Loading...
HomeMy WebLinkAboutSW4220503_Supplement-EZ Form_20220909Sp IDDI C1IACAIT C7 li-MIED DAIr_`C DocuSign Envelope ID: 8BCF71 FB-66B3-4F5F-A569-3ADB12BD66EA I FORMS LOADED I PROJECT INFORMATION 1 lProiect Name Project Area (ac) Coastal Wetland Area (ac) Surface Water Area (ac) Is this project High or Low Density? Does this project use an off -site SCM? CANE CREEK - PHASE 8 44.31 N/A 1.05 LOW NO COMPLIANCE WITH 02H .1003(4) 7 Width of vegetated setbacks provided feet N/A 8 Will the vegetated setback remain vegetated? N/A 9 If BUA is proposed in the setback, does it meet NCAC 02H.1003 4 c-d ? No 10 I Is streambank stabilization proposed on this project? No NUMBER AND TYPE OF SCMs: 11 Infiltration S stem 0 12 Bioretention Cell 0 13 Wet Pond 0 14 Stormwater Wetland 0 15 Permeable Pavement 0 16 Sand Filter 0 17 Rainwater Harvesting RWH 0 18 Green Roof 0 19 Level Spreader -Filter Strip LS-FS 0 20 Disconnected Impervious Surface (DIS) 0 21 Treatment Swale 13 22 Dry Pond 0 23 StormFilter 0 24 Silva Cell 0 25 JBayfilter 0 26 1 Filterra 0 FORMS LOADED DESIGNER CERTIFICATION 27 Name and Title: TOM SPEIGHT JR., PLS, PE 28 Or anization: BATEMAN CIVILSURVEY COMPANY 29 Street address: 2524 RELIANCE AVENUE 30 City, State, Zip: APEX, NC 27539 31 Phone numbers : 919.577.1080 32 Email: meggan.masters@batemancivilsurvey.com Certification Statement: I certify, under penalty of law that this Supplement-EZ form and all supporting information were prepared under my direction or supervision, that the information provided in the form is, to the best of my knowledge and belief, true, accurate, and complete, and that the engineering plans, specifications, operation and maintenance agreements and other supporting information are consistent with the information provided here. \1t, 1r IA V Re0 +rrr r7 +AS 1 •• SEAL- � — 20234 ol 14�y4�. r�H11�1l II1111511\ Seal IDocuSigned by: 1V"Ma.s S • 09838E23DC404AD... Signature of Designer 09.07.22 Date DRAINAGE AREAS 1 Is this a high density project? No 2 If so, number of drainage areas/SCMs 0 3 Does this roiect have low densit areas? Yes 4 If so, number of low density drainage areas 1 5 Is all/part of this project subject to previous rule versions? No FORMS LOADED AREA INFORMATION Entire Site LID 1 4 T pe of SCM N/A N/A 5 Total drainage area (sq ft 1 975 543 11975,543 6 Onsite drainage area (sq ft 1 975 543 11975,543 7 Offsite drainage area (sq ft 0 0 8 Total BUA in project (sq ft 236,907 236,907 9permitting) New BUA on subdivided lots (subject to s ft 139,536 139,536 10permitting) New BUA not on subdivided lots (subject to s 94,179 94,179 11 Offsite BUA (sq ft 0 0 12 1 Breakdown of new BUA not on subdivided lots: Parking (sq ft 0 0 Sidewalk (sq ft 0 0 Roof (sq ft 0 0 Roadway s ft 94,179 94,179 Future (sq ft 0 0 Other, please specify in the comment box below (sq ft n/a n/a 13 New infiltrating permeable pavement on subdivided lots (sq ft n/a n/a 14 New infiltrating permeable pavement not on subdivided lots (sq ft n/a n/a 15permitting) Existing BUA that will remain (not subject to s ft 3,196 3,196 16 Existing BUA that is already permitted (sq ft 0 0 17 Existing BUA that will be removed (sq ft 0 0 18 Percent BUA 12 12 19 Design storm inches n/a n/a 20 Design volume of SCM cu ft n/a n/a 21 Calculation method for design volume n/a n/a ADDITIONAL INFORMATION 22 Please use this space to provide any additional information about the drainage area(s): ALL DRAINAGE GOES TO (1) ANALYSIS POINT. THE CORRECT BUA PERCENT IS 11.53%, HOWEVER LINE 18 IS AUTOFILLING TO THE ROUNDED 12. LOW DENSITY DESIGN 1 REQUIREMENTS FOR LOW DENSITY PROJECTS FROM 02H .1003 Is project below density thresholds set forth in the applicable stormwater rule? Yes 2 Does project maximize dispersed flow and minimize channelization of flow? Yes 3 Has the use of piping been minimized per .1003(2)(c)? Yes 4 Side slopes of the vegetated conveyances (H:V) (3:1) 5 Maximum velocity in the vegetated conveyances during the 10-year storm? 13.51 6 lAre curb outlet swales proposed? No 7 Maximum longitudinal slope of curb outlet swale(s) (%) 0 8 Bottom width of curb outlet swale(s) (feet) 9 Maximum side slope of curb outlet swale(s) (H:V) 10 Minimum length of curb outlet swale(s) (feet) 11 Are treatment swales used instead of curb outlet swales? No 12 1 Is stormwater released at the edge of the setback as dispersed flow? Yes 13 1 Have stormwater outlets been designed to prevent downslope erosion? Yes 14 JAre variations to rule .1003 proposed? No ADDITIONAL INFORMATION 15 Please use this space to provide any additional information about this low density project: Swale # Drainage Area ac BUA (ac) Pervious area ac C Q (cfs) Slope ( % ) Va„o„, (fps) Va-a, (fps) Flow depth (ft) 1 3.30 0.53 2.77 0.50 2.23 4.65 3.62 3.62 0.25 2 0.61 0.17 0.44 0.50 0.42 4.29 2.41 2.41 0.08 3 4.75 0.82 3.93 0.50 3.23 4.98 3.94 3.94 0.29 4 0.88 0.10 0.78 0.50 0.59 4.78 2.22 2.22 0.12 5 0.76 0.16 0.60 0.50 0.51 5.88 2.29 2.29 0.08 6 0.28 0.06 0.22 0.50 0.19 1.00 0.99 0.99 0.09 7 3.39 0.53 2.86 0.50 2.44 5.50 4.38 4.38 0.50 8 0.93 0.53 0.40 0.50 1.36 4.79 3.00 3.00 0.17 9 0.50 0.23 0.27 0.50 0.35 3.51 2.32 2.32 0.08 10 1.10 0.33 0.77 0.50 0.76 4.27 2.61 2.61 0.17 11 0.34 0.11 0.23 0.50 0.23 5.78 1.97 1.97 0.08 12 0.36 0.12 0.24 0.50 0.32 5.67 1.97 1.97 0.08 13 0.34 0.11 0.23 0.50 0.23 1.91 1.23 1.23 0.08 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 TREATMENT SWALE 11 Drainage area number 21 Design flow rate of SCM GENERAL MDC FROM 02H .1050 TS 1 TS 2 TS 3A TS 3E TS 4 TS 5A 169.87 cfs 163.30 cfs 175.83 cfs 172.36 cfs 191.15 cfs 78.80 cfs 3 Is the SCM sized to treat the SW from all surfaces at build -out? Yes Yes Yes Yes Yes Yes 4 Is the SCM located away from contaminated soils? Yes Yes Yes Yes Yes Yes 5 What are the side slopes of the SCM (H:V)? 3:1 3:1 3:1 3:1 3:1 3:1 6 Does the SCM have retaining walls, gabion walls or other engineered side slopes? No No No No 7 Are the inlets, outlets, and receiving stream protected from erosion (10-yearstorm)? Yes Yes Yes Yes Yes Yes 8 Is there an overflow or bypass for inflow volume in excess of the design volume? No No No No No No 9 What is the method for dewatering the SCM for maintenance? Other Other Other Other Other Other 10 If applicable, will the SCM be cleaned out after construction? N/A N/A N/A N/A N/A N/A 11 Does the maintenance access comply with General MDC (8)? Yes Yes Yes Yes Yes Yes 12 Does the drainage easement comply with General MDC (9)? Yes Yes Yes Yes Yes Yes 13 If the SCM is on a single family lot, does (will?) the plat comply with General MDC 10 ? Yes Yes Yes Yes Yes Yes 14 Is there an O&M Agreement that complies with General MDC (11)? Yes Yes Yes Yes Yes Yes 15 Is there an O&M Plan that complies with General MDC (12)? Yes Yes Yes Yes Yes Yes 16 Does the SCM follow the device specific MDC? Yes Yes Yes Yes Yes Yes 17 Was the SCM designed by an NC licensedprofessional? Yes Yes Yes Yes Yes Yes TREATMENT SWALE MDC FROM 02H .1061 18 SHWT elevation (fmsl) 473 471 497.5 496.5 490 516 19 Bottom of the treatment swale (fmsl) 476.00 474.00 502.50 501.50 495.00 521.00 20 Depth of treatment swale (feet) 2 ft 2 ft 2 ft 2 ft 2 ft 2 ft 21 Is the swale trapezoidal in shape? Yes Yes Yes Yes Yes Yes 22 Width of bottom of swale (feet) 2 ft 2 ft 2 ft 2 ft 2 ft 2 ft 23 Side slopes of treatment swale (H:V) 3:1 3:1 3:1 3:1 3:1 3:1 24 Length of swale (feet) 581 ft 638 ft 472 ft 135 ft 277 ft 200 ft 25 Flow depth during the 0.75 inch/hour storm (inches) 3 in 1 in 3 in 1 in 1 in 1 in 26 Flow velocity during the 0.75 inch/hour storm (feet per second) 4 ft/s 2 ft/s 4 ft/s 2 ft/s 2 ft/s 1 ft/s 27 Hydraulic retention time for swale (minutes) 5 min 5 min 5 min 5 min 5 min 5 min 281 Species of grass that will be used Liner Liner Liner Liner Liner Liner 29 Will the grass be maintained at an average height of 6 inches? Yes Yes Yes Yes Yes Yes 30 Will the grass not be cut lower than 4 inches? Yes Yes Yes Yes Yes Yes 31 Velocity during the 10-year storm (feet per second) 4 ft/s 3 ft/s 5 ft/s 3 ft/s 3 ft/s 1 ft/s 32 Is the swale designed to non-erosively pass the 10-year storm? Yes Yes Yes Yes Yes Yes INFORMATION ADDITIONAL 33 Please use this space to provide any additional information about the treatment swale(s): TREATMENT SWALE 11 Drainage area number TS 5B TS 6 TS 7 TS 8 TS 9 TS 10 21 Design flow rate of SCM cfs 283.30 cfs 172.46 cfs 147.63 cfs 162.83 cfs 189.45 cfs 187.64 cfs GENERAL MDC FROM 02H .1050 3 Is the SCM sized to treat the SW from all surfaces at build -out? Yes Yes Yes Yes Yes Yes 4 Is the SCM located away from contaminated soils? Yes Yes Yes Yes Yes Yes 5 What are the side slopes of the SCM (H:V)? 3:1 3:1 3:1 3:1 3:1 3:1 6 Does the SCM have retaining walls, gabion walls or other engineered side slopes? 7 Are the inlets, outlets, and receiving stream protected from erosion (10-yearstorm)? Yes Yes Yes Yes Yes Yes 8 Is there an overflow or bypass for inflow volume in excess of the design volume? No No No No No No 9 What is the method for dewatering the SCM for maintenance? Other Other Other Other Other Other 10 If applicable, will the SCM be cleaned out after construction? N/A N/A N/A N/A N/A N/A 11 Does the maintenance access comply with General MDC (8)? Yes Yes Yes Yes Yes Yes 12 Does the drainage easement comply with General MDC (9)? Yes Yes Yes Yes Yes Yes 13 If the SCM is on a single family lot, does (will?) the plat comply with General MDC 10 ? Yes Yes Yes Yes Yes Yes 14 Is there an O&M Agreement that complies with General MDC (11)? Yes Yes Yes Yes Yes Yes 15 Is there an O&M Plan that complies with General MDC (12)? Yes Yes Yes Yes Yes Yes 16 Does the SCM follow the device specific MDC? Yes Yes Yes Yes Yes Yes 17 Was the SCM designed by an NC licensedprofessional? Yes Yes Yes Yes Yes Yes TREATMENT SWALE MDC FROM 02H .1061 18 SHWT elevation (fmsl) 491 480 477.1 503.5 499 499 19 Bottom of the treatment swale (fmsl) 495.00 485.00 483.10 508.50 504.00 504.00 20 Depth of treatment swale (feet) 3 ft 2 ft 2 ft 2 ft 2 ft 2 ft 21 Is the swale trapezoidal in shape? No Yes Yes Yes Yes Yes 22 Width of bottom of swale (feet) 0 2 ft 2 ft 2 ft 2 ft 2 ft 23 Side slopes of treatment swale (H:V) 3:1 3:1 3:1 3:1 3:1 3:1 24 Length of swale (feet) 473 ft 482 ft 725 ft 525 ft 467 ft 361 ft 25 Flow depth during the 0.75 inch/hour storm (inches) 6 in 2 in 1 in 2 in 1 in 1 in 26 Flow velocity during the 0.75 inch/hour storm (feet per second) 4 ft/s 3 ft/s 2 ft/s 3 ft/s 2 ft/s 2 ft/s 27 Hydraulic retention time for swale (minutes) 5 min 5 min 5 min 5 min 5 min 5 min 281 Species of grass that will be used Liner Liner Liner Liner Liner Liner 29 Will the grass be maintained at an average height of 6 inches? Yes Yes Yes Yes Yes Yes 30 Will the grass not be cut lower than 4 inches? Yes Yes Yes Yes Yes Yes 31 Velocity during the 10-year storm (feet per second) 5 ft/s 4 ft/s 2 ft/s 3 ft/s 2 ft/s 3 ft/s 32 Is the swale designed to non-erosively pass the 10-year storm? Yes Yes Yes Yes Yes Yes INFORMATION ADDITIONAL 33 Please use this space to provide any additional information about the treatment swale(s): TREATMENT SWALE Drainage area number 21Design flow rate of SCM ENERAL MDC FROM 02H .1050 TS 11 108.90 cfs 3 Is the SCM sized to treat the SW from all surfaces at build -out? Yes 4 Is the SCM located away from contaminated soils? Yes 5 What are the side slopes of the SCM (H:V)? 3:1 6 Does the SCM have retaining walls, gabion walls or other engineered side slopes? 7 Are the inlets, outlets, and receiving stream protected from erosion (10-yearstorm)? Yes No 8 Is there an overflow or bypass for inflow volume in excess of the design volume? 9 What is the method for dewatering the SCM for maintenance? Other 10 If applicable, will the SCM be cleaned out after construction? N/A 11 Does the maintenance access comply with General MDC (8)? Yes 12 Does the drainage easement comply with General MDC (9)? Yes 13 If the SCM is on a single family lot, does (will?) the plat comply with General MDC 10 ? Yes 14 Is there an O&M Agreement that complies with General MDC (11)? Yes 15 Is there an O&M Plan that complies with General MDC (12)? Yes 16 Does the SCM follow the device specific MDC? Yes 17 Was the SCM designed by an NC licensedprofessional? I Yes -I I --I avvr IV- F-VI vcn .ivvi 18 SHWT elevation (fmsl) 516 19 Bottom of the treatment swale (fmsl) 521.00 20 Depth of treatment swale (feet) 2 ft 21 Is the swale trapezoidal in shape? Yes 22 Width of bottom of swale (feet) 2 ft 23 Side slopes of treatment swale (H:V) 3:1 24 Length of swale (feet) 230 ft 25 Flow depth during the 0.75 inch/hour storm (inches) 1 in 26 Flow velocity during the 0.75 inch/hour storm (feet per second) 1 ft/s 27 Hydraulic retention time for swale (minutes) 5 min 281 Species of grass that will be used Liner 29 Will the grass be maintained at an average height of 6 inches? Yes 30 Will the grass not be cut lower than 4 inches? Yes 31 Velocity during the 10-year storm (feet per second) 2 ft/s 32 Is the swale designed to non-erosively pass the 10-year storm? Yes INFORMATION ADDITIONAL 33 Please use this space to provide any additional information about the treatment swale(s):