Loading...
HomeMy WebLinkAboutWQ0010689_CEIARR_20220426 SENT VIA ELECTRONIC MAIL ONLY: NO HARD COPY WILL BE MAILED April 26, 2022 Corey Carpentier Email: corey_carpentier@baxter.com Baxter Healthcare Corporation SUBJECT: Compliance Inspection Report Baxter Healthcare DCAR Non-discharge Permit No. WQ0010689 McDowell County Dear Permittee: The North Carolina Division of Water Resources conducted an inspection of the Baxter Healthcare’s DCAR Annual Report on 4/26/2022. This inspection was conducted to verify that the facility is operating in compliance with the conditions and limitations specified in Non-discharge Permit No. WQ0010689. The findings and comments noted during this inspection are provided in the enclosed copy of the inspection report entitled "Compliance Inspection Report". There were no significant issues or findings noted during the inspection and therefore, a response to this inspection report is not required. If you should have any questions, please do not hesitate to contact me at 828-296-4686 or via email at mikal.willmer@ncdenr.gov. Sincerely, Mikal Willmer, Environmental Specialist II Water Quality Regional Operations Section Asheville Regional Office Division of Water Resources, NCDEQ ATTACHMENTS: Inspection Report Ec: LF DocuSign Envelope ID: D64F4551-9DE4-472E-B391-E0B60D20CA47 Compliance Inspection Report Permit:WQ0010689 Effective:12/01/19 Expiration:03/31/25 Owner :Baxter Healthcare Corporation SOC: Contact Person: Region: County: Directions to Facility: McDowell Asheville Corey Carpentier Effective:Expiration:Facility:Baxter Healthcare DCAR 65 Pitt Station Rd Marion NC 28752 Title:Phone:828-756-6636EHS Associate Take NC Hwy. 221 North out of Marion to NCSR 1560 ( located behind Baxter - North Cove). The facility is located on the left. Secondary ORC(s): Phone:Certification:Primary ORC: System Classifications: On-Site Representative(s): Related Permits: WQ0001512 Baxter Healthcare Corporation - North Cove Steam Generation Plant CLRS Secondary Inspector(s): Primary Inspector: Inspection Date:Exit Time:Entry Time: Phone: 04/26/2022 01:40PM 02:21PM Mikal Willmer 828-296-4686 Facility Status: Permit Inspection Type: Reason for Inspection:Inspection Type: Not CompliantCompliant Routine Distribution of Residual Solids (503 Exempt) Annual Report Review Question Areas: Miscellaneous Questions Record Keeping Treatment Pathogen and Vector Attraction (See attachment summary) Page 1 of 4 DocuSign Envelope ID: D64F4551-9DE4-472E-B391-E0B60D20CA47 Inspection Date: Permit: Inspection Type : Owner - Facility: Reason for Visit: WQ0010689 04/26/2022 Annual Report Review Baxter Healthcare Corporation Routine Inspection Summary: Mikal Willmer, with the Asheville Regional Office, conducted a review of Baxter Healthcare’s DCAR Annual Report on April 26, 2022. This review was conducted to determine whether the facility processed and monitored all residuals in compliance with Permit No. WQ0010689. Baxter distributed approximately 1,212 dry tons of boiler ash residuals in 2021. Pathogen and Vector Attraction Reduction are not required for the boiler ash residuals. Metals, Nutrients and Pollutants of Concern: Required quarterly based on tons distributed. All parameters appear to have been sampled, reported and in compliance with permit requirements. Continue to closely monitor SAR values and utilize the revised agreement as needed. Non-Hazardous Waste Characterization: Required once per permit cycle. As a reminder, Baxter will need to submit all hazardous waste characteristics as outlined under section IV.2 of the permit before the end of the permit cycle in 2024. Page 2 of 4 DocuSign Envelope ID: D64F4551-9DE4-472E-B391-E0B60D20CA47 Inspection Date: Permit: Inspection Type : Owner - Facility: Reason for Visit: WQ0010689 04/26/2022 Annual Report Review Baxter Healthcare Corporation Routine Type Yes No NA NE Land Application Distribution and Marketing Record Keeping Yes No NA NE Is GW monitoring being conducted, if required? Are GW samples from all MWs sampled for all required parameters? Are there any GW quality violations? Is GW-59A certification form completed for facility? Is a copy of current permit on-site? Are current metals and nutrient analysis available? Are nutrient and metal loading calculating most limiting parameters? a. TCLP analysis? b. SSFA (Standard Soil Fertility Analysis)? Are PAN balances being maintained? Are PAN balances within permit limits? Has land application equipment been calibrated? Are there pH records for alkaline stabilization? Are there pH records for the land application site? Are nutrient/crop removal practices in place? Do lab sheets support data reported on Residual Analysis Summary? Are hauling records available? Are hauling records maintained and up-to-date? # Has permittee been free of public complaints in last 12 months? Has application occurred during Seasonal Restriction window? Class A product distributed for use as a soil amendment. Hazardous waste characterization is required once per permit cycle. Comment: Pathogen and Vector Attraction Yes No NA NE a. Fecal coliform SM 9221 E (Class A or B) Class A, all test must be <1000 MPN/dry gram Geometric mean of 7 samples per monitoring period for class B<2.0*10E6 CFU/dry gram Fecal coliform SM 9222 D (Class B only) Geometric mean of 7 samples per monitoring period for class B<2.0*10E6 CFU/dry gram b. pH records for alkaline stabilization (Class A) c. pH records for alkaline stabilization (Class B) Temperature corrected Page 3 of 4 DocuSign Envelope ID: D64F4551-9DE4-472E-B391-E0B60D20CA47 Inspection Date: Permit: Inspection Type : Owner - Facility: Reason for Visit: WQ0010689 04/26/2022 Annual Report Review Baxter Healthcare Corporation Routine d. Salmonella (Class A, all test must be < 3MPN/4 gram day) e. Time/Temp on: Digester (MCRT) Compost Class A lime stabilization f. Volatile Solids Calculations g. Bench-top Aerobic/Anaerobic digestion results Boiler ash residual. Does not meet definition of biological residual.Comment: Treatment Yes No NA NE Check all that apply Aerobic Digestion Anaerobic Digestion Alkaline Pasteurization (Class A) Alkaline Stabilization (Class B) Compost Drying Beds Other See above.Comment: Page 4 of 4 DocuSign Envelope ID: D64F4551-9DE4-472E-B391-E0B60D20CA47