Loading...
HomeMy WebLinkAboutWQ0011313_Monitoring - 04-2022_20220606FORM: NDMR 05-16 NON -DISCHARGE MONITORING REPORT (NDMR) Page / of --L- Permit No.:,W00011313 Facility Name: Peppertree Resort WWTP County: Carteret Month: April Year: 2022 PPI: 001 Flow Measuring Point: ❑ tnfluent ❑ Effluent ❑ No flow generated Parameter Monitoring Point: ❑ Influent Q Effluent ❑ Groundwater Lowering ❑ Surface Water Parameter Code 01 50050 00310 00940 50060 31616 00610 00625 00620 00600 00400 00665 70300 00530 00630 00615 7p 'i L U iz OU C C• _ y ~ p 3 a � m '6 L t C y F- y t � U E U O It O U R C O E Q L tp C N N CD Y o O Z (p .-� Z C N `N a1 0 O Z Q N ` p y F (n 0 aCn N N _FU = O N O ~ 'QN- N a) 'a N y C 'a O Q O ~ 3 + �L., " Z Z L Z 24-hr hrs GPD mg/L mg/L mg/L #/100 mL mg/L mg/L mg/L mg/L su mg/L mg/L mg/L mg/L mg/L 1 10:30 11,981 11 7.8 2 13:05 17,302 3 1425 14,279 4 11:32 7,521 2 7.8 5 11:51 12,701 5 7.9 6 09:30 8,886 <2.0 5 <1 0.17 2.88 52.5 55.38 7.9 7.2 5.1 52.5 <0.02 7 0915 11,645 8 7.9 8 10:00 10,352 8 7.9 9 11:30 9,931 10 1300 14,000 11 11.00 13,497 5 7.8 12 09:40 14,000 5 7.9 13 0920 13,202 8 7.9 141 09:45 12,716 8 7.8 15 10:30 18,083 5 7.9 16 11:21 18,263 17 12:20 23,502 18 10:00 20,000 5 7.8 19 0930 13,767 8 7.9 201 09:45 18,895 8 7.8 '! 21 10:30 21,906 8 7.9 22 0900 16,575 5 7.8 23 12:50 28,453 24 11:00 14,393 25 09:45 10,963 5 7.9 261 09:00 9,682 5 7.8 27 11:30 25,541 5 7.9 28 0930 9,027 5 7.9 29 08:30 13,904 5 7.8 30 12:30 10,000 31 Average: 14,832 0.00 4.30 1.00 0.17 2.88 52.50 55.38 7.20 5.10 52.50 0.00 Daily Maximum: 28,453 2.00 11.00 1.00 0.17 288 52.50 55.38 7.90 7.20 5.10 52.50 0.02 Daily Minimum: 7,521 2.00 2.00 1.00 0.17 2.88 52.50 55.38 7.80 7.20 5.10 52.50 0.02 Sampling Type: Recorder Composite Composite Grab Grab Composite Composite Composite Composite Grab Composite Composite Composite Monthly Limit: 807000 10 14 4 20 Daily Limit: 43 Sample Frequency: Continuous See Permit 3 X Year 5 X Week See Permit See Permit I See Permit See Permit See Permit 5 X Week See Permit 1 3 X Year See Permit 5 FORM: NDMR 05-16 NON -DISCHARGE MONITORING REPORT (NDMR) Page / of Sampling Person(s) Certified Laboratories Name: Joe Lawrence Name: Environment 1, Inc Name: Name: Does all monitoring data and sampling frequencies meet the requirements in Attachment A of your permit? Compliant ❑ Non -Compliant If the facility is non -compliant, please explain in the space below the reason(s) the facility was not in compliance. Provide in your explanation the date(s) of the non-compliance and describe the corrective action(s) taken. Attach additional sheets if necessary. Operator in Responsible Charge (ORC) Certification Permittee Certification ORC: Robert C. Howard Permittee: Peppertree Atlantic Beach Owner's Association, Inc. Certification No.: 996013 Signing Official: Daniel E. Fortin Grade: WW III Phone Number: 252-393-8720 Signing Official's Title: Operator Responsible in Charge Has the OR anged since the pr io NDMR? ❑ Yes Cj No Phone Number: 252-393-8720 Permit Expiration: 4/13/2023 c- Z�Z� Signature Date Signature Date By this signature, 1 certify that this report is accurrate and complete to the best of my knowledge. I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that all qualified personnel property gathered and evaluated the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations. Mail Original and Two Copies to: - Division of Water Resources _ Infoinnation Processing Unit 1617 Mail Service Center Raleigh, North Carolina 27699-1617 FORM: NDAR-2 05-16 NON -DISCHARGE APPLICATION REPORT (NDAR-2) Page Z , e- Permit No.: W00011313 Facility Name: Peppertree Resort WWTP County: Carteret Month:'April Year: 2022 Did infiltration occur at Site Name: 1 Site Name: 2 Site Name: Site Name: this facility? Area (acres): 0.29 Area (acres): 0.29 Area (acres): Area (acres): ❑ YES ❑ NO Rate (GPD/ft2): 6 Rate (GPD/ft): 6 Rate (GPD/ft2): Rate (GPD/ft): Weather Freeboard Site Infiltrated? ❑ YES ❑ NO Site Infiltrated? ❑ YES ❑ NO Site Infiltrated? ❑ YES ❑ NO Site Infiltrated? ❑ YES ❑ NO of6 '6 o CLNi F :dQ4 -'0 UQ C a E D i Q ~ C C J C LL @ m 0.~ N E �C LL m E _a ~ a J a CC CU O N LL m ' dO a i Q E 0a ~E C J CU OE NCN LL m °F in ft ft gal min GPD/ft2 ft gal min GPD/ft2 ft gal min GPD/ft2 ft gal min GPD/ft2 ft 1 5,990 0.47 5,990 0.47 2 8,651 0.68 8,651 0.68 3 7,139 0.57 7,139 0.57 4 3,760 0.30 3,760 0.30 5 6,350 0.50 6,350 0,50 6 4,443 0.35 4,443 0.35 7 5,822 0.46 5,822 0.46 8 5,151 0.41 5,151 0.41 9 4,965 0.39 4,965 0.39 10 7,000 0.55 7,000 0.55 11 6,748 0.53 6,748 0.53 12 7,000 0.55 7,000 0.55 13 6,601 0.52 6,601 0.52 14 6,358 0.50 6,358 0.50 15 9,041 0.72 9,041 0.72 16 9,131 0.72 9,131 0.72 17 11,751 0.93 11,751 0.93 18 10,000 0.79 10,000 0.79 19 6,883 0.54 6,883 0.54 20 9,447 0.75 9,447 0.75 21 10,953 0.87 10,953 0.87 221 8,287 0.66 8,287 0.66 23 14,226 1.13 14,226 1.13 24 7,196 0.57 7,196 0.57 25 5,481 0.43 5,481 0.43 26 4,841 0.38 4,841 0.38 27 12,770 1.01 12,770 1.01 28 4,513 0.36 4,513 0.36 29 6,952 0.55 6,952 0.55 #VALUE! 30 5,000 0.40 5,000 0.40 31 Monthly Loading (GPD/ft): 0.59 0.59 #VALUE! #DIV/0! Year to Date Loading (GPD/ft): 58.40 58.40 FORM: NDAR-2 05-16 NON -DISCHARGE APPLICATION REPORT (NDAR-2) Page of Did the application rates exceed the limits in Attachment B of your permit? Compliant ❑ Non -Compliant If not a basin, were the sites kept free of vegetation and raked? 01"Compliant ❑ Non -Compliant If not a basin, were there any instances of effluent ponding in or runoff from the sites? Compliant ❑ Non -Compliant If a basin, were there any instances of breakout from the berms? 2�compliant ❑ Non -Compliant Was the onsite automatically activated standby power source tested and operational? E140(mpliant ❑ Non -Compliant If the facility is non -compliant, please explain in the space below the reason(s) the facility was not in compliance. Provide in your explanation the date(s) of the non-compliance and describe the corrective action(s) taken. Attach additional sheets if necessary. Operator in Responsible Charge (ORC) Certification Permittee Certification bert C. Howard F7- Permittee: Peppertree Atlantic Beach Owner's Association, Inc. Certific No.: 996013 Signing Official: Daniel E. Fortin Grade: WW III Phone Number: 252-393-8720 Signing Official's Title: Operator Responsible in Charge Has the ORC changed since the p ous NDAR-2? [I Yes � No Phone Number: 252-393-8720 Permit Exp.: �4• 04/13/2023 il6& c9q. -Z -? Z Z / Z lj� Signature Date Signature Date By this signature, I certify that this report is accurrate and complete to the best of my knowledge. I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that all qualified personnel properly gathered and evaluated the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations. Mail Original and Two Copies to: Division of Water Resources Information_ Processing Unit 1617 Mail Service Center Raleigh, North Carolina 27699-1617