Loading...
HomeMy WebLinkAbout20060796 Ver 3_401 Application_20140922i r Corps Submittal Cover Sheet Please provide the following info: 1. Project Name Waterford of the Rocky River 2. Name of Property Owner /Applicant: Lennar Carolinas, LLC 3. Name of Consultant/Agent: Tamp Bandy *Agent authorization needs to be attached. 4. Related/Previous Action ID number(s): AID SAW- 2014 -00500 5. Site Address: 2695 Jim Johnson Rd, Concord, NC 28027 6. Subdivision Name: Waterford 7. City: Concord 8. County: Cabarrus 9. Lat: 35.45133 *N Long: -80.75311 °W 10. Quadrangle Name: Cornelius 11. Waterway: UT to Rocky River 12. Watershed: 030401050102 13. Requested Action: x Nationwide Permit # General Permit # Jurisdictional Determination Request Pre- Application Request The following information will be completed by Corps office: Prepare File Folder X19 Assign number in ORM Authorization: Section 10 Project Description/ Nature of Activity/ Project Purpose: Site/Waters Name: Keywords: ,Poo(" (Decimal Degrees Please) Section 404 Begin Date Wt4';t •S•v ji .. Wetland and Natural Resource Consultants 9/16/2014 NC DWR, Webscape Unit 1650 Mail Service Center Raleigh, NC 27699 -1650 Re- Proposed Road Crossing Impact Re- authorization Request Waterford on the Rocky River (Corps NW 14, AID #: SAW- 2014 - 00500) Cabarrus County, North Carolina To whom it may concern- The purpose of this correspondence is to request a water quality certification for a road crossing of a perennial unnamed stream to the Rocky River, which has been authorized under the,above referenced US Army Corps permit All other impacts associated with'the prior authorizations were completed Due to the recession, the largest and final crossing to access Jim Johnson Road was delayed beyond the expiration of the original authorizations. No changes have been made to the crossing with the exception of an increase in pipe diameters, and a reduction in impact length from 110 linear feet to 80 linear feet to accommodate the latest engineering design (see attached details) Please contact me if you have any questions, comments, or require additional information Sincerely, Tamp Bandy Hickory Office 1646 Machine Shop Road Hickory, NC 28602 Phone 828 -302 -3437 WH;tti Wetland,and Natural Resource Consultants = Department of the Army Wilmington District, Corps of Engineers PO Box 1890 Wilmington, North Carolina, 28402 -1890 -and- NC Division of Water Quality, WBSCPE Unit 512 North Salisbury Street Raleigh, North Carolina, 27604 Re- Agent Authorization The undersigned, registered property owners of the noted property; do hereby authorize Wetland and Natural Resource Consultants to act on my behalf and take all actions necessary for the processing of this jurisdictional verification, permit or certification request and any and all standard and special conditions attached. I /we reserve the right to accept or appeal all final, proffered actions, jurisdictional determinations, permits or certifications and any and all standard and special conditions attached. Property Owner / Applicant- C-sgs o., %PLC Contact Name- ­TZ -vAas JoiAN-.o�J Street Address / PO Box- J\�-3U (- AoAG:- FsLQD City, State, Zip Code: Phone / Fax Number X41 Z -�3f S Project Name, wAT62Fo(LQ Property Street Address" S Ni L,oH C tt(ka c% RoA,f*) Y-AtJN'hPO X15, N$o$ I (street address, city, State and zip, or County and Tax PIN) Owner / Applicant Signature - Date. 2 'Icy l Hickory Office 1646 Machine Shop Road Hickory,' NC 28602 W AT ��OF fcq >b� o Office Use Only: Corps action ID no. DWQ project no. Form Version 1.4 January 2009 Page 1 of 10 PCN Form - Version 1.4 January 2009 Pre - Construction Notification (PCN) Form A. Applicant Information 1. Processing 1 a. Type(s) of approval sought from the Corps: ❑Q Section 404 Permit ❑ Section 10 Permit 1 b. Specify Nationwide Permit (NWP) number: 14 or General Permit (GP) number: 1c. Has the NWP or GP number been verified by the Corps? ❑x Yes E] No 1d. Type(s) of approval sought from the DWQ (check all that apply): x 401 Water Quality Certification — Regular ❑ Non -404 Jurisdictional General Permit ❑ ❑ 401 Water Quality Certification — Express ❑ Riparian Buffer Authorization 1e. Is this notification solely for the record because written approval is not required? For the record only for DWQ 401 Certification: ❑ Yes ❑x No For the record only for Corps Permit: ❑ Yes ❑x No 1f. Is payment into a mitigation bank or in -lieu fee program proposed for mitigation of impacts? If so, attach the acceptance letter from mitigation bank or in -lieu fee program. ❑ Yes Q No 1g. Is the project located in any of NC's twenty coastal counties. If yes, answer 1h below. ❑ Yes E] No 1 h. Is the project located within a NC DCM Area of Environmental Concern (AEC)? ❑ Yes ❑x No 2. Project Information 2a. Name of project: Crossing of UT to Rocky River 2b. County: Cabarrus 2c. Nearest municipality / town: Kannapolis 2d. Subdivision name: Waterford on the Rocky River 2e. NCDOT only, T.I.P. or state project no: n/a _. 3. Owner Information L-L-3' Ll 3a. Name(s) on Recorded Deed: Lennar Carolinas, LLC 3b. Deed Book and Page No. DB10207 PGO142 i 3c. Responsible Party (for LLC if applicable): Thomas Johnson DENR i ER RESOURCES aoi a BUFF 3d. Street address: 11230 Carmel Commons Blvd 3e. City, state, zip: Charlotte, NC 28226 3f. Telephone no.: 704 - 621 -8395 3g. Fax no.: 3h. Email address: thomas.johnson @lennar.com Page 1 of 10 PCN Form - Version 1.4 January 2009 4. Applicant Information (if different from owner,) 4a Applicant is ❑ Agent ❑ Other, specify 4b Name 4c Business name (if applicable) - 4d Street address 4e City, state, zip 0 Telephone no 4g Fax no 4h Email address 5. Agent/Consultant Information (if applicable) 5a Name Tamp Bandy 5b Business name (if applicable) Wetland and Natural Resource Consultants 5c Street address 1646 Machine Shop Road 5d City, state, zip Hickory NC 28602 5e Telephone no 828- 302 -3437 5f Fax no n/a 5g Email address tamp @wetland - consultants com Page 2 of 10 B. Project Information and Prior Project History 1. Property Identification 1a Property identification no (tax PIN or parcel ID) 46727452910000 lb Site coordinates (in decimal degrees) Latitude 35 45133 °N Longitude -8075311 1c Property size —5645 acres 2. Surface Waters 2a Name of nearest body of water to proposed project UT to Rocky River 2b Water Quality Classification of nearest receiving water C 2c Riverbasin Yadkin Pee -Dee 3: Project Description 3a Describe the existing conditions on the site and the general land use in the vicinity of the project at the time of this application Site partially developed for single family residential subdivision 3b List the total estimated acreage of all existing wetlands on the property —1 acre 3c List the total estimated linear feet of all existing streams (intermittent and perennial) on the property —750 ft 3d Explain the purpose of the proposed project Construct access road 3e Describe the overall project in detail, including the type of equipment to be used Construction of access road for subdiivision 4. Jurisdictional Determinations 4a Have jurisdictional wetland orstream determinations by the Corps or State been requested or obtained for thin property / project (including all nor phases) in the past? 0 Yes ❑ No ❑ Unknown Comments expired 4b If the Corps made the jurisdictional determination, what type of=determination was made ❑preliminary ❑x Final 4c If yes, who delineated the jurisdictional areas? Name (if known) Pamela Bowman Agency /Consultant Company WNR Other 4d If yes, list the dates of the Corps jurisdictional determinations or State determinations and attach documentation 2004 S. Project History 5a Have permits or certifications been requested or obtained for this project (including all prior phases) in the past? ® Yes ❑ No ❑ Unknown 5b If yes, explain in detail according to "help file" instructions Prior approvals Action ID 200530119 and DWQ# 06 -0796 Current USACE permit verification SAW - 2014 -00500 (attached) 6. Future Project Plans ,6a Is this a phased project? x❑ Yes ❑ No 6b If yes, explain Project was delayed due to recession Finab road crossing to be constructed upon receipt of DWR 401 WQC Page 3 of 10 PCN Form — Version 14 January 2009 C. Proposed Impacts Inventory 1. Impacts Summary la Which sections were completed below for your project (check all that apply) ❑ Wetlands ® Streams — tributaries ❑ Buffers ❑ Open Waters ❑ Pond Construction 2. Wetland Impacts If there are wetland impacts proposed on the site, then complete this question for each wetland area impacted 2a Wetland impact number Permanent (P) or Temporary T 2b Type of impact 2c Type of wetland 2d Forested 2e Type of jurisdiction Corps (404,10) or DWQ (401, other) 2f Area of impact (acres) W1 Choose one Choose one Yes /No - W2 - Choose one Choose one Yes/No - W3 - Choose one Choose one Yes /No - W4 Choose one Choose one Yes/No - W5 Choose one Choose one Yes /No - W6 - Choose one Choose one Yes /No - 2g Total Wetland Impacts: 2h Comments 3. Stream Impacts If there are perennial or intermittent stream impacts (including temporary impacts) proposed on the site, then complete this question for all stream sites impacted 3a Stream impact number Permanent (P) or Temporary (T) 3b Type of impact 3c Stream name 3d Perennial (PER) or intermittent (INT)? 3e Type of jurisdiction 3f Average stream width (feet) 3g Impact length (linear feet) S1 P Culvert UT to Rocky River PER Corps 12 80 S2 - Choose one - - S3 - Choose one - S4 - Choose one - - S5 - Choose one - - S6 - Choose one - - 3h Total stream and tributary impacts 80 31 Comments Page 4 of 10 PCN Form — Version 1 4 January 2009 4. Open Water Impacts If there are proposed impacts to lakes, ponds, estuaries, tributaries, sounds, the Atlantic Ocean, or any other open water of the U S then indiv ually list all open water impacts below 4a Open water impact number Permanent (P) or Temporary T 4b Name of waterbody (if applicable) 4c Type of impact 4d Waterbody type 4e Area of impact (acres) 01 - Choose one Choose 02 - Choose one Choose 03 - Choose one Choose 04 - Choose one Choose 4f Total open water impacts 4g Comments S. Pond or Lake Construction If pond or lake construction proposed, the complete the chart below 5a Pond ID number 5b Proposed use or purpose of pond 5c Wetland Impacts (acres) 5d Stream Impacts (feet) 5e Upland (acres) Flooded Filled Excavated Flooded Filled Excavated P1 Choose one P2 Choose one 5f Total: 5g Comments 5h Is a dam high hazard permit required ❑ Yes ❑ No If yes, permit ID no 51 Expected pond surface area (acres) 51 Size of pond watershed (acres) 5k Method of construction 6. Buffer Impacts (for DWQ) If project will impact a protected riparian buffer, then complete the chart below If yes, then individually list all buffer impacts below If any impacts require mitigation, then you MUST fill out Section D of this form 6a. Project is in which protected basin? ❑ Neuse ❑ Tar - Pamlico ❑ Catawba ❑ Randleman ❑ Other 6b Buffer Impact number — Permanent (P) or Temporary T 6c Reason for impact 6d Stream name 6e Buffer mitigation required? 6f Zone 1 impact (square feet ) 6g Zone 2 impact (square feet B1 Yes /No B2 Yes/No B3 - Yes /No B4 - Yes /No B5 - Yes /No B6 Yes /No 6h Total Buffer Impacts: 61 Comments Page 5 of 10 D. Impact Justification and Mitigation 1. Avoidance and Minimization la Specifically describe measures taken to avoid or minimize the proposed impacts in designing project Access road location and site plan designed to avoid stream and wetland impacts 1 b Specifically describe measures taken to avoid or minimize the proposed impacts through construction techniques preferred site plan would impact hundreds of additional feet of stream channel and wetlands construction will avoid wetland and stream impacts 2. Compensatory Mitigation for Impacts to Waters of the U.S. or Waters of the State 2a Does the project require Compensatory Mitigation for impacts to Waters of the U S or Waters of the State? ❑ Yes ❑x No Compensatory mitigation not required in previous authorization 2b If yes, mitigation is required by (check all that apply) ❑ DWQ ❑ Corps 2c If yes, which mitigation option will be used for this project? ❑ Mitigation bank El Payment to in -lieu fee program ❑ Permittee Responsible Mitigation 3. Complete if Using a Mitigation Bank 3a Name of Mitigation Bank 3b Credits Purchased (attach receipt and letter) Type Choose one Type Choose one Type Choose one Quantity Quantity Quantity 3c Comments 4. Complete if Making a Payment to In -lieu Fee Program 4a Approval letter from in -lieu fee program is attached ❑ Yes 0 Stream mitigation requested linear feet 4c If using,stream mitigation, stream temperature- Choose one 4d Buffer mitigation requested (DWQ only) square feet 4e Riparian wetland mitigation requested acres 4f Non - ripanan wetland mitigation requested acres 4g Coastal (tidal) wetland mitigation requested acres 4h Comments 5. Complete if Using a Permittee Responsible Mitigation Plan 5a If using a permittee responsible mitigation plan, provide a description of the proposed mitigation plan Page 6 of 10 PCN Form — Version 1 4 January 2009 6. Buffer Mitigation (State Regulated Riparian Buffer Rules) — required by DWQ 6a Will the project result in an impact within a protected riparian buffer that requires buffer mitigation? x El Yes No 6b If yes, then.identify the square feet of impact to each zone of the riparian buffer that requires mitigation Calculate the amount of mitigation required Zone 66 Reason for impact 6d Total impact (square feet) Multiplier 6e Required mitigation (square feet) Zone 1 3 (2 for Catawba) Zone 2 1 5 6f Total buffer mitigation required: 6g If buffer,mitigation is required, discuss what type of mitigation is proposed (e g , payment to private mitigation bank, permittee responsible riparian buffer restoration, payment into an approved in -lieu fee fund) 6h Comments Page 7 of 10 E. Stormwater Management and Diffuse Flow Plan (required by DWQ) 1. Diffuse Flow Plan la Does the project include or is it adjacent to protected riparian buffers identified ❑ Yes ❑X No within one of the NC Riparian Buffer Protection Rules? lb If yes, then is a diffuse flow plan included? If no, explain why Stormwater from road storm system to be collected and discharged to bmp's and released at ❑ Yes ❑ No non - erosive amounts through existing Cabarrus County RSOD buffers 2. Stormwater Management Plan 2a What is the overall percent imperviousness of this project? less than 24% 2b Does this project require a Stormwater Management Plan? ❑ Yes ❑ No 2c If this project DOES NOT require a Stormwater Management Plan, explain why Stormwater to be collected and released into floodplam through dry detention ponds and engineered outlet structures outside of regulated stream limits, prior plans proposed discharges directly to streams 2d If this project DOES require a Stormwater Management Plan, then provide a brief, narrative description of the plan 2e Who will be responsible for the review of the Stormwater Management Plan? Kannapolis / Concord 3. Certified Local Government Stormwater Review 3a In which local government's jurisdiction is this project? Kannapolis / Concord ❑ Phase II ❑NSW 3b Which of the following locally - implemented stormwater management programs USMP apply (check all that apply) ❑ Water Supply Watershed ❑ Other 3c Has the approved Stormwater Management Plan with proof of approval been ❑Yes ❑ No attached? 4. DWQ Stormwater Program Review ❑ Coastal counties ❑ HQW 4a Which of the following state - implemented stormwater management programs apply ❑�ORW (check all that apply) ❑ Session Law 2006 -246 ❑ Other 4b Has the approved Stormwater Management Plan with proof of approval been ❑ Yes ❑ No attached? 5. IDWQ 401 Unit Stormwater Review 5a Does the Stormwater Management Plan meet the appropriate requirements? ❑ Yes ❑ No 5b Have all of the 401 Unit submittal requirements been met? ❑ Yes ❑ No Page 8 of 10 PCN Form — Version 1 4 January 2009 F. Supplementary Information 1. Environmental Documentation (DWQ Requirement) la Does the project involve an expenditure of public (federal /state /local) funds or the ❑ Yes Q No use of public (federal /state) land? lb If you answered "yes" to the above, does the project require preparation of an environmental,document pursuant to the requirements of the National or State El Yes ❑ No (North Carolina) Environmental Policy Act (NEPA/SEPA)? 1 c If you answered "yes" to the above, has the document review been finalized by the State Clearing House? (If so, attach a copy of the NEPA or SEPA final approval ❑ Yes ❑ No letter) Comments 2. Violations (DWQ Requirement) 2a Is,the site in violation of DWQ Wetland Rules (15A NCAC 2H 0500), Isolated Wetland Rules (15A NCAC 2H 1300), DWQ Surface Water or Wetland Standards, ❑ Yes No or Riparian Buffer Rules (15A NCAC 2B 0200)? 2b IsAhis an after - the -fact permit application? ❑Yes ❑ No 2c If you answered "yes" to one or both of the above questions, provide an explanation of the violation(s) 3. Cumulative Impacts (DWQ Requirement) 3a Will this protect (based on past and reasonably anticipated future impacts) result in ❑Yes ❑x No additional development, which could impact nearby downstream water quality 3b If you answered "yes" to the above, submit a qualitative or quantitative cumulative impact analysis in accordance with the most recent DWQ policy If you answered "no," provide a short narrative description 4. Sewage Disposal (DWQ Requirement) 4a Clearly detail the ultimate treatment methods and disposition (non - discharge or discharge) of wastewater generated from the proposed project, or available capacity of the subject facility tie to existing ss utility line Page 9 of 10 PCN Form — Version 1 4 January 2009 5. Endangered Species and Designated Critical Habitat (Corps Requirement) 5a Will this project occur in or near an area with federally protected species or ❑ Yes ❑Q No habitat? 5b Have you checked with the USFWS concerning Endangered Species Act ❑ Yes ® No impacts? 5c If yes, indicate the USFWS Field Office you have contacted - 5d What data sources did you use to determine whether your site would impact Endangered Species or Designated Critical Habitat? No impacts identified in previous authorization 6. Essential Fish Habitat (Corps Requirement) 6a Will this project occur in or near an area designated as essential fish habitat? ❑ Yes Q No 6b, What data sources did you use to determine whether your site would impact Essential Fish Habitat? No, impacts, identified in previous authorization 7. Historic or Prehistoric Cultural Resources (Corps Requirement) 7a Will this project occur in or near an area that the state, federal, or tribal governments have designated as having historic or cultural preservation ❑ Yes ❑x No status (e g , National Historic Trust designation or properties significant in North Carolina history and archaeology)? 7b What data sources did you use to determine whether your site would impact historic or archeological resources? No impacts identified in previous authorization 8. Flood Zone Designation (Corps Requirement) 8a Will this project occur in a FEMA - designated 100 -year floodplain? —T-21 Yes ❑ No 8b. If yes, explain how project meets FEMA requirements designed, fto meet requirements (see attached engineering study) 8c What source(s) did you use to make the floodplam determination? project, engineers �E~►.ftJ11�c_ L1i2�t.3��Asi l,�.JC� —T–M 1W� �uili�l S l t�l S 0. ,� / �i v - ry 2Il l r Appli aht/Agent's Signature Applicant /Agent's Printed Name Date (Agent's signature is valid only ifan authorization letter from the,a p licant is provided Page 10 of 10 Preliminary Culvert Data — 01/13/2014 Waterford on the Rocky River Phase 2B Summary Information for the Proposed Culvert on Travertine Trail at Sta 19 +10 The information below is based on 09/15/2013 preliminary plan and profile sheet for Topaz Plaza 13 +20 to 18 +03.33 as designed by Northeast Engineering The information is also based on the March 2, 2009 Flood Insurance Study for the City of Kannapohs, terrain data from the NC Flood Plain Mapping Program, and survey data from NorStar Land Surveying, Inc. Based on conversations with Wes Webb, New River Engineering, PLLC (NRE) delineated and created a hydrologic model of the un -named tributary from the confluence of the Rocky River to the headwaters The proposed culvert is located approximately 1,450 feet upstream of the confluence with the river The watershed of the un -named tributary is approximately 582 acres or 0.9 square miles The resulting discharge at the proposed culvert location is 674 78 cfs for the 100 -year 24 -hour event A HEC -RAS hydraulic model was created by combining the 20 foot terrain grade information from the NC Floodmapping Program with the survey data points. A TIN was created using the survey data near the location and the terrain grid outside the area of the proposed culverts. HEC- GeoRAS was then used to create a hydraulic model. The initial plan and profile had selected 90 inch RCPs for the crossing The pipes were sized up one size to 96'inch RCPs to carry the flow Based on additional conversations with the design team, one of the 96 inch RCPs was dropped 1 foot to accommodate ecological passage as required by the 401/404 permit The road elevation data in the hydraulic model is based on the profile drawing from NE Engineering The HEC -RAS Sta 762.5 matches the profile station of 19 +10. Resulting Culvert Parameters: Length: 80 feet Size: Two 96 inch RCP Culvert 1 will be located at the existing NEE Sta 19 +14 S (center of the pipe) Invert in: 629 2 Invert out: 628 2 Culvert 2 will be located at the existing NEE Sta 19 +05 5 (center of the pipe) Invert in: 628.2 Invert out. 627 5 (Buried one foot) Anticipating Concrete headwalls with the bell end of the culvert upstream With this configuration, there is 0 73' increase in the 100 -year floodplain elevation which zeros out 35 feet upstream of the face of th&culvert /headwall The prey— culvert flood elevation dust above the culvert is 636 51 and the post - culvert flood elevation'is 637 24 This data is being submitted to the design team as preliminary. Please contact Robert Billings, PE at 704- 249 -5538 or at billings @newrivereng com if we need to make changes. Add I Copy J Debt.... I Ghent lD SolrtimCrrleria Highest U.S.EG Rename... JJ Shape r, ar Spsn F Diameter F Chart p: 11 - Concrete Pipe Culvert Scab p: 11 -Square edge entrance with headwall Distance to Upstrm XS: �F3_5 — Upstream Invert Eby. 629.2 Culvert Larglh ISO Downstream Invert Eby. 628.5 Entrance Loss Coelf: �0.2 L_4 It identical barrels: 1�- Exit Loss Coeff: I' — Manniig's n for Top: 0.013 �? Upstream Downstream Manning's n For Bottorrc 0.013 1 758. 773.25 �— 2 Depth to use Bolton n: ry 3 DepthBbdu>d F— 4 0 r Help Select cuived to edit ---- - - - - -- Cuhved Data Editor Add I Copy I Delete ... Culvert ID SoltionCfihm Hi¢radU.S.EG Rename Shape: P _ Sp., F_ Diameter. to Chart #: 1 - Concrete Pipe Culvert J Scale W. 1 - Square edge entrance with headwall Distance to UpstrmXS: r35 Upstream Invat Ebv: JUG.2 Culvert Length �— Downstream Invert Eby. 627.5 Entrance Loss Coeff: 0.0.2 —_W tf iden cal barrels : �1 Exit Loss CoefE I 1 Manrregs n for Top: D013 I3 Upstream Dowrat;; Manrw4s n for Bottom: 0.035 1 767. 782.25 Depth to use Bottom n y 1 2 � — 3 Depth Blocked f 4 DK Cancel Hdp Select alvert to a& F• 'Ar cpb -, F.I: 'vie: s'r -.n f__'I:a_- I�euesrr I- - -- wa— .a.n------ - - - - - -- J YO ` ZSO£ l /I? Hd - 213AIN AHDf �R} Yl III w 0 w N w s ���: z ME - \ — I / cc — \ \� — d ilI � NW\\ o /* %%j "e ��' It N s IL a w U z O U Ir O U) I� Z w I ❑ iU Z a �u €° Of Q z U K J oxz L L CJ O W2Q =aiU �0< Zzz O Q J N❑ LL O 1.L Ir W Q P,1 Y� e�' ?e v IS REs $Q o � r _t2oz a 0 o 0 a pp— ■—■ 09 0 RZ g� o o It ���: z ME - \ — I / cc — \ \� — d ilI � NW\\ o /* %%j "e ��' It N s IL a w U z O U Ir O U) I� Z w I ❑ iU Z a �u €° Of Q z U K J oxz L L CJ O W2Q =aiU �0< Zzz O Q J N❑ LL O 1.L Ir W Q P,1 Y� e�' ?e v IS REs $Q o � r _t2oz . c , U.S. ARMY CORPS OF ENGINEERS WILMINGTON DISTRICT Action ID SAW -2014 -00500 County Cabarrus' USGS Quad- NC- Cornelius Original # 2005-30119 corrected'to,2004- 300119 GENERAL PERMIT (REGIONAL AND NATIONWIDE) VERi'FiCATION PTgperty,Owner / Authorized Agent. Thomas Johnson Lennar Carolinas, LLC Address: l 230'Carmel Commons'Blvd Charlotte, North, Carolina 28226 Telephone No Size,and location of property (water body, road, name /number, town; _,etc.) The project is located at 2695 .Tim JohnsodRd.. Concord, NC 28027 Coordinates: 35.45133, - 80.7531'1 Descnption�ofprojects area and,activity: This permit authorizes eii material associated with therinstallaiion of 80 Linear feet.of,&& Applicable Law ® Section 404 (Clean Water Act, 33 USC 1344) ❑ 'Section 10 (Rivers and Harbors Act, 33 USC-403) Authorization Regional General'Permit Number Nationwide Pernut Number 14 Additional Remarks and/or Special Permit Conditions *Culverts greater than 48 inches in diameter -will be buried at least one,foot -below the_bed of the stream. Culverts 48 inches or less shall be buried at an appropriate depth t6'mainta_in aquatic passage as defined in Final Regional Condition 3.6 attached to,this NWP. Youriwork i"s authorized by the above referenced permit provided it is accomplished in strict accordance with the attached conditions and-your plans- submitted, on, February 26, 2014. Any violation of the-aftached,conditions or deviati on.from your submitted plans may subject the permittee to a stop work order, a restoration order and/or apprgonate:legal action This verification will remain valid until the expiration date identified below unless,tbe nationwide authonzduon is modified, suspended or revoked If, ,prior to the expiration ,date identified below, the nationwide permit autfiorization'fs��reissued and/or-modified, this verification will remain valid until the expiration date identified belijw, provided it complies with all requirements of the modified nationwide permit lf'the nationwide permit authorization expires or is suspended, revoked, or is'modified; such that theRactivity, would, no longer comply with the'terms,and conditions of the nationwide permit, activities which have comimenced•(i e , are -under constructibn) or are undef- contract to commence'in reliance upon themationwide permit, will remam'authonzed provided the activity is completed within twelve months of the date of the nationwide permit's expiration, modification or revocation, unless discretibnary authority has been exercised on a case -by -case basis to modify, suspend or revoke the authorization Activities subject to Section 404 (as mdicated above) may also require an individual Section 401 Water Quality Certification. You should contact the NC Division of Water Quality (telephone,(919) 807 -6300) to determine Section 401 requirements You may also visit their website at: hqp / /portal ncdenr org/web/wa /swp /ws /webscapc For activities occurring within -the twenty coastal counties sublectto regulation under the Coastal Area Management Act (CAMA), prior to begiiintrig work you must contact the N' C .Division of Coastal Management This Department of the Army verification' does no_ t- relieve the permittee of the responsibility to obtain any other required Federal, State or local approvals /permits If there are any questions regarding this verification, any of the conditions of theTermit, of the Corps of Engineers regulatory program, please contact William Elliott at 828 - 271 -7980 ogpwy� by _ EL'LIOTT WILLI ;,�;WWAAUN4ptT018 Date April 10,2014 AM Corps Regulatory Official _William Elliott T"& .1048694604 _ "in— iuuewn.wvi .„.„«, T pYe2pt�D1M 0!16.]8 01'OV Expiration Date of Verification- March 18, 2017 The Wilmington District is committed to providing'the highest level of support to'the public To help us ensure we cont ue,,to do so, please complete the Customer, Satisfaction Survey located at- our,website at http //tSer2 nwp'usace army mil /survey html to,complete the,survey online