HomeMy WebLinkAboutNC0084387_Renewal Application_20140924NCDENR
North Carolina Department of Environment and Natural Resources
Pat McCrory
Governor
Mr. John C. Huber
Charlotte Mecklenburg Utilities
Lee S. Duke WTP
7980 Babe Stillwell Farm Rd.
Huntersville, NC 28078
Dear Mr. Huber:
John E. Skvarla, III
Secretary
September 29, 2014
Subject: Acknowledgement of Permit Renewal
Permit NCO084387
Mecklenburg County
The NPDES Unit received your permit renewal application on September 24, 2014. A member of the
NPDES Unit will review your application. They will contact you if additional information is required to
complete your permit renewal. You should expect to receive a draft permit approximately 30 -45 days
before your existing permit expires.
If you have any additional questions concerning renewal of the subject permit, please contact Derek
Denard (919) 807 -6307.
Sincerely,
W rre w Tkeo -f&roU
Wren Thedford
Wastewater Branch
cc: Central Files
Mooresville Regional Office
NPDES Unit
1617 Mail Service Center, Raleigh, North Carolina 27699 -1617
Location: 512 N. Salisbury St. Raleigh, North Carolina 27604
Phone: 919 -807 -63001 Fax: 919 - 807- 64921Customer Service: 1-877-623-6748
Internet:: www.ncwater.org
An Equal OpportunitylAffirmafive Action Employer
•
CHARIA'I'TEw
September 1, 2014
Division of Water Resources
WQ Permitting Section — NPDES
1617 Mail Service Center
Raleigh NC 27699 -1617
Subject: Renewal NPDES Permit # NCO084387
Lee S. Dukes Water Treatment Plant
Mecklenburg County
WQ Permitting Section,
RECEIVED /DENR/DWR
SEP 2 4 2014
Water Quallty
Permitting Section
In accordance with our permit we are requesting renewal prior to our expiration date of February 28,
2015. Enclosed is our NPDES Permit Applications Short Form C for the renewal of NCO084387 for the
Lee S. Dukes Water Treatment Plant
Also attached to the Short Form C are:
• Response for describing the treatment process for raw water ( #7)
• Response for wastewater and treated process for wastewater generated by the facility ( #8)
• Solids Handling Plan
• Plant Flow Schematic
• Outfall /discharge location
If you have any questions, please contact me at 704 - 399 -2426 extension 222 or Randy Hawkins at 704-
201 -8344.
Sincerely, C
John C. Hu er
Chief of Operations
City of Charlotte
Charlotte - Mecklenburg Utility Department
CHARLOTTE - MECKLENBURG UTILITIES
Water Treatment Division 5200 Brookshire Boulevard
Charlotte, NC 28216
PH: 704/399 -2426
FAX: 704/393 -9163
NPDES PERMIT APPLICATION - SHORT FORM C - WTP
For discharges associated with water treatment plants
Mail the complete application to:
N. C. Department of Environment and Natural Resources RECEIVEDIDENRIDWR
Division of Water Quality / NPDES Unit
1617 Mail Service Center, Raleigh, NC 27699 -1617 S EP 2 4 2014
NPDES Permit Number NCH Water Quality
7 permitting
If you are completing this form in computer use the TAB key or the up - down arrows to move from one
field to the next. To check the boxes, click your mouse on top of the box. Otherwise, please print or type.
1. Contact Information:
Owner Name
Charl ottP MPekl Pnh ura U t i l i t i e s
Facility Name
Lee S Duke WTP
Mailing Address
7980 Babe Stillwell Farm Road
City
Huntersville
State / Zip Code
North Carolina 28078
Telephone Number
( 704 9 4 8 - 6 9 5 4
Fax Number
(704 ) 948 -7581
e -mail Address
dhaniok(doi- charlotte -ne -us
2. Location of facility producing discharge:
Check here if same as above
Street Address or State Road
City
State / Zip Code
County
3. Operator Information:
Name of the firm, consultant or other entity that operates the facility. (Note that this is not referring to the
Operator in Responsible Charge or ORC)
Name City of Charlotte
Mailing Address 5200 Brookshire Blvd
City Charlotte
State / Zip Code N.C. 2 8 21 6
Telephone Number (7 0 4) 399-2426
Fax Number (704) 393-9163
4. Ownership Status:
Federal ❑ State ❑ Private ❑ Public]
Page 1 of 3 Version 5/2012
NPDES PERMIT APPLICATION - SHORT FORM C - WTP
For discharges associated with water treatment plants
S. Type of treatment plant:
Conventional (Includes coagulation, flocculation, and sedimentation, usually followed by
filtration and disinfection)
❑ Ion Exchange (Sodium Cycle Cationic ion exchange)
❑ Green Sand Filter (No sodium recharge)
❑ Membrane Technology (RO, nanofiltration)
Check here if the treatment process also uses a water softener ❑
6. Description of source water(s) (i.e. groundwater, surface water)
7. Describe the treatment process(es) for the raw water:
See Attached
8. Describe the wastewater and the treatment process(es) for wastewater generated by the
facility:
See Attached
9. Number of separate discharge points: 1
Outfall Identification number(s) () () 1
10. Frequency of discharge: Continuous ❑ Intermittent
If intermittent:
Days per week discharge occurs: 7 Duration: Approximately 4hrs /day
11. Plant design potable flowrate2 5 . 31 MGD
Backwash or reject flow .197 MGD
12. Name of receiving stream(s) (Provide a map showing the exact location of each outfall, including
latitude and longitude):
McDowell Creek
13. Please list all water treatment additives, including cleaning chemicals or disinfection
treatments, that have the potential to be discharged.
Alum / aluminum sulfate Ye No
Page 2 of 3 Version 5/2012
NPDES PERMIT APPLICATION - SHORT FORM C - WTP
For discharges associated with water treatment plants
Iron sulfate / ferrous sulfate Yes 6
Fluoride Yes No
Ammonia nitrogen / Chloramines Yes ®o
Zinc - orthophosphate or sweetwater CP1236 Yes
List any other additives below: RECEIVED/DENRIDWR
Chlorine, Carbon, KMN04, Lime, Liquid Linear SEP 2 4 2014
Phosphate, Sodium Bisulfite
Water Quality
vArmlltina Mon
14. Is this facility located on Indian country? (check one)
Yes ❑
No FXI
15. Additional Information:
Provide a schematic of flow through the facility, include flow volumes at all points in
the water treatment process. The plan should show the points] of addition for
chemicals and all discharges routed to an outfall [including stormwater].
Solids Handling Plan
Please see Attached
16. NEW Applicants
Information needed in addition to items 1 -15:
New applicants are highly encouraged to contact a permit coordinator with the
NCDENR Customer Service Center.
Was the Customer Service Center contacted? ❑ Yes ❑ No
Analyses of source water collected
Engineering Alternative Analysis
Discharges from Ion Exchange and Reverse Osmosis plants shall be evaluated using a
water quality model.
17. Applicant Certification
I certify that I am familiar with the information contained in the application and that to the
best of my knowledge and belief such information is true, complete, and accurate.
ohn C. Huber
of Applicant
Chief of Operations
Title
9/1/14
Date
19orth Carolina General Statute 143 -215.6 (b)(2) provides that: Any person who knowingly makes any false statement representation, or certification in any application,
record, report, plan, or other document files or required to be maintained under Article 21 or regulations of the Environmental Management Commission implementing that
Article, or who falsifies, tampers with, or knowingly renders inaccurate any recording or monitoring device or method required to be operated or maintained under Article 21
or regulations of the Environmental Management Commission implementing that Article, shall be guilty of a misdemeanor punishable by a fine not to exceed $25,000, or by
imprisonment not to exceed six months, or by both. (18 U.S.C. Section 1001 provides a punishment by a fine of not more than $25,000 or imprisonment not more than 5
years, or both, for a similar offense.)
Page 3 of 3 Version 5/2012
7. Describe the treatment processes for the raw water.
Raw water is treated with potassium permanganate and carbon as needed. Aluminum sulfate is
added at the head works of the plant. The raw water then passes through three stages of
flocculation before entering the sedimentation basins. Chlorine is added just before filtration.
Raw water is then filtered and lime and chlorine are added. The water is then dosed with
additional chlorine and sent to the clearwells.
8. Describe the wastewater and the treatment processes for wastewater generated by the
facility.
Solids are generated from the water treatment process and consist mostly of alum sludge.
Solids generated from the sedimentation basins are discharged thru a gravity thickener and then
discharged to a holding lagoon. Solids generated from filter backwashes are discharged to an
EQ basin. The solids from the EQ basin are sent to a clarifier. The solids are then sent to the
thickener and then to the holding lagoon. Clarified water goes over the weir of the clarifier,
through a de- chlorination chamber to the NPDES discharge point. Solids from the holding
lagoon are removed and land applied in accordance with our land application permit.
Solids Plan
1. Solids generated from the sedimentation basins are discharged thru a gravity thickener
and then discharged to a holding lagoon.
2. Solids generated from filter backwashes are discharged to an EQ basin. The solids from
the EQ basin are sent to a clarifier. The solids are then sent to the thickener and then to
the holding lagoon. Clarified water goes over the weir of the clarifier, through a de-
chlorination chamber to the NPDES discharge point 001.
3. Solids from the holding lagoon are removed and land applied by a contractor to be land
applied as a liquid. We also have the ability to tanker the liquid to a belt press for
pressing then land applied or taken to a land fill.
4. The contractor must follow the permit # W.Q. 0000057 for solids disposal.
Lake Norman
Lee S. Dukes Water Treatment Plant
Process Flow Diagram as of 28 January 2011
N
M
0
M
v FT-1 C
10 M
a
m
CD
aZF
0 �' 'p
Carbon Alum Chlorine
P KMnOr
ClJodn Chlorin Flouride Lime
Cleanvel
1
9 MG
Sedimentation Filter
East Module 1 East Module 1
_
Finished
Clea wall
Z
High Sery ice
To 978
Walter
pump Station
Zone
WrH/
au
j—low
Sedimentation Filter
/R
z �, 3
d
East Module 2 East Module 2
V
,n g
Clearwell
3
9 MG
r
%�� r uu
Backwash
Waller
Sodium
BisulAle
s I •-
Polymer
Sed Basin
Residuals
Clarifier
EQ
Effluent
DechlorinaUOn
Basin
Clarifier
Contact
To Creek
Chamber
Solids
.�j /�'�
mR�
I,.il
s�
Thickened
Residual.
3, m
Thickener
Lagoon
N
M
0
M
v FT-1 C
10 M
a
m
CD
aZF
0 �' 'p
Qh =s: Fl 5NW
LaawAi -- 35*25 4 y.
Lo4rude: 31*53'1 -1
Scrim Chss: W5-T%; CA
$ubbasin: 30533
Recali-mg Smom: MCDOWd CrCa
NCO084387
CMUD /North
bfcj 6 �s
Facility
Location ,r
No,th SCALE 1:24000