB 500, 'IG 344 6. REMOVE ACCUMULATED SEDIMENT FROM THE WET DETENTION BASIN SYSTEM SEMI ANNUALLY OR WHEN THE DEPTH IS REDUCED TO 75% OF THE ORIGINAL DESIGN DEPTH. REMOVED SEDIMENT SHALL BE DISPOSED OF IN AN APPROPRIATE MANNER AND SHALL BE HANDLED IN A 3. PIN ALL SUBMERGED/FLOATING PLANT MATERIAL SECURELY TO THE BOTTOM OF THE POND WITH 12" BENT U11N CQU NTY ON NG R-20 MANNER THAT WILL NOT ADVERSELY IMPACT WATER QUALITY (I.E. STOCKPILING NEAR A WET DETENTION BASIN OR STREAM, ETC.). WIRE PINS. I I 7. PERFORM ANNUAL INSPECTION OF THE POND (ANNUAL INSPECTION REPORTS TO BE KEPT BY THE OWNER). PRIOR TO INSPECTION 4. CUTBACK TALL AND EASILY BROKEN LEAVES AND STEMS AT THE TIME OF TRANSPLANTING. NOTIFICATION MUST BE GIVEN TO STORM WATER SERVICES. 5. NEWLY RECEIVED NURSERY STOCK AND DISTURBED TRANSPLANTS SHOULD NOT BE EXPOSED TO DIRECT SUN t� I I � I x 97 10' SDWK $r 15' G_ ,. EL UTIL ESMT. DRIVE BMP o. WITH -c a ° a N\ 146-CB as I� a a � i -%� GHT ROAD 57, PUBLIC/W -TOWN OF WAXHAW LO IN, ..,... I 1 8. A DAM SAFETY EXPERT SHALL BE CONTRACTED TO MAKE INSPECTIONS OF THE DAM. ANY MORE THAN NECESSARY UNTIL THEY ARE PLACED IN THEIR PERMANENT POSITIONS. GRAPHIC SCALE f 9. MAINTENANCE SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR FOR ONE (1) CALENDAR YEAR FOLLOWING THE CERTIFICATION OF 6. INSERT DRY FERTILIZER TABLETS OR SPIKES NEAR THE PLANTS AT THE TIME OF TRANSPLANTING. j 20 0 10 20 40 COMPLETION, AND THEREAFTER SHALL BE THE RESPONSIBILITY OF THE SUBDIVISION HOMEOWNER'S ASSOCIATION. RIP J ,� # 7. FENCE ENTIRE PLANTING AREA WITH 36" TALL PLASTIC FENCE WITH 1.5"12" OPENINGS. PLASTIC SHALL BE UV STABLE. COLOR SHALL BE BLACK. INSTALL WITH STEEL POST SPACED AT 10' O.C. MAX. PIN THE BOTTOM ! AP N �� LAYER OF THE FABRIC TO THE GROUND WITH 10-12" PINS. FENCING TO REMAIN IN PLACE FOR A PERIOD OF l 1f� ( IN FEET) THE ONE YEAR POST INSTALLATION OF PLANT MATERIAL. x C4- S f 1 inch = 20 ft. 8. STAKE 9" AND 18" PLANTING ZONES PRIOR TO INSTALLATION AND VERIFY AREAS ON PLAN. 24" 36" RCP - 9. PLANTS ARE TO BE INSTALLED IN A RANDOM ARRANGEMENT WITHIN THEIR RESPECTIVE ZONES. INDIVIDUAL p - - SPECIES MAY BE PLANTED TOGETHER IN GROUPS OF 3 TO 5. PLANTS MAY ALSO BE PLANTED INDIVIDUALLY. Uj OiARLES MCCLUf " (3) #4 BARS @ 6" O.C. 10. PLANT QUALITIES ARE TO BE VERIFIED BY CONTRACTOR PRIOR TO INSTALLATION. cp PARCI' ,0614015 W/3" CLR. EA. WAY 11. NO TREES OR WOODY SHRUBS SHALL BE PLANTED ON WET POND EMBANKMENTS. " DEW AVOABLE I rn rn ",No, UN40N COVNTY ZONING: R-70 CONCRETE 12. SEE NCDEQ WETPOND DETAIL FOR PLANTING INFORMATION. COLLAR 33" 33" 2.00' C 66 �" ah TOP OF FOREBAY BERM OUTLET STRUCTURE 2.5" PVC ELEV=633.00 GENERAL NOTES: ELEV = 635.00- CREST OF 10' RIPRAP 1 SPILLWAY ELEV=633.00 1. SEE CONCRETE BARREL AND RISER SPECIFICATIONS (THIS SHEET) ELEV = 633.50- RIPRAP 2. ALL SOIL UNDERLYING AND ADJACENT TO RISER AND FOOTING PERMANENT POOL p 2 TO BE COMPACTED TO 98% MAXIMUM DRY DENSITY AS DETERMINED - BY ASTM D-698 (STANDARD PROCTOR) UNDER THE DIRECTION 9" THICK CLASS TOP OF BERM FOREBAY III III III (� - -III- ( - -III- -III MAIN POND OF THE GEOTECHNICAL ENGINEER. B RIPRAP ELEV =639.00 / �` 2 III -III -III III-III_III-III=11 3. WATERTIGHT RUBBER BOOTS TO MEET THE ASTM C923-84 STANDARD 3 -1 I - -1 I 1-1 1 1-1 1 I-1 SPECIFICATIONS FOR RESILIENT CONNECTORS BETWEEN REINFORCED 2.5 WATER QUALITY ORIFICE EMERGENCY SPILLWAY - - - - - - - - CONCRETE MANHOLE STRUCTURES AND PIPES. CREST ELEV = 637.50 20' ---J/ RIPRAP BERM DETAIL CONCRETE ANTI -SEEP COLLAR DETAIL WATER QUALITY ORIFICE DETAIL EMERGENCY SPILLWAY DETAIL NOT TO SCALE NOT TO SCALE NOT TO SCALE NOT TO SCALE. NOT TO SCALE OPERATION AND MAINTENANCE PROVISIONS FOR WET PONDS (PER NCDEQ STORMWATER MANUAL) SCM ELEMENT POTENTIAL PROBLEMS HOW TO REMEDIATE THE PROBLEM THE ENTIRE SCM TRASH/DEBRIS IS PRESENT. REMOVE THE TRASH/DEBRIS. THE PERIMETER OF AREAS OF BARE SOIL AND/OR EROSIVE REGRADE THE SOIL IF NECESSARY TO REMOVE THE GULLY, THE WET POND GULLIES HAVE FORMED. PLANT GROUND COVER AND WATER UNTIL IT IS ESTABLISHED. PROVIDE LIME AND A ONE-TIME FERTILIZER APPLICATION. THE INLET DEVICE THE INLET DEVICE IS CLOGGED (IF UNCLOG THE PIPE. DISPOSE OF THE SEDIMENT IN A APPLICABLE) LOCATION WHERE IT WILL NOT CAUSE IMPACTS TO STREAMS OR THE SCM. THE INLET PIPE IS CRACKED OR OTHERWISE REPAIR OR REPLACE THE PIPE. DAMAGED (IF APPLICABLE). EROSION IS OCCURRING IN THE SWALE (IF REGRADE THE SWALE IF NECESSARY AND PROVIDE APPLICABLE). EROSION CONTROL DEVICES SUCH AS REINFORCED TURF MATTING OR RIPRAP TO AVOID FUTURE EROSION PROBLEMS. THE FOREBAY SEDIMENT HAS ACCUMULATED TOADEPTH SEARCH FOR THE SOURCE OF THE SEDIMENT AND REMEDY GREATER THAN THE ORIGINAL DESIGN THE PROBLEM IF POSSIBLE. REMOVE THE SEDIMENT AND DEPTH FOR SEDIMENT STORAGE. DISPOSE OF IT IN A LOCATION WHERE IT WILL NOT CAUSE IMPACTS TO STREAMS OR THE SCM. EROSION HAS OCCURRED. PROVIDE ADDITIONAL EROSION PROTECTION SUCH AS REINFORCED TURF MATTING OR RIPRAP IF NEEDED TO PREVENT FUTURE EROSION PROBLEMS. WEEDS ARE PRESENT. REMOVE THE WEEDS, PREFERABLY BY HAND. IF PESTICIDE IS USED, WIPE IT ON THE PLANTS RATHER THAN SPRAYING. THE VEGETATED BEST PROFESSIONAL PRACTICES SHOW PRUNE ACCORDING TO BEST PROFESSIONAL PRACTICES. SHELF THAT PRUNING IS NEEDED TO MAINTAIN OPTIMAL PLANT HEALTH. PLANTS ARE DEAD, DISEASED OR DYING. DETERMINE THE SOURCE OF THE PROBLEM: SOILS, HYDROLOGY, DISEASE, ETC. REMEDY THE PROBLEM AND REPLACE THE PLANTS. PROVIDE AONE-TIME FERTILIZER APPLICATION TO ESTABLISH THE GROUND COVER IF A SOIL TEST INDICATES IT IS NECESSARY. WEEDS ARE PRESENT. REMOVE THE WEEDS, PREFERABLY BY HAND. IF PESTICIDE IS USED, WIPE IT ON THE PLANTS RATHER THAN SPRAYING. THE MAIN SEDIMENT HAS ACCUMULATED TOADEPTH SEARCH FOR THE SOURCE OF THE SEDIMENTAND REMEDY TREATMENTAREA GREATER THAN THE ORIGINAL DESIGN THE PROBLEM IF POSSIBLE, REMOVE THE SEDIMENT AND SEDIMENT STORAGE DEPTH. DISPOSE OF IT IN A LOCATION WHERE IT WILL NOT CAUSE IMPACTS TO STREAMS OR THE SCM. ALGAL GROWTH COVERS OVER 50%OF THE CONSULT A PROFESSIONAL TO REMOVE AND CONTROL THE AREA. ALGAL GROWTH. CATTAILS, PHRAGMITES OR OTHER REMOVE THE PLANTS BY WIPING THEM WITH PESTICIDE INVASIVE PLANTS COVER 50%OF THE (DO NOT SPRAY). BASIN SURFACE. THE EMBANKMENT SHRUBS HAVESTARTEDTOGROWONTHE REMOVE SHRUBS IMMEDIATELY. EMBANKMENT EVIDENCE OF MUSKRAT OR BEAVER CONSULT PROFESSIONALTO REMOVE MUSKRATS OR ACTIVITY IS PRESENT. BEAVERS AND REPAIR ANY HOLES OR EROSION. A TREE HAS STARTED TO GROW ON THE CONSULT A DAM SAFETY SPECIALIST TO REMOVE THE TREE. EMBANKMENT. AN ANNUAL INSPECTION BY AN MAKE ALL NEEDED REPAIRS IMMEDIATELY. APPROPRIATE PROFESSIONAL SHOWS THAT THE EMBANKMENT NEEDS REPAIR. THE OUTLET DEVICE CLOGGING HAS OCCURRED. CLEAN OUT THE DEVICE AND DISPOSE OF ANY SEDIMENT IN A LOCATION WHERE IT WILL NOT CAUSE IMPACTS TO STREAMS OR THE SCM. THE OUTLET DEVICE IS DAMAGED REPAIR OR REPLACE THE OUTLET DEVICE. FLOATING WETLAND WEEDS OR VOLUNTEER TREES ARE REMOVE THE WEEDS OR TREES. ISLAND (IF GROWING ON THE MAT. APPLICABLE) THE ANCHOR CABLE IS DAMAGED, RESTORE THE ANCHOR CABLE TO ITS DESIGN STATE. DISCONNECTED OR MISSING. THE RECEIVING EROSION OR OTHER SIGNS OF DAMAGE REPAIR THE DAMAGE AND IMPROVE THE FLOW WATER HAVE OCCURRED AT THE OUTLET. DISSIPATION STRUCTURE. DISCHARGES FROM THE WET POND ARE CONTACTTHE LOCAL NCDEQ REGIONAL OFFICE. CAUSING EROSION OR SEDIMENTATION IN THE RECEIVING WATER. I � * * * 3 Days Before Digging North Carolina 811 811 or1-800-632-4949 Remote Ticket Entry http://nc811.org/remoteticketentry.htm STIPULATION FOR REUSE THIS DRAWING WAS PREPARED FOR USE ON A SPECIFIC SITE, BLYTHE MILL ROAD, NC CONTEMPORANEOUSLY WITH ITS ISSUE DATE ON 05/10/22. AND IT IS NOT SUITABLE FOR USE ON A DIFFERENT PROJECT SITE OR AT A LATER TIME. USE OF THIS DRAWING FOR REFERENCE OR EXAMPLE ON ANOTHER PROJECT REQUIRES THE SERVICES OF PROPERLY LICENSED ARCHITECTS AND ENGINEERS. REPRODUCTION OF THIS DRAWING FOR REUSE ON ANOTHER PROJECT IS NOT AUTHORIZED AND MAY BE CONTRARY TO THE LAW. Cn E1 O 0 z O Q Z In E a�rv-1 00 z a w O z E­4 o E-4 1- MODIFICATION LOG JOB NUMBER: C210047 CHECKED BY: BHE DRAWN BY: BHE DATE: 05-10-2022 1,99£-0 # AdA Z Cp CL - CV N LO Q CU r- (1) M o nL' W O ~ 0 7 (� LV . - �/Q0 o Cn L t� Q LU CD CV "00 " (1) CV CCU woz �U o a) 00 " CU Eon < 00 0 BMP PLAN SHEET: C595 NOTES: 1� 4-6 |wox LAYER OF AMENDED so/L IS xsroowwswoso ON urmwxL sxsuF AREA wxsns pmwnwoS ARE Rsuu/nso (SEE SOIL p*m*wETEno IN owp oss/ow wAwuA0 o pnov/os no Acosss EAaEwswr TO comwscrWsrpowo cxsswswT TO osmoxrso moHr OF wm'. *cocss ncwo sxAu ���1 suopc HAVE w/m. `z. STABILIZED WIDTH, MAX. uzwu. uxAos OF ���. MAX. onosa-s/ops oz� m RIP RAP INLET PROTECTION OR INLET PIPE powo MmwTswAmos /wrunM*Jmw MUST BE POSTED AT SITE posr oowyrmouno: CONTROLS EASEMENT (PCCE) p ALL BERM SLOPES TO BE STABILIZED WITH GRASS. SLOPE 3:1 SLOPE RISER PERMANENT-PDOL ELEV. ORF'M RACK - PROTECTION JEBpA ARREL 4. 1 SLOPE' MAINTENANCE DRAIN % 20' ACCESS EASEMENT TO PUBLIC PLAN V|�UU / �/-�/ x v / /_ vv EMERGENCY SPILLWAY OUTLET STRUCTURE WITH TRASH HACK. 6" MIN. FREEBOARD FROM TEMP. POOL ELEV. INVERTED WATER QUALITY ORIFICE ` LOCATED THIS SIDE (SEE OETA||) 50 YEAR EVENT STORWWATER STORAGE � 6' MIN. - FREEBOAR� \ TEMPORARY POOL-\ V \ MUST BE LINED AND STABILIZED (10' MINIMUM LENGTH) OPTIONAL: OUTLET STRUCTURE MAY BE DES31GNED AS 50 YEAR OVERFLOW IN LIEU OF EMERGENCY WETLAND PLANTING ow 1» FOOT 10:1 LITTORAL SHELF AROUND pER/wom VU�T[](�N�� PLAN vv�_// ��/v�/ ' NOT TO SCALE 405.1 LITTORAL SHELF WETLAND PLANTINGS, 10' MIN. WIDTH b^ FREEBOARD / EMERGENCY WEIR-�-- |F �"��`USED --_�--- - ---�-- -�---_ PERMANENT PD0 7 _'�7_ ____' _�__- � U MAIN POND 1 COLLARS BACK OF OUTLET STRUCTURE LOCATED AT TOE OF 10:1 SLOPE '(R An 0 ANTI —SEEP ANTI -FLOTATION P- VIDUCTILE IRON MAINTENANCE DRAIN PIPE WITH SLUICE GATE OR VALVE. FFL|NE FROM OUTLET AND LOCATE VALVE |N BERM) O 5y� P[}�[) �F�[}F��� � STRUCTURE VALVE '� ---` - -- SLOPE MIN. PERMANENT POOL � LW/TER QUALITY 0R|F| WATER QUALITY ORIFICE DETAIL TOWN OF WAXHAW VV�T[][\NU vv/_// ��/v// LAND DEVELOPMENT STANDARDS| LITTORAL SHELF AND BERM DETAIL 1/2-X4` YEDGE OR EPDXY ANCHM WITH WING NUT AT SLOTTED CONNECTION L�� r-�"'----' -/ 2-FIAR SUPPORT BARS BENT AT CENTER — WELDED TO PLATE 14 BAR TS TRASH RACK ANGILE, BARS WELDED TO PLATE VIEW TRASH RACK DETAIL NOT TO SCALE. ourLsr STRUCTURE WITH TRASH RACK. h' w|N� FREEBOARD POST CONSTRUCTION FROM TEMP. pDVL CONTROLS EASEMENT RIP RAP BERM s|Ev 10' OFFSET FROM AND WEIR CLASS LITTORAL SHELF W/ SLOPE BREAK B RIP '' INVERTED^PLANTINGSWETLAND - 50 YEAR EVENT w|w. DEPTH. ^'^E'` QUALITY ORIFICE STORMWATER STORAGE - SIDE LOCATED THIS 6^ FREEBOARD R�� F.E.S. OR wpURxRY POO�` \ ''~`~~~`10:1 PERMANENT POOL — SLOP 0 AL SHELF ENERGY DISS 2:1 SLOPE STABILIZED TO POND BOTTOM Wmw POND-' =°,�/ BACK OF OUTLET SEDIMENT F0RE�".-- STRUCTURE LOCATED AT TOE OF 10:1 SLOPE 1. 4-6 |wCn LAYER OF AMENDED SOIL IS RECOMMENDED IN ANY AREA WHERE PLANTINGS ARE REQUIRED (SEE NCDEQ STORMWATER BMP MANUAL). 1. PLANTINGS ZONES AND PLANT SELECTION PER THE NCDB] STORMWATER BMP MANUAL CHAPTER 8 8c APPENDICES. 2. ALL PLANTINGS SHALL BE LOCAL NATIVE SPECIES. 3. IRRIGATION MAY BE PROVIDED FOR INITIAL ESTABLISHMENT AND DRY SEASONS. -FLOTATION PAD VV�T�][�NFl PROFILE vv�_/ / ��/x// ZONE I SEED ZONE 5/6 PLAN VIEW NOT TO SCALE �(~xT1-L-' r hr A � � " It It ` � POND CROSS SECTION NOT TO SCALE VU�T[]/�NFl vv�_// ��/v�� PLANTING N[` PLAN EMERGENCY WEIR IF USED ANxMEmT POST CONSTRUCTION CONTROLS EASEMENT 10' OFFSET FROM ANTI-SEEPSLOPE BREAK OLLARS DUCTILE IRON MAINTENANCE DRAIN PIPE WITH SLUICE GATE OR VALVE. (orruwc FROM OUTLET AND LOCATE VALVE IN BERM) 0.5% SLOPE MIN. NOT TO SCALE 406.1 NO TREES ON EMBANKMENT . , ^ °Ir _v"~ NOT TO SCALE 20' MAINTENANCE ACCESS ACCESS ROAD 1' To z ABOVE *|nn emEn ELEVATION ~ HIGH WAT| �n�w43:1 SrAmuZco S|opc - 1+. r10 FOOT LITTORAL SHELF 2/ FOOT MAINTENANCE ACCESS 15% MAXIMUM LONGITUDINAL SLOPE SECTION AT MAINTENANCE ROAD ACCESS AND FDREBAY 3:1 STABILIZED 20' FOOT MAINTENANCE ACCESS �N�N��ST Li�f �6' MINIMUM FREEBOARD ALONG MAINTENANCE ROAD OUTLET PERMANENT POOL ELEVATI( /U' LITTORAL SHELFJ SECTION AT STORMWATER OUTFALL ' MAINTENANCE ACCESS ROAD 31 2O MAINTENANCE ACCESS ' . ---- SLOPE / To 2 ABOVE H|Qi WATER ELEVATION -----�- STRUCTURE /-3:1 STABILIZED SLOPE/ HIGH WATER ELEVATION MIN. STABILIZED MAINTENANCE ROAD BED 5% MAX. CROSS SLOPE -PERMANENT POOL ELEVATION SECTION AT OUTLET STRUCTURE NOT TO SC/\[[ VV�T[]ONU vv /_ / / �� / v �� CROSS SECTIONS 3 Days Before Digging < North Carolina 811 Remote Ticket Entry STIPULATION FOR REUSE THIS DRAWING WAS PREPARED FOR USE ON A SPECIFIC SITE, BLYTHE MILL ROAD. INC CONTEMPORANEOUSLY WITH ITS ISSUE DATE ON 05/10/22. AND IT IS NOT SUITABLE FOR USE ON A DIFFERENT PROJECT SITE OR AT A LATER TIME. USE OF THIS DRAWING FOR REFERENCE OR EXAMPLE ON ANOTHER PROJECT REQUIRES THE SERVICES OF PROPERLY LICENSED ARCHITECTS AND ENGINEERS. REPRODUCTION OF THIS DRAWING FOR REUSE ON ANOTHER PROJECT IS NOT AUTHORIZED AND MAY BE CONTRARY TO THE LAW. 00 P4 �� � , 1-4 _ ~_ ~+ 1.4 00 � �� | �f� IMODIFICATION LOG JOB NUMBER: C210047 CHECKED BY: BHE DRAWN BY: BHE DATE: 0540'2022 [88C_0#KU8|A ��� ����� ��co � 00 ----' ��� ` Cu I- oor- m_ NmN �- z m 0��� Cn ! CnO �� �� �U � �w �� � � m 0 Z CL Cu � - d BNVIP DETAILS S