HomeMy WebLinkAboutNC0063321_Renewal Application_20220221TUCKASEIGEE WATER &SEWER AUTHORITY
SERVING JACKSON COUNTY
1246 West Main Street
Sylva, NC 28779
Phone:(828)586-5189 • Fax:(828)631-9089
Feb 21,2022
NCDENR/DWR
NPDES Unit
1617 Mail Service Center
Raleigh NC 27699-1617
Subject: Permit Renewal, TWSA Plant#3 (Cashiers WWTP)
NC0063321)
Tuckaseigee Water and Sewer Auth
Jackson County
Attn:NPDES Unit
With this letter and completed application,the Tuckaseigee Water and Sewer Authority
requests renewal of our NPDES Permit#NC 0063321,for the TWSA Plant#3 facility.
I have attached the original and two copies of the Permit Renewal.
Please contact me with any questions or comments. I can be reached directly at 828-586-
9318 or email at @sbrson twsanc.us .Y
Sincerely,
Stan Bryson
Wastewater Plant Operations Supt.
RECEIVEDTuckaseigeeWaterandSewerAuth.
FEB 25 2022
NCDEQ/DWR/NPDES
xc: Mr. Daniel Manring,Executive Director,
Tuckaseigee Water and Sewer Authority
This institution is an equal opportunity provider and employer.
FACILITY NAME AND PERMIT NUMBER: PERMIT ACTION REQUESTED: RIVER BASIN:
TWSA Plant#3, NC0063321 Renewal Savannah
FORM
2A NPDES FORM 2A APPLICATION OVERVIEW
NPDES
APPLICATION OVERVIEW
Form 2A has been developed in a modular format and consists of a "Basic Application Information" packet
and a"Supplemental Application Information" packet. The Basic Application Information packet is divided
into two parts. All applicants must complete Parts A and C. Applicants with a design flow greater than or
equal to 0.1 mgd must also complete Part B. Some applicants must also complete the Supplemental
Application Information packet. The following items explain which parts of Form 2A you must complete.
BASIC APPLICATION INFORMATION:
A. Basic Application Information for all Applicants. All applicants must complete questions A.1 through A.8. A treatment works
that discharges effluent to surface waters of the United States must also answer questions A.9 through A.12.
B. Additional Application Information for Applicants with a Design Flow 0.1 mgd. All treatment works that have design flows
greater than or equal to 0.1 million gallons per day must complete questions B.1 through B.6.
C. Certification. All applicants must complete Part C(Certification).
SUPPLEMENTAL APPLICATION INFORMATION:
D. Expanded Effluent Testing Data. A treatment works that discharges effluent to surface waters of the United States and meets
one or more of the following criteria must complete Part D(Expanded Effluent Testing Data):
1. Has a design flow rate greater than or equal to 1 mgd,
2. Is required to have a pretreatment program(or has one in place), or
3. Is otherwise required by the permitting authority to provide the information.
E. Toxicity Testing Data. A treatment works that meets one or more of the following criteria must complete Part E(Toxicity Testing
Data):
1. Has a design flow rate greater than or equal to 1 mgd,
2. Is required to have a pretreatment program(or has one in place), or
3. Is otherwise required by the permitting authority to submit results of toxicity testing.
F. Industrial User Discharges and RCRA/CERCLA Wastes. A treatment works that accepts process wastewater from any
significant industrial users(SIUs)or receives RCRA or CERCI.A wastes must complete Part F(Industrial User Discharges
and RCRA/CERCLA Wastes). SIUs are defined as:
1. All industrial users subject to Categorical Pretreatment Standards under 40 Code of Federal Regulations(CFR)403.6 and
40 CFR Chapter I, Subchapter N(see instructions); and
2. Any other industrial user that:
a. Discharges an average of 25,000 gallons per day or more of process wastewater to the treatment works(with certain
exclusions); or
b. Contributes a process wastestream that makes up 5 percent or more of the average dry weather hydraulic or organic
capacity of the treatment plant;or
c. Is designated as an SIU by the control authority.
G. Combined Sewer Systems. A treatment works that has a combined sewer system must complete Part G(Combined Sewer
Systems).
ALL APPLICANTS MUST COMPLETE PART C (CERTIFICATION)
EPA Form 3510-2A(Rev.1-99). Replaces EPA forms 7550-6&7550-22. Page 1 of 22
TUCKASEIGEE WATER &SEWER AUTHORITY
SERVING JACKSON COUNTY
1246 West Main Street
Sylva, NC 28779
Phone:(828)586-5189 o Fax: (828)631-9089
Feb 21, 2022
NCDENR/DWR
NPDES Unit
1617 Mail Service Center
Raleigh NC 27699-1617
Subject:Permit Renewal, TWSA Plant#3 (Cashiers WWTP)
NC0063321)
Tuckaseigee Water and Sewer Auth --
Jackson County
Attn:NPDES Unit
With this letter and completed application,the Tuckaseigee Water and Sewer Authority
requests renewal of our NPDES Permit#NC 0063321, for the TWSA Plant#3 facility.
I have attached the original and two copies of the Permit Renewal.
Please contact me with any questions or comments. I can be reached directly at 828-586-
9318 or email at sbryson@twsanc.us
Sincerely,
Stan Bryson
Wastewater Plant Operations Supt.
Tuckaseigee Water and Sewer Auth.
xc: Mr. Daniel Manring,Executive Director,
Tuckaseigee Water and Sewer Authority
This institution is an equal opportunity provider and employer.
FACIUTY NAME AND PERMIT NUMBER: PERMIT ACTION REQUESTED: RIVER BASIN:
TVVSA Plant#3, NC0063321 Renewal Savannah
FORM
armsi.:+#+r^'s.xz-ns-•,. ....air ve'-Ix»s3'.>. e.-za t^Y3.a.i'" s.'r y.:
2A NPDES F VID2-A A PP LIC—MION 01/ER1'/IEW 4 w`'"
edt.'w.i-"-NPDES 1 it g
APPLICATION OVERVIEW
Form 2A has been developed in a modular format and consists of a "Basic Application Information" packet
and a"Supplemental Application Information" packet. The Basic Application Information packet is divided
into two parts. All applicants must complete Parts A and C. Applicants with a design flow greater than or
equal to 0.1 mgd must also complete Part B. Some applicants must also complete the Supplemental
Application Information packet. The following items explain which parts of Form 2A you must complete.
BASIC APPLICATION INFORMATION:
A. Basic Application Information for all Applicants. All applicants must complete questions A.1 through A.8. A treatment works
that discharges effluent to surface waters of the United States must also answer questions A.9 through A.12.
B. Additional Application Information for Applicants with a Design Flow z 0.1 mgd. All treatment works that have design flows
greater than or equal to 0.1 million gallons per day must complete questions B.1 through B.6.
C. Certification. All applicants must complete Part C(Certification).
SUPPLEMENTAL APPLICATION INFORMATION:
D. Expanded Effluent Testing Data. A treatment works that discharges effluent to surface waters of the United States and meets
one or more of the following criteria must complete Part D(Expanded Effluent Testing Data):
1. Has a design flow rate greater than or equal to 1mgd,
2. Is required to have a pretreatment program(or has one in place),or
3. Is otherwise required by the permitting authority to provide the information.
E. Toxicity Testing Data. A treatment works that meets one or more of the following criteria must complete Part E(Toxicity Testing
Data):
1. Has a design flow rate greater than or equal to 1 mgd,
2. Is required to have a pretreatment program(or has one in place),or
3. Is otherwise required by the permitting authority to submit results of toxicity testing.
F. Industrial User Discharges and RCRA/CERCLA Wastes. A treatment works that accepts process wastewater from any
significant industrial users(Sills)or receives RCRA or CERCLA wastes must complete Part F(Industrial User Discharges
and RCRA/CERCLA Wastes). Sills are defined as:
1. All industrial users subject to Categorical Pretreatment Standards under 40 Code of Federal Regulations(CFR)403.6 and
40 CFR Chapter I,Subchapter N(see instructions);and
2. Any other industrial user that:
a. Discharges an average of 25,000 gallons per day or more of process wastewater to the treatment works(with certain
exclusions);or
b. Contributes a process wastestream that makes up 5 percent or more of the average dry weather hydraulic or organic
capacity of the treatment plant;or
c. Is designated as an SIU by the control authority.
G. Combined Sewer Systems. A treatment works that has a combined sewer system must complete Part G(Combined Sewer
Systems).
7%.> aYFI
r
A AP..P KTES M SNSO PA C(C T,lE1 ON
Sl
EPA Form 3510-2A(Rev.1-99). Replaces EPA forms 7550-6&7550-22. Page 1 of 22
FACILITY NAME AND PERMIT NUMBER: PERMIT ACTION REQUESTED: RIVER BASIN:
TWSA Plant#3,, NC0063321 Renewal•" -.
I"'- `r"—y..:.. .,'4.`',s
Sa
r.
v annah
m41 :40w irvi :PXW-MrR h f;
BgSICagPPLICATIONINFO ATION rY
PART,A BASIC\PPLCi4T10N'INFfORMi4TtOf IiFORA LL'Ap 'w',fT' ` y}5
r
Y3n "" 'p''p
c:..r.Y^.*Jh a:is x3'_:.@5''.'i'_..__.._1'_..r r?c'-±rr,
n fMT"P\'.MIt.S;''gew "rna• L.IS .YZ'`
f.
7` _" .!t...y- { -,!.
All treatment works must complete questions A.1 through A.8 of this Basic Application Information Packet
A.1. Facility Information.
Facility Name TWSA Plant#3
Mailing Address 1246 West Main St.
Sylva,NC 28779
Contact Person Stan Bryson
Title Wastewater Plant Operations Superintendent
Telephone Number 828)586-9318
Facility Address 851 Cashiers Lake Rd.
not P.O.Box) Cashiers NC 28717
A.2. Applicant Information. If the applicant is different from the above,provide the following:
Applicant Name Tuckaseigee Water&Sewer Authority
Mailing Address Same as above
Contact Person Same as above
Title
Telephone Number
Is the applicant the owner or operator(or both)of the treatment works?
X owner X operator
Indicate whether correspondence regarding this permit should be directed to the facility or the applicant.
facility X applicant
A.3. Existing Environmental Permits. Provide the permit number of anyexistingenvironmentalpermits that have beenee issued to the
include state-issued permits).
treatment works
NPDES NC 0063321 PSD
UIC Other
RCRA Other
A.4. Collection System Information. Provide information on municipalities and areas served by the facility. Provide the name and population of each
entity and,if known,provide information on the type of collection system(combined vs.separate)and its ownership(municipal,private,etc.).
Name Population Served Type of Collection System Ownership
Tuckaseigee Water&Sewer Auth. 1100 Separate Municipal
Total population served 1100
EPA Form 3510-2A(Rev.1-99). Replaces EPA forms 7550-6&7550-22. Page 2 of 22
FACILITY NAME AND PERMIT NUMBER: PERMIT ACTION REQUESTED: RIVER BASIN:
TWSA Plant#3, NC0063321 Renewal Savannah
A.5. Indian Country.
a. Is the treatment works located in Indian Country?
Yes X No
b. Does the treatment works discharge to a receiving water that is either in Indian Country or that is upstream from(and eventually flows
through)Indian Country?
Yes X No
A.6. Flow. Indicate the design flow rate of the treatment plant(i.e..the wastewater flow rate that the plant was built to handle). Also provide the
average daily flow rate and maximum daily flow rate for each of the last three years. Each year's data must be based on a 12-month time period
with the 121°month of This year"occurring no more than three months prior to this application submittal.
a. Design flow rate 0.200 mgd
Two Years Aqo Last Year This Year
b. Annual average daily flow rate 0.083 mqd (2019) 0.094 mqd (2020) 0.090mqd (2021)
c. Maximum daily flow rate 0.184 mqd (4/27) 0.213 mqd (10/29) 0.267 mqd (10/07)
A.7. Collection System. Indicate the type(s)of collection system(s)used by the treatment plant. Check all that apply. Also estimate the percent
contribution(by miles)of each.
X Separate sanitary sewer 100
Combined storm and sanitary sewer
u
A.8. Discharges and Other Disposal Methods.
a. Does the treatment works discharge effluent to waters of the U.S.? X Yes No
If yes,list how many of each of the following types of discharge points the treatment works uses:
i. Discharges of treated effluent one
ii. Discharges of untreated or partially treated effluent 0-
iii. Combined sewer overflow points 0-
iv. Constructed emergency overflows(prior to the headworks) 0-
v. Other 0-
b. Does the treatment works discharge effluent to basins,ponds,or other surface impoundments
that do not have outlets for discharge to waters of the U.S.?Yes X No
If yes,provide the following for each surface impoundment
Location:
Annual average daily volume discharge to surface impoundment(s) mgd
Is discharge continuous or intermittent?
c. Does the treatment works land-apply treated wastewater? Yes X No
If yes,provide the following for each land application site:
Location:
Number of acres:
Annual average daily volume applied to site:mgd
Is land application continuous or intermittent?
d. Does the treatment works discharge or transport treated or untreated wastewater to another
treatment works? X Yes No
EPA Form 3510-2A(Rev.1-99). Replaces EPA forms 7550-6&7550-22. Page 3 of 22
FACILITY NAME AND PERMIT NUMBER: PERMIT ACTION REQUESTED: RIVER BASIN:
TWSA Plant#3, NC0063321 Renewal Savannah
If yes,describe the mean(s)by which the wastewater from the treatment works is discharged or transported to the other treatment works
e.g.,tank truck,pipe).
Diqestor sludge is hauled via tank truck to TWSA Plant#1 for treatment and disposal.
If transport is by a party other than the applicant,provide:
Transporter Name Coopers Septic Service
Mailing Address 366 Fern Trail
Waynesville NC 28786
Contact Person Manual Cooper
Title Owner
Telephone Number (828)734-2403
For each treatment works that receives this discharge,provide the following:
Name TWSA Plant#1
Mailing Address 1246 W.Main St.
Svlva NC 28779
Contact Person Stan Bryson
Title Wastewater Plant Operations Supt.
Telephone Number (828)586-9318
If known,provide the NPDES permit number of the treatment works that receives this discharge NC 0039578
Provide the average daily flow rate from the treatment works into the receiving facility. .00025 mgd
e. Does the treatment works discharge or dispose of its wastewater in a manner not included
in A.8.through A.8.d above(e.g.,underground percolation,well injection): Yes X No
If yes,provide the following for each disposal method:
Description of method(including location and size of site(s)if applicable):
Annual daily volume disposed by this method:
Is disposal through this method continuous or intermittent?
EPA Form 3510-2A(Rev.1-99). Replaces EPA forms 7550-6&7550-22. Page 4 of 22
FACILITY NAME AND PERMIT NUMBER: PERMIT ACTION REQUESTED: RIVER BASIN:
TWSA Plant#3, NC0063321 Renewal Savannah
WASTEWATER DISCHARGES:
If you answered"Yes"to question A.8.a,complete questions A.9 through A.12 once for each outfall(including bypass points)through
which effluent is discharged. Do not include Information on combined sewer overflows in this section. If you answered"No"to questionA.B.a,go to Part B."Additional Application Information for Applicants with a Design Flow Greater than or Equal to 0.1 mgd."
A.9. Description of Outfall.
a. DutfaII number 001
b. Location Cashiers 28717
City or town,if applicable) Zip Code)
Jackson NC
County) State)
35°6'12" 83°6'28"
Latitude)Longitude)
c. Distance from shore(if applicable) ft.
d. Depth below surface(if applicable) ft.
e. Average daily flow rate 2021) 0.090 mgd
f. Does this outfall have either an intermittent or a periodic discharge? Yes X No (go to A.9.g.)
If yes,provide the following information:
Number f times per year discharge occurs:
Average duration of each discharge:
Average flow per discharge: mgd
Months in which discharge occurs:
g. Is outfall equipped with a diffuser? X Yes No
A.10. Description of Receiving Waters.
a. Name of receiving water Unamed tributary to the Chatooqa River
b. Name of watershed(if known) Chatooqa River Watershed
United States Soil Conservation Service 14-digit watershed code(if known): 03060102010010
c. Name of State Management/River Basin(if known):Savannah
United States Geological Survey 8-digit hydrologic cataloging unit code(if known): 03060101
d. Critical low flow of receiving stream(if applicable)
acute cfs chronic cfs
e. Total hardness of receiving stream at critical low flow(if applicable): mg/I of CaCO3
EPA Form 3510-2A(Rev.1-99). Replaces EPA forms 7550-6&7550-22. Page 5 of 22
FACILITY NAME AND PERMIT NUMBER: PERMIT ACTION REQUESTED: RIVER BASIN:
TWSA Plant#3, NC0063321 Renewal Savannah
A.11. Description of Treatment
a. What level of treatment are provided? Check all that apply.
X Primary X Secondary
Advanced X Other. Describe: Tertiary Filters
b. Indicate the following removal rates(as applicable):
Design BOD5 removal or Design CBOD5 removal Info not available
Design SS removal
Design P removal
Design N removal
Other
c. What type of disinfection is used for the effluent from this outfall? If disinfection varies by season,please describe:
Chlorination
If disinfection is by chlorination is dechlorination used for this outfall? X Yes No
Does the treatment plant have post aeration? X Yes No
A.12. Effluent Testing Information. All Applicants that discharge to waters of the US must provide effluent testing data for the following
parameters. Provide the indicated effluent testing required by the permitting authority for each outfall through which effluent is
discharged. Do not include information on combined sewer overflows In this section. All information reported must be based on data
collected through analysis conducted using 40 CFR Part 136 methods. In addition,this data must comply with QAIQC requirements of
40 CFR Part 136 and other appropriate QAIQC requirements for standard methods for analytes not addressed by 40 CFR Part 136. At a
minimum,effluent testing data must be based on at least three samples and must be no more than four and one-half years apart
Outfall number. 001
MAXIMUM DAILY VALUE AVERAGE DAILY VALUE
PARAMETER
Value Units Value Units Number of Samples
pH(Minimum) 6.0 s.u.
pH(Maximum) 6.6 s.u.
Flow Rate 267 mgd 090 mgd 365
Temperature(Winter) 15.6 C 11.3 C 100
Temperature(Summer) 23.4 C 19.3 C 146
For pH please report a minimum and a maximum daily value
MAXIMUM DAILY AVERAGE DAILY DISCHARGE
POLLUTANT
DISCHARGE ANALYTICAL
Conc. Units Conc. Units
Number of METHOD MLIMDL.
Samples
CONVENTIONAL AND NON CONVENTIONAL COMPOUNDS
BIOCHEMICAL OXYGEN
BOD5 22.2 mg/I 5.2 mg/I 52 SM 5210-B 2.0 mg/I
DEMAND(Report one)
CBOD5
FECALCOLIFORM 61 cfu/100 ml 5
cfu I00 52 SM 9222-D lcfu/100 ml
Total Suspended Solids
TSS) 28.6 mg/I 7 mg/I 53 SM 2540-D 2.5 mg/I
i . . z
a
1 a
yki, ENE/Q PARTA S .
5z.rri ;
REF R TOOTHE AP ,LICA-TI tayERVIEVV(PA )`TO"`D , .ERMINE WHICH'0THER1P`ARTS x
sF` d ..-. . ,x-.1t' ,,tirtS .2:::vs ±' tte.,. +-ke'ST .:-.''a- .r.at4N. s ^:gt-I QZ".'.r-`a''w.&L''` Ar-a. jf:cX):^v ?yq. ';.k i:u't
EPA Form 3510-2A(Rev.1-99). Replaces EPA forms 7550-6&7550-22. Page 6 of 22
FACILITY NAME AND PERMIT NUMBER: PERMIT ACTION REQUESTED: RIVER BASIN:
TWSA Plant#3, NC0063321 Renewal Savannah
BASIC APPLICA`OON 1NEORMATION , - `. , w_ A s4,s--
3.' afi«...sr- .5 • 5. "`... =
u
s6 +.=',,,: ta,i:'r':. s,alcl^'.t.t•"33T,°'?
ri...`.C.S{?.7"
1 T K...s?E' Y.`:' "r ". -r .fse ro va.
40TB= DIttJIJAL ASP ',.ORM ON 011PPL1(v—.•e ESlGN1t=-..,, REA'-; •', HA „EG2UAAL 001"MD,100 600.- a I -''''Ypel'Pr clay k2 e'z. _'
t
3.._':,:,-,T A. < z wz. —M _ _ 'iia' Zs..7 v 4S? k5`, - .x.£ {`,
i, sa,., :: ^ St
All applicants with a design flow rate 2 0.1 mgd must answer questions B.1 through B.6. All others go to Part C(Certification).
B.1. Inflow and Infiltration. Estimate the average number of gallons per day that flow into the treatment works from inflow and/or infiltration.
5000 qpd gpd
Briefly explain any steps underway or planned to minimize inflow and infiltration.
Ongoing preventive maintenance program by TWSA collection system staff.
B.2. Topographic Map. Attach to this application a topographic map of the area extending at least one mile beyond facility property boundaries. This
map must show the outline of the facility and the following information. (You may submit more than one map if one map does not show the entire
area.)
a. The area surrounding the treatment plant,including all unit processes.
b. The major pipes or other structures through which wastewater enters the treatment works and the pipes or other structures through which
treated wastewater is discharged from the treatment plant. Include outfalls from bypass piping,if applicable.
c. Each well where wastewater from the treatment plant is injected underground.
d. Wells,springs,other surface water bodies,and drinking water wells that are: 1)within''%mile of the property boundaries of the treatment
works,and 2)listed in public record or otherwise known to the applicant.
e. Any areas where the sewage sludge produced by the treatment works is stored,treated,or disposed.
f. If the treatment works receives waste that is classified as hazardous under the Resource Conservation and Recovery Act(RCRA)by truck,rail,
or special pipe,show on the map where the hazardous waste enters the treatment works and where it is treated,stored,and/or disposed.
B.3. Process Flow Diagram or Schematic. Provide a diagram showing the processes of the treatment plant,including all bypass piping and all
backup power sources or redundancy in the system. Also provide a water balance showing all treatment units,including disinfection(e.g.,
chlorination and dechlorination). The water balance must show daily average flow rates at influent and discharge points and approximate daily flow
rates between treatment units. Include a brief narrative description of the diagram.
B.4. OperationlMaintenance Performed by Contractor(s).
Are any operational or maintenance aspects(related to wastewater treatment and effluent quality)of the treatment works the responsibility of a
contractor? Yes X No
If yes,list the name,address,telephone number,and status of each contractor and describe the contractor's responsibilities(attach additional
pages if necessary).
Name:
Mailing Address:
Telephone Number_
Responsibilities of Contractor.
B.5. Scheduled improvements and Schedules of Implementation. Provide information on any uncompleted implementation schedule or
uncompleted plans for improvements that will affect the wastewater treatment,effluent quality,or design capacity of the treatment works. If the
treatment works has several different implementation schedules or is planning several improvements,submit separate responses to question B.5
for each. (If none,go to question B.6.)
a. List the outfall number(assigned in question A.9)for each outfall that is covered by this implementation schedule.
No scheduled improvements at this time
b. Indicate whether the planned improvements or implementation schedule are required by local,State,or Federal agencies.
Yes No
EPA Form 3510-2A(Rev.1-99). Replaces EPA forms 7550-6&7550-22. Page 7 of 22
FACILITY NAME AND PERMIT NUMBER: PERMIT ACTION REQUESTED: RIVER BASIN:
TWSA Plant#3, NC0063321 Renewal Savannah
c. If the answer to B.5.b is"Yes,"briefly describe,including new maximum daily inflow rate(if applicable).
d. Provide dates imposed by any compliance schedule or any actual dates of completion for the implementation steps listed below,as
applicable. For improvements planned independently of local,State,or Federal agencies,indicate planned or actual completion dates,as
applicable. Indicate dates as accurately as possible.
Schedule Actual Completion
Implementation Stage MM/DD/YYYY MM/DD/YYYY
Begin Construction
End Construction
Begin Discharge
Attain Operational Level
e. Have appropriate permits/clearances concerning other Federal/State requirements been obtained? 0 Yes 0 No
Describe briefly:
B.6. EFFLUENT TESTING DATA(GREATER THAN 0.1 MGD ONLY).
Applicants that discharge to waters of the US must provide effluent testing data for the following parameters. Provide the indicated
effluent testing required by the permitting authority for each outfall through which effluent is discharged. Do not include information
on combine sewer overflows in this section. AU Information reported must be based on data collected through analysis conducted
using 40 CFR Part 136 methods. In addition,this data must comply with QA/QC requirements of 40 CFR Part 136 and other appropriate
QA/QC requirements for standard methods for analytes not addressed by 40 CFR Part 136. At a minimum effluent testing data must be
based on at least three pollutant scans and must be no more than four and on-half years old.
Outfall Number. 001
MAXIMUM DAILY
AVERAGE DAILY DISCHARGEDISCHARGE
ANALYTICALPOLLUTANT L/
METHOD MMDL
Conc. Units Conc. Units Number of
Samples
CONVENTIONAL AND NON CONVENTIONAL COMPOUNDS
AMMONIA(as N) 1.8 mg/I 0.6 mg/I 52 SM 4500 NH'-C 0.5 mg/I
CHLORINE(TOTAL
20 u /1 20 u /I I104SM4500CI-G 20 uRESIDUAL,TRC) g g 9
DISSOLVED OXYGEN 11.4 mgll 9.0 mg/I 52 SM 4500-OG 1.0 mg/I
TOTAL KJELDAHL
4.1 mg/I 3.1 mg/1 4 EPA 351.2 0.50 mg/INITROGEN(TKN)
NITRATE
g
NI OGENLUS NITRITE
18.3 mg/I 14.6 mg/I 4 EPA 353.2 0.10 mg/I
OIL and GREASE
PHOSPHORUS(Total) 2.9 mg/I 2.2 mg/I 4 EPA 365.1 050 mg.I
TOTAL DISSOLVED SOLIDS
TDS)
OTHER
i ',F."T'_ '",{ is a etk7#l ,9",..r.- „r- µ. - .a x c
S r;}w^tt,' Y cn r N r K 7 ` i-F'tit
I,
u ' E o taFFP TSB ;^- 11.4: ':6'6: ee G
RPLICATION1 o VE`
r
n ' 'REEM _Yimt. . -:. ?-.
i
s'°`. *'L'
r y,;er F`.?..s. ,:_r;: ``
EPA Form 3510-2A(Rev.1-99). Replaces EPA forms 7550-6&7550-22. Page 8 of 22
1
FACILITY NAME AND PERMIT NUMBER: PERMIT ACTION REQUESTED: RIVER BASIN:
TWSA Plant#3, NC 0063321 Renewal Savannah
v1u
BA`SIC APPLICATIONJNEORMATION R '`. :
a `' .• :• '
sum
3:^rjw*9h:• ,awa-Ysr S'^1 rr>i s , Y Y:"d'•APART C:W CERTIFICATION- z
s
w
Y
5.,..
r.... <_,,:w...,r.'..5!.s-
Y.k:- bru. ._.> T.,...c ...,a4 y
All applicants must complete the Certification Section. Refer to instructions to determine who is an officer for the purposes of this
certification. All applicants must complete all applicable sections of Form 2A,as explained in the Application Overview. Indicate below which
parts of Form 2A you have completed and are submitting. By signing this certification statement,applicants confirm that they have reviewed
Form 2A and have completed all sections that apply to the facility for which this application is submitted.
Indicate which parts of Form 2A you have completed and are submitting:
X Basic Application Information packet Supplemental Application Information packet:
Part D(Expanded Effluent Testing Data)
Part E(Toxicity Testing: Biomonitoring Data)
Part F(Industrial User Discharges and RCRA/CERCLA Wastes)
Part G(Combined Sewer Systems)
2;11,1 vP.'.:' {`x' ` ue474 WaV 7r 3
rh-.:.-..,f:.cc<_,;;•:.%rr.r as,._ ... v'o z 'y,<r,`+
ai.i id':
I certify under penalty of law that this document and all attachments were prepared under my direction or supervision in accordance with a system
designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who
manage the system or those persons directly responsible for gathering the information,the information is,to the best of my knowledge and belief,true,
accurate,and complete. I am aware that there are significant penalties for submitting false information,including the possibility of fine and imprisonment
for knowing violations.
Name and official title Stan WWTP Operations Supt.
Signature
Telephone number (828)586-9318
Date signed 2/21/22
Upon request of the permitting authority,you must submit any other information nerpcsary to assure wastewater treatment practices at the treatment
works or identify appropriate permitting requirements.
SEND COMPLETED FORMS TO:
NCDENRI DWR
Attn: NPDES Unit
1617 Mail Service Center
Raleigh, North Carolina 27699-1617
EPA Form 3510-2A(Rev.1-99). Replaces EPA forms 7550-6&7550-22. Page 9 of 22
TWSA Plant #3 WWTP
NC 0063321)
Sludge Management Plan
The sludge generated in the activated sludge process at the facility will
be stored in the aerobic digestor (capacity 56,000 gals) before being
hauled via tank truck to the Tuckaseigee Water and Sewer Authority's
sludge handling facility located at: TWSA Plant #1
1871 North River Rd.
Sylva NC 28779
The sludge from the tank truck will be dumped into one of two aerobic
digestors at the TWSA Plant #1 facility. A sample of the sludge will be
obtained from the tanker on each day that a hauling event occurs. This
sampling allows calculation of the total tons of residuals hauled from
the TWSA Plant #3 WWTP. After being mixed and stabilized via air from
diffusers installed in the digestor, the sludge is dewatered via the 1.2
meter Komline-Sanderson belt press. Dewatered sludge is then
disposed of by either hauling to a designated landfill or by being treated
to a Class A Residual in the rotary batch dryer as manufactured by
Fenton Environmental Technologies. Treated residuals are then
disposed of under the authority of non-discharge permit # WQ0005763
as issued by NC Dept of Environment and Natural Resources.
02:7-,- ,7.-7, -,, -,•,..,•,, — -,,7 -,,,r.7 .,7-7:-.1 rer::,- ,X0',i-•17-voia6P-'7.-47.,,,2f:',...\7,`.'5:17% -•:1•01F'0'-':-..7;.:.
crL r r
c
E y
z
l : 8 t/
r, w
1go5 a ,t
l`hR: "z
r•?,•;
zl' :r' . 1 Cr" re: it ` `
y1f .{
L
R•R 1rS J h SS.aT"!y r
Jl1+f
t Y [ 6t. 1
P 6-s ° t
C
t 1 '¢ t R.-'
1r ;. :J n.i ?i. *ly,; t1.._r.
d t )l/
1
Y -
rt -, Chattooga River
1 z flows SE) Si` Ati '..
AgaYi 4F
ti :,,, `y+!• r" R cJ ; :, i fit. 8,, • /j .- .
ir rw "
a'v , r -,
F,-'k r \ • eer—„,. .n4z.,-'.FiZ+r.6.e 7- t _
l rt `-vre. Lv"
1-
ll 1-1,!
zi - }.
y •
i. •ts' -' C''-
t
t I wC ("f-4i A Teri?'
r ' ;V.9)
g.- •[,,!,z '4 L•,":y, +
I
t '
li .
l .1 r\.r.
t :S 4^ :'.t"S'ax .' j h}Sr::4 $ a'"'}` 1 ' :
r
by rr =g h'
C's '*1•s \ , • *
1•..
y 1 +4Jh'.m'y
4.•
E,.
j 1a
r s'' -• !.i;,, a t,x
i a^'a,
try 4 [ .
5.- .. ,
Y. ,,0:
t•,,
r,r c_at S "h ` ,FA,y.,tGl..i r . ?` ...,;r .'' '' 7,4
ayS r..y«
A,
3
c'
r k ^' 1 ocW x ryay.r.« r:
a° ,,,
t..;f+g t of r >•nry k .'!' "-
n , .\ o ir bra is t .
Cf' r
x4. r y a d ly t'tsa } - y .r A fa - M
J Sy, if It,„..^'`;; ?y + 7 t t . y:+7e. I. ' t E aYl e'K jy, ,,4- ,',' r?,
p ` _: • , r.,..e 1,
a, _ :-
P: i. ., -- 'og „L4- esf't!ig h1r7
v /
1 ',aa .mot r ,.,,i ''
4
v '1 . +? htk C.,`, 4,
r•
e.
4, k , r {
5t i33i,,/J '+''-~`{'1 r ;to t •
1 4. F.•
r -, / S fy 1 r i x %.-
r.
3;,
arc It t ;.3 x sk '.
J
5.% •r...
r
b
r.,1 t a. ,!f 'w. -
r
f
4.krx `
4' .f } -`
1 y .r 54,1 '
r-..t.%f7- r va i "f'ti x / Y •f.,i,
t./ ea. r u5""
i
j:
rt' .
y rw ti e:.x..s'i:i l `' _a t.
M
e4N +?v.
4sr - __Sth r:r..1 ..
Qi K- e:
ek E ti F c .:a .li•Y3. i•
3} ,ra ;
I
r
n LWTj j6 ' a • _'34 I NCH 64' A •
s r
fit 3Kzfcs
w
10146% .
r.i.-c: • •,
a.'r
a
1,:`4 .. i h r aVl dz • S ,
34
s Y 3 i
7 tsv p ti
1,` ,.r-(; _
a4 :/g t'3a 'L(* ifs,.
I.
r4j.. •r4 V -2r7`` .ya a ..C 5 Yr' t
v. \. _ ^d.../jjj 1 ,+r; 'ar t1 y^
ei't,s K
7. tp* t
t °'ta 41' `1<t
f'4>-1
lt,,,tom., ;.t?: rat
A Ly' t
f./
1" .g i" 4.?:a.,:I l
a ... /
k t
il
I f4'.3.- ,y,_,• c;afs ika-11,, 1i
I.
r,,s
s{;.
q GaJl,, {G
V'
3 r?,rfi s `,IS„<.
a
cti I l a saa 3 i
bc,1t `' 7ht 'v
tt t ....-..
tr•.
3 :- S.t•.S3r'M • 43 yr P S G /. fL e t i
i. „-# z Y• a r.z71 is ;,, // •'^' j -,y46:0.#/Pi 7Q '0' «oc ,>i •.
a V a f 4`r
u,` a'';t J ' i;t
a rk' „_ y .,
Yik .r.CA kq
iii.t Cashiers Lake Rd. t z =a ,,,vr dlr 'r•=
t e,
E• • ; `••• •r: •
S c•`.. l•a+•
d'i:yt¢+r
r
F See i j qa d3 "g,3
C ur y4 : i4 aF y Lf{ i •;'a
h
k `
t'`.
d '• [,
4:,- r3 •d°Xy* (.. a 1•?. # r .;ry,•,;d,J $,r Cs,
a. 15 #n1r"". "'t 4.
E, -R i4..%t 0.-r t .- V .sr lti, r r r i S•;?'f.1) a'" 1i hi i
J
I .+,r&—1 11.: ` 4 '
r
i
s ,,rA' -' .a.r.- 4"•..1c'tic. "'
a,Q3 d r''_'Z'
x : '-
F WI;op. Y ,c%! r i4y;S 3••r: i
r +xa.'- Yf. irk- ai. +.. t,',. 9'' i+ 1 .,
i.,.f'.
R 4 7:.
r ~3'M-r'liarJ?t_!L+'a a ram .X 'L 0. \' 9 vo ,1' A' .,
J
ti
a
i . '.
S StYI yY••'a i r. 7•Y 'Q'o 4' . V ` }!.
2 ,, ..
r j° yt ;Q,;,r ...,',;•. v s > k%= \+ ti i i.n .+4 v rz;.u of < a''S•` t ,•
i""
h y , tr3 A< 7 r s f. •
V
r Cam..i d . i. la
i 7 trrRC f r n. J;.;+ .,
y . rk'.: t+Fi ;.. -f a '?
j r
r' r,
i
r r {{: .b N sue. Z _^F<_' ' .` r+v 0? [tom'. zw t7; :r -6'=:
i2; }
J F ,4fe,,
1e', ^ '
ram+_L
i l`i7,'' 11 : S T::F 5..: k?ip;IV'J .r 4• .•,,,
e
7" {*.
I','tv •
t--,
ua R ate; {j='
r.r 6 •.f'l 3. a` _.
i 3• Li ,,.u..:l5.n£rl 141..1-.1 k /4 ; l ,07• ?'S`. •fix a.. y0*sfa V ':' h r3
C t"- mgt L. '{'^l'' 3 4 r r A r f'S,F'r.?, 21t.• 'Nc..q''Z' .4• .'_'v
Outfall 001 } ,` ,:aa E< ; r
t,a€, j, __
h. ti 1 i' '2`•a_f"
h .
Y' • -,
F
U},Q Y k, F2 ?:., , },,V .+
5 :
1 -
r ...• P{ . .
i r ,,,., }t h i ,'ti,z1' t}y • ,
i
loWS south N r' 1 \ • S' f h s
L• k- 0 3 r. "r&. r all'
3i'i ,;ls i -.."'k,! a k:.,"l f ti ..„. h't' ,
r. r'? 1 , '`f f 2etrYn c o 4 .; t t a
FAH i r Y gny,i ..ter,. ''-;.
w t r: a 41 ? .-. 4•...A{APProx property bound 7
L = R•4 ^'`
rr`.:, ,•. rrr 17 ary a .:zx Y`r ?
3lf^ Cx- s'!' Aigi af
r --
ftfl
L j 41;. fi'4>'kpt SALitfc. q .,,b sC„ 'ar"S sf <f
f
iii
r; y- 'u'yt;+,r•xi 1,?f
rti.l '•}" r `'''
7nr. ti .r -,,,
i .r • •• +' >= ....-r...%
r'
r'
tl
J \•• ! • .4.
x'„ '. ..} -+ t
i
t.„` !i:`.'y'
s
Fi"`.' v
r f
a
R^`r.. is ,y;
a ;.'
1,,.. 1. ..
c ",tr' i F .,0 L a i i a C•L a it t `,i'
c
t
y A r ' +1 ; y a. i
Y1 5 , -,.a.7k6b-1 „ C I f`; ..
rr -"- t
1,'n •.$;' A mo t` d f y ' '/rim"`,-,`,4.Y1 ,'
i
k.„ w %':
9.le f 7-- re. 4 S Ir/31 r 8 e •t"*Q.\ s i 4 '.ays :.t
t'.;.r,.7. r;t9!a'Y c 5
r r *!^Ctiaftooga River P • __, - r,_ sir r S s ;°' ,U ` ' _ f/ z
r iC rF Q
vuHa .1'4 Y
a, + ,rz
trtT'O 4'- "
I
4•
ir ,IA ^a ,
fir.'';"'..\,d -2 ; ; 7 f '.. '•tL i + M•c
S
iE f10. j "'
2 rr'f.,'; o'i" J{ t I i
1
1'
fi <
4
e r x. :'q ;
ta
4
f ! • O
j
e• '4t i r4 :.• y, r
ll
v,y-T1•+ ;
L. i/ ,j'j r ce!.. 1r-e:.+.7,a.. n....s: S { `
r.,,,,,---
f'
K`ry.. t41 to fy N
1 r•7 P:',e)a . '>. .NC Hwy 1O7 I.'^
r (
r n `
1 :yea ; d L';%/! F f ''.
a^
y'
rti
w, l r
T.
r r.t.,t. Jr N--/r`` r 'Ia ., a 'tk
3. ;1 a .,:c' . t,: r r r c zx - It ' ti tr ,d{f) ` 1n4l-,t'
a'`` Ys} \ : }} .;a S- c 4`I;+t; s+,..z. ., . •npr •C. rl t Fcy>„
Fa ''1.5 r.W t
y 1a S .,,Ff a _ a Y . '.'. '" +xt.t 1 •{
Rft.+.y., 1 J. / :.:'
F''=_ .
i`1k t .
4.
f 4'"
k sv Ff^t a' }
a •, ,Q?,..
tk'
r k=jf, f tr?..
1.r.ii.eax : ,r.. ,a}_
l { h ,•
atsl :`
t r I ;
T< r r• a y f 33i.s.r.'' a w-+:... ,s 4: ..` %!h '«d.a f:;ta!`"_,..k>ae ,.L/ f r— ..dr,ti'-.
Gravity Lines- tR, Pump Stations- EM Force Main- - — - _
Tuckasei ee Waterand Sewer Authority FacilityCashiers #3 WWTP
Location ;
Receiving Stream: Chattooga River Map not to scaleLatitude: 35°06'II" N State Grid/Quad: G6SE/Cashiers,NC V
Longitude: 83°06'25" W River Basin: Savannah
Stream Class: B;Trout;ORW Sub-Basin: 03-13-0I NPDES NC0063321StreamSegment: 3 HUC: 03060102 North Jackson County
I I
C .
D kor
5 ,o00 l
Ps I DIP
rsr MOST w i
AERATION Si'......''''''''N\
TCP O ° v I
1W,00D 61V
w
I
34ft r_—
1: PUMP STATION/ YY 1
CHLORINE
EXIST I/3•SCH 40 uaa. ,u.e . ?IA 9'/
PVC DECHLOR UNE
Jia s:
EirPS1IDSifilk,/limn
Eb]L EXIST }0 F I-
1 EXIST 1%2 PVC .HYDRANT • :r + ,.
g I -','i CONDUR W/COMMUNICAl10N5 Y
S
CABLE v g
f NI 1 aJ A /^eoAll(Al d _1
i w n• W, 104,000 CAL
1 /
Ram 2 / P' s a a a s Iaa sl
2
L BA
W.W. BASIN
INV=3427.4
k7yA.---,...4
p .
op_
A__„ EAST 2'SCH 40 dye f
1
A. A PVC AIR UNE 0lP1e9 :.
I; • OILOR1NAlICt7 ACi• Eq
10i 000 GAL '.:.. 4. 1..
Rom :
ir
WAIJZAl10
1 TANK
j L 78.700 GAL
tiff' '1312
obiin
0 i
T.O.W= 3456.57. T.O.W F 3456.5s-1-rt• 1.!' ,L. 1S-0.1“tt't TO CLARIFIER V:_,...., ••AYATER.LEVEL. .345541.11 V 7 - Trv• "A v• 3••=-3455:6•0170'ww • I; ; 6 IYAMI'LEVEL= 3455
AVG.WATER . z =3455.2 0 70 GPM)ei
1...
P co j \-.It.to 1 .. U
PU1AP SUCTION UNE ,,,,.
I r_ca MAX WATER LEVEL SHONW ABOVE GRADE et- S If
FOB CLARITY . c'c-* j- TO CLARIFIER)1
a .8" GRAVITY INFLUENT LINE NEW AERATION "NEw.cLARIFIER NEW AERATION CLARIFIER
1 1
3445...
NOT SHOWN) . Eriati It i 2in
104,000•GAL 104,000 GAL
a_ CHLORINE
I f;;;„____-..t r------- INV: IN.- 343130•7;1..LLi7
3440...
INV It= 34.17'00
00INV. OUT= 3436. V 4.', IVBR'LEVO.=3435.0 ; •3.435...
NEW E0 11Atit-U1s Et)-
PIPE--------7------•w4M11EXISTINGAERKRONMOST.BACK-UP WASTEWATER PUMPING STATION
ELEV. = .r"..14.27 . . Ppli%tE,-,-44-31.2.1GALNEWEXTENDEDAERATION'W/
BAN)SECONDARY CLARIFTCAMON 3431.66100,056 GAL. 80 GAL/
343o...
CLARWER)
a s
dRAvir,,LRE FROA . TERTIARY RUIRATION
BACK-UP CLARIFIER JUNCTION -
MANTIOLE V•INV.4/1 -3426.1i 4 J'Avitr 9 ma-
mtATION BAsift 7
3421,5NEWFLOWEQUALIZATION
3420..IAISTING DCIENDED--------
CONTACT DECHLOR
POST-AERA1101
ii./.BAcKup mania. ...................................................................................................... OILORINE.,.
4.375 GAL viao ca.
31.MR CONTACT d°dial ADF)10 M1CONTACT
4)OESI ADF)
CHLORINE:CONTACT/Cl)
DECHLORINATION BASINM.• • -,.. -'-: 200.000 G TREATMENT TRAIN • 1,4
o 65.
i .••:...::.
N.
fr•
c'..i••
ii