Loading...
HomeMy WebLinkAboutNC0086924_Renewal (Application)_20220908 ,4 ROY COOPER Governor ELIZABETH S.BISER Gsq QUA?,V,S0- Secretary RICHARD E.ROGERS,JR. NORTH CAROLINA Director Environmental Quality September 08, 2022 Tyrell County Attn: David L. Clegg, Town Manager PO Box 449 Columbia, NC 27925-0449 Subject: Permit Renewal Application No. NC0086924 Reverse Osmosis WTP Tyrrell County Dear Applicant: The Water Quality Permitting Section acknowledges the September 8, 2022, receipt of your permit renewal application and supporting documentation. Your application will be assigned to a permit writer within the Section's NPDES WW permitting branch. Per G.S. 150B-3 your current permit does not expire until permit decision on the application is made. Continuation of the current permit is contingent on timely and sufficient application for renewal of the current permit. The permit writer will contact you if additional information is required to complete your permit renewal. Please respond in a timely manner to requests for additional information necessary to allow a complete review of the application and renewal of the permit. Information regarding the status of your renewal application can be found online using the Department of Environmental Quality's Environmental Application Tracker at: https://deq.nc.gov/permits-regulations/permit-guidance/environmental-application-tracker If you have any additional questions about the permit, please contact the primary reviewer of the application using the links available within the Application Tracker. Sincerely, Wren T edford Administrative Assistant Water Quality Permitting Section ec: WQPS Laserfiche File w/application North Carolina Department of Environmental Quality Division of Water Resources Washington Regional Office 1943 Washington Square Mall Washington.North Carolina 27889 Q 252.946.6481 I � Tyrrell County Board of Commissioners Post Office Box 449 Columbia, North Carolina 27925 Telephone (252) 796-1371 Nathan T. Everett, Chairman David L. Clegg, County Manager and Attorney Nina B. Griswell,Vice Chairman Penny Rhodes Owens, Clerk to the Board 4.1 Jordan R. Davis Dorothy Spencer Robert Thompson September 6, 2022 RECEIVED SEP 0 8 2022 Division of Water Resources NCDEQIDWRINPDES Water Quality Permitting Section NPDES 1617 Mail Service Center Raleigl.. NC 2 7699-1 6 1 7 RE: Tyrrell County NPDES renewal permit application for NC0086924 Dear All: Please find the original and two copies of the above referenced renewal permit application. Thank ,ou for your attention to this matter. Sincerely, David L. Clegg EPA Identification Number NPDES Permit Number Facility Name Form Approved 03/05/19 NC0086924 Tyrrell County RO WTP Bull's Bay OMB No.2040-0004 Form U.S. Environmental Protection Agency 2A "EPA Application for NPDES Permit to Discharge Wastewater NPDES NEW AND EXISTING PUBLICLY OWNED TREATMENT WORKS SECTION 1. BASIC APPLICATION INFORMATION FOR ALL APPLICANTS(40 CFR 122.21(j)(1)and(9)) 1.1 Facility name Tyrrell County RO WTP-Bull's Bay Mailing address(street or P.O. box) PO Box 449 City or town State ZIP code 0 Columbia NC 27925-0449 Contact name(first and last) Title Phone number Email address David L.CleggCountyManager g (252)796-1371 dclegg@tyrrellcounty.net Location address(street, route number,or other specific identifier) ❑ Same as mailing address .75 3868 Albemarle Church Road w City or town State ZIP code Columbia NC 27925 1.2 Is this application for a facility that has yet to commence discharge? ❑ Yes 4 See instructions on data submission ❑ No requirements for new dischargers. 1.3 Is applicant different from entity listed under Item 1.1 above? ❑ Yes ✓❑ No 4 SKIP to Item 1.4. Applicant name Applicant address(street or P.O. box) 0 ca Eo City or town State ZIP code CO Contact name(first and last) Title Phone number Email address 0 n. 1.4 Is the applicant the facility's owner,operator, or both?(Check only one response.) ❑ Owner ❑ Operator ❑✓ Both 1.5 To which entity should the NPDES permitting authority send correspondence?(Check only one response.) El Facility ❑ Applicant ❑ Facility and applicant (they are one and the same) 1.6 Indicate below any existing environmental permits. (Check all that apply and print or type the corresponding permit number for each.) Existing Environmental Permits a ✓❑ NPDES(discharges to surface ❑ RCRA(hazardous waste) ❑ UIC(underground injection R water) control) E NC0086924 o ❑ PSD(air emissions) ❑ Nonattainment program(CM) ❑ NESHAPs(CM) rn ❑ Ocean dumping(MPRSA) ❑ Dredge or fill(CWA Section El Other(specify) 404) EPA Form 3510-2A(Revised 3-19) Page 1 EPA Identification Number NPDES Permit Number Facility Name Form Approved 03/05/19 NC0086924 Tyrrell County RO WTP Bull's Bay OMB No.2040-0004 1.7 Provide the collection system information requested below for the treatment works. Municipality Population Collection System Type Ownership Status Served Served (indicate percentage) 100 %separate sanitary sewer 0 Own 0 Maintain Tyrrell County 2430 %combined storm and sanitary sewer 0 Own 0 Maintain rn 0 Unknown ❑ Own 0 Maintain o %separate sanitary sewer ❑ Own 0 Maintain .c. %combined storm and sanitary sewer ❑ Own 0 Maintain cu Q 0 Unknown 0 Own 0 Maintain a %separate sanitary sewer 0 Own 0 Maintain %combined storm and sanitary sewer 0 Own 0 Maintain E 0 Unknown 0 Own 0 Maintain r %separate sanitary sewer 0 Own 0 Maintain cn %combined storm and sanitary sewer 0 Own 0 Maintain o 0 Unknown 0 Own 0 Maintain Total °' Population 2430 o o Served Separate Sanitary Sewer System Combined Storm and Sanitary Sewer Total percentage of each type of sewer line(in miles) na % 1.8 Is the treatment works located in Indian Country? c 0 ❑ Yes ✓❑ No U = 1.9 Does the facility discharge to a receiving water that flows through Indian Country? a ❑ Yes ❑✓ No 1.10 Provide design and actual flow rates in the designated spaces. Design Flow Rate 0.064 mgd �, Annual Average Flow Rates(Actual) Two Years Ago Last Year This Year c `° 9 0.074 m_ d c o 0.070 mgd 0.087 mgd LL Maximum Daily Flow Rates(Actual) o Two Years Ago Last Year This Year 0.183 mgd 0.8 mgd 0.208 mgd ti 1.11 Provide the total number of effluent discharge points to waters of the United States by type. oTotal Number of Effluent Discharge Points by Type 0- 0-0- Constructed fl)o,F Combined Sewer Treated Effluent Untreated Effluent Overflows Bypasses Emergency -0 Overflows U . N 0 1 EPA Form 3510-2A(Revised 3-19) Page 2 EPA Identification Number NPDES Permit Number Facility Name Form Approved 03/05/19 NC0086924 Tyrrell County RO WTP Bull's Bay OMB No.2040-0004 Outfalls Other Than to Waters of the United States 1.12 Does the POTW discharge wastewater to basins,ponds,or other surface impoundments that do not have outlets for discharge to waters of the United States? ❑ Yes ❑✓ No SKIP to Item 1.14. 1.13 Provide the location of each surface impoundment and associated discharge information in the table below. Surface Impoundment Location and Discharge Data Average Daily Volume Continuous or Intermittent Location Discharged to Surface Impoundment (check one) ❑ Continuous gpd ❑ Intermittent ❑ Continuous gpd ❑ Intermittent ❑ Continuous gpd ❑ Intermittent 2 1.14 Is wastewater applied to land? ❑ Yes ❑� No 4 SKIP to Item 1.16. o 1.15 Provide the land application site and discharge data requested below. H Land Application Site and Discharge Data 6 Continuous or Location Size Average Daily Volume Intermittent 12) Applied (check one) 0 Continuous N acres gpd 0 Intermittent 0 Continuous Zr) acres gpd 0 Intermittent acresgpd ❑ Continuous 0 Intermittent U) 1.16 Is effluent transported to another facility for treatment prior to discharge? o ❑ Yes ❑ No 3 SKIP to Item 1.21. 1.17 Describe the means by which the effluent is transported(e.g., tank truck, pipe). 1.18 Is the effluent transported by a party other than the applicant? ❑ Yes ❑ No -) SKIP to Item 1.20. 1.19 Provide information on the transporter below. Transporter Data Entity name Mailing address(street or P.O.box) City or town State ZIP code Contact name(first and last) Title Phone number Email address EPA Form 3510-2A(Revised 3-19) Page 3 EPA Identification Number NPDES Permit Number Facility Name Form Approved 03/05/19 NC0086924 Tyrrell County RO WTP Bull's Bay OMB No.2040-0004 1.20 In the table below, indicate the name, address,contact information, NPDES number, and average daily flow rate of the receiving facility. Receiving Facility Data Facility name Mailing address(street or P.O. box) City or town State ZIP code 0 U co Contact name(first and last) Title 0 115 Phone number Email address cNPDES number of receiving facility(if any) 0 None Average daily flow rate mgd 0 1.21 Is the wastewater disposed of in a manner other than those already mentioned in Items 1.14 through 1.21 that do not have outlets to waters of the United States(e.g., underground percolation,underground injection)? ❑ Yes ❑✓ No - SKIP to Item 1.23. 0 1.22 Provide information in the table below on these other disposal methods. Information on Other Disposal Methods r Disposal Annual Average Location of Size of Continuous or Intermittent -0 Method Daily Discharge Description Disposal Site Disposal Site Volume (check one) 0 Continuous acres gpd ❑ Intermittent acres gpd 0 Continuous 0 Intermittent acresgpd ❑ Continuous ❑ Intermittent 1.23 Do you intend to request or renew one or more of the variances authorized at 40 CFR 122.21(n)?(Check all that apply. a) N Consult with your NPDES permitting authority to determine what information needs to be submitted and when.) o co ❑ Discharges into marine waters(CWA ❑ Water quality related effluent limitation(CWA Section cr Section 301(h)) 302(b)(2)) ✓❑ Not applicable 1.24 Are any operational or maintenance aspects(related to wastewater treatment and effluent quality)of the treatment works the responsibility of a contractor? ❑ Yes ❑✓ No +SKIP to Section 2. 1.25 Provide location and contact information for each contractor in addition to a description of the contractor's operational and maintenance responsibilities. Contractor Information Contractor 1 Contractor 2 Contractor 3 o Contractor name (company name) Mailing address (street or P.O. box) City, state,and ZIP code Contact name(first and c°� last) Phone number Email address Operational and maintenance responsibilities of contractor EPA Form 3510-2A(Revised 3-19) Page 4 EPA Identification Number NPDES Permit Number Facility Name Form Approved 03/05/19 NC0086924 Tyrrell County RO WTP Bull's Bay OMB No.2040-0004 SECTION 2.ADDITIONAL INFORMATION(40 CFR 122.21(j)(1)and(2)) o Outfalls to Waters of the United States 2.1 Does the treatment works have a design flow greater than or equal to 0.1 mgd? rn o ❑✓ Yes ❑ No 4 SKIP to Section 3. 0 2.2 Provide the treatment works'current average daily volume of inflow Average Daily Volume of Inflow and Infiltration '75 and infiltration. o gpd Indicate the steps the facility is taking to minimize inflow and infiltration. -0 R no collection system 0 0 w 2.3 Have you attached a topographic map to this application that contains all the required information?(See instructions for Q. • a specific requirements.) o E ❑✓ Yes ❑ No E 2.4 Have you attached a process flow diagram or schematic to this application that contains all the required information? oT. (See instructions for specific requirements.) rn LT as ❑✓ Yes ❑ No 2.5 Are improvements to the facility scheduled? ❑ Yes ❑✓ No 4 SKIP to Section 3. Briefly list and describe the scheduled improvements. 0 1. a, d E m a 2. E 0 3. co 4. R 2.6 Provide scheduled or actual dates of completion for improvements. Scheduled or Actual Dates of Completion for Improvements • Affected Attainment of a) Scheduled Begin End Begin Outfalls Operational 2 Improvement Construction Construction Discharge p from above) (list outfall Level ( number) (MM/DD/YYYY) (MM/DD/YYYY) (MM/DD/YYYY) (MM/DD/YYYY) 1. 2 co 3. 4. 2.7 Have appropriate permits/clearances concerning other federal/state requirements been obtained?Briefly explain your response. ❑ Yes ❑ No ❑ None required or applicable Explanation: EPA Form 3510-2A(Revised 3.19) Page 5 EPA Identification Number NPDES Permit Number Facility Name Form Approved 03/05/19 NC0086924 Tyrrell County RO WTP Bull's Bay OMB No.2040-0004 SECTION 3.INFORMATION ON EFFLUENT DISCHARGES(40 CFR 122.21(j)(3)to(5)) 3.1 Provide the following information for each outfall. (Attach additional sheets if you have more than three outfalls.) Outfall Number 001 Outfall Number Outfall Number State North Carolina County Tyrrell 0 City or town Columbia Distance from shore 80 ft. ft. ft. Depth below surface 2 ft, ft. ft. Average daily flow rate 0.087 mgd mgd mgd Latitude 35° 56' 16" N Longitude 76° 21' 18" W 3.2 Do any of the outfalls described under Item 3.1 have seasonal or periodic discharges? o ❑ Yes ✓❑ No 4 SKIP to Item 3.4. R 3.3 If so,provide the following information for each applicable outfall. s Outfall Number Outfall Number Outfall Number :o Number of times per year • 0 discharge occurs a Average duration of each `o discharge(specify units) o Average flow of each an mgd mgd d discharge g g g u Months in which discharge occurs 3.4 Are any of the outfalls listed under Item 3.1 equipped with a diffuser? ❑✓ Yes ❑ No 4 SKIP to Item 3.6. 3.5 Briefly describe the diffuser type at each applicable outfall. a Outfall Number o01 Outfall Number Outfall Number aw Outfall Diffuser comprised of 4 o duck-bill rubber diffusers angled up at 45 degrees from horizontal spaced approximately 4 feet apart 15 vi 3.6 Does the treatment works discharge or plan to discharge wastewater to waters of the United States from one or more d discharge points? ❑✓ Yes ❑ No 4SKIP to Section 6. EPA Form 3510-2A(Revised 3-19) Page 6 EPA Identification Number NPDES Permit Number Facility Name Form Approved 03/05/19 NC0086924 Tyrrell County RO WTP Bulls Bay OMB No.2040-0004 3.7 Provide the receiving water and related information(if known)for each outfall. Outfall Number 001 Outfall Number Outfall Number Receiving water name Albemarle Sound Name of watershed, river, Albemarle Sound 0 or stream system -Q U.S. Soil Conservation d Service 14-digit watershed 03010205240040 o code Name of state management/river basin Pasquotank River Basin rn -- U.S. Geological Survey a) 8-digit hydrologic 03010205 ce cataloging unit code Critical low flow(acute) o cfs cfs cfs Critical low flow(chronic) 0 cfs cfs cfs Total hardness at critical mg/L of mg/L of mg/L of low flow 92 CaCO3 CaCO3 CaCO3 3.8 Provide the following information describing the treatment provided for discharges from each outfall. Outfall Number 001 Outfall Number Outfall Number Highest Level of 0 Primary 0 Primary 0 Primary Treatment(check all that 0 Equivalent to 0 Equivalent to 0 Equivalent to apply per outfall) secondary secondary secondary ❑ Secondary 0 Secondary 0 Secondary ❑ Advanced 0 Advanced 0 Advanced ❑ Other(specify) 0 Other(specify) 0 Other(specify) c aDesign Removal Rates by No removal efforts, -U Outfall this is a RO reject flow w o BODs or CBODs na % /o °/o c m E d TSS na I- 1 Not applicable 0 Not applicable 0 Not applicable Phosphorus Pi Not applicable 0 Not applicable 0 Not applicable Nitrogen % % 0/0 Other(specify) m Not applicable 0 Not applicable 0 Not applicable EPA Form 3510-2A(Revised 3-19) Page 7 EPA Identification Number NPDES Permit Number Facility Name Form Approved 03/05/19 NC0086924 Tyrrell County RO WTP Bull's Bay OMB No.2040-0004 3.9 Describe the type of disinfection used for the effluent from each outfall in the table below. If disinfection varies by season,describe below. -0 No disinfection of RO reject flow a) .� 0 0 0 Outfall Number 001 Outfall Number Outfall Number Disinfection type none H Seasons used Dechlorination used? ❑✓ Not applicable ❑ Not applicable pp ❑ Not applicable ❑ Yes ❑ Yes ❑ Yes ❑ No ❑ No El No 3.10 Have you completed monitoring for all Table A parameters and attached the results to the application package? ✓❑ Yes ❑ No 3.11 Have you conducted any WET tests during the 4.5 years prior to the date of the application on any of the facility's discharges or on any receiving water near the discharge points? ❑✓ Yes ❑ No 4 SKIP to Item 3.13. 3.12 Indicate the number of acute and chronic WET tests conducted since the last permit reissuance of the facility's discharges by outfall number or of the receiving water near the discharge points. Outfall Number 001 Outfall Number Outfall Number Acute Chronic Acute Chronic Acute Chronic Number of tests of discharge 19 water Number of tests of receiving water 3.13 Does the treatment works have a design flow greater than or equal to 0.1 mgd? ,� ❑✓ Yes ❑ No 4 SKIP to Item 3.16. 3.14 Does the POTW use chlorine for disinfection, use chlorine elsewhere in the treatment process, or otherwise have reasonable potential to discharge chlorine in its effluent? ❑ Yes 4 Complete Table B, including chlorine. ✓❑ No 4 Complete Table B,omitting chlorine. 3.15 Have you completed monitoring for all applicable Table B pollutants and attached the results to this application package? ❑Q Yes ❑ No 3.16 Does one or more of the following conditions apply? • The facility has a design flow greater than or equal to 1 mgd. • The POTW has an approved pretreatment program or is required to develop such a program. • The NPDES permitting authority has informed the POTW that it must sample for the parameters in Table C,must sample other additional parameters(Table D),or submit the results of WET tests for acute or chronic toxicity for each of its discharge outfalls(Table E). ❑ Yes 4 Complete Tables C, D, and E as applicable. ElNo -) SKIP to Section 4. 3.17 Have you completed monitoring for all applicable Table C pollutants and attached the results to this application package? ❑ Yes ✓❑ No 3.18 Have you completed monitoring for all applicable Table D pollutants required by your NPDES permitting authority and attached the results to this application package? El Yes ❑ No additional sampling required by NPDES permitting authority. EPA Form 3510-2A(Revised 3-19) Page 8 EPA Identification Number NPDES Permit Number Facility Name Form Approved 03/05/19 NC0086924 Tyrrell County RO WTP Bull's Bay OMB No.2040-0004 3.19 Has the POTW conducted either(1)minimum of four quarterly WET tests for one year preceding this permit application or(2)at least four annual WET tests in the past 4.5 years? ✓❑ Yes ❑ No 4 Complete tests and Table E and SKIP to Item 3.26. 3.20 Have you previously submitted the results of the above tests to your NPDES permitting authority? ❑ No 4 Provide results in Table E and SKIP to El Yes Item 3.26. 3.21 Indicate the dates the data were submitted to your NPDES permitting authority and provide a summary of the results. Date(s)Submitted Summary of Results (MM/DD/YYYY) 01/12/2018,04/13/2018,07/12/2018, 10/04/2018,01/23/2019, 01/12/2018 04/05/2019,07/11/2019, 10/22/2019,01/10/2020,04/09/2020, = 07/09/2020, 10/08/2020,01/07/2021,04/16/2021,07/15/2021, This drop down does not work,had to put 10/07/2021,01/21/2022,04/07/2022,07/17/2022 All tests Passed o dates in summary field except 1 on 01/12/2018 as 3.22 Regardless of how you provided your WET testing data to the NPDES permitting authority, did any of the tests result in o toxicity? ✓❑ Yes ❑ No 4 SKIP to Item 3.26. F3.23 Describe the cause(s)of the toxicity: 1 test failed,01/12/2018,cause unknown w 3.24 Has the treatment works conducted a toxicity reduction evaluation? El Yes ❑✓ No 4 SKIP to Item 3,26. 3.25 Provide details of any toxicity reduction evaluations conducted. 3.26 Have you completed Table E for all applicable outfalls and attached the results to the application package? ❑ Yes Not applicable because previously submitted information to the NPDES sermittin. authorit . SECTION 4. INDUSTRIAL DISCHARGES AND HAZARDOUS WASTES(40 CFR 122.21(j)(6)and(7)) 4.1 Does the POTW receive discharges from Sills or NSCIUs? ❑ Yes ❑✓ No 4 SKIP to Item 4.7. Q, 4.2 Indicate the number of Skis and NSCIUs that discharge to the POTW. Number of SIUs Number of NSCIUs 0 4.3 Does the POTW have an approved pretreatment program? i° ❑ Yes ❑ No 2 4.4 Have you submitted either of the following to the NPDES permitting authority that contains information substantially identical to that required in Table F: (1)a pretreatment program annual report submitted within one year of the as application or(2)a pretreatment program? 0 Yes ❑ No 4 SKIP to Item 4.6. 0 6 4.5 Identify the title and date of the annual report or pretreatment program referenced in Item 4.4.SKIP to Item 4.7. C C — 4.6 Have you completed and attached Table F to this application package? ❑ Yes ❑ No EPA Form 3510-2A(Revised 3-19) Page 9 EPA Identification Number NPDES Permit Number Facility Name Form Approved 03/05/19 NC0086924 Tyrrell County RO WTP Bull's Bay OMB No.2040-0004 4.7 Does the POTW receive,or has it been notified that it will receive, by truck, rail,or dedicated pipe, any wastes that are regulated as RCRA hazardous wastes pursuant to 40 CFR 261? ❑ Yes ✓❑ No 4 SKIP to Item 4.9. 4.8 If yes,provide the following information: Annual Hazardous Waste Waste Transport Method Amount of Units Number (check all that apply)PP Y) Waste Received ❑ Truck ❑ Rail ❑ Dedicated pipe ❑ Other(specify) -40 w ❑ Truck ❑ Rail ❑ Dedicated pipe ❑ Other(specify) 0 ct, ❑ Truck ❑ Rail _ ❑ Dedicated pipe ❑ Other(specify) m R 4.9 Does the POTW receive,or has it been notified that it will receive, wastewaters that originate from remedial activities, y including those undertaken pursuant to CERCLA and Sections 3004(7)or 3008(h)of RCRA? ❑ Yes ❑✓ No 4 SKIP to Section 5. 3 4.10 Does the POTW receive(or expect to receive)less than 15 kilograms per month of non-acute hazardous wastes as specified in 40 CFR 261.30(d)and 261.33(e)? ❑ Yes 4 SKIP to Section 5. ❑ No 4.11 Have you reported the following information in an attachment to this application: identification and description of the site(s)or facility(ies)at which the wastewater originates;the identities of the wastewater's hazardous constituents;and the extent of treatment, if any,the wastewater receives or will receive before entering the POTW? ❑ Yes ❑ No SECTION 5.COMBINED SEWER OVERFLOWS(40 CFR 122.21(j)(8)) E 5.1 Does the treatment works have a combined sewer system? ❑ Yes 0 No -*SKIP to Section 6. co i3 5.2 Have you attached a CSO system map to this application?(See instructions for map requirements.) ❑ Yes ❑ No co 0 5.3 Have you attached a CSO system diagram to this application?(See instructions for diagram requirements.) c-'co ❑ Yes ❑ No EPA Form 3510-2A(Revised 3-19) Page 10 EPA Identification Number NPDES Permit Number Facility Name Form Approved 03/05/19 NC0086924 Tyrrell County RO WTP Bull's Bay OMB No.2040-0004 5.4 For each CSO outfall, provide the following information. (Attach additional sheets as necessary.) CSO Outfall Number CSO Outfall Number CSO Outfall Number = City or town 0 •2- State and ZIP code U CD 0 County w o o o o Latitude 0 co Longitude " Distance from shore ft. ft. ft. Depth below surface ft. ft. ft. 5.5 Did the POTW monitor any of the following items in the past year for its CSO outfalls? CSO Outfall Number CSO Outfall Number CSO Outfall Number Rainfall ❑ Yes 0 No 0 Yes ❑ No 0 Yes ❑ No 0) .`o CSO flow volume ❑ Yes ❑ No 0 Yes 0 No 0 Yes 0 No 0 CSO pollutant o concentrations ❑ Yes ❑ No 0 Yes 0 No ❑ Yes CI No cn (..) Receiving water quality ❑ Yes 0 No 0 Yes ❑ No ❑ Yes ❑ No CSO frequency ❑ Yes 0 No ❑ Yes ❑ No 0 Yes ❑ No Number of storm events ❑ Yes ❑ No 0 Yes 0 No 0 Yes ❑ No 5.6 Provide the following information for each of your CSO outfalls. CSO Outfall Number CSO Outfall Number CSO Outfall Number } Number of CSO events in events events events y the past year a = Average duration per hours hours hours event ❑Actual or 0 Estimated 0 Actual or 0 Estimated 0 Actual or 0 Estimated "' million gallons million gallons million gallons o Average volume per event o 0 Actual or 0 Estimated 0 Actual or 0 Estimated 0 Actual or 0 Estimated Minimum rainfall causing inches of rainfall inches of rainfall inches of rainfall a CSO event in last year 0 Actual or 0 Estimated 0 Actual or 0 Estimated 0 Actual or 0 Estimated EPA Form 3510-2A(Revised 3-19) Page 11 EPA Identification Number NPDES Permit Number Facility Name Form Approved 03/05/19 NC0086924 Tyrrell County RO WTP Bull's Bay OMB No.2040-0004 5.7 Provide the information in the table below for each of your CSO outfalls. CSO Outfall Number CSO Outfall Number CSO Outfall Number Receiving water name Name of watershed/ stream system U.S. Soil Conservation ❑ Unknown ❑ Unknown 0 Unknown Service 14-digit watershed code > (if known) Name of state re management/river basin U.S. Geological Survey 0 Unknown 0 Unknown 0 Unknown 8-Digit Hydrologic Unit Code(if known) Description of known water quality impacts on receiving stream by CSO (see instructions for exam.les SECTION 6.CHECKLIST AND CERTIFICATION STATEMENT(40 CFR 127.22(a)and(d)) 6.1 In Column 1 below,mark the sections of Form 2A that you have completed and are submitting with your application. For each section, specify in Column 2 any attachments that you are enclosing to alert the permitting authority. Note that not all applicants are required to provide attachments. Column 1 Column 2 ❑ Section 1: Basic Application ❑ w/variance request(s) ❑ w/additional attachments Information for All Applicants ✓❑ Section 2:Additional ✓❑ w/topographic map ❑✓ w/process flow diagram Information ✓❑ w/additional attachments ✓❑ wl Table A ❑✓ w/Table D ❑ Section 3: Information on 0 w/Table B ❑ w/Table E • Effluent Discharges ❑ w/Table C ❑ w/additional attachments cri Section 4: Industrial ❑ w/SIU and NSCIU attachments ❑ w/Table F ❑ Discharges and Hazardous a Wastes ❑ w/additional attachments Section 5: Combined Sewer ❑ w/CSO map ❑ w/additional attachments ❑ Overflows ❑ w/CSO system diagram Section 6: Checklist and Certification Statement ❑ w/attachments Y 6.2 Certification Statement U I certify under penalty of law that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fine and imprisonment for knowing violations. Name(print or type first and last name) Official title David L.Clegg COUNTY MANAGER ignature Date signed 1' sQl / isD- - EPA Form 3510-2A(Revised 3-19) Page 12 EPA Identification Number NPDES Permit Number Facility Name Outfall Number NC0086924 Tyrrell County R0 WTP Bull's Bay 001 TABLE A.EFFLUENT PARAMETERS FOR ALL POTWS Maximum Daily Discharge Average Daily Discharge Pollutant Number of Value Units Value Units Samples Biochemical oxygen demand 0 BOD5 or 0 CBOD5 not measured (report one) Fecal coliform not measured Design flow rate 0.087 MGD 0.065 MGD 1721 pH(minimum) 6.69 su pH(maximum) 8.88 su Temperature(winter) not measured Temperature(summer) not measured Total suspended solids(TSS) not measured 1 Sampling shall be conducted according to sufficiently sensitive test procedures(i.e., methods)approved under 40 CFR 136 for the analysis of polluti required under 40 CFR chapter I,subchapter N or 0. See instructions and 40 CFR 122.21(e)(3). EPA Form 3510-2A(Revised 3-19) EPA Identification Number NPDES Permit Number Facility Name Outfall Number NC0086924 Tyrrell County RO WTP Bull's Bay TABLE B. EFFLUENT PARAMETERS FOR ALL POTWS WITH A FLOW EQUAL TO OR GREATER THAN 0.1 MGD Maximum Daily Discharge Average Daily Discharge Pollutant Number of Value Units Value Units Samples Ammonia(as N) 22 mg/L 14.97 mg/L 76 Chlorine (total residual,TRC)2 not measured Dissolved oxygen 18.9 mg/L 8.07 mg/L 395 Nitrate/nitrite not measured Kjeldahl nitrogen not measured Oil and grease not measured Phosphorus 2.44 mg/L 1.14 mg/L 29 Total dissolved solids 13970 mg/L 11946 mg/L 66 Sampling shall be conducted according to sufficiently sensitive test procedures(i.e., methods)approved under 40 CFR 136 for the analysis of pollute required under 40 CFR chapter I,subchapter N or 0. See instructions and 40 CFR 122.21(e)(3). 2 Facilities that do not use chlorine for disinfection, do not use chlorine elsewhere in the treatment process, and have no reasonable potential to disch2 required to report data for chlorine. EPA Form 3510-2A(Revised 3-19) EPA Identification Number NPDES Permit Number Facility Name Outfall Number NC0086924 Tyrrell County RO WTP Bull's Bay TABLE D.ADDITIONAL POLLUTANTS AS REQUIRED BY NPDES PERMITTING AUTHORITY Maximum Daily Discharge Average Daily Dischar e Pollutant Number of (list) Value Units Value Units Samples ❑ No additional sampling is required by NPDES permitting authority. Salinity 15.1 ppt 11.41 ppt 66 Conductivity 27200 umhos/cm 19589 umhos/cm 66 Turbidity 24 ntu 3.33 ntu 56 Total Chloride 12500 mg/L 6576 mg/L 66 Total Copper 27 ug/L 6 ug/L 66 Total Zinc 173 ug/L 41.5 ug/L 66 Total Nitrogen 24.64 mg/L 15.89 mg/L 24 1 Sampling shall be conducted according to sufficiently sensitive test procedures(i.e., methods)approved under 40 CFR 136 for the analysis of pollute under 40 CFR chapter I, subchapter N or 0. See instructions and 40 CFR 122.21(e)(3). EPA Form 3510-2A(Revised 3-19) , X\ \ W \�, \ \,Foul �\ - j Foul=` ~ L,\,\O Y .. sg ;!'� B U L L B A Y I / z / •I Ii off. .... Bunton 2 (C) I1 \Ily2 : _ _ --/_' Col! II Foul _ 11:74: f ;` 1 � (II .11 X/' `_/ , '1 �1r ✓,6,� Outfall ,� s i"„ i rf / I .,-�: v It i - t, ' Bull's Bay RO Water ti . ; wo) _ f. J y; ; Treatment Plant ;, --r-__ Q '' l ''N I , j a r ems. 0'i ` \ �. I , -.%.,.._ I I ,i \ P. .. New Jerusalem �.j�,__ v !_ L� _• • \ - — A.D.• (--).a i-I.) -,•"--1 s., , 1 . (\--:::....., ,. . Tyrrell County N Reverse Osmosis WTP NPDES Permit NC0086924 A . . / Receiving Stream: Bull Bay Stream Class:SB Failitn Location Stream Segment: 30-14 Sub-Basin II:03-01-53 scaale not shown River Basin: Pasquotank HUC:301020502 SCALE 35.93778°,-76.35500° County:Tyrrell 1:24,000 USGS Quad:Columbia West to 1 r *x - . 1 - _ , .. ''tom- yA y...-. , 2 f Instream sampling ' location M6 Instream sampling location B V ILI I . 17 •1 " •• • , „ . . . . . . i,.. s • . I. 6.1 • ..�`� �F _ s f i ` Y a. (�.. w ter..-.,*- r \ .gam .3 . Instream Monitoring Requirements Tyrrell County Re NPDES Permit NC Tyrrell County Bull's Bay Reverse Osmosis Water Treatment Plant . . . . _ . • _. f"- .� _ •-• .,..- i r� . • ' . _ • . -- . . - .. , • ,� ,. •`"' Finished water Pumps •_ ....'.. • -_ -- • 'U Cleaning Tank Raw Water '61. `. „ >Supply Well „ , µ .. -mom r . f g, :,•,,i1:;t'„Z'J-11-,:-.,;;.,.'-„-:",:- %-7',';:-77,-,,":11.'','‘-• :i71=,:I.:,-.‘''''-' .-.C-i",.-,:i.;-.41,t4;''';/: ;•'-,-,-,:.l'-: i40,','P''•''.A-.'.'-'-'.,::'•• .W.-','''.1''. ''''-'--.;'-'i 'i ..--' :' ;;'1*-4ef' 4116,,, . ".<t $ ""IF.- -- .ti+ a*"Y 5 - e4 q +4.4•4•- f�r • .w-1 • (., iff 1' , 't i"p• +� $ _ .. ky .iF y f 1.�. -I '•' e'�, t'.^,'er F rr._',...-. y v '' '''' `-'y, . 7 .- ' ir. tv a ,r er ' yv y' . . S. ..t- ��s!rfY% ' fa ,r r , _ `-c Yl!I .. O, R e ,•" rt. ; L S ` t.i fof ' fi`.ss"j �C , A`�_ fasp� vim- a ., Y 4 •••4 . 3K r '' iT 4y- S•R''ca. = , 44`Af ' . - ; , c om+ • • 4 .Google Earth .t: a , - .%.. . y � . ,� . . Tyrrell County Bull's Bay NC0085924 Reverse Osmosis Process Flow Diagram Reverse Osmosis Train A single train is comprised of membranes, tanks, pumps, pressure regulators, mixing valves, safety valves, and instruments necessary to make briny aquifer water potable. The RO unit is constructed by equipment suppliers and delivered to the municipality. Feed Water 1.000 MGD Well Pump(s) r Aq uifer my