Loading...
HomeMy WebLinkAboutNCC223150_Site Plan or Location Map_20220908w 0 w z 0 U z 0 0 w w U w Iw a 0 E I� CD U al N 0 N N cn U i w / c� 0 / N 0 N / 0 Q c- / N 0 0 m N 0 N / 0 w SOUTHERN PINES, N.C. VICINITY MAP(1"=2000') o GRADING / EROSION CONTROL NOTES 0 INSTALL CONSTRUCTION ENTRANCE (SEE TOSP DETAIL E3) 0 INSTALL SILT FENCE (SEE TOSP DETAIL E6) 0 INSTALL SILT FENCE OUTLET (SEE TOSP DETAIL E7) 0 INSTALL TEMPORARY SEDIMENT TRAP (SEE CDC DETAIL 2.1605) 0 INSTALL FAIRCLOTH SKIMMER (SEE CDC DETAIL 2.1607) AND POROUS BAFFLES (SEE CDC DETAIL 2.1602) 0 INSTALL HARDWARE CLOTH & GRAVEL INLET PROTECTION (SEE TSOP DETAIL E4) ADDITIONAL NOTES 11 12 13. r ALL GENERAL NOTES, ABBREVIATIONS, SYMBOLS, AND OTHER INFORMATION INDICATED ON COVER SHEET SHALL APPLY TO THIS PLAN ALL ELEVATIONS SHOWN ARE IN REFERENCE TO THE BENCHMARK AND MUST BE VERIFIED BY THE GENERAL CONTRACTOR WITH THE SURVEYOR OF RECORD PRIOR TO BEGINNING CONSTRUCTION. BENCHMARK IS AN EXISTING CONCRETE MONUMENT LOCATED AT THE NE CORNER OF THE PROJECT AND IS 52.5 FEET SOUTH-SOUTHEAST OF THE CENTER OF INTERSECTION AT S BENNETT ST. AND W WISCONSIN AVE., WITH COORDINATES N 517378.89, E 1880601.99 AND HAVING AN ASSUMED ELEVATION OF 494.31. PURSUANT TO G.S.113A-57(2), THE ANGLE FOR GRADED SLOPES AND FILLS SHALL BE NO GREATER THAN THE ANGLE THAT CAN BE RETAINED BY VEGETATIVE COVER OR OTHER ADEQUATE EROSION CONTROL DEVICES OR STRUCTURES. IN ANY EVENT, SLOPES LEFT EXPOSED WILL, WITHIN 7 or 14 CALENDAR DAYS OF COMPLETION OF ANY PHASE OF GRADING, BE PLANTED OR OTHERWISE PROVIDED WITH TEMPORARY OR PERMANENT GROUND COVER, DEVICES OR STRUCTURES SUFFICIENT TO RESTRAIN EROSION. PURSUANT TO G.S. 113A-57(3), PROVISIONS FOR PERMANENT GROUND COVER SUFFICIENT TO RESTRAIN EROSION MUST BE ACCOMPLISHED FOR ALL DISTURBED AREAS WITHIN 15 WORKING DAYS OR 90 CALENDAR DAYS (WHICHEVER IS SHORTER) FOLLOWING COMPLETION OF CONSTRUCTION OR DEVELOPMENT. ALL SEEDED AREAS WILL BE FERTILIZED, RE -SEEDED AS NECESSARY, AND MULCHED ACCORDING TO SPECIFICATIONS IN THE VEGETATIVE PLAN TO MAINTAIN A VIGOROUS, DENSE VEGETATION COVER. IF ANY SEEDING FAILURE OCCURS, THOSE AREAS SHALL BE RE -SEEDED WITH RYE GRAIN FOR TEMPORARY STABILIZATION AND PREPARED FOR PERMANENT SEEDING. SEE DETAIL SHEETS FOR EROSION CONTROL MEASURES & MAINTENANCE. CONTACT PERSON: KEVIN LINDSAY, CRAWFORD DESIGN CO. (910)-725-1107 PARCEL IDENTIFICATION NUMBER(S): 20190227 - 858100075283 CONTRACTOR SHALL REMOVE TEMPORARY EROSION CONTROL MEASURES ONLY AFTER REMOVAL HAS BE APPROVED BY NCDEQ. CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING EROSION AND SEDIMENTATION CONTROL MONITORING ACCORDING TO NPDES PERMIT REQUIREMENTS. SEE SHEET C 5.0 FOR TEMPORARY & PERMANENT SEEDING REQUIREMENTS. EROSION CONTROL CONSTRUCTION SEQUENCE 1. OBTAIN ALL NECESSARY PERMITS AND APPROVALS AND HOLD PRE -CONSTRUCTION CONFERENCE. 2. INSTALL GRAVEL CONSTRUCTION ENTRANCE. 3. INSTALL TEMPORARY SEDIMENT FENCE AND FENCE OUTLETS. 4. CLEAR AND GRUB 5. INSTALL TEMPORARY SEDIMENT TRAP W/ POROUS BAFFLES AND SKIMMER. 6. INSTALL STORM DRAINS AND INLET PROTECTION. 7. COMPLETE SITE WORK AND STABILIZE ALL AREAS UPSTREAM OF SEDIMENT TRAP. 8. REMOVE SEDIMENT TRAP 9. INSTALL PERMEABLE PAVER SYSTEM ONLY AFTER UPSTREAM AREAS ARE STABILIZED. DWQ Construction General Permit Ground Stabilization Requirements Site Area Stabilization StabilizationTime Description Time Frame Frame Exceptions Perimeter dikes, swales, 7 days None ditches and slopes High Quality Water (HQW) 7 days None or less in length Slopes steeper 7 days and are not than 3:1 steeper than 2:1, 14 days Slopes 3:1 or 14 days slopes greater flatter than 50 feet in All other areas for perimeters with slopes 14 days and HQW flatter than 4:1 * "Extensions of time may be approved by the permitting authority based on weather or other site -specific condition that make compliance impracticable." (Sectio 11.13(2)(b)) EGG --oE----oE----oE- og----oE----oE----of-- -�oE--oE----oE- -OE oE----oE---- OE: ----oE----oE----NE--\ of oE----oE----o�----oE----oE----oE----oE----of----of----of--- of----oE4 ---I o v oE-_-oE----oE--I of--- �� SSMH CI#3 _,��' I I�� qE--- �oE- f ------------- �e -- RIM:499.65 - - ` = _ \ S.R.2035 \ ---- 'TOP=497.60 ------ - SSMH \ -of----oE / So INV IN:492.08' \ \ INV.=493.05 Concrete Pipe 15" IN -SE 111,9 0 RIM:494.56' F, � 1 0= S. BENNETT ST. � ( p )s I I - ° o A INV OUT: 491.99' (50' PUBLIC R.O.W.) �0�� INV.=493.o5(Concrete PipeCI #�"oUT-N) INV IN:487.12 e, \ 1 INV OUT: 487.00 �\ / CI #4 _ - - TOP=496.00 � I E' I I ,oe\ j o / TOP=497.60 / INV.=492.93 (Concrete Pipe 15" IN-S) ,\\o / �_LOC�/LOC LOC INV.=494.25 (Concrete Pipe 15" OUT -SE) / INV.=492.93 (Concrete Pipe 15" OUT -NE F _ ioc- ----Lac - °o %------- -- LOC LOC / �--- ---- -- --- -- --- / OE - --OE --- � '-� - -- - ---of----of----0 ---- I � ' n - - - SF ---� SF 0 / 56.81 FF 15-FRCP C I #1 F F SF,SF SF F �-@ p.49� TOP=494.60 --- 15" RCP @ 0.49% SF49INV.=492.65 (ConcretePipe 15" IN-SW)>�--SD---SD----SD---- ---THE T N DE sO- �T�N ECI#55469 - 2 - PETTY PROPERTY GROUP, LLC� TOP=498.074961 - 545 INV.=494.06 (Concrete Pipe 15" IN -NW) o PC: 11 - SL: 523 S� INV.=494.06(ConcretePipe15"OUT-SE) �, / BENCHMARK __ ZONE CB FFE °' CD / o ECM / / FFE FFE FFE / oU FFE ELEV=494.31 / i / 1 / 500.50 500.50 500.50 s� \ FFE r 0 0 ` N 517378.8897 I 1 I I V I 5 00 / 500.00 � ��� � - - 499.00 0 / E 1880601.9877 J co 2" FAIRCLOTH SKIMMERWITH1.�S- ORIFICE I \ \ (CONNECTION SKIMMER TO -EXISTING STORM DRAIN UNDER WISCONSIN AVE. FFE i = 499.00 V I f SDMH #11 _ \ o co PATRICIA RICHARDSON I \ i TOP=498.24 O_ Q? 4446 - 51 1 I INV.=493.27 (Concrete Pipe 15" OUT -NW) PC: 6- SL: 256 E PC: 11 - SL: 523 I I C - I / I ZONE CB I 9. 0( I I( I � nv � �U Z FFE r I 0 Z V I' II / I 1.0 4\6 \\ of § y \ \ \ s� II < ROBERT E SHENKLE�I 2 I'T1 l II I I I I 3478 - 202 - PC: 11 - 523 FFE o V A I I I ZONE: CB I 500.50 FFE 499.50 I FFE 92.56 LF 15" RCP @ 0.50% j �� V A I \ 01 500.50 ° UNDERGROUND SCM 1 (SEE DETAILHEET) 499 \ 19 1 0 I I 1 I I I 1 \ i FFE I i - 8.34 LF 15" RCP @ 1.00% 0 ROBERT E SHENKLE 500.50 S� -`- 2698 - 161 / �'�� - - - FFE PC: 11 - 523 -' i- 500.501 o'n I0 \ V I I I I ZONE CB 9 , A \ 0 - - �� SDj r� ---------------- Din 18" NON -TRAFFIC LANDSCAPE DI #9 SDMH #10 0 \ \ \ \ TOP=498.82 18" NON -TRAFFIC LANDSCAPE DI #8 \ TOP=499.00 FFE \ \ \ \ \ \ TOP=499.50 I \ \ INV.=497.80 (PVC Pipe 6" OUT -NE) � ----------- INV.=497.28 (PVC Pipe 6" IN -SW) INV.=493.46 (Concrete Pipe 15" IN -SW) SUMP INV=492.46 50050 \ \ I INV.=497.28 (PVC Pipe 6" OUT -NE . INV OUT=493.30 (24" HDPE) DI#7 1 \ \ 1 J \ I \ TOP=498.85 / INV.=493.54 (Concrete Pipe 15" IN -NW) INV.=496.85 (PVC Pipe 6" IN -SW) 2.0% FFE \ INV.=493.54 (Concrete Pipe 15" OUT-. o \ --�IId ' 500.50 D \ I \ I I \ I FFEv o r --- Soo 500 500.50 'gs9-, I`9� Z„ I� I _j A I \o \\ 685 S BENNETT STREET, FFE " 4g9 \ 3910 - 284 I I \ w \ I PCB 10 - SL: 998 501.00 ZONE: CB o I \ FFE 501.00 f v \ \ A I I I I --- V \ - - - J 501- - / / 498- \ owl - / / PTAH, / 5595 - 535 / PC: 18 - SL: 279 A V A I Temporary Sediment Trap Dimensions (TST) TST # Side Trap Trap Top Dims. ft Surface Trap Weir (ft) Sloe Depth ft Height ft Width Length Area sf Volume Length Height 1 2 3 4.5 28 56 1,568 3,300 6 1.5 Landscape Architecture ♦ Fayetteville, NC Civil Engineering ♦ Southern Pines, Nc 116 N. Cool Spring Street ♦ Fayetteville, NC 28301 Voice:910-221-0033 ♦ Fax:910-221-0035 w w w. c r a w f o r d d s n. c o m ,,,gyp/I11111/II�j ,,��IIIIIIIII/III v: :Q Z Z 1 CERT. No. c C CERT. No. c C C-136 C-2097 i ZC ?P �I� 2�RTti CARS �P ��� I� NTH C"'C" ,,,,,,, ,,,,7* rEV 11-0- III IIIINI�p,,,, 11111,,,, SEALS A SEAL 027502 GiNe 1.1� �x` •LZ f1(111111,L:_,(y FOR CONSTRUCTION REVISIONS Him I L1J Z Z L1J m Z Q O (A J O L1J O Z o J = U J oZ Z o U) LLJ Z O 0// LL m PROJECT DETAILS Project Manager: KSL CAD Technician: RFN/CER Reviewed / Approved By: Project Number: 21027 SCALE 0 20 40 Omni Full Scale: Horiz.: 1" = 20' Half Scale: Horiz.: 1" = 40' ISSUE DATE 11 /15/2021 SHEET NUMBER C 3,0 U I