Loading...
HomeMy WebLinkAboutWQ0043657_Application (FTSE)_20220909Date: 08/03/2022 To: NCDEQ Mooresville Regional Office — Water Quality Section 610 E. Center Avenue Mooresville, North Carolina 28115 From: BGE, Inc. / Andrew Grant / Laine Krysl Reference: Galloway Townhomes Transmittal RECEIVED/NCDEQ/DWR AUG ®5 2022 WQROS MOORESVILLE REGIONAL OFFICE Item No. 1. Number of Copies 2 Description Fast Track Application (Form: FTA 06-21) 2. 2 LLC NC Registration 3. 2 Developers Agreement 4. 2 8.5"x11" Color USGS Topographic Site Map 5. 2 8.5"xl 1" Color Aerial Site Map 6. 2 Flow Tracking/Acceptance Form (Form: FTSE 10-18) 7. 1 Application Fee — Check ($480.00) 8. 2 Onsite approved Utility Plan, Profile and Detail Sheets Comments: The proposed sewer lines of interest consist of approx. 1,194 L.F. of private 8" PVC pipe, a pump station and 514 L.F. of 4" PVC force main which will serve 63 townhome units and an amenity. Please see the attached Utility Plan for the location of this sewer lines. BGE, Inc. (980) 220-2322 Andrew Grant agrant@bgeinc.com Laine Krysl lkrysl @bgeinc.com Serving. Leading. Solving.'' 1111 Metropolitan Avenue, Suite 250 • Charlotte, North Carolina 28204 • 980-220-2322 RECEIVED/NCDEQ/DWR AUG - 5 2022 WQROS MOORESVILLE REGIONAL OFFICE August 3, 2022 W. Corey Basinger, Regional Supervisor NCDEQ Division of Water Resources Mooresville Regional Office 610 E. Center Avenue Mooresville, NC 28115 RE: Galloway Road Townhomes — Fast Track Sewer System Extension Application Dear Mr. Basinger: Enclosed is the application and supporting documentation for the Fast Track Sewer System Extension Application for the Galloway Road Townhomes project located on tax parcel 02911104 at Galloway Road and John Adams Road in the City of Charlotte, Mecklenburg County, NC. This townhome development proposes 63 — 3-bedroom townhome units and a proposed amenity center consisting of a pool and clubhouse, these total for an estimated daily sewer flow of 15,979 gallons per day. The sewer system is approximately 1,194 LF of 8" gravity sewer line connecting to the proposed Galloway Pump Station. The Galloway Pump Station discharges through approximately 514 LF of proposed 4" forcemain connecting to the proposed public gravity sewer manhole within Galloway Road. After the forcemain connection, the public proposed gravity sewer line continues down John Adams Road and connects to the existing City of Charlotte gravity sewer line. Please contact me at AGrant@BGEinc.com or (803) 322-7510 if you require any additional information for this application. Sincerely, Andrew P. Grant, PE Director, Land/Site Serving. Leading. Solving."' 1111 Metropolitan Avenue. Suite 250 Charlotte, North Carolina 28204 980-220-2322 Division of Water Resources State of North Carolina Department of Environmental Quality Division of Water Resources 15A NCAC 02T .0300 — FAST TRACK SEWER SYSTEM EXTENSION APPLICATION FTA 04-16 & SUPPORTING DOCUMENTATION Application Number,/ tX U (R3 1 (to be completed by DWR) All items must be completed or the application will be returned I. APPLICANT INFORMATION: WQROS MOORESVILLE REGIONAL OFFICE 1. Applicant's name: 1124 Galloway LLC (company, municipality, HOA, utility, etc.) 2. Applicant type: ❑ Individual ►/ Corporation ❑ General Partnership ❑ Privately -Owned Public Utility ❑ Federal ❑ State/County —I Municipal ❑ Other 3. Signature authority's name: Mark L. Maynard, Sr. per 15A NCAC 02T .0106(b) Title:Manager 4. Applicant's mailing address: 332 Military Cutoff Rd. City: Wilmington State: NC Zip: 28405- 5. Applicant's contact information: Phone number: (910) 612-3633 Email Address: jr(7a,tributecompanies.com RECEIVED/NCDEQ/DWI AUG - 5 2022 II. PROJECT INFORMATION: 1. Project name: Galloway Road Townhotnes 2. Application/Project status: Proposed (New Permit) ❑ Existing Permit/Project If a modification, provide the existing permit number: WQ00 and issued date: If new construction but part of a master plan, provide the existing permit number: WQ00 3. County where project is located: Mecklenburg 4. Approximate Coordinates (Decimal Degrees): Latitude: 35.340523° Longitude: -80.739171° 5. Parcel ID (if applicable): 02911104 (or Parcel ID to closest downstream sewer) III. CONSULTANT INFORMATION: 1. Professional Engineer: Andrew P. Grant, PE Firm: BGE, Inc. Mailing address: 1111 Metropolitan Avenue, Suite 250 City: Charlotte State: NC Zip: 28204- Phone number: (980) 500-8951 Email Address: agrantna,bgeinc.com License Number: 044291 IV. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION: 1. Facility Name: Owner Name: Permit Number: V. RECEIVING DOWNSTREAM SEWER INFORMATION (if different than WWTF): 1. Permit Number(s): WQ Downstream (Receiving) Sewer Size: inch Systein Wide Collection System Permit Number(s) (if applicable): WQCS Owner Name(s): FORM: FTA 04-16 Page 1 of 5 VI. GENERAL REQUIREMENTS 1. If the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached? 0 Yes ❑No ►1N/A 2. If the Applicant is a Developer of lots to be sold, has a Developer's Operational A rc ement (FORIyi: DEV been attached? ® Yes ❑No ❑N/A 3. If the Applicant is a Hon e/Pro peA reement (FORM: HQA) been attached? 0 Yes ❑No ®N/A 4. Origin of wastewater: (check all that apply): ® Residential Owned ❑ Residential Leased ❑ School / preschool / day care ❑ Food and drink facilities 0 Businesses / offices / factories ❑ Retail (stores, centers, malls) 0 Retail with food preparation/service 0 Medical / dental / veterinary facilities 0 Church 0 Nursing Home 5. Nature of wastewater : 100 % Domestic/Commercial % Commercial % Industrial (See 15A .NCAC 02T .0103(20)) >Is there a Pretreatment Program in effect? 0 Car Wash 0 Hotel and/or Motels ® Swimming Pool /Clubhouse 0 Swimming Pool/Filter Backwash 0 Other (Explain in Attachment) 0 Yes 0 No 6. Has a flow reduction been approved under 15A NCAC 02T .0114(0? ❑ Yes ►1 No > If yes, provide a copy of flow reduction approval letter 7. Summarize wastewater generated by project: Establishment Type (see 02T,0114(f)) Daily Design Flow a,b No. of Units Flow 3 bedroom residential townhome 190 gal/townhome unit 63 units 11,970 GPD Pool 10 gal/person (1 person / 15 sf) 401 people (6,014 sf) 4009 GPD gal/ GPD gal/ GPD gal/ GPD gal/ GPD Total 15,979 GPD a See 15A NCAC 02T .0114(b), (d (e}{1) and ie)(2} for caveats to wastewater design flow rates (i.e., minimum flow per dwelling; proposed unknown non-residential development uses; public access facilities located near high public use areas; and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in G.S. 42A-4). b Per 15A NCAC 02T .0114(c), design flow rates for establishments not identified [in table 15A NCAC 02T.01 14] shall be determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data. 8. Wastewater generated by project: 15,979 GPD (per 15A NCAC 02T .0114) > Do not include future flows or previously permitted allocations If permitted flow is zero, indicate why: ❑ Pump Station or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line 0 Flow has already been allocated in Permit Number: 0 Rehabilitation or replacement of existing sewer with no new flow expected ❑ Other (Explain): FORM: FTA 04-16 Page 2 of 5 VII. GRAVITY SEWER DESIGN CRITERIA (If Applicable) - 02T ,00 & MDC (Grayity Sewers): 1. Summarize gravity sewer to be permitted: Size (inches) Length (feet) Material 8 1,194 PVC ➢ Section II & III of the MDC for Permitting of Gravity Sewers contains information related to design criteria ➢ Section III contains information related to minimum slopes for gravity sewer(s) ➢ Oversizing lines to meet minimum slope requirement is not allowed and a violation of the MDC VIII. PUMP STATION DESIGN CRITERIA (If Applicable) — 02T .0305 & MDC (Pump Stations/Force Mains : COMPLETE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT 1. Pump station number or name: Galloway Pump Station 2. Approximate Coordinates (Decimal Degrees): Latitude: 35.340776° Longitude: -80.739789° 3. Design flow of the pump station: 0.101 millions gallons per day (firm capacity) 4. Operational point(s) of the pump(s): 106 gallons per minute at 26.0 feet total dynamic head (TDH) 5. Summarize the force main to be permitted (for this Pump Station): Size (inches) Length (feet) Material 4 514 PVC 6. Power reliability in accordance with 15A NCAC 02T .0305(h)(1): Standby power source or pump with automatic activation and telemetry - 15A NCAC 02T .0305(h)(1)(B): ➢ Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day A Must be permanent to facility Or if the pump station has an average daily flow less than 15,000 gallons per day: ❑ Portable power source with manual activation, quick -connection receptacle and telemetry - 15A NCAC 02T .0305(h)(1)(C) or ❑ Portable pumping unit with plugged emergency pump connection and telemetry - 15A NCAC 02T .0305(h)(1)(C): A It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant (draft agreement) and is compatible with the station. ➢ If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided in the case of a multiple station power outage. FORM: FTA 04-16 Page 3 of 5 IX. SETBACKS & SEPARATIONS — (02B .0200 & 15A NCAC 02T .0305(f)): 1. Does the project comply with all separations found in 15A NCAC 02T.0305(1) & (g) ➢ 15A NCAC 02T.0305(f) contains minimum separations that shall be provided for sewer systems: ®Yes No Setback Parameter* Separation Required Storm sewers and other utilities not listed below (vertical) 24 inches Water mains (vertical -water over sewer including in benched trenches) 18 inches Water mains (horizontal) 10 feet Reclaimed water lines (vertical - reclaimed over sewer) 18 inches Reclaimed water lines (horizontal - reclaimed over sewer) 2 feet **Any private or public water supply source, including any wells, WS-I waters of Class I or Class II impounded reservoirs used as a source of drinking water 100 feet **Waters classified WS (except WS-I or WS-V), B, SA, ORW, HQW, or SB from normal high water (or tide elevation) and wetlands (see item IX.2) 50 feet **Any other stream, lake, impoundment, or ground water lowering and surface drainage ditches 10 feet Any building foundation 5 feet Any basement 10 feet Top slope of embankment or cuts of 2 feet or more vertical height 10 feet Drainage systems and interceptor drains 5 feet Any swimming pools 10 feet Final earth grade (vertical) 36 inches > 15A NCAC 02T.0305(g) contains alternatives where separations in 02T.0305(f) cannot be achieved. ➢ **Stream classifications can be identified using the Division's NC Surface Water Classifications weba ➢ If noncompliance with 02T.0305 orb see Section X of this application 2. Does the project comply with separation requirements for wetlands? (50 feet of separation) ❑ Yes ❑ No ►1 N/A ➢ See the Division's draft separation requirements for situations where separation cannot be meet > No variance is required if the alternative design criteria specified is utilized in design and construction ➢ As built documents should reference the location of areas effected 3. Does the project comply with setbacks found in the river basin rules per 15A NCAC 02B .0200? // Yes ❑ No ❑ N/A ➢ This would include Trout Buffered Streams per 15A NCAC 2B.0202 4. Does the project require coverage/authorization under a 404 Nationwide or individual permits or 401 Water Quality Certifications? ➢ Information can be obtained from the 401 & Buffer Permitting Branch ® Yes ❑ No 5. Does project comply with 15A NCAC 02T.0105(c)(c) (additional permits/certifications)? ® Yes ❑ No Per 15A NCAC 02T.0105 c)(6), directly related environmental permits or certification applications are being prepared, have been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent permits (erosion and sedimentation control plans, stormwater management plans, etc.). 6. Does this project include any sewer collection lines that are deemed "high -priority?" Per 15A NCAC 02T,0402, "high -priority sewer" means "any aerial sewer, sewer contacting surface waters, siphon, or sewer positioned parallel to streambanks that is subject to erosion that undermines or deteriorates the sewer. ❑ Yes ® No ❑ N/A > If yes, include an attachment with details for each line, including type (aerial line, size, material, and location). High priority lines shall be inspected by the permittee or its representative at least once every six -months and inspections documented per 15A NCAC 02T.0403(a)(5) or the permitee's individual System -Wide Collection permit. FORM: FTA 04-16 Page 4 of 5 X. CERTIFICATIONS: 1. Does the submitted system comply with 15A NCAC 02T, the Minunum Design Criteria for the Permitting of Pump Stations and Force Mains (latest version), and the Gravity Sewer Minimum Design Criteria (latest version) as applicable? ® Yes ❑ No IfNo, complete and submit the Variance/Alternative Design Request application (VADC 10-14) and supporting documents for review. Approval of the request is required prior to submittal of the Fast Track Application and supporting documents. 2. Professional Engineer's Certification: Otia W Q. CIRa - T (Professional Engineer's name from Application Item 1II.1.) attest that this application for has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans, specifications, engineering calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains (latest version). Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. NOTE — In accordance with General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000, as well as civil penalties up to $25,000 per violation. North Carolina Professional Engineer's seal, signature, and date: 3. Applicant's Certification per 15A NCAC 02T .0106(b): I, 0 \\ cys� C cam' �a \C' sz i— (Signature Authority's name & title from Apixlication Item I.3.) 11411114,1114,4 SEAL - 044291 47, attest that this application for has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. I understand that any discharge of wastewater from this non - discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties, injunctive relief, and/or criminal prosecution. I will make no claim against the Division of Water Resources should a condition of this permit be violated. I also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. NOTE — In accordance with General Statutes 143-215.6A and I43-215.6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. Signature: Date: FORM: FTA 04-16 Page 5 of 5 T CAOLIN Department of the Secretary of State To all whom these presents shall come, Greetings: I, Elaine F. Marshall, Secretary of State of the State of North Carolina, do hereby certify the following and hereto attached to be a true copy of ARTICLES OF ORGANIZATION OF 1124 GALLOWAY LLC the original of which was filed in this office on the 30th day of June, 2020. IN WITNESS WHEREOF, I have hereunto set my hand and affixed my official seal at the City of Raleigh, this 30th day of June, 2020. Scan to verify online. Certification# C202018200587-1 Reference# C202018200587-1 Page: 1 of 3 Verify this certificate online at https://www.sosnc.govfverification Secretary of State STATE OF NORTH CAROLINA COUNTY OF Mecklenburg Permit No. DEVELOPER'S OPERATIONAL AGREEMENT This AGREEMENT made pursuant to G.S. 143-215.1 (di) and entered into this 26th day of April 2022 , by and between the North Carolina Environmental Management Commission, an agency of the State of North Carolina, hereinafter known as the COMMISSION; and 1124 Galloway LLC , a corporation/general partnership registered/licensed to do business in the State of North Carolina, hereinafter known as the DEVELOPER. WITNESSETH: 1. The DEVELOPER is the owner of the certain lands lying in Mecklenburg County, upon which it is erecting and will erect dwelling units and other improvements, said development to beknown as Galloway Road Townhomes (hereinafter the Development). 2. The DEVELOPER desires, to construct a wastewater collection system with pumps, wastewater treatment works, and/or disposal facilities (hereinafter Disposal System) to provide sanitary sewage disposal to serve the Development on said lands. 3. The DEVELOPER has applied to the COMMISSION for the issuance of a permit pursuant to G.S. 143- 215.1 to construct, maintain, and operate the Disposal System. 4. The DEVELOPER has created or shall create unit ownership in said dwellings units, other improvements and lands through filing of a Declaration of Unit Ownership (hereinafter Declaration), pursuant to Chapter 47C or 47F of the North Carolina General Statutes. 5. The DEVELOPER has caused to be formed or will cause to be formed at the time of filing of the Declaration, 1124 Galloway LLC - Galloway Road Townhomes (hereinafter Association), a non-profit corporation organized and existing under and by the virtue of the laws of the State of North Carolina, for the purpose, among others, of handling the property, affairs and business of the Development; of operating, maintaining, re -constructing and repairing the common elements of the lands and improvements subject to unit ownership, including the Disposal System; and of collecting dues and assessments to provide funds for such operation, maintenance, re -construction andrepair. 6. The COMMISSION desires to assure that the Disposal System of the Development is properly constructed, maintained and operated in accordance with law and permit provisions in order to protect the quality of the waters of the State and the public interest therein. NOW, THEREFORE, in consideration of the promises and the benefits to be derived by each of the parties hereto, the COMMISSION and DEVELOPER do hereby mutually agree as follows: 1. The DEVELOPER shall construct the Disposal System in accordance with the permit and plans and specifications hereafter issued and approved by the COMMISSION, and shall thereafter properly operate and maintain such systems and facilities in accordance with applicable permit provisions andlaw. 2. The DEVELOPER shall not transfer ownership and/or control of the Disposal System to the Association until construction has been completed in accordance with the permit and approved plans, and the staff of the Division of Water Resources has inspected and approved of the facilities. In order to change the name of the permit holder, the DEVELOPER must request that the permit be reissued to the Association. The request must include a copy of the Association Bylaws and Declaration. 3. The DEVELOPER shall not transfer, convey, assign or otherwise relinquish or release its responsibility for the operation and maintenance of its Disposal System until a permit has been reissued to the DEVELOPER's successor. FORM: DEV 03-19 Page 1 of 2 4. The DEVELOPER shall provide in the Declaration and Association Bylaws that the Disposal System and appurtenances thereto are part of the common elements and shall thereafter be properly maintained and operated in conformity with law and the provisions of the permit for construction, operation, repair, and maintenance of the system and facilities. The Declaration and Bylaws shall identify the entire wastewater treatment, collection and disposal system as a common element which will receive the highest priority for expenditures by the Association except for Federal, State, and local taxes and insurance. 5. The DEVELOPER shall provide in the Declaration and Association Bylaws that the Disposal System will be maintained out of the common expenses. In order to assure that there shall be funds readily available to repair, maintain or construct the Disposal System, beyond the routine operation and maintenance expenses, the Declaration and Association Bylaws shall provide that a fund be created out of the common expenses. Such fund shall be separate from the routine maintenance funds allocated for the facility and shall be part of the yearly budget. 6. In the event the common expense allocation and separate fund are not adequate for the construction, repair, and maintenance of the Disposal System, the Declaration and Association Bylaws shall provide for special assessments to cover such necessary costs. There shall be no limit on the amount of such assessments, and the Declaration and Bylaws shall provide that such special assessments can be made as necessary at any time. 7. If a wastewater collection system and wastewater treatment and/or disposal facility provided by any city, town, village, county, water and sewer authorities, or other unit of government shall hereinafter become available to serve the Development, the DEVELOPER shall take such action as is necessary to cause the existing and future wastewater of the Development to be accepted and discharged into said governmental system, and shall convey or transfer as much of the Disposal System and such necessary easements as the governmental unit mayrequire as condition of accepting the Development's wastewater. 8. Recognizing that it would be contrary to the public interest and to the public health, safety and welfare for the Association to enter into voluntary dissolution without having made adequate provision for the continued proper maintenance, repair and operation of its Disposal System, the DEVELOPER shall provide in the Association Bylaws that the Association shall not enter into voluntary dissolution without first having transferred its said system and facilities to some person, corporation or other entity acceptable to and approved by the COMMISSION by the issuance of apermit. 9. The agreements set forth in numbered paragraphs 1, 2, 3, 4, 5, 6, 7, and 8 above shall be conditions of any permit issued by the COMMISSION to the DEVELOPER for the construction, maintenance, repair and operation of the Disposal System. 10. A copy of this agreement shall be filed at the Register of Deeds in the County(ies) where the Declaration is filed and in the offices of the Secretary of State of North Carolina with the Articles of Incorporation of the Association. IN WITNESS WHEREOF, this agreement was executed in duplicate originals by the duly authorized representative of the parties hereto on the day and year written as indicated by each of the parties named below: FOR THE ENVIRONMENTAL 1124 Galloway LLC MANAGEMENT COMMISSION Name of DEVELOPER Richard E. Rogers, Jr. Director, Division of Water Resources (Signature) Print Name and Ti (Date) (DM FORM: DEV 03-19 Page 2 of 2 0) 1- z 6mp.E6uimwhsivawnaoo6sti„ps,aso\.o ENDED ONLY FOR THE SPECIFIC PURPOSE AND CLIENT FOR WHICH IT WAS PREPARED. REUSE OF AND IMPROPER RELIANCE ON THIS DOCUMENT WITHOUT WRITTEN �c z= or w? oa ❑a 00 a° UC z 0t OC a (- -a 22 6C a SC O� F-c zc w- o0 oC Ia 1- z REUSE OF AND IMPROPER RELIANCE ON THIS DOCUMENT WITHOUT WRITT a O a- rt a N 0 0: ¢Z Zu Ka a iC wf z_ (0a V4'= o- f z� f w3 0 a 0a 6mpOd01 31IS\s\uawgaepy\W2iOlS\Uodaa\sum\einom0 - q0\a((S peon Remope0 sawoH a\ngpl - ZO-LZ£B\saiuedwo0 a(nqu1\spa!Wd\V3NG0 State of North Carolina Department of Environmental Quality Division of Water Resources Flow Tracking for Sewer Extension Applications (FTSE 10-18) Entity Requesting Allocation: BGE, Inc. Project Name for which flow is being requested: Galloway Road Townhomes More than one FTSE may be required for a single project if the owner of the WWTP is not responsible for all pump stations along the route of the proposed wastewater flow. I. Complete this section only if you are the owner of the wastewater treatment plant. a. WWTP Facility Name: Mallard Creek WWTP b. WWTP Facility Permit #: NC0030210 All flows are in MGD c. WWTP facility's permitted flow 12.00 d. Estimated obligated flow not yet tributary to the WWTP 2.005 e. WWTP facility's actual avg. flow f. Total flow for this specific request g. Total actual and obligated flows to the facility h. Percent of permitted flow used 9.375 0.01269 11.393 94.9% II. Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow. List pump stations located between the project connection point and the WWTP: (A) (B) (C) (D)=(B+C) (E)=(A-D) Design Obligated, Pump Pump Average Approx. Not Yet Total Current Station Station Firm Daily Flow** Current Tributary Flow Plus (Name or Permit Capacity, * (Firm / pf), Avg. Daily Daily Flow, Obligated Available Number) No. MGD MGD Flow, MGD MGD Flow Capacity*** * The Firm Capacity (design flow) of any pump station is defined as the maximum pumped flow that can be achieved with the largest pump taken out of service. ** Design Average Daily Flow is the firm capacity of the pump station divided by a peaking factor (pf) not less than 2.5, per Section 2.02(A)(4)(c) of the Minimum Design Criteria. *** A Planning Assessment Addendum shall be attached for each pump station located between the project connection point and the WWTP where the Available Capacity is < 0. Downstream Facility Name (Sewer): Unknown Downstream Permit Number: Unknown Page 1 of 6 FTSE 10-18 III. Certification Statement: Keri Cantrell certify to the best of my knowledge that the addition of the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances, given the implementation of the planned improvements identified in the planning assessment where applicable. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items listed above in Sections I and II plus all attached planning assessment addendums for which I am the responsible party. Signature of this form certifies that the receiving collection system or treatment works has adequate capacity to transport and treat the proposed new wastewater. Digitally signed by Keri Cantrell Date: 2022.05.06 10:25:17 -04'00' Adobe Acrobat version: 2022.001.20085 5/6/2022 Signing Official Signature Date Chief Engineer Title of Signing Official Page 2 of 6 FTSE 10-18 CHARLOTTE May 9, 2022 Mr. David Hall BGE, Inc. 1111 Metropolitan Avenue Charlotte, NC 28204 SUBJECT: WATER AND SEWER FLOW ACCEPTANCE GALLOWAY ROAD TOWNHOMES 1124 GALLOWAY ROAD, CHARLOTTE, NC 28262 CLTWATER TRACKING# 20223377 After an analysis of the sanitary sewer associated with the proposed design of project, 20223377, GALLOWAY ROAD TOWNHOMES, it was determined that there is sufficient capacity to accommodate the proposed sewer flow of 12,690 gallons per day (63 units x 190 gpd/unit; 72 people x 10 gpd/person) at the connection point(s) indicated on the submitted utility plan for transmission to the Mallard Creek Wastewater Treatment Plant; NPDES permit number NC0030210, for treatment. This acceptance of flow is based upon the existing capacity of the designated publicly owned treatments works. Please see attached NCDEQ-FTSE form. Charlotte Water (CLTWater) agrees to furnish water to the subject project. The water quality to the subject project is regulated by the State Drinking Water Act Amendments of 1986 and The Water Supply Management Plan, PWS ID # 0160010 on file with the Public Water Supply Section of NCDEQ. However, CLTWater cannot guarantee a constant pressure or quality of flow. The applicant should understand that due to the involvement of other agencies and continuing growth of the water system, the ability to provide service for future projects cannot be guaranteed nor reserved. Connection to the CLTWater system is accepted on a first come, first served basis. The applicant should understand that this letter is not authorization to construct or extend private water or sewer systems, as the appropriate local or State permits are required prior to construction. If the appropriate authorization to construct permits are not obtained, and construction has not started within two (2) years of issuance of this flow acceptance, and payment for any service connections have not been received within two (2) years of issuance of this flow acceptance letter, this flow acceptance approval shall be rescinded, and a new flow acceptance request must be made. The CAP analysis performed determines available capacity within the existing public gravity sewer system. The developer is responsible for any additional private or public sewer infrastructure required to convey flow from the proposed development to the existing public gravity sewer. If you have any questions, please do not hesitate to contact me at (704) 432-5801. Sincerely, Guki U rm.v- A Kac,L& Guillermo Anzola / Engineering Assistant CHARLOTTE WATER Charlotte Water 5100 Brookshire Blvcl, Charlotte, NC 28216 charlottewater.org OP Operated by the City of Charlotte North Carolina Secretary of State Search Results Page 1 of 1 • File an Annual Report/Amend an Annual Report • Upload a PDF Filing • Order a Document Online • Add Entity to My Email Notification List • View Filings • Print a Pre -Populated Annual Report form • Print an Amended a Annual Report form Limited Liability Company Legal Name 1124 Galloway LLC Information Sosld: 2003786 Status: Current -Active Date Formed: 6/30/2020 Citizenship: Domestic Annual Report Due Date: April 15th CurrentAnnual Report Status: Registered Agent: Hollis, Robert J, Addresses Mailing Principal Office Reg Office 332 Military Cutoff Rd 332 Military Cutoff Rd 332 Military Cutoff Rd Wilmington, NC 28405 Wilmington, NC 28405 Wilmington, NC 28405 Reg Mailing 332 Military Cutoff Rd Wilmington, NC 28405 Company Officials All LLCs are managed by their managers pursuant to N.C.G.S. 57D-3-20. Manager Mark L Maynard , Sr 332 Military Cutoff Rd Wilmington NC 28405 https://www.sosnc.gov/online_services/search/Business Registration_Results 8/5/2022