HomeMy WebLinkAboutWQ0013398_Monitoring - 04-2022_20220601FORM: NDMR 10-13 NON -DISCHARGE MONITORING REPORT (NDMR) Page
Permit No.: WQ0013398
Facility Name: Sandpiper Bay WWTF
County: Brunswick
Month: April
Year: 2022
PPI: 001
Flow Measuring Point: ❑ Influent 0 Effluent ❑ No flow generaLd
Parameter Monitoring Point: El Influent 2Effluent ❑ Grounclwater Lowering ❑ Surface Water
Parameter Code -►
50050
00310
00600
00665
50060
31616
00610
00625
00620
00400
00530
00076
>
0
E y
0
3
p
m
c
M rn
F
Z
a
m r
~ 0
r6Wd
d
°
M� iY U
`UU° w
LL (�
o
E
<t
w
0 9
~ Y Z
Z
w c a
~= tJi
rn
ro
7
f
24-hr
hre
GPO;
L
g/L
mg/L
mg/L
#/100 mL
mg/L
mg/L
mg/L
su
mg/L
NTU
1
07:00
4
59.00a
0.5
6.9
1
2
07:00
4
55,0 "
0.5
6.9
1
3
07:00
4
64 0p`
0.5
1
4
07:00
4
62,0
_
0.5
_
_
_6.9
6.9
1
5
07:00
4
64,000' :.:
0,5
_
6.9
I
8
07:00
4
64,000
<2
4.3
4
0 5
<1
<Q2
3,33
6.9
<25
1
7
07:00
4
59,000
0.5
69
1
8
07:00
4
55,000
y
0.5
6.9
9
07:00
4
64,000
_
0.5
6.9
1
10
07:00
4
62.00
-
0. 5
6. 9
1
r' r
.
11
07:00
4
62A00 ,
0.5
6 9
12
07:00
4
68 000' ,.,_,
-
0.5
ss
11
,
13
07:00
4
76,000
05
6,9
1
4
;
14
07:00
4
71.000
_
0.5
6.9
1
15
07:00
4
64.000
0.5
69
16
07:00
4
64.000
0.5
6.9
1
17
07:00
4
64,000
0,5
6.9
1
18
07:00
4
62,000
0.5
6.9
19
07:00
4
62•000
05
6.9
1
20
07:00
4
68,000
<2
3.2
1,9
0.5
< 1
<0.2
1 7
1.52
6.9
<2.5
1
21
07:00
4
76,000
0.5
1
6.9
1
22
07:00
4
71,000
0.5
6.9
1
23
07:00
4
64•000
0.5
6.9
1
24
07:00
4
64,000
0.5
6.9
1
_
25
07:00
4
59,000
0.5
6.9
1
26
07:00
4
55,000
0.5
6.9
1
27
07:00
4
64,000
_
0.5
6.9
1
_
28
07:00
4
62,000
0.5
6.9
1
29
07:00
4
64,000
0.5
6.9
1
30
07:00
4
64,000
0.5
6.9
1
31
Average:
63,733
0.00
3,75
3.2E
0.50
1.00
0, OM
1.35
2,43
0.00
1.00
Daily Maximum:
76,000
200
4 30
4.62
0.50
1.00
0.2,
1.70
3.33
6.90
2,50
1.00
Daily Minimum:
55,000
2,00
3,20 t
1.90
0.50
1.00
0.2
1.00
1.52
6.90
2.50
1 DO
Sampling Type:
Recorder
Composite
Coin
Composite
Grab
Grab
Com
Composite
Composite
Grab
Composite
Recorder
Monthly Avg. Limit:
150,000
10
14
Daily Limit:
15
25
6 to 3
10;
10
Sample Frequency:
Continous
2 X Month
2 X Month
2 X Month
5 X week
2 X Month
2 X Month
2 X Month
2 X Month
1 5 X week
2 X Month
Continous
Certified Laboratories
Name: Sunny Wright
Name: Environmental Chemist / Wilimington NC
Name:
Name:
Does all monitoring data and sampling frequencies meet the requirements in Attachment A of your permit? Compliant _X_ Not Compliant _
If the facility is noncompliant, please explain in the space below the reason(s) the facility was not in compliance. Provide in your explanation the date(s) of the non-compliance
and describe the corrective action(s) taken. Attach additional sheets if n
Operator in Responsible Charge (ORC) Certification
Permittee Certification
ORC: Sunny Wright
Permittee:
Certification No.: 28813
Signing Official: Timothy Tilma
Grade: II Phone Numbe1910-880-4178
Has the RC changed sinSe the previous NDDMMR? No
Signing Official's Title: General Manager
Phone Number: 910-470-8084 Permit Exp 5l20120,264
l��T _ �l �l Z 2
Signature Date
Agnature Date
By this signature, I certify that this report is accurrate to best of my
I certify, under penalty of law, that this document and all attachments were prepared under my
knowledge
direction or supervision in accordance with a system designed to assure that all qualified personnel
properly gathered and evaluated the information submitted.
Mail Original and Two Copies to:
Division of Water Resources
Information Processing Unit
1617 Mail Service Center
Raleigh, North Carolina 27699-1617